Loading...
APPROVED BLD FIR BLD2024-1478+Architectural_Plan+11.8.2024_4.06.34_PM+46108381 2 3 4 5 6 7 8 9 10 11 .. M. 0 LL w 0 U m a a 0 co 0 N V N O N SHEET INDEX GENERAL G0.00 COVER SHEET G0.21 LIFE SAFETY PLANS ARCHITECTURAL A2.01 DEMOLITION & NEW FLOOR PLAN - LEVEL 1 A2.22 DEMOLITION & NEW REFLECTED CEILING PLAN - LEVEL 1 A2.41 FF&E & FINISH PLANS - LEVEL 1 A3.10 PARTITION AND DOORS A4.10 INTERIOR ELEVATIONS A4.11 ENLARGED PLANS & INTERIOR ELEVATIONS SWEDISH IIIIIIIIIIIIIIIIIIIIIIIIIIIIEDMONDS A5.10 DETAILS MECHANICAL M001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS M002 MECHANICAL SPECIFICATIONS M101 LEVEL 1 - HVAC DEMO & NEW PLANS M102 BASEMENT - PLUMBING DEMO & NEW PLANS MEDICAL PAVILION -SUITE 100 M103 LEVEL 1 - PLUMBING DEMO & NEW PLANS M501 DETAILS & CONTROLS M601 EQUIPMENT SCHEDULES ELECTRICAL E0.00 SYMBOLS AND ABBREVIATIONS E0.01 ELECTRICAL SPECIFICATIONS E0.02 OVERALL ELECTRICAL PLAN LEVEL 1 E1.00 SUITE 100 LIGHTING DEMOLITION PLAN LEVEL 1 E1.01 SUITE 100 ELECTRICAL DEMOLITION PLAN LEVEL 1 E2.00 SUITE 100 LIGHTING PLAN LEVEL 1 E3.00 SUITE 100 ELECTRICAL PLAN LEVEL 1 E4.00 ELECTRICAL RISER E5.00 TELECOM RISER E6.00 PANEL SCHEDULES TYPICAL SYMBOLS 00 7320 216TH STREET 1 00 A7.00 00 A101 ELEVATION TAG/REFERENCE SUITE 100 00 1 1 BUILDING SECTION TAG/REFERENCE A101 A101 EDMONDS, WA 98026 1 WALL SECTION TAG/REFERENCE A101 1 DETAIL SECTION TAG/REFERENCE A101 PERMIT/BID SET 1 ENLARGEMENT TAG/REFERENCE A101 1 REVISION INDICATOR (CLOUD) TEXT ABOVE _ NEXT BELOW ELEVATION DATUM - WORK POINT / START POINT PROJECT NOTES PROJECT TEAM VICINITY MAP PROJECT INFORMATION 1. THESE DRAWINGS AND THE ACCOMPANYING SPECIFICATIONS ARE THE PROPERTY OF TGB ARCHITECTS AND ARE NOT TO BE COPIED OR REUSED OWNER: OWNER CONTACT: T „-_. ,, r . , _ V '•' SCOPE OF WORK FOR ANY OTHER PROJECT. HEALTHCARE REALTY 3310 WEST END AVENUE, SUITE 700 RYAN YOUNGMAN (206)495-7226 „ �t k - - - j el _ i REMODEL OF EXISTING PHARMACY INTO A NEW SPECIALTY CLINIC INCLUDING RECEPTION, WAITING, EXAM ROOMS, AND OTHER UTILITY AND ADMINISTRATIVE AREAS. NO STRUCTURAL WORK. NO EXTERIOR WORK. 2. DRAWINGS HAVE BEEN PREPARED FROM DATA AND DRAWINGS PROVIDED BY THE OWNER TO THE ARCHITECT. THE ARCHITECT HAS VERIFIED NASHVILLE, TN 37203 RYOUNGMAN@HEALTHCAREREALTY.COM I. ' , AREA OF WORK: 2,490 SQ FT EXISTING CONDITIONS TO THE BEST OF THEIR ABILITY. THE ARCHITECT ISSUES NO WARRANTY, NEITHER EXPRESSED NOR IMPLIED, FOR THE ACCURACY OR COMPLETENESS OF THE INFORMATION INDICATED HEREIN. Q • r► 3. NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF EXISTING CONDITIONS THAT ARE CONTRARY TO THOSE REPRESENTED WITHIN THE DRAWINGS OR WHERE DIMENSIONS VARY GREATER THAN 2" THAN THOSE SHOWN IN DRAWINGS. TENANT: PROVIDENCE I SWEDISH 1124 COLUMBIA, SUITE 210 TENANT CONTACT: EILEEN GOTTENMOELLER (573) 690-4031 R �_ • t ,o = �•` #s f ' _W1 •� ./ - M c ' _ � - '�► ,� ^ � • '/ ' ' ' •' LEGAL DESCRIPTION Section 29 Township 27 Range 04 Quarter NW - BLDGS ONLY ON FDP: THE W 331.60FT OF TR 29 EXC TH PTN OF TR 29 LY WLY OF FDL - COM AT NW COR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESCTH SLY TAP 35.44FT FIR SW COR OF SD TR 29 AS MEAS ALG S BDY SD TR &TERM OF LN HEREIN DESC (PER CITY EDM BLA REC 4. CONTRACTOR TO COORDINATE REQUIREMENTS FOR INFECTION CONTROL DURING COURSE OF CONSTRUCTION WITH OWNER PRIOR TO COMMENCEMENT OF WORK. SEATTLE, WA 98104 EILEEN.GOTTENMOELLER@PROVIDENCE.ORG ►, ' . ,,,I.� / AF NO 199909155005); REFER TO 00580700002901 FOR LAND 4v . . / TAX PARCEL NUMBER 5. PROVIDE 24" SQUARE ACCESS PANELS OR OF SIZES REQUIRED WHERE PLUMBING AND HEATING VALVES, WATER SWITCHES, OXYGEN PRESSURE SWITCHES, VENTILATION SPUTTER DAMPERS, ETC. ARE SHOWN ON PLUMBING AND MECHANICAL DRAWINGS. SUCH ACCESS PANELS TO BE INSTALLED IN THE FOLLOWING:A) GWBBOARD CEILINGS) METAL STUD AND MASONRY PARTITIONS. ARCHITECT: PROJECT LEAD: JEANELLE OWENS �► -- ^.� ' - oo © r�� 2818850 PRINCIPAL IN CHARGE : GINA DAIS • e o = U o • _ 6. WALL ASSEMBLIES MUST BE MAINTAINED AT ALL RECESSED FIRE EXTINGUISHER CABINETS AND ALL RECESSED EQUIPMENT. 7. PROVIDE FIRE EXTINGUISHER CABINETS OF THE TYPE SPECIFIED. REFER TO FLOOR PLAN(S) FOR LOCATIONS. TGB ARCHITECTS 21911 76TH AVE W, SUITE 210 EDMONDS, WA 98026 425-778-1530 JOWENS@TGBARCHITECTS.COM �t" ' �nr� �^e• Y ti�•`� _'• « 1 ,,,�('jjM I AUTHORITY HAVING JURISDICTION AHJ ( 1 CITY OF EDMONDS %At•� APPLICABLE CODES 8. ALL SHAFT PARTITIONS EXTEND FROM FLOOR SLAB TO UNDERSIDE OF SLAB ABOVE. EXPOSED BEAMS WITHIN SHAFTS ARE TO BE FIREPROOFED MECHANICAL ENGINEER CONTACT: WITH 2-HOUR GWBBOARD ENCLOSURE. MECHANICAL ENGINEER: TAE KIM •i � BUILDING CODE: WA STATE BUILDING CODE (IBC WITH AMENDMENTS) - 2021 THE FIRE RATINGS OF ALL FIRE RATED PARTITIONS WILL BE STENCILED ABOVE CEILINGS, EACH SIDE OF PARTITIONS, BOTH SIDES OF CORRIDORS AND AS REQUIRED BY AUTHORITY HAVING JURISDICTION. STANTEC 3400 188TH STREET SW, SUITE 285 (206) 224-3602 TAE.KIM@STANTEC.COM - 7 f EXISTING BUILDING CODE: WA STATE EXISTING -BUILDING CODE NTT) WITH AMENDMENTS) 2021 (IEB9. ENERGY CODE: 2021 WA STATE ENERGY CODE (IECC WITH AMENDMENTS) 10. ALL GWB IS 5/8" TYPE'X' UNLESS NOTED OTHERWISE. LYNNWOOD, WA 98037 ►� �•.. •a «! i '`-� LIFE SAFETY CODE: NFPA 101 - 2012 FIRE CODE: INTERNATIONAL FIRE CODE (IFC) - 2021 MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE (IMC) - 2021 11. THE DRAWINGS AND THE SPECIFICATIONS ARE COMPLEMENTARY. WHATEVER IS INDICATED IN ONE IS ASSUMED TO BE INDICATED IN THE OTHER. NOTIFY THE ARCHITECT IN CASE OF DISCOVERED DISCREPANCIES. ELECTRICAL ENGINEER: ELECTRICAL ENGINEER CONTACT: NOWELL ANCHETA / t - %� • . �, • _ ! i PLUMBING CODE: UNIFORM PLUMBING CODE (UPC) - 2021 ELECTRICAL CODE: NATIONAL ELECTRICAL CODE (NEC) - 20201 ACCESSIBILITY CODE: ANSI A117.1 - 2017 (BY REFERENCE FROM IBC AND WSBC) STANTEC 12. ALL SUBSTRATES ARE TO BE SMOOTH PRIOR TO INSTALLATION OF FINISHES. 3400 188TH STREET SW, SUITE 285 (206) 667-0555 NOWELL.ANCHETA@STANTEC.COM NORTH LYNNWOOD, WA 98037 PROJECT LOCATION DEFERRED SUBMITTALS 13. ALL WORK AND MATERIALS TO CONFORM TO FACILITY STANDARDS. (,Y�' 0 1. FIRE SUPPRESSIONS SYSTEM <1 N 2. FIRE ALARM --------------------- i Obtain a separate Mechanical i permit from the City of Edmonds. -------------------' Approved with Conditions Fire Marshal ALL WORK SUBJECT OBTAIN ELECTRICAL TO FIELD PERMIT FROM Chris Burt INSPECTION FOR STATE LABOR & CODE COMPLIANCE INDUSTRIES 11 /26/2024 ;-.-..-.-..-.-..-.-..-.-..-.-..-......- KEYPLAN APPROVED OBTAIN A SEPARATE 11-26-2024 PLANS MUST BE PLUMBING PERMIT ON JOB SITE FROM THE CITY OF PLAN REVIEW EDMONDS. NOTES- APPROVED WITH '"'-"-'-"-'-"-'-"-'-"-'-"-'-"-'-" L-F CONDITIONS: City Of Edmonds 1. A SEPARATE FIRE ALARM PERMIT MAY BE REQUIRED SUBSEQUENT BuildingDepartment p TO CHANGES IN INTERIOR WALL LAYOUT. AREA OF WORK Work T.I. 2. A SEPARATE FIRE SPRINKLER PERMIT MAY BE REQUIRED SUBSEQUENT TO CHANGES IN Address 7320 216TH ST SW #100 INTERIOR WALL LAYOUT. Owner SWEDISH 3. CONFIRM EXIT PATH LIGHTING IS - ---PAVILL- -ION ----------IO - SUFFICIENT. DFM BURT Approved Date 12/31/2024 Building Official D ofisz1c Permit Number BLD2024-1478 tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 31626 REGISTERED ITECT L KENT GRE STATE OF WASMWTON SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT COVER SHEET ISSUANCE No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: JLO DRAWN BY: GMD SHEET NO GOmOO 1 PA 3 4 5 6 7 8 J 10 11 �e x 0 M G c.� In a a 0 co 0 (V CV 0 W 1 \ LIFE SAFETY PLAN - LEVEL 1 1 % 1'. = 10'-0" 2 3 Tr)l 1('W r)(11A/KI 4 5 6 7 8 9 10 11 LIFE SAFETY PLAN NOTES 1. THE LIFE SAFETY PLANS HAVE BEEN DEVELOPED FROM EXISTING STATEMENT OF CONDITION DRAWINGS PROVIDED BY THE OWNER. ANY CONDITION THAT NEEDS TO BE UPGRADED TO MEET LIFE SAFETY CODE, BUILDING CODE, AND AHJ REQUIREMENTS AND NOT NOTED IN THESE DRAWINGS IS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER. 2.. VERIFY THAT WITHIN THE SCOPE OF WORK AREA: A. ALL EXISTING PARTITIONS, LABELED IN THESE DOCUMENTS AS FIRE RATED OR AS A SMOKE BARRIER OR SMOKE PARTITION MEET THE REQUIREMENTS OF THE PARTITION TYPE. B. ALL EXISTING DOORS AND OPENINGS IN EXISTING PARTITIONS MEET THE REQUIREMENTS OF THE PARTITION IN WHICH THEY OCCUR. 3. MODIFY EXISTING PARTITIONS SHOWN WITH NEW OR UPGRADED FIRE OR SMOKE RATINGS TO MEET THE NEW RATING. THIS PROCESS INCLUDES ANY REQUIRED PROTECTION OF OPENINGS IN THE PARTITION. 4. INSTALL DOORS IN CORRIDOR PARTITIONS TO RESIST THE PASSAGE OF SMOKE UNLESS NOTED OTHERWISE. 5. REFER TO ELECTRICAL DRAWINGS FOR LOCATION AND QUANTITY OF SMOKE DETECTORS. CODE ANALYSIS - BUSINESS OCCUPANCY - TENANT IMPROVEMENT 2021 WA STATE BUILDING CODE (REF IBC-2021) EXISTING BUILDING INFORMATION EXISTING BUILDING -MAIN OCCUPANCY PER RECORD DWGS B-BUSINESS EXISTING BUILDING -CONSTRUCTION TYPE PER RECORD DWGS II -A EXISTING BUILDING NUMBER OF STORIES PER RECORD DWGS 3 STORIES, PLUS BASEMENT EXISTING BUILDING SPRINKLERED? PER RECORD DWGS YES, COMPLYING WITH WSBC SECTION 903.3.1 OCCUPANCY AND USE -------- -------- MAIN (PREDOMINANT) OCCUPANCY/OCCUPANCIES CHAPTER 3 -------- BUSINESS SPACES SECTION 304 GROUP B - BUSINESS (2,490 SF) WAITING AREAS, CONFERENCE ROOMS, LOUNGES, AND BREAK ROOMS LESS THAN 750 SF OR WITH AN OCCUPANT LOAD OF LESS THAN 50 SECTION 303.1.2 PART OF THE MAIN OCCUPANCY - GROUP B - BUSINESS (250SF) A ROOM OR SPACE USED FOR STORAGE PURPOSES THAT IS ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS PART OF THAT OCCUPANCY SECTION 311.1.1 PART OF THE MAIN OCCUPANCY - GROUP B - BUSINESS (215SF) FIRE -RATING FOR BUILDING ELEMENTS, FIRE AND SMOKE PROTECTION FEATURES CHAPTER 6 CHAPTER 7 SEE ALSO "MEANS OF EGRESS" SECTION BELOW PRIMARY STRUCTURAL FRAME TABLE 601 1 HOURS AT CONSTRUCTION TYPE II -A INTERIOR BEARING WALLS TABLE 601 1 HOURS AT CONSTRUCTION TYPE II -A INTERIOR NON -BEARING WALLS AND PARTITIONS TABLE 601 0 HOURS AT CONSTRUCTION TYPE II -A FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS TABLE 601 1 HOURS AT CONSTRUCTION TYPE II -A ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS TABLE 601 1 HOURS AT CONSTRUCTION TYPE II -A SHAFT ENCLOSURES SECTION 713.4 2-HR OR 1-HR DEPENDING ON NUMBER OF CONNECTED FLOORS, BUT NOT LESS THAN 2-HR WHEN FLOOR CONSTRUCTION IS 2 HR. ELEVATOR LOBBY ENCLOSURES SECTION 3006.2 NOT REQUIRED IN B-OCCUPANCY, WHERE SPRINKLERED, UNLESS CORRIDORS ARE REQUIREDTO BE FIRE -RESISTIVE RATED. STAIR ENCLOSURES SECTION 1023.2 2-HR OR 1-HR DEPENDING ON NUMBER OF CONNECTED FLOORS, BUT NOT LESS THAN 2-HR WHEN FLOOR CONSTRUCTION IS 2 HR. MEANS OF EGRESS CHAPTER 10 -------- OCCUPANT LOAD SECTION 1004 -------- CLINIC/BUSINESS AREAS TABLE 1004.5 2,025 SF / 1 OCCUPANT PER 100 SF GROSS = 21 OCCUPANTS ASSEMBLY -FUNCTION AREAS WITHOUT FIXED SEATING TABLE 1004.5 250 SF / 1 OCCUPANT PER 15 SF NET = 17 OCCUPANTS STORAGE TABLE 1004.5 215 SF / 1 OCCUPANT PER 300 SF GROSS = 2 OCCUPANTS PROJECT OCCUPANT LOAD SUM OF ABOVE TOTAL OCCUPANT LOAD = 40 OCCUPANTS NUMBER OF EXITS REQUIRED - MINIMUM SECTION 1006.2.1 TABLE 1006.3.2 2 (FOR OCCUPANT LOAD NO GREATER THAN 500) SEE ALSO "ONE EXIT ALLOWED" SECTION BELOW SPACES WHERE ONE EXIT IS ALLOWED SECTION 1006.3.3 TABLE 1006.2.1 TABLE 1006.3.3 2 IN SPRINKLERED GROUP B SPACES WITH NO MORE THAN 49 OCCUPANTS AND NO MORE THAN 100 FT COMMON PATH OF TRAVEL COMMON PATH OF TRAVEL (ALLOWABLE) TABLE 1006.2.1 100 FT IN GROUP B, WHEN SPRINKLERED ARRANGEMENT OF EXITS OR EXIT ACCESS DOORS SECTION 1007.1.1 PLACED AT A DISTANCE FROM ONE ANOTHER NOT LESS THAN ONE-THIRD THE DISTANCE OF THE MAXIMUM DIAGONAL OF THE SPACE SERVED IN A SPRINKLERED BUILDING EXIT ACCESS TRAVEL DISTANCE (ALLOWABLE) SECTION 1017 TABLE 1017.2 300 FT IN GROUP B, WHEN SPRINKLERED CORRIDOR CONSTRUCTION TABLE 1020.1 UNRATED IN OCCUPANCY GROUP B, WHEN SPRINKLERED CORRIDOR (ALLOWABLE) DEAD END LENGTH IN ROOMS OR SPACES REQUIRING MORE THAN 1 EXIT OR EXIT -ACCESS DOOR SECTION 1020.4 50 FT IN OCCUPANCY GROUP B, WHEN SPRINKLERED DOOR TYPES ALLOWED SECTION 1010.1.2 SWING TYPE DOORS. POWER -OPERATED DOORS. MANUALLY - OPERATED SLIDING DOORS SERVING AN OCCUPANT LOAD NOT EXCEEDING 10. DOOR SWING SECTION 1010.1.2.1 DOOR MUST SWING IN THE DIRECTION OF EGRESS TRAVEL WHEN SERVING A SPACE WITH AN OCCUPANT LOAD OF 50 OR MORE PANIC HARDWARE SECTION 1010.1.9.4 SECTION 1010.1.10 REQUIRED WHERE SERVING GROUP A OCCUPANCY WITH AN OCCUPANT LOAD OF 50 OR MORE. GROUP A HAVING AN OCCUPANT LOAD OF 300 OR LESS AND GROUP B MAY HAVE KEY OPERATED LOCKING DEVICES ON EGRESS SIDE OF MAIN DOOR(S) PROVIDED IT HAS READILY -DISTINGUISHABLE LOCKING HARDWARE AND RELATED SIGNAGE. PLUMBING FIXTURES REQUIRED CHAPTER 29 -------- WATER CLOSETS, URINALS TABLE 2902.1 IN B OCCUPANCY: 1 REQUIRED PER 25 OCCS TO 50, THEN 1 REQUIRED PER EACH ADDITIONAL 50 OR FRACTION THEREOF. URINALS MAY REPLACE WATER CLOSETS NO LESS THAN 25% OF THE MINIMUM SPECIFIED. THUS 1 REQUIRED. 1 PROVIDED. LAVATORIES TABLE 2902.1 IN B OCCUPANCY: 1 REQUIRED PER 40 OCCS TO 80, THEN 1 REQUIRED PER EACH ADDITIONAL 80 OR FRACTION THEREOF. THUS 1 REQUIRED. 1 PROVIDED. DRINKING FOUNTAINS TABLE 2902.1 SECTION 2902.5 IN B OCCUPANCY WITH OCCUPANT LOAD GREATER THAN 30: 1 REQUIRED PER 150 OCCUPANTS, THEN 1 PER EACH ADDITIONAL 500 OR FRACTION THEREOF. DRINKING FOUNTAIN MAY BE LOCATED OUTSIDE TENANT SPACE IF WITHIN ONE FLOOR AND 500 FT TRAVEL. THUS 1 REQD. 1 PROVIDED. LOCATION PER PLAN. SERVICE SINKS TABLE 2902.1 NO REQUIREMENT LIFE SAFETY PLAN SYMBOLS OUT OF SCOPE INCIDENTAL OCCUPANCIES (INDICATING USE, CLASSIFICATION, SQUARE FOOTAGE, AND OCCUPANTLOAD NON -RATED PARTITION SMOKE PARTITION 1-HOUR FIRE BARRIER 2-HOUR FIRE BARRIER ® ILLUMINATED EXIT SIGN (WITH DIRECTIONAL ARROW WHERE NECESSARY) FEC FIRE EXTINGUISHER CABINET (EXISTING) g0 DOOR FIRE RATING KEYPLAN ARE) EXIT ACCESS TRAVEL DISTANCE 25-0" OF COMMON PATH OF EGRESS tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com *3MMTEREDTECT STATE OF WASNNGTON SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT LIFES /\ IR�I RTMENT PLANS ISSUANCE No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: JLO DRAWN BY: GMD NORTH SHEET NO GOm2l 1 1 2 3 1 4 5 1 6 7 8 9 10 11 1 1 2 3 1 4 5 1 6 7 1 8 Y x 0 FLOOR PLAN - LEVEL 1 - DEMO 1 /8" = 1'-0" J 0 - ADD F-1 TO EXISTING DOOR AND O STOREFRONT U 3/o/ m al FLOOR PLAN - LEVEL 1 - NEW ~JJ 3/16" = l'-0" NORTH ® N wCi HALLWAY 119 SCHEDULER 125 ,LINDS TO REMAIN, JG CONSTRUCTION 9 10 11 DEMOLITION NOTES 1. DEMOLITION PLANS REPRESENT EXISTING CONDITIONS. THEY ARE INTENDED FOR REFERENCE ONLY. THESE PLANS ARE NOT INTENDED TO BE A DESCRIPTION OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED THROUGH DURATION OF WORK. 3. SEE CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 4. ALL OPENINGS IN SLABS, ROOFS, WALLS, CEILINGS, AND PARTITIONS CREATED BY PROJECT -RELATED DEMOLITION OR BY NEW CONSTRUCTION SHALL BE SEALED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 5. ALL OPENINGS IN EXTERIOR WALLS, EXTERIOR SOFFITS, AND ROOFS CREATED BY PROJECT -RELATED DEMOLITION OR NEW CONSTRUCTION SHALL BE CLOSED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, THERMAL INSULATION, WEATHER PROTECTION, WATER -PROOFING, VAPOR -RETARDATION, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW CLADDINGS AND FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 6. REPLACE OR REPAIR ALL FIREPROOFING REMOVED OR DAMAGED DURING DEMOLITION OR CONSTRUCTION, SO AS TO MAINTAIN THE FIRE -RATING OF EXISTING BUILDING ELEMENTS. 7. THE OWNER WILL REMOVE ALL EXISTING MEDICAL EQUIPMENT FROM THE AREA OF WORK PRIOR TO TURNING THE SPACE OVER TO THE CONTRACTOR. NOTIFY THE OWNER OF ANY MEDICAL EQUIPMENT REMAINING IN THE SPACE. 8. CONSULT WITH THE OWNER PRIOR TO DEMOLITION ABOUT MATERIALS INDICATED TO BE SALVAGED FOR THE OWNER'S USE, BUT NOT INTENDED FOR RE -USE ON THIS PROJECT. STORE ALL SUCH MATERIALS UNTIL THE OWNER CAN TAKE POSSESSION. 9. ANY MATERIALS AND EQUIPMENT INDICATED IN DRAWINGS TO BE SALVAGED AND REUSED ON THIS PROJECT TO BE STORED BY CONTRACTOR UNTIL SCHEDULED REINSTALLATION. CONSULT WITH OWNER IF LOCATION INTENDED FOR STORAGE IS IN SPACES BELONGING TO THE OWNER BUT NOT IN THE AREA OF WORK. 10. STABILIZE ANY EXISTING -TO -REMAIN BUILDING COMPONENTS THAT BECOME UNBRACED DUE TO SELECTIVE OR PARTIAL DEMOLITION. PROVIDE A SOUND PERMANENT STRUCTURE PER CODE. 11. PATCH AND REPAIR ALL EXISTING WALLS & FLOORS AFFECTED BY DEMOLITION TO MATCH ADJOINING FINISHES. DEMO PLAN SYMBOLS ROOM NAME ROOM NAME WITH NUMBER & AREA 101 DOOR TO BE DEMOLISHED c WALL TO BE DEMOLISHED DOOR TO REMAIN WALL TO REMAIN EXISTING DEMO — — TO REMAIN ztm 1-HOUR FIRE BARRIER jNOT IN SCOPE NORTH FLOOR PLAN NOTES 1. FLOOR PLANS MAY NOT INCLUDE TOTAL OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. SECURE NEW WALLS TO SUBSTRATE WITH FASTENERS LOCATED 2' FROM EACH END AND SPACED A MAXIMUM OF 16" O.C. 3. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR ANY CABINETS, EQUIPMENT, HANDRAILS, OR WHERE REQUIRED. 4. LOCATE ALL NEW DOORS 6" FROM HINGE SIDE OF ADJACENT WALL UNLESS NOTED OTHERWISE. 5. ALIGN NEW WALLS WITH ADJACENT EXISTING WHERE APPLICABLE FOR A SMOOTH, CONTINUOUS FINISH. 6. ADD COLUMN FURRING WITH 7/8" FURRING STRIPS & (1) LAYER OF 5/8" GWB EXTENDED TO 6" ABOVE CEILING AT ALL EXPOSED COLUMNS UNLESS NOTED OTHERWISE.. 7. ALL PARTITIONS SCHEDULED TO RECEIVE ACOUSTICAL INSULATION SHALL BE CONSIDERED ACOUSTICAL PARTITIONS AND SHALL BE CONSTRUCTED AND CAULKED AS SPECIFIED. FLOOR PLAN SYMBOLS ROOM NAME 901 ROOM NAME WITH NUMBER PARTITION TYPE TAG - SEE PARTITION 1i TYPE LEGEND EXISTING — NEW — NON -RATED PARTITION 1-HOUR FIRE BARRIER 101 DOOR TAG - SEE DOOR SCHEDULE 00 ELEVATION VIEW LOCATION REFERENCE 00 A7. 0 00 SHEET WHERE VIEW IS LOCATED jNOT IN SCOPE tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 3626 REGISTERED ITECT L eXT GRE STATE OF WASHWTON SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 DEMOL.ITilu"U'A DEVELOPMENT NEW F L�'0, E AE �=m kN - LEVEL 1 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: JLO DRAWN BY: JLO 00 0 co 0 (V V CV O N 1 1 2 3 1 4 5 1 6 7 8 10 11 SHEET NO A2mOl Y c� w U m a 1 2 3 4 5 6 7 1 8 IF o m FASTEN STRUT TO STRUCTURE ABOVE WITH APPROVED OR ENGINEERED FASTENERS BRACING WIRES FOUR #12 (MINIMUM)WIRES SPLAYED 90- DEGREES FROM EACH OTHER, AT AN ANGLE OF NOT EXCEEDING 45-DEGREES FROM THE PLANE OF THE CEILING COMPRESSION STRUTS FOR CEILINGS GREATER THAN 1000 SF, PROVIDE CISCA-COMPLIANT, CODE - COMPLIANT BRACING WITH COMPRESSION STRUUT. COMPRESSION STRUT MAY BE USG DONN- BRAND COMPRESSION STRUT OR ANY OTHER APPROVED OR ENGINNEERED SYSTEM, USING LIGHT -GAGE FRAMING, ELECTRICAL CONDUIT OR COLD -ROLLED STEEL SECTIONS. 90P SYd 4-§FgW MWITH ATP46VED OR ENGINEERED FASTENERS o o o p o 0 SEISMIC BRACING FOR CLGS GREATER THAN 1000 SF, AND CLGS UNATTACHED ON 2 OR MORE SIDES ALL CEILING -MOUNTED LIGHTING FIXTURES, AND CEILING -MOUNTED AIR TEMINALS AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. PENDANT -HUNG LIGHTING FIXTURES, LIGHTING FIXTURES WEIGHING 56 LBS OR MORE, AND AIR TERMINALS AND SERVICES WEIGHING 56 LBS OR MORE SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE. LIGHTING FIXTURES WEIGHING LESS THAN 56 LBS, AND AIR TERMINALS AND SERVICES WEIGHING 20 TO 56 LBS, SHALL HAVE TWO 12 GAGE HANGERS (SLACK WIRES ALLOWED) CONNECTING THE ITEM TO THE STRUCTURE ABOVE. CEILING -MOUNTED LIGHTING. AND CEILING -MOUNTED AIR TERMINALS AND SERVICES WALL OR PARTITION SUPPORTING PERIMETER OF SUSPENSIONS SYSTEM. C��O��NCcSgqT��HEREU�C�TION MAY VARY - FRAMED CONSTRUCTION WITH GYPSUM BOARD IS ATT/�CH AVY-DUTY CEILING GRID MEMBERS TO TWO ADJACENT WALLS, AND ALLOW 3/4" CLEARANCE TO CEILING GRID MEMBERS ON THEIR OPPOSITE WALLS. ACCOMPLISH BY MEANS OF 7/8" WALL MOLDINGS ALL AROUND WITH MFR'S SEISMIC CLIPS ALL AROUND. PROVIDE HANGERS WITHIN 8" OF PERIMETER WALLS, ALL SIDES I I I 0 0 0 0 - - --- - - -- -- -- --- - - -- - - - j ACOUSTICAL CEILING PANELS 2" MAXIMUM (MAY BE SQUARE -EDGE OR TEGULAR) F SUSPENSION SYSTEM (AND SEISMIC BRACING WHERE OCCURS) C3030.17 CONSTRUCTION OF ACP CEILINGS 3" = 1'-0" NOTE THE FOLLOWING: FURNISH HEAVY-DUTY CEILING GRID (SUSPENSION SYSTEM) IN ACCORDANCE WITH ASTM C-635. INSTALL CEILING GRID IN ACCORDANCE WITH ASTM C-636, INCLUDING PROVISIONS ON WIRE HANGERS, ATTACHMENT OF WIRE HANGERS, SPACING OF WIRE HANGERS, CARRYING CHANNELS, SPLICES, ASSEMBLY DEVICES, AND CEILING FIXTURES. INSTALL CEILING GRID IN ACCORDANCE WITH THE ADDITIONAL INFORMATION ON THIS DETAIL, WHICH IS A SUMMARY OF THE CISCA (ARCHITECTURAL) STANDARDS FOR SEISMIC ZONES 3 AND 4 (DESIGN CATEGORIES D, E, AND F). INSTALL CEILING -MOUNTED ITEMS AND FIXTURES, INCLUDING LIGHT FIXTURES, MECHANICAL SERVICES, CABLE TRAYS, CONDUIT AND SIMILAR IN ACCORDANCE WITH CISCA STANDARDS FOR SEISMIC ZONES 3-4. THIS MAY INCLUDE INDEPENDENT SUPPORT FOR SOME CEILING -MOUNTED ITEMS. PROVIDE CISCA-COMPLIANT SEISMIC BRACING AND COMPRESSION STRUTS ONLY IN CEILINGS OF 1000 SF OR GREATER ( SEE ASCE 7-13.5.6.2.2 SECTION C) IN CEILINGS WITHOUT LATERAL BRACING, PROVIDE FLEXIBLE CONNECTION FROM SPRINKLER BRANCH LINES TO SPRINKLER HEADS, IN LIEU OF OVERSIZED SPRINKLER OPENINGS IN CEILING IN CEILINGS GREATER THAN 2500 SF, PROVIDE 2" WIDE MINIMUM CEILING JOINT AS INDICATED AND DETAILED ON CEILING PLANS. O 0 +—+—+—+—AI—+—+—+—+ +—+—+— I I I I I I I I III I I I I I I I I I I I I I I I I I I I I I I —+—t = III +-1I—+—t, +II try =t—+—+—+— y—+—+—+— y —+—+ - I �E +- +-�I IF -+IT T -+-+-+ T -+-+ + T -+-+ -+�L II� I L IL I I I I I I I I I " —+—AI—+ ++—+—+—+—+—+—+—+—+—+—+—+—+—+—+—+—+1 +—�I I I I I I I I I III I I I I I I I I I I I I I I I I I I I I + — + — + — + — I —+—+—+—+II 1 + — + — + — y +—++ 1 + — + - +——+—+ _L_I_ �I—_ LJJS— I I I— I I I— I FI I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+ I I I IL I I I IL I I I IL I I I IL I I I IL I I I IL I I I +-+ +-+ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+— y+—+—+— y+—+—+— y+—++ 1+—+—+— 1+—+—+— 1+—+—+ I I I IL I I I IL I I I IL I I I IL I I I IL I I I IL I I I -+-+-+-T T+-+-+-T T+-+-+ +-+ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+—*r y—+—+—+—*r y —+— y—+—+—+— y —+— — ——+—+—+— — —+—+— h I I I IL I I I IL I IL I I I IL I I I IL I I I IL I I I +-+ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+— y+—+—+— 1+—+—+ 1+—++ 1+—+—+— 1+—+—+— 1+—+—+ I I I IL I I I IL I I I IL I I I IL I I I IL I I I IL I I I +-+-+-T T+-+-+-T T+-++� T+-+-+-� T+-+-+-� T+-+-+ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+— y—+—+—+ I I I IL I I I IL I I I IL I I I IL I I I IL I I I IL I I I +-+� T-+-++� T-+-+-+-� I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I —+—+—+— y =t + — + + — + — + + 1 =t + — + — + — 1 =t + — + — + — 1 =t + — + — + I I I I I I I I I I I I I I I I I I —+—+—+— T+—+ ELEVATOR +—+—++ T+—+—+— T+—+—+— ELEVATOR I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I CEILING PLAN - LEVEL 1 - DEMO 1 /8" = 1'-0" 9 10 11 DEMOLITION NOTES 1. DEMOLITION PLANS REPRESENT EXISTING CONDITIONS. THEY ARE INTENDED FOR REFERENCE ONLY. THESE PLANS ARE NOT INTENDED TO BE A DESCRIPTION OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED THROUGH DURATION OF WORK. 3. SEE CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 4. ALL OPENINGS IN SLABS, ROOFS, WALLS, CEILINGS, AND PARTITIONS CREATED BY PROJECT -RELATED DEMOLITION OR BY NEW CONSTRUCTION SHALL BE SEALED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 5. ALL OPENINGS IN EXTERIOR WALLS, EXTERIOR SOFFITS, AND ROOFS CREATED BY PROJECT -RELATED DEMOLITION OR NEW CONSTRUCTION SHALL BE CLOSED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, THERMAL INSULATION, WEATHER PROTECTION, WATER -PROOFING, VAPOR -RETARDATION, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW CLADDINGS AND FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 6. REPLACE OR REPAIR ALL FIREPROOFING REMOVED OR DAMAGED DURING DEMOLITION OR CONSTRUCTION, SO AS TO MAINTAIN THE FIRE RATING OF EXISTING BUILDING ELEMENTS. 7. THE OWNER WILL REMOVE ALL EXISTING MEDICAL EQUIPMENT FROM THE AREA OF WORK PRIOR TO TURNING THE SPACE OVER TO THE CONTRACTOR. NOTIFY THE OWNER OF ANY MEDICAL EQUIPMENT REMAINING IN THE SPACE. 8. CONSULT WITH THE OWNER PRIOR TO DEMOLITION ABOUT MATERIALS INDICATED TO BE SALVAGED FOR THE OWNER'S USE, BUT NOT INTENDED FOR RE -USE ON THIS PROJECT. STORE ALL SUCH MATERIALS UNTIL THE OWNER CAN TAKE POSSESSION. 9. ANY MATERIALS AND EQUIPMENT INDICATED IN DRAWINGS TO BE SALVAGED AND REUSED ON THIS PROJECT TO BE STORED BY CONTRACTOR UNTIL SCHEDULED REINSTALLATION. CONSULT WITH OWNER IF LOCATION INTENDED FOR STORAGE IS IN SPACES BELONGING TO THE OWNER BUT NOT IN THE AREA OF WORK. 10. STABILIZE ANY EXISTING -TO -REMAIN BUILDING COMPONENTS THAT BECOME UNBRACED DUE TO SELECTIVE OR PARTIAL DEMOLITION. PROVIDE A SOUND PERMANENT STRUCTURE PER CODE. 11. PATCH AND REPAIR ALL EXISTING WALLS & FLOORS AFFECTED BY DEMOLITION TO MATCH ADJOINING FINISHES. NORTH NORTH DEMO RCP SYMBOLS EXISTING DEMO — TO REMAIN Tt+ T T T7 I I I I r=_71 L — J ACOUSTICAL PANEL CEILING GWB CEILING 1-HOUR FIRE BARRIER DEMOLISHED LIGHT FIXTURE NOT IN SCOPE REFLECTED CEILING PLAN NOTES 1. REFER TO MEP PLANS IN CONJUNCTION WITH THIS SHEET. WHERE CONFLICTS AT LIGHT AND AIR DEVICE LOCATIONS EXIST BETWEEN MEP AND ARCHITECTURAL, REFER TO ARCHITECTURAL. 