APPROVED BLD BLD2024-0257+Structural_Plan+3.15.2024_11.48.05_AM+4137848■ monsoons monsoons monsoons monsoons monsoons ■■■■■■r THE FOLLOWING DOCUMENTATION SHALL BE ; : AVAILABLE ON SITE FOR THE BUILDING INSPECTOR: ; PROJECT SPECIFIC DESIGN CRITERIA : ,5�OE APPROVED ARCHITECTURAL PLAN SET Wind Design Data VCOE APPROVED STRUCTURAL PLAN SET ; ---------------------------------------------------------- ' COE REVIEWED CALCULATION PACKET Wind Design Speed, Vu = 110 MPH, Vasd = 85 MPH Wind Exposure = B : ENERGY CREDIT WORKSHEET Wind Importance Factor, Iw = 1.0 Internal Pressure Coefficient 0.18 ■ SITE PLAN = +/- Ktz = 1.00 ' CIVIL PLAN Kd = 0.85 Seismic Design Data : n ; Importance factor = 1.0 Ss = 1.27g, S1 = 0.49g ; CITY OF EDMONDS BUILDING DEPARTMENT 2021 ; Site Class = D ............................................... SIDS = 1.01 g, SD1 = 0.60g SDC = D Seismic System = 15. Light -frame (wood) walls sheathed with wood structural panels rated for shear resistance Design Base Shear = 17.02 kips Cs = 0.156 R=6.5 Analysis procedure: ASCE 11.4, 11.5 & 12.8 Snow Loads Flat -roof snow load, pf = 25.0 psf Snow exposure factor, Ce = 1.00 Snow load important factor, Is = 1.00 Thermal factor, Ct = 1.00 Gravity Loads* Roof Dead Load = 15 psf + 5 psf (SOLAR PANELS) Roof Live Load = 25 psf Floor Live Load (Office) = 50 psf Floor Live Load (Residential) = 40 psf, Balcony & Roof Decks = 60 psf Floor live Load (Corridor) = 100 psf Partition Loads = 10 psf (residential) Partition Loads = 20 psf (office) Floor Dead Loads = 12 psf (residential) At rest earth pressure = 60 pcf *As Applicable GENERAL 1. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE 2018 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC). 2. THE ARCHITECT/ENGINEER (ARCH/ENGR) IS NOT RESPONSIBLE FOR THE LOCATION OF PROPERTY LINES AND/OR EASEMENT, SOIL CONDITIONS, MECHANICAL AND ELECTRICAL WORK, AND THE PRESENCE OF UTILITIES NOT REPORTED TO THE ARCH/ENGR IN WRITING BY THE OWNER. 3. THE ENGINEER IS NOT RESPONSIBLE FOR FIELD REVIEW OF CONSTRUCTION UNLESS SPECIFICALLY RETAINED FOR THAT PURPOSE. 4. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 5. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. CONTRACTOR SHALL COMPARE THE DRAWINGS AND NOTIFY THE ARCH/ENGR OF ANY DISCREPANCIES PRIOR TO COMMENCING WITH THE WORK. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM HIS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 8. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 9. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. 10. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. GEOTECHNICAL 11. GEOTECHNICAL FOUNDATION NOTES: SUBGRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, COMPACTION, AND FILLING REQUIREMENTS, SHALL CONFORM STRICTLY WITH RECOMMENDATIONS GIVEN IN THE SOILS REPORT OR AS DIRECTED BY THE SOILS ENGINEER. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL OR BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (OR IN DETAILS) ARE MINIMUM AND FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD WORKING WITH THE TESTING LAB AND SOILS ENGINEER. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE AS NOTED IN THE SOILS REPORT. IN THE ABSENCE OF A SOILS REPORT THE FOLLOWING VALUES ARE USED: ALLOWABLE SOIL PRESSURE 2,000 PSF LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) 55 PCF/35 PCF LATERAL EARTH PRESSURE (SEISMIC) 8H (ULTIMATE LOAD) PASSIVE EARTH PRESSURE (INCLUDES FACTOR OF SAFETY = 1.5) 350 PCF COEFFICIENT OF FRICTION (INCLUDES FACTOR OF SAFETY = 1.5) 0.35 SOILS REPORT REFERENCE: (N/A) GENERAL STRUCTURAL NOTES: CONCRETE 12. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH ACI 318-14 AND ACI 301-10. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH (f'c) OF 3000 PSI, SHALL CONTAIN NO LESS THAN 5-1/2 SACKS OF CEMENT, HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.45, AND A SLUMP OF 5 INCHES OR LESS. CONCRETE HAS BEEN DESIGNED BASED ON A CONCRETE STRENGTH (f'c) OF 2500 PSI PER SEATTLE BUILDING CODE SECTION 1705.3 EXCEPTION 2.3 TO AVOID SPECIAL INSPECTIONS AND MATERIAL TESTING. 13. PERFORMANCE MIX DESIGNS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX DESIGN SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE (3/4" MAXIMUM), WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATIO, SLUMP, TARGET CONCRETE STRENGTH. SUBSTANTIATING STRENGTH DATA CONFORMING TO CURRENT ACI AND ASTM STANDARDS SHALL BE SUBMITTED WITH THE PERFORMANCE MIX DESIGN. THE USE OF A PERFORMANCE MIX REQUIRES BATCH PLANT INSPECTION, THE COST OF WHICH SHALL BE PAID BY THE GENERAL CONTRACTOR. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. 14. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494M, AND C618. UNLESS OTHERWISE NOTED THE TOTAL AIR CONTENT SHALL BE 5%. AIR CONTENT SHALL BE SAMPLED IN ACCORDANCE WITH ASTM C172 ABD ARI CONTENT MEASURED IN ACCORDANCE WITH ASTM C231 OR C173. 15. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENTS S1), GRADE 60, Fy = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 16. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI SP-66-04 AND ACI 318-14 CHAPTER 25. UNLESS OTHERWISE NOTED LAP REINFORCEMENT A MINIMUM OF 48 X BAR DIAMETER AND EMBED STANDARD 90 DEGREE HOOKS A MINIMUM OF 6-INCHES. LAP SPLICES SHALL BE STAGGERED SUCH THAT A MAXIMUM OF 50% OF THE TOTAL REINFORCEMENT IS SPLACED AT ANY ONE LOCATION. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. FIELD BENDING OF GRADE 60 REINFORCEMENT SHALL NOT BE ALLOWED. 17. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST 3" AGAINST AND PERMANENTLY EXPOSED TO EARTH ALL OTHER SURFACES 11/2" 18. SLABS -ON -GRADE: UNLESS NOTED OTHERWISE SHALL BE 4" CONCRETE, REINFORCED WITH 6X6 W1.4XW1.4 WELDED WIRE FABRIC CENTERED IN SLAB. UNLESS OTHERWISE DIRECTED BY SOILS REPORT PROVIDE MINIMUM 10 MIL VAPOR BARRIER OVER 4" OF COMPACTED SAND OR GRAVEL. 19. CAST -IN -PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. WOOD 20. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS. JOISTS: HEM -FIR NO. 2 (2X, 3X, AND 4X MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 850 PSI BEAM AND STRINGERS: DOUGLAS FIR LARCH NO. 1 (6 X AND LARGER MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 1,350 PSI STUDS PLATES & MISCELLANEOUS LIGHT FRAMING DOUGLAS FIR LARCH OR HEM -FIR NO. 2, MINIMUM BASIC DESIGN STRESS Fb = 850PSI, Fc = 1,300 PSI 21. GLUED LAMINATED MEMBERS SHALL BE FABRICATED AND IDENTIFIED AS REQUIRED BY ASTM D3737 AND A.I.T.C. A190.1. EACH MEMBER SHALL BEAR AN A.I.T.C. IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN A.I.T.C. CERTIFICATE OF CONFORMANCE. IN ADDITION ALL GLULAMS SHALL CONFORM TO APA PERFORMANCE STANDARD PRG-305. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb = 2,400 PSI, Fv = 240 PSI, E = 1,800,000 PSI. ALL CANTILEVERED BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 PSI, Fv= 240 PSI, E = 1,800,000 PSI. UNLESS OTHERWISE NOTED CAMBER ALL GLULAM BEAMS TO 2,000 FOOT RADIUS. WHERE REQUIRED BEAMS AND COLUMNS SHALL BE PRESSURE TREATED AFTER MANUFACTURE IN ACCORDANCE WITH AMERICAN WOOD -PRESERVATIVES ASSOCIATION STANDARD U1. 22. PARALLEL STRAND LUMBER (PSL): EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, PRODUCT DESIGNATION OR TYPE, THE PRODUCTION DATE, SPECIES OR SPECIES GROUP DESIGNATION, AND THE QUALITY CONTROL AGENCY. MEMBERS SHALL BE GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. STRUCTURAL CAPACITIES SHALL BE ESTABLISHED IN ACCORDANCE WITH ASTM D5456 AND PRODUCT SHALL HAVE AN APPROVED I.C.C.-E.S. EVALUATION REPORT. MEMBERS SHALL BE TRANSPORTED AND STORED PER MANUFACTURERS RECOMMENDATIONS AND SHALL NOT BE EXPOSED TO PROLONGED MOISTURE. MINIMUM REQUIRED DESIGN PROPERTIES: Fb = 2900 PSI, E _ 2200,000 PSI, Fv = 290 PSI. DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE WEYERHAEUSER. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. WOOD CONTINUED 23. LAMINATED STRAND LUMBER (LSL): EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, PRODUCT DESIGNATION OR TYPE, THE PRODUCTION DATE, SPECIES OR SPECIES GROUP DESIGNATION, AND THE QUALITY CONTROL AGENCY. MEMBERS SHALL BE GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. STRUCTURAL CAPACITIES SHALL BE ESTABLISHED IN ACCORDANCE WITH ASTM D5456 AND PRODUCT SHALL HAVE AN APPROVED I.C.C.-E.S. EVALUATION REPORT. MEMBERS SHALL BE TRANSPORTED AND STORED PER MANUFACTURERS RECOMMENDATIONS AND SHALL NOT BE EXPOSED TO PROLONGED MOISTURE. MINIMUM REQUIRED DESIGN PROPERTIES: Fb = 2325 PSI, Fv = 310 PSI, E = 1,550,000 PSI, LSL RIM JOISTS SHALL CONFORM TO ANSI/APA PRR 410 AND SHALL BE MARKED IN ACCORDANCE WITH THE STANDARD. DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY WEYERHAEUSER. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER, ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. 24. PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOIST MANUFACTURED BY THE WEYERHAEUSER. ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH PLYWOOD WEB JOIST PROVIDED. 30. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1-09 OR PS 2-10 AND AMERICAN PLYWOOD ASSOCIATION PERFORMANCE STANDARD PRP-108. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX AND NAILING REQUIREMENTS. EACH PANEL SHALL BE IDENTIFIED FOR GRADE AND GLUE TYPE BY THE TRADEMARKS OF AN APPROVED TESTING AND GRADING AGENCY. 31. ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE, PROVIDE 2 LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC. AND CONCRETE OR MASONRY. PRESSURE TREATED LUMBER SHALL COMPLY WITH THE AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) STANDARD U1, COMMODITY SPECIFICATION A. ALL TREATED LUMBER SHALL BEAR THE QUALITY MARK OF AN ACCREDITED INSPECTION AGENCY. THE QUALITY MARK SHALL INCLUDE: A. IDENTIFICATION OF TREATING MANUFACTURER B. TYPE OF PRESERVATIVE USED C. MINIMUM PRESERVATIVE RETENTION (PCF) D. END USE FOR WHICH THE PRODUCT IS TREATED E. IDENTITY OF THE ACCREDITED INSPECTION AGENCY F. STANDARD TO WHICH THE PRODUCT IS TREATED 32. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-2019. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. SHIMS, WHERE REQUIRED, SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL LAG SCREWS SHALL BE INSTALLED IN PRE - DRILLED HOLES. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON AND MAXIMUM NUMBER OF NAILS AS SPECIFIED BY THE MANUFACTURER SHALL BE PROVIDED. UNLESS NOTED OTHERWISE ALL SAWN LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS AND ALL PREFABRICATED PLYWOOD WEB JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "IUS" SERIES JOIST HANGERS UNLESS NOTED OTHERWISE. ALL CONNECTIONS IN CONTACT WITH PRESERVATIVE -TREATED OR FIRE -RETARDANT -TREATED WOOD, SHALL BE OF HOT DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. HOT DIPPED GALVANIZED FASTENERS SHOULD CONFORM TO ASTM STANDARD 153, AND HOT DIPPED GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM STANDARD A653 (CLASS G-185). STAINLESS STEEL FASTENERS AND CONNECTORS SHOULD BE TYPE 304 OR 316. NOTE: ELECTROPLATED GALVANIZED FASTENERS AND CONNECTORS ARE NOT TO BE USED WITH PRESSURE TREATED WOOD. SIMPSON PRODUCT FINISHES CORRESPONDING TO THE ABOVE REQUIREMENTS ARE ZMAX (HOT DIPPED GALVANIZED) AND SST300 (STAINLESS STEEL). STAINLESS STEEL HARDWARE AND FASTENERS SHALL NOT BE COMBINED WITH UNTREATED OR GALVANIZED MATERIAL. 33. WOOD FASTENERS: A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6d 2" 0.113" 8d 2-1/2" 0.131" 10d 3" 0.148" 12d 3-1/4" 0.148" 16d 3-1/2" 0.162" DESIGN IS BASED ON COMMON STEEL WIRE NAILS MEETING THE REQUIREMENTS OF ASTM F1667. USE OF ALTERNATE FASTENERS MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO THE START OF CONSTRUCTION. B. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. WOOD CONTINUED 34. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE SEATTLE BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF THE SEATTLE BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE AS SPECIFIED ABOVE. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLATION OF BOLTS AND LAG SCREWS SHALL CONFORM TO SECTIONS 12.1.3 AND 12.1.4 OF THE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. NATURALLY DURABLE OR PRESSURE TREATED WOOD SHALL BE PROVIDED WHERE REQUIRED BY SECTION 2304.12 OF THE SEATTLE BUILDING CODE. B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X6 AT 16" O.C. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2 x 8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED AND SHALL BEAR FULLY ON A MINIMUM OF TWO STUDS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE SOLID BLOCKING BETWEEN STUDS AT MID -HEIGHT OF ALL STUD WALLS OVER 10' IN HEIGHT. STUDS MAY BE NOTCHED, CUT, OR PENETRATED WITH ROUND BORED HOLES AS FOLLOWS: STUD SIZE MAXIMUM NOTCH / CUT MAXIMUM BORED HOLE 2X4 7/8" 1-3/8" 2X6 1-3/8" 2-1/8" BORED HOLES SHALL NOT BE LOCATED WITH 5/8" FROM THE EDGE OF THE STUD OR AT THE SAME LOCATION AS A NOTCH OR CUT. WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d AT 12" O.C. AND LAP MINIMUM 4'4' AT JOINTS AND PROVIDE EIGHT 16d NAILS AT 4" O.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 12" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/81, DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0" O.C. UNLESS INDICATED OTHERWISE. PROVIDE 3"x3,, x1/4" HOT -DIPPED GALVANIZED PLATE WASHERS AT ALL ANCHOR BOLTS. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d NAILS @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5d COOLER NAILS FOR 1/2" GWB AND 6d COOLER NAILS FOR 5/8" GWB. PROVIDE 15/32" APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES), TOP AND BOTTOM PLATES WITH 8d NAILS @ 6" O.C. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH NAILS @ 121, O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. NOTCHES AT THE END OF JOISTS AND RAFTERS SHALL NOT EXCEED 1/4 THE DEPTH OF THE MEMBER. NOTCHES IN THE TOP OR BOTTOM SHALL NOT EXCEED 1/6 THE DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN THE MIDDLE 1/3 OF THE SPAN. THE DIAMETER OF ROUND HOLES BORED IN JOISTS AND RAFTERS SHALL NOT EXCEED 1/3 OF THE DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN 2" FROM THE TOP OR BOTTOM EDGE. TOENAIL JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH TWO ROWS OF 16d @ 12" O.C. ATTACH RAFTERS AND ROOF TRUSSES AT BEARING LINES WITH H2.5 @ 24" O.C. UNLESS OTHER METAL CONNECTIONS ARE PROVIDED. UNLESS OTHERWISE NOTED ON THE PLANS, APA RATED ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS AND NAILED WITH NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16d @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED. POST INSALLED ANCHORS 35. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REINFORCEMENT. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND ICC- ES REPORT. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER -OF -RECORD. SUBSTITUTIONS SHALL HAVE CURRENT ICC-ES APPROVAL. A. CONCRETE ANCHORS 1. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: a. SIMPSON STRONG -TIE "STRONG -BOLT" (ICC-ES ESR-1771) b. SIMPSON STRONG -TIE "TITEN-HD" (ICC-ES ESR-2713) 2. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. PRE - APPROVED ADHESIVE ANCHORS INCLUDE: a. SIMPSON STRONG -TIE "SET-XP" (ICC-ES ESR-2508) b. SIMPSON STRONG -TIE "AT-XP" (IAPMO UES ER-263) CUSTOM DESIGN ENGINEERING, INC Custom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q 0 LL Q LL, J z 0 j O LJJ �z z C- CQ G G J Q � LJJ O LU 0 LU 0 � Q z M CD LJJ CV C LO CD 0 o T' 0 Uj I-' C) _ 0 z N CD Q LJJ wzJ F_ Uj ;_ z o 5699 ,�� �tGIs SSIOIVAL LLI 1 /24/2024 PROJECT # Al-3356 SHEET N(kECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S100 BLD2024-0257 FOUNDATION PLAN NOTES: (TYPICAL UNLESS NOTED OTHERWISE) 1. SLAB ON GRADE ELEVATION VARIES PER ARCHITECTURAL PLAN. SLAB SHALL BE 4" THICK WITH 6x6 W1.4xW1.4 WWM CENTERED, U.O.N. PREPARE SOILS AND PROVIDE MINIMUM 6-MIL VISQUEEN VAPOR BARRIER UNDER ALL SLABS. SLABS SHALL BE SUPORTED ON MINIMUM 4 INCHES OF FREE DRAINING MATERIAL. 