Loading...
APPROVED PLN BLD RESUB 1-BLD2024-1502+Architectural_Plan+12.18.2024_4.15.44_PM+4677736: THE FOLLOWING DOCUMENTATION SHALL BE AVAILABLE ON SITE FOR THE BUILDING INSPECTOR: : VCOE APPROVED ARCHITECTURAL PLAN SET : ❑ COE APPROVED STRUCTURAL PLAN SET n COE REVIEWED CALCULATION PACKET : ❑ENERGY CREDIT WORKSHEET ❑ SITE PLAN ❑ CIVIL PLAN ■ ❑ ■ ❑ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 Johnson Attic Interior Remodel Parcel No.: 00434600200300 18612 Soundview Place Edmonds, WA 98020 OWNER: Jeff and Kathrine Johnson JUISDICTION: City of Edmonds 18612 Soundview Place Edmonds, WA 98020 PROJECT ADDRESS: 18612 Soundview Place Edmonds, WA 98020 ARCHITECT: Designs NW Architects Dan Nelson PARCEL NO.: 00434600200300 26915 102nd Dr. NW Stanwood, WA 98292 CODE: 2021 IRC with Washington 360-629-3441 dan@designsnw.com mend e s CONTRACTOR: McMorrow Construction, LLC Matt McMorrow TAL: 15152 McLean Rd. 7MAKEU Mount Vernon, WA 98273 HOLE HOUSE VENTILATION) 360-610-7259 CTION R303.4 AND M1505 mcmorrowconstruction@gmail.com M1503.6 Lic# MCMORCL78ONW DESIGNS Johnson Attic Interior Remodel northwest ARCHITECTS PN: 00434600200300 OBTAIN A SEPARATE PLUMBING PERMIT FROM THE CITY OF EDMONDS. -------------------------- - - - - -, A separate Mechanical permit (BLD2024-0631) has been obtained for this project. -------------------------------- SHEETINDEX ALL WORK SUBJECT APPROVED OBTAIN ELECTRICAL c TO FIELD PLANS MUST BE PERMIT FROM INSPECTION FOR ON JOB SITE STATE LABOR & CODE COMPLIANCE INDUSTRIES City Of Edmonds Building Department ------------- Work ATTIC REMODEL Address ------------------------------------------ 18612 SOUND VIEW PL Owner JOHNSON Approved Date 1/14/2025 ----------------------------- Building Official VfACL[L Permit Number ------------------------------------ BLD2024-1502 RESUB Dec 19 2024 CITY OF EDMONDS DEVELOPMENTS ERVICES DEPARTMENT A0.1 Cover Sheet ti 1 thttu A1.0 (E) House Floor Plan - Entry Level CT A1.1 (E) House Floor Plan - Kitchen and Family Level A1.2 (E) House Floor Plan - Landing at DMAWME A. N Proposed Revisions A2.1 Attic As -Built and Proposed Floor STATE OF WA$�N�i'iCaN Plan A2.2 Roof Plan A2.3 Sections No. Description Date 1 Per City Comments 12-17-20 24 18612 Soundview Place Edmonds, WA 98020 Sheet Number: Project Number: Date: Designed: Drawn: AO. 1 12E 0- co 2024-51 CD 10-14-2024 N O JZ N JZ © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. LOCATION OF NEW EXTERIOR MECHANICAL EQUIP. DESIGNS Johnson Attic Interior Remodel northwest ARCHITECTS PN:00434600200300 RESUB Dec 19 2024 CITY OF EDMONDS DEVELOPMENTS ERVICES DEPARTMENT �sseo n DAME STATE OF No. Description Date 1 Per City Comments 12-17-20 24 Sheet Number: N 18612 Soundview Place Date: Edmonds, WA 98020 Designed: Drawn: A1.0 20 -61 N 10-14-2024 N Author Checker N © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. Landing at Proposed Revisions 1 /8" = 1'-0" DESIGNS Johnson Attic Interior Remodel northwest ARCHITECTS PN:00434600200300 RESUB Dec 19 2024 CITY OF EDMONDS DEVELOPMENTS ERVICES DEPARTMENT �sseo n DAtNE STATE OF No. Description Date 1 Per City Comments 12-17-20 24 Sheet Number: 18612 Soundview Place Date: Edmonds, WA 98020 Designed: Drawn: A1.2 -- , �20-24-81 10-14-2024 Author Checker © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. 