2. REFER TO LIFE SAFETY DRAWINGS OR MEP DRAWINGS FOR EXIT LIGHTS, SMOKE DETECTORS, AND DIFFUSERS. 3. FURNISH HEAVY-DUTY CEILING GRID (SUSPENSION SYSTEM) IN ACCORDANCE WITH ASTM C-635 AND INSTALL IN ACCORDANCE WITH ASTM C-580. 4. REPAIR AND REPLACE ANY CEILING GRID OR TILES DAMAGED DUE TO CONSTRUCTION TO MAINTAIN A NEW FINISHED LOOK. 5. NEW CEILING AND SOFFIT HEIGHTS ARE TO BOTTOM OF GRID OR BOTTOM OF FINISHED GWB AND ARE NOTED ON RCP. 6. CEILING GRIDS ARE DRAWN CENTERED IN THE ROOM AND SHALL BE INSTALLED CENTERED WITHIN THE ROOM AS SHOWN. 7. CEILING -MOUNTED LIGHTS, SPEAKERS, DIFFUSERS, GRILLES, AIR TERMINALS, SPRINKLER HEADS, AND SIMILAR ARE DRAWN CENTERED IN CEILING PANELS OR CENTERED IN ROOM. THESE DEVICES SHALL BE INSTALLED CENTERED WITHIN THE CEILING PANELS AND WITHIN THE ROOMS AS SHOWN. 8. REFER TO PLANS AND DETAILS FOR SOFFIT HEIGHTS, WIDTHS, DEPTHS, AND LOCATIONS. 9. ADD WOOD BLOCKING BETWEEN ROOF TRUSS @ MINIMUM 16" O.C. TO SUPPORT SOFFIT FRAMING. 10. NOT ALL REQUIRED ACCESS PANELS ARE SHOWN AND ARE TO BE PROVIDED AS REQUIRED. PAINT TO MATCH ADJACENT CEILING. 11. IN CEILINGS GREATER THAN 2500 SF, PROVIDE 2" WIDE MINIMUM CEILING JOINT AS INDICATED AND DETAILED ON CEILING PLANS. 12. PROVIDE CISCA-COMPLIANT SEISMIC BRACING AND COMPRESSION STRUTS ONLY IN CEILINGS OF 1000 SF OR GREATER ( SEE ASCE 7-13.5.6.2.2 SECTION C) 13. IN CEILINGS WITHOUT LATERAL BRACING, PROVIDE FLEXIBLE CONNECTION FROM SPRINKLER BRANCH LINES TO SPRINKLER HEADS, IN LIEU OF OVERSIZED SPRINKLER OPENINGS IN CEILING. TYPICAL CEILING SYMBOLS ID CEILING-MOUNTED OR OVERHEAD -MOUNTED LIGHTING BACKLIT MIRROR 0 RECESSED DOWN LIGHTING NURSE CALL DOME LIGHT - WALL MOUNTED 0 COVE/WALL WASH LINEAR FIXTURE Z Z ® ILLUMINATED EXIT SIGNS - GWB CEILING - PAINTED P-1 GWB CEILING - PAINTED P-2 ACCENT PAINT ALL SIDES ACP-1 - 24" X 48" CEILING PANEL tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com *V.ENT TERED TECT STATE OF WASHWTON SWEDISH -EDMONDS MEDICAL PAVILION - S U ITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED DEMOLIT,108V24 NEW REFLECTED DEVELOPMENT CEILINLEFISD�AwTv1E=T LEVEL 1 ISSUANCE No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: DRAWN BY: a 0 0 N N O N 1 PA 3 CEILING PLAN - LEVEL 1 - NEW 3/16" = V-0" 4 5 6 7 8 9 10 11 SHEET NO 2 3 1 4 I^ 5 6 7 8 4 FF&E NOTES Y c� w U m a a Lo 0 N v N O N C) C•� C) 3/o/ I I I I I 0001 I II CC06 OUCH DOWN TOUCH DOWN NCP EXAM ROOM #1 OFFICE #1 OFFICE #2 104 102 103 0004 II ® 1 / L l M / ----�---- - �- J 0004 WORKROOM 101A 0 ri RECEPTION 10 1 FF&E PLAN - LEVEL 1 - NEW r I % 3/16" = V-0" 0 0 00/o/ n i WAITING ROOM 100 L& FEC EXAM ROOM#2NM- NCP EXAM ROOM #3 EXAM ROOM #4 1 55 106 107 0004 0 1 0004 0004 77 I �1 MA/RN - 109 I I I L E1 ' A4.11 F_ 7 TYPICAL EXAM ROOM I CORRIDOR "A" 110 I■ II, lu I■ • I I • . I- .. iii/II o SOILED UTI 108 F -Mf1-r `7 L HALLWAY 119 I I LL� F7 L 3 LI FEC SCHEDULER SCHEDULER 124 125 n` L- 1 j Y C( j 11 -� `` �;-%% I'%//////�//////. ■' ////////// •�i♦��00®��♦� •�♦♦♦♦♦♦®O ♦` ® i -♦♦♦♦♦♦-♦�®® 110 ®� -�0® �® ►OO ,®♦��® I �♦♦♦♦ ■ '� ®r�► ILA --I_■_ �_ _�_� .■� �Milli i 1 1 I I AMARA AMAMI P. ■ ■��I ■ 1_��17 Ir��_■ �I/I/ 1 ' / ___- 1 i■■1��■■17 �� r�■_■iCd-ems■ _■ 11 �■ _�_■ ■L_--■■ 1-��_■I�a' ■i-■■_I■ -■■ ���■ ■11--_II t_��■IiiiT ■i��_hr�e ��I��-■ v • ILA -_I__ lJ_-_■ -■■■__-L_�-!■1S-[IR7Tw-■IL=17■ 1■_-_I■_ Yil_-S7[RT7-�Ff1E�1■■__ -_I_--1.■■ ■-__-_-RT-TT�1■_�17■ ✓/)--1R�4■T.IIL!Rr'1■.■111f�[.-.!2L__�■■_I I■■arL11k__`_�YIR ■-■____ �A1G17•l•II��C`I■N•1`I [Fl_I_I _I_�CILTA■�l�l`I■a■ _1� i .I _I--=IIF71-■iwill _S•ow MIN EN ILA--_ rrr�i-_■ 1 ■_--_ ----1.■ MEN 0 ILA-�-■I■IN �� �i i ■I-���a_■ it �v�■r- 1��-�_I■ ���■ii ■I-��>•-1.■ ii �� ��■ ff�mim mim am ol ------------------------------ ■�� _�-■ _��- II _-■�--���_- ■-__��-�__I--■_MAMMAS - ia2_1t■■te._l�m ■_■■■■■��_I■1 -1-_-_�_0 ln�I 1 -IY�_�__�IYIllinois ■ I■■�t mm �� ��- ; -�� MIY-��_`■Ili ��--� EN EN BMW ION �■■ram �0 �_■-7:IG11rliICA1■1WF13.'1_ ■1�3�1.[�■• .7 Ti1�t`fa�i �= ■ _�-iFI�Y_m� ■��-■ _��- � ■■11-�■ I--� Y-��-��IYIr� JW�_ ■��..-�ii..� nNo ��ommm Y-��aa--■ ON m IN m Iwo Y-�■�7� Y-_���_ Y�_�'� �� ■ I 1-!� rrrrrr■ism■■..di■_ ■ WE ■ f���� �■..i..r�■..i..r�■..rrr-rr 1� ■- ■ �■�1�1��1�1�� 1--� ■ TT7TrT7TrT7Tr ---� _-_ _-� _-- �� ■■-_ �� _ rrrr.i..i..i�r.i..i..i�1..i..rr 1■ rrrrrt�rt�rt■■■■u OWNER .���r ■ ����J �Ir■n..��- !.-_ �_ _��a�1■ _�ei�■ I��a�t■ _���J _■i �i_ ■��■moo®■■s>®■�.-,o�®s�_oaNT -- ---- -- - - - _��_■ _-�_ _lS�.�'IRTT\7fl}f�7■ _�1t1,n7TTwfiCr'�■ 1-rST'T►9T.f1r�t■ _�SIT'RTTT�R77 _-� ��I■ _-� _MJ:1 PI■.NJ�rJ PI [:7■�_■ ■���i1:1176N1'9Pl[al�J•■J __yJ:16'I6Nl�J PI [:N=■ -_yJ:1 Pl■�Nl•J PI [:Pl_■ _--_ _�-■ _��- ■_�7_■ ��7■■[1 ■-�r�r��i ��_■ 1��_ ■-�■ I--� I■ _-_�_ ■-■■m■N�-■■ _`_�_-■ ---■lefll_1 ■-ram■'■ ���■I�_■■■17 _�m_�■ --_�■Gfl■_■J -ir■■■7 �- _--_ ---- ---- ---- - --� --rill ----11 ----.■ 1--- _��i __�_��_ ii■■-��■I s 1■■ L2 In �■ n ■I■_■_f_■■■■_ � _�-■ ■ �� _��- ii�_�n� il■■-__■I�II�i ii m ■I- ■I�__■_`1■I _I■ ul ii ■li�l_�■`�11 ■I_�-■_■�■ I��_ ■-�■�!�-� i■ i_ __ i-I--■ MEN= I MIN MENNEN / ��. ♦ MAN= WE ill WEAL." NAME �AMAMI m_■ ■■ on ■■ ■■ ■■NIMA� ® - t ANN AM MR All M, /I/ �� I I I� ►ilk!.♦s�i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i ♦ ♦♦i♦ gr- '�I�� �I I I�■►♦i ■�L I/■ ♦ -- -MANOR � fir.%`��_�� ��%////.■�w®® � /l� I`iJ�� _� �`. �/ �iI'-0FA m1111N ��I in -..a� 111 I isMum ME AIIIAAAMEN �Y®o �/ � 9.1 ��/ p♦/ ■s1_ aii�� �i i1� ■ice_ _ %� FINISH PLAN - LEVEL 1 - NEW 3/16" = 1'-0" NORTH MATERIAL FINISH LEGEND NAME MANUFACTURER MATERIAL STYLE/SERIES COLOR/TEXTURE SIZE ACOUSTIC CEILING PANEL ACP-1 ARMSTRONG MINERAL FIBER ACOUSTICAL PANEL WHITE 24" X 48" BASE B-1 JOHNSONITE RUBBER BASE TBD 4" HIGH CARPET CPT-1 SHAW CONTRACT CARPET TILES TBD CONCRETE STAIN CONC-1 CORNER GUARD CG 1 CS GROUP CO-8 STAINLESS STEEL 1" LEG X FULL HEIGHT CUBICLE CURTAIN CC-1 TBD CUBICLE CURTAIN TBD FILM F-1 3M FASARA DUSTED CRYSTAL PER LOCATION PAINT P-1 SHERWIN WILLIAMS GENERAL WALL PAINT TBD P-2 SHERWIN WILLIAMS ACCENT WALL PAINT TBD P-3 SHERWIN WILLIAMS DOOR FRAMES TBD PLASTIC LAMINATE PL-1 TBD PLASTIC LAMINATE TBD PL-2 TBD PLASTIC LAMINATE TBD RESILIENT SHEET RS-1 TBD RESILIENT SHEET FLOORING TBD RESILIENT TILE RT-1 TBD RESILIENT PLANK TILE TBD SOLID SURFACING MATERIAL SSM 1 TBD SOLID SURFACING MATERIAL TBD TILE T-1 TBD CERAMIC WALL TILE TBD WALL PROTECTION WP-1 TBD RIDGID WALL PROTECTION TBD ROOM FINISH SCHEDULE FLOORING WALLS FINISH ROOM NAME ROOM NO. FINISH BASE NORTH EAST SOUTH WEST CEILING WAITING ROOM 100 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1/GWB RECEPTION 101 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1/GWB WORKROOM 101A CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 TOUCH DOWN OFFICE #1 102 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 TOUCH DOWN OFFICE #2 103 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 EXAM ROOM #1 104 RT-1 B-1 P-1/WP-1 P-1 P-1 P-1/WP-1 ACP-1 EXAM ROOM #2 105 1\1-1 B-1 P- IIV1/P-1 P- IIV1/P-1 P- I P- I ACP-1 EXAM ROOM #3 106 RT-1 B-1 P-1/WP-1 P-1 P-1 P-111VP-1 ACP-1 EXAM ROOM #4 107 RT-1 B-1 P-IMP-1 P-1/WP-1 P-1 P-1 ACP-1 SOILED UTILITY 108 RS-1 RS-1 P-1 P-1 P-1 P-1 ACP-1 MA/RN 109 RT-1 B-1 P-1 P-1 P-1 P-1 ACP-1/GWB CORRIDOR "A" 110 RT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 OFFICE III CPT-1 13-1 P-1 P-1 P-1 P-1 ACP-1 EXAM ROOM #5 112 RT-1 B-1 P-1 P-1 P-1/V1/P-1 P-1/V1/P-1 ACP-1 EXAM ROOM #6 113 RT-1 B-1 P-1 P-1 P-imp-1 P-1/WP-1 ACP-1 EXAM ROOM #7 114 RT-1 B-1 P-1 P-1 P-1IWP-1 P-1/WP-1 ACP-1 EXAM ROOM #11 115 RT-1 B-1 P-1/WP-1 P-1/WP-1 P-1 P-1 ACP-1 EXAM ROOM #10 116 RT-1 B-1 P-IMP-1 P-1/WP-1 P-1 P-1 ACP-1 EXAM ROOM #9 117 RT-1 B-1 P-1/WP-1 P-IMP-1 P-1 P-1 ACP-1 EXAM ROOM #8 118 RT-1 B-1 P-imp-1 P-1/WP-1 P-1 P-1 ACP-1 HALLWAY 119 RT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 CORRIDOR "B" 120 RT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 CLEAN UTILITY 121 RS-1 RS-1 P-1 P-1 P-1 P-1 ACP-1 TOILET #1 122 RS-1 RS-1 T-1 T-1 T-1 T-1 GWB TOILET #2 123 RS-1 RS-1 T-1 T-1 T-1 T-1 GWB SCHEDULER 124 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 SCHEDULER 125 CPT-1 B-1 P-1 P-1 P-1 P-1 ACP-1 CORRIDOR 130 RT-1 B-1 P-1 P-1 P-1 P-1 ACP-1/GWB 1. SEE FURNITURE AND EQUIPMENT SCHEDULES FOR CONTRACTOR RESPONSIBILITIES. 2. SEE INTERIOR ELEVATIONS AND ACCESSORY MOUNTING HEIGHTS FOR ADDITIONAL INFORMATION PRIOR TO INSTALL. 3. CONTRACTOR TO PROVIDE IN -WALL BLOCKING AS REQUIRED FOR EQUIPMENT. 4. CONTRACTOR TO VERIFY EQUIPMENT QUANTITIES SHOWN ON SCHEDULE WITH PLAN AND NOTIFY ARCHITECT/OWNER OF ANY DISCREPANCIES PRIOR TO PLACING EQUIPMENT ORDER. 5. ALL FURNITURE TO BE OWNER PROVIDED AND OWNER INSTALLED UNLESS OTHERWISE NOTED. FF&E SYMBOLS & ABBREVIATIONS THESE ABBREVIATIONS ARE FOR USE IN FF&E TAGS ONLY. SEE SPEC SECTION 1.02 FOR MORE INFORMATION ON FURNISH AND INSTALL RESPONSIBILITIES AND DEFINITIONS. OC FURNISHED BY OWNER / INSTALLED BY CONTRACTOR VC FURNISHED BY VENDOR / INSTALLED BY CONTRACTOR 00 FURNISHED / INSTALLED BY OWNER CC FURNISHED / INSTALLED BY CONTRACTOR VV FURNISHED / INSTALLED BY VENDOR 0001 FURNITURE & EQUIPMENT TAG NCL NURSE -CALL FF&E SCHEDULE FF&E NO. DESCRIPTION COORDINATION REQUIRED cD Z SE U m Lu w = U "' � co a � O > CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CC01 36 - GRAB BAR • CCO2 42 -GRAB BAR • CC03 18 - GRAB BAR (SEE ELEVATIONS FOR ORIENTATION) • CC04 TOILET PAPER DISPENSER CC05 TOILET SEAT DISPENSER CC06 PAPER TOWEL DISPENSER CC07 SIMPLIFIRE ALLUSION 40 - FIREPLACE INSERT • • CC08 COAT HOOKS (2) • CC09 SANITARY NAPKIN DSPOSAL • OWNER FURNISHED / CONTRACTOR INSTALLED 0004 WALL MOUNTED COMPUTER ARM • • OWNER FURNISHED / OWNER INSTALLED 0001 SOAP DISPENSER 0002 DESKTOP PRINTER • 0003 Midmark 626 Barrier -Free Power Examination Table • 0004 PRINTER • 0005 PHYICIANS TOOL 0006 SCALE • • 0007 METRO RACKS FINISH NOTES 1. ALL EXPOSED WALL SURFACES SHALL BE FINISHED. 2. FINISHES TO BE INDICATED ON FINISH PLAN, ROOM FINISH SCHEDULE, AND INTERIOR ELEVATIONS. REFER TO FINISH LEGEND FOR FINISH SELECTIONS. 3. FINISHES TO MEET FLAME SPREAD AND SMOKE DEVELOPED RATINGS PER CODE. 4. ALL MATERIALS TO BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTION/RECOMMENDATIONS AND INDUSTRY STANDARDS. 5. ALL FINISHES TO BE PATCHED AND REPAIRED SEAMLESSLY. ENSURE ALIGNMENT OF FINISHED SIDE WHERE TWO DIFFERENT WALL TYPES INTERSECT. NOTIFY ARCHITECT BEFORE PROCEEDING IF ALIGNMENT IS NOT POSSIBLE. 6. PATCH FINISHES AT CORRIDORS TO PROVIDE A SMOOTH TRANSITION BETWEEN NEW AND EXISTING. 7. ALL WALL / CEILING MOUNTED FIRE EXTINGUISHER CABINETS, ELECTRICAL PANELS, HVAC GRILLES, ACCESS PANELS, ETC. TO BE PAINTED TO MATCH ADJACENT WALL / CEILING COLOR. 8. PROVIDE COLOR MATCHED CAULK (MATCHING ADJACENT PLASTIC LAMINATE / SOLID SURFACE) AT CASEWORK. CONTRACTOR TO SUBMIT SAMPLES FOR APPROVAL TO ARCHITECT. 9. IF ANY ITEMS ARE IDENTIFIED REQUIRING FINISH/COLOR SELECTION NOT ADDRESSED IN THESE DRAWINGS, CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY & PROVIDE SAMPLES OF FINISH / COLOR OPTIONS FOR SELECTION, CLEARLY IDENTIFYING ANY ABOVE BASE BID. 10. ALL FLOORING TRANSITIONS TO COMPLY WITH ADA REQUIREMENTS. 11. FLOORING SHALL EXTEND UNDERNEATH ALL OPEN COUNTERTOP WORK SURFACES. 12. ALL FLOORING TRANSITIONS BETWEEN ROOMS TO BE CENTERED UNDER DOOR IN CLOSED POSITION U.O.N. TRANSITION STRIPS SHALL NOT BE VISIBLE FROM PUBLIC CORRIDOR SIDE. 13. CONTRACTOR TO BE RESPONSIBLE FOR TESTING SUBSTRATES FOR APPROPRIATE MOISTURE LEVELS PRIOR TO INSTALLING MATERIALS. 14. ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARDS. 15. FINISH ALL VERTICAL & HORIZONTAL SURFACES OF SOFFIT WITH SPECIFIED FINISH. FINISH SYMBOLS FINISH ABBREVIATIONS USED ON THIS AND OTHER FINISH SHEETS INCLUDE THE FOLLOWING: ACID ACOUSTICAL CEILING PANELS B BASE CC CUBICLE CURTAIN CG CORNER GUARD CONIC CONCRETE CPT CARPET FAB FABRIC GL GLAZING OR GLASS MTL METAL PT PAINT RS RESILIENT SHEET RT RESILIENT TILE SS STAINLESS STEEL SSM SOLID SURFACING MATERIAL T TILE PL/PLAM PLASTIC LAMINATE WC WALL COVERING WD WOOD WP WALL PROTECTION FLOOR PATTERN DIRECTION CPT-1 CORNER GUARD CPT-2 - - - - - WP-1 ---------- T-1 RS-1 NOT IN SCOPE T-1 tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com *Lt TERED TECT STATE OF WA"4TON SWEDISH -EDMONDS MEDICAL PAVILION SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT F F & E & IPIM Iv- V %%F ENT III PLANS - LEVEL 1 155UANUL No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: DRAWN BY: SHEET NO 1 2 3 4 5 6 7 8 7 1 2 3 4 5 6 7 8 9 10 11 WALL TYPE SCHEDULE DOOR SCHEDULE FIRE HEAD DOOR FIRE FRAME HARDWARE TYPE STUD SIZE THICKNESS RATING CONDITION INSULATION TYPE UL# NO. ROOM NAME WxH RATING TYPE MATERIAL FINISH GLAZING TYPE TYPE MATERIAL FINISH SET NO. COMMENTS A4 3-5/8" 47/8" NR FULL HEIGHT ACOUSTICAL BATT tgb architects Y 100 WAITING ROOM 3' - 0" x 7' - 0" 20 7 FG EXISTING EXISTING ADD F-1 TO EXISTING GLAZING EXISTING HM *P-3 7.1 *PUBLIC CORRIDOR SIDE TO MATCH ADJACENT FRAME FINISH /46 21/2 3 3/4 NR FULL HEIGHT ACOUSTICAL BATT 101A CORRIDOR 3'- 0" x T- 0" FG SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING GL-3 C ALUM CLR 5 1131 3-5/8" 4 7/8" NR 6" ABV CLG NONE ANNODIZED METAL DECK, WITH OR B4 3-5/8" 4 7/8" NR 6" ABV CLG ACOUSTICAL BATT 102 TOUCH DOWN OFFICE #1 3'- 0" x T- 0" FG SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING GL-3 C ALUM CLR 5 a .a a a • _ ; " ; a . a WITHOUT CONCRETE - DEPTH ANNODIZED tr _ AND CONFIGURATION MAY B6 21/2" 3 3/4' NR 6" ABV CLG ACOUSTICAL BATT _ t 425.778.1530 21911 76th Ave W. Ste 210 103 TOUCH DOWN OFFICE #2 3'- 0" x T- 0" FG SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING GL-3 C ALUM CLR 5 -- - , T-----`,-�" _ a_a : VARY. G2 2-112" 31/8" NR FULL HEIGHT NONE °� f 425.774.7803 Edmonds WA 98026 ANNODIZED 3-5/8" 41/4" NR FULL HEIGHT ACOUSTICAL BATT 104 EXAM ROOM #1 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 I I I G3 info@tgbarchitects.com 105 EXAM ROOM #2 3'_ 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 i i I i WHERE TRACK DOES NOT SUFFICIENTLY H1 3-5/8" 41/4" NR 6" ABV CLG NONE www.tgbarchitects.com 106 EXAM ROOM #3 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 I I I ALIGN WITH LOW FLUTE PROVIDE 3" X 16" 107 EXAM ROOM #4 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 i i i X 18 GAGE METAL STRAP ACROSS 2 LOW I I FLUTES, FOR PARTITION ATTACHMENT 108 SOILED UTILITY 3' - 0" x T - 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 1 I I I UNDERSIDE OF STRUCTURE ABOVE UNDERSIDE OF STRUCTURE ABOVE 110 CORRIDOR "A" 3'- 0" x T- 0" FG EXISTING EXISTING ADD F-1 TO EXISTING GLAZING EXISTING ALUM EXISTING 2.2 i i PROVIDE FASTENERS AT 24" OC 111 OFFICE 3'_ 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING GL-3 B HM P-3 3 i i ALONG TRACK INTO BOTTOM z 3-5/8" MTL TRACK 3-5/8" MTL TRACK 112 EXAM ROOM #5 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 i i \ FLUTES OR STEEL STRAPS. 113 EXAM ROOM #6 3'_ 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 i i I DEEP -LEG TRACK OR SLOTTED TRACK CEILING PER RCP 114 EXAM ROOM #7 T - 0" x T - 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 I ---- I ---- I ALLOWING 3/4" DEFLECTION, TYPICAL. 3625 115 EXAM ROOM #11 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 = CUT STUDS 3/4" SHORT. CEILING PER RCP 5/8" TYPE "X" GWB BOTH SIDES, EXTEND TO REGISTERED 116 EXAM ROOM #10 3' - 0" x 7' - 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 EXTEND GYPSUM BOARD TO STRUCTURE STRUCTURE ABOVE. ITECT 117 EXAM ROOM #9 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 IF INDICATED ON PARTITION TYPE ACOUSTICAL BATT INSULATION PER WALL TYPE 118 EXAM ROOM #8 3'_ 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 5 PROVIDE EDGE BLOCKING IF ACOUSTICAL BATT INSULATION PER WALL TYPE � KENT GRE 120 WAITING ROOM 3'- 0" x T- 0" FG SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING GL-1 A HM P-3 5 GYPSUM BOARD TERMINATES 5/8" TYPE "X" GWB (1) LAYER. EXTEND TO 3 5/8" MTL STUD STATE OF WASHNGTQN 121 CLEAN UTILITY 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 1 - LOWER THAN TOP TRACK STRUCTURE ABOVE. _ 3-5/8" MTL TRACK 122 TOILET #1 3' - 0" x T - 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 6 PARTITION (TYPE) PER FLOOR PLANS 123 TOILET #2 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 6 3-5/8" MTL STUD SEALANT & BACKER ROD BOTH SIDES 124 SCHEDULER 3' - 0" x T - 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 3 PARTITION ORIENTED PARTITION FINISH FLOOR AS SCHEDULED FINISH FLOOR AS SCHEDULED 125 SCHEDULER 3'- 0" x T- 0" FH SCWD WHITE BIRCH, PLAIN SLICE, STAIN TO MATCH EXISTING A HM P-3 3 PERPENDICULAR TO ORIENTED 150 CORRIDOR "A" 3'_ 0" x T- 0" 20 FH EXISTING EXISTING EXISTING HM *P-3 2.2 *PUBLIC CORRIDOR SIDE TO MATCH ADJACENT FRAME FINISH FLUTES PARALLEL TO - 41/4" 0' - 4 7/8" FLUTES DOOR HARDWARE SCHEDULE H6 UNRATED PTN-HEAD AT NO -FP COMPOSITE SLAB TYPE H1 - NR FURR_3-5/8"MTL_6" ABV CLG H10 TYPE A4 - NR_3-5/8"MTL_FULL HEIGHT O 1 1 /2" = l'-0" H 8 1 1 /2 = 1-0 O 1 1/2" - 1-0 = SET TYPE CR CLOSER PROTECTION DESCRIPTION DOOR, HARDWARE, AND WINDOW NOTES 1 CYPHER LOCKSET • WALL STOP, KICK PLATE MECHANICAL CYPHER LOCKSET 1. PRIOR TO FABRICATION, FIELD VERIFY ALL DIMENSIONS. UNDERSIDE OF STRUCTURE ABOVE 1.1 CYPHER LOCKSET • CONFIRM EXISTING WALL STOP AND KICK PLATE EXISTING DOOR, MECHANICAL CYPHER LOCKSET 2 CARD READER / ENTRANCE LOCKSET • • KICK PLATE, WALL STOP ELECTRIC STRIKE 2. REFER TO PROJECT MANUAL AND DOOR SCHEDULE FOR HARDWARE SETS. 2-1/2" MTL TRACK 2.2 CARD READER / ENTRANCE LOCKSET • • EXISTING DOOR, CONFIRM ELECTRIC STRIKE CEILING PER RCP 3 OFFICE LOCKSET WALL STOP 3. SMOKE RATED DOORS SHALL NOT BE UNDERCUT IN EXCESS OF THE CLEARANCE PERMITTED IN ACCORDANCE EXISTING FLOOR (ABOVE) CONSTRUCTION MAY VARY 4 STOREROOM LOCKSET WALL STOP WITH NFPA 80. 5 PASSAGE LATCHSET WALL STOP � � 4 5/8" TYPE "X" GWB BOTH SIDES, EXTEND TO 4. ALL DOOR TYPES ARE SHOWN AS SINGLE PANEL, WHETHER SINGLE OR DOUBLE. SEE PLANS FOR ACTUAL ' ___ STRUCTURE ABOVE. 6 PRIVACY LOCKSET MOP PLATE, WALL STOP OCCUPIED INDICATOR CONFIGURATION AND SWING OF DOORS. ® ® 1 7.1 ENTRANCE LOCKSET • EXISTING DOOR, MODIFY HARDWARE 20 GAGE MINIMUM METAL CLIP 1 5. ALL STILE SIZES, RAIL SIZES, LITE SIZES, AND LITE DETAILS SHALL BE PER STEEL DOOR INSTITUTE (SDI) ANGLE - SIZE AS NECESSARY FOR L--- ----------� STANDARDS, UNO. SECURE ATTACHMENT TO , ACOUSTICAL BATT INSULATION PER WALL TYPE STRUCTURE/DECKING ABOVE. i FASTEN CLIP ANGLE TO BRACE WITH FASTEN SIMILAR TO DETAIL FOR i (2) #10 SHEET -METAL SCREWS 2 1/2" MTL STUD GLAZING LEGEND 6. AT STOREFRONT DOORS, ALL STILE SIZES, RAIL SIZES, AND RAIL LOCATIONS SHALL BE PER THE _ MANUFACTURER'S STANDARD MEDIUM -STILE DOOR, UNO. PARTITION ATTACHMENT TO 2-1/2" MTL TRACK STRUM RE/DECKING ABOVE 20 GAGE MINIMUM, 2 1/2" MINIMUM STEEL STUD TAG DESCRIPTION COMMENTS 7. ALL GLAZING IN DOOR LITES AND SIDE LITES SHALL BE 1/4" TEMPERED GLASS AND SHALL BE WIRE -FREE FIRE .f i OR TRACK (BRACE) AT 4'-0" OC MAXIMUM - SEALANT & BACKER ROD BOTH SIDES < �� �Y ALTERNATE DIRECTION OF EACH BRACE WHERE GLASS WHERE DOOR IS REQUIRED TO BE FIRE -RATED. �� �� �� POSSIBLE — FINISH FLOOR AS SCHEDULED GL-1 CLEAR, SAFETY GLASS TEMPERED 3" X 3" X 3" X 20 GAGE MINIMUM, METAL GL 2 CLEAR, FIRE RATED GLASS APPROPRIATE TO RATING (PER SCHEDULE) OF OPENING 8. WHERE A DOOR IS LOCATED IN AN ACCOUSTICALLY RATED WALL, PROVIDE ACOUSTICAL INSULATION IN DOOR ��� ����%� CLIP -ANGLE - FASTEN TO BRACE AND TO 3 3/4" FRAME ON ALL SIDES. �� �� i -o RUNNER/TRACKWITH (2) # 10 SHEET -METAL GL-3 CLEAR WITH FILM, SAFETY GLASS TEMPERED GLASS WITH F-1 �� , i �G �° SCREWS -- OG1 TYPE A6 - NR_2-1/2"MTL_FULL HEIGHT PARTITION -TOP RUNNER/TRACK - SLOTTED OR 1 1/2" = V-0" NESTED OR DEEP -LEG AS NECESSARY TO DOOR TYPE LEGEND FRAME ACCOMODATE 3/4" DEFLECTION FRAME TYPE LEGEND UNDERSIDE OF STRUCTURE ABOVE Z I I CEILING TYPE AND EDGE CONDITION MAY 1 3-5/8" MTL TRACK VARY CEILING PER RCP STUDS CUT TO ACCOMODATE 3/4" FFRAMEDTPARTITION PER FLOOR OPNG SIZE GL OPNG SIZE PLANS - CONSTRUCTION MAY VARY PER OPNG PER OPNG 5/8" TYPE "X" GWB BOTH SIDES SCHEDULE SCHEDULE C1010.115 PARTITION TOP - BRACED 6" ABOVE CEILING SWEDISH -EDMONDS e _ ACOUSTICAL BATT INSULATION PER WALL TYPE 11/2"=1'0" MEDICAL PAVILION ` 3-5/8" MTL STUD - � 3-518" MTL TRACK SEALANT &BACKER ROD BOTH SIDES LLI SUITE 100 EDGE OF EXISTING FINISH FLOOR AS SCHEDULED F FLUSH NARROW G' HALF FG FULL DOOR ONLY DOOR WITH C DOOR WITH WINDOW SILL BEYOND (HINGED) GLASS -CITE GLASS- GLASS- A LITE LITE HALF LITE SLIDING PANEL �0'- 4 7/8" PARTITION AS FIELD SCHEDULED DOOR -HARDWARE LOCATIONS FRAME PROFILES VERIFY ALUM BREAK METAL E10 TYPE B1 & B4 - NR_3-5/8 MTL_6 ABV CLG 7320216TH STREET CLOSURE TO MATCH 1 1/2" - 1-0 SUITE 100 w STOREFRONT SYSTEM EDMONDS, WA 98026 AT DOORS WITH PUSH PLATES, AT DOORS WITH LEVERS OR ALUM CLOSURE PIECE, z PULLS, HANDLES, CUPS, AND KNOBS, AND SIMILAR PAINT TO MATCH WALL COLOR UNDERSIDE OF STRUCTURE ABOVE SIMILAR, NON -OPERABLE OPERABLE OPENING INTERIOR PARTITION `D OPENING HARDWARE: HARDWARE: CONFIGURATION, 2 1/2" MTL TRACK CONSTRUCTION, AND CEILING PER RCP LOCATE OPENING LOCATE OPENING FRAMING/HEADER WIDTH MAY VARY - - - ---- -� - - - - - - - - - - - - - - - - -- PERMIT/BID SET HARDWARE HERE HARDWARE HERE AS APPROPRIATE TO OPENING r 5/8 TYPE X GWB BOTH SIDES ---------- r-------r-1 _ _ _ _ - _ _ _ - _ SURFACE -MOUNTED ALUMINUM SLIDING DOOR FRAME 2" MIN LENGTH CLOSED CELL FOAM ADHESIVE CONT I DOOR CONSTRUCTION AND FULL -HEIGHT ACOUSTIC SEALANT BOTH SIDES. ACOUSTICAL BATT INSULATION PER WALL TYPE RECEIVED CONFIGURATION MAY VARY 2-1/2" MTL STUD I I I I I ALUM WINDOW MULLION PARTITIONPROFI EO NO FASTALIGN ETH EXISTING NERS RS ARE TOINDOW 2-1/2" MTL TRACK 11/8/24 I I HEAD PENETRATE EXISTING MULLION OR SILL IN THIS INSTALLATION. SEALANT &BACKER ROD BOTH SIDES CITY OF EDMONDS IR i o>00 FINISH FLOOR AS SCHEDULED DEVELOPMENT - I - (ALUMINUM) --------�_ - PART I T' I�r� D&KF � Ili i I (ALUMINUM) LATCH -SIDE JAMB I U--- -----1 33/4 JAMBS GAGE D7 TYPICAL PARTITION AT MULLION DOORS z 3" = 1'-01, n n c10 TYPE oB6 - NR_2-1/2 MTL_6 ABV CLG i w � --- DOOR LEAF INCLOSED POSITION O I I I Cl) I a (SHOWN DASHED) —+---- ----- —, —+---------�—, o ; 1 ; ;� ISSUANCE I---- ----J I I--- -----J I Lq a I I I II LATCH SIDE JAMB No. Description Date o z 1 PERMIT / BID SET 11/08/2024 INTERIOR PARTITION PER PLANS - w I I I I z wa UNDERSIDE OF STRUCTURE ABOVE CONSTRUCTION, CONFIGURATION, v AND WIDTH MAY VARY w w p0 I I II LOCATION OF DOORS ON FLOOR PLANS ADJACE WALL, WHERE OCCURS o I i ii 2 1/2" MTL TRACK 0 Q w I I II ANCHORS PER FRAME SUPPLIER z 0 0 I I II U UU I I I '� I i ii CEILING PER RCP ACOUSTICAL INSULATION IN FRAME w I I II o WHERE PARTITION HAS ACOUSTICAL � INSULATION v DOOR LEAF IN FULLY ACOUSTICAL BATT INSULATION PER WALL TYPE WRAP -AROUND HOLLOW -METAL FRAME, i I OPENED POSITION FIRE -LABELED AT FIRE -RATED a 5/8" TYPE "X" GWB (1) LAYER. EXTEND TO OPENINGS. FOR TYPICAL FRAME STRUCTURE ABOVE. I w I I J I DIMENSIONS, SEE DETAIL THIS SHEET. a (ALUMINUM) GUIDE SIDE JAMB o i ii i z 2-1/2" MTL STUD z Lu o I I \ Q ii i w i I FLOORING TRANSITION ALIGNED w Q i i i i U I II I a I I FINISH FLOOR AS SCHEDULED 0 o I II I o I WITH DOOR -SIDE OF JAMB PARTITION AS % z I I I I z z I II I = I - SCHEDULED w w w i i i i w w DOOR (LEAF) - CONSTRUCTION AND Z DOOR GUIDE MOUNTED TO - 31/8' w ao � I I I I AT SWING DOORS AND \ wo I II I CONFIGURATION MAY VARY U- I I i SUBFLOOR PER MFR. CUT FLOORING - 71 I I I I I II I AT SLIDING BARN- 16 GAGE � I I I I POCKET DOORS: WHERE I II I j AROUND MOUNTING PLATE OR a "� I I I OPENING LOCATION IS NOT Z) = I II TYPE DOORS: _- JAMB STUD I TYPE G2 - NR FURR 2-1/2��MTL 6" ABV CLG w 0 I I I I 0 0 I II WHERE OPENING I MOUNT PLATE ATOP FLOORING AS 0 I I I DIMENSIONED ON PLANS, o o I I RECOMMENDED BY MFR _ = cn I I I I LOCATE OPENING 6" FROM w � I ii i LOCATION IS NOT ALUM BREAK METAL B10 — — CLOSURE TO MATCH 1 112" = l'-0" U I I I I U I II I 1 GUIDE -SIDE JAMB STOREFRONT SYSTEM w w DIMENSIONED ON o J I I I CROSSING PARTITION, AS � � I I I - m I i i i INDICATED I I PLANS, LOCATE _ I I I I I ii i OPENING 6" FROM co i i i I CROSSING I UNDERSIDE OF STRUCTURE ABOVE CD PARTITION, AS i (ALUMINUM) JAMB i (WOHEORING RE OCCURS)ALIGNEDN I I INDICATED THROAT DIMENSION VARIES o I n I I (SEE PARTITION TYPE) ¢ ? i BEYOND j WITH DOOR -SIDE OF JAMB 3 5/8" MTL TRACK w�� 4 1/2" TO 6 1/2" FOR NON-WRAP- 0I DOOR GUIDE w AROUND FRAME AT CMU WALLS 11 ° - 2" MIN LENGTH CLOSED CELL FOAM CEILING PER RCP o P ADHESIVE CONT FULL -HEIGHT ACOUSTIC w O a °a - a a . U) 1/2" J Q w P a°Y <a ' P a SILL SEALANT BOTH SIDES. = a "' _ TF ALUM WINDOW MULLION ACOUSTICAL BATT INSULATION PER WALL TYPE _ a a PARTITION TO ALIGN WITH EXISTING Cn o ¢ _ WINDOWSILL PROFILE. NO o _ Q EDGE OF EXISTING v� WINDOW SILL BEYOND FASTENERS ARE TO PENETRATE 5/8" TYPE "X" GWB (1) LAYER. EXTEND TO PROJECT INFORMATION STRUCTURE ABOVE. o EXISTING MULLION OR SILL IN THIS PROJECT NUMBER: 24034 INSTALLATION. Q FIELD 3-5/8" MTL STUD PROJECT LEAD: JLO 00 >00 r7 a VERIFY FINISH FLOOR AS SCHEDULED DRAWN BY: JLO/GMD - 4 1 /4" co SHEET NO N LO TYPICAL PARTITION JOG AT MULLION TYPE G3 - NR FURR_3-5/8"MTL_FULL HEIGHT LO 0 1 15/16" VARIES 1 15/16" a3" = 1'-0" A10 1 1/2" = 1'-0" eo A3ml 1 1 2 3 1 4 5 6 7 1 8 9 1 10 11 1 Y x c� U- J 1 2 A10 E10 i ` 5.1 5.1 i i v PL-1 SSM-1 PL-1 SSM-1 H1 100 WAITING ROOM - N 3/8" = 1'-0" 24 34 MA/RN WORK - W 24 3/8" =1'-01, 3 uvv rrIVLL (I 001RECEPTION - S 3/8" = 1'-01, 4 5 6 7 8 r L- I JJIVI- I r L- 1 JJIVI- I 109 MA/RN WORK - E 3/8" = 1'-0" F3 0-2 Ml 3027M 302M 302 302 3001 F30-01 36 36 36 F30-21 302 302 36 36 24 24 30 30 30 30 24 30 30 30 20 20 PLAM SOFFIT \ 15 15 15 30 30 30 15 15 15 15 PLAM SOFFIT VALANCE VALANCE VALANCE 15 15 15 � All- v � 0004 III I CD 102 102 L PRINTER 36 36 0 34 34 PLAM COUNTERTOP 24 24 101 A WORK ROOM ELEV c.