Loading...
REVIEWED BLD2024-1478+WA_State_Energy_Compliance_Form+11.8.2024_4.06.47_PM+461083911/7/24, 9:26 PM waenergycodes.com/print_project_summary_ form. php?k=aWQ9Mjk5ODAmZnZpPTIzJ nJIc2V0PTE=&debug=1 LIGHTING COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project Title Edmonds Medical Pavilion - Suite 100 TI - 2021 WSEC For Building V E D Date: Nov 08 2024 �+ �' v ProjectAddress 7320 216th Street . ............................................. Suite 100 REVIBE ED 11 /8/24 Project & Applicant Edmonds, WA 98026 CITY OF MONDS Information BLD2024-1 478 Applicant Name Nowell Ancheta BUILDING DEPARTMENT: ,,,,,,,,,,,,,,,NT: ' CITY OF EDMONDS DEVELOPMENT Applicant Phone 206-667-0566 SERVICES DEPARTMENT Applicant Email nowell.ancheta@stantec.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 80,000 New Building or Project Cond. Floor Area 15,572 Floors Above Grade 3 General Project Types Alteration Addition AlterationLihflng Scope g Interior Lighting Compliance Method General Prescriptive Lighting Scope Lighting Project Description This project builds out a Clinic on Level 1. Lighting Compliance Project Type Interior / Exterior (interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope & parking) Adjustment Verification and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Energy Efficiency (AEC) No lighting or electrical additional energy efficiency Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included measures included in project rojec itic Edmonds Medical Pavilion - Suite 100 TI - 2021 WSEC a e I Nurvu—,z Lighting Power Calculation ALTERATION -INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Corridors General 1,000 0.41 410 Office Enclosed < 250 sf 883 0.74 653 Restroom General 140 0.63 88 Seating area 1 1 835 1 0.23 192 Healthcare facility Exam/treatment room 1,250 1.40 1,750 Healthcare facility Medical supply room 290 0.62 180 Proposed Total LPD 2,346 Totals 3,274 2,346 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant L08 3 9 27 Troffer LOl 49 39 1,911 Troffer L02 1 2 1 31 62 Recessed downlight L03 1 15 1 9 135 https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjk5ODAmZnZpPTIzJnJIc2VOPTE=&debug=1 1/2 11/7/24, 9:26 PM waenergycodes.com/print_ project_summary_form. php?k=aWQ9Mjk50DAmZnZpPTIzJ nJIc2VOPTE=&debug=1 Under -cabinet L09 3 11 33 Other fixture type X01/X02 5 5 25 Other fixture type 1,11 3 15 45 Other fixture type L10 4 15 60 Other fixture type L04 2 24 48 Proposed Total LPD 2,346 Project Tit Edmonds Medical Pavilion - Suite 100 TI - 2021 WSEC Nov 08, 2024 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) ::AW Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Direct / indirect pendant L08 E2.00 LED New Fixture Description: Pendant Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer LOl T E2.00 LED New Fixture Description: 2x4 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer L02 I E2.00 LED New Fixture Description: 2x2 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight L03 I E2.00 LED New Fixture Description: Downlight Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Under -cabinet L09 I E2.00 LED New Fixture Description: Under Cabinet Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type X01/X02 T E2.00 LED New Fixture Description: Exit Sign Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type Lit T E2.00 LED New Fixture Description: Linear Slot Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type L 10 I E2.00 LED New Fixture Description: Cove Lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type L04 I E2.00 LED New Fixture Description: Vanity Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjk5ODAmZnZpPTIzJnJIc2VOPTE=&debug=1 2/2