8'-7" 13'-11" V V FLOOR PLAN INFO: 3 1 HABITABLE AREA TOTAL OVER 5'-0" EA2.3 A2.3 HABITABLE AREA: UNDER 7'-0" �>__ NON -HABITABLE SPACE A � �J_ UNDER 5'-0"M _J NON -HABITABLE SPACE 4'- 4 7/8" 8' - 5 1/2" _ _J r` UNDER 5'-0" TORAGE �� o M --- --2—--------------�---- B i A2.3 00-800 CFM � HABITABLE AREA HABITABLE AREA UNDER T-0" _ J UNDER T-0" KITCHEN -- - - - - - ---- -- --- 17 L------ g - PERMITTED 10 A - BASE WALL MINI SPLIT PERMITTED N MINI-S LIT — 50 CFM DN OPEN AREA 12'-0" 3'-01/2" 18 oe (E) STAIRS TO--------------- — \REMAIN HABITABLE AREA \\\Zl 1 SAC UNDER 7'-0HABITABLE AREA \ " UNDER T-0" SMOKE/CARBON MONOX. ALL EXISTING DETECTORE EXTERIOR WALLS, WINDOWS, AND INTERIOR C LUMNS LNON-HABDITAB5LE SPACE TO REMAIN NON -HABITABLE SPACE UNER '-0" 1 UNDER 5'-0" 1 Attic FF 1 /4" = 1'-0" DESIGNS northwest ARCHITECTS THIS IS NOT AN ADU Johnson Attic Interior Remodel PN: 00434600200300 460 SF 169 SF - LESS THAN 50% WALL LEGEND A 2X6 FRAMING @ 16" O.C. 5/8" GYP, BOTH SIDES B 0 2X4 FRAMING @ 16" O.C. PER PLAN NOTES: 1. ALL PROPOSED 2X WALLS ARE NON -BEARING 2. MECHANICAL AND ELECTRICAL INSTALLED WITH ISSUED PERMITS 3. EXISTING ATTIC EXTERIOR SHELL AND STRUCTURAL SYSTEM TO REMAIN INCLUDING EXISTING STAIRS AND WINDOWS. 4. EXISTING STAIR LIGHTING TO REMAIN 5. SMOKE/CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED AND HARD WIRED WITH THE EXISTING SYSTEM WITH A 90MIN BACKUP BATTERY. PPROVED BY PLANNING Jan 23 2025 Not Approved as an Accessory Dwelling Unit RESUB Dec 19 2024 CITV OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �sseo n DAME STATE OF No. Description Date 1 Per City Comments 12-17-20 24 Sheet Number: Project Number: 18612 Soundview Place Date: Edmonds, WA 98020 Designed: Drawn: A2.1 2024-51 10-14-2024 JZ JZ © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. n Roof Plan ' 1 /4'1 = 1'-011 DESIGNS northwest ARCHITECTS Johnson Attic Interior Remodel �III�C�:�III�IIII�C�III� RESUB Dec 19 2024 CITY OF EDMONDS DEVELOPMENTS ERVICES DEPARTMENT No. Description Date 1 Per City Comments 12-17-20 24 Sheet Number: A2.2 18612 Soundview Place Date: Edmonds, WA 98020 Designed: Drawn: Q24=51 N 10-14-2024 N C JZ JZ N © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service. N/S AT DORMERS 1 /4" = 1'-0" DESIGNS northwest ARCHITECTS 1 E) ATTIC EXTERIOR_ ENVELOPE_ 1 /41' = 1'-091 Johnson Attic Interior Remodel WWI IIMC�I$][$We] IW X X Ed HABITABLE AREA NON -HABIT MAREAI POSITIVE CONNECTION AT TOP PLATE AT ANGLED CEILING BLOCKING AS NEEDED NON -BEARING 2X WALL WITH 1/2" GWB BOTH SIDES POSITIVE CONNECTION AT 2X SILL PLATE TO FLOOR (E) BAFFLED ROOF RAFTERS WITH R-19 INSULATION, AND T&G CEILING FINISH (E) EXTERIOR WALL FRAMING WITH R-15 INSULATION, AND T&G FINISH (E) FLOOR JOISTS WITH R-30 INSULATION, PLYWOOD ATTIC FLOOR AND 5/8" TYPE "X" GYPSUM ON GARAGE CEILING WITH FIRE TAPED JOINTS RESUB Dec 19 2024 CITY OF EDMONDS DEVELOPMENTS ERVICES DEPARTMENT �sseo n DAME STATE OF No. Description Date 1 Per City Comments 12-17-20 24 2�NON-BEARING WALL _ I Sheet Number: 1/211 = 1'-0" Project Number: 18612 Soundview Place Date: Edmonds, WA 98020 FDr signed: wn: A2.3 12E a 2024-51 LO N 10-14-2024 N O JZ JZ N © Copyright 2024 - Property of DNWA, Inc. & is an Instrument of Service.