� m a a (V (V co 0 (V V CV O N W 3/8" = 1'-01, EXAM ROOM ACCESSORY PLACEMENT II ° BETWEEN GEL 6" UNLESS 46 BETWEEN GEL DISPENSER AND OTHERWISE DISPENSERS IGNITION SOURCE REQUIRED BY SUCH AS ELECTRICAL BUILDING OR HIGHEST SWITCH OR ELEC INSTUITUTION OPERABLE RECEPTACLE STANDARD O PART H M SIGN GEL DISPENSERS ROOM IDENTIFICATION SIGNAGE UC LIGHTING EYE WASH, S MECH SSM COUNTE C? 0001 0 o CC06 � 2_Qj 0 0 RTOP - N N \ / o 254 12221 20 36 34 34 24 24 108 SOILED UTILITY - E 3/8" = 1'-01, MTG-HEIGHT WHERE FIRE EXTINGUISHER ONE IS INDICATED AND CABINET (FEC) FIRE EXTINGUISHER HIGHEST PART OF (WALL-MTD WITH BRACKET) (FE) HOOK OR MTG CH ° PLATE WHERE 0 SECOND IS CH INDICATED C bo � v 00 v COAT HOOKS & ROBE HOOKS FIRE EXTINGUISHERS PAPER SOAP TOWEL DISPENSER DISPENSER -------- EXAM CASEWORK (MAY OCCUR UNDER w WALL-MTD ACCESSORIES) ACCESSORIES AT EXAM ROOMS 0 CV TOILETS AND DRINKING FOUNTAINS (AND WATER COOLERS) - TYPICAL CLEARANCES AND MOUNTING LOCATIONS 54" MIN SIGN IDENTIFYING 11 GRAB BAR ACCESSORY ACCESSORY BACK -WALL TOILET FOR "MEN" OR HIGHEST LOW POINT OF 42" MIN LOCATIONS ON 42" MAX LOCATIONS ON 42" MAX LOCATIONS ON 12" MIN GRAB BAR "WOMEN", AND OPERABLE PART REFLECTIVE 12" MAX GRAB -BAR WALL GRAB -BAR WALL „ NO -GRAB -BAR WALL24" MIN LOCATION „ / INCLUDING A OR OUTLET ON (MIRROR) SURFACE 24 MIN 24 MIN 9„ T012. PICTOGRAM, AND ACCESSORY 139" TO41" GRAB BARS WILL TOP OF BAR 4L TPD (TYPE MANUAL / INCLUDING TEXT WITH PTD MAY VARY) OCCUR ONLY AT FLUSH (WHERE i BRAILLE SD VGB AMBULATORY OCCURS) ON - - PTD __ HGB BOTTOM OF BAR z ACCESSIBLE STALL OPEN SIDE - - -- L_:;7�7,j AL z (�________� z I I HIGHEST ❑---� z _ z BRAILLE LINE TOP OF "' o z oo z [� z OM �� WR co OD o BAR ~ tSCD , LOWEST N M rPW Cl) M SNR SNR M BRAILLE LINE MOUNTING HEIGHTS FOR TOILET -STALL ACCESSORIES AND PLUMBING FIXTURES (ACTUAL SITUATIONS MAY BE MIRROR -IMAGE OF THOSE INDICATED) TOILET -ROOM IDENTIFICATION SIGNAGE ACCESSORY HEIGHTS & LAVATORY HEIGHT 1 LnIVI I nlMLL 108 SOILED UTILITY - S 3/8" = 1'-0" PLAM SOF PLAM Cl 222 1 F25-41222 30 24 30 34 34 34 24 24 24 121 CLEAN UTILITY - E 3/8" = 1'-0" 9 TILE AT FIREPLACE BUMP OUT D9 120 CORRIDOR "B" - S 3/8" = 1'-01, 10 11 INTERIOR ELEVATION SYMBOLS 000 — CABINET TAG INDICATING CABINET TYPE PER AMERICAN WOODWORKING INSTITUTE (AWI) STANDARDS 12 ► WIDTH IN INCHES 12 - HEIGHT IN INCHES 12 DEPTH IN INCHES DESC DESCRIPTION OF MODIFICATION, WHERE OCCURS © PROVIDE LOCK, WHERE INDICATED PL-3 MATERIAL TAG, SEE FINISH SCHEDULE t 425.778.1530 21911 76th Ave W. Ste 210 98 WA026 ABBREVIATIONS USED ON THIS AND OTHER ELEVATION SHEETS INCLUDE THE FOLLOWING: Info f 425.774.7803 Edmonds ends@tgbA 9CO26 CH COAT HOOK www.tgbarchitects.com DF DRINKING FOUNTAIN EWC ELECTRIC WATER COOLER FEC FIRE EXTINGUISHER CABINET GB GRAB BAR NCA NURSE CALL ALARM NCL NURSE CALL LIGHT NCP NURSE CALL PULL CORD PTD PAPER TOWEL DISPENSER PW PIPE WRAP (INSULATION) SD SOAP DISPENSER SNV SANITARY NAPKIN VENDING SNR SANITARY NAPKIN RECEPTACLE TPD TOILET PAPER DISPENSER TSCD TOILET SEAT COVER DISPENSER WR WASTE RECEPTACLE gb architects REGISTERED TECT L KKENT G STATE OF WASI"TON SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT INTERIOR'. CES DEPARTMENT ELEVATIONS I66UANU— No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: JLO DRAWN BY: JLO SHEET NO A4mlO 1 1 2 3 1 4 5 6 7 1 8 7 10 11 1 c� 0003 0004 1 _ EXAM ROOM #11 E3 1 55 CUBICLE CURTAIN 8 A4.11 E5 E6 CC06 C I I � � w U m ENLARGED - TYPICAL EXAM ROOM 2 3/8" = 1'-0" *TYPICAL - EXAM ROOMS #5, #6, #7, #8, #9, #10 *SIMILAR - EXAM ROOMS #1, #2, #3, #4 WP-1 0 v 3 4 3'-0" SEE FF&E PLAN 0004 F5 NURSE CALL, SEE ELEC �---� 5.1 ,� TPI I I 111= � — 00II03 u -1-- ul'I pl 0005 I I LI I TYPICAL EXAM - N E3 3/8' =1' o° / B8 A4.11 B5 - - C04 CO3 CC 4 I TOILET #1 CC03 01 TOILET #2/ 122 C \ 123 -- 0001 C 6 j C 9 09 \ / CC 6 0001 r CCO2 CCO2 CC05 C 0 / e f 6=� ILA OB1 ENLARGED PLAN - TOILET 122 & TOILET 123 3/8" = V-0" TYPICAL EXAM - E 3/8" I I i CCO A5 5.1 *123 TOILET - MIRROR OB4 122 TOILET #1 - N 3/8" = 1'-0" 5 I % A5 6 SSM WP-1 COUNT[ I 0 v *123 TOILET - MIRROR OB5 122 TOILET #1 - E 3/8" = V-0" N ~_ TOILETS AND DRINKING FOUNTAINS (AND WATER COOLERS) - TYPICAL CLEARANCES AND MOUNTING LOCATIONS U W O � b 54" MIN -SIGN IDENTIFYING FZ 11 GRAB BAR ACCESSORY ACCESSORY BACK -WALL TOILET FOR "MEN" OR HIGHEST LOW POINT OF 42" MIN LOCATIONS ON 42" MAX LOCATIONS ON 42" MAX LOCATIONS ON 12" MIN GRAB BAR "WOMEN", AND OPERABLE PART REFLECTIVE 12" MAX GRAB -BAR WALL „ GRAB -BAR WALL „ NO -GRAB -BAR WALL 24" MIN LOCATION „ �' INCLUDING A OR OUTLET ON (MIRROR) SURFACE 24 MIN 24 MIN 9 T012 . PICTOGRAM, AND ACCESSORY 0 39" TO 41" GRAB BARS WILL TOP OF BAR TPD (TYPE MANUAL / INCLUDING TEXT WITH PTD Cn n OCCUR ONLY AT SD FLUSH (WHERE i BRAILLE VGB MAY VARY) AMBULATORY OCCURS) ON - - - PTD ACCESSIBLE STALL OPEN SIDE - - ---- -- I I I, BOTTOM OF BAR I HGB z z HIGHEST BRAILLE LINE TOP OF "' O ❑ z oo ❑ z co [� z O �� OD WR C)BAR o0 ~ tSCD , LOWEST "' N M PW SNR SNR BRAILLE LINE co 1 1 7 o MOUNTING HEIGHTS FOR TOILET -STALL ACCESSORIES AND PLUMBING FIXTURES (ACTUAL SITUATIONS MAY BE MIRROR -IMAGE OF THOSE INDICATED) TOILET -ROOM IDENTIFICATION SIGNAGE ACCESSORY HEIGHTS & LAVATORY HEIGHT v N O N I CC01 302 30 30 101 24 34 24 E6 TYPICAL EXAM CASEWORK 3/8 -1 0 7 *123 TOILET - MIRROR OB7 122 TOILET #1- S 3/8" = V-0" EXAM ROOM ACCESSORY PLACEMENT ,- 6" BETWEEN GEL 6" UNLESS BETWEEN GEL DISPENSER AND OTHERWISE DISPENSERS IGNITION SOURCE REQUIRED BY SUCH AS ELECTRICAL BUILDING OR HIGHEST SWITCH OR ELEC INSTUITUTION OPERABLE RECEPTACLE STANDARD n SIGNO GEL DISPENSERS P II ROOM IDENTIFICATION SIGNAGE CUBICLE CU AND TRACK MTG-HEIGHT WHERE ONE IS INDICATED HIGHEST PART OF HOOK OR MTG- CH ° PLATE WHERE �_CH ° SECOND IS INDICATED _ 0 *� 00 ----a COAT HOOKS & ROBE H00 8 9 TYPICAL EXAM - W 3/8" =1' 0" *123 TOILET - MIRROR OB8 122 TOILET #1 - W 3/8" = 1'-0" FIRE EXTINGUISHER AND CABINET (FEC) FIRE EXTINGUISHER (WALL-MTD WITH BRACKET) (FE) 'v I. FIRE EXTINGUISHERS TIM PAPER SOAP TOWEL DISPENSER DISPENSER Ll L EXAM CASEWORK � (MAY OCCUR UNDER w WALL-MTD ACCESSORIES) I, ACCESSORIES AT EXAM ROOMS 10 11 INTERIOR ELEVATION SYMBOLS 000 - CABINET TAG INDICATING CABINET TYPE PER AMERICAN WOODWORKING INSTITUTE (AWI) STANDARDS 12 ► WIDTH IN INCHES 12 HEIGHT IN INCHES 12 - DEPTH IN INCHES DESC - DESCRIPTION OF MODIFICATION, WHERE OCCURS PROVIDE LOCK, WHERE INDICATED PL-3 MATERIAL TAG, SEE FINISH SCHEDULE t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 ABBREVIATIONS USED ON THIS AND OTHER ELEVATION SHEETS INCLUDE THE FOLLOWING: Info@tgbarchltects.com CH COAT HOOK www.tgbarchitects.com DF DRINKING FOUNTAIN EWC ELECTRIC WATER COOLER FEC FIRE EXTINGUISHER CABINET GB GRAB BAR NCA NURSE CALL ALARM NCL NURSE CALL LIGHT NCP NURSE CALL PULL CORD PTD PAPER TOWEL DISPENSER PW PIPE WRAP (INSULATION) SD SOAP DISPENSER SNV SANITARY NAPKIN VENDING SNR SANITARY NAPKIN RECEPTACLE TPD TOILET PAPER DISPENSER TSCD TOILET SEAT COVER DISPENSER WR WASTE RECEPTACLE FF&E SCHEDULE COORDINATION REQUIRED z = m 0 U U FF&E NO. DESCRIPTION "' w � a > m CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CC01 36 - GRAB BAR • CCO2 42 - GRAB BAR • CC03 18 - GRAB BAR (SEE ELEVATIONS FOR ORIENTATION) • CC04 TOILET PAPER DISPENSER CC05 TOILET SEAT DISPENSER CC06 PAPER TOWEL DISPENSER CC07 SIMPLIFIRE ALLUSION 40 - FIREPLACE INSERT • • CC08 COAT HOOKS (2) • CC09 SANITARY NAPKIN DSPOSAL OWNER FURNISHED / CONTRACTOR INSTALLED 0004 WALL MOUNTED COMPUTER ARM • • OWNER FURNISHED / OWNER INSTALLED 0001 SOAP DISPENSER 0002 DESKTOP PRINTER • 0003 Midmark 626 Barrier -Free Power Examination Table • 0004 PRINTER • 0005 PHYICIANS TOOL 0006 SCALE • • 0007 METRO RACKS gb architects *3626 TEREDITECT STATE OF WASHNGTON SWEDISH -EDMONDS MEDICAL PAVILION - S U ITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11 /8/211 E N LAR v ED EFoLAN S DEVELOPMENT & I N T E I:?in : =EPARTMENT ELEVATIONS 155UANUL No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: JLO DRAWN BY: JLO SHEET NO A4ml 1 1 1 2 3 1 4 5 6 7 8 7 10 11 1 1 2 3 1 4 5 6 7 8 9 10 11 2 c� w J 0 U EXISTING COMPOSITE CONSTRUCTION FIREPROOFING, IF OCCURS d• - 4 - d 4" X 4" X 6" LONG 43 MIL ANGLE FASTENED TO STUD BRACE WITH 2 #10 ' ®' SHEET -METAL SCREWS .// - IF EXISTING FIREPROOFING: / DEMOLISH FIREPROOFING ONLY 1 AS NECESSARY TO ATTACH NEW 1 PARTITION HEAD OR BRACES. REPAIR/PATCH FIREPROOFING AFTER ATTACHMENT, SHADED, TYPICAL. 2 1/2" METAL STUD DIAGONAL BRACES (ALTERNATE WHERE POSSIBLE) @ 44" OC I BRACE FASTENED TO VERTICAL STUD FRAMING WITH 2 #10 SHEET -METAL SCREWS I BLOCKING AS NECESSARY TO COMPLETE GYPSUM BOARD PERIMETER NAILING I I I UNLESS OTHERWISE INDICATED 1 3 5/8" METAL STUDS @ 16"OC I I I I I SOFFIT OF METAL FRAMING AT 16" OC I I I I I PER CEILING PLANS C3030.22 SOFFIT AT WALL - TO COMPOSITE SLAB 1 1/2" = V-0" SUPPORT CEILING METAL STUDS/JOISTS AND TRACKS COMPLYING WITH ASTM C-1007-11a. --------------- ---------- ----- AND O INSTALL AND FINISH GYPSUM BOARD PER ASTM STANDARD C-840-11 AND GA-216-13. ----------------- OR SUPPORT CEILING ON GRID -TYPE SUSPENSION SYSTEM COMPLYING WITH ASTM C-754-11 AND GA-216-13. AND INSTALL AND FINISH GYPSUM BOARD PER ASTM STANDARD C-840-11 AND GA-216-13. OR SUPPORT CEILING ON SUSPENSION SYSTEM (WIRES, HAT -CHANNELS AND C-CHANNELS) COMPLYING WITH ASTM C-754-11 AND GA-216-13. INSTALL AND FINISH GYPSUM BOARD PER ASTM STANDARD C-840-11 AND GA-216-13. C3030.18 CONSTRUCTION OF GYPSUM BOARD CEILINGS 3"=1'0" EXISTING COMPOSITE CONSTRUCTION FIREPROOFING, IF OCCURS d 9 "d 4" X 4" X 6" LONG 43 MIL ANGLE FASTENED TO STUD BRACE WITH 2 #10 I1 SHEET -METAL SCREWS o `III I 0 11 / 01 I IF EXISTING FIREPROOFING: DEMOLISH FIREPROOFING ONLY AS NECESSARY TO ATTACH NEW PARTITION HEAD OR BRACES. REPAIR/PATCH FIREPROOFING AFTER ATTACHMENT, SHADED, TYPICAL. 2 1/2" METAL STUD DIAGONAL BRACES (ALTERNATE WHERE POSSIBLE) @ 44" OC BRACE FASTENED TO STUD HEADER WITH 2 #10 SHEET - METAL SCREWS BLOCKING AS NECESSARY TO COMPLETE GYPSUM BOARD PERIMETER NAILING CEILING AS SCHEDULED I I I I II II II II UNLESS OTHERWISE INDICATED - 3 5/8" METAL STUDS @ 16"OC 4 7/8" C3030.20 SOFFIT/HEADER - TO COMPOSITE SLAB WALL -ANGLE CONFIGURATION, AND PANEL TYPE MAY VARY RBVS OR FRL WAINSCOT ADHERED O TO GYPSUM BOARD INSTALL COLOR -MATCHED ` CAULK (AS RECOMMENDED BY MFR) AT INSIDE CORNERS CORNER BEAD PREVENTS CLEAN _ RVS OR FRL WAINSCOT ADHERED TO PLUMB ATTACHMENT OF CEILING _ GYPSUM BOARD - WALL ANGLE ILL _ - GYPSUM BOARD ILL C3010.16 WAINSCOT - RVS/FRL - INSIDE CORNER ( NO TRIM) J5 12" = C3030.09 ACP TO GYPSUM BOARD 12" = 1'-0" EXISTING COMPOSITE CONSTRUCTION FIREPROOFING, IF OCCURS - - - - a d d II II II � II II / II 2 1/2" METAL STUD DIAGONAL BRACES 1i (ALTERNATE WHERE POSSIBLE) @ 44" OC BRACE FASTENED TO VERTICAL ®, STUD FRAMING WITH 2 #10 / II III I I I I SHEET -METAL SCREWS BLOCKING AS NECESSARY TO 11 COMPLETE GYPSUM BOARD 1 II 1i PERIMETER NAILING II II II II II II II II II II II II II UNLESS OTHERWISE INDICATED - 1i 3 5/8" METAL STUDS @ 16"OC II II II II II II II II II II II II SOFFIT OF METAL FRAMING AT 16" OC ill I I I II PER CEILING PLANS C3030.21 SOFFIT (FLOATING) - TO COMPOSITE SLAB 1 1/2" = V-0" 5" 7" I I I I I I I TO GWB FIREPLACE SECTION BLOCKING AS NECESSARY COVE -TYPE LIGHT FIXTURE WITH WALL CLIP SEE ELECTRICAL GWB SOFFIT PER CEILING PLAN z Q J d z J_ w 0 ry w d c� w 0 3-5'8" METAL STUD WITH 5/8" J TILE BACKER BOARD TILE FINISH FIREPLACE INSERT BASIS OF DESIGN: SIMPLIFIRE ALLUSION 40 - MODEL: SF-ALL40-BK INSTALLATION: FULLY RECESSED FIRE BED MATERIAL: DRIFTWOOD EXISTING PARTITION NO BASE AT TILE FIREPLACE SURROUND PROVIDE CLEAN TRANSITION BETWEEN TILE AND CARPET GYPSUM BOARD STANDARD MILLED -FINISH ALUMINUM J-CHANNEL TRIM, PER MANUFACTURER Q FRL OR RVS (AS SCHEDULED) ADHERED TO GYPSUM BOARD HEADWALL FRL TRIM (PLAN VIEW) C3010.13 WAINSCOT - RVS/FRL - TOP WITH TRIM F5 12" = 1'-0" PARTITION AS SCHEDULED WALL FINISHES AND/OR WALL PROTECTION TO BE APPLIED PRIOR TO ATTCHMENT OF CORNERGUARD STAINLESS -STEEL CORNERGUARD WITH WINGS - FASTEN WITH MFR- RECOMMENDED ADHESIVE OR TAPE, UNLESS OTHERWISE INDICATED OR SPECIFIED TERMINATE CORNERGUARD AT TOP OF WALL -BASE (WALL -BASE VARIES) 1 1/2" EACH LEG - UNLESS OTHERWISE INDICATED C3010.06 CORNER GUARD - STAINLESS STEEL aS NECESSARY LIGHT FIXTURE WITH WALL CLIP RICAL :ILING PLAN J7 LIGHTCOVE DETAIL /o 0 VINYL TRIMS AND CORNER GUARDS BEYOND (WHERE OCCUR) TO ABUT TO FLOORING CAP MILLED FINISH ALUMINUM FLOORING CAP RESILIENT FLOORING TURNED UP ONTO WALL (FLASH -COVED) GYPSUM BOARD F7 C3010.21 WAINSCOT - BOTTOM (AT FLASH -COVE) 12"v-011 MFR'S STANDARD SQUARE -TOP METAL CAP/TRIM OR SIMILAR SELF -COVED (FLASH - COVED) VINYL/RUBBER w FLOORING (ADHERED v WITH MFR- z RECOMMENDED w ADHESIVE w GYPSUM BOARD SUBSTRATE o Cn w MFR'S SMALLEST RECOMMENDED SIZE FILLET STRIP C3010.32 WALL BASE - SELF -COVED RESILIENT 6" = 1'-01, 12" = V-0" CERAMIC TILE - SIZE AND CONFIGURATION MAY VARY METAL BLOCKING IF NECESSARY FOR FASTENING OF TILE SCREED GROUT TILE SCREED, SIMILAR TO SCHLUTER SCHIENE, ALUMINUM FINISH. PROVIDE SCREED AT TOP AND BOTTOM OF RAIL, AND AT ALL EXPOSED ENDS (ENDS THAT DO NOT RETURN TO A CROSSWALL OR TO CASEWORK). SEAL ANY GAP AS NECESSARY WALL BASE, AS SCHEDULED C3010.41 BOTTOM OF TILE WAINSCOT - AT FLASH COVE 1 1/2" = V-0" 1" = 1'-0" �J 12" = 1'4' a J10 CUBICLE -CURTAIN TRACK (CCT) 12-10 RECEPTION DESK SECTION - 3411H SUSPENDED CEILING GRID ACOUSTICAL CEILING PANEL SHIM/SPACER BETWEEN TRACK AND RUNNER (BEYOND) TO PREVENT DISPLACEMENT OF CEILING PANELS, AT TEGULAR PANELS ONLY CUBICLE -CURTAIN TRACK (SIMILAR TO KIRSCH 9600 SERIES, CLEAR ALUMINUM FINISH), WITH CARRIERS, EYES, AND HOOKS FOR CURTAIN PLAM PANELS ON PLYWOOD SSM PLAM PANELS ON PLYWOOD tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com *KFNT TERED TECT STATE OF WASHNGTON SWEDISH -EDMONDS MEDICAL PAVILION - S U ITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DETAILS 155UANUL No. Description Date 1 PERMIT / BID SET 11/08/2024 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 N co 0 N V N 0 N 1 1 2 3 1 4 5 6 7 7 RECEPTION DESK- SECTION 1" SHEET NO A5ml 0 10 11 1 2 3 4 5 1 6 7 8 9 1 10 11 CONTROLS PG AIR PRESSURE GAUGE O AIR SAMPLING POINT coz CARBON DIOXIDE SENSOR Y co CARBON MONOXIDE SENSOR cc COMBUSTIBLE GAS SENSOR cr CURRENT SENSOR cr CURRENT TRANSMITTER WITH LEAD O DEWPOINT SENSOR oPs DIFFERENTIAL PRESSURE SENSOR DPT DIFFERENTIAL PRESSURE TRANSMITTER FM FLOW METER Fs FLOW SWITCH FT FLOW TRANSMITTER Fz FREEZE STAT Ho HAND SWITCH O HUMIDITY SENSOR Lc LEVEL CONTROL Ls LIMIT SWITCH LPI LOOP POWER INDICATOR Nox NITROGEN OXIDE SENSOR O OCCUPANCY SENSOR oz OXYGEN SENSOR Pi POSITION INDICATOR Ps PRESSURE SENSOR O REFRIGERANT SENSOR RH RELATIVE HUMIDITY SENSOR = O RELAY O ROOM HUMIDITY SENSOR sP STATIC PRESSURE SENSOR rs TEMPERATURE SENSOR O THERMOSTAT ❑r THERMOSTAT WITH GUARD rvo TOTAL VOLATILE ORGANIC COMPOUND SENSOR vis VIBRATION SENSOR AFs AIR FLOW SWITCH P CURRENT TO PRESSURE E/P ELECTRIC/PNEUMATIC scR SILICON CONTROLLED RECTIFIER rcP TEMPERATURE CONTROL PANEL FTEcl TERMINAL EQUIPMENT CONTROLLER SENSOR WELL ALARM HORN ® ALARM BEACON Ai ANALOG INPUT Ao ANALOG OUTPUT o DIRECT INPUT D0 DIRECT OUTPUT sr STARTER FD VARIABLE FREQUENCY DRIVE X NON MOTORIZED VALVE M❑-g TWO WAY MOTORIZED VALVE THREE WAY MOTORIZED VALVE x TWO WAY SOLENOID VALVE NC O)o THREE WAY SOLENOID VALVE NO CM TWO WAY PNEUMATIC VALVE NC 0 THREE WAY PNEUMATIC VALVE NO ® PUMP OS DUCT SMOKE DETECTOR O DUCT SMOKE DETECTOR AIR VALVE W W U J Q U z Q U w J w > w J d w U) 0 w 3 m v Cl) O v (V V (V O CV U) H U w 0 ry a U) ry U O a 0 Q a CONTROLS ELECTRIC HEATING COIL U UNITARY COOLING COIL U = UNITARY HEAT RECOVERY COIL FILTER AIR BLENDER ENERGY WHEEL PLATE ENERGY RECOVERY COIL AIR FLOW MEASURING STATION AIR FLOW PROBE BACKDRAFT DAMPER REFRIGERANT HOT GAS REFRIGERANT SUCTION ° NC DAMPER ACTUATOR - ELECTRIC Nc DAMPER ACTUATOR - ELECTRIC CENTRIFUGAL FAN i I PROP FAN PLENUM FAN \V\V\V\V\V HUMIDIFIER ENERGY CORE 0 ENERGY CORE ETHERNET CONNECTION CONTACT DDC PANEL COMPUTER PLUMBING SYSTEMS PIPE SIZE -XX--------- PIPING ROUTED BELOW SLAB OR GRADE AV ACID VENT AW ACID WASTE BBD BOILER BLOWDOWN CA(##) COMPRESSED AIR (NOMINAL PRESSURE) CD(P) CONDENSATE DISCHARGE PUMPED CD CONDENSATE DRAIN DI DIONIZED WATER DIR DIONIZED WATER RECIRCULATING DW DISTILLED WATER DCW- - DOMESTIC COLD WATER DCW(S) DOMESTIC COLD WATER SOFTENED DHW- - - - DOMESTIC HOT WATER DHWR- - - - - DOMESTIC HOT WATER RECIRCULATION D DRAIN GW GREASE WASTE H HUMIDIFICATION LV LABORATORY VENT LW LABORATORY WASTE G NATURAL GAS (LOW PRESSURE) GD GARAGE DRAINAGE GV NATURAL GAS VENT MPG MEDIUM PRESSURE GAS NPCW NON -POTABLE COLD WATER NPCW(S) NON -POTABLE COLD WATER SOFTENED NPHW NON -POTABLE HOT WATER NPHW(S) NON -POTABLE HOT WATER SOFTENED PTS PNEUMATIC TRANSPORT PG PROPANE GAS RO REVERSE OSMOSIS ROR REVERSE OSMOSIS RECIRCULATION SL SAMPLING LINE SAN SANITARY DRAIN SAN(0) SANITARY DRAIN (OIL) SAN(P) SANITARY PUMPED SAN(RAD) SANITARY RADIOACTIVE ST STORM DRAIN ST(0) STORM DRAIN OVERFLOW ST(P) STORM DRAIN PUMPED VAC VACUUM (AIR) VAC(EX) VACUUM PUMP EXHAUST V VENT --------V(0) VENT (OIL) --------- V(SE) VENT (SEWAGE EJECTOR) 11011 PIPE INSULATION FIXTURE TRAP CB O CATCH BASIN MH O MAN HOLE RD 0 ROOF DRAIN FD 0 FLOOR DRAIN FFD0 FUNNEL FLOOR DRAIN -'-0--I ` TRAP PRIMER HOSE BIBB 0�1 PLUMBING FIXTURES PIPING SYSTEMS (HVAC) 2 1/2" PIPE SIZE BBD BOILER BLOWDOWN BFW BOILER FEED WATER BR BRINE RETURN BS BRINE SUPPLY CHWR CHILLED WATER RETURN CHWR(G) CHILLED WATER RETURN - GLYCOL CHWR(P) CHILLED WATER RETURN - PROCESS CHWS CHILLED WATER SUPPLY CHWS(G) CHILLED WATER SUPPLY - GLYCOL CHWS(P) CHILLED WATER SUPPLY - PROCESS CWR CONDENSER WATER RETURN CWR(CT) CONDENSER WATER RETURN - COOLING TOWER CSW CONDENSER WATER SUPPLY CWS(CT) CONDENSER WATER SUPPLY - COOLING TOWER DTR DUAL TEMPERATURE RETURN (HOT OR CHILLED) DTS DUAL TEMPERATURE SUPPLY (HOT OR CHILLED) FOF FUEL OIL FILL FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOV FUEL OIL VENT HWR HEATING WATER RETURN HWR(G) HEATING WATER RETURN - GLYCOL HWS HEATING WATER SUPPLY HWS(G) HEATING WATER SUPPLY - GLYCOL G NATURAL GAS GV NATURAL GAS VENT RAD RADON GAS REF(HG) REFRIGERANT HOT GAS REF(L) REFRIGERANT LIQUID REF(S) REFRIGERANT SUCTION REF(V) REFRIGERANT VENT RV RELIEF VENT S(##) STEAM (NOMINAL PRESSURE) CS(##) STEAM - CLEAN (NOMINAL PRESSURE) C(##) STEAM CONDENSATE (NOMINAL PRESSURE) PC(##) STEAM PUMPED CONDENSATE (NOMINAL PRESSURE) SV STEAM VENT � lip,, PIPE INSULATION WORK DEFINITION NEW WORK (N) EXISTING (E) ------ REMOVE EXISTING (D) �� REMOVE EXISTING EQUIPMENT (D) - - - FUTURE - - - - TEMPORARY, AS NOTED RELOCATE (R) ### KEY NOTE ### EQUIPMENT IDENTIFICATION CONNECTION TO EXISTING C DISCONNECT (CUT AND CAP) HVAC AIR FLOW ARROW 18"x12" 18"x12"� RECTANGULAR DUCT AND SIZE* 18"0 18-0� ROUND DUCT AND SIZE 18"x12" 0 18"x12" 0 FLAT OVAL DUCT AND SIZE' 18"x12" EXTERIOR DUCT TREATMENT' - 18"x12" 18"xl2"---q RECTANGULAR DUCT WITH ACOUSTIC LINING* B � 30"xl2" DUCT SECTION, SUPPLY AIR. APPLIES TO RECT., ROUND AND OVAL B DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL LA 171 DUCT SECTION, RETURN AIR. APPLIES TO RECT., ROUND AND OVAL DUCT SECTION, EXHAUST AIR. APPLIES TO RECT., ROUND AND OVAL III II/////I I IIIIIIII FLEXIBLE DUCT X ELBOW TURN, SUPPLY DOWN. APPLIES TO RECT., ROUND AND OVAL DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL IE DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL SUP CHANGE IN DUCT ELEVATION RISING IN DIRECTION INDICATED fE Nl CHANGE IN DUCT ELEVATION DROPPING IN DIRECTION INDICATED END CAP ELBOW, RECTANGULAR, SMOOTH RADIUS WITH SPLITTER VANES (0.25 R/W DEFAULT) ELBOW, RECTANGULAR, SMOOTH RADIUS WITHOUT VANES (1.5 R/W DEFAULT) ELBOW, ROUND, SMOOTH RADIUS (1.5 R/W DEFAULT) MITERED ELBOW, RECTANGULAR, WITHOUT VANES MITERED ELBOW, RECTANGULAR, WITH TURNING VANES ® RECTANGULAR TO ROUND TRANSITION REAL OBJECT SYMBOL PIPING COMPONENTS ISOLATION VALVE (GENERIC) z r'-', DUCT ACCESS DOOR (TOP, SIDE, BOTTOM) GATE VALVE GLOBE VALVE FLEXIBLE CONNECTION 1 BUTTERFLY VALVE NPS 6 AND LESS BUTTERFLY VALVE NPS 8 AND MORE BACKDRAFT DAMPER BDD 8� BALL VALVE PLUG VALVE CABLE OPERATED DAMPER COD -�- NEEDLE VALVE _ CHECK VALVE (GENERIC) MANUAL DAMPER BALANCING VALVE FLOW LIMITING VALVE MOTORIZED DAMPER ® �a PRESSURE REDUCING VALVE M 2-WAY o � �a 2-WAY CONTROL VALVE (GENERIC) PRESSURE INDEPENDENT REGULATOR 2-WAY Q �� TWO-WAY ELECTRIC CONTROL VALVE, BUTTERFLY TYPE CAR 3-WAY ® ow 6 6 3-WAY CONTROL VALVE (GENERIC) FIRE DAMPER 3-WAY THREE-WAY ELECTRIC CONTROL VALVE, BUTTERFLY TYPE $ SOLENOID 2-WAY CONTROL VALVE SMOKE DAMPER SOLENOID 3-WAY CONTROL VALVE FLOAT OPERATED VALVE ACTUATOR SMOKE AND FIRE DAMPER m- SAFETY OR RELIEF VALVE ,�J- ANGLE VALVE DUCT SILENCER/TRANSFER ELBOW �- BOILER STOP AND CHECK VALVE O CONTROL DEVICE (REFER TO CONTROLS LEGEND) o1�C� DOUBLE CHECK VALVE ASSEMBLY ® AIR FLOW MEASURING STATION (REFER TO CONTROLS LEGEND) MULTI -PURPOSE VALVE (SHUT-OFF, BALANCING AND CHECK) QUANTITY rYt�r� REDUCE PRESSURE BACKFLOW PREVENTER - TYPE --*- SUCTION DIFFUSER - SIZE (IN.) AIR OUTLET OR INLET TAG (REFER TO SCHEDULE) VOLUME (CFM) PUMP (GENERIC) Y-STRAINER (GENERIC) RECTANGULAR DIFFUSER, SUPPLY. ® STEAM TRAP (GENERIC) OPTIONAL ARROWS SHOW THE FLOW DIRECTION. AUTOMATIC AIR VENT �- MANUAL AIR VENT z RECTANGULAR REGISTER OR GRILLE, RETURN VACUUM BREAKER °�� SHOCK ABSORBER RECTANGULAR REGISTER OR GRILLE, EXHAUST e TEMPERATURE GAUGE o PRESSURE GAUGE ® ROUND DIFFUSER, SUPPLY 0 y TEMPERATURE AND PRESSURE TRAP LINEAR DIFFUSER SIGHT FLOW GLASS g SIDEWALL REGISTER OR GRILLE, SUPPLY 0 0 O -mg- FLEXIBLE CONNECTOR g SIDEWALL GRILLE, RETURN OR EXHAUST E � EXPANSION JOINT UC UNDERCUT DOOR - GUIDE DOOR GRILLE OR LOUVER X ANCHOR TRANSFER GRILLE OR LOUVER -0 FLOW ARROW COIL (REFER TO CONTROLS LEGEND) 1% PIPING SLOPE QUANTITY El El PIPE CAP TYPE PIPE BREAK - LENGTH (FT.) RADIATION HEATING TAG (REFER TO SCHEDULE) PIPE CROSS CAPACITY (MBH) o c PIPING ELBOW UP c PIPING ELBOW DOWN PIPING TEE UP PIPING TEE DOWN UNION CONNECTION T 0 0 FLANGED CONNECTION D D o ❑ CONCENTRIC REDUCER D D ECCENTRIC REDUCER Co 1 STANDARD CLEAN -OUT IN LINE END OF RUN STANDARD CLEAN -OUT THROUGH FLOOR END OF RUN STANDARD CLEAN -OUT THROUGH FLOOR IN LINE DIFFERENTIAL PRESSURE CONTROL VALVE Y-PATTERN MANUAL BALANCING/SHUT-OFF VALVE PRESSURE INDEPENDENT CONTROL VALVE ABBREVIATIONS EQUIPMENT IDENTIFICATION A/C AIR CONDITIONING UNIT AB-# AIR BLENDER AAV AUTOMATIC AIR VENT AC-# AIR COMPRESSOR ADA AMERICANS WITH DISABILITIES ACT ACU-# AIR CONDITIONING UNIT ADJ ADJUSTABLE ADS-# AIR AND DIRT SEPARATOR AFC ABOVE FINISHED CEILING AF-# AIR FILTER AFF ABOVE FINISHED FLOOR AHU-# AIR HANDLING UNIT AFG ABOVE FINISHED GRADE AS-# AIR SEPARATOR AFR ABOVE FINISH ROOF ATU-# AIR TERMINAL UNIT AHJ AUTHORITY HAVING JURISDICTION 134 BOILER AP ACCESS PANEL BCU-# BLOWER COIL UNIT APD AIR PRESSURE DROP BT-# BATH TUB AVG AVERGAGE CB-# CHILLED BEAM BAS BUILDING AUTOMATION SYSTEM CC-# COOLING COIL BDD BACKDRAFT DAMPER CH-# CHILLER BHP BRAKE HORSEPOWER CONV-# CONVECTOR BMS BUILDING MANAGEMENT SYSTEM CRU-# CONDENSATE RETURN UNIT BOD BOTTOM OF DUCT CT-# COOLING TOWER BOP BOTTOM OF PIPE CU-# CONDENSING UNIT BTU BRITISH THERMAL UNIT CUH-# CABINET UNIT HEATER BTUH BRITISH THERMAL UNIT PER HOUR CV-# CONTROL VALVE C/W COMPLETE WITH DAC-# DOOR AIR CURTAIN CAV CONSTANT AIR VOLUME DC-# DUST COLLECTOR CBV CIRCUIT BALANCING VALVE DCT-# DECONTAMINATION TANK CFM CUBIC FEET PER MINUTE DCVA-# DOUBLE CHECK VALVE ASSEMBLY DB DRY BULB TEMEPRATURE