2. REFER ARCHITECTURAL SHEETS FOR DIMENSIONS AND ADDITIONAL TOP OF SLAB/CURB ELEVATIONS. FRAMING PLAN NOTES: (TYPICAL UNLESS NOTED OTHERWISE) FLOOR SHEATHING SHALL BE 23/32" TONGUE AND GROOVE APA RATED SHEATHING (SPAN RATING 40/20). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/1Od @ 6"ocAND 12"oc TO ALL INTERMEDIATE FRAMING. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING (SPAN RATING 24/0). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/ 8d @ 6"oc AND 12"oc TO ALL INTERMEDIATE FRAMING. ENTIRE ROOF HAS BEEN DESIGNED FOR ADDITIONAL 5 PSF SOLAR PANELS. SW- INDICATES STRUCTURAL WALL TYPE PER SCHEDULE 12/S6.0b. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. ALL HEADERS AND BEAMS ARE MARKED ON PLAN. REFER NOTE 5 FOR SUPPORT REQUIRMENTS. THE NUMBER OF COLUMN STUD PLIES ARE INDICATED GRAPHICALLY ON THE PLANS. TIMBER POST CALLOUTS ARE LISTED WHERE REQUIRED. A MINIMUM OF (2) STUDS ARE REQUIRED FOR ALL BEAMS & HEADERS. LEGEND F1 —1 F HANGER SW x INDICATES SHEARWALL PER SCHEDULE 12/S6.Ob ® COLUMNS BELOW INDICATES HOLDOWN. REFER _] COLUMNS ABOVE ,`p� DETAIL 8/S6.Ob FOR REQUIRED NUMBER OF STUDS, THREADED ABRUPT CHANGE IN SLAB/ ROD CALLOUT & EMBEDMENT INTO FRAMING ELEVATION CONCRETE. FB INDICATES FLUSH BEAM INDICATES SIMPSON STRAP � HOLDOWN. REFER DETAIL 8/S6.Ob 11, SPAN AND EXTENTS FTGX SPOTFOOTING - SIZE AND � REQUIRED REINFORCING PER FOOTING SCHEDULE CUSTOM DESIGN & ENGINEERING, INC Custom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q 0 LL Q 0 J C LU �z z C— CQ G G J Q CL LU 0 0 O Cn L 0 LU � a � LJJ C\I ¢ L0 U o U � T o CU 0 z Q r z 0 O CN CD I- z w �J H H O CD -CM CD � E Z 1 56997 t� 1 /24/2024 PROJECT # Al-3356 SHEET NQRECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FRAMING PLAN NOTES: (TYPICAL UNLESS NOTED OTHERWISE) 1. FLOOR SHEATHING SHALL BE 23/32" TONGUE AND GROOVE APA RATED SHEATHING (SPAN RATING 40/20). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/10d @ 6"oc AND 12"oc TO ALL INTERMEDIATE FRAMING. 2. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING (SPAN RATING 24/0). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/ 8d @ 6"oc AND 12"oc TO ALL INTERMEDIATE FRAMING. ENTIRE ROOF HAS BEEN DESIGNED FOR ADDITIONAL 5 PSF SOLAR PANELS. 3. SW- INDICATES STRUCTURAL WALL TYPE PER SCHEDULE 12/S6.0b. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. 4. ALL HEADERS AND BEAMS ARE MARKED ON PLAN. REFER NOTE 5 FOR SUPPORT REQUIRMENTS. 5. THE NUMBER OF COLUMN STUD PLIES ARE INDICATED GRAPHICALLY ON THE PLANS. TIMBER POST CALLOUTS ARE LISTED WHERE REQUIRED. A MINIMUM OF (2) STUDS ARE REQUIRED FOR ALL BEAMS & HEADERS. LEGEND n __1 F HANGER SW X INDICATES SHEARWALL PER SCHEDULE 12/S6.Ob ® COLUMNS BELOW INDICATES HOLDOWN. REFER COLUMNS ABOVE ,`p� DETAIL 8/S6.Ob FOR REQUIRED NUMBER OF STUDS, THREADED ABRUPT CHANGE IN SLAB/ ROD CALLOUT & EMBEDMENT INTO FRAMING ELEVATION CONCRETE. FB INDICATES FLUSH BEAM INDICATES SIMPSON STRAP Al HOLDOWN. REFER DETAIL 8/S6.Ob SPAN AND EXTENTS FTGX SPOT FOOTING - SIZE AND REQUIRED REINFORCING PER FOOTING SCHEDULE TRUSS FRAMING PLAN NOTES: TRUSS DESIGN LOADS: SNOW: 25 PSF, FLOOR LIVE: 40 PSF ROOF DEAD: 15 PSF, FLOOR DEAD: 15 PSF UPLIFT =10 PSF MINIMUM LWR CHORD DESIGN LOAD = 20 PSF (TYPICAL UNLESS NOTED OTHERWISE) PRE -MANUFACTURED TRUSSES PER SECTION IBC 2303.4.1 TRUSS DESIGN DRAWINGS. TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A WASHINGTON STATE LICENSED ENGINEER AND SHALL BE PROVIDED TO THE BUILDING OFFICIAL AND APPROVED PRIOR TO INSTALLATION. THESE CONSTRUCTION DOCUMENTS SHALL INCLUDE, AT A MINIMUM, THE INFORMATION SPECIFIED BELOW. TRUSS SHOP DRAWINGS SHALL BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO THE JOB SITE. 1. SLOPE OR DEPTH, SPAN AND SPACING; 2. LOCATION OF JOINTS; 3. REQUIRED BEARING WIDTHS; 4. DESIGN LOADS AS APPLICABLE; 5. TOP CHORD LIVE LOAD (INCLUDING SNOW LOADS); 6. TOP CHORD DEAD LOAD; 7. BOTTOM CHORD LIVE LOAD; 8. BOTTOM CHORD DEAD LOAD; 9. CONCENTRATED LOADS AND THEIR POINTS OF APPLICATION; 10. CONTROLLING WIND AND EARTHQUAKE LOADS; 11. ADJUSTMENTS TO LUMBER AND METAL CONNECTOR PLATE DESIGN VALUE FOR CONDITIONS OF USE; 12. EACH REACTION FORCE AND DIRECTION; 13. METAL CONNECTOR PLATE TYPE, SIZE, THICKNESS OR GAGE, AND THE DIMENSIONED LOCATION OF EACH METAL CONNECTOR PLATE EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE; 14. LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER; 15. CONNECTION REQUIREMENTS FOR: 15.1. TRUSS TO TRUSS GIRDER; 15.2. TRUSS PLY TO PLY; AND 15.3. FIELD SPECIES; 15.4. DRAG TRUSS CONNECTION TO SHEAR WALLS FOR THE LOADS SPECIFIED (WHERE APPLICABLE). 16. CALCULATED DEFLECTION RATIO OR MAXIMUM DEFLECTION FOR LIVE AND TOTAL LOAD; 17. MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS MEMBERS TO DESIGN THE SIZE, CONNECTIONS AND ANCHORAGE OF THE PERMANENT CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON THE TRUSS CONSTRUCTION DOCUMENTS OR ON SUPPLEMENTAL DOCUMENTS; AND 18. REQUIRED PERMANENT TRUSS MEMBER BRACING LOCATION. PROVIDE 4 X 6 DF 1 POST UNDER ALL GIRDER TRUSS SUPPORT LOCATIONS. THESE SUPPORTS MUST FOLLOW TO FOUNDATION TO DISTRIBUTE BEARING LOADS UNLESS NOTED OTHERWISE THE ROOF STRUCTURE SHALL CONSIST OF THE FOLLOWING: 1. LIGHT WEIGHT ROOF NOT EXCEEDING 6 PSF. THIS MAY CONSIST OF: LIGHT WEIGHT TILE, CEDAR SHAKES, COMPOSITION ROOF, LIGHT GAUGE METAL. 