REVIEWED BLD2022-1329+Structural_Calculations+8.10.2022_9.45.31_AM+3042472BUILT engineering
STRUCTURAL CALCULATIONS
Project