DF-# DRINKING FOUNTAIN dB DECIBEL(S) DG-# DOOR GRILLE dBA A -WEIGHTED DECIBLES DS-# DUCT SILENCER DDC DIRECT DIGITAL CONTROL DU-# DEHUMIDIFICATION UNIT DEG DEGREE DWH-# DOMESTIC WATER HEATER DIA10 DIAMETER E-# EXHAUST GRILLE / REGISTER / DIFFUSER DIFF DIFFERENTIAL EL-# EXPANSION LOOP DIV DIVISION ERC-# ENERGY RECOVERY COIL DN DOWN ERU-# ENERGY RECOVERY UNIT DWG DRAWING ES-# EMERGENCY SHOWER EA EXHAUSTAIR ETU-# EXHAUST TERMINAL UNIT EA (D) EXHAUST AIR, DISHWASH EWC-# ELECTRIC WATER COOLER EA (G) EXHAUST AIR, GENERAL EWS-# EYE WASH STATION EA (K) EXHAUST AIR, KITCHEN F(C)-# FAN CEILING EA (LAB) EXHAUST AIR, LABORATORY F(E)-# FAN EXHAUST EA (LD) EXHAUST AIR, LAUNDRY/DRYER F(LE)-# FAN LABORATORY EXHAUST EA (W) EXHAUST AIR, WASHROOM F(R)-# FAN RETURN EAT ENTERING AIR TEMPERATURE F(S)-# FAN SUPPLY EAV EXHAUST AIR VALVE F(T)-# FAN TRANSFER ECM ELECTRONICALLY COMMUNICATED MOTOR F-# FAN ED EXISTING TO BE DEMOLISHED (DEMOLITION PLANS) FCU-# FAN COIL UNIT EER ENERGY EFFICIENCY RATIO FD-# FLOOR DRAIN EG ETHELYENE GLYCOL FFU-# FAN FILTER UNIT EMCS ENERGY MANAGMENT CONTROL SYSTEM FPP-# FIRE PROTECTION PUMP ER EXISTING RELOCATED (NEW CONSTRUCTION PLANS) FPTU-# FAN POWERED TERMINAL UNIT ERL EXISTING TO BE RELOCATED (DEMOLITION PLANS) FTR-# FINNED TUBE RADIATOR ESP EXTERNAL STATIC PRESSURE FUR-# FURNACE EWT ENTERING WATER TEMPERATURE GFS-# GLYCOL FEED SYSTEM EXIST / E EXISTING (DEMOLITION PLANS) GSG-# GAS -FIRED STEAM GENERATOR(*) FC FAIL CLOSED H(C)-# HOOD (CANOPY) FLA FULL LOAD AMPERAGE H(HC)-# HOOD (HEAT AND CONDENSATE) FO FAIL OPEN H(I)-# HOOD (INTAKE) FP FIRE PROTECTION H(K)-# HOOD (KITCHEN) FPM FEET PER MINUTE H(R)-# HOOD (RELIEF) FPS FEET PER SECOND H(RH)-# HOOD (RANGE) FT FOOT/FEET H-# HUMIDIFIER GA GAUGE HC-# HEATING COIL GAL GALLON (US) HP-# HEAT PUMP GC GENERAL CONTRACTOR HRU-# HEAT RECOVERY UNIT GEO GEODETIC HT-# HYDROPNEUMATIC TANK GPM GALLONS PER MINUTE HX-# HEAT EXCHANGER HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER) LATU-# LAB AIR TERMINAL UNIT HP HORSEPOWER LAV-# LAVATORY HR HOUR MAC-# MEDICAL AIR COMPRESSOR HVAC HEATING / VENTILATING / AIR CONDITIONING MAU-# MAKEUP AIR UNIT HZ HERTZ MD-# MOTORIZED DAMPER IE INVERT ELEVATION MSK-# MOP SINK IEER INTEGRATED ENERGY EFFECIENCY RATIO MV-# MIXING VALVE IN INCHES MVP-# MEDICAL VACUUM PUMP IN WG INCHES WATER GAUGE P-# PUMP IPLV INTEGRATED PART LOAD VALUE PDU-# POOL DEHUMIDIFICATION UNIT kW KILOWATT PRV-# PRESSURE REDUCING VALVE kWh KILOWATT HOUR PTAC-# PACKAGED TERMINAL AIR CONDITIONER LAT LEAVING AIR TEMPERATURE R-# RETURN AIR GRILLE / REGISTER / DIFFUSER LBS POUNDS RD-# ROOF DRAIN LF LINEAR FEET RH-# RANGE HOOD LWT LEAVING WATER TEMPERATURE RP-# RADIANT PANEL M METER RPBP-# REDUCED PRESSURE BACKFLOW PREVENTER MAX MAXIMUM RTU-# ROOFTOP UNIT MBH THOUSAND OF BTUH S-# SUPPLY GRILLE / REGISTER / DIFFUSER MCA MINIMUM CIRCUIT AMPS SH-# SHOWER MERV MINIMUM EFFECIENCY REPORTING VALUES SK-# SINK MFR MANUFACTURER SPC-# SOLAR PANEL COLLECTOR MIN MINIMUM SSF-# SIDE STREAM FILTER MOP MAXIMUM OVERCURRENT PROTECTION T(B)-# TANK (BUFFER TANK) MWT MEAN WATER TEMPERATURE T(E)-# TANK (EXPANSION TANK) N/A NOT APPLICABLE T(H)-# TANK (HYDRO PNEUMATIC TANK) NC NOISE CRITERIA T(S)-# TANK (STORAGE TANK) NC NORMALLY CLOSED T-# TRANSFER AIR GRILLE NIC NOT IN CONTRACT UH-# UNIT HEATER NO NORMALLY OPEN UR-# URINAL NPS NOMINAL PIPE SIZE USG-# UNFIRED STEAM GENERATOR NTS NOT TO SCALE UV-# UNIT VENTILATOR CIA OUTSIDE AIR VA-# VALVE OFCI OWNER FURNISHED, CONTRACTOR INSTALLED VFD-# VARIABLE FREQUENCY DRIVE OFE OWNER FURNISHED EQUIPMENT WC-# WATER CLOSET OF01 OWNER FURNISHED / OWNER INSTALLED WS-# WATER SOFTENER PG PROPYLENE GLYCOL L-# LOUVER POE POINT OF ENTRANCE POS POINT OF SERVICE PPM PARTS PER MILLION PSI POUNDS PER SQUARE INCH PSIA POUNDS PER SQUARE INCH, ABSOLUTE PSIG POUNDS PER SQUARE INCH, GAGE PTS PNEUMATIC TUBE STATION PVC POLYVINYL CHLORIDE RA RETURN AIR RELA RELIEF AIR REQD REQUIRED RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATION SP STATIC PRESSURE SP STAIR PRESSURIZATION AIR (*) SRV SAFETY RELIEF VALVE TA TRANSFER AIR TEMP TEMPERATURE TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UC UNDER CUT (DOOR) UG UNDERGROUND UP UP VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE VIF VERIFY IN FIELD VTR VENT-THRU-ROOF W/ WITH MID WITHOUT WB WET BULB TEMPERATURE WG WATER GAUGE ZN-# ZONE °C CELSIUS OF FAHRENHEIT GENERAL NOTES 1. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND ARE BASED ON ONE MANUFACTURER'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL OF THE DETAILS FOR THE EQUIPMENT. THE MECHANICAL CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT AND ENSURE THAT IT WILL FIT IN THE AVAILABLE SPACE. 2. MECHANICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF COMPLETED AND OPERATIONAL SYSTEMS WITH DUE RESPECT TO ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. 3. IT IS THE CONTRACTOR RESPONSIBILITY TO FIELD VERIFY ALL CONNECTION POINTS PRIOR TO INSTALL. NOT ALL CONNECTION SIZES ARE SHOWN, BUT THOSE THAT ARE APPROXIMATE AND TAKEN FROM EXISTING AS-BUILTS AND FIELD OBSERVATIONS. 4. COORDINATE PIPE ROUTING WITH DUCTWORK, SPRINKLER PIPING AND ELECTRICAL POWER/LIGHTING CIRCUITING AND STRUCTURAL MEMBERS PRIOR TO INSTALLATION. 5. CONTRACTORS TO VERIFY ALL GRADES, DIMENSIONS AND EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK. NOTIFY PRIME CONSULTANT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL CONDITIONS BEFORE INSTALLATION. 6. ALL MATERIALS AND INSTALLATION SHALL COMPLY WITH THE CONSTRUCTION SPECIFICATIONS. 7. COORDINATE INSTALLATION OF PIPING AND DUCTWORK WITH ELECTRICAL CONTRACTOR AND OTHER TRADES. 8. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS NEEDED TO CONSTRUCT WORK SHOULD IN THE CONSTRUCTION DOCUMENTS AND ACCOMPANYING SPECIFICATIONS. 9. IF THERE IS A CONFLICT BETWEEN THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS, THE MOST STRINGENT WILL APPLY. 10. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURERS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS, DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 11. PENETRATIONS OF DUCTS, PIPES, CONDUITS,ETC IN WALLS REQUIRING PROTECTED OPENINGS SHALL BE FIRE STOPPED, FIRE STOP MATERIAL, SHALL BE A UL/ULC-LISTED ASSEMBLY APPROPRIATE FOR FIRE OR SMOKE PENETRATIONS AS APPLICABLE AND AS APPROVED BY THE FIRE MARSHAL. 12. THE MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL FIRE, SMOKE, OR COMBINATION SMOKE/FIRE DAMPERS AND ACCESS PANELS COMMENSURATE WITH THE RATING OF THE WALL IN ALL DUCTWORK THAT PENETRATES FIRE WALLS, FIRE BARRIERS, FIRE PARTITIIONS, SMOKE BARRIERS AND SMOKE PARTITION IN ALL DUCTWORK THAT PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS OTHERWISE SHOWN ON THE DRAWINGS. 13. ALL BRANCH DUCTS SHALL HAVE VOLUME DAMPERS. 14. WHERE FLOW EXCEEDS 150 CFM, THE CONTRACTOR SHALL USE SMOOTH RADIUS ELBOWS OR TURNING VANES. 15. ALL DUCT JOINTS SHALL BE SEALED IN ACCORDANCE WITH SMACNA STANDARDS. 16. ALL DUCT DIMENSIONS ARE NET INSIDE VALUES. DIMENSIONS MAY BE CHANGED PROVIDED THAT THE NET FREE AREA IS MAINTAINED. 17. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1" FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING. 18. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA). 19. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAPS TO SUPPORT PIPES WILL NOT BE PERMITTED. REFER TO SPECIFICATIONS FOR MINUMUM SPACING OF PIPE SUPPORTS. 20. THE HVAC SYSTEMS SHALL BE TESTED AND BALANCED BY AN INDEPENDENT AGENCY, UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER. 21. A BUILDING COMMISSIONING PROCESS AND FUNCTIONAL TESTING OF MECHANICAL SYSTEMS SHALL CARRIED OUT BY A CERTIFIED COMMISSIONING PROFESSIONAL. 22. ALL EQUIPMENT TO BE INSTALLED ON MIN 6" THICK CONCRETE HOUSEKEEPING PADS. 23. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED. 24. MECHANICAL EQUIPMENT, DUCTS AND PIPING ARE TO BE COORDINATED WITH STRUCTURAL JOISTS AND CROSS BRACING. 25. ALL EXPOSED PIPING IN OCCUPIED SPACES SUBJECT TO ARCHITECTURAL APPROVAL PRIOR TO INSTALLATION. DEMO NOTES 1. NOT ALL EXISTING CONDITIONS HAVE BEEN SHOWN. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMO. 2. CONTRACTOR SHALL PROTECT ALL WORK AND EXISTING CONDITIONS ASSOCIATED WITH THIS CONTRACT FROM DAMAGE, COVER ENDS OF PIPING AND DUCTWORK NOT ACTIVELY BEING WORKED ON. IT IS THE CONTRACTOR RESPONSIBILITY TO REPAIR OR REPLACE ANY DAMAGED ITEMS THAT OCCURS DURING THIS CONSTRUCTION PROJECT AT NO COST TO THE OWNER. 3. DEMOLISH ALL REQUIRED EQUIPMENT, DUCTWORK, PIPING, HANGERS, CONTROLS AND ALL ASSOCIATED EXISTING SYSTEMS AS REQUIRED. TO REPLACE EACH SYSTEM, CONTRACTOR SHALL COORDINATE DEMOLITION WITH EXISTING SYSTEMS AND COMPONENTS TO REMAIN PRIOR TO WORK COMMENCING. 4. IT IS THE CONTRACTOR RESPONSIBILITY TO CLEAN UP ALL DEBRIS FROM SITE AT THE END OF EACH WORK DAY AND DISPOSE OFF EITHER IN LAY DOWN RECYCLE BINS PROVIDED BY THE CONTRACTOR OR OFFSITE ALL TOGETHER. 5. ALL DEMOLISHED EQUIPMENT SHALL BE TURNED OVER TO THE OWNER UNLESS DIRECTED OTHERWISE. IF NOT REQUIRED BY OWNER, DISPOSE AS REQUIRED. DRAWING INDEX No. DRAWING NAME M001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS M002 MECHANICAL SPECIFICATIONS M101 LEVEL 1 - HVAC DEMO & NEW PLANS M102 BASEMENT - PLUMBING DEMO & NEW PLANS M103 LEVEL 1 - PLUMBING DEMO & NEW PLANS M501 DETAILS & CONTROLS M601 EQUIPMENT SCHEDULES tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 I stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 GENERAL- .Vr���UfYINIs E,�, DEVELOPMENT LEGEN�S�:� "T ABBREVIATIONS ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: Designer DRAWN BY: Author a _o of LP CV 0 N W 1 2 3 4 5 1 6 7 8 9 SHEET NO NOTE: NOT ALL SYMBOLS, SYSTEMS, AND ABBREVIATIONS MAY BE USED ON THIS PROJECTM001 10 11 Y = 0 J W U In a 75 a M LP v CV O CV 0. - 1 1 2 3 1.1 GENERAL A. PROVIDE A COMPLETE OPERATIONAL MECHANICAL SYSTEM AS DESCRIBED HEREIN, AND IN COMPLETE ACCORD WITH APPLICABLE CODES AND STANDARDS. THE SCOPE OF WORK SHALL INCLUDE, BUT NOT LIMITED TO, THE PROVISION OF ALL LABOR, MATERIALS, TOOLS AND EQUIPMENT REQUIRED FOR THE INSTALLATION, TESTING AND COMMISSIONING OF THE COMPLETE MECHANICAL SYSTEM. B. THE DRAWINGS AND SPECIFICATIONS ARE A GUIDE TO ESTABLISHING QUALITY OF EQUIPMENT, MATERIALS, WORKMANSHIP AND PERFORMANCE. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY TO ONE ANOTHER, BUT IN THE EVENT OF A DISCREPANCY THE MORE STRINGENT SHALL PREVAIL. ANY DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS LEAVING IN DOUBT THE TRUE INTENT OF WORK SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. C. THE TERM "PROVIDE" SHALL MEAN TO SUPPLY AND INSTALL. D. REFERENCES TO "ENGINEER" IN THIS DOCUMENT SHALL MEAN STANTEC CONSULTING LTD./STANTEC CONSULTING INC. E. BEFORE SUBMITTING THEIR BID, THE CONTRACTOR SHALL EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING THE WORK UNDER THIS CONTRACT. THE CONTRACTOR SHALL CONFIRM THAT THE WORK SHOWN AND DESCRIBED HEREIN CAN BE COMPLETED WITHOUT ADDITIONAL CHARGES IMMEDIATELY FOLLOWING THE AWARD OF CONTRACT. F. THE MECHANICAL SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS AS ADOPTED BY AUTHORITIES HAVING JURISDICTION INCLUDING APPLICABLE LOCAL BUILDING CODE/INTERNATIONAL BUILDING CODE, ALL REVISIONS AND AMENDMENTS THERETO, AND ANY OTHER CODES THAT MAY BE APPLICABLE. THE CONTRACTOR SHALL PAY ALL FEES, OBTAIN ALL PERMITS REQUIRED, AND OBTAIN INSPECTIONS AND APPROVALS REQUIRED FROM THE AUTHORITIES HAVING JURISDICTION. G. PROVIDE A WRITTEN GUARANTEE STATING THAT ALL MATERIALS AND WORKMANSHIP PROVIDED UNDER THIS CONTRACT SHALL BE REMAIN FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE OF THE COMPLETED WORK, AND FURTHER THAT ANY DEFECTS THAT BECOME APPARENT DURING THE GUARANTEE PERIOD WILL BE CORRECTED AT NO ADDITIONAL COST. H. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL HAVE AN ACCEPTABLE APPEARANCE WHEN COMPLETED. ALL WORKMANSHIP SHALL BE IN ACCORDANCE WITH RECOGNIZED TRADE STANDARDS. I. ALL MATERIALS USED SHALL BE NEW AND OF THE BEST QUALITY AVAILABLE. ALL EQUIPMENT AND MATERIALS SHALL CONFORM TO FLAME SPREAD AND SMOKE DEVELOPED RATINGS AS REQUIRED BY THE APPLICABLE LOCAL AND NATIONAL BUILDING CODES. J. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTALLATION DIRECTIONS. K. THE CONTRACTOR SHALL BE FAMILIAR SCOPE OF WORK AND SHALL COOPERATE WITH THE OWNER SO THAT THE WORK WILL NOT CONFLICT WITH DAY-TO- DAY OPERATIONS. ANY CONFLICTS OR DEFAULTS WHICH ARISE DURING THE CONSTRUCTION PERIOD MUST BE RESOLVED IMMEDIATELY. COMPLY WITH ALL OWNER SPECIFIC WORKPLACE REGULATIONS AND REQUIREMENTS. L. MAKE ANY NECESSARY CHANGES NECESSARY TO ACCOMMODATE THE WORK OF OTHER TRADES AND NOTE SUCH CHANGES ON THE RECORD DRAWINGS. M. PROVIDE GENERAL, LIABILITY AND VEHICLE INSURANCE COVERAGE FOR THE DURATION OF THE WORK. PROVIDE INSURANCE CERTIFICATES WHEN REQUESTED. N. WORK AREAS SHALL BE MAINTAINED IN A CLEAN AND SAFE CONDITION TO THE SATISFACTION OF THE OWNER AND ENGINEER. 0. ALL EXISTING ITEMS WHICH NEED TO BE REMOVED, AND WHICH HAVE A REASONABLE SALVAGE VALUE, SUCH AS FANS AND MOTORS, AIR TERMINALS, PLUMBING FIXTURES, AND VALVES, SHALL BE CAREFULLY REMOVED AND HANDED OVER TO THE OWNER. HANDING OVER TO THE OWNER INCLUDES MOVING TO OWNER'S DESIGNATED STORAGE PLACE ON SITE. THESE ITEMS SHALL NOT BECOME THE PROPERTY OF THE CONTRACTOR. THE OWNER HAS FIRST RIGHT TO THE SALVAGED EQUIPMENT. OBTAIN A WRITTEN RECEIPT FROM THE OWNER DETAILING EACH OF THE ITEMS HANDED OVER. P. ALL EXISTING ITEMS NOT REQUIRED BY THE OWNER SHALL BE REMOVED FROM THE SITE. Q. PATCH AND MAKE GOOD EXISTING SURFACES WHERE DISTURBED BY THE WORK, TO "AS GOOD OR BETTER" CONDITION. USE MATERIALS THAT ARE COMPATIBLE WITH THE EXISTING MATERIALS. R. BE RESPONSIBLE FOR ALL WORK IDENTIFIED OR IMPLIED BY THE DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO: 1. INSTALLATION AND COMMISSIONING OF ALL SYSTEMS, INCLUDING THE EQUIPMENT PROVIDED BY THE OWNER WHERE NOTED. 2. BALANCING THE AIR AND WATER SYSTEMS. 3. MAKE PROVISIONS FOR EASY ACCESS FOR AIR AND WATER BALANCER. 4. REVISION AND TESTING OF THE HEATING, VENTILATION, PLUMBING AND SPRINKLER AND CONTROLS SYSTEM IN THE AREA. 5. DISPOSAL OF ALL UNUSED MATERIAL. 6. BE RESPONSIBLE FOR THE PERFORMANCE AND COMMISSIONING OF ALL EQUIPMENT SUPPLIED AND INSTALLED FOR THE PROJECT (INCLUDING ALL EQUIPMENT SUPPLIED BY THE OWNER WHERE APPLICABLE). 1.2 DESCRIPTION OF WORK A. BE RESPONSIBLE FOR ALL WORK IDENTIFIED OR IMPLIED BY THE DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO; 1. INSTALLATION AND COMMISSIONING OF ALL SYSTEMS, INCLUDING THE EQUIPMENT PROVIDED BY THE OWNER WHERE NOTED. 2. BALANCING OF THE AIR AND WATER SYSTEMS. MAKE PROVISIONS FOR EASY ACCESS FOR AIR AND WATER BALANCER. 3. REVISION AND TESTING OF THE HEATING, VENTILATION, PLUMBING AND SPRINKLER SYSTEMS IN THE AREA. 4. DISPOSAL OF ALL UNUSED MATERIAL. 5. BE RESPONSIBLE FOR THE PERFORMANCE AND COMMISSIONING OF ALL EQUIPMENT SUPPLIED AND INSTALLED FOR THE PROJECT (INCLUDING ALL EQUIPMENT SUPPLIED BY THE OWNER WHERE APPLICABLE) 1.3 STANDARD OF ACCEPTANCE A. MEANS THAT ITEM NAMED AND SPECIFIED BY MANUFACTURER AND/OR EQUIPMENT MODEL NUMBER CONFORMS TO SPECIFICATIONS AND SETS STANDARD REGARDING PERFORMANCE, QUALITY OF MATERIAL AND WORKMANSHIP AND WHEN USED IN CONJUNCTION WITH A REFERENCED STANDARD, SHALL BE CONSIDERED TO SATISFY THE STANDARD. B. WHERE TWO OR MORE MANUFACTURERS ARE LISTED, THE MANUFACTURER'S NAME SHOWN UNDERLINED OR SHOWN WITH A MODEL NAME AND/OR NUMBER, WAS USED IN PREPARING THE DESIGN. PROJECT BIDS MAY BE BASED ON ANY ONE OF THOSE NAMED, PROVIDED THAT THEY MEET EVERY ASPECT OF THE DRAWINGS AND SPECIFICATIONS. C. WHERE OTHER THAN THE UNDERLINED MANUFACTURER OR NAMED MANUFACTURER IS SELECTED OR APPROVED, CONTRACTOR SHALL COVER THE COST OF ANY RESULTING WORK (BOTH UNDER THIS DIVISION AND OTHER DIVISIONS) AND ANY NECESSARY REDESIGN OF INSTALLATION OR STRUCTURE. SUBMIT REDESIGN DRAWINGS FOR REVIEW WITH SHOP DRAWINGS. MAINTAIN INSTALLATION, ACCESS AND SERVICING CLEARANCES. REDESIGN DRAWINGS SHALL BE TO SCALE AND OF A STANDARD EQUAL TO THE PROJECT DRAWINGS. D. WHERE TWO OR MORE ITEMS OF EQUIPMENT AND/OR MATERIAL, OF THE SAME TYPE, ARE REQUIRED, PROVIDE PRODUCTS OF A SINGLE MANUFACTURER. E. A VISIBLE MANUFACTURER'S NAMEPLATE SHALL INDICATE MANUFACTURER'S NAME, MODEL NUMBER, SERIAL NUMBER, CAPACITY DATA, ELECTRICAL CHARACTERISTICS AND APPROVAL STAMPS. 1.4 ADDITION OF ACCEPTABLE MANUFACTURERS A. MATERIAL/PRODUCTS CONSIDERED TO SATISFY THE SPECIFICATION, BUT OF A MANUFACTURER OTHER THAN THOSE NAMED IN THE SPECIFICATION MAY BE SUBMITTED TO THE ENGINEER FOR CONSIDERATION NOT LATER THAN FIVE (5) WORKING DAYS PRIOR TO PROJECT BID DATE. B. ADDITION OF MANUFACTURER'S NAMES TO THE SPECIFICATIONS WILL BE IN WRITING BY THE ENGINEER. 1.5 EXISTING SERVICES A. CONFIRM LOCATIONS AND ROUTINGS OF ALL EXISTING SERVICES WHICH MIGHT BE AFFECTED BY THE WORK. PROTECT EXISTING AND REPAIR ANY DAMAGE CAUSED BY ANY WORK PERFORMED. ACCOMMODATE WORK CHANGES IN LOCATION AND ROUTING AS MAY BE NECESSARY. 1.6 CUTTING & PATCHING A. BE RESPONSIBLE FOR ALL CUTTING, PATCHING, DIGGING, AND CORING REQUIRED TO ACCOMMODATE THE MECHANICAL SERVICES. CORRECT AND REPAIR TO MATCH THE ORIGINAL CONDITION. B. VERIFY THE LOCATION OF EXISTING BUILDING SERVICES AND STRUCTURAL REINFORCEMENT WITHIN EXISTING ROOF, FLOORS AND WALLS PRIOR TO CUTTING. CUTTING OF STRUCTURAL BUILDING COMPONENTS SHALL ONLY TAKE PLACE UPON THE RECEIPT OF SPECIFIC WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. REPAIRS TO EXISTING SERVICES DAMAGED AS A RESULT OF CUTTING IS INCLUDED IN THIS SECTION OF THE WORK. 1.7 MISCELLANEOUS METAL A. INCLUDE ALL MISCELLANEOUS STEEL WORK AS OUTLINED IN THE SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO SUPPORT OF EQUIPMENT. B. ALL STEEL WORK SHALL BE PRIME COATED, READY FOR PAINT FINISH. 1.8 ACCESSIBILITY A. INSTALL ALL WORK SO AS TO BE READILY ACCESSIBLE FOR ADJUSTMENT, INSPECTION, OPERATION AND MAINTENANCE. 1.9 ARCHITECTURAL ACCESS DOORS A. INSTALL AT ALL CONCEALED DAMPERS, TRAPS, UNIONS, VALVES, WATER HAMMER ARRESTORS, SPECIAL EQUIPMENT, AND TRAP PRIMERS. B. LOCATE ACCESS DOORS SO THAT ALL CONCEALED ITEMS ARE READILY ACCESSIBLE FOR ADJUSTMENT, OPERATION AND MAINTENANCE. C. DO NOT LOCATE ACCESS DOORS IN FEATURE WALL OR CEILING CONSTRUCTION WITHOUT THE PRIOR APPROVAL OF THE ENGINEER. LOCATE IN SERVICE AREAS WHEREVER POSSIBLE. 1.10 GUARDS AND COVERS A. PROVIDE REMOVABLE PROTECTIVE GUARDS ON ALL EXPOSED V-BELT DRIVES AND SHAFT COUPLINGS IN ACCORDANCE WITH LOCAL SAFETY REGULATION AND OSHA REQUIREMENTS. B. REMOVABLE ACCESS COVERS SHALL BE PROVIDED FOR ALL EQUIPMENT INSTALLED UNDER THIS PROJECT. 1.11 LUBRICATION OF EQUIPMENT A. LUBRICATE ALL EQUIPMENT PRIOR TO BEING OPERATED, EXCEPT SEALED BEARINGS, WHICH SHALL BE CHECKED. B. USE THE LUBRICANT RECOMMENDED BY THE MANUFACTURER FOR THE SERVICE FOR WHICH THE EQUIPMENT IS SPECIFIED. 1.12 ESCUTCHEONS A. PROVIDE ESCUTCHEONS ON ALL PIPES PASSING THROUGH FINISHED WALLS, FLOORS AND CEILINGS. B. ESCUTCHEONS SHALL BE CHROME PLATED OR STAINLESS STEEL SUITABLE FOR DIMENSIONS OF PIPING AND INSULATION. 1.13 PENETRATION OF FIRE SEPARATIONS A. SEAL ALL PIPE AND DUCT PENETRATIONS THROUGH FIRE SEPARATIONS WITH "3M FIRE BARRIER" SYSTEM OR EQUAL U.L. LISTED SYSTEM. COORDINATE WITH OWNER ON PREFERRED SYSTEM. 1.14 PENETRATION OF SOUND AND PRESSURE SEPARATIONS A. SEAL ALL PIPE AND DUCT PENETRATIONS THROUGH SOUND AND/OR PRESSURE SEPARATIONS TO MINIMIZE NOISE TRANSFER AND/OR AIR LEAKAGE. 1.15 TEMPORARY USE OF MECHANICAL SYSTEMS A. OBTAIN WRITTEN PERMISSION FROM THE ENGINEER OR OWNER IF IT IS DESIRED TO USE THE MECHANICAL SYSTEMS FOR TEMPORARY HEAT. B. THE FOLLOWING CONDITIONS MUST BE CONFIRMED PRIOR TO THE USE OF THE MECHANICAL SYSTEMS FOR TEMPORARY HEATING: 1. ANY EQUIPMENT START-UPS SHALL COMPLY WITH SPECIFIED PROCEDURES. 2. ALL SANDING MUST BE COMPLETE, SPRAY PAINTING MUST BE COMPLETE. 3. THE CONTRACTOR MUST PAY FOR THE GAS/ELECTRICITY. 4. ALL INSPECTORS APPROVALS MUST BE RECEIVED. 5. LUBRICATE ALL EQUIPMENT OPERATED. 6. ALARMS/CONTROLS MUST BE OPERATIONAL. C. DURING THE TEMPORARY HEATING PERIOD, COMPLY WITH THE FOLLOWING CONDITIONS: 1. KEEP ALL WORK AREAS CLEAN. 2. MAINTAIN CHEMICAL TREATMENT OF PIPING SYSTEMS. 3. MAINTAIN THE SYSTEMS. 4. OPERATE THE UNITS UTILIZING 100% OUTSIDE AIR IF POSSIBLE, TO AVOID PULLING BUILDING AIR INTO THE RETURN DUCTS AND THE UNITS. D. COVER ALL RETURN AIR OPENINGS WITH FILTER FABRIC TO PREVENT DUST FROM ENTERING DUCT SYSTEMS. E. BEFORE HANDING THE SYSTEMS OVER TO THE OWNER, COMPLY WITH THE FOLLOWING CONDITIONS: 1. BRING PLANT TO" AS -NEW" CONDITIONS. 2. REPLACE ALL PANEL TYPE AIR FILTERS INSTALLED UNDER THIS CONTRACT WITH NEW FILTERS. 3. RE CLEAN DUCTWORK AS NECESSARY AND PROVIDE A REPORT FROM THE APPROVED DUCT CLEANING AGENCY CERTIFYING THAT THE DUCTWORK IS CLEAN. 1.16 SUBSTANTIAL COMPLETION REQUIREMENTS A. BEFORE THE ENGINEER IS REQUESTED TO MAKE AN INSPECTION FOR SUBSTANTIAL COMPLETION OF THE WORK: 1. COMMISSION ALL SYSTEMS AND PROVE OUT ALL COMPONENTS, INTERLOCKS AND SAFETY DEVICES. 2. SUBMIT A LETTER CERTIFYING THAT ALL WORK (INCLUDING CALIBRATION OF INSTRUMENTS AND BALANCING OF SYSTEMS) IS COMPLETE, OPERATIONAL, CLEAN AND ALL REQUIRED SUBMISSIONS HAVE BEEN COMPLETED. B. THE WORK WILL NOT BE CONSIDERED TO BE READY FOR USE OR SUBSTANTIALLY COMPLETION UNTIL THE FOLLOWING REQUIREMENTS HAVE BEEN MET: 1. ALL LIFE SAFETY ITEMS ARE COMPLETED AND FULLY FUNCTIONAL. 2. ALL REPORTED DEFICIENCIES HAVE BEEN CORRECTED. 3. TESTING AND BALANCING COMPLETED. 4. OPERATING AND MAINTENANCE MANUALS COMPLETED. 5. "AS BUILT" RECORD DRAWING READY FOR REVIEW. 6. SYSTEM COMMISSIONING HAS BEEN COMPLETED AND HAS BEEN VERIFIED BY ENGINEER. 7. ALL DEMONSTRATIONS TO THE OWNER HAVE BEEN COMPLETED. 1.17 OPERATING & MAINTENANCE MANUALS A. INSTRUCT THE BUILDING OPERATORS IN THE OPERATION AND PREVENTATIVE MAINTENANCE OF EACH PIECE OF EQUIPMENT AND SYSTEM SUPPLIED AND INSTALLED. COMPLETE AND TURN OVER DOCUMENTATION PRIOR TO SUBSTANTIAL COMPLETION. B. PROVIDE OPERATION AND MAINTENANCE DATA AS REQUIRED UNDER SECTION 01300. C. THE CONTRACTOR SHALL SUPPLY FOUR (4) FINAL AND ONE PRELIMINARY COPY OF THE EQUIPMENT DATA AND MAINTENANCE MANUALS. THE PRELIMINARY COPY REFERRED TO ABOVE SHALL INCLUDE ONLY THE SYSTEMS DESCRIPTIONS, OPERATING AND MAINTENANCE INSTRUCTIONS AND SHALL BE DELIVERED TO THE ENGINEER FOR REVIEW AND COMMENT NO LATER THAN ONE (1) MONTH PRIOR TO THE DATE OF SUBSTANTIAL COMPLETION. THIS COPY MAY BE IN A LOOSE-LEAF RING BINDER. 1 4 5 1 D. PROVIDE THREE (3) COPIES TO OWNER AND ONE (1) COPY TO ENGINEER OF HARD COVER EXTENSION TYPE BINDERS BOUND WITH HEAVY DARK GREEN FABRIC WITH HOT STAMPED GOLD LETTERS ON FRONT AND SPINE INDICATING MECHANICAL OPERATING AND MAINTENANCE MANUALS, ARCH., MECH. ENGINEERING FIRM, CONTRACTOR'S AND PROJECT NAME AT LEAST TEN DAYS PRIOR TO THE SUBSTANTIAL PERFORMANCE INSPECTION DATE. E. PROVIDE A CD-ROM BASED COPY OF THE OPERATING & MAINTENANCE MANUALS DESCRIBED ABOVE. 1. CONSIST OF ALL DATA IN THE MANUALS, ARRANGED IN A "PDF" FORMAT FILE, WITH AN INTERACTIVE MENU SYSTEM OF BOOKMARKS TO MATCH THE MANUAL FORMAT. 2. INCLUDE THE LATEST VERSION OF ADOBE ACROBAT READER. 3. INCLUDE "PDF" FORMAT COPIES OF THE AS -BUILT PROJECT DRAWINGS (CONTACT THE ENGINEER FOR FILES). 4. SUBMIT THE CD-ROM TO THE ENGINEER FOR REVIEW AND COMMENT. INCORPORATE ANY SUGGESTED REVISIONS. F. INDEX THE OPERATING AND MAINTENANCE MANUALS ACCORDING TO THE FOLLOWING INDEX SYSTEM. 1. TAB 1.0 MECHANICAL SYSTEMS: A. PROVIDE TITLE PAGE WITH CLEAR PLASTIC COVER. B. THE FRONT TITLE PAGE SHALL INCLUDE THE COVER INFORMATION IN ADDITION TO: 1. THE OWNER 2. THE ARCHITECT 3. THE ENGINEER 4. THE GENERAL CONTRACTOR 5. THE MECHANICAL CONTRACTOR 6. THE AGENCY PREPARING THE MANUALS 7. THE ADDRESSES, PHONE AND FAX NUMBERS FOR THE ABOVE WILL BE GIVEN ADJACENT TO THEIR NAME. 2. TAB 1.1 LIST OF MECHANICAL DRAWINGS. 3. TAB 1.2 DESCRIPTION OF SYSTEMS: A. PROVIDE COMPLETE DESCRIPTION OF EACH SYSTEM. a. INCLUDE DETAILED SYSTEM DESCRIPTION AND COMPONENTS COMPRISING THAT SYSTEM, EXPLANATION OF HOW EACH COMPONENT INTERFACES WITH OTHERS TO COMPLETE THE SYSTEM, LOCATION OF EACH THERMOSTAT, CONTROLLER, OR OPERATING SETPOINTS. 4. TAB 1.3 OPERATING DIVISION: A. PROVIDE COMPLETE AND DETAILED OPERATION OF EACH MAJOR COMPONENT. 1. INCLUDE STARTING PROCEDURE EXACT SWITCH AND CONTROL LOCATION. 2. DESCRIBE OPERATION OF COMPONENT CONTROLS, CHANGES REQUIRED FOR SUMMER OR WINTER OPERATION AND METHOD OF ACCOMPLISHMENT. 3. DESCRIBE TROUBLE SHOOTING SEQUENCE WHEN SET POINTS CANNOT BE MAINTAINED. 4. DESCRIBE SAFEGUARDS TO CHECK IF EQUIPMENT GOES OFF LINE. 5. TAB 1.4 MAINTENANCE AND LUBRICATION DIVISION: a. PROVIDE DETAILED PREVENTATIVE MAINTENANCE AND LUBRICATION SCHEDULE FOR EACH OF THE MAJOR COMPONENTS INCLUDING DAILY, WEEKLY, MONTHLY, SEMI-ANNUAL AND YEARLY CHECKS AND TASKS. 