APPROVED BLD BLD2025-0029+Architectural_Plan+1.9.2025_7.56.12_AM+4703252ZUZI taition
Remodel / Alteration Worksheet
Will you be exposing the walls? Will the roof/ceiling framing cavities or attic be exposed? Will the will the floor framing cavities be exposed?
xI Yes x No h Yes x No
If yes, If yes, If yes,
❑ 2 X 4 wall studs require R-15 insulation Exposed roof or ceiling assemblies must be insulated - ❑ Exposed floor cavities must be insulated to R-30
❑ 2 X 6 wall studs require R-21 insulation Vaulted ceilings, Insulate to the full depth of the
framing member
If siding is replaced C.I. equal to R-5 may need installed Flat ceilings, install R-60 insulation or what the
under the siding. attic space can accommodate based on the roof
pitch
Are the windows and/or doors being replaced? Will the heating or cooling system be replaced? Will the hot water system be altered? Are more than 10% of the light fixtures beingchanged?
Yes No x x Yes x No
If yes,
❑New windows and doors (+frames) must
have an area weighted average U-factor of
<_0.30
If yes,
New equipment must meet current ❑
requirements and the ducts need to be
tested
If yes,
ElNew water heating equipment must
meet current code requirements
1
OBTAIN A SEPARATE •.
PLUMBING PERMIT
FROM THE CITY OF
• EDMONDS.
.......................................7
1 ■
WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1
TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO j
1 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED.
1 1
REFER TO 2021 IRC R314 AND R315 FOR MORE 1
INFORMATION. j
1
1
1 STRUCTURAL REPAIR IS NOT INCLUDED IN THE SCOPE FOR THIS PERMIT.
IF IT IS FOUND THAT STRUCTURAL REPAIRS ARE NEEDED A SEPARATE 1
1 PERMIT MUST BE SUBMITTED TO THE CITY FOR APPROVAL, AND PLANS
MUST BE STAMPED AND SIGNED BY THE ENGINEER OF RECORD. 1
1
If yes,
❑ 100% of all lamps must be high
efficacy
1
OBTAIN ELECTRICAL •.
PERMIT FROM IN
STATE LABOR &
•. INDUSTRIES
1
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
1. PARCEL NUMBER: 00434207000800 '
2. VICINITY MAP (SEE THIS PAGE).
3. NEW CONSTRUCTION: 924 MAPLE ST. EDMOMDS, WA. 98020
4. OWNERKATHY CHROSTOWSKA & PATRICK FELDMAN
5. LEAD DESIGN PROFESSIONALCONTACT PERSON: REGGIE BRUCE 425-772-0646
6. EXISTING BASEMENT FLOOR = EX. LIV: 779.32 SQ. FT., EX. CARPORT 861.00 SQ. FT. UNHEATED STORAGE 140.00 SQ. FT.
7. OCCUPANCY: GROUP R, DIVISION 3.
8. THIS BUILDING IS TYPE VB.
Playfie/d
z
ai
Q
Bell St.
n
Main St.
Maple St.
Alder St.
Beck Ln.
Holly Dr.
Walnut St.
Hemlock Wy.
Edmonds
Park and
RecreaEion
O
Maple St
V)
Bell St
Main St.
� Alder St
Q
L
Cedar St.
Spruce St.
Ln
City Of Edmonds
Building Department
Work REMODEL
Address 924 MAPLE
Owner CHROSTOWSKA
Approved Date 01 /23/2025
Building Official wwv'ta
-----------------------
----------------------
Permit Number
BLD2025-0029
9. GLAZING U VALUE VERTICAL = .30U VALUE OR BETTER, OVERHEAD U VALUE =.50,
CEILING R VALUE=R-49, WALL R VALUE=21, FLOOR INSUATION R-30, SLAB R VALUE=R-10
10. COMPLY WITH IBC 2021', IRC 2021', IMC 2021', IFC 2021', UPC 2021, WSEC 2021.
11. ADDRESS NUMBERS (6" HEIGHT ON APPR. CONTRASTING BACKGROUND) SHALL BE POSTED PLAINLY VISIBLE & LEGIBLE FROM STREET OR
ROAD FRONTING PROPERTY.
12. PROVIDE FIRE ESTINGUISHERS PER IFC STANDARD 10-1.
Ln
Hemlock St. Q
L
L
FA
Val
v
Q
L
rn
Walnut St.
D
rD
in
TABLE OF.
CONTENTS
COVER SHEET:
Pi VICINITY MAP, PROJECT INFO.,
ENERGY WORKSHEETS
ARCHITECTURAL:
Al EX. BASEMENT FLOOR PLAN
A2 REMO BASEMENT FLOOR PLAN
5YM50L5
INDICATE5 EXI5TING EXTERIOR WALL
INDICATE5 EX. FOUNDATION WALL
0 INDICATE5 EXI5TING INTERIOR WALL
o INDICATE5 NEW 2X4 @ 16" O.C.
INDICATE5 WALL TO BE REMOVED
INDICATE5 NEW 2X6 @ 16" O.C. STUD
WALL W/ R-21 (EXT TYPE)
O 120V 5MK PET W/BATT BACKUP
CARBON MONOXIDE DETECTOR
PER IRC 515
CFM FAN COMPLY WITH M1507, 2015 IRC
EX. BASEMENT -
FLOOR PLAN
5CALE:1/4" = 1'-O"
EX. LIVING: 779.32 5Q. FT.
EX. EXTERIOR 5TORAGE:140.00 5Q. FT.
EX. CARPORT: 561.00 5Q. FT.
5YM50L5
INPICATE5 EXI5TING EXTERIOR WALL
IN[)ICATE5 EX. FOUNDATION WALL
0 INPICATE5 EXI5TING INTERIOR WALL
o INPICATE5 NEW 2X4 @ 16" O.C.
INPICATE5 WALL TO BE REMOVE[)
INPICATE5 NEW 2X6 @ 16" O.C. 5TUP
WALL W/ R-21 (EXT TYPE)
O 120V 51VIK PET W/BATT BACKUP
CARBON MONOXIDE DETECTOR
PER IRC 515
CFM FAN COMPLY WITH M1507, 2015 IRC
PROVIDE EXHAUST
FAN W/ 50CFM MIN
VENTED TO OUTSIDE
FLOOR PLAN
5CALE:1/4" = 1'-O"
NO CHANGE TO 50. FT.