REVIEWED RESPONSE 1 BLD-BLD2024-1470+12.12.2024_4.40.51_PM+4668065RESUB REVIEWED °oeEPAmmZOZ45 BY Al CITY OF EDMONDS D) D J ALEXANDRA IMMEL RESIDENTIAL DESIGN Deck PERMIT: Project # BLD2024-14470 OWNER: Molly Jenkins 18914 94th Ave W. Edmonds, WA 98020 December 12, 2024 Dear Marissa Rutler, Please see the below responses to your comments - 1. Per 2021 IRC section R308.4.2 safety glazing is required near doors. Please update plans as needed and resubmit for review. Response: the exterior elevations have been updated to show tempered glass at the new windows and door, following the window/door schedule. See sheet AA3.2. 2. Please clarify new work versus existing on the floor plan and roof plan. It appears there is a new bathroom, new powder room, and new roof; this could be a hangover from the previous work completed under a different permit. Response: This was inadvertently not updated from the previous work under a different permit. The text has been corrected, see updated sheets A2.2, A3.1 & A3.2. 3. Indicate required flashing at a proposed pressure treated ledger board. Response: See updated detail 3/A4.1. Please let me know if you have any questions. Thank you, Tracy L. Ronaldson, for AIRD 5306 BALLARD AVE NW #225 SEATTLE WA 98107 • 206.501.3038 • ADMINQALEXANDRAIMMELDESIGN.COM • ALDCANDRAIMMELDESIGN.COM b2structural engineers JENKINS DECK ADDITION 18914 94TH AVE WEST. EDMONDS, WA 98020 STRUCTURAL DESIGN PROJECT NO: 24260 DATE:12/11/24 PREPARED BY: BASRI BASRI PE, SE n Criteria International Building Code (IBC) 2021 American Society of Civil Engineers (ASCE) 7-16 RESPONSE TO STRUCTURAL COMMENTS 4. Knee braces are required on posts greater than 4 feet in height. RESPONSE: PER CONVERSATION WITH DONOVAN AKAU, THE KNEE BRACES ARE NOT REQUIRED SINCE THE DECK IS SMALL AND LATERALLY BRACED BY THE HOUSE ON TWO SIDES 5. Indicate hold-down or tension device on plans. RESPONSE: PER CONVERSATION WITH DONOVAN AKAU, HOLDOWN OR TENSION DEVICES ARE NOT REQUIRED SINCE THE DECK IS SMALL AND LATERALLY BRACED BY THE HOUSE ON TWO SIDES 6. It appears the proposed footings do not align with the recommendations outlined in the submitted geotechnical report. Refer to page 12 for minimum lateral dimensions of column footings and allowable soil bearing pressure. Please correct as required and resubmit for review. RESPONSE: PLEASE SEE ATTACHED EMAIL BY THE GEOTECH STATING THAT THE LATERAL DIMENSIONS OF THE FOOTING CAN BE 18 INCH (MATCHING WHAT SHOWN IN THE STRUCTURAL DRAWINGS). PLEASE ALSO SEE ATTACHED CALCULATIONS OF FOOTING USING 2000 PSF ALLOWABLE BEARING PRESSURE YIELDING 18 INCH WIDE ROUND FOOTING. 7. Provide details and indicate all framing members required to reframe the rough opening for the proposed door and side lites. Indicate all fasteners and hardware required for positive connections at the base and top of fenestration opening. Demonstrate the proposed opening and framing will not compromise the existing lower -level framed wall and foundation. RESPONSE: PLEASE SEE DETAIL 4 OF S-1 SHOWING ELEVATION FOR OPENING FRAMING. PLEASE ALSO SEE PLAN 2/S-1 SHOWING ADDITIONAL NOTES FOR OPENING FRAMING REVISED FOOTING DIMENSION RECOMMENDATION BY THE GEOTECH Re: Fw: Jenkins recommendations { Q li�? 8 ili G OAdam Gaston <agaston@geogroupnw.com> Tue, Dec 10, 7:35 AM To: basri, Tracy Ronaldson, Bill Chang Hi Basri, An 18-inch diameter or 18" x 18" size footing is acceptable provided it is constructed on top of the competent (medium dense to dense) glacial till or compacted structural fills placed on top of the competent till. Thanks, Adam Adam Gaston Project Engineer GEO Group Northwest o:425-649-8757 m: 425-802-3199 e: agastonCgeogroupinv.com Show original message UPDATED FOOTING CALCULATIONS USING 2000 PSF ALLOWABLE SOIL BEARING PRESSURE Project: Jenkins Deck Location: F-1 Footing Footing [2021 International Building Code(2018 NDS)] Footing Size: 1.5 FT Round Diameter X 10.00 IN Deep Reinforcement: #4 Bars @ 9.00 IN. O.C. E/W / (2) min. Section Footing Design Adequate FOOTING PROPERTIES Ar Allowable Soil Bearing Pressure: Qs = 2000 psf Concrete Compressive Strength: F'c = 2500 psi Reinforcing Steel Yield Strength: Fy = 40000 psi Concrete Reinforcement Cover: c = 3 in FOOTING SIZE Diameter: Dia. = 1.5 ft Effective Depth to Top Layer of Steel: d = 6.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m = 4 in Column Depth: n = 4 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu = 1811 psf Effective Allowable Soil Bearing Pressure: Qe = 1875 psf Required Footing Area: Areq = 1.71 sf Area Provided: A = 1.77 sf Baseplate Bearing: Bearing Required: Bear = 5120 lb Allowable Bearing: Bear -A = 44200 lb Beam Shear Calculations (One Way Shear): Beam Shear: Vu1 = 554 lb Allowable Beam Shear: Vc1 = 7478 lb Punching Shear Calculations (Two Way Shear): Critical Perimeter: Bo = 41 in Punching Shear: Vu2 = 3006 lb Allowable Punching Shear (ACI 11-35): vc2-a = 57656 lb Allowable Punching Shear (ACI 11-36): vc2-b = 77813 lb Allowable Punching Shear (ACI 11-37): vc2-c = 38438 lb Controlling Allowable Punching Shear: vc2 = 38438 lb Bending Calculations: Factored Moment: Mu = 10209 in -lb Nominal Moment Strength: Mn = 85082 in -lb Reinforcement Calculations: Concrete Compressive Block Depth: a = 0.46 in Steel Required Based on Moment: As(1) = 0.05 in2 Min. Code Req'd Reinf. Flex. Members (ACI-150.1): As(2) = 0.32 in2 Controlling Reinforcing Steel: As-reqd = 0.32 in2 Selected Reinforcement: #4's @ 9.0 in. o.c. e/w (2) Min. Reinforcement Area Provided: As = 0.39 in2 Development Length Calculations: Development Length Required: Ld = 15 in Development Length Supplied: Ld-sup = 4.98 in Note: Plain concrete adequate for bending, therefore adequate development length not required. page BASRI BASRI B2 ENGINEERS StruCalc Version 11.1.8.0 12/9/2024 5:04:16 PM or LOADING DIAGRAM �4in� 10 in C� C� T 3 in T 1.5 ft FOOTING LOADING Live Load: PL = 3200 lb Dead Load: PD = 0 lb Total Load: PT = 3200 lb Ultimate Factored Load: Pu = 5120 lb Footing plus soil above footing weight: Wt = 142 lb