1. DESCRIBE LUBRICATION AND MAINTENANCE PROCEDURE FOR EQUIPMENT COMPONENTS SUCH AS BEARINGS, DRIVES, MOTORS, AND FILTERS. INCLUDE RECOMMENDED LUBRICANTS. 2. COMPILE THIS INFORMATION FOR EACH TYPICAL PIECE OF EQUIPMENT. 6. TAB 1.5 LIST OF EQUIPMENT SUPPLIERS AND SUB -CONTRACTORS: A. PROVIDE COMPLETE LIST OF EQUIPMENT SUPPLIERS AND SUB -CONTRACTORS, INCLUDING ADDRESS AND TELEPHONE NUMBER. 1. OUTLINE PROCEDURES FOR PURCHASING PARTS AND EQUIPMENT. 2. PROVIDE A PARTS LIST AND REPAIR MANUAL FOR EACH PIECE OF COMPLETE EQUIPMENT SPECIFIED. 7. CERTIFICATION (TAB 2.0, 2.1, ETC.) INCLUDE COPIES OF: A. PRE -OPERATIONAL CLEANING REPORTS AND CHEMICAL TREATMENT AS SPECIFIED IN THE PIPE TESTING AND CLEANING SECTION OF THIS SPECIFICATION. 1. HYDROSTATIC AND AIR TESTS PERFORMED ON PIPING SYSTEMS. 2. EQUIPMENT ALIGNMENT CERTIFICATES. 3. BALANCING REPORTS FOR AIR AND WATER SYSTEMS. 4. VALVE TAG IDENTIFICATION. SCHEDULE INCLUDING LOCATION, SERVICE AND NORMAL POSITION. 5. PIPE COLOR CODE. 6. INSPECTION APPROVAL CERTIFICATES FOR PLUMBING AND GAS SYSTEMS. 7. INSPECTION APPROVAL CERTIFICATES FOR ALL AIR-CONDITIONING HEATING AND VENTILATION SYSTEMS. 8. GUARANTEE CERTIFICATE. 8. SHOP DRAWINGS (TAB 3.0, 3.1, ETC.): a. INCLUDE COPY OF ALL APPROVED ONLY SHOP DRAWINGS. 1. INCLUDE REDUCED RECORD CONTROL DRAWINGS (8'/z" X 11" OR 11" X 17" FOLD OUT). G. THE DIVIDER TABS SHALL BE LAMINATED MYLAR PLASTIC, AND COLORED ACCORDING TO SECTION. THE COLORING IS AS FOLLOWS: MECHANICAL SYSTEMS - 1.0 - 1.5 - ORANGE, CERTIFICATION 2.0 - 2.4 - GREEN, SHOP DRAWINGS AND MAINTENANCE 3.0 - 3.17 - YELLOW. PLASTIC TABS WITH TYPED INSERTIONS WILL NOT BE ACCEPTED. H. PROVIDE A MINIMUM OF THREE (3) MONTHLY, ONE DAY VISITS TO THE BUILDING TO CHECK THAT BUILDING OPERATORS ARE OPERATING AND MAINTAINING MECHANICAL SYSTEMS IN PROPER MANNER AND KEEPING SCHEDULES UP TO DATE. FORWARD COMPLETE WRITTEN REPORT TO THE ENGINEER AFTER EACH VISIT. 1.18 SYSTEMS BALANCING A. ADJUST DUCT AND TERMINAL BALANCE DAMPERS, ADJUSTABLE AIR TURNING DEVICES AND ADJUST OR CHANGE DRIVE SHEAVES TO BALANCE SUPPLY, RETURN AND EXHAUST AIR SYSTEMS TO PROVIDE THE DESIGN AIR QUANTITIES (WITHIN +/-5%) AT EACH OUTLET AND INLET AND TO MAINTAIN THE DESIGN RELATIONSHIP BETWEEN THE SUPPLY AND EXHAUST AIR SYSTEM QUANTITIES. REFER TO THE DRAWINGS FOR AIR QUANTITIES. 1. ACCEPTABLE BALANCING CONTRACTORS: [PROJECT SPECIFIC REQUIREMENTS]. 2. ADJUST ALL AIR TERMINALS TO OBTAIN THE OPTIMUM AIR DISTRIBUTION PATTERN. 3. ADJUST ALL AIR FLOW AND PRESSURE SENSING DEVICES. 4. ADJUST THE NEW WATER SYSTEMS TO DESIGN FLOW CONDITIONS. 5. ADJUST THE DOMESTIC HOT WATER RECIRCULATION SYSTEM FLOW RATES. 6. INCLUDE THREE (3) COPIES OF A BALANCE REPORT FOR INCLUSION INTO THE MANUALS. 1.19 SUBMITTALS A. THE CONTRACTOR SHALL PROVIDE A SINGLE PDF COPY OF SUBMITTALS OF ALL EQUIPMENT AND MATERIAL FOR THE ENGINEER'S REVIEW. SUBMIT CLEAR AND DESCRIPTIVE CONTROL SEQUENCES PRIOR TO INSTALLATION. 1.20 AS -INSTALLED RECORD DRAWINGS A. MAINTAIN ONE SET OF RECORD DRAWINGS AT THE SITE. CLEARLY MARK IN RED ANY CHANGES OR DEVIATIONS FROM THE ORIGINAL DESIGN INTENT. RECORD ALL CHANGES TO THE WORK AS THE INSTALLATION PROGRESSES. B. AT THE COMPLETION OF THE WORK, CERTIFY THE DRAWING AS BEING ACCURATE, UPDATE THE IFC DRAWINGS TO REFLECT THE CHANGES, AND MARK THE DRAWING AS "AS -BUILT", AND SEND TO THE ENGINEER UPON SUBSTANTIAL COMPLETION OF THIS CONTRACT. 1.21 IDENTIFICATION A. EACH PIPING SYSTEM SHALL BE COLOR CODED FOR IDENTIFICATION AND LABELED WITH THE SYSTEM IDENTIFICATION CODE LETTERS, INCLUDING TEMPERATURE AND PRESSURE, IF APPLICABLE, AND DIRECTIONAL FLOW ARROWS. 1. IDENTIFY ALL NEW PIPING TO EXISTING BUILDING IDENTIFICATION STANDARDS. 2. IDENTIFY PIPING ADJACENT TO VALVES AND WHERE VALVES ARE IN SERIES AT NO MORE THAN 10 FOOT INTERVALS. IDENTIFY PIPING AT LEAST ONCE IN EACH ROOM AND AT 50 FOOT MAXIMUM SPACING IN OPEN AREAS. EXCEPTION: GAS PIPING TO BE IDENTIFIED AT 10 FOOT INTERVALS IN CEILING PLENUMS. 3. IDENTIFY PIPING BOTH SIDES WHERE PIPING PASSES THROUGH WALLS, PARTITIONS AND FLOORS. IDENTIFY PIPING AT POINT OF ENTRY AND LEAVING EACH PIPE CHASE AND/OR CONFINED SPACE. IDENTIFY PIPING ACCESSIBLE AT EACH ACCESS OPENING. 4. IDENTIFICATION LABELS MAY BE STENCILED. IDENTIFICATION ARROWS LABELS AND LETTERS MAY BE VINYL CLOTH (BRADY B500) OR VINYL FILM (BRADY B946), WITH ADHESIVE COMPATIBLE WITH THE SURFACE TEMPERATURE. 5. IDENTIFICATION COLOR BANDS FOR PRIMARY AND SECONDARY COLORS TO INDICATE THE TYPE AND DEGREE OF HAZARD SHALL BE APPLIED TO OVERLAP A MINIMUM OF 2". BANDS SHALL BE BRADY B550 VINYL CLOTH TAPE OR BRADY B946 VINYL TAPE, WITH ADHESIVE COMPATIBLE WITH THE SURFACE TEMPERATURE. 6. COMPLY WITH ASME A13.1 COLOR STANDARDS UNLESS NOTED OTHERWISE. B. EACH PIECE OF EQUIPMENT SHALL BE IDENTIFIED WITH ITS EQUIPMENT SCHEDULE IDENTIFICATION, E.G. SUPPLY FAN SF-1, COOLING COIL CC-1, PUMP P-1. 1. PROVIDE LAMINATED PLASTIC PLATES WITH BLACK FACE AND WHITE CENTER OF MINIMUM SIZE 3'/2" X 1'/2" X 3/32" ENGRAVED WITH HIGH LETTERING. USE 1" HIGH LETTERING FOR MAJOR EQUIPMENT. 2. APPLY NAMEPLATES SECURELY IN CONSPICUOUS PLACES, ON COOL SURFACES. C. SECURE'/4" SELF-ADHESIVE COLORED DOTS TO THE CEILING, TO IDENTIFY THE LOCATION OF ACCESS TO EQUIPMENT CONCEALED ABOVE THE CEILING. 1.22 VIBRATION ISOLATION A. PROVIDE VIBRATION ISOLATION ON ALL MOTOR DRIVEN EQUIPMENT WITH MOTORS OF'/z HP AND GREATER POWER OUTPUT (AS INDICATED ON THE MOTOR NAMEPLATE) AND ON PIPING AND DUCTWORK, AS SPECIFIED HEREIN. FOR EQUIPMENT LESS THAN ''/z HP, PROVIDE NEOPRENE GROMMETS AT THE SUPPORT POINTS. B. PROVIDE %" THICK CONTINUOUS PERIMETER CLOSED CELL FOAM GASKET TO ISOLATE BASE OF PACKAGE TYPE EQUIPMENT, AHU'S, EXHAUST FANS, ETC. FROM FLOORS, ROOFS AND ROOF CURBS. SELECT WIDTH FOR NOMINAL 3 PSIG LOADING UNDER WEIGHT OF EQUIPMENT AND ALLOW FOR 25% COMPRESSION, 3/16". INCREASE WIDTH OF CURB USING STEEL SHIM IF NECESSARY TO ACCOMMODATE GASKET. FOR LIGHT EQUIPMENT SUCH AS EXHAUST FANS, DEFLECTION SHOULD BE A MINIMUM OF 0.05". USE HOLD DOWN BOLTS SELECTED FOR SEISMIC LOADS. ISOLATE BOLTS FROM BASE OF UNIT USING NEOPRENE HEMI-GROMMETS. AVOID COMPRESSING GASKET (E.G. USE HILTI HVA ADHESIVE SET BOLTS, OR EQUAL, WITH STEEL WASHERS AND LOCK NUTS, ADJUSTED FINGER TIGHT TO THE HEMI-GROMMETS). SIZE BOLT AND HEMI-GROMMET FOR MINIMUM LATERAL CLEARANCE. STANDARD OF ACCEPTANCE: AMERICAN NATIONAL RUBBER-EPDM-SBR BLEND SCE 41 TYPE SELF -EXTINGUISHING NEOPRENE, MASON INDUSTRIES TYPE HG HEMI-GROMMETS 1.23 SEISMIC RESTRAINTS A. PROVIDE ANCHORAGE AND BRACING ON ALL ISOLATED EQUIPMENT AND SEISMIC RESTRAINT ON ALL OTHER EQUIPMENT, PIPING AND DUCTWORK, ALL IN ACCORDANCE WITH THE LATEST EDITION OF APPLICABLE LOCAL BUILDING CODE, ASCE 7, AND SMACNA GUIDELINES. B. INCLUDE IN THE BID SERVICES OF AN APPLICABLE APPROPRIATE PROFESSIONAL ENGINEER, REGULARLY EMPLOYED IN THE DESIGN OF SEISMIC RESTRAINT SYSTEMS TO REVIEW AND SIGN -OFF ON ALL SEISMIC SUPPORTS AND RESTRAINTS. SUBMIT "SEALED AND SIGNED" LETTERS OF ASSURANCE FROM THE SEISMIC ENGINEER. C. IT IS THE ENTIRE RESPONSIBILITY OF EQUIPMENT MANUFACTURERS TO DESIGN THEIR EQUIPMENT SO THAT THE STRENGTH AND ANCHORAGE OF INTERNAL COMPONENTS OF THE EQUIPMENT EXCEEDS THE FORCE LEVEL USED TO RESTRAIN AND ANCHOR THE UNIT ITSELF TO THE SUPPORTING STRUCTURE. D. ALL RESILIENTLY MOUNTED EQUIPMENT, INCLUDING PIPING AND DUCTWORK, SHALL BE PROVIDED WITH SEISMIC RESTRAINING DEVICES (SNUBBERS). E. AIR TERMINALS INSTALLED IN GRID CEILINGS ON FLEXIBLE DUCT SHALL HAVE AT LEAST TWO GALVANIZED STEEL SEISMIC RESTRAINT WIRES ATTACHED TO THE BUILDING STRUCTURE OR TO CEILING HANGER WIRES. ATTACH SECURITY BRIDLES AT OPPOSITE CORNERS OF EACH AIR TERMINAL AND IN SUCH A MANNER THAT THE AIR TERMINAL CANNOT FALL. F. PROVIDE FLEXIBLE PIPING CONNECTIONS WITHIN THE HYDRONIC HOT WATER PIPING THAT SERVE TERMINAL UNITS. G. AIR TERMINALS INSTALLED IN GRID CEILINGS ON RIGID DUCT SHALL HAVE AT LEAST TWO SCREWS SECURING THE AIR TERMINAL TO THE DUCT, PER ASCE 7 H. AIR TERMINALS INSTALLED IN GRID CEILINGS NOT ATTACHED TO DUCTS SHALL HAVE AT LEAST TWO SCREWS SECURING THE AIR TERMINAL TO THE CEILING SUPPORT OR AT LEAST TWO GALVANIZED STEEL SEISMIC RESTRAINT WIRES ATTACHED TO THE BUILDING STRUCTURE OR TO CEILING HANGER WIRES. I. PROVIDE GALVANIZED STEEL SEISMIC RESTRAINT WIRES FOR RADIANT CEILING PANELS ATTACHED TO EITHER BUILDING STRUCTURE OR TO CEILING HANGER WIRES. J. ROOF TOP UNIT SYSTEMS SHALL HAVE ROOF CURB/SUPPORT BOLTING RESTRAINT SYSTEMS DESIGNED BY AN APPLICABLE LOCAL PROFESSIONAL ENGINEER, REGULARLY EMPLOYED IN THE DESIGN OF RESTRAINT SYSTEMS. SUBMIT "SEALED" SHOP DRAWINGS FOR REVIEW BY THE ENGINEER. K. SLACK CABLE SYSTEMS 1. SLACK CABLE RESTRAINTS AS SUPPLIED BY MASON INDUSTRIES OR EQUAL. 2. RESTRAINT SYSTEMS AS DETAILED IN SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS" AS REVIEWED BY THE "OFFICE OF THE STATE ARCHITECT, STRUCTURAL SAFETY SECTION" FOR CALIFORNIA. IF LESSER RESTRAINT THAN RECOMMENDED BY SMACNA IS PROPOSED TO MEET LOCAL SEISMIC REQUIREMENTS, PROVIDE SHOP DRAWINGS OF DETAILS CERTIFIED BY AN APPLICABLE LOCAL REGISTERED STRUCTURAL ENGINEER. L. PROVIDE SUBMITTAL TO PROJECT MECHANICAL AND STRUCTURAL ENGINEERS. 1.24 DUCTWORK AND ACCESSORIES A. GALVANIZED STEEL, LOCK FORMING QUALITY. ALL DUCTWORK TO BE CONSTRUCTED, BRACED, CONNECTED AND JOINTED ACCORDING TO ASHRAE AND SMACNA. B. SNAPLOCK SEAMS AND CRIMP JOINTS ARE NOT ACCEPTABLE. C. ALL DUCT JOINTS, INDOOR AND OUTDOOR, SHALL BE COMPLETELY SEALED TO A CLASS A SEAL WITH AN APPROVED SEALANT, REGARDLESS OF PRESSURE CLASS. SEALANTS SHALL MEET ACCEPTABLE SMOKE AND FLAME SPREAD RATINGS. D. DUCT PRESSURE CLASSES: 1. HIGH PRESSURE SUPPLY DUCTWORK: A. DUCTWORK BETWEEN AHU AND TERMINAL UNIT; CONSTRUCT TO 4" W.C. 2. LOW PRESSURE SUPPLY DUCTWORK: A. DUCTWORK BETWEEN TERMINAL UNIT AND DIFFUSERS/GRILLE; CONSTRUCT TO 2" W.C. 3. RETURN/EXHAUST DUCTWORK: A. DUCTWORK BETWEEN AHU/FAN AND DIFFUSERS/GRILLE; CONSTRUCT TO 3" W.C. E. FLEXIBLE DUCT 1. PROVIDE MAXIMUM OF 48" OF FLEXIBLE CONNECTION FOR FINAL CONNECTIONS TO DIFFUSERS ONLY. DO NOT USE FLEX FOR MORE THAN A 90 DEGREE CHANGE OF DIRECTION. 2. WHERE FLEXIBLE DUCTWORK IS USED, PROVIDE FACTORY FABRICATED INSULATED FLEX, AS FOLLOWS: A. FLEXIBLE VINYL COATED STEEL HELIX BONDED TO INNER DUCT LINER. FIBROUS GLASS THERMAL INSULATION. B. OUTER JACKET OF METALIZED FIRE-RESISTANT VAPOR BARRIER. C. SUITABLE FOR UP TO 2" W.G. POSITIVE STATIC PRESSURE AND/OR 1" W.G. NEGATIVE STATIC PRESSURE. D. UL OR ULC LABELED, CLASS 1, DUCT CONNECTOR. E. CONNECT TO DUCTWORK USING TWO WRAPS OF DUCT TAPE AND STAINLESS STEEL WORM DRIVE CLAMPS OR PANDUIT ADJUSTABLE DIAMETER CLAMPS OR THERMAFLEX DUCT STRAP. F. PROVIDE BACKDRAFT DAMPERS WHERE INDICATED ON THE DRAWINGS. 1. MINIMUM REQUIREMENTS: A. 16 GAUGE GALVANIZED STEEL OR ALUMINUM CHANNEL FRAME. B. 16 GAUGE ALUMINUM BLADES, COMPLETE WITH STIFFENING RIBS/BENDS. C. FULL BLADE LENGTH SHAFTS; BRASS, BALL OR NYLON BEARINGS. D. FELT OR NEOPRENE ANTI -CHATTER BLADE STRIPS. E. BLADE CONNECTING LINKAGE WITH EYELET AND PIN BEARINGS. F. MAXIMUM BLADE LENGTH OF 30" USE MULTIPLES FOR LARGER DIMENSIONS. G. MANUFACTURER'S LABEL. H. WHERE A BALANCED BACKDRAFT DAMPER (BBD) IS INDICATED THE DAMPER SHALL INCORPORATE AN ADJUSTABLE COUNTERBALANCE WEIGHT AND LEVER. 6 7 1 8 I. MAXIMUM PRESSURE DROP ACROSS DAMPER AT 800 FPM SHALL BE 0.20" W.G. J. SHALL WITHSTAND UP TO 10 IN WG. OF STATIC PRESSURE. K. STANDARD OF ACCEPTANCE: RUSKIN, GREENHECK, AIR CONTROL PRODUCTS G. PROVIDE BALANCE DAMPERS WITH LOCKING QUADRANT ON EACH RUN OUT TO A GRILLE OR DIFFUSER AND WHERE INDICATED ON THE DRAWINGS. 1. IDENTIFY THE AIRFLOW DIRECTION AND BLADE ROTATION AND OPEN AND CLOSED POSITION. 2. PROVIDE SHEET METAL BRIDGE TO RAISE QUADRANT TYPE OPERATORS ABOVE THE INSULATION THICKNESS. PROVIDE OPEN END BEARINGS WHERE BRIDGES ARE USED. 3. THE DAMPER OPERATING LEVER SHALL BE ARRANGED PARALLEL WITH THE DAMPER BLADE. H. WIRE MESH SCREENS 1. PROVIDE WIRE MESH SCREENS IN ALL AIR INTAKE OPENINGS WHERE NOTED ON THE DRAWINGS. 2. SCREENS SHALL BE CONSTRUCTED FROM ALUMINUM WIRE 16 GAUGE DIAMETER. 3. SCREEN MESH SHALL BE'/z'. I. PROVIDE FIRE DAMPERS WHERE INDICATED ON THE DRAWINGS. 1. FIRE DAMPERS SHALL BE UL TESTED AND LABELED. FIRE DAMPERS SHALL BE CURTAIN TYPE, FUSIBLE LINK ACTUATED, WEIGHTED TO CLOSE AND LOCK IN CLOSED POSITION WHEN RELEASED OR HAVING NEGATOR-SPRING-CLOSING OPERATOR FOR MULTI -LEAF TYPE IN HORIZONTAL POSITION WITH VERTICAL AIR FLOW. CURTAIN FIRE DAMPERS SHALL HAVE BLADES RETAINED IN A RECESS SO FREE AREA OF CONNECTING DUCTWORK IS NOT REDUCED. STANDARD OF ACCEPTANCE: RUSKIN, NAILOR HART, CONTROLLED AIR. 2. INSTALL IN ACCORDANCE WITH THE SMACNA FIRE, SMOKE AND RADIATION DAMPER INSTALLATION GUIDE FOR HVAC SYSTEMS - LATEST EDITION. 3. SIZE SO THAT THE FREE AREA OF THE DUCT IS MAINTAINED THROUGH THE ASSEMBLY. 4. INSTALL IN GALVANIZED STEEL SLEEVE, RETAINED IN PLACE WITH RETAINING ANGLES ON ALL FOUR SIDES AT EACH FACE OF WALL. 5. CONNECT DUCTWORK TO DAMPER SLEEVES USING BREAK -AWAY DUCT JOINTS ON ALL FACES. 6. FIRE DAMPERS MUST BE INSTALLED WITHIN WALL THICKNESS OF FIRE SEPARATION. 7. USE UL APPROVED FIRE STOP SEALANT TO CAULK ALL JOINTS BETWEEN THE FIRE DAMPER SLEEVE ANGLES AND THE SLEEVE AND BETWEEN THE FIRE DAMPER SLEEVE ANGLES AND THE FIRE SEPARATION. 1.25 DUCTWORK CLEANING A. BEFORE HANDING THE SYSTEMS OVER TO THE OWNER, COMPLY WITH THE FOLLOWING CONDITIONS: 1. AS A CONDITION OF ACCEPTANCE ALL NEW AND /OR EXISTING AIR DUCTWORK SYSTEMS SHALL BE CLEAN. THE CONTRACTOR SHALL CONFIRM SYSTEM CLEANLINESS IN WRITING AND SHALL ASSUME RESPONSIBILITY FOR MISINFORMATION AND CORRECTION OF DAMAGE. BEFORE STARTING FAN SYSTEMS, ALL SUPPLY OUTLETS SHALL HAVE CLEAN CHEESECLOTH ATTACHED TO THEM. 2. FINAL SYSTEMS CLEANING SHALL BE PERFORMED BY AN APPROVED CLEANING AGENCY. 3. THE CLEANING SHALL BE TO THE SATISFACTION OF THE ENGINEER AND OWNER. 4. PROVIDE A REPORT FROM THE APPROVED DUCT CLEANING AGENCY CERTIFYING THAT THE DUCTWORK IS CLEAN. 5. PROVIDE NEW FILTERS FOR ALL AIR HANDLERS AFTER CLEANING HAS BEEN COMPLETED. 1.26 PIPING INSTALLATION A. REAM PIPE ENDS. CLEAN SCALE AND DIRT, INSIDE AND OUTSIDE BEFORE AND AFTER ASSEMBLY. B. DURING CONSTRUCTION, PROTECT ALL OPENINGS IN PIPING AND EQUIPMENT, BY CAPPING OR PLUGGING TO PREVENT ENTRY OF DIRT. C. CONNECT TO EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION UNLESS OTHERWISE INDICATED. D. SLOPE SUPPLY PIPING UP (1:480) IN DIRECTION OF FLOW AND DRAIN FROM LOW POINTS. SLOPE RETURN PIPING DOWN (1:480) IN THE DIRECTION OF FL E. USE ECCENTRIC REDUCERS AT PIPE SIZE CHANGE INSTALLED TO PROVIDE POSITIVE DRAINAGE. F. PROVIDE CLEARANCE FOR ACCESS FOR MAINTENANCE OF EQUIPMENT, VALVES AND FITTINGS. G. INSTALL UNIONS OR FLANGES IN CONNECTIONS TO ALL EQUIPMENT AND SPECIALLY COMPONENTS. H. ARRANGE PIPING CONNECTIONS TO ALLOW EASE OF ACCESS AND FOR REMOVAL OF EQUIPMENT. I. ALIGN AND INDEPENDENTLY SUPPORT PIPING CONNECTIONS ADJACENT TO EQUIPMENT TO PREVENT PIPING STRESSES BEING TRANSFERRED. J. INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL UNLESS APPROVED OTHERWISE. K. INSTALL VALVES TO ISOLATE EACH PIECE OF EQUIPMENT, AND AS INDICATED. L. CONSTRUCT PIPING TO ALLOW FOR EXPANSION AND CONTRACTION. 1.27 PIPE TESTING AND CLEANING A. HYDROSTATICALLY TEST ALL PIPES FOR AT LEAST 24 HOURS AT X PSI PRIOR TO INSULATING. B. REPAIR ALL LEAKS AS REQUIRED FOR ZERO LOSS. C. CHEMICALLY CLEAN AND FLUSH ALL NEW HYDRONIC AND STEAM PIPING PRIOR TO RECONNECTION TO EQUIPMENT. D. THOROUGHLY FLUSH ALL NEW DOMESTIC WATER PIPING. E. PROVIDE CHEMICAL TREATMENT TO MATCH EXISTING AS REQUIRED TO REFILL SYSTEM. F. PROVIDE CHEMICAL TREATMENT AND TEST KIT FOR THE HOT WATER HEATING SYSTEM. 1. PROVIDE BYPASS FILTERS AND POT FEEDER ASSEMBLIES. 2. THE CHEMICAL TREATMENT AGENCY SHALL PROVIDE SUPERVISION OF INSTALLATIONS, SET-UP AND ADJUSTMENT AND SHALL SUBMIT A WRITTEN REPORT ON SYSTEM OPERATIONS. 3. THE CHEMICAL TREATMENT AGENCY SHALL INSTRUCT THE MAINTENANCE PERSONNEL BEFORE SUBSTANTIAL PERFORMANCE. WRITTEN INSTRUCTIONS OF THE TREATMENT, DOSAGES, CONTROL CHARTS AND TEST PROCEDURES SHALL BE INCLUDED IN THE MAINTENANCE MANUALS. 1.28 THERMOMETERS AND GAUGES A. SELECT THERMOMETERS AND GAUGES SO THAT THEIR OPERATING RANGE FALLS IN THE MIDDLE HALF OF THE SCALE RANGE. B. THERMOMETERS SHALL BE PIPE MOUNTED STEM TYPE IN COPPER, BRASS OR BRONZE WELL INSTALLED SO AS NOT TO RESTRICT FLOW. THERMOMETERS SHALL BE NON -MERCURY ACTUATED ADJUSTABLE ANGLE TYPE, 9" SCALE LENGTH, WHITE BACKGROUND WITH BLACK LETTERING, WITH BOTH CELSIUS AND FAHRENHEIT SCALES. C. PRESSURE GAUGES SHALL BE 4.5" DIAMETER, PHOSPHOR BRONZE BOURDON TUBE TYPE WITH WHITE BACKGROUND AND BLACK LETTERING. PROVIDE NEEDLE VALVE AHEAD OF EACH GAUGE. PROVIDE KPA AND PSIG SCALES. USE EXTENSIONS WHERE GAUGES ARE INSTALLED THROUGH INSULATION. 1.29 INSULATION - DUCTWORK A. AS APPLICABLE, USE THE LATEST EDITION OF THE LOCAL APPLICABLE BUILDING CODE AS A REFERENCE STANDARD IF SUFFICIENT DETAIL/INFORMATION IS NOT SPECIFIED HEREIN. B. EXTERNAL DUCT INSULATION - INTERIOR USE 1. MATERIAL: COMMERCIAL -GRADE FIBERGLASS THERMAL WITH INTEGRAL VAPOUR BARRIER. 2. TEMPERATURE RANGE: 40 TO 250°F. 3. THERMAL CONDUCTIVITY AT MEAN TEMPERATURE: K £ 0.27, 75°F1 4. ACCEPTABLE MANUFACTURERS: KNAUF FSK DUCT WRAP, MANSON ALLEY -WRAP FSK, OWENS-CORNING FIBERGLAS COMMERCIAL -GRADE ALL -SERVICE DUCT WRAP. 2. INSTALLED R-VALUE: 5.6 HR-FT2-°F/BTU (BASED ON 2" NOMINAL THICKNESS). 3. DENSITY: 0.75 PCF. 4. FACING: FOIL-REINFORCED-KRAFT (FRK) VAPOR -RETARDING. 5. SEAMS: 2" FACING TAB. 6. BASE PRODUCT: OWENS-CORNING FIBERGLAS COMMERCIAL -GRADE ALL -SERVICE DUCT WRAP. C. INSULATION ACCESSORIES 1. ALL INSULATION ACCESSORIES (ADHESIVES, TAPE, COATINGS, ETC.) SHALL BE APPROVED FOR THE SPECIFIC APPLICATION. D. DUCT INSULATION SCHEDULE: 1. PROVIDE 1" THERMAL INSULATION FOR ALL INTERIOR SUPPLY DUCTS. 2. PROVIDE 2" INSULATION ON LINEAR DIFFUSER PLENUMS. 3. PROVIDE 2" INSULATION ON ALL DIFFUSERS. 1.30 INSULATION - PIPING & EQUIPMENT A. AS APPLICABLE, USE THE LATEST EDITION OF THE LOCAL APPLICABLE BUILDING CODE AS A REFERENCE STANDARD IF SUFFICIENT DETAIL/INFORMATION IS NOT SPECIFIED HEREIN. B. APPLY THE FOLLOWING MATERIALS OVER THE ENTIRE LENGTH OF THE SYSTEM INCLUDING VALVES, TANKS AND PIPING EQUIPMENT ETC.: C. COLD PIPING: RIGID FIBROUS GLASS INSULATION WITH VAPOR BARRIER AND FACTORY APPLIED GENERAL PURPOSE JACKETS, / K £ 0.23, 75 DEG F D. HOT PIPING: RIGID FIBROUS GLASS INSULATION WITH FACTORY APPLIED GENERAL PURPOSE JACKET, MOULDED TO CONFORM TO PIPING, K £ 0.23, 75 DEG F E. COLD EQUIPMENT: COMMERCIAL GRADE ELASTOMERIC THERMAL INSULATION, K £ 0.23, 75 DEG F F. INSULATION ACCESSORIES 1. ALL INSULATION ACCESSORIES (ADHESIVES, TAPE, COATINGS, ETC.) SHALL BE APPROVED FOR THE SPECIFIC APPLICATION. 2. INSTALL FLEXIBLE FOAMED ELASTOMERIC OR FLEXIBLE CLOSED CELL PREFORMED PIPING INSULATION. SECURE LONGITUDINAL AND BUTT JOINTS WITH ADHESIVE. INSULATE ALL FITTINGS AND COMPONENTS. TO OBTAIN THE SPECIFIED THICKNESS, APPLY IN LAYERS WITH STAGGERED JOINTS. G. INSULATION TERMINATION POINTS 1. TERMINATE INSULATION 3" BACK FROM ALL UNINSULATED FITTINGS TO PROVIDE WORKING CLEARANCE AND TERMINATE INSULATION AT 90' AND FINISH WITH REINFORCED SCRIM CLOTH AND VAPOR BARRIER MASTIC SYSTEM. COVER ONTO PIPE AND OVER THE INSULATION VAPOR BARRIER. ON CONCEALED HOT SERVICES TERMINATE INSULATION 3" BACK FROM ALL UNINSULATED FITTINGS, CUT OFF AT 90'AND APPLY REINFORCED SCRIM CLOTH AND BREATHER MASTIC SYSTEM. 2. CUT BACK INSULATION AT 450 AND FINISH WITH A SILICONE CAULKING SEALANT AROUND THE BASE OF THERMOMETER WELLS, PRESSURE GAUGES, FLOW SWITCHES AND PRESSURE AND CONTROL SENSORS. H. PIPE INSULATION SCHEDULE: 1. INSULATE MRI QUENCH VENT WITH ONE LAYER OF 1.5" THICK INSULATION. PORTIONS OF PIPING EXPOSED TO AMBIENT SHALL BE WEATHER PROTECTED WITH ALUMINUM JACKETING. 2. PROVIDE 1" INSULATION FOR ALL DOMESTIC HOT WATER AND HOT WATER RECIRCULATION PIPES 2" AND SMALLER. 1'/z" FOR ALL DOMESTIC HOT WATER HOT WATER AND RECIRCULATION PIPES GREATER THAN 2". 3. PROVIDE 1" INSULATION FOR ALL DOMESTIC COLD WATER PIPES. 1.31 DOMESTIC WATER SYSTEMS - PIPING, VALVES AND FITTINGS A. PIPING AND FITTINGS 1. HOT AND COLD WATER AND HOT WATER RECIRCULATION PIPING: TYPE L COPPER, WITH SOLDER JOINTS, AND WROUGHT COPPER OR CAST BRASS FITTINGS AND 95/5 SN/SB, SILVABRITE 100, RIGID GROOVED MECHANICAL WITH ANGLE PATTERN BOLT PAD FOR PIPES 2" AND LARGER, OR OTHER LEAD FREE SOLDER JOINTS. B. BALL VALVES 1. BALL: A. 2" AND SMALLER, BRASS TWO-PIECE BODY, BLOW-OUT PROOF AND EXTENDED STEM, SOLDER PTFE SEATS, BRASS CHROME PLATE BALL, LEVER HANDLE OPERATOR, 150 PSIG RATING. 2. ACCEPTABLE PRODUCTS: A. SOLDER JOINT TYPE: RED & WHITE / TOYO 5049A, APOLLO, CRANE, JENKINS, KITZ, LUNKENHEIMER 746FS OR 747FS, NEUMAN-HATTERSLEY, NIBCO, WATTS, WORCESTER, MILWAUKEE BA-150S (SOLDER). B. THREADED JOINT TYPE: RED & WHITE / TOYO 5044A, APOLLO-70 SERIES, CRANE 93-TF, GRINNELL 3700 FULL PORT, JENKINS-1101-T, KITZ 58, LUNKENHEIMER 746F OR 747F, NEUMAN-HATTERSLEY 1969AT, NIBCO T-580-BR, WATTS B-6000, WORCESTER 4211-RT, MILWAUKEE BA-100S(THREADED). C. CHECK VALVES 1. 2" AND SMALLER: WYE PATTERN, HORIZONTAL SWING, CLASS 150, BRONZE BODY, THREADED CAP, MODEL- NIBCO T-433-Y OR EQUAL 2. 2'/2" AND LARGER: HORIZONTAL SWING, CLASS 150, CAST IRON BODY, BOLTED BONNET, BRONZE TRIM, RENEWABLE BRONZE OR CAST-IRON DISK AND SEAT, FLANGED. MODEL - STOCKHAM G-931 OR EQUAL D. CIRCUIT BALANCING VALVES 1. MAXIMUM PRESSURE 250 PSIG AND MAXIMUM TEMPERATURE 250°F. 2. CALIBRATED BALANCING VALVE WITH MEMORY, POSITIVE SHUT-OFF, INLET AND OUTLET PRESSURE MEASURING CONNECTIONS WITH INTEGRAL SHUT- OFFS AND DRAINS. 3. CALIBRATION CHARTS AND ADJUSTMENT TOOLS TO BE INCLUDED. 4. ACCEPTABLE PRODUCT: BELL AND GOSSETT - CIRCUIT SETTER, E. WATER HAMMER ARRESTERS 1. PROVIDE AT ALL QUICK ACTING VALVE LOCATIONS. 2. ENGINEERED AND CERTIFIED IN ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE STANDARD WH-201. 1.32 DRAIN, WASTE AND VENT SYSTEMS - PIPING AND FITTINGS A. PIPING AND FITTINGS -ABOVE GRADE 1. WASTE AND VENT PIPING 2" AND SMALLER: A. DWV COPPER WITH CAST BRASS FITTINGS AND SOLDER JOINTS. B. CAST IRON HUBLESS PIPE FITTINGS AND ELASTOMERIC SEALING SLEEVES WITH STAINLESS STEEL CLAMPS 2. WASTE AND VENT PIPING 2'/z' AND LARGER: A. CAST IRON HUBLESS PIPE FITTINGS AND ELASTOMERIC SEALING SLEEVES WITH STAINLESS STEEL CLAMPS B. INSTALL CLEANOUTS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY THE LOCAL PLUMBING CODE. 1.33 PLUMBING FIXTURES AND TRIM A. ACCEPTABLE MANUFACTURERS 1. ACCEPTABLE MANUFACTURERS OF PLUMBING FIXTURES: AMERICAN STANDARD, CRANE, KOHLER, TOTO. 2. ACCEPTABLE MANUFACTURERS OF PLUMBING FAUCETS AND TRIM (EXCEPT HANDS -FREE): MOEN COMMERCIAL, SYMMONS, CAMBRIDGE BRASS, TECK, CHICAGO, CRANE, ZURN. 3. ACCEPTABLE MANUFACTURERS OF HANDS -FREE PLUMBING FAUCETS AND FLUSH VALVES: MOEN COMMERCIAL, SLOAN. 4. ACCEPTABLE MANUFACTURERS OF STAINLESS STEEL SINKS: ARISTALINE, KINDRED, ELKAY, STEEL QUEEN, AMI, METCRAFT. 5. ACCEPTABLE MANUFACTURERS OF WATER CLOSET SEATS: OLSONITE, MOLDEX, BEMIS, CENTOCO 6. ACCEPTABLE MANUFACTURERS OF FIXTURE CARRIERS: SMITH, ZURN, WATTS, ENPOCO. 7. ACCEPTABLE MANUFACTURERS OF FLUSH VALVES (EXCEPT HANDS -FREE): MOEN COMMERCIAL, ZURN, TECK, CHICAGO, CRANE, SLOAN. 8. ACCEPTABLE MANUFACTURERS OF MIXING VALVES: POWERS, SYMMONS, LEONARD, LAWLER B. BARRIER -FREE FIXTURES 1. WATER CLOSETS A. INSTALL ALL WATER CLOSETS DESIGNATED FOR HANDICAP USE AT AN ELEVATION ABOVE THE FINISHED FLOOR LEVEL OF 18" TO THE RIM OF THE FIXTURE. 1) INSTALL OFFSET ON BARRIER -FREE WATER CLOSET FLUSH VALVE CONNECTION TO ELIMINATE ANY INTERFERENCE WITH GRAB BAR MOUNTING. 2) INSTALL THE FLUSH VALVE SUCH THAT THE HANDLE IS FACING THE TRANSFER OR NON -GRAB BAR SIDE OF THE WATER CLOSET. 9 1 10 11 2. LAVATORIES AND SINKS A. OFFSET P-TRAPS SHALL BE INSTALLED WITH THE RUN OF THE P-TRAP PARALLEL TO AND CLOSE TO WALL. 1) SUPPLIES ON HANDICAP LAVATORIES SHALL BE OFFSET TO ACCOMMODATE THE OFFSET P-TRAP. 2) P-TRAPS, WASTE ARMS AND WATER SUPPLIES AT ALL BARRIER -FREE ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED WITH A MANUFACTURED INSULATION KIT OR'/z' OF FIBERGLASS INSULATION AND FINISHED WITH A POLYVINYL CHLORIDE JACKET IN A NEAT AND WORKMANLIKE MANNER. 3 ACCEPTABLE MANUFACTURED PRODUCTS: TRUEBRO'HANDI LAV-GUARD' BROCAR PRODUCTS INC. 'TRAP WRAP' SEXAUER'HANDI LAV-GUARD C. SEE PLUMBING FIXTURE SCHEDULE FOR DETAILS. 1.34 GRILLES, REGISTERS AND DIFFUSERS A. ACCEPTABLE MANUFACTURERS 1. PRICE, TUTTLE & BAILEY, TITUS, NAILOR, KRUEGER B. SEE SCHEDULE FOR DETAILS. 