2. 15# FELT (OR AS SPECIFIED BY ARCHITECT). 3. 15 / 32 CDX OR 1/2" OSB. NAILED TO 2X NOMINAL FRAMING MEMBERS WITH 10D @ 6" O.C. EDGES & 12" O.C. FIELD. NO BLOCKING IS REQUIRED, UNLESS SPECIFIED ON PLAN. 4. INSULATION PER ARCHITECTURAL DRAWINGS. NO MODIFICATION IS ALLOWED ON PRE-ENGINEERED TRUSSES. FRAMING/BRACING IS ERECTORS RESPONSIBILITY. ROOF OVER FRAMING SHALL CONSIST OF THE FOLLOWING: 1. 2 X 4 HF #2 FOR SPANS UP TO 6' 2. 2 X 6 HF #2 FOR SPANS UP TO 8' 3. 2 X 8 HF #2 FOR SPANS UP TO 12' 4. 2 X 10 HF #2 FOR SPANS UP TO 16' REFER TO THE TYPICAL HEADER DETAIL ON THIS SHEET FOR HEADERS NOT SPECIFICALLY CALLED OUT ON THE PLAN. THIS DETAIL IS TYPICAL FOR NON -BEARING EXTERIOR WALLS. %J I 1 L.1 \ I L. V V I \/ L. V V V 1 \V V I 1 1 xf-%I V I I I V V 1 Lr'%I V SW-1 1 /419 = 1 I-0" ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE N SW-1 LE 0 0 0 0 0 0 0 0 0 0 0 0 000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 Em REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT U G . POO 0_1 CUSTOM DESIGN & ENGINEERING, INC Custom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q O L.L Q �J o o LU �z -Q z Q LU 0 _j = T' 0 0 Cn LU LU 0 a z Q N U w � 0 U w � T 0 CD CD z G Q L.L O c 0 CDCD C� J L L. cc LU w r)J rCD L CD o E z )�p 56997 t� O��S �OVAL�R�s��, 1 /24/2024 PROJECT # Al-3356 SHEET NQRECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S201 FRAMING PLAN NOTES: (TYPICAL UNLESS NOTED OTHERWISE) FLOOR SHEATHING SHALL BE 23/32" TONGUE AND GROOVE APA RATED SHEATHING (SPAN RATING 40/20). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/10d @ 6"oc AND 12"oc TO ALL INTERMEDIATE FRAMING. ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING (SPAN RATING 24/0). NAIL @ ALL FRAMED PANEL EDGES AND OVER SHEARWALLS w/ 8d @ 6"oc AND 12"oc TO ALL INTERMEDIATE FRAMING. ENTIRE ROOF HAS BEEN DESIGNED FOR ADDITIONAL 5 PSF SOLAR PANELS. 3. SW- INDICATES STRUCTURAL WALL TYPE PER SCHEDULE 12/S6.0b. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. �. ALL HEADERS AND BEAMS ARE MARKED ON PLAN. REFER NOTE 5 FOR SUPPORT REQUIRMENTS. i. THE NUMBER OF COLUMN STUD PLIES ARE INDICATED GRAPHICALLY ON THE PLANS. TIMBER POST CALLOUTS ARE LISTED WHERE REQUIRED. A MINIMUM OF (2) STUDS ARE REQUIRED FOR ALL BEAMS & HEADERS. LEGEND n -1 F HANGER SW X INDICATES SHEARWALL PER SCHEDULE 12/S6.Ob ® COLUMNS BELOW INDICATES HOLDOWN. REFER COLUMNS ABOVE ,`p� DETAIL 8/S6.Ob FOR REQUIRED NUMBER OF STUDS, THREADED ABRUPT CHANGE IN SLAB/ ROD CALLOUT & EMBEDMENT INTO FRAMING ELEVATION CONCRETE. FB INDICATES FLUSH BEAM INDICATES SIMPSON STRAP HOLDOWN. REFER DETAIL 8/S6.Ob SPAN AND EXTENTS FTGX SPOT FOOTING - SIZE AND REQUIRED REINFORCING PER FOOTING SCHEDULE TRUSS FRAMING PLAN NOTES: TRUSS DESIGN LOADS: SNOW: 25 PSF, FLOOR LIVE: 40 PSF ROOF DEAD: 15 PSF, FLOOR DEAD: 15 PSF UPLIFT =10 PSF MINIMUM LWR CHORD DESIGN LOAD = 20 PSF (TYPICAL UNLESS NOTED OTHERWISE) PRE -MANUFACTURED TRUSSES PER SECTION IBC 2303.4.1 TRUSS DESIGN DRAWINGS. TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A WASHINGTON STATE LICENSED ENGINEER AND SHALL BE PROVIDED TO THE BUILDING OFFICIAL AND APPROVED PRIOR TO INSTALLATION. THESE CONSTRUCTION DOCUMENTS SHALL INCLUDE, AT A MINIMUM, THE INFORMATION SPECIFIED BELOW. TRUSS SHOP DRAWINGS SHALL BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO THE JOB SITE. 1. SLOPE OR DEPTH, SPAN AND SPACING; 2. LOCATION OF JOINTS; 3. REQUIRED BEARING WIDTHS; 4. DESIGN LOADS AS APPLICABLE; 5. TOP CHORD LIVE LOAD (INCLUDING SNOW LOADS); 6. TOP CHORD DEAD LOAD; 7. BOTTOM CHORD LIVE LOAD; 8. BOTTOM CHORD DEAD LOAD; 9. CONCENTRATED LOADS AND THEIR POINTS OF APPLICATION; 10. CONTROLLING WIND AND EARTHQUAKE LOADS; 11. ADJUSTMENTS TO LUMBER AND METAL CONNECTOR PLATE DESIGN VALUE FOR CONDITIONS OF USE; 12. EACH REACTION FORCE AND DIRECTION; 13. METAL CONNECTOR PLATE TYPE, SIZE, THICKNESS OR GAGE, AND THE DIMENSIONED LOCATION OF EACH METAL CONNECTOR PLATE EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE; 14. LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER; 15. CONNECTION REQUIREMENTS FOR: 15.1. TRUSS TO TRUSS GIRDER; 15.2. TRUSS PLY TO PLY; AND 15.3. FIELD SPECIES; 15.4. DRAG TRUSS CONNECTION TO SHEAR WALLS FOR THE LOADS SPECIFIED (WHERE APPLICABLE). 16. CALCULATED DEFLECTION RATIO OR MAXIMUM DEFLECTION FOR LIVE AND TOTAL LOAD; 17. MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS MEMBERS TO DESIGN THE SIZE, CONNECTIONS AND ANCHORAGE OF THE PERMANENT CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON THE TRUSS CONSTRUCTION DOCUMENTS OR ON SUPPLEMENTAL DOCUMENTS; AND 18. REQUIRED PERMANENT TRUSS MEMBER BRACING LOCATION. PROVIDE 4 X 6 DF 1 POST UNDER ALL GIRDER TRUSS SUPPORT LOCATIONS. THESE SUPPORTS MUST FOLLOW TO FOUNDATION TO DISTRIBUTE BEARING LOADS UNLESS NOTED OTHERWISE THE ROOF STRUCTURE SHALL CONSIST OF THE FOLLOWING: 1. LIGHT WEIGHT ROOF NOT EXCEEDING 6 PSF. THIS MAY CONSIST OF: LIGHT WEIGHT TILE, CEDAR SHAKES, COMPOSITION ROOF, LIGHT GAUGE METAL. 2. 15# FELT (OR AS SPECIFIED BY ARCHITECT). 3. 