Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD RESUB1 BLD2024-0235+MANUFACTURER SPECS+6.30.2024_10.51.35_AM+4350973
j IF] 420 wP t T 'REE20.1W 25 YAR �Tz PROTRUST NARRANTY 21.7%EFFICIENCY ELIGIBLE t4#7 LEAD-FREE ROHS COMPLIANT ISTED RE C LEOMPAIT PANEL SIZE EXPERIENCE PERFORMANCE GENERALDATA ' Celltype: 132 half -cut REC heterojunction cells with lead-free, gapless technology, 6 strings of22 cells in series Glass: 0.12 in solarglass with anti -reflective surface treatment in accordance with EN 12150 Backsheet: Highly resistant polymer (black) Frame: Anodized aluminum (black) Junction box: 3-part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors: Staubli MC4 PV-KBT4/KST4(12 AWG) in accordance with IEC 62852, IP68 onlywhen connected Cable: 12 AWG solar cable, 49.2+49.2 in in accordancewith EN 50618 Dimensions: 73.4x40.9x 1.2 in (20.88 sq-ft) Weight: 47.6lbs (21.6 kg) Origin: Made in Singapore ELECTRICAL DATA Power Output - PM (Wp) 400 Watt Class Sorting -(W) 0/+10 Nominal Power Voltage-VMPP(V) 41.1 Nominal Power Current - IMPP(A) 9.74 H Open Circuit Voltage - Voc(V) 48.5 Short Circuit Current - Isc(A) 10.60 Power Density (W/ft2) 19.2 Panel Efficiency (%) 20.6 +1 a f 1.8 0.9 27.3±0.1 1.2 Measurements in inches Imm) Product Code': RECxxxAA PURE 2 1 9- 410 420 430 0/+10 0/+10 0/+10 41.6 42.2 42.8 9.86 9.96 10.05 48.8 49.1 49.3 10.67 10.74 10.81 19.6 20.1 20.6 21.1 21.7 22.2 Power Output - PMAx(WP) 304 312 320 327 I - Nominal Power Voltage -VMPP(V) 38.7 39.2 39.8 40.3 C) Nominal Power Current-IMPP(A) 7.86 7.96 8.05 8.12 Z Open Circuit Voltage - Voc(V) 45.7 45.8 46.0 46.2 Short Circuit Current - Isc(A) 8.50 8.62 8.68 8.73 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m2), temperature 77°F (25°C), based on a production spread with a tolerance of PM V°c & Isc±3%within one watt class. Nominal module operatingtemperature (NMOT: air mass AM 1.5, irradiance 800 W/m2, temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s).* Where xxx indicates the nominal power class (P.) at STC above. MAXIMUM RATINGS Operational temperature: -40...+85°C System voltage: 1000V Test load (front): +7000 Pa (1461bs/ft2)' Test load (rear): -4000Pa(83.51bs/ft2)" Series fuse rating: 25A Reverse current: 25A See installation manual for mounting instructions. Design load =Test load/1.5 (safetyfactor) Availablefrom: IWARRANTY ' Standard REC ProTrust Installed byan REC No Yes Yes Certified Solar Professional System Size All Q5 kW 25-500 kW Product Warranty (yrs) 20 25 25 Power Warranty (yrs) 25 25 25 Labor Warranty (yrs) 0 25 10 Power in Year] 98% 98% 98% Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% See warranty documents for details. Conditions apply Founded in1996, REC Group is an international pioneeringsolarenergy company dedicated to empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia -Pacific. CERTIFICATIONS I EC 61215:2016, IEC 61730:2016, U L 61730 IEC62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL61730 Fire Type 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC62321 Lead-freeacc. to ROHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 o"E Eib , C E ❑� �T Intertek Lead -Free TEMPERATURE RATINGS' to Nominal Module OperatingTemperature: 44°C(±2°C) c Temperature coefficient of PMAX: 0.24 %/°C o Temperature coefficient of Voc: -0.24 %/°C v m Temperature coefficient of Isc: 0.04 %/°C The temperature coefficients stated are linear values DELIVERY INFORMATION w Panels per pallet: 33 0 Panelsper40ftGP/high cube container: 792 (24 pallets) - Panels per 53fttruck: 858 (26 pallets) LOW LIGHT BEHAVIOUR N w Typical low irradiance performanceof module atSTC: v o � u � ; ---------I I------------1---------: a w I I 1 I lE a W o � a Po Po Irradiance (W/m') REC Solar PTE. LTD. 20 Tuas South Ave.14 Singapore 637312 post@recgroup.com www.recgroup.com REC t:) ENPHASE DATA SHEET IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8M and IQ8A support split -phase, 240V installations only. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer's instructions. Easy to install Lightweight and compact with plug-n- play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high-powered PV modules Microgrid-forming Complies with the latest advanced grid support** Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 311 Ed.) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (I07 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-12A-DS-0069-03-EN-US-2022-12-27 IQBM and IQBA Microinverters Commonly used module pairings' W Module compatibility MPPT voltage range V Operating range V Min. / Max. start voltage V Max. input DC voltage V Max. continuous input DC current A Max. input DC short-circuit current A Max. module Is A Overvoltage class DC port DC port backfeed current mA PV array configuration Peak output power VA Max. continuous output power VA Nominal (L-L) voltage / range' V Max. continuous output current A Nominal frequency Hz Extended frequency range Hz AC short circuit fault current over 3 cycles Arms Max. units per 20 A (L-L) branch circuit' Total harmonic distortion Overvoltage class AC port AC port backfeed current mA Power factor setting Grid -tied power factor (adjustable) Peak efficiency CEC weighted efficiency Night-time power consumption mW Ambient temperature range Relative humidity range DC Connector type Dimensions (H x W x D) Weight Cooling Approved for wet locations Pollution degree Enclosure Environ. category / UV exposure rating 260 - 460 295 - 500 54-cell / 108 half -cell, 60-cell / 120 half -cell, 66-cell / 132 half -cell and 72-cell / 144 half -cell 30 - 45 32 - 45 16-58 22 / 58 60 12 25 20 11 O 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit 330 325 1.35 97.8 97.5 240 / 211 - 264 60 47 - 68 11 <5 III 30 1.0 0.85 leading - 0.85 lagging 60 366 349 1.45 97.7 97 -40°C to +60°C (-40°F to +140°F) 4% to 100% (condensing) MC4 212 mm MY) x 175 mm (6.9") x 30.2 mm 0.2") 1.08 kg (2.38 Ibs) Natural convection - no fans Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://Iink.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-I2A-DS-0069-03-EN-US-2022-12-27 S 5�� The Right Way! S-5-S Clamp The S-S-S clamp was created specifically for popular snap -together profiles — including residential profiles by Taylor Metals and Easy Lock Standing Seam. For horizontal seams under .540 inches (like the Firestone UC4) the S-S-S or S-S-S Mini can be used to avoid the necessity of crimping the seam. Its simple design and size make it perfect for use with S-5!° snow retention products and other heavy-duty applications. Installation is as simple as setting the patented round -point setscrews into the clamp, placing the clamp on the seam, and tightening them to the specified tension. Then, affix ancillary items using the bolt provided with the product. Go to www.S-5.com/tools for information and tools available for properly attaching and tensioning S-5! clamps. -5-S Mini Clamp The S-S-S Mini is a bit shorter than the S-S-S and has one setscrew rather than two. The mini is the choice for attaching all kinds of rooftop accessories: signs, walkways, satellite dishes, antennas, rooftop lighting, lightning protection systems, solar arrays, exhaust stack bracing, conduit, condensate lines, mechanical equipment —just about anything!* *S-51 mini clamps are not compatible with, and should not be used with 5-51 SnoRailT"/SnoFenceT1 or ColorGard® snow retention systems. M3 The S-5-S clamp was created specifically for popular snap -together profiles. U) LO U) E O U Ln Ch N M M Lh N oO MI MW MW W The S-5-S and 5-5-5 Mini clamps are each furnished with the hardware shown to the right. Each box also includes a bit tip for tightening setscrews using an electric screw gun. A structural aluminum attachment clamp, the S-5-S is compatible with most common metal roofing materials excluding copper. All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details, metallurgical compatibilities and specifications. The S-5-S clamp has been tested for load -to -failure results on most major brands and profiles of standing seam roofing. The independent lab test data found at www.S-5.com can be used for load -critical designs and applications. S-5!° holding strength is unmatched in the industry. Profiles that are shaped as illustrated below will work with the S-5-S and S-5-S Mini. In order for the S-5-S or S-5-S Mini to fit these types of seams, the finished seam must: • Be at least 1.00" high. • Have a height distance less than or equal to 0.25" between the male portion of the panel and female portion of the panel. Example Profiles I S-5-S Clamp 2.00" (51.00 mm) 0.50" 1.50" �0 12. M8-1.25 X 16.00 mm �— Hex Flange Bolt 0.50" 2.70 mm) (2x) M8-1.25 Threaded Hole T 0.911, (23.00 m ) O 1 (14.00 m 1.50" (38.00 mm) _�� Two 3/8-24 X 0.80" Round -Point Setscrews S-5-S Mini Clamp 1.18" (30.00 mm) 1.50" (38.00 mm) I50" —" (38.00 mm)--_� — M8-1.25 X 16.00 mm Hex Flange Bolt i One 3/8-24 X 0.80" Round -Point Setscrews Please note: All measurements are rounded to the second decimal place. 5-5!® Warning! Please use this product responsibly! Distributed by Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews should be tensioned and re -tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges ofsteel. Consult the S-5! website at www.S-5.com for published data regarding holding strength. Copyright 2015 Metal Roof Innovations, Ltd. S-5! products are patent protected. S-51 aggressively protects its patents, trademarks and copyrights. Version 052115.