1.35 TERMINAL UNITS A. ACCEPTABLE MANUFACTURERS 1. PRICE, TITUS, NAILOR, TRANE B. SEE SCHEDULE FOR DETAILS tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT M E C H �,.r0_ _ Aj[RTMENT . . . �. .. SPECIFICATIONS ISSUANCE No. I Description Date E�. E: I PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: Designer DRAWN BY: Author SHEET NO M002 1 1 2 I 3 4 I 5 6 7 1 8 Y x c� J U a 2 3 4 I 5 6 I 7 4 5 6 7 TOUCH DOWN OFFICE #1 — S1 I S1 8 6 155 65 I I j xo' I I I I S-1 IN J E I I 8"0 Q� 8"0 L� 135 a, 200 5� I rr—� 24"x12" I I_ a� 8"� SA `° ' 4_�, sq E � - 8"0 SA 17 24"x12" G R2-6 — � E J 6"0 SA CV E 24"x12" _ E — VAV-1-5 24"x12" ao 6. — I E 490 —12"0 SA 16"0 SA— — — N Q � g g � VAV 1 7 I L E 3-10 14"x14" SA M:01 /� �I 24"x24" N IL J - 330 � LEVEL 1 FLOOR PLAN - HVAC -DEMO 3/16" = 1'-0" 4 TOUCH DOWN FFICE # 102 N'o �Sq F/ a U' E 24"x24" E 120 150 I II fU L/V Ir%UQ I LJV V I I V CONNECT TO EXISTING 16"0 EXHAUST DUCT ABOVE CEILING IN HALLWAY 103. 8 8 9 10 GENERAL SHEET NOTES 60"x24" WITH BIRD SCREEN ABOVE CEILING I 28"x18"0 SA NORTH 60"x24" WITH BIRD SCREEN ABOVE CEILING 0 SA TO EXISTING VAV-1-4 LM I I ■r OEM _I - Y EXISTING 28"x18"0 SUPPLY AIR .,,-28"x18"0 SA DUCT TO EXTEND AND CONNECT TO NEW 28"x18"0 SUPPLY DUCT ABOVE CEILING. NORTH 1. EXISTING WORK TO REMAIN IS SHOWN IN HALFTONE. NEW WORK IS SHOWN IN FULL TONE. 2. CONTROLS CONTRACTOR TO VERIFY PROPER OPERATION OF EXISTING TERMINAL BOX DAMPERS, ACTUATORS, AND FANS WITHIN THE AREA OF WORK AND SUBMIT TAB REPORT TO CONSULTANT. 3. PRIOR TO ANY DEMOLITION WORK, COORDINATE AND PRE -TAB OF EXISTING SYSTEM AND PROVIDE REPORT FOR REVIEW. AC-2: TOTAL SUPPLY AIR FLOW SUPPLY AIR DUCT STATIC PRESSURE SUPPLY FAN VFD SPEED TOTAL RETURN AIR FLOW RETURN AIR DUCT STATIC PRESSURE SUPPLY FAN VFD SPEED OUTSIDE AIR FLOW REF-2: TOTAL EXHAUST AIR FLOW EXHAUST AIR DUCT STATIC PRESSURE FAN VFD SPEED DUCT STATIC PRESSURE AND CFM OF MAIN DUCT BRANCH DUCTS AT THE EXIT FROM SHAFT, COORDINATE THE LOCATION WITH ENGINEERS. KEYNOTE LEGEND VALUE Fm2 KEYNOTE TEXT REMOVE EXISTING TERMINAL UNIT AND PREPARE FOR REINSTALLATION. RELOCATE EXISTING TERMINAL UNIT. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 LEVEL 1 �YHEVA&: DEVELOPMENT DEMO ID6EFKJ TMENT PLANS ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 :signer Author a LP CV O N W 1 2 3 LEVEL 1 FLOOR PLAN - HVAC - NEW 3/16" = 1'-0" 4 5 6 7 8 3/16" = 1'-0" SHEET NO 0 2 4 8 12 16 6%%% M 1 01 9 10 11 1 2 3 4 5 6 7 8 9 10 11 n n n GENERAL SHEET NOTES .. mi co U_ w 0 gnmr-_-M� a Q co v N O N BASEMENT FLOOR PLAN - PLUMBING - DEMO 3/16" = V-0" BASEMENT FLOOR PLAN - PLUMBING - NEW 1. EXISTING WORK TO REMAIN IS SHOWN IN HALFTONE. NEW WORK IS SHOWN IN FULL TONE. 2. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FIXTURES, FURNITURE, AND EQUIPMENT. 3. COORDINATE REQUIRED SHUT DOWNS WITH FM&O. ALLOW FOR TEMPORARY BYPASS AS REQUIRED TO MAINTAIN EXISTING OPERATIONS. 4. REMOVE ALL FIXTURES PIPING, VALVES, HANGERS, ETC. MADE REDUNDANT BY WORK SHOWN. 5. PATCH AND MAKE GOOD DAMAGED OR MISSING PIPE INSULATION ON EXISTING -TO -REMAIN PIPING WITHIN THE AREA OF WORK. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 BAS E M t14EMONDS DEVELOPMENT PLUMBjM(Z�pM0 & NEW PLANS ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 3/16" = V-0" SHEET NO 0 2 4 8 12 16 6%%% M102 9 10 11 24034 Designer Author 1 K 3 3/16" = V-0" 4 5 6 7 8 2 3 5 95' 6 8 9 10 11 GENERAL SHEET NOTES Y a "I U 20ffKtz� a a 1 2 3 � LEVEL 1 FLOOR PLAN -PLUMBING -DEMO 3/16" = 1'-0" LEVEL 1 FLOOR PLAN -PLUMBING -NEW 3/16" = 1'-0" 4 5 T 6 2" SAN T 7 a.__�.__.._.__. nr= 3/4" DCW 2" V I p I 2" SAN UP 3/4" DHW i lllC- u 2" SAN 3" SAN UP I 3" SAN UP 2" SAN UP i I 2" SAN UP I . I i I 1 1/4" DCW UP/DN 3/4" DHW UP/DN I 3/4" DHWR UP/DN I i 4" SAN UP/DN I i01 I L! I i �I I I ! I L 4" SAN 4" DHW 1 1/4" DCW UP/DN 3/4" DHW UP/DN -3/4" DHWR UP/DN 'V UP/DN I" SAN UP/DN NORTH <'I� 1. EXISTING WORK TO REMAIN IS SHOWN IN HALFTONE. NEW WORK IS SHOWN IN FULL TONE. 2. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FIXTURES, FURNITURE, AND EQUIPMENT. 3. COORDINATE REQUIRED SHUT DOWNS WITH FM&O. ALLOW FOR TEMPORARY BYPASS AS REQUIRED TO MAINTAIN EXISTING OPERATIONS. 4. REMOVE ALL FIXTURES PIPING, VALVES, HANGERS, ETC. MADE REDUNDANT BY WORK SHOWN. 5. PATCH AND MAKE GOOD DAMAGED OR MISSING PIPE INSULATION ON EXISTING -TO -REMAIN PIPING WITHIN THE AREA OF WORK. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET 2" SAN UP 2" SAN DN 2" SAN UP SUITE 100 2 SAN DI —11/2°v � EDMONDS, WA 98026 2" SAN UP SK-1 SK-1 2" SAN UP SK-1 2" SAN DN 1 1/2" V U-1 -I 7\ \� I � I I ==="- t� WO " SK 1 SOILED UTILITY ,-3/4" DHW 6 7 8 NORTH U HW V DCW UP/DN DHW UP/DN DHWR UP/DN N UP/DN kN UP/DN PERMIT/BID SET RECEIVED 11/8/24 LEVEL1 CM-Y OF EDMONDS DEVELOPMENT PLUMBjM(ZT,E^M0 & NEW PLANS ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 3/16" = V-0" SHEET NO 0 2 4 8 12 16 MEL 1 M1 03 9 10 11 24034 .signer Author 1 2 3 4 5 6 7 8 9 1 10 11 Y c� J W U m a DDC POINTS SCHEDULE DESCRIPTION: ACRONYM Al DI AO DO ALARM NOTES FAN POWERED AIR TERMINAL UNITS (VAV-X-X) SPACE TEMPERATURE SENSOR VAV-X-X_TS-4 X YES DISCHARGE TEMPERATURE SENSOR VAV-X-X TS-2 X PRIMARY AIR DAMPER VAV-X-X DMPR X PRIMARY AIR CFM VAV-X-X_PRM_CFM X SUPPLY AIR CFM VAV-X-X_SUP _CFM X ELECTRIC HEAT VAV-X-X HEAT X FACTORY MOUNTED TERMINAL CONTROL UNIT rnni nn�nirnrn ------------------------------ ROOM SENSOR -----------------------------------------------------------J TS WITH PUSH BUTTON -------------------------------------------------------------- 4 OVERRIDE SENSOR �► TO DDC COMMUNICATION LINE SEQUENCE OF OPERATION: A. GENERAL: THE UNIT DAMPER MODULATES TO MAINTAIN ROOM TEMPERATURE SETPOINT (75°F ADJUSTABLE) AS SENSED BY TS/4. FAN RUNS CONTINUOUSLY IN OCCUPIED MODE TO MIX ROOM RETURN AIR AND PRIMARY AIR TO MAINTAIN CONSTANT AIR VOLUME. BETWEEN 70OF AND 750F SPACE TEMPERATURE, THE PRIMARY AIR DAMPER MODULATES FROM MAXIMUM TO MINIMUM CFM AS SCHEDULED. ELECTRIC HEATING COILS ARE NOT ACTIVATED UNTIL SPACE TEMPERATURE AS SENSED BY TS/4 DROPS TO 70°F. ELECTRIC HEAT CONTROL SHALL MODULATE TO MAINTAIN 70OF SPACE TEMP. ABOVE 70°F, ELECTRIC HEAT SHALL BE OFF. B. UNOCCUPIED MODE: THE FAN TERMINAL UNITS CYCLE ON AND OFF WITH THE ELECTRIC HEAT ON TO MAINTAIN A ROOM SET BACK TEMPERATURE OF 60°F. IN THE WARM-UP MODE, THE FAN TERMINAL UNITS OPERATE TO MAINTAIN A SPACE TEMPERATURE OF 70-F. ALL FAN TERMINAL UNITS SHALL OPERATE WITH PRIMARY AIR DAMPER FULLY CLOSED DURING THE WARM-UP MODE, AND ELECTRIC HEAT SHALL BE ACTIVATED TO MAINTAIN 70OF TEMPERATURE. C. OVERRIDE SEQUENCE: OVERRIDE PUSHBUTTON SHALL BRING ON ASSOCIATED TERMINAL UNIT FAN FOR AIR CIRCULATION. OVERRIDE PERIOD SHALL BE ADJUSTABLE FROM 0-4 HOURS 3 FAN POWERED TERMINAL UNIT M501 12" = V-0" 2 M501 BELLMOUTH OR CONICAL PRIMARY AIR TAKEOFF FROM SUPPLY MAIN. IF DUCT HEIGHT DOES NOT ALLOW BELLMOUTH, PROVIDE MITERED RECT TO ROUND TAKEOFF THREADED ROD HANGERS WITH NEOPRENE ISOLATION AND HANGING BRACKETS MEDIUM 1" ACOUSTIC PRESSURE LINING SUPPLY DUCT SERIES FLOW FAN POWERED TERMINAL UNIT INLET DUCT HEATING COIL W/ 24" MAX INSULATION 8" MIN LIGHT FIXTURE ACCESSIBLE CEILING RETURN AIR OPENING. INSTALL BOXES CLEAR PROVIDE TEMPORARY OF LIGHTS AND CEILING DEVICES CONSTRUCTION FILTER FOR FULL ACCESS TO FPTU NOTES: BOTTOM PANELS 1. PROVIDE 1" ACOUSTICAL LINING 10 FEET DOWNSTREAM OF FAN POWERED TERMINAL UNIT. INCLUDE LINED FITTINGS IF LESS THAN 10 FT FROM FPTU 2. PROVIDE MINIMUM 5 FEET DISCHARGE DUCT PRIOR TO FIRST DUCT TAKEOFF 3. PROVIDE NEC REQUIRED CLEARANCE AT ALL CONTROL AND ELECTRICAL PANELS. 4. PROVIDE CONSTRUCTION FILTERS ON THE RETURN AIR OPENINGS FOR ALL FAN POWERED BOX INSTALLATIONS. REMOVE FILTER PRIOR TO BALANCING. 5. INLET DUCT REQUIREMENTS: A. INLET DUCT SAME SIZE AS FPTU INLET IF LESS THAN 15 FT B. FOR STRAIGHT INLET DUCT > 15 FEET, UPSIZE ONE SIZE C. FOR EACH ELBOW IN INLET DUCT, UPSIZE ONE SIZE D. NO FLEXIBLE DUCT ALLOWED E. ELBOWS TO BE 1.5 RADIUS TO DIAMETER MIN F. MINIMUM 3 FEET STRAIGHT DUCT AT FPTU INLET SERIES FAN -POWERED TERMINAL UNIT NOT TO SCALE ROUND DUCT RUNOUT TERMINATE FLEXIBLE DUCT WITH CAULKING AND DRAWBANDS SUPPORT FROM STRUCTURE FLEXIBLE DUCT SUPPORT EVERY 2'-0" AND WHERE THE DUCT CONNECTS TO THE FLEX DUCT. FLEXIBLE DUCT LENGTH SHALL BE 3'-0" +/ 6". FLEX ELBOW. MINIMUM R/D=1 DUCT SUPPORT LCEILING DIFFUSER NOTES: 1. PROVIDE INSULATION TO DIFFUSER NECK ON SUPPLY DIFFUSERS. 2. PROVIDE FLEXIBLE DUCT SUPPORTS AT THE ELBOW TO KEEP SMOOTH THE ELBOW SHAPE. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - ROUND DIFFUSER TERMINATION DETAIL - FLEX ELBOW SUITE 100 NOT TO SCALE 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT DETAIL _RV%S DEPARTMENT CONTROLS ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: Designer DRAWN BY: Author a v N LP v CV O N 1 2 3 4 5 6 7 8 7 10 11 SHEET NO M501 1 1 2 3 1 4 5 1 6 7 1 8 9 1 10 11 Y x 0 U_ W U 20KE�B� a In N LP v CV O N ROOM PRESSURIZATION SCHEDULE AHU SYSTEM VAV ZONE ROOM NUMBER ROOM NAME ROOM AREA (SQFT) CEILING HEIGHT (FT) VOLUME (CU FT) OCC. (# PPL) ASHRAE 170 - 2017 ASHRAE 62.1 - 2019 DESIGN BLDG. PRESS. AIR REL. PRESS. CFM PER SF NOTES AC/HR AIRFLOW CFM (CFM) REQ. PRESS REL. EXH ALL AIR RECIRC. AIR O/A (CFM/PPL) O/A (CFM/SQFT) PEOPLE CFM AREA CFM MIN REQ. O/A CFM EXH (CFM/SQFT) EXH TOTAL AC/HR AIRFLOW CFM (CFM) MIN TOTAL MIN O/A MIN EXH MIN TOTAL MIN O/A MIN EXH S/A O/A EXH S/A O/A R/A EXH AC-2 (E) VAV-1-7 100 WAITING ROOM 437 8.5 3714.5 8 0 0 0 0 0 0 0 0 0 5 0.06 40 26 66 0 0 12.3 4.1 0.0 760 255 760 0 0 1.74 1,2,3,4,5 AC-2 (E) VAV-1-7 101 RECEPTION 160 8.5 1360 3 0 0 0 0 0 0 0 0 0 5 0.06 15 10 25 0 0 7.9 2.6 0.0 180 60 180 0 0 1.13 1,2,3,4,5 AC-2 (E) VAV-1-7 101A WORKROOM 126 8.5 1071 1 0 0 0 0 0 0 0 0 0 5 0.06 5 8 13 0 0 10.1 3.4 0.0 180 60 180 0 0 1.43 1,2,3,4,5 AC-2 (E) VAV-1-6 102 TOUCH DOWN OFFICE #1 82 8.5 697 2 0 0 0 0 0 0 0 0 0 5 0.06 10 5 15 0 0 12.9 4.3 0.0 150 50 150 0 0 1.83 1,2,3,4,5 AC-2 (E) VAV-1-6 103 TOUCH DOWN OFFICE #2 84 8.5 714 2 0 0 0 0 0 0 0 0 0 5 0.06 10 5 15 0 0 12.6 4.2 0.0 150 50 150 0 0 1.79 1,2,3,4,5 AC-2 (E) VAV-1-6 104 EXAM ROOM #1 105 8.5 892.5 3 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 (E) VAV-1-5 105 EXAM ROOM #2 105 8.5 892.5 3 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 (E) VAV-1-5 106 EXAM ROOM #3 108 8.5 918 3 4 2 0 61 31 0 NR NR NR 0 0 0 0 0 0 0 9.2 3.3 0.0 140 50 140 0 0 1.30 1,2,3,4,5 AC-2 (E) VAV-1-5 107 EXAM ROOM #4 106 8.5 901 3 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 9.3 3.3 0.0 140 50 140 0 0 1.32 1,2,3,4,5 AC-2 (E) VAV-1-5 108 SOILED UTILITY 128 8.5 1088 0 10 2 6 181 36 109 NEG YES NO 0 0 0 0 0 0 0 5.5 1.9 11.0 100 35 0 200 -100 NEG 0.78 1,2,3,4,5 AC-2 (E) VAV-1-12 109 MA/RN 277 8.5 2354.5 0 0 0 0 0 0 0 0 0 0 5 0.06 0 17 17 0 0 8.7 2.9 0.0 340 115 340 0 0 1.23 1,2,3,4,5 AC-2 (E) VAV-1-12 /... 110 CORRIDOR "A" 404 8.5 3434 0 0 0 0 0 0 0 0 0 0 0 0.06 0 24 24 0 0 5.2 1.7 0.0 300 100 300 0 0 0.74 1,2,3,4,5 AC-2 (E) VAV-1-12 111 OFFICE 110 8.5 935 1 0 0 0 0 0 0 0 0 0 5 0.06 5 7 12 0 0 6.4 2.2 0.0 100 35 100 0 0 0.91 1,2,3,4,5 AC-2 VAV-1-31 112 EXAM ROOM #5 105 8.5 892.5 2 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 VAV-1-31 113 EXAM ROOM #6 105 8.5 892.5 2 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 VAV-1-31 114 EXAM ROOM #7 110 8.5 935 2 4 2 0 62 31 0 NR NR NR 0 0 0 0 0 0 0 8.3 2.9 0.0 130 45 130 0 0 1.18 1,2,3,4,5 AC-2 VAV-1-32 115 EXAM ROOM #8 110 8.5 935 2 4 2 0 62 31 0 NR NR NR 0 0 0 0 0 0 0 8.3 2.9 0.0 130 45 130 0 0 1.18 1,2,3,4,5 AC-2 VAV-1-32 116 EXAM ROOM #9 105 8.5 892.5 2 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 VAV-1-32 117 EXAM ROOM #10 105 8.5 892.5 2 4 2 0 60 30 0 NR NR NR 0 0 0 0 0 0 0 8.7 3.0 0.0 130 45 130 0 0 1.24 1,2,3,4,5 AC-2 (E) VAV-1-12 118 EXAM ROOM #11 110 8.5 935 2 4 2 0 62 31 0 NR NR NR 0 0 0 0 0 0 0 8.3 2.9 0.0 130 45 130 0 0 1.18 1,2,3,4,5 AC-2 VAV-1-31 119 HALLWAY 162 8.5 1377 0 0 0 0 0 0 0 0 0 0 0 0.06 0 10 10 0 0 6.5 2.2 0.0 150 50 150 0 0 0.93 1,2,3,4,5 AC-2 (E) VAV-1-12 /... 120 CORRIDOR "B" 312 8.5 2652 0 0 0 0 0 0 0 0 0 0 0 0.06 0 19 19 0 0 8.0 2.7 0.0 355 120 355 0 0 1.14 1,2,3,4,5 AC-2 (E) VAV-1-12 121 CLEAN UTILITY 110 8.5 935 0 4 2 0 62 31 0 POS NR NR 0 0 0 0 0 0 0 11.6 3.9 0.0 180 60 80 0 100 POS 1.64 1,2,3,4,5 AC-2 - 122 TOILET #1 60 8 480 0 0 0 0 0 0 0 0 0 0 0 25/50 cfm/unit 0 0 0 0 100 0.0 0.0 12.5 0 0 0 100 -100 NEG 0.00 1,2,3,4,5 AC-2 - 123 TOILET #2 60 8 480 0 0 0 0 0 0 0 0 0 0 0 25/50 cfm/unit 0 0 0 0 100 0.0 0.0 12.5 0 0 0 100 -100 NEG 0.00 1,2,3,4,5 AC-2 VAV-1-32 124 SCHEDULER 89 8.5 756.5 3 0 0 0 0 0 0 0 0 0 5 0.06 15 5 20 0 0 9.5 3.2 0.0 120 40 120 0 0 1.35 1,2,3,4,5 AC-2 VAV-1-32 125 SCHEDULER 89 8.5 756.5 3 0 0 0 0 0 0 0 0 0 5 0.06 15 5 20 0 0 10.3 3.6 0.0 130 45 130 0 0 1.46 1,2,3,4,5 NOTES: 1. OUTSIDE AIR AIR CHANGE RATE IS BASED ON SUPPLY AIR HAVING OA CONCENTRATION OF 33%. 2. REQUIRED AIR CHANGE RATE PROVIDE VIA EXHAUST. 3. "POS" IDENTIFIES SPACE WHERE EXHAUST, RETURN OR BOTH 10% LESS THAN SUPPLY. 4. "NEG" IDENTIFIES SPACE WHERE EXHAUST, RETURN OR BOTH IS 10% MORE THAN SUPPLY. 5. "EX" IDENTIFIES SPACE WHERE AIR IS TO BE EXHAUSTED. FAN POWERED AIR TERMINAL UNIT APPLICATION SCHEDULE UNIT IDENTIFICATION BOX CHARACTERISTICS AIRFLOW ELECTRIC HEAT DUCT RUNOUT BOX TOTAL INTEGRAL MAX MAX MIN VENT CAPACITY SIZE MANUFACTURER MODEL NOTES MARK NUMBER SYSTEM SUITE ROOMS(S) SERVED BOX SIZE INLET BOX APD SOUND COOLING HEATING VALVE EDB (F) LDB (F) KW VOLTS PHASE (IN x IN) NUMBER (CFM) (MBH) (IN) (IN-WG) ATEN (CFM) (CFM) (CFM) VAV 1-5 AC-2 100 105 EXAM #2, 106 EXAM #3, 107 EXAM #4, 108 SOILED UTILITY 2 6 0.15 NO 510 205 205 130 1 13.7 55.0 85.0 4.0 480 3 10 x 12 NAILOR D35SE 1,2,3 VAV 1-6 AC-2 100 102 TOUCHDOWN, 103 TOUCHDOWN, 104 EXAM #1 2 6 0.15 NO 430 90 90 60 5.5 55.0 85.0 1.6 480 3 10 x 12 NAILOR D35SE 1,2,3 VAV 1-7 AC-2 100 100 WAITING ROOM, 101 RECEPTION, 101A WORKROOM 3 10 0.15 NO 1120 250 250 105 16.0 55.0 85.0 4.7 480 3 10 x 12 NAILOR D35SE 1,2,3 VAV 1-12 AC-2 100 109 MA/RN, 110 CORRIDOR "A", 111 OFFICE, 118 EXAM #11, 120 CORRIDOR "B", 121 CLEAN UTILITY 5 14 0.15 NO 1090 190 190 135 18.8 55.0 70.0 5.5 480 3 14 x 12 NAILOR D35SE 1,2,3 VAV 1-31 AC-2 100 110 CORRIDOR "A", 112 EXAM #5, 113 EXAM #6, 114 EXAM #7, 119 HALLWAY 3 8 0.15 NO 640 320 185 125 5.2 55.0 70.0 1.5 480 3 10 x 12 NAILOR D35SE 1,2 VAV 1-32 AC-2 100 115 EXAM #8, 116 EXAM #9, 117 EXAM #10, 120 CORRIDOR "B", 124 SCHEDULER, 125 SCHEDULER 3 8 0.15 NO 715 358 220 150 5.8 55.0 70.0 1.7 480 3 14 x 12 NAILOR D35SE 1,2 NOTES: 1. REFER TO FAN POWERED AIR TERMINAL UNIT SCHEDULE FOR UNIT MAXIMUM SOUND POWER LEVEL PERFORMANCE. 2. BOXES TO BE PROVIDED WITH INTEGRAL ACCESS PANEL. 3. EXISTING FAN POWERED AIR TERMINAL UNIT TO BE REUSED. FAN POWERED AIR TERMINAL UNIT SCHEDULE BOX INFORMATION MAXIMUM DISCHARGE SOUND POWER LEVELS (dB) MAXIMUM RADIATED SOUND POWER LEVELS (dB) DIMENSIONS BOX SIZE BOX INLET (IN) BOX OUTLET (IN x IN) ARRANGE MENT MINIMUM AIRFLOW (CFM) MAXIMUM AIRFLOW (CFM) 125 250 500 1K 2K 4K 125 250 500 1K 2K 4K HEIGHT (IN) LENGTH (IN) WIDTH (IN) MANUFACTURER MODEL NUMBER NOTES 1 6 10 x 12 SERIES 0 550 79 78 71 69 65 63 70 66 62 59 59 63 14 48.5 18 NAILOR D35SE 1,2,3 1 8 10 x 12 SERIES 0 550 78 77 70 69 65 63 70 66 62 58 58 62 14 48.5 18 NAILOR D35SE 1,2,3 2 6 10 x 12 SERIES 0 550 75 72 63 58 54 52 65 62 58 57 60 63 14 48.5 18 NAILOR D35SE 1,2,3 2 8 10 x 12 SERIES 0 550 78 76 68 66 63 61 69 65 61 59 58 63 14 48.5 18 NAILOR D35SE 1,2,3 3 6 10 x 12 SERIES 0 550 75 71 65 60 54 51 64 62 59 59 61 64 18 51.25 18 NAILOR D35SE 1,2,3 3 8 10 x 12 SERIES 0 1,100 76 76 71 68 64 62 68 65 63 63 61 63 18 51.25 18 NAILOR D35SE 1,2,3 3 10 10 x 12 SERIES 0 1,215 76 76 73 70 67 65 69 66 63 63 61 62 18 51.25 18 NAILOR D35SE 1,2,3 4 10 14 x 12 SERIES 0 1,550 86 83 77 75 72 71 74 70 67 67 64 65 18 56.25 26 NAILOR D35SE 1,2,3 4 12 14 x 12 SERIES 0 1,550 85 82 76 75 72 71 74 1 70 1 67 1 67 63 1 64 1 18 1 56.25 26 NAILOR D35SE 1,2,3 5 12 14 x 12 SERIES 0 2,050 86 82 78 76 73 73 73 71 65 63 63 65 18 56.25 26 NAILOR D35SE 1,2,3 5 14 14 x 12 SERIES 0 2,050 85 81 77 76 73 73 73 71 65 63 63 65 18 56.25 26 NAILOR D35SE 1,2,3 NOTES: 1. REFER TO FAN POWERED AIR TERMINAL UNIT APPLICATION SCHEDULE FOR INDIVIDUAL UNIT REQUIREMENTS. 2. SOUND POWER LEVELS BASED ON 2.0" WG PRESSURE DROP ACROSS THE AIR TERMINAL UNIT WITH NO EXTERNAL ATTENUATION. 3. LENGTH DIMENSION INCLUDES ELECTRIC COIL SECTION. GRILLE, REGISTER, DIFFUSER SCHEDULE UNIT IDENTIFICATION DIFFUSER FLOW DIFFUSER PRESSURE MOUNTING MODEL FACE SIZE RANGE NECK SIZE DROP COLOR MATERIAL MANUFACTURER NOTES MARK NUMBER (IN) (CFM) (IN) (IN WG.) TYPE NUMBER 2424 0-100 6 0.1 LAY -IN WHITE ALUMINUM TITUS SPD 1,2,3 2424 101-200 8 0.1 LAY -IN WHITE ALUMINUM TITUS SPD 1,2,3 S 1 2424 201-380 10 0.1 LAY -IN WHITE ALUMINUM TITUS SPD 1,2,3 2424 381-600 12 0.1 LAY -IN WHITE ALUMINUM TITUS SPD 1,2,3 2424 601-900 1414 0.1 LAY -IN WHITE ALUMINUM TITUS SPD 1,2,3 2412 0-500 0.1 LAY -IN WHITE ALUMINUM TITUS 50F 1,2,3 R 1 2424 0-1000 - 0.1 LAY -IN WHITE ALUMINUM TITUS 50F 1,2,3 8x8 0-100 6 0.1 SURFACE WHITE ALUMINUM TITUS 50F 1,2,3 E 1 2412 201-380 10 0.1 LAY -IN WHITE ALUMINUM TITUS 50F 1,2,3 NOTES: 1. REFER TO REFLECTED CEILING PLANS EXACT LOCATION. PROVIDE ALL FRAMES AND ACCESSORIES AS REQUIRED FOR PROPER INSTALLATION. 2. FLEXIBLE DUCTWORK SHALL BE THE SAME SIZE AS THE DIFFUSER NECK OR AN EQUIVALENT ROUND DUCT. FLEXIBLE DUCTWORK SHALL BE SUPPORTED TO PREVENT KINKS OR BENDS. 3. COLOR TO BE SELECTED BY ARCHITECT FROM STANDARD COLORS. PLUMBING FIXTURE SCHEDULE MARK ITEM MFR/ MODEL DESCRIPTION WASTE PIPE VENT PIPE COLD WATER HOT WATER WASTE WATER NOTES IN IN IN IN FU FU WC-1 WATER CLOSET, FLOOR MOUNTED KOHLER K-3493 FLOOR MOUNTED, FLUSHMATE FLUSH, TWO PIECE ELONGATED TOILET, VITREOUS CHINA, 1.28 GPF, 4 2 1 - 4 4 12" ROUGH -IN SEAT BEMIS 1955CT OPEN FRONT LESS COVER, ELONGATED LAV-1 LAVATORY, WALL HUNG KOHLER K-12643 WALL MOUNTED, VITREOUS CHINA, 20" L x 18"W, CONCEALED ARM CARRIER 2 2 1/2 1/2 1 1 1 FAUCET CHICAGO 116.222.AB.1 DECK -MOUNTED BATTERY POWERED, SENSOR ACTIVATED ELECTRONIC FAUCET, 5-1/2" RIGID SPOUT, AND 0.5 GPM NON -AERATING LAMINAR OUTLET P-TRAP JUST MFR JT-200 1 112 " TUBULAR, CHROME PLATED BRASS P-TRAP DRAIN K-7108 1-1/4" CONNECTION WITHOUT OVERFLOW LAVATORY SHIELD TRUBRO 2018-KO-H LAV SHIELD, WHITE VINYL, VANDAL RESISTANT SK-1 EXAM SINK ELKAY LR1919 COUNTERTOP, 18 GAUGE 304 STAINLESS STEEL SINGLE BOWL, SINGLE HOLE, 19-1/2" x 19" x 7-1/2" DEEP, SOUND DAMPENED, 2 2 1/2 1/2 1 1 1 SELF -RIMMING FAUCET CHICAGO 786-G6AE36XK-317AB 4" WRIST BLADES, 6" RIGID/SWING GOOSENECK SPOUT, AND 1.5 GPM NON -AERATING LAMINAR OUTLET P-TRAP ELKAY LK500 1 112 " TUBULAR, CHROME PLATED BRASS P-TRAP DRAIN ELKAY LK99 3-1-2" DRAIN, TYPE 304 STAINLESS STEEL BODY STRAINER BASKET RUBBER SEAL AND TAILPIECE, 1-1/2" CONNECTION EW-1 EMERGENCY EYEWASH GUARDIAN G1895 WITH TMV G6020 DECK MOUNTED ADJACENT TO SINK. THERMOSTATIC MIXING VALVE, 1/2" CW AND 1/2" HW INLET AND 1/2" TEMPERED WATER OUTLET OF 1/2 1/2 MIXING VALVE NOTES: 1. PROVIDE CHECK VALVES UPSTREAM OF CW AND HW CONNECTIONS. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400 188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 I stantec.com 11 /08/2024 SWEDISH -EDMONDS MEDICAL PAVILION - SUITE 100 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT E Q U I P k 0.' : PARTMENT SCHEDULES ISSUANCE No. Description Date PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: SHEET NO M601 24034 :signer Author 1 1 2 3 4 5 6 7 8 7 10 11 1 2 FIRE ALARM Qo 4 HORN AND STROBE LIGHT, CEILING MOUNTED ©0 4 HORN AND STROBE LIGHT, WALL MOUNTED SPEAKER AND STROBE LIGHT, CEILING MOUNTED Y D04 SPEAKER AND STROBE LIGHT, WALL MOUNTED o; STROBE LIGHT, CEILING MOUNTED .Q. STROBE LIGHT, WALL MOUNTED O ELECTRICALLY OPERATED SMOKE OR FIRE/SMOKE DAMPER CONNECTION DH DOOR HOLDER �4 HORN, WALL MOUNTED �F PULL STATION ® INTERFACE RELAY OS SMOKE DETECTOR, CEILING MOUNTED NURSE CALL DOME LIGHT, WALL MOUNTED, SINGLE LAMP 2 NURSE ASSIST BUTTON x 3 CIRCUITS LUMINAIRES EMERGENCY NORMAL N/A 0 L01 LUMINAIRE IDENTIFICATION, SEE LUMINAIRES SCHEDULE N/A Da LOWER-CASE LETTER(S) NEAR LUMINAIRE DENOTE SWITCH LEG(S) RECESSED RECTANGULAR LUMINAIRE, DRAWN TO SCALE fo--1 H STRIP LUMINAIRE, LENGTH TO SCALE WALL MOUNTED RECTANGULAR LUMINAIRE, LENGTH 4 4 TO SCALE (NUMBER OF MOUNTING POINTS WILL VARY WITH THE LUMINAIRE LENGTH AND ARE NOT INDICATED.) In 0 0 000 RECESSED DOWNLIGHT LUMINAIRE �( 0 X )8(0)$( PENDANT MOUNTED LUMINAIRE LINEAR PENDANT MOUNTED LUMINAIRE, LENGTH TO ® SCALE (NUMBER OF MOUNTING POINTS WILL VARY WITH THE LUMINAIRE LENGTH AND ARE NOT INDICATED.) 2 2 WALL MOUNTED LUMINAIRE EXIT SIGN, FILLED SIDES INDICATE ILLUMINATED ® N/A ANNOTATION, ARROWS INDICATE DIRECTIONAL GRAPHICS WALL MOUNTED EXIT SIGN, FILLED SIDES INDICATE N/A ILLUMINATED ANNOTATION, ARROWS INDICATE DIRECTIONAL GRAPHICS N/A EXIT SIGN WITH EMERGENCY BATTERY PACK i N/A WALL MOUNTED EXIT SIGN WITH EMERGENCY BATTERY PACK N/A WALL MOUNTED EMERGENCY BATTERY PACK, NUMBER OF LAMPS NOT INDICATED a -► RECESSED LINEAR WALL WASH LUMINAIRE, LENGTH TO SCALE x LINEAR PENDANT MOUNTED WALL WASH LUMINAIRE, LENGTH TO SCALE a a a RECESSED WALL WASH LUMINAIRE SURFACE MOUNTED WALL WASH LUMINAIRE a a a a RECESSED ACCENT LUMINAIRE LIGHTING CONTROLS $ SINGLE POLE SWITCH fF INDICATES BATTERY POWER a LOWER-CASE LETTER(S) NEAR SWITCH DENOTE SWITCH LEG(S) 13 THREE-WAY SWITCH ID DIMMER SWITCH 0 $ LV MOMENTARY CONTACT LOW VOLTAGE SWITCH $ 0 OCCUPANCY SENSOR SWITCH FPS]PHOTO SENSOR CONTROL PS PHOTO SENSOR CONTROL, CEILING MOUNTED OR RELAY �T LOW VOLTAGE TRANSFORMER w 0 U m a 4 5 CIRCUITS RECEPTACLES EMERGENCY NORMAL q) q) SINGLE RECEPTACLE, 120V [ SINGLE RECEPTACLE, 120V, CEILING MOUNTED g qp DUPLEX RECEPTACLE, 120V 0 DUPLEX RECEPTACLE, 120V, CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE, 120V DOUBLE DUPLEX RECEPTACLE, 120V, CEILING MOUNTED SPLIT WIRED RECEPTACLE, 120V, TOP CONTROLLED, BOTTOM CONSTANTLY ENERGIZED # RECEPTACLE, NEMA # # I$ # RECEPTACLE, NEMA #, CEILING MOUNTED ## COMBINATION RECEPTACLE, NEMA # AND 120V N/A 1p[U INDICATES FULLY CONTROLLED N/A INDICATES TWIST LOCK N/A (16 INDICATES MOUNTED ABOVE COUNTER BACKSPLASH N/A ■ MULTI -SERVICE FLOOR BOX (RECEPTACLES AS INDICATED) N/A MULTI -SERVICE WALL BOX (RECEPTACLES AS INDICATED) RECEPTACLE TYPES qpD DEDICATED CIRCUIT qpG GROUND FAULT CIRCUIT INTERRUPTER GT GROUND FAULT CIRCUIT INTERRUPTER AND TAMPER RESISTANT T TAMPER RESISTANT WP WEATHER RESISTANT COVER ELECTRICAL EQUIPMENT G 208V OR 240V POWER PANELBOARD 121-2 480V OR 600V POWER PANELBOARD o EQUIPMENT CABINET OR PANEL Q ® EQUIPMENT CONNECTION, FILL INDICATES EMERGENCY CIRCUIT T—r GROUND BAR Aa MOTOR CONNECTION, 10 /& MOTOR CONNECTION, 30 ATS AUTOMATIC TRANSFER SWITCH SPD SURGE PROTECTIVE DEVICE TRANSFORMER, NOT TO SCALE Q TRANSFORMER, DRAWN TO SCALE CONTROLS ❑� NON -FUSED SAFETY SWITCH Ep FUSED SAFETY SWITCH, FUSE RATING INDICATED T AUTOMATIC DOOR PUSHPLATE DEAD FRONT GFCI EMERGENCY SHUTDOWN 0 ENCLOSED CIRCUIT BREAKER IM TOGGLE SWITCH, MOTOR RATED OR RELAY VFD VARIABLE FREQUENCY DRIVE STANDARD MOUNTING HEIGHTS ARCHITECT FOR HEEFER 0ITEMS BELOW ' ' ' ' eoV FINISHED CEILING ADA MAXIMUM UNOBSTRUCTED - - ADA MAXIMUM OBSTRUCTED UBE -� TOP OF BACKSPLASH COUNTER HEIGHT ADA MINIMUM HEIGHT FINISHED FLOOR M 00 22 6 WORK DEFINITION NEW WORK EXISTING ------ REMOVE EXISTING REMOVE EXISTING ELECTRICAL EQUIPMENT FUTURE TEMPORARY, AS NOTED ?:## KEY NOTE ??? EQUIPMENT IDENTIFICATION RACEWAYS RACEWAY CONCEALED IN CEILING OR WALL. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. — — — RACEWAY BELOW SLAB OR UNDERGROUND RACEWAY UP RACEWAY DOWN RACEWAY CONTINUATION RACEWAY STUB -OUT WITH BUSHING (DJUNCTION BOX, CEILING OR ABOVE CEILING MOUNTED JD JUNCTION BOX, WALL MOUNTED PB PULL BOX 00E0 0 ® 4 PT i i T 0 EHI SCHEMATICS 0 TRANSFER SWITCH r m TRANSFORMER 0 TRANSFORMER CONFIGURATION, DELTA TRANSFORMER CONFIGURATION, DELTA, CORNER _ GROUND OGENERATOR FM-E—TEq METER 0 OSPACE SPACE, FIXED BREAKER SPD SURGE PROTECTION DEVICE 0 0 CIRCUIT BREAKER, LOW VOLTAGE, FIXED • CONNECTION, CONNECTED CONNECTION, FEED FROM/TO CURRENT TRANSFORMER 1111 FUSE GROUND •—• GROUND STUD .. INDUCTOR NOT CONNECTED 3E POTENTIAL TRANSFORMER SHORT CIRCUIT CURRENT RATING, # INDICATES RATING PANELBOARD OR CABINET II V- - - Him 7 ABBREVIATIONS #/C MULTI -CONDUCTOR, # INDICTATES QUANTITY (D) DEMOLISH (E) EXISTING (N) NEW (R) EXISTING TO BE RELOCATED 1/C SINGLE CONDUCTOR A AMPS A/C AIR CONDITIONING UNIT AC ALTERNATING CURRENT ACH ABOVE COUNTER HEIGHT AF AMPFRAME AFC ABOVE FINISHED CEILING AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM ALT ALTERNATE ARCH ARCHITECTURAL AS AMP SWITCH AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AVG AVERAGE AWG AMERICAN WIRE GAUGE BKR BREAKER BLDG BUILDING C CONDUIT CB CIRCUIT BREAKER CIRC CIRCULATING CKT CIRCUIT CLG CEILING CO CONDUIT ONLY COMM COMMUNICATIONS CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CR CRITICAL BRANCH CT CURRENT TRANSFORMERS CTR CENTER CU COPPER D DEDICATED DC DIRECT CURRENT DIET DETAIL DIA DIAMETER DIM DIMENSION DISC DISCONNECT DIV DIVISION DL DAMP LOCATION DN DOWN DP DISTRIBUTION PANEL DWG DRAWING EA EACH EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ELEC ELECTRICAL ELEV ELEVATOR EM EMERGENCY EM GEN EMERGENCY GENERATOR EMT ELECTRICAL METALLIC TUBING ENCL ENCLOSURE EPO EMERGENCY POWER OFF EQ EQUIPMENT BRANCH EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXH EXHAUST F&I FURNISHED AND INSTALLED FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FIB FLOOR BOX FCU FAN COIL UNIT FLR FLOOR FLUOR FLUORESCENT FP FIRE PROTECTION FS FUSIBLE SWITCH FU FUSE G,GND GROUND GA GAUGE GAL GALLONS GC GENERAL CONTRACTOR GEN GENERATOR GFI, GFCI GROUND FAULT (CIRCUIT) INTERRUPTER H HOT CONDUCTOR HC HORIZONTAL CROSS CONNECT HK HOUSE KEEPING PAD HM HORIZONTALLY MOUNTED HOR HORIZONTAL HP HORSEPOWER HV HIGH VOLTAGE HW HOT WATER HZ HERTZ IDF INTERMEDIATE DISTRIBUTION FRAME IG ISOLATED GROUND INST INSTANTANEOUS JB JUNCTION BOX K KIRK KEY INTERLOCK KAIC KILO -AMPS INTERRUPTING CAPACITY 8 ABBREVIATIONS 9 10 PROJECT NOTES KV KILOVOLT KVA KILOVOLT -AMPERES KW KILOWATT LED LIGHT EMITTING DIODE LS LIFE SAFETY BRANCH LSIG LONG TIME, SHORT TIME, INSTANTANEOUS, GROUND FAULT LTG LIGHTING LV LOW VOLTAGE MAX MAXIMUM MC METAL CLAD CABLE MCA MINIMUM CIRCUIT AMPS MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MCCB MOLDED CASE CIRCUIT BREAKER MDF MAIN DISTRIBUTION FRAME MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUG ONLY MSB MAIN SWITCHBOARD MTD MOUNTED MTG MOUNTING MW MICROWAVE OVEN N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NTS NOT TO SCALE OD OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFE OWNER FURNISHED EQUIPMENT OL OVERLOAD OS OCCUPANCY SENSOR, OPTIONAL STANDBY P POLE PB PULL BOX PF POWER FACTOR PNL PANEL PR PAIR PVC POLYVINYL CHLORIDE PWR POWER REC RECESSED RECP RECEPTACLE REQD REQUIRED REX REQUEST TO EXIT RM ROOM RNC RIGID NON-METALLIC CONDUIT RO RACEWAY ONLY RSC, RGS RIGID STEEL CONDUIT SCCR SHORT CIRCUIT CURRENT RATING SEC SECURITY SECT SECTION SIM SIMILAR SPD SURGE PROTECTED DEVICE SPECS SPECIFICATIONS SPST SINGLE POLE SINGLE THROW SS STAINLESS STEEL ST SHUNT TRIP STD STANDARD SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR SYS SYSTEM TELE TELEPHONE TELECOM TELECOMMUNICATIONS TEMP TEMPERATURE TGB TELECOMMUNICATIONS GROUND BAR TMGB TELECOMMUNICATIONS MAIN GROUND BAR TP TAMPER RESISTANT TR TELECOMMUNICATIONS ROOM TV TELEVISION TYP TYPICAL UG UNDERGROUND UH UNIT HEATER LINO UNLESS NOTED OTHERWISE UNV UNIVERSAL VOLTAGE UPS UNINTERRUPTIBLE POWER SUPPLY USB UNIVERSAL SERIAL BUS V VOLTS VA VOLT -AMPS VAV VARIABLE AIR VOLUME VC VOLUME CONTROL VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WIRE, WATT WAP WIRELESS ACCESS POINT WG WIREGUARD WL WET LOCATION WP WEATHERPROOF WT WATERTIGHT XFMR TRANSFORMER O,PH PHASE 11 1. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS FROM AUTHORITIES HAVING JURISDICTION AND PAY ALL ASSOCIATED FEES. 2. LOCATE JUNCTION AND PULL BOXES AS REQUIRED TO ALLOW ACCESS AFTER EQUIPMENT AND APPURTENANCES ARE INSTALLED. COORDINATE EXACT LOCATIONS WITH THE OTHER TRADES. COORDINATE LOCATIONS AND ELEVATIONS OF ELECTRICAL DEVICES WITH DRAWINGS AND OTHER TRADES PRIOR TO INSTALLATION. 3. PROTECT PERMANENT BUILDING FINISHES FROM DAMAGE DURING CONSTRUCTION PERIOD. PROVIDE PLYWOOD OR SIMILAR MATERIAL UNDER EQUIPMENT OR MATERIALS STORED ON FLOORS, AND IN AREAS WHERE CONSTRUCTION MAY DAMAGE FINISHES. SURFACES OR FINISHES DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT THE COST OF THE CONTRACTOR AT FAULT. 4. CONTRACTORS SHALL COORDINATE LOCATIONS OF FIXTURES AND ELECTRICAL DEVICES INSTALLED IN OR ON THE CEILING WITH ARCHITECTURAL REFLECTED CEILING PLAN. CEILING MOUNTED ELECTRICAL DEVICES SHALL BE MOUNTED IN THE CENTER OF THE CEILING TILES, UNLESS OTHERWISE NOTED. 5. WHERE DIRECTED TO USE OR RETAIN EXISTING CIRCUITS, AND THE CIRCUIT NUMBERS DIFFER FROM THE DRAWING, UPDATE DIRECTORIES AND RECORD DRAWINGS. 6. PROPERLY SUPPORT PER CODE LOW VOLTAGE CABLING NOT IN CONDUIT. IN AREAS SUCH AS CORRIDORS DESIGNATED FOR NEW CEILINGS AND FINISHES, SUPPORT EXISTING ELECTRICAL DEVICES AND EQUIPMENT IN AND ABOVE THE CEILING, INCLUDING CONDUIT AND CABLING. PROVIDE PROPER PERMANENT SUPPORT AS NEEDED TO COMPLY WITH CODE AND TAKE WEIGHT OFF CEILING SUPPORTS. REMOVE AND REINSTALL ELECTRICAL DEVICES AND EQUIPMENT AS NEEDED FOR PAINTING, WALL COVERINGS, CEILINGS, AND FINISH WORK. REFER TO ARCHITECTURAL DRAWINGS. LOW VOLTAGE CABLING LOCATED IN EXPOSED STRUCTURE (CEILING) AREAS SHALL BE INSTALLED IN CONDUIT (OR CABLE TRAY, IF APPLICABLE) AND ROUTED TIGHT TO DECK. INSTALLATIONS NOT IN COMPLIANCE WITH THIS REQUIREMENT SHALL BE REMOVED AND REINSTALLED AT CONTRACTOR'S EXPENSE. 7. WHERE PROJECT PHASING IS INDICATED IN ANY PART OF THE WORKING DOCUMENT PACKAGE, ELECTRICAL CONTRACTOR IS TO PLAN WORK SO AS TO FACILITATE SUCH PHASING. 8. FOR BRANCH CIRCUITS OVER 75' (25 METERS) IN LENGTH (TOTAL ONE WAY) FROM THE PANEL, THE ELECTRICAL CONTRACTOR SHALL CALCULATE THE VOLTAGE DROP AND PROVIDE AN APPROPRIATE CONDUCTOR SIZE TO ACHIEVE NO MORE THAN 3% MAXIMUM ALLOWABLE VOLTAGE DROP. 9. DO NOT SCALE THE DRAWINGS. BECAUSE OF THE SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS OR OTHER SIMILAR ITEMS WHICH MAY BE REQUIRED TO MAKE A COMPLETE OPERATING SYSTEM. CAREFULLY INVESTIGATE CONDITIONS AFFECTING WORK AND INSTALL WORK IN SUCH MANNER THAT INTERFERENCES BETWEEN PIPES, CONDUITS, DUCTS, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL FEATURES SHALL BE AVOIDED. PROJECT DEMOLITION NOTES 1. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE, AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT, SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY THE OWNER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. PRIOR TO COMMENCING WITH DEMOLITION, IDENTIFY ALL POWER, LIGHTING, COMMUNICATION, AND SIGNAL CIRCUITS PASSING THROUGH THE DEMOLITION AREA OR EXTENDING BEYOND THE DEMOLITION AREA. COORDINATE WITH DEMOLITION WORK OF OTHER TRADES. 2. THE EXISTING BUILDING MUST BE KEPT IN OPERATION AT ALL TIMES. MAINTAIN ELECTRICAL SERVICES AND SYSTEMS AT ALL TIMES TO AREAS BEYOND THE CONSTRUCTION AREA AND MAINTAIN CONTINUITY OF FIRE ALARM, LIFE SAFETY AND SECURITY SYSTEMS TO ALL OCCUPIED AREAS OF THE BUILDING THROUGHOUT THE CONSTRUCTION PERIOD. PROVIDE TEMPORARY WIRING AND BRANCH CIRCUITING AS NECESSARY TO MAINTAIN OPERATION OF EXISTING CIRCUITS AND SYSTEMS EXTENDING BEYOND REMODEL AREA. ASSUME FULL RESPONSIBILITY FOR ANY DISRUPTION TO EXISTING SERVICES. RECONNECT ANY SERVICES WHICH ARE TO REMAIN, AND WHICH HAVE BEEN DISCONNECTED DURING DEMOLITION OR CONSTRUCTION. ARRANGE WORK IN SUCH A MANNER THAT INTERRUPTIONS IN SERVICES OCCUR ONLY AT PRE -SCHEDULED TIMES. CARRY OUT THE WORK WITH A MINIMUM OF NOISE, DUST AND DISTURBANCE. 3. PERMANENTLY REMOVE ABANDONED ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, ELECTRICAL DEVICES, POWER AND SIGNALLING WIRING DEVICES AND ASSOCIATED WIRE, RACEWAYS, AND/OR JUNCTION BOXES. THE REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT PRESENTLY CONCEALED IN EXISTING CONSTRUCTION SHALL BE COORDINATED WITH THE OWNER PRIOR TO REMOVAL OR RELOCATION. RACEWAYS AND CONDUCTORS SHALL BE REMOVED BACK TO THE SOURCE OR NEAREST REMAINING JUNCTION BOX OR DEVICE AS FAR AS PRACTICAL, OR WHERE COMPLETE REMOVAL NOT PRACTICAL, RENDERED PERMANENTLY SAFE. 4. ANY EXISTING SYSTEM OUTAGES SHALL BE OF MINIMUM DURATION AND AT A TIME ACCEPTABLE TO THE OWNER, ARRANGED A MINIMUM OF 10 WORKING DAYS IN ADVANCE. LONGER NOTICES AND/OR ADDITIONAL RESTRICTIONS PERTAINING TO OUTAGES MAY BE REQUIRED IN SOME INSTANCES, AS PER SPECIFICATIONS. VERIFY PROTOCOL WITH ALL PROJECT STAKEHOLDERS INCLUDING OWNER, TENANT, CONSTRUCTION MANAGER AND/OR USER GROUP(S) AS APPLICABLE. 5. ELECTRICAL EQUIPMENT, FIXTURES, AND/OR DEVICES SCHEDULED TO REMAIN OR TO BE RELOCATED THAT ARE DAMAGED DURING DEMOLITION SHALL BE REPLACED WITH SIMILAR TYPE AS APPROVED BY THE OWNER, AT NO ADDITIONAL CHARGE TO THE OWNER. 6. IN THE EVENT THAT DEMOLITION WORK AFFECTS THE STRUCTURAL SUPPORT OF EXISTING ELECTRICAL EQUIPMENT THAT IS TO REMAIN IN SERVICE, IT SHALL BE RE -SUPPORTED IN ACCORDANCE WITH ALL APPLICABLE CODES. PROVIDE TEMPORARY SUPPORTS WHERE REQUIRED. 7. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT OR REQUIRED FIRE SEALANT. UNUSED RACEWAYS ABOVE ACCESSIBLE CEILINGS SHALL BE REMOVED. 8. ELECTRICAL MATERIAL SCHEDULED FOR REMOVAL IS TO BE REMOVED FROM THE SITE AND PROPERLY DISPOSED OF AS PART OF THIS CONTRACT. ANY ELECTRICAL MATERIAL THE OWNER WISHES TO RETAIN TO BECOME THE PROPERTY OF THE OWNER AND TO BE REMOVED AND PLACED AT A LOCATION ON THE SITE AS DIRECTED BY THE OWNER. 9. THE DEMOLITION DRAWINGS SHOW THE GENERAL SCOPE OF THE DEMOLITION AND NOT EXACT DETAILS OR TOTAL EXTENT. FOR EXACT DETAILS AND TOTAL EXTENT, EACH SERVICE MUST BE CAREFULLY CHECKED ON SITE. BEFORE REMOVING SERVICES FOLLOW THE SERVICE THROUGH TO ENSURE OTHER AREAS OF THE BUILDING ARE NOT AFFECTED. DRAWING INDEX NO. DRAWING NAME E0.00 SYMBOLS AND ABBREVIATIONS E0.01 ELECTRICAL SPECIFICATIONS E0.02 OVERALL ELECTRICAL PLAN LEVEL 1 E1.00 SUITE 100 LIGHTING DEMOLITION PLAN LEVEL 1 E1.01 SUITE 100 ELECTRICAL DEMOLITION PLAN LEVEL 1 E2.00 SUITE 100 LIGHTING PLAN LEVEL 1 E3.00 SUITE 100 ELECTRICAL PLAN LEVEL 1 E4.00 ELECTRICAL RISER E5.00 TELECOM RISER E6.00 PANEL SCHEDULES tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (N Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com OF WA �61 C� z w 203415 �Gr sT�R �SSIONAL 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT SYM B C� LEF CES/�EN1]CI�NT L.\ ,, 11 ABBREVIATIONS ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: NCA DRAWN BY: AD 1 2 3 4 5 6 7 8 9 10 11 SHEET NO EOmOO 1 `a 3 4 5 6 ELECTRICAL SPECIFICATIONS 7 8 10 11 tgb architects x c� W 0 U m a SECTION 260100 - GENERAL PROVISIONS PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. A. CODES CONFORM TO THE NATIONAL ELECTRICAL CODE AND ALL OTHER CODES AND REGULATIONS AS ADOPTED AND AMENDED BY THE STATE OF WASHINGTON AND CITY OF EDMONDS INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). B. PERMITS AND FEE CONTRACTOR TO OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. C. COORDINATION CONTRACTOR TO COORDINATE ELECTRICAL WORK WITH OTHER TRADES. D. WARRANTY PROVIDE WARRANTY FOR ONE FULL YEAR AFTER COMPLETION. E. CONTRACT DRAWINGS RACEWAYS AND OUTLET BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND THE LAYOUT DOES NOT NECESSARILY SHOW THE TOTAL NUMBER OF RACEWAYS NOR THEIR EXACT LOCATION. THE CONTRACTOR SHALL PROVIDE ALL RACEWAYS, BOXES, CABLES, AND OTHER MATERIALS REQUIRED FOR THE COMPLETE ELECTRICAL SYSTEMS SHOWN OR INDICATED ON THE CONTRACT DRAWINGS. F. RECORD DRAWINGS AT THE CONCLUSION OF CONTACT WORK, PROVIDE THE OWNER WITH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WITH ALL CHANGES CLEARLY AND LEGIBLY MARKED TO REFLECT THE AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE LABELED "AS -BUILT" AND CERTIFIED BY THE CONTRACTOR FOR ACCURACY. G. MAINTENANCE MANUALS COMPLETE FOR EVERY SYSTEM. PROVIDE MANUAL TO OWNER IN ELECTRONIC MEDIUM. H. QUALITY ASSURANCE 1. MATERIALS AND SYSTEMS: PROVIDE UL LISTED AND LABELED MATERIALS WHERE LISTING SERVICE IS NORMALLY PROVIDED FOR A GIVEN PRODUCT. PROVIDE NEW AND SHIP TO JOBSITE IN ORIGINAL MANUFACTURER'S CONTAINERS OR BUNDLES. 2. WORKMANSHIP: ARRANGE WORK TO OBTAIN COORDINATED INSTALLATION. 3. ROUTING: EXACT ROUTING OF WIRING AND LOCATIONS OF OUTLETS, PANELS, ETC. SHALL BE GOVERNED BY STRUCTURAL CONDITIONS, OBSTRUCTIONS, AND EXISTING CONDITIONS. ARCHITECT RESERVES THE RIGHT AT NO INCREASE IN PRICE, TO MAKE REASONABLE CHANGES IN LOCATIONS OF ELECTRICAL ITEMS EXPOSED AT CEILING AND/OR ON WALLS. I. COORDINATION 1. WORK OUT ALL "TIGHT" CONDITIONS INVOLVING WORK UNDER THIS CONTRACT IN ADVANCE OF INSTALLATION. 2. COORDINATE ALL ELECTRICAL POWER AND CONTROL WIRING REQUIREMENTS OF MECHANICAL EQUIPMENT. 3. CONFIRM ALL ELECTRICAL EQUIPMENT AND SYSTEM PROGRAMMING NOMENCLATURE REQUIREMENTS WITH THE OWNER PRIOR TO SUBMITTALS AND ROUGH -IN. CONFORM TO ALL NAMING CONVENTIONS DEFINED THROUGHOUT THE PROJECT. SECTION 260126 - TESTING A. FURNISH ALL LABOR AND TEST EQUIPMENT AS REQUIRED UNDER THIS SECTION. B. FACILITIES ENGINEERING REPRESENTATIVE NEEDS TO BE PRESENT FOR FINAL TESTING. C. TEST ALL PANELS AND/OR BRANCH CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE WIRING AS REQUIRED. TEST EACH INDIVIDUAL CIRCUIT AT PANEL FOR PROPER OPERATION. D. AT COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT DEFECTS. SECTION 260500 - BASIC MATERIALS AND METHODS INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. A. MATERIALS ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES, OR OTHER APPROVED TESTING ORGANIZATION, AND SHALL BE SO LABELED. B. SUBSTITUTIONS SHALL BE REVIEWED BY THE ENGINEER. C. WORKMANSHIP SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. D. NOISE TRANSMISSION TO PREVENT NOISE TRANSMISSION (IN NEW CONSTRUCTION) BETWEEN ADJOINING ROOMS, ALL DEVICES ON OPPOSITE SIDES OF WALL TO BE SPACE A MINIMUM OF 6" APART (HORIZONTALLY PREFERRED). E. BRANCH CIRCUITING NO MORE THAN SIX CURRENT CARRYING CONDUCTORS IN ANY ONE (1) HOMERUN. F. GROUNDING PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR IN ALL EQUIPMENT AND RECEPTACLE BRANCH CIRCUITS. SIZE PER NEC. G. SUBMITTALS SUBMIT ELECTRONIC COPIES CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: 1. LIGHTING 2. LIGHTING CONTROLS 3. NURSE CALL 4. FIRE ALARM H. CUTTING AND PATCHING DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. I. PAINTING TOUCH-UP TO MATCH FACTORY PAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. J. CLEAN UP CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. SECTION 260510 - EXISTING SYSTEMS A. EXISTING SYSTEMS AND SYSTEMS ADJACENT TO THE WORK SHALL BE INVESTIGATED THOROUGHLY. ANY DAMAGE RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ASSURE CONTINUING OPERATION AND INTEGRITY DURING AND AT COMPLETION OF THE PROJECT AT NO INCREASE IN CONTRACT COST. ANY EXISTING WIRING SERVING DEVICES REMAINING IN SERVICE AND INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT, SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS, EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY ENGINEER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. THE BUILDING WILL CONTINUE OPERATION DURING THE WORK AND IT IS ESSENTIAL THAT NO SYSTEMS OPERATION BE INTERRUPTED UNLESS SCHEDULED WITH THE OWNER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR UNSCHEDULED INTERRUPTIONS AND EXPEDIENT REPAIR. B. EXISTING SYSTEMS CONCEALED 1. THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. 2. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE THEIR OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOLITION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. C. EXISTING SYSTEM DRAWINGS THE DRAWINGS SHOW PORTIONS OF THE EXISTING SYSTEMS WHICH ARE DERIVED FROM RECORD DRAWINGS. THE DRAWINGS ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. THE CONTRACTOR SHALL ASSUME THERE IS 20% MORE ELECTRICAL SYSTEMS THAN SHOWN ON THE DEMOLITION AND EXISTING SYSTEM DRAWINGS. D. DEMOLITION WORK CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT IN THE AREA BEING REMODELED WHICH IS NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT. THE DEFINITION OF ELECTRICAL EQUIPMENT IS ANY EQUIPMENT MENTIONED IN THE NATIONAL ELECTRICAL CODE. E. PREMIUM TIME PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE, AS SHOWN ON THE DRAWINGS AND AS NOTED IN OTHER DIVISIONS OF THE SPECIFICATIONS. F. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. G. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. H. EXISTING MATERIALS ALL MATERIALS WHICH ARE A PART OF THE BUILDING SHALL REMAIN THE PROPERTY OF THE OWNER. I. EXISTING MATERIALS TO BE REINSTALLED EXISTING MATERIALS AND EQUIPMENT (EXCEPT INTERIOR, UNDAMAGED RACEWAYS) THAT ARE REMOVED AS A PART OF THE WORK OR STORED IN SURPLUS SHALL NOT BE REINSTALLED AS A PART OF THE NEW SYSTEMS UNLESS SPECIFICALLY NOTED OR AUTHORIZED IN WRITING BY THE OWNER. FORWARD A COPY OF THE AUTHORIZATION TO THE ENGINEER. THE REQUIREMENTS OF THE SPECIFICATIONS (I.E., CONDITION, INSTALLATION, TESTING, ETC.) SHALL APPLY AS IF THE MATERIALS WERE NEW, FURNISHED BY THE CONTRACTOR. J. EXISTING MATERIALS NOT TO BE REINSTALLED ALL MATERIAL TO BE DEMOLISHED AND DEBRIS SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. K. EXISTING RACEWAYS 1. THE CONTRACTOR MAY REUSE THE EXISTING RACEWAYS IF NO OTHER SYSTEMS OCCUPY THE RACEWAY, RACEWAYS AND ENCLOSURES ARE ELECTRICALLY AND MECHANICALLY CONTINUOUS AND NEW WIRING IS PROVIDED. NO WARRANTY IS MADE AND THE CONTRACTOR SHALL ASSUME THE RISK OF USING EXISTING OUTLET BOXES AND RACEWAY SYSTEMS. 2. THE CONTRACTOR SHALL RELOCATE EXISTING RACEWAYS IN THE AREA OF WORK AS REQUIRED TO SUPPORT INSTALLATION OF MECHANICAL EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR TO DETERMINE THE EXTENT OF EXISTING CONDUITS THAT NEED TO BE RELOCATED L. EXISTING CONDITIONS EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF ELECTRICAL WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES OR DETRIMENTAL CONDITIONS HAVE BEEN CORRECTED. REPORT DEFICIENCIES OR DETRIMENTAL CONDITIONS OF EXISTING ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH OR RECEIVE OTHER WORK. FAILURE TO SO REPORT SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE RECEPTION OF ELECTRICAL WORK. M. EXISTING SYSTEMS MAINTAINED GENERAL REROUTE EXISTING CIRCUITS THAT ARE INTERRUPTED AS A RESULT OF THIS CONTRACT THAT SERVE DEVICES TO REMAIN IN SERVICE. 1. POWER CIRCUITS TRACE OUT AND IDENTIFY LOADS AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING, SCHEDULE OUTAGE AND RECONNECT LOADS TO TEMPORARY WIRING. PROVIDE NEW WIRING IN NEW LOCATION. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING, AND CONNECT LOADS TO NEW WIRING. N. DEMOLITION ELECTRICAL EQUIPMENT FREE STANDING OR SURFACE MOUNTED, RACEWAY (EXPOSED) AND CONDUCTORS; WHICH ARE NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT SHALL BE REMOVED. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES EMBEDDED IN CONCRETE SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. ALL UNUSED RACEWAYS ABOVE CEILINGS SHALL BE REMOVED. CONTRACTOR SHALL REMOVE ALL FLOOR, WALL OR CEILING MOUNTED ELECTRICAL EQUIPMENT IN THE "DEMOLITION AREA" INDICATED ON THE DRAWINGS EVEN IF THE EQUIPMENT/OR DEVICE IS NOT SHOWN ON THE PROJECT DRAWINGS. IF CONTRACTOR QUESTIONS WHETHER A PARTICULAR DEVICE IS TO BE REMOVED, NOTIFY THE ENGINEER NOTING TYPE AND LOCATION OF DEVICE. IF SO DIRECTED THE CONTRACTOR SHALL MAINTAIN THE EXISTING DEVICE IN SERVICE WITHOUT ANY CHANGE IN CONTRACT PRICE. 0. POWER OUTAGES 1. SCHEDULED OUTAGES. THE EXISTING FACILITY WILL CONTINUE ITS NORMAL OPERATION DURING THE CONSTRUCTION WORK; THEREFORE IT IS REQUIRED THAT THE CONTRACTOR SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER. SUBMIT A WRITTEN REQUEST FOR A POWER OUTAGE AT LEAST ONE WEEK IN ADVANCE IDENTIFYING THE AREAS, AND SYSTEMS THAT WILL BE AFFECTED, TIME AND DURATION OF THE POWER OUTAGE. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH THE OUTAGE AND SHALL RE -NOTIFY THE OWNER VERBALLY AT LEAST ONE HOUR PRIOR TO THE OUTAGE AND ALSO NOTIFY THE OWNER WHEN THE OUTAGE IS COMPLETED. 2. UNSCHEDULED OUTAGES. IN THE EVENT THAT THE CONTRACTOR'S WORK CAUSES OR CONTRIBUTES TO AN UNSCHEDULED SYSTEM(S) OUTAGE (OR OTHER SYSTEM FAULT), THE CONTRACTOR IS RESPONSIBLE FOR IMMEDIATELY CORRECTING THE PROBLEM. INCLUDED (AS EXAMPLES) SHALL BE ANY PREMIUM TIME REQUIRED TO STAY ON THE JOB SITE UNTIL PROBLEM IS CORRECTED AND AIR FREIGHT FOR PARTS NOT LOCALLY AVAILABLE. P. ACCESS TO PERFORM WORK CAREFULLY REMOVE, STORE OR TEMPORARILY HANG AND RE -INSTALL IN UNDAMAGED CONDITION ALL ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, AND CEILING TILES WHERE ACCESS TO PERFORM WORK IS REQUIRED. CLEAN PRIOR TO RE -INSTALLATION. SECTION 260519 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES A. PROVIDE ALL WIRE AND CABLE COMPLETE. COPPER, INSULATED FOR 600V. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THWN/THHN OR XHHW-2. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. B. CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70/ICEA S-95-658 FOR TYPE THHN-THWN AND TYPE SO. C. SPLICES SOLDERLESS TYPE ONLY. PRE -INSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER) BOLT OR COMPRESSION SET TYPE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. D. TERMINATIONS COMPRESSION SET, BOLTED OR SCREW TERMINAL. CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. E. COLOR CODE 480 MARKING BRN, ORG, YELL, GRAY NEUTRAL 208 MARKING BLK, RED, BLU, WHITE NEUTRAL F. BRANCH CIRCUITS COPPER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG AND LARGER. G. ALL 480/277V WIRING WILL BE SEPARATED FROM THE 208/120V WIRING AT ALL TIMES. EXCEPTIONS: MOTOR CONTROLS SECTION 260526 - GROUNDING A. PROVIDE A GROUNDING SYSTEM FOR EQUIPMENT AND DEVICE GROUND AS REQUIRED BY CODE. SECTION 260533 - RACEWAYS AND BOXES A. PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTION FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. B. PROVIDE 1" RACEWAY FOR HOMERUNS AND MAJOR CEILING CONDUIT RUNS. RACEWAY DROPS DOWN WALLS AND RACEWAY CARRYING 2 CURRENT CARRYING CONDUCTORS CAN BE 3/411. MINIMUM RACEWAY SIZE IS 3/4". C. PROVIDE PULLWIRE IN ALL EMPTY RACEWAYS. D. INTERIOR RACEWAYS ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON, AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. E. RACEWAY PENETRATIONS PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL, OR T & B FLAMESAFE. F. PROVIDE AND SIZE OUTLET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES, AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE ANY SPECIALTY INSTALLATION REQUIREMENTS DUE TO FIRE RATINGS, CORE WALLS, ETC. G. INTERIOR WIRING: RESSED STEEL, ZINC COATED WITH PLASTER RING WHERE APPLICABLE. MOUNT OUTLET BOXES FOR RECEPTACLES AND OTHER DEVICES AT 18", UNLESS OTHERWISE NOTED. SECTION 265100 - INTERIOR LIGHTING - SEE SCHEDULE FOR ADDITIONAL INFORMATION. A. ACTION SUBMITTALS PRODUCT DATA FOR TYPE OF LIGHTING FIXTURE ARRANGED IN ORDER OF FIXTURE DESIGNATION. INCLUDE PHYSICAL DESCRIPTION. B. COORDINATION COORDINATE LAYOUT AND INSTALLATION OF FIXTURES AND SUSPENSION SYSTEM WITH OTHER CONSTRUCTION THAT PENETRATES CEILINGS OR IS SUPPORTED BY THEM; HVAC, FIRE - SUPPRESSION, PARTITIONS. C. WARRANTY PROVIDE 5-YEAR WARRANTY ON ALL FIXTURES AND FIXTURE COMPONENTS. D. GENERAL FIXTURE CONSTRUCTION FIXTURES SHALL BE FREE OF LIGHT LEAKS, SHEET METAL SHALL BE FREE FROM MARKS, GOUGES, AND DENTS, AND FINISHED AS NOTED. LAMPS SHALL BE HELD SECURELY IN PLACE AGAINST NORMAL VIBRATIONS AND MAINTENANCE HANDLING. E. LAMPS LED SHALL HAVE A MINIMUM OF 80 CRI UNLESS NOTED OTHERWISE IN FIXTURE SCHEDULE. COLOR TEMP SHALL NOT VARY +/-100K AT INSTALLATION. SECTION 260923 - LIGHTING CONTROL DEVICES LIGHTING CONTROL SYSTEM DESIGNED BASED ON WATT STOPPER OR N-LIGHT STAND ALONE LIGHTING CONTROL SYSTEM. OFFICES AND CONFERENCE ROOMS SHALL BE PROGRAMMED TO BE MANUAL "ON", AUTOMATIC "OFF". OPEN WORK AREAS SHALL BE PROGRAMMED TO BE AUTOMATIC "ON", AUTOMATIC "OFF". A. OCCUPANCY SENSORS 1. THE OCCUPANCY SENSOR SYSTEM SHALL SENSE THE PRESENCE OF HUMAN ACTIVITY WITHIN THE DESIRED SPACE AND FULLY CONTROL THE ON/OFF FUNCTION OF THE LOADS AUTOMATICALLY. SENSORS SHALL TURN ON THE LOAD WITHIN 2 FEET OF ENTRANCE AND SHALL NOT INITIATE "ON" OUTSIDE OF ENTRANCE. 2. UPON DETECTION OF HUMAN ACTIVITY BY THE DETECTOR, A TIME DELAY SHALL BE INITIATED TO MAINTAIN THE LIGHT ON FOR A FIELD ADJUSTABLE PRE-SET PERIOD. 3. SENSORS MUST BE DESIGNED TO WORK IN CONJUNCTION WITH REMOTE POWER PACKS, RELAYS, OR OTHER CONTROL SYSTEMS. SENSORS MUST OPERATE WITH A CLASS 2, LOW VOLTAGE WIRING STRATEGY. SENSORS MUST BE CAPABLE OF BEING PARALLEL WIRED FOR MULTI -SENSOR APPLICATIONS. B. SWITCH BOX OCCUPANCY SENSORS SINGLE POLE, MANUAL "ON," AUTOMATIC "OFF." C. POWER PACKS POWER PACKS MUST BE DESIGNED TO POWER AND ACCEPT SIGNALS FROM REMOTE LOW VOLTAGE SENSORS, OR OTHER CONTROL DEVICES, AND DIRECTLY SWITCH THE LINE VOLTAGE OF THE DESIRED LOAD CONTROLLED. D. SYSTEM STARTUP AND COMMISSIONING COMMISSIONING SHALL TAKE PLACE PRIOR TO DEMONSTRATION OF SYSTEM TO OWNER. AFTER THE SYSTEM HAS BEEN INSTALLED THE CONTRACTOR SHALL PROVIDE MANUFACTURER'S RECOMMENDED COMMISSIONING WITH FACTORY TRAINED AND AUTHORIZED TECHNICIANS ON -SITE, TO: 1. VERIFY THAT THE CONTRACTOR HAS PROPERLY INSTALLED AND INTERCONNECTED ALL NECESSARY COMPONENTS. 2. VERIFY CORRECT OPERATION OF ALL SYSTEM COMPONENTS. 3. VERIFY THAT ALL SWITCH AND CONTACT INPUTS ARE IN COMPLIANCE WITH CONTRACT REQUIREMENTS. 