APPROVED BLD BLD2025-0029+Architectural_Plan+1.9.2025_7.56.12_AM+4703252ZUZI taition Remodel / Alteration Worksheet Will you be exposing the walls? Will the roof/ceiling framing cavities or attic be exposed? Will the will the floor framing cavities be exposed? xI Yes x No h Yes x No If yes, If yes, If yes, ❑ 2 X 4 wall studs require R-15 insulation Exposed roof or ceiling assemblies must be insulated - ❑ Exposed floor cavities must be insulated to R-30 ❑ 2 X 6 wall studs require R-21 insulation Vaulted ceilings, Insulate to the full depth of the framing member If siding is replaced C.I. equal to R-5 may need installed Flat ceilings, install R-60 insulation or what the under the siding. attic space can accommodate based on the roof pitch Are the windows and/or doors being replaced? Will the heating or cooling system be replaced? Will the hot water system be altered? Are more than 10% of the light fixtures beingchanged? Yes No x x Yes x No If yes, ❑New windows and doors (+frames) must have an area weighted average U-factor of <_0.30 If yes, New equipment must meet current ❑ requirements and the ducts need to be tested If yes, ElNew water heating equipment must meet current code requirements 1 OBTAIN A SEPARATE •. PLUMBING PERMIT FROM THE CITY OF • EDMONDS. .......................................7 1 ■ WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO j 1 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. 1 1 REFER TO 2021 IRC R314 AND R315 FOR MORE 1 INFORMATION. j 1 1 1 STRUCTURAL REPAIR IS NOT INCLUDED IN THE SCOPE FOR THIS PERMIT. IF IT IS FOUND THAT STRUCTURAL REPAIRS ARE NEEDED A SEPARATE 1 1 PERMIT MUST BE SUBMITTED TO THE CITY FOR APPROVAL, AND PLANS MUST BE STAMPED AND SIGNED BY THE ENGINEER OF RECORD. 1 1 If yes, ❑ 100% of all lamps must be high efficacy 1 OBTAIN ELECTRICAL •. PERMIT FROM IN STATE LABOR & •. INDUSTRIES 1 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE 1. PARCEL NUMBER: 00434207000800 ' 2. VICINITY MAP (SEE THIS PAGE). 3. NEW CONSTRUCTION: 924 MAPLE ST. EDMOMDS, WA. 98020 4. OWNERKATHY CHROSTOWSKA & PATRICK FELDMAN 5. LEAD DESIGN PROFESSIONALCONTACT PERSON: REGGIE BRUCE 425-772-0646 6. EXISTING BASEMENT FLOOR = EX. LIV: 779.32 SQ. FT., EX. CARPORT 861.00 SQ. FT. UNHEATED STORAGE 140.00 SQ. FT. 7. OCCUPANCY: GROUP R, DIVISION 3. 8. THIS BUILDING IS TYPE VB. Playfie/d z ai Q Bell St. n Main St. Maple St. Alder St. Beck Ln. Holly Dr. Walnut St. Hemlock Wy. Edmonds Park and RecreaEion O Maple St V) Bell St Main St. � Alder St Q L Cedar St. Spruce St. Ln City Of Edmonds Building Department Work REMODEL Address 924 MAPLE Owner CHROSTOWSKA Approved Date 01 /23/2025 Building Official wwv'ta ----------------------- ---------------------- Permit Number BLD2025-0029 9. GLAZING U VALUE VERTICAL = .30U VALUE OR BETTER, OVERHEAD U VALUE =.50, CEILING R VALUE=R-49, WALL R VALUE=21, FLOOR INSUATION R-30, SLAB R VALUE=R-10 10. COMPLY WITH IBC 2021', IRC 2021', IMC 2021', IFC 2021', UPC 2021, WSEC 2021. 11. ADDRESS NUMBERS (6" HEIGHT ON APPR. CONTRASTING BACKGROUND) SHALL BE POSTED PLAINLY VISIBLE & LEGIBLE FROM STREET OR ROAD FRONTING PROPERTY. 12. PROVIDE FIRE ESTINGUISHERS PER IFC STANDARD 10-1. Ln Hemlock St. Q L L FA Val v Q L rn Walnut St. D rD in TABLE OF. CONTENTS COVER SHEET: Pi VICINITY MAP, PROJECT INFO., ENERGY WORKSHEETS ARCHITECTURAL: Al EX. BASEMENT FLOOR PLAN A2 REMO BASEMENT FLOOR PLAN 5YM50L5 INDICATE5 EXI5TING EXTERIOR WALL INDICATE5 EX. FOUNDATION WALL 0 INDICATE5 EXI5TING INTERIOR WALL o INDICATE5 NEW 2X4 @ 16" O.C. INDICATE5 WALL TO BE REMOVED INDICATE5 NEW 2X6 @ 16" O.C. STUD WALL W/ R-21 (EXT TYPE) O 120V 5MK PET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 515 CFM FAN COMPLY WITH M1507, 2015 IRC EX. BASEMENT - FLOOR PLAN 5CALE:1/4" = 1'-O" EX. LIVING: 779.32 5Q. FT. EX. EXTERIOR 5TORAGE:140.00 5Q. FT. EX. CARPORT: 561.00 5Q. FT. 5YM50L5 INPICATE5 EXI5TING EXTERIOR WALL IN[)ICATE5 EX. FOUNDATION WALL 0 INPICATE5 EXI5TING INTERIOR WALL o INPICATE5 NEW 2X4 @ 16" O.C. INPICATE5 WALL TO BE REMOVE[) INPICATE5 NEW 2X6 @ 16" O.C. 5TUP WALL W/ R-21 (EXT TYPE) O 120V 51VIK PET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 515 CFM FAN COMPLY WITH M1507, 2015 IRC PROVIDE EXHAUST FAN W/ 50CFM MIN VENTED TO OUTSIDE FLOOR PLAN 5CALE:1/4" = 1'-O" NO CHANGE TO 50. FT.