15 / 32 CDX OR 1/2" OSB. NAILED TO 2X NOMINAL FRAMING MEMBERS WITH 10D @ 6" O.C. EDGES & 12" O.C. FIELD. NO BLOCKING IS REQUIRED, UNLESS SPECIFIED ON PLAN. 4. INSULATION PER ARCHITECTURAL DRAWINGS. NO MODIFICATION IS ALLOWED ON PRE-ENGINEERED TRUSSES. FRAMING/BRACING IS ERECTORS RESPONSIBILITY. ROOF OVER FRAMING SHALL CONSIST OF THE FOLLOWING: 1. 2 X 4 HF #2 FOR SPANS UP TO 6' 2. 2 X 6 HF #2 FOR SPANS UP TO 8' 3. 2 X 8 HF #2 FOR SPANS UP TO 12' 4. 2 X 10 HF #2 FOR SPANS UP TO 16' REFER TO THE TYPICAL HEADER DETAIL ON THIS SHEET FOR HEADERS NOT SPECIFICALLY CALLED OUT ON THE PLAN. THIS DETAIL IS TYPICAL FOR NON -BEARING EXTERIOR WALLS. UPPER ROOF FRAMING PLAN 1 /411 = 1 I-01I _OW ROOF BELOW M CUSTOM DESIGN & ENGINEERING, INC ustom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q 0 LL Q LL, C.') z 0 G J C C) Lu ` z � -Q z Q � L.L Lu 4-1 0 0 "' 0 fn fnV Q z M � LJJ CC U CD 0 C.')w o T' 0 z Q r CD z - o Q � L.L L.L w 0 J CD Q ;CD E o z SS10NAL 1 /24/2024 PROJECT # Al-3356 SHEET NQRECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S202 INC CL POST, PLINTH & FOOTING SW PER PLAN 0-Am POST PER PLAN (2) #4 CONT. SLAB ON GRADE z CUSTOM DESIGN &ENGINEERING, PER PLAN 10" SQR. PLINTH REINF. ABU SERIES w/ (4)#4 x LVERT. & �� POST BASE \\X\ 0 (3) #3 x 0 @ 2 oc z °a °oho°0oo00 o °°o REMAINDER @ 6" oc #4 @ 12" HORIZ. Custom #4 @ 18" VERT. PER PLAN FOOTING PER SCHEDULE (2) #4 CONT. PER PLAN LU 1 2 3 4 � WALL & FOOTING POST, PLINTH & FOOTING LU WALL PER PLAN POST PER PLAN ABU SERIES SLAB ON GRADE PLAN POST BASE o �°o o ohoCD °g�°moo o��° SLAB ON GRADE PER PLAN M (2) #4s CONT. PER PLAN #4 @ 18" o.c. (3) #4 EA WAY FTG SIZE PER PLAN 5 6 7 8 9 10 11 12 SeatLU CD CD E S300 t NOTE: NOTCHES SHALL NOT OCCUR IN MORE THAN (2) SUCCESSIVE STUDS A 2x4 STUDS (3x4 SIMILAR) ANY NOTCH OR HOLE THRU STUDS EXCEEDING ABOVE DETAIL SHALL GET E.O.R. APPROVAL FOR POSSIBLE REINFORCING REQUIREMENTS PRIOR TO DRILLING/NOTCHING 01 (3) #4 CONT. 30 1%" MAX 2x6 STUDS (3x6 SIMILAR) ALLOWABLE NOTCHES IN STUDS - N. T. S 1 WIDTH SEE PLAN FOR SLAB THICKNESS AND REINFORCING. (TYP.) PLASTIC VAPOR BARRIER AND COMPACTED GRANULAR FILL PER PLAN TYPICAL SLAB EDGE- N. T. S 9 NOTE: BORED HOLES SHALL NOT BE LOCATED @ THE SAME SECTION OF STUD AS A NOTCH. 1%" MAX 2%" MAX HOLE SINGLE STUD HOLE (NO REINF. REQUIRED) MIN MIN 2%" MAX 3%" MAX HOLE DOUBLE STUDS HOLE (NO MORE THAN TWO 5/8MIN SUCCESSIVE STUDS 5/e" MIN MAY BE BORED) 2x4 STUDS 2x6 STUDS (3x4 SIMILAR) (3x6 SIMILAR) NOTE: BORED HOLES SHALL NOT BE LOCATED @ THE SAME SECTION OF STUD AS A NOTCH. HOLES ALLOWED THROUGH STUDS - N. T. S 2 NOTES: HEADERS PER PLAN (2)10d TOENAILS 2. PROVIDE (1) 2x CRIPPLE STUDS MINIMUM EA SIDE OF STUD TYPICAL, U.O.N. (typ.) 3. SEE ARCHITECTURAL DRAWINGS FOR OPENING FLOOR JOISTS SIZES AND LOCATIONS PER PLAN 4. 2x SOLID BLOCKING REQUIRED AT CEILING (2)16d EA END OR LINE, ALL PANEL EDGES, AND @ 8'-0"oc MAX. (2)10d TOENAILS BLOCKING SEE NOTE 4 (4)16d MIN (typ.) (2) 8d TOENAILS (typ.) (1) 2x CRIPPLE TYP UNO-SEE NOTE 2 KING STUD TYPICAL WALL OPENING FRAMING ELEVATION - N. T. S on 10 STUDS P DIAPHRAGM BOUNDARY PLYWOOD PANEL NAILING TO DIAPHRAGM BOUNDARY 8d@6"OC NAILING TO INTERMEDIA' FRAMING ME 8d@12"OC JOISTS PER PLAN BEAM PER PLAN TOE NAIL TO SUPPORT w/(2)16d EA. SIDE DCAAA DED DI ANI )UPPORT IDE STUD WALL PER PLAN TYPICAL BEAM TO STUD DETAIL - N. T. S 3 PLYWOOD PANEL EDGE NOTE: BEARING AND SHEAR WALL INTERSECTIONS SHALL BE CONSIDERED DIAPHRAGM BOUNDARIES, TYP NAILING TO SUPPORTED PLYWOOD PANEL EDGES PER PLAN (8d @ 6" min.) TYPICAL UNBLOCKED SHEATHING - N. T. S 7 11 IAIED QTIEEEAIEDQ BEAM PER PLAN HANGER PER NOTES OR PLANS QLJEATUTAI(1 JOIST DIRECTION VARIES PER PLAN. PROVIDE (1) BAY BLK'G @ 48"oc w/(4)8d NAILS WHEN JOIST RUN PARALLEL TO BEAM JOIST PER PLAN TYPICAL FLUSH BEAM CONNECTION - N. T. S 4 (8)16d @ 4"oc STAGGERED AT EACH SIDE OF SPLICE TOP CHORD SPLICE BOTTOM CHORD SPLICE 6'-0" MIN. BETWEEN SPLICES SPLICE TO OCCUR AT CL OF VERT. STUD (TYP.) 16d @ 12"oc STAGGERED ELSEWHERE TOP PLATE SPLICE - N. T. S 8 12 w CUSTOM DESIGN & ENGINEERING, INC Custom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q 0 LL Q CD J C O LU �z z C— CQ G G J Q CL LU 0 0 O Cn LU 0 � a z < M � N U LU CD CDC) � U LUT o 0 Q LU 0 C C) o C� Q C3 w rJ H H CD -CM CD CD � E Z 1 56997 t� O��S Ois 1 /24/2024 PROJECT # Al-3356 SHEET NQRECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S6.Oa 1).. AArAAnrn 1A11 irnr NAILING 1T (2) ROWS Q RACRADED WHERE NAILING _S OUT (2) ROWS PWALL 'LAN 3x MEMBER WHERE NAILING TYPE ,2) CALLS OUT (2) ROWS 0 0 PLYWOOD PANEL EDGE NAILING PER SHEARWALL SCHEDULE TO MATCH BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE TYPICAL UPPER LEVEL SHEAR WALL (SW) PANEL (WHERE IT OCCURS) EDGE OF SW SHEATHING SHEAR WALL EDGE/BOUNDARY MEMBER PER HOLD-DOWN SCHEDULE HOLD-DOWN STRAP PER PLAN (IF APPLICABLE) z' GAP EDGE OF SW SHEATHING PANEL BLOCKING 2 X FOR SW-1 & SW-2 3XFOR SW 3& GREATER EDGE OF SW SHEATHING HOLD-DOWN TO FOUNDATION (REFER TO PLAN FOR SIZE & HOLD-DOWN SCHEDULE FOR BOLT) 2XPTHF2SILL FOR SW-1 & SW-2 3XPTHF2SILL FOR SW 3 & GREATER EDGE OF SW SHEATHING SHEARWALL PER PLAN 3x MEMBER WHERE NAILING TYPE ;2'CALLS OUT (2) ROWS T �v nnDnARGD INUCDC NAILING 1T (2) ROWS SHEARWALL PER PLAN INTERSECTING WALL - INTERSECTING WALL (SEE LEFT IF SHEARWALL) (SEE LEFT IF SHEARWALL) SHEARWALL INTERSECTION DETAILS - N. T. S 2 SHEAR WALL LENGTH EDGE OF SW SHEATHING AS DEFINED PER PLAN -------T PANEL BLOCKING 2 X FOR SW-1 & SW-2 3 X FOR SW 3 & GREATER FRAME NON -SHEAR WALLS PER SW-1 REQ'MNTS HOLD-DOWN STRAP PER PLAN LPT4 OR A35 CLIP SPACING PER SHEAR WALL (REQUIRED FOR SW-4 & GREATER. REFER TO DETAILS 4 & 5). ADD (2) 2 X STUDS OR SAME SIZE MEMBER AS ABOVE WHERE UPPER SW BOUNDARY MEMBER DOES NOT ALIGN WITH LOWER SW BOUNDARY MEMBER. NAILING OF THESE LOWERS MEMBERS SHALL MATCH THE BOUNDARY NAILING OF THE MEMBERS ABOVE. TOP PLATE MUST HEADER BE CONT.. OVER HEADER (UNO) / PANEL BLOCKING \ 2 X FOR SW-1 & SW-2 3 X FOR SW 3 & GREATER SHEAR WALL BOUNDRY MEMBER (HOLD-DOWN SCHEDULE) HOLD-DOWN TO FOUNDATION (REFER TO PLAN FOR SIZE & HOLD-DOWN SCHEDULE FOR BOLT) TEDGE OF SW SHEATHING . ......... ......... ......... ................... RIM JOIST (WHERE IT OCCURS) TYPICAL MAIN/LOWER LEVEL SHEAR WALL (SW) PANEL 2" 0 X 10 ANCHOR BOLT @ 48" O.C. IN NON -SHEAR WALLS SHEAR WALL LENGTH AS DEFINED PER PLAN TYP ANCHOR BOLT SIZE & SPACING PER SHEARWALL SCHEDULE NOTES FOR TYPICAL SEGMENTED SHEAR WALLS (SW) NO SCALE 1. REFER TO PLAN FOR SHEAR WALL LENGTH & HOLD-DOWN SIZES. 2. REFER TO SHEAR WALL SCHEDULE FOR SW PANEL SIZE, NAILING AND BLOCKING. 3. REFER TO SHEAR WALL SCHEDULE FOR BOUNDARY MEMBERS. 4. REFER TO HOLD-DOWN SCHEDULE FOR HOLD-DOWNS & BOLTS. TYPICAL SEGMENTED SHEAR WALLS - N. T. S 10 HOLD-DOWN PER PLAN J a z SHEAR WALL BOUNDARY MEMBER TIE ROD TO FOOTING VERT. REINF. (2) BARS REQ'D @ ANCHOR ROD ANCHOR ROD PER HOLD-DOWN SCHEDULE GRADE BEND BARS & EXTEND 40" BEYOND CONC. WALL & SILL PLATE SW PEI u CONFINEMENT R 3" E REINFORCEMENT 2 � (2) #4 STIRRUPS i u a 6 SILL PLATE c u FAILURE PLANE (ENGR. REF) TYPICAL FOOTING TYPICAL FOUND.HOOKED BAR INTO FOOTING REINF. PER (REFER TO FOUNDATION FOOTING DETAILS) DETAILS. THREADED ROD HOLD-DOWN REQUIREMENTS 1. THIS A TYPICIAL DETAIL IS APPLICABLE TO HOLD-DOWNS TD1-TD9. AND FOUNDATION WALLS AT LEAST 48" LONG. REFER TO SPECIFIC DETAILS FOR OTHER CONDITIONS. 2. THIS DETAIL IS APPLICABLE TO FOUNDATIONS WITH CRAWLSPACE. EXTEND THREADED ABOVE FLOOR RIM. HOLD-DOWN SCHEDULE - HOLD DOWNS ATTACHED BETWEEN FRAMED WALLS TYPE (2) CAPACITY (3)(4) COLUMN /BOLTS MST37 2010 2 2 X HEM -FIR 30 - 10d 0.148" DIA MST48 3105 2 2 X DOUG-FIR 38 - 10d 0.148" DIA MST60 4800 2 2 X DOUG-FIR 40 - 10d 0.148" DIA (2) MST48 6210 (2) 2 X DOUG-FIR (2) 38 - 1 Od (0.148" DIA)** (2) MST60 9600 (3) 2 X DOUG-FIR (2) 40 - 1 Od (0.148" DIA)** NOTES: (1) FILL ALL HOLES WITH 10d COMMONS NAILS (EXCEPTION SEE NOTE 3). (2) WHERE DOUBLE STRAPS ARE INDICATED SUCH AS (2) MST37 USE 10d X 1-1/21, COMMONS NAILS. SEE DETAIL A/S7.1 FOR DETAIL. (3) THE VALUES ABOVE ARE BASED ON A 161, CLEAR SPAN WITH HEM -FIR FRAMING & WIND LOAD DURATION. ** STAGGER NAILING PER DETAIL B M� SINGLE HDU DETAIL MIN. # OF STUDS SEE SINGLE HDU PER SCHEDULE DETAIL FOR CALLOUTSIN HDU PER PLAN COMMON SINGLE ANCHOR BOLT THROUGH BOTH HDU'S I Lu Lu STEM WALL & REINFORCMENT w PER PLAN 0- •II • 0 c 1• w FOOTING & REINFORCEMENT I• PER PLAN _ z co DOUBLE HDU DETAIL BOLTED -HOLD DOWN PER PLAN EDGE MEMBER (2) 2 X PLATES PER S.W. SCHEDULE -Ul 1 j ROD PER HOLD-DOWN RIM JOIST (TYP) SCHEDDULEj MST48 STRAP (2) 2 X STUDS HDR PER PLA STRAP LOC �: A EDGE MEMBER @ PER S.W. SCHEDULE (EACH -END) FOR STRAP INSTALLATION K2) 2 X STUDS UNDER HDR (TYP) TYPICAL HOLD-DOWN OVER HEADER BEAM FOR TD2 HOLD-DOWNS & GREATER HOLD-DOWN SCHEDULE - HOLD DOWNS ATTACHED TO CONCRETE MARK TYPE CAPACITY ANCHOR BOLT (MONO POUR) ANCHOR BOLT (TWO POUR) NUMBER OF STUDS / SOLID COLUMN NAILS / SCREWS /BOLTS TD1 STHD14 OR HDU4-SDS2.5 3285 SSTB24 FOR HDU4 SSTB24 FOR HDU4 2 2 X HEM -FIR 30 - 10d 0.148" DIA TD2 HDU5-SDS2.5 SPF/HF 4065 SSTB24 FOR HDU5 SSTB24 FOR HDU5 2 2 X DOUG-FIR 38 - 10d 0.148" DIA TD3 HDU5-SDS2.5 DF/SP) 5645 5" O x 24 ASTM A 7 5" O x 24 ASTM A 7 (2) 2 X DOUG-FIR 40 - 10d (0.148" DIA) TD4 HDU8-SDS2.5 7460 SSTB28 SSTB34 (2) 2 X DOUG-FIR 20 --" X 3 - SCREWS TD5 HDU 11-SDS2.5 9540 1" 0 X 24 ASTM A307 1" 0 X 24 ASTM A307 6 X 6 DF 2 POST 26 --" X 3 - SCREWS TD6 HDU 11-SDS2.5 11175 1" 0 X 24 ASTM A307 1" 0 X 24 ASTM A307 6 X 6 DF 1 POST TD7 HDU14-SDS2.5 1 14445 1" 0 X 24 ASTM A307 1" 0 X 24 ASTM A307 6 X 6 DF 1 POST TD8 HD12 15510 1-1/8" X 24 ASTM A307 1-1/8" X 24 ASTM A307 6 X 6 DF 1 POST TD9 I HD19 19070 1-1/4" X 24" ASTM 307 1-1/4" X 24" ASTM A307 6 X 6 DF 1 POST NOTES: 1. HOLDDOWNS SHALL BE MANUFACTURED BY THE SIMPSON STRONG -TIE CO, OR EQUIVALENT. 2. ALL BUILTUP STUDS SHALL RECEIVE SHEAR WALL EDGE NAILING. 3. INSTALL HOLD-DOWN BOLTS THRU THE THICKER SECTION OF THE SOLID POST. 4. 5/8" DIA ASTM A36 THREADED ROD EMBEDDED 12 INCHES IS ACCEPTABLE SUBSTITUTION FOR SST20, SST24, OR SST28. 3/4" DIA ASTM A36 THREADED ROD EMBEDDED 12 INCHES IS ACCEPTABLE SUBSTITUTION FOR SST28 OR SST34. HDU PER PLAN )LD-DOWN 1 M JOIST (TYP) 2 X PLATES HDR PER PLAN A STRAP OPTION FOR MST48 STRAP INSTL ONLY. HOLD-DOWN SCHEDULE - HOLD DOWNS ATTACHED TO EXISTING WITH EP XY MARK EPDXY EMBED COLUMN /BOLTS HDU2 7" 2 2 X HEM -FIR 30 - 10d 0.148" DIA HDU4 9" 2 2 X DOUG-FIR 38 - 10d 0.148" DIA HDU5 12" 2 2 X DOUG-FIR 40 - 10d 0.148" DIA HDU8 15" (2) 2 X DOUG-FIR Od (0.148" (2) 38 - 1 DIA)** HDU11 - (3) 2 X DOUG-FIR (2) 40 - 10d (0.148" DIA)** NOTES: 1. USE SIMPSON SERIES EPDXY AS INDICATED IN GENERAL NOTES TYPICAL HOLD-DOWN SCHEDULE - N.T.S 8 SHEAR WALL SCHEDULE MARK CAPACITY (LB/FT) (1) SHEATHING (PLYWOOD/OSB) (2) NAIL SIZE (3) EDGE NAIL SPACING (4) FIELD NAIL SPACING BOTTOM PLATE NAILING (2ND FLOOR) (6) SILL PLATE CONN. TO FOUNDATION (10) SHEAR CLIP SPACING (LTP4 OR A35 REFER TO DETAILS) TYP FRAMING (U.N.O FRAMING AT ABUTTING EDGES (11) FOUNDATION SILL PLATES PLATES SW-1 213 7/16 8d (0.131" DIA) 6 SEE NOTE 5 16d @ 6" O.C. 1" X 10 @ 35" O.C. LTP4 or A35 @ 16" O.C. 2 X 2 X 2 X (2) 2 X SW-2 254 7/16 8d (0.131" DIA) 4 SEE NOTE 5 16d @ 4" O.C. 1" X 10 @ 30" O.C. LTP4 or A35 @ 16" O.C. 2 X 2 X 2 X (2) 2 X SW-3 350 7/16 8d (0.131" DIA) 3 SEE NOTE 5 16d @ 4" O.C. 19" X 10 @ 20" O.C. LTP4 or A35 @ 16" O.C. 2 X 3 X 3 X (2) 2 X SW-4 492 15/32 1 Od (0.148 DIA) 3 SEE NOTE 5 16d @ 3" O.C. 5" X 10 @ 24" O.C. LTP4 or A35 @ 12" O.C. 2 X 3 X 3 X (2) 2 X SW-5 631 15/32 1 Od (0.148 DIA) 2 SEE NOTE 5 16d @ 2" O.C. 5" X 10 @ 18" O.C. LTP4 or A35 @ 9" O.C. 2 X 3 X 3 X (2) 2 X SW-6 836 15 BOTH SIDES 1 Od (0.148 DIA) 4 SEE NOTE 5 4" DIA LAG SCREW @ 4" O.C. 4" X 10 @ 18" O.C. SEE DETAIL 1 2 X 3 X 3 X (2) 2 X SW-7 1200 15 BOTH SIDES 1 Od (0.148 DIA) 3 SEE NOTE 5 'q" DIA LAG SCREW @ 3" O.C. 4' X 10 @ 14" O.C. SEE DETAIL 1 2 X 3 X 3 X (2) 2 X SW-8 1540 15 BOTH SIDES 1 Od (0.148 DIA) 2 SEE NOTE 5 4" DIA LAG SCREW @ 3" O.C. 4' X 10 @ 24" O.C. SEE DETAIL 1 2 X 3 X 3 X (2) 2 X NOTES 1 ALLOWABLE SHEAR CAPACITY ASSUMES HEM -FIR FRAMING, AND IS BASED ON THE 2018 IBC WITH INCREASES FOR LOAD DURATION. SW-7 & SW-8 REQUIRES DOUG-FIR FRAMING. 2 UPON ENGINEERS APPROVAL, 19/32" RATED SHEATHING MAY BE USED WITH NO CAPACITY REDUCTION. O.S. INDICATES ONE SIDE OR WALL TO BE SHEATHED, B.S. INDICATES SHEATHING ON BOTH SIDES. 3 8d NAILS = 0.131" dia 10d NAILS = 0.148" dia 4 FOR SHEAR WALL TYPES SW-3 AND HIGHER, ALL PANEL EDGE NAILING AND FOUNDATION SILL NAILING SHALL BE STAGGERED. 5 12" FIELD NAILING FOR STUDS 16" O.C. AND 6" FIELD NAILING FOR STUDS 24" O.C. 6 WHERE LAG SCREWS ARE REQUIRED, SCREW LENGTH MUST BE ADEQUATE TO ENSURE 2-1/41, PENETRATION OF THE LAG INTO THE RIM JOIST BELOW. PRE DRILL WITH 3/16" DIA LEAD HOLE. 7 ADDITIONAL BOTTOM PLATE ANCHORS ARE ONLY REQUIRED AT WALLS DESIGNATED ON PLANS AS PERFORATED SHEAR WALLS. THESE ANCHORS ARE NOT REQUIRED AT FOUNDATION SILL PLATES. 8 ALIGN STRAPS WITH WALL STUDS AND CENTER AT FLOOR SHEATHING. 9 WALLS WITH OUT SHEAR WALL ID SHALL CONFORM SW-1. 10 3" x 3" x 1/4" GALVANIZED PLATE WASHER IS REQUIRED. EMBED ANCHOR BOLTS 7.5" MINIMUM. REFER TO S-1 TO PRESSURE TREATING NOTES FOR ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED LUMBER. REFER TO FOUNDATION WALL SILL BOLTING REQUIREMENTS WHERE ANCHOR BOLT SPACING MAY LESS THAN SHOWN PER THIS TABLE. 11 REFER TO HOLD-DOWN TABLE WHERE SHEAR WALL EDGE MEMBERS ARE CONTROLED BY THE REQ'D HOLD-DOWN. AS A MINIMUM REQUIREMENT, A 3X MEMBER AT HOLD DOWNS SHALL BE USED. WHERE (3) 2 X MEMBERS ARE REQUIRED PER THE HOLD-DOWN TABLE, USE (1) 3 X & (1) 2 X. SHEAR WALL SCHEDULE - N. T. S 12 CUSTOM DESIGN & ENGINEERING, INC ustom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q O v- LL Q Lu J z O J O im O Lu �z Q z J LL Lu }+ Q 0 O Lu 0 a z < M � LJJ CV ¢ LO U Luw � 0 U � 1- 0 o_ VJ Q ° I- � 0 W M� uj 1 1 c 0 / CN CD w ^ L CD i o z 56997 19�1 O��S OIST 1 /24/2024 PROJECT # Al-3356 SHEET N(kECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S600b itorliffAV FULL DEPTH RIM SHEARWALL PER PLAN LSLI BOUNDARY NAILING PER SW SCHEDULE SHEARWALL PER PLAN TRUSS PER PLAN 1 24 8d @ 6" oc _\ BLK'G @32"oc I) 10d NAILS 5 6 7 8 IOU @6"o- 3x LEDGER w/ (2) R 5/8" DIAx7" LAGS Cc -ALIGN W/ STUDS ROOF FRAMING PER PLAN LRU SERIES HANGERS = SW PER PLAN / (WHERE OCCURS) FRAMING & SHEATHING ER PLAN SHEARWALL PER PLAN 2x4 CONT BLCK'G @ 8d @ 6" o.c TOP & 16d @ 6" o.c SIDE BLK'G @32"oc ATTACH w/ (4) 10d NAILS ROOF FRAMING PER PLAN BEAM PER PLAN 8d @ 6" oc BLK'G @32"oc ATTACH w/ (4) 10d NAILS TRUSS PER PLAN 9 10 11 12 POO CUSTOM DESIGN & ENGINEERING, INC Custom Design and Engineering, In 6021 Roosevelt Way Ne Seattle, WA 98115 www.cdengr.com email: kam@cdengr.com Q MM 0 LL Q 2EiJ o o o w �z -Q z Q CL w o 0 0 Cn cU O F_ M � LJJ N F— U w � 0 U w � 1— 0 CU 0 c 0 CN CD V J - Q w 1 ' ' ■ ■ ■ L CD QQ z I 56997 t� O��S ��VA�R�s��, 1 /24/2024 PROJECT # Al-3356 SHEET NQRECEIVE Mar 15 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT S601 INC Custom Design and Engineering, In 6021 Roosevelt Way Ne PARAPET -SHEATH PER SW-1 IN SCHED. PARAPET - SHEATH PER SW-1 IN SCHED. A35 CLIP @ 24" O.0 oc FRAMING & SHEATHING 8d 6" oc A35 CLIP @ 24" O.0 @ PER PLAN FRAMING & SHEATHING PER PLAN CUSTOM DESIGN &ENGINEERING, BLCK @ 32"O.0 - H1 CLIP @ Seatt ATTACH w/ (4) 10d EA JOIST NAILS SW PER PLAN H1 CLIP @ SW PER PLAN EA JOIST (WHERE OCCURS) 1 2 3 4 2Ei CD T -SHEATH PER PARAPET - SHEATH PER SW-1 IN SCHED. SW-1 IN SCHED. A35 CLIP @ 24" O.0 A35 CLIP @ 24" O.0 8d @ 6" oc 8d @ 6" oc LU BLK'G @32"oc ATTACH w/ (4) 10d NAILS FULL DEPTH FULL DEPTH RIM RIM7/\1 CD SHEARWALL CLIP PER SW SCHEDULE SHEARWALL - - H1 CLIP (OR PER PLAN PER PLAN EQUIVALENT) @ EA TRUSS CLIP PER SW SCHEDULE 5 6 7 8 8d @ 6" oc 8d @ 6" oc BLK'G @32"oc FULL DEPTH CONT STRAP PER 5699 FULL DEPTH ATTACH w/ (4) 10d NAILS RIM TRUSS PER PLAN PLAN BLK'G @32"oc RIM ATTACH w/ (4) 10d NAILS SHEARWALL CLIP PER SW SCHEDULE SHEARWALL H1 CLIP (OR \ PER PLAN PER PLAN EQUIVALENT) @ EA TRUSS DRAG TRUSS (REFER TO PLAN FOR DESIGN LOADING) 02 9 10 11 12 CCD D