4. OCCUPANCY SENSORS: ADJUST SENSITIVITY AND TIME DELAY OF THE OCCUPANCY SENSOR AND TEST TO ENSURE IT PROVIDES APPROPRIATE RESPONSE. SET INITIAL TIME DELAY FOR 15 MINUTES. 5. DUAL TECHNOLOGY TYPE OCCUPANCY SENSORS: IF INTERFERENCES OCCUR, DISABLE EITHER PIR OR ULTRASONIC TECHNOLOGY AS APPROPRIATE FOR APPLICATION. 6. SUBMIT COMPLETED VERIFICATION CHECKLIST. SECTION 262816 - DISCONNECTS A. PROVIDE DISCONNECT SWITCHES FOR EQUIPMENT, SIZED PER CODE. EQUIPMENT SIZING SHOWN ON DRAWINGS SHALL BE CONFIRMED AND REVISED AS REQUIRED TO MEET NEC. SECTION 275223 - NURSE CALL SYSTEM A. BASIS OF DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS PROVIDE CORNELL VISUAL 4000 SERIES NURSE CALL SYSTEM OR APPROVED EQUAL. B. SYSTEM COMPONENTS 1. STAFF ASSIST BUTTON: STAINLESS STEEL FACEPLATE WITH PUSH BUTTON. INTEGRAL INDICATOR LIGHT NOTING CALL PLACED. PUSH BUTTON ACTIVES CORRIDOR DOME LIGHT. CALL CANCELLED AFTER ACTIVATION OF PUSH BUTTON. 2. CORRIDOR DOME LIGHT (CORNELL P/N LS-101AP OR APPROVED EQUAL): WHITE LIGHT WITH TRANSLUCENT PLASTIC COVER AND PULSATING TONE INITIATED FROM STAFF ASSIST BUTTON. STAINLESS STEEL FACEPLATE WITH MOUNTING SCREWS. 3. POWER SUPPLY: CONVERT 120VAC TO 24VDC. POWER SUPPLY SIZED TO SERVE NUMBER OF NURSE CALL DEVICES. SECTION 283111.0 - FIRE ALARM SYSTEM EXTEND EXISTING ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM THAT FULLY COMPLIES WITH THE LOCAL FIRE CODE. IF ANY CONFLICT OCCURS BETWEEN GOVERNMENT ADOPTED CODE RULES AND THESE CONTRACT DOCUMENTS, THE CODES ARE TO GOVERN. A. OPERATION ACTIVATION OF ANY INITIATION DEVICE SHALL IMMEDIATELY CAUSE ALL FIRE ALARM HORNS TO SOUND A CONTINUOUS TONE SIGNAL, VISUAL ALARM LIGHTS TO FLASH AND TRANSMIT AN ALARM TO THE FIRE DEPARTMENT. B. SUPERVISION THE SYSTEM SHALL BE SUPERVISED TO SOUND AN AUDIBLE AND VISUAL TROUBLE SIGNAL UPON THE OCCURRENCE OF ANY OPEN OR GROUNDED CIRCUITS. PROVIDE A SEPARATE INDICATOR LAMP FOR EACH ZONE. C. CONTRACTOR DESIGN RACEWAYS, ROUTING AND SYSTEM WIRING IS NOT SHOWN ON THE PLANS. IT SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM SYSTEM SUPPLIER TO DESIGN CONDUIT ROUTING AND WIRING, AND TO SHOW THE SAME ON THE SHOP DRAWINGS. CIRCUITS SHALL BE CLASS B. D. SHOP DRAWINGS PREPARE FLOOR PLAN BACKGROUNDS AND SHOW CONDUIT ROUTING, DEVICE LOCATIONS, END OF LINE RESISTORS, AND WIRE COUNT BETWEEN DEVICES. SHOW FIRE ALARM ZONES. UPDATED DRAWINGS OF THE ORIGINAL FIRE ALARM SHOP DRAWINGS ARE ACCEPTABLE. SUBMIT DRAWINGS AND OBTAIN APPROVAL OF THE "AUTHORITY HAVING JURISDICTION" (AHJ). E. APPROVED MANUFACTURERS EST EQUIPMENT TO MATCH EXISTING EQUIPMENT. F. COMPONENTS SHALL BE MANUFACTURER'S STANDARD. 1. SMOKE DETECTORS: PHOTOELECTRIC TYPE, LOW PROFILE, SEMI -FLUSH MOUNTED WITH VISUAL INDICATION OF TROUBLE/ALARM CONDITION. 2. PULL STATIONS: COMPLY WITH UL 38, FINISHED RED WITH MOLDED RAISED LETTER OPERATION INSTRUCTIONS, SINGLE ACTION PULL -LEVER WITH INTEGRAL ADDRESSABLE MODULE TO COMMUNICATE TO CONTROL UNIT. KEYED RESET. 3. STROBE: XENON STROBE COMPLY WITH UL 1971 WITH CLEAR POLYCARBONATE LENS, THE WORD "FIRE" ENGRAVED IN MINIMUM 1-INCH HIGH LETTERS. FIELD SELECTABLE 15/30/75/110 cd LEVELS. FLASHING SHALL BE SYNCHRONIZED WITH OTHER EXISTING AND NEW UNITS. 4. HORNS: ELECTRIC -VIBRATING -POLARIZED TYPE, 24-V DC; WITH PROVISION FOR HOUSING THE OPERATING MECHANISM BEHIND A GRILLE. COMPLY WITH UL 464. HORNS SHALL PRODUCE A SOUND -PRESSURE LEVEL OF 90 DBA, MEASURED 10 FEET (3 M) FROM THE HORN, USING THE CODED SIGNAL PRESCRIBED IN UL 464 TEST PROTOCOL. G. INSTALLATION OBTAIN A PERMIT AND APPROVED SHOP DRAWINGS FROM THE AHJ PRIOR TO INSTALLING EQUIPMENT. ALL WIRING SHALL BE CONTAINED IN STEEL RACEWAYS. AFFIX PERMANENT WIRE MARKERS TO ALL CONDUCTORS AT TERMINATIONS. NUMBER 16 GAUGE WIRE SHALL HAVE A MAXIMUM OF 7 STRANDS. H. TESTING TEST EACH DEVICE, ALL FEATURES OF THE SYSTEM ON NORMAL AND BATTERY POWER AND DEMONSTRATE SATISFACTORY OPERATION TO THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION. OBTAIN APPROVAL OF THE AHJ IN WRITING. I. RECORD DOCUMENTS PROVIDE OPERATION AND MAINTENANCE MANUALS AND RECORD DRAWINGS TO SHOW ACTUAL ROUTING OF RACEWAYS, CABLE TYPES AND NUMBERS AND WIRING DIAGRAMS. J. INSTRUCTION DESCRIBE AND DEMONSTRATE ALL MAINTENANCE AND OPERATIONAL ASPECTS OF THE SYSTEM TO PERSONNEL SELECTED BY THE OWNER. t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com OF WAS NC' z w �203415� �GI STERN �Ssio ��� 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT E LECTRIKG�D�PARTMENT SPECIFICATIONS ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: NCA DRAWN BY: AD 1 2 3 4 5 7 1 8 9 1 10 11 SHEET NO E0m01 Y 1 1 2 1 3 4 5 1 6 1 7 1 8 1 9 1 10 tgb architects x 0 w 0 U a OVERALL ELECTRICAL PLAN LEVEL 1 1 /8" = 1'-0" C CE) t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (I Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com VY OF WAShr AI O ' 20341 O� �GI STVI �SSjONAL E��� 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/2,4 OV E RAL LiiY OF EDMONDS DEVELOPMENT E L E CT Rjr.AfPARPIT ,4N LEVEL 1 ISSUANCE No. I Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 NCA AD 2 3 4 5 6 7 8 10 SHEET NO EOmO2 1 2 3 4 5 6 7 8 10 Y nJ G m a 0 I I I I F, 0 I I i I II 0 L 1 J 1 1 I L 1 —1+ 7 /j� + ....... _ ++ + I I I�-+++ I I I I- + I I I I�-+++ I I I�+I I -+ I I I�+ ++ I I I+ ++ /6 I I I I I I I I j �i i+ i i i i i i i i i ii i+ i i i i i+ i i-+-i-++-+-i+++i+i+++- j rx /V 1 SUITE 100 LIGHTING DEMOLITION PLAN LEVEL 1 E 1.00 1 /4" = 1'-0" Notes # Note L:01 DISCONNECT EXISTING BRANCH CIRCUIT AND REMOVE LIGHT FIXTURE FOR REUSE. REFER TO SHEET E2.00 FOR ADDITIONAL INFORMATION tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com VY OF WAShr `� AI O ��20341 GI STER �SSjONAL E��� 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED SUITE IICIQ/8/24 L I G H T I N GY OF EDMONDS DEVELOPMENT D E M O L mnmR!'jT,4N LEVEL 1 ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: NCA DRAWN BY: AD N V 0 ai v N O N 2 3 4 5 6 7 8 9 10 SHEET NO El mOO 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 10 1 11 Y 3 c9 :T G a SUITE 100 ELECTRICAL DEMOLITION PLAN LEVEL 1 E 1.01 1 /4" = V-0" Notes # Note P:02 DEMOLISH RECEPTACLE. MAINTAIN BACK BOX AND CONDUIT FOR REUSE. P:05 DISCONNECT, TIE -BACK, AND MAINTAIN EXISTING BRANCH CIRCUIT AND DISCONNECT FOR REUSE. REFER TO SHEET E3.00 FOR EQUIPMENT RELOCATION. P:08 DISCONNECT, TIE -BACK, AND MAINTAIN EXISTING CONDUCTORS AND DEVICE FOR RELOCATION. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com VY OF WAShr AI O ' 20341 O� �GI STVI �SSjONAL E��� 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED SUITE 11001/8/24 ELECTriCONDS DEVELOPMENT D E M O L.mnmRPIT,4N LEVEL 1 ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 NCA AD 2 3 4 5 6 7 8 9 10 SHEET NO El mOl 1 1 2 I 3 1 4 I 5 1 6 I 7 1 8 I 9 10 11 Y 3 0 :T G U a 0 n 0 4 5 6 7 8 O r_ y 104 106 EXAM 1 105 EXAM j 1 107 ROOM#1 EXAM ROOM#3 EXAM 1 lnI ROOM #2 1 1 ROOM #4 Ir L:02 L:02 L:02 L:02 L:02 L:02 L:02 L:02 L:02 L:02 1 L4A 3 1 L4A-3 1 L4A 3 1 L4A 1 L4A 3 1 L4A 3 1 L4A 3 1 L4A 3 1 L4A 3 1 L4A 3 OS OS y OS OS OS OS 102 103 TOUCH TOUCH DOWN DOWN r - - - I r---1 r--- ir - - -i r---�r---1 r---ir---1 OFFICE #1 OFFICE #2 I I I I 1 11 1 1 I I I 1 11 I D D I II I D DI II I I II I D DI II I FPS LL � 110 CORRIDOR ®X01 OS e L01 L01 A L01 1 L4A-5 LL=7ml L4A-5,e 1 L4A-5,eLLL01 1 L4A-5,e 1 L4A-5,e o L03 1 L4A-5,e f TI ------------ ---- 11 li Ir- g D D [T 1 3,e 11 1 M I 101A I�1 L4A-5,g WORK ROOM OS OS r - - 1 L4A-3,a 1 L4A-3,a L01 1 O O O n 1 L4A-5,e L01 1 L:02 L:02 L:02 L:02 OS a D a -GM 1 L4A-5,f i 1 L4A i5 1 L4A-5 1 L4A-5 1 L4A-5 L03 O L-- -_ --J D,b�1 1L4A 5,g 1 D,c �1 L10 L10 L10 3,d'."' 111 112 101 lL4A-3,b lL4A-3,b lL4A-3,b 3,e r" 1 1 1OFFICE EXAM RECEPTION OS b,c e 109 MA/RN L11 L11 L11 �1 ® 1 L4A-3,Ci ® 1 L4A-3,c ® 1 L4A-3,c �L08� �L08� � L08 II 1 PH2A-28,c 1 PH2A-28,c 1 PH2A-28,C I 0 L03 0 L03 L01 1 L4A-3,d 1 L4A-3,d 1 L4A-5, I o L03 o L03 1 L4A-3,d 1 L4A-3,d I I II II - LL--jj -� o L03 OS d 0 L03 1 1 L4A-3,d 1 L4A-3,d II I I 1 -�i 100 ,��^ ILA- 1 o L03 ROOMO j' 0` L03 1 L4A-3,d i 1 L4 I I I I L10 I I I 1 1 L4A-3,b 0 L03 o L03 1 L4A-3,d 1 L4A-3,d L03 // ®X01 1�L4A-3,d / 1L4A 3 ` ' 0'',� �4 1 L4 ,��/ � 1 L4A-3,d - - 0 0L4A-3,d /F777 //1 SUITE 100 LIGHTING PLAN LEVEL 1 1 /4" = 1'-0" 11111111VWR� EXAM ROOM #11 r---� I I L:02 1L4A-5 OS r lei(Be L01 X02 74 1 L4A-5,e 1 L4A-5 LUMINAIRES ALTERNATE LAMP INPUT CONTROLS TYPE LUMENS CCT CRI (MIN) WATTS VOLTAGE TYPE RANGE TYPE DESCRIPTION MANUFACTURER CATALOGISERIES # MANUFACTURERS COMMENTSINOTES L01 2' X 4' LED TROFFER, WHITE REFLECTIVE HOUSING WITH CURVED ACRYLIC LENS LITHONIA BLT OR APPROVED EQUAL LED 3862 Im 3500 K 82 39 W 277 V 0-10V 1% PROVIDE 90 MINUTE BATTERY PACK FOR EM FIXTURES 3500K 5000LM L02 2' X 2' LED TROFFER, WHITE REFLECTIVE HOUSING WITH CURVED ACRYLIC LENS LITHONIA BLT OR APPROVED EQUAL LED 3047 Im 3500 K 82 31 W 277 V 0-10V 1% 3500K 5000LM L03 RECESSED 6" DOWNLIGHT, NOMINALLY 9" RECESS DEPTH, COLD ROLLED STEEL GOTHAM EVO OR APPROVED EQUAL LED 1380 Im 3500 K 90 9 W 277 V 0-10V 1% PROVIDE 90 MINUTE BATTERY PACK FOR EM FIXTURES HOUSING, SELF FLANGED, CLEAR, SEMI-SPECULAR ALZAK LOWER DONE REFLECTOR PROVIDES NIMINALLY 50 DEGREE CUTOFF TO IMAGE OF LENS. INTEGRAL LED DRIVER, STANDARD MANUFACTURER'S TRIM AS SELECTED BY ARCHITECT. L04 SURFACE WALL MOUNTED LED BACKLIT MIRROR 23-5/8W" X 35-3/8"H. BOBRICK B-167 2436 OR APPROVED EQUAL LED 2640 Im 3500 K 90 24 W 277 V 0-10V (none) L08 CIRCULAR PENDANT LIGHTING VISUAL MINA PENDANT NONE LED 167 Im 3500 K 90 9 W 120 V (none) (none) COMFORT L09 LED UNDERCABINET LIGHT WITH INTEGRAL ROCKER SWITCH, 24" LENGTH, LITHONIA UPLD CABINET LIGHT OR APPROVED EQUAL LED 997 Im 3500 K 96 11 W 120 V (none) (none) ALUMINUM HOUSING WITH WHITE FINISH, LINKABLE FOR CONTINUOUS LENGTHS, DIRECT WIRED. L10 COVE LIGHTING PRUDENTIAL LTG BionicPro4 OR APPROVED EQUAL LED 4605 Im 3500 K 90 31 W 277 V (none) (none) L11 4" RECESSED LINEAR SLOT PRUDENTIAL LTG BionicPro4 OR APPROVED EQUAL LED 2228 Im 3500 K 90 15 W 277 V 0-10V (none) X01 EXIT SIGN, WHITE HOUSING, CLEAR ACRYLIC PANEL WITH GREEN LETTERS, FIELD LITHONIA LRP OR APPROVED EQUAL LED 743 Im 3500 K 80 5 W 277 V (none) (none) CONFIG CHEVRONS, SINGLE FACED. X02 SAME AS X01 EXCEPT DOUBLE FACED. LITHONIA LRP OR APPROVED EQUAL LED 743 Im 3500 K 80 5 W 277 V none none A i L:02 I 1L4A-3,a L09 1 H2A-23,b • OS 108 1ET_P SOILED I b UTILITY I L09 I 1 PH2A-23,b I 1L4A-3,a I L0ro/ 9 a I 1 PH2A-23,b xx X02 /L01 �1L4A-5 1 L4A-5,e j j,I�h L01 I 1 L4A-5,h I Notes # Note L:02 REUSE EXISTING LIGHT FIXTURE AND CONNECT TO BRANCH CIRCUIT SHOWN. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com VY OF WAShr AI O 7' ' 20341 O� �GI STV, 1ST �SSjO 11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED _ 11/8/24_ S U I T E 1 04 OF EDMONDS DEVELOPMENT LIGHTI1, rCVIPA/.1 LEVEL 1 ISSUANCE No. I Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: NCA DRAWN BY: AD Ln 0 ai v N O N 2 3 4 5 6 7 8 9 10 SHEET NO E2mOO 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 10 1 11 Y 3 c7 IL nJ G U a Notes # Note IP:01 PROVIDE CONTROLLED RECEPTACLES VIA POWER PACKS AND OCCUPANCY SENSOR. REFER TO LIGHTING PLANS FOR OCCUPANCY SENSOR. PROVIDE MARKING TO IDENTIFY CONTROLLED RECEPTACLES. P:03 REUSE EXISTING BACK BOX AND CONDUIT FOR NEW RECEPTACLE AND BRANCH CIRCUIT. P:04 PROVIDE PATHWAY FROM BASEMENT OF TO ACCESSIBLE CEILING OF LEVEL 1. REFER TO SHEET E5-01 FOR ADDITIONAL INFORMATION. 4 5 6 7 8 P:06 EXTEND EXISTING BRANCH CIRCUIT AND CONNECT TO RELOCATED EQUIPMENT. P:07 PROVIDE NURSE CALL POWER SUPPLY. POWER SUPPLY CONNECTS TO STAFF ASSIST BUTTONS IN EXAM ROOMS. P:09 EXTEND EXISTING CONDUCTORS AND CONNECT TO RELOCATED DEVICE. I I F--� 1111�MMA (D 1 D4A-37,39,41 1 PH2A-7 l PHPH2A-7 1 PH2A-5�1 PH2A-5 1 PH2A-3VPH2A-3 /o/ SUITE 100 ELECTRICAL PLAN LEVEL 1 1 /4" = 1'-0" tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com OF WA Sh,I P:09AI 61 1OAF OP 110 OP j Zp 30AS CORRIDOR j ®VAV-1-5 A 1 PI2A-26 j �� 20341 � 1 D4A-37,39,41 1 PH2A-26 GI E������ M�i G sjG G 11/8/2024 1PH2A-35 Ivl 1PH2A-35 ICI-1PH2A-2 p / 1 PH2A-25 114 �hH2A8 UUU 1 PH2A-2 EXAM t1 PH2A-8 j ROOM P 1 PH2A-33 i 3/4"C-2# 12 3/4"C-2# 12 3/4"C-2# 12 / 1 PH2A-331 111 1 PH2A-33 1 PH2A-35 �I 1 PH2A-35 1 PI-2 1 PH2A 26 j OFFICI 15AF j IIIIi - �II - J EXAM EXAM 20AS J p 119 MA/RN D, PRINTER 1 � 10AF ROOM#5 ROOM#6 1D4A- 31 HALLWAY MA RN 1 PH2A-31 30AS 1 D4A 20,22,24 ,1�PH2A 10 1 PH2A-28 0 �, VAV 1 12 1 PH2A-32 1 PH2A-35 1 PH2A-32 1 PH2A-35 1 PH2A-32 1 PH2A-2 �1 PH2A-10 q 1 D4A 37,39,41 ern L -- f 7� 1"C-3#6, 1#10G OP 1 PH2A-6 1 PH2A-34 1 PH2A-4 1 PH2A-34 1 PI-4 1 PI-34 1 PH2A-2 1 PH2A-34 p ,1tPH2 -12 / � I Ij - c1 PH2A-12 1PH2� 7 I I _ _ 1 PH2A-4 1 PH2A-4 1 PH2A-2 1PH2A-27 1PH2A-6 115 — J 3l4"C-2#12 116 3/4"C-2#12 117 3/4"C-2#12 118 3l4"C-2#12 1PH2A-26 j EXAM EXAM EXAM EXAM j ` ' ROOM #11 ` ' ROOM #10 ` ROOM #9 1 ' ROOM #8 p / f�l `1PH2A-14 SWEDISH EDMONDS 1M21 9 F [l PH2A 14 MEDICAL PAVILION 1 PH2A-29 1 PH2A-6 1 PH2A-4[01 1 PH2A-4 LD 1 PH2A-2 _.—._ V G •- G G G u X LEVEL 1 �I" 120 1"C-3#6, 1#10G 1 PI2A-24 CORRIDOR 15AF P B„ 20AS J O i D4A-20,22,24 OP 1 D4A-20,22,24 O j 1 PI2A-24 j 1PH2A 24 7320 216TH STREET SUITE 100 I EDMONDS, WA 98026 1 PH2A-20 1 PH2A-20 1 PH2A-18 I I 1 PH2A-16 j ------------� r--- JL — — —U L---JL--- / NURSE CALL POWER SUPPLY �i 122 123 ® 1 PH2A-22G I TOILET#1 I I TOILET#2I G R P:07 1 PH2A-24 1 PH2A-24 1 PH2A-18 1 PH2A-18 1 PH2A-16 I 1PH2A 16PH2A 16 j 1 PI2A-20 I I i t I 1 PH2A-18 121 I iiift i CLEAN j --- __� ----- L-- — --J / PERMIT/BID SET UTILITY III III 124 125 III III j SCHEDULER SCHEDULER j RECEIVED 1 PI-20 c 11/8/24 SUITE I VAk OF EDMONDS DEVELOPMENT E L E C T RIIOAfPARPIT AN LEVEL 1 ISSUANCE No. I Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: 24034 PROJECT LEAD: NCA DRAWN BY: AD 0 ai v N O N 2 4 1 5 1 6 1 7 1 8 9 10 SHEET NO E3mOO 1 1 2 3 1 4 5 1 6 7 1 8 9 1 10 11 Y tgb architects x (D U- PANEL AFFECTEI BY THIS PROJEC W 111d"(_/dlff3RfA(; 44YVr1A�41ni QMcni SECOND FLOOR t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 I stantec.com OF WA �203415� fir( tGI STERN' 15� �SSIONAL �11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET FIRST FLOOR RECEIVED Q CD w 11/8/24 T BSW2A ¢ Q ¢ Q Q o 0 30 KVA w N M oOf z CITY OF EDMONDS 480- 208YI120V = CIOC DEVELOPMENT PANEL 3112"C-(4)#750KCMILAL z cis z z z z w w ¢ SERVICES DEPARTMENT BSW2A & #310 G AL " 0 0 0 0 0 0 C� oU- o> 11/4C.O. 208YI120V ~ ~ ~ ~ ~ ~ ~ `/' ~ `"' ~ " M 13-TERMINAL ELECTRICAL RISER 100A MLO METER i 20AF i 20AF i 35AF SOCKET U a 0 75 K PANEL PANEL 480 P2A P2 3� 2112"C-4#250KCMIL AL ZSUUA,46UYl2/IV,JF',4VV PARTIAL ELECTRICAL RISER BASEMENT ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 NCA AD a CD 0 M v (V O N 1 2 3 4 5 1 6 7 8 10 11 SHEET NO E4mOO R� 1 1 2 3 1 4 5 1 6 7 1 8 9 1 10 11 tgb architects x cD W 0 U a (1)4"C TO CABLE TV UTILITY (1)4"C TO TELEPHONE UTILITY (1)4"C TO 44' VAULT SE OF BLDG, CONNECTS TO IMAGING AND ONCOLOGY (2)2"C SLEEVES - CAPPED orrGcciRi G rGu rnir_ H ZiZ�r THIRD FLOOR FIRST FLOOR TO SWEDISH SUITE 30 WORK COVERED BY A SEPARATE PROJECT. I I BASEMENT TELECOM RISER t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-0555 1 stantec.com OF WA �203415� ,,, -tGI STERN �SSIONAL �11 /8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TELECOM RISER ISSUANCE No. Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: 24034 NCA AD a CD 0 v (V O N 1 2 3 4 5 6 7 8 7 10 11 SHEET NO E5mOO 0. 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 tgb architects t> LL W C3 U Stantec Name: Location: Serves: 1PH2A 120/208V 1ST FLOOR MAIN ELECT ROOM 30 4W 150A Main CB Surface Mounted Single Lugs Panel Type: Panelboard 0 AIC Deep # Description Load CB * A B C CB * Load Description # 1 Recept WAITING ROOM 100 0.72 20/1 CB 20/1 CB 1.08 Recept EXAM ROOMS 118,114 2 3 Recept RECEPTION 101 0.54 20/1 CB 20/1 CB 1.08 Recept EXAM ROOMS 116,117 4 5 Recept RECEPTION 101 0.54 20/1 CB 20/1 CB 0.54 Recept EXAM ROOM #11115 6 7 Recept RECEPTION 101 0.54 20/1 CB 20/1 CB 0.54 Recept EAST NURSE STATION 8 9 Equip PRINTER WORK ROOM 101A 1.00 20/1 CB 20/1 CB 0.54 Recept EAST NURSE STATION 10 11 Recept TOUCH DOWN OFFICE #1 102 0.72 20/1 CB 20/1 CB 0.54 Recept EAST NURSE STATION 12 13 Recept TOUCH DOWN OFFICE #1102 0.72 20/1 CB 20/1 CB 0.54 Recept EAST NURSE STATION 14 15 Recept TOUCH DOWN OFFICE #2103 0.72 20/1 CB 20/1 CB 0.90 Recept SCHEDULER 125 16 17 Recept TOUCH DOWN OFFICE #2103 0.72 20/1 CB 20/1 CB 0.90 Recept SCHEDULER 124 18 19 Recept EXAM ROOMS 105,104 1.08 20/1 CB 20/1 CB 0.72 Recept CLEAN UTILITY 121 20 21 Recept EXAM ROOMS 106,107 1.08 20/1 CB 20/1 CB 0.36 Equip NURSE CALL PS 22 23 <Multi> RECEPT AND U/G LTG SOILED UTILITY 108 0.75 20/1 CB 20/1 CB 0.90 Recept SOUTH CORRIDOR AND TOILETS 24 25 Recept EAST NURES STATION 0.54 20/1 CB 20/1 CB 0.90 Recept NORTH AND EAST CORRIDORS 26 27 Recept EAST NURES STATION 0.54 20/1 CB 20/1 CB 0.97 <Multi> RECEPTION RECEPTACLES AND DECORATIVE LTG 28 29 Recept EAST NURES STATION 0.54 20/1 CB 20/1 CB 0,72 Recept EXAM ROOMS 104,105,107 CHAIRS 30 31 Equip PRINTER EAST NURES STATION 0.50 20/1 CB 20/1 CB 0.54 Recept EXAM ROOMS 114,113,112 CHAIRS 32 33 Recept OFFICE 111 0.72 20/1 CB 20/1 CB 0.72 Recept EXAM ROOMS 116,115,117,118 CHAIRS 34 35 Recept EXAM ROOMS 113,112 1.08 20/1 CB 20/1 CB 1.50 Equip FIREPLACE 36 37t Recept 0.36 0/1 CB 0/1 0.00 Spare 38 39t <Multi> 1.30 20/1 CB 0/1 0.00 Spare 40 41t Recept PHARM PLUG MOLD 1.00 20/1 CB 0/1 0.00 Spare 42 Rev: Revised circuits marked $ Existing circuits marked t Project #: File: R:\client\Swedish Medical Center\ Edmonds\ Edmonds Medical Pavilion\ WinPanel\EDM Medical Pavilion Panel Schedules.PNL fdA OJB p}C * Circuit Breaker Code G = GFCI H= HID Rated S =Shunt Trip C =HACK Rated D= Switching Duty # = see note A = AFCI Connected KVA 8.78 10.07 1 10.45 Notes: EXISTING PANEL Load Type Conn KVA NEC Demand Factor Demand KVA Demand Amps NEC Feeder Factors NEC Feed Amps Lighting Recept Equip 0.36 x 100% 24.58 10 KVA @ 100%, rest @ 50% 4.36 x 100% 0.36 17.29 4.36 1 48 12 x 125% x 100% x 100% 1 48 12 29.30 81 Amps 22.01 61 61 Stantec Name: Location: Serves: 114A 277/480V 1ST FLOOR MAIN ELECT ROOM 30 4W 100A Main lugs only Surface Mounted Single Lugs Panel Type: Panelboard 0 AIC Deep # Description Load CB * A B C CB * Load Description # 1 Lighting SUITE 10 [EBRL] [NOTE 11 1.12 20/1 CB 20/1 CB 4.43 Lighting WOMEN'S CENTER 2t 3 Lighting SUITE 100 [EBRL] [NOTE 11 1.27 20/1 CB 20/1 CB 4.43 Lighting WOMEN'S CENTER 4t 5 Lighting SUITE 100 [EBRL] [NOTE 1] 0.76 20/1 CB • 20/1 CB 4.43 Lighting WOMEN'S CENTER 6t 7t Lighting UNK 4.43 20/1 CB 20/1 CB 4.43 Lighting BLOOD DRAW 8t 9t Lighting UNK 4.43 20/1 CB 20/1 0.00 Spare 10 11 Spare 0.00 0/1 20/1 0.00 Spare 12 13 Space 0.00 0/1 0/1 0.00 Space 14 15 Space 0.00 0/1 0/1 0.00 Space 16 17 Space 0.00 0/1 0/1 0.00 Space 18 19 Space 0.00 0/1 0/1 0.00 Space 20 21 Space 0.00 0/1 0/1 0.00 Space 22 23 Space 0.00 0/1 0/1 0.00 Space 24 25 Space 0.00 0/1 0/1 0.00 Space 26 27 Space 0.00 0/1 0/1 0.00 Space 28 29 Space 0.00 0/1 0/1 0.00 Space 30 31 Space 0.00 0/1 0/1 0.00 Space 32 33 Space 0.00 0/1 0/1 0.00 Space 34 35 Space 0.00 0/1 0/1 0.00 Space 36 37 Space 0.00 0/1 0/1 0.00 Space 38 39 Space 0.00 0/1 0/1 0.00 Space 40 41 Space 0.00 0/1 0/1 0.00 Space 42 Rev: Revised circuits marked $ Existing circuits marked ked t Project #: File: R:\client\Swedish Medical Center\ Edmonds\ Edmonds Medical Pavilion\ WinPanel\EDM Medical Pavilion Panel Schedules.PNL 0g 0C * Circuit Breaker Code G = GFCI H= HID Rated S =Shunt Trip C =HACK Rated D= Switching Duty # = see note A = AFCI KVA 1 4.4 10. 14 5.19 Notes: EXISTING PANEL; [EBRL] EXISTING BREAKER, REVISED LOAD; [NOTE 11 BRANCH CIRCUIT REVISED AS PART OF SUITE 10 TI PROJECT Load Type Conn KVA NEC Demand Factor Demand KVA Demand Amps NEC Feeder Factors NEC Feed Amps Lighting 29.73 x 100% 29.75 36 x 125% 45 29.75 36 Amps 29.75 36 45 ShPnl3ph.rpt R:\client\Swedish Medical Center\Edmonds\Edmonds Medical Pav 11/8/2024 Stantec Name: Location: Serves: 1134A 277/480V 1ST FLOOR MAIN ELECT ROOM 30 4W 400A Main lugs only Surface Mounted Single Lugs Panel Type: Panelboard 0 AIC Deep # Description Load CB * A B C CB * Load Description # It PanelIPH2A 8.78 70/3 CB 175/3 CB 0.00 PanelIWC2A-1 2t 3t 1PH2A 10.07 ------- --- ------- --- 0.00 -------1WC2A-1 4t 5t -1PH2A 10.45 ------- --- ------- --- 0.00 -------1WC2A-1 6t 7t X-Ray X-RAY RADIOGRAPHIC GENERATOR 16.67 100/3 CB 100/3 CB 14.42 Panel IL4A 8t 9t -X-RAY RADIOGRAPHIC GENERATOR 16.67 ------- --- ------- --- 10.14 -------1L4A 10t lit -X-RAY RADIOGRAPHIC GENERATOR 16.67 ------- --- ------- --- 5.19 -------1L4A 12t 13 Space 0.00 0/1 0/1 0.00 Space 14 15 Space 0.00 0/1 0/1 0.00 Space 16 17 Space 0.00 0/1 0/1 0.00 Space 18 19t Mech VAV 1-1 THRU 13,1-8 THRU 1-10 11.33 60/3 CB 60/3 CB 1.07 Mech VAV 1-31,1-32 [NBNL] 20 21t -VAV 1-1 THRU 1-3,1-8 THRU 1-10 11.33 ------- --- ------- --- 1.07 -------VAV 1-31,1-32 [NBNL] 22 23t -VAV 1-1 THRU 1-3,1-8 THRU 1-10 11.33 ------- --- ------- --- 1.07 -------VAV 1-31,1-32 [NBNL] 24 25t Mech ECH3 CABINET HEATER 1.67 20/3 CB 20/3 CB 1.67 Mech ECH-1 CABINET HEATER 26t 27t ----ECH3 CABINET HEATER 1.67 ------- --- ------- 1.67 -------ECH-1 CABINET HEATER 28t 29t -----ECH3 CABINET HEATER 1.67 ------- --- ------- --- 1.67 -------ECH-1 CABINET HEATER 30t 31t Mech ECH-2 CABINET HEATER 1.67 20/3 CB 60/3 CB 12.70 Mech AC-3 32t 33t ----ECH-2 CABINET HEATER 1.67 ------- --- ------- --- 12.70 -------AC-3 34t 35t ----ECH-2 CABINET HEATER 1.67 ------- --- ------- --- 12.70 -------AC-3 36t 37t Mech VAV 1-4 THRU 7,1-11,1-12,1-14 11.03 60/3 CB 60/3 CB 4.13 Mech VAV 1-26 THRU 29 38t 39t -VAV 1-4 THRU 7,1-11,1-12,1-14 11.03 ------- --- ------- --- 4.13 -------VAV 1-26 THRU 29 40t 41t -VAV 1-4 THRU 7,1-11,1-12,1-14 11.03 ------- --- ------- --- 4.13 -------VAV 1-26 THRU 29 42t Rev: Revised circuits marked I Existing circuits marked t Project #: File: R:\client\Swedish Medical Center\ Edmonds\ Edmonds Medical Pavilion\WinPanel\EDM Medical Pavilion Panel Schedules.PNL OA 0B OC * Circuit Breaker Code G = GFCI H= HID Rated S =Shunt Trip C = HACR Rated D= Switching Duty # = see note A = AFCI Connected KVA 85.13 1 82.14 1 77.58 Notes: EXISTING PANEL; 600A FRAME; [NBNL] NEW BREAKER, NEW LOAD Load Type Conn KVA NEC Demand Factor Demand KVA Demand Amps NEC Feeder Factors NEC Feed Amps Lighting 3.22 x 100% Recept 23.22 10 KVA @ 100%, rest @ 50 % Equip 3.36 x 100% Mech 3.20 x 100% Recorded Demand * 50.78 x 125% * Recorded Demand calculated as 50.78kVA x 100% S.A.F. x 100% O.A.F. 3.22 16.61 3.36 3.20 63.48 4 20 4 4 76 x 125% x 100% x 100% 125% of Largest x 100% 5 20 4 5 76 83.78 101 Amps 89.86 108 110 ShPn]3ph.rpt R:\client\Swedish Medical Center\Edmonds\Edmonds Medical Pav 11/8/2024 Stantec Swbd Name: MDP 277/480V 30 4W 2,500A Main CB Type: Switchboard Location: BASEMENT MAIN ELECTRICAL ROOM Surface Mounted 0 AIC Serves: Single Lugs Deep Overcurrent device Size * Type # Description Load Remarks 1 Space 0.00 KVA OA/1P 2 Panel BD4A 149.90 KVA 40OA/3P CB 3 Panel lD4A 244.85 KVA 40OA/3P CB 4 Panel2D4A 163.57 KVA 40OA/3P CB 5 Panel EDST 0.00 KVA 25OA/3P CB 6 Panel1E4A 0.00 KVA 10OA/3P CB 7 Panel1SC4A 0.00 KVA 60OA/3P CB 8 Panel3X4A 0.00 KVA 25OA/3P CB 9 Panel3D4A 0.00 KVA 40OA/3P CB 10 Panel RM4A 0.00 KVA 600A/3P CB Rev: * Circuit Breaker Code Revised circuits marked $ Existing circuits marked t CB = Circuit Breaker S = Shunt Trip Project #: G = GFCI M = Motor Ckt Prot. H= HID Rated F = Fused Switch File: R:\client\Swedish Medical C = HACR Rated # =see note Center\Edmonds\Edmonds Medical Pavilion\ WinPanel\EDM Medical Pavilion Panel Schedules.PNL Notes: EXISTING PANEL Load Type Conn KVA NEC Demand Factor Demand KVA Demand Amps NEC Feeder Factors NEC Feed Amps Equip 20.55 x 100% 20.55 25 x 100% 25 Lighting 4.45 x 100% 4.45 5 x 125% 7 Mech 80.99 x 100% 80.99 97 125% of Largest 106 Recept 41.49 10 KVA @ 100%, rest @ 50% 25.75 31 x 100% 31 Recorded Demand * 403.60 x 125% 504.50 607 x 100% 607 * Recorded Demand calculated as 403.6OkVA x 100% S.A.F. x 100% O.A.F. 551.09 663 Amps 636.24 765 775 t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com (3 Stantec Stantec Consulting Services Inc. 3400188th St SW Suite 285 Lynnwood, WA 98037-4772 Tel: (206) 667-05551 stantec.com VY OF WAhr t✓� AI O 20341 O� �GIST ER �SSIONAL 11/8/2024 SWEDISH EDMONDS MEDICAL PAVILION LEVEL 1 7320 216TH STREET SUITE 100 EDMONDS, WA 98026 PERMIT/BID SET RECEIVED 11/8/24 CITY OF EDMONDS DEVELOPMENT PANEL SERVICES DEPARTMENT SCHEDULES 155UANUF- No. I Description Date PERMIT SET 11/08/24 PROJECT INFORMATION PROJECT NUMBER: PROJECT LEAD: DRAWN BY: a ShPnl3ph.rpt ShSwbd.rpt R:\client\Swedish Medical Center\Edmonds\Edmonds 11/8/2024 Q R:\client\Swedish Medical Center\Edmonds\Edmonds 11/8/2024 Medical Pav v Medical Pav N o SHEET NO v N O N E6mOO 24034 NCA AD 1 1 2 3 1 4 1 5 6 7 8 9 10 11