Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-1477+WA_State_Energy_Compliance_Form+11.8.2024_4.04.37_PM+4610814
11/7/24, 8:47 PM waenergycodes.com/print_ project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3ilNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdjlsdGdfc2Nvc... LIGHTING COMPLIANCE SUMMA 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project Title Edmonds Medical Pavilion - Suite 10 TI - 2021 WSEC For Building Department Use: Date: Nov 08, 2024 RECEIVED 7320 216th Street Project & Applicant Information Project Address Suite 10 Edmonds, WA 98026 11 /8/24 BLD2O24-1477 CI Y OF ND$ EDME Applicant PP Nowell Applicant Phone 206-667-0566 LNT SERVICES DE DEPARTMENT Applicant Email nowell.ancheta@stantec.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 80,000 New Building or Project Cond. Floor Area 1,728 Floors Above Grade 3 General Project Types Alteration AdditionAddition Lihflng Scope g Interior Lighting Compliance Method General Prescriptive Lighting Scope Lighting Project Description This project builds out a new medical office space on the basement level. Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope & parking) Adjustment Verification and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Energy Efficiency (AEC) No lighting or electrical additional energy efficiency Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included measures included in project rojecTitle i Edmonds Medical Pavilion - Suite 10 TI - 2021 WSEC a e VV U0, Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type P YP Specific Space Type P P YP Gross Interior Area SF ( ) LPA acts/SF ) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status P Conference/meeting/multipurpose 248 0.97 241 Corridors General 394 0.41 162 Electrical/mechanical 104 0.43 45 Lobby Elevator 227 0.65 148 Lounge/breakroom General 163 0.59 96 Office Enclosed < 250 sf 850 0.74 629 Restroom General 70 0.63 44 Proposed Total LPD 1,354 Totals 1 1 1,364 1 1,354 ==14 COMPLIES Proposed Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Troffer L02 18 31 558 Troffer LO1 11 39 1 1 1 429 Recessed downlight L03 9 13 1 1 1 117 https://www.waenergycodes.com/print_ project_ summary_form. ph p?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9hbH RIcmFOaW9uX2dOXzUwJ n Rmdj 1 sdGdfc2NvcGVfbm... 1 /2 11/7/24, 8:47 PM waenergycodes.com/print_ project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdjlsdGdfc2Nvc... Special application L04 1 24 24 Suspended L07 2 44 88 Suspended L05 2 64 128 Other fixture type X01 2 5 10 Proposed Total LPD 1,354 Project Title Edmonds Medical Pavilion - Suite 10 TI - 2021 WSEC Date Nov 08, 2024 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer L02 E2.10 LED New Fixture Description: 2x2 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Troffer L01 I E2.10 LED New Fixture Description: 2x4 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Recessed downlight L03 E2.10 LED New Fixture Description: Downlight Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Special application L04 E2.10 LED New Fixture Description: Vanity Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Suspended L07 I E2.10 LED New Fixture Description: Suspended Linear Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Suspended L05 E2.10 LED New Fixture Description: Strip Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: General display/accent lighting, occupancy or time switch Other fixture type X01 E2.10 LED New Fixture Description: Exit Sign Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://www.waenergycodes.com/print_ project _summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9hbH RIcmFOaW9uX2dOXzUwJ n Rmdj 1 sdGdfc2NvcGVfbm... 2/2