APPROVED FIR BLD BLD2024-1307+Architectural_Plan+11.2.2024_2.24.50_PM+4598453GENERAL ENERGY CODE FOR ALTERATION
CHANGES TO EXISTING ENVELOPE? _NO_
CHANGES TO CONDITIONING OF THE SPACE? _NO_
CHANGES TO MECHANICAL SYSTEM? _NO_
CHANGES TO WATER -HEATING EQUIPMENT? _NO_
CHANGES TO MORE THAN 50% OF LIGHTING? _NO_
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
LEGEND
EXISTING CONDITION TO REMAIN
TO REMOVE
EGRESS PATH
Approved
Fire Marshal
Chris Burt
11 /16/2024
TFLOOR PLAN
SCALE 114" = 1 '-O"
----------------------------------------------
The following documentation shall be available on
site for the building inspector:
■
❑ COE APPROVED ARCHITECTURAL PLAN SET
❑ COE APPROVED STRUCTURAL PLAN SET
' ❑ COE REVIEWED CALCULATION PACKET
❑ ENERGY CREDIT WORKSHEET
■
❑ SITE PLAN
❑ CIVIL PLAN
■❑
:❑
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021
This project will require separate permits for Plumbing and
,Mechanical. Please apply for permits via MyBuildingPermit.Com
ZEMOVE
=XIST WINDOW
%ND FILL-IN WITH
FYP. EXT WALL
-ONSTRUCTION
SEE PLAN NOTES)
REMOVE
EXIST WINDOW
AND FILL-IN WITH
TYP. EXT WALL
CONSTRUCTION
(SEE PLAN NOTES)
PLAN NOTES
CONSTRUCTION TYPE VB
OCCUPANCY GROUP B
OCCUPANTLOAD „
1. TYP. EXTERIOR WALL CONSTRUCTION:
2X6 DF#2 STUD FRAME @ 1 6" OC
R-19 INSULATION
4' X 8' X 1 /2" OSB SHEATHING VERT 6D NAILS @ 6" OC EDGES 1 2" OC
2. THERE IS NO LIGHTING SCOPE INCLUDED IN THIS PROJECT
:ity Of Edmonds
Building Department
Work TI, CHANGE OF USE
...................................... ............................................
Address, 8311 212TH ST SW
�..............................................................
Owner VTL HAIR SALON
................................
Approved Date
Building Official
..........
11/14/2024
........... . .. ...
................................... : ........ I'll, ......... I'll, ......... I'll ..........
Eris. Carter
....................................................
Permit Number:
.........................................
BLD2024-1307
WINDOW SCHEDULE
MK
STAT
WINDOW
ROUGH OPENING
QTY
REMARK
STYLE
FRAME
GLAZING
W
H
SF
A
EXIST
SLIDING
VINYL
INSUL
6'0
5'0
30
2
1 TO REMOVE
B
EXIST
SLIDING
VINYL
INSUL
4'0
4'0
16
2
1 TO REMOVE
C
EXIST
SLIDING
VINYL
INSUL
5'0
4'0
20
6
D
EXIST
FIXED
VINYL
INSUL
110
6'0
6
1
E
EXIST
FIXED
VINYL
INSUL
5'0
67
33
1
TOTAL
12
DOOR SCHEDULE
MK
STAT
LOCATION
W
H
THICK
MAT'L
FIRE
RATING
REMARKS
1
EXIST
FRONT ENTRY
6'0
6'8
2"
WD
2
EXIST
REAR ENTRY
3'0
6'8
2"
WD
3
EXIST
OFFICE 2
2'6
6'8
1-3/4"
WD
4
EXIST
OFFICE 3
2'6
6'8
1-3/4"
WD
5
EXIST
SALON REAR DOOR
2'6
6'8
1-3/4"
WD
6
EXIST
RESTROOM (STD/UNI)
2'6
6'8
1-3/4"
WD
7
EXIST
RESTROOM (ADA/UNI)
3'0
6'8
1-3/4"
WD
8
EXIST
TO STORAGE BASEMENT
2'4
6'8
1-3/4"
WD
1 HR
9
EXIST
SALON
2'6
6'8
1-3/4"
WD
TO REMOVE
10
EXIST
SALON
2'6
6'8
1-3/4"
WD
TO REMOVE
OCCUPANT LOAD CALCULATION
(WAC 51-50-1004 TABLE 1004.5)
AREA NAME
AREA SF
FACTOR
OCCUPANT
LOBBY
282
15
19
KITCHEN
56
15
4
OFFICE 1
348
150
3
OFFICE 2
167
150
2
OFFICE 3
167
150
2
BEAUTY SALON
471
150
4
STORAGE BASEMENT
269
300
1
TOTAL
1,760
35
RECEIVED
Nov 05 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
a
LU
z
O
V)
w
H
z
w
Y
m
zo
orw
I I I
N N
M
� 0 0 I I I
I I I
N M V- LO
N
O
00
• a
Z
O z
J O
Q
� w
V)
Q V)
J N
N
Q
M
00
z
J
ry
O
O
J
LL
A
1