Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2024-1479+WA_State_Energy_Compliance_Form+11.8.2024_4.08.11_PM+4610855
11/7/24, 9:31 PM waenergycodes.com/print_project_summary_ form. php?k=aWQ9Mjk50DEmZnZpPTIzJ nJIc2V0PTE=&debug=1 LIGHTING COMPLIANCE SUMMARY 2021 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project Title Edmonds Medical Pavilion - Suite 220 TI - 2021 WSEC For Building Department Use: RECEIVED Date' NOV 08, 2024 REVIEWED 11 /8/24 Project Address 7320 216th Street Suite 220 Project & Applicant Information Edmonds, WA 98026 BY TY OF EDMONDS BLD2024-1479 PMONDS CITY DEVELOPMENT OPMENT SERVICES DEPARTMENT Applicant Name Nowell Ancheta Applicant Phone 206-667-0566 Applicant Email nowell.ancheta@stantec.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 80,000 New Building or Project Cond. Floor Area 1,298 Floors Above Grade 3 General Project Types Alteration Addition AlterationLihflng Scope g Interior Lighting Compliance Method General Prescriptive Lighting Scope Lighting Project Description This project builds out office on Level 2 Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope & parking) Adjustment Verification and Method Alteration Interior Lighting 20% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Energy Efficiency (AEC) No lighting or electrical additional energy efficiency Load Management (LDM) Measures Included No lighting or electrical load management measures included in project Measures Included measures included in project rojec itic Edmonds Medical Pavilion - Suite 220 TI - 2021 WSEC a e I Nurvu—,z Lighting Power Calculation ALTERATION -INTERIOR LIGHTING (20% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Corridors General 325 0.41 133 Lounge/breakroom General 110 0.59 65 Office Enclosed < 250 sf 1,000 0.74 740 Proposed Total LPD 732 Totalsl 938 732 1 COMPLIES Proposed Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Troffer L02 6 31 186 Troffer Lot 1 14 1 39 1 546 Proposed Total LPD 1 732 Project Title Edmonds Medical Pavilion - Suite 220 TI - 2021 WSEC Date Nov 08, 2024 https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjk5ODEmZnZpPTIzJnJIc2VOPTE=&debug=1 1/2 11/7/24, 9:31 PM waenergycodes.com/print_project_summary_form. php?k=aWQ9Mjk5ODEmZnZpPTIzJ nJIc2VOPTE=&debug=1 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (20% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer L02 E2.00 LED New Fixture Description: 2x2 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer I LOl T E2.00 LED New Fixture Description: 2x4 LED Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9Mjk5ODEmZnZpPTIzJnJIc2VOPTE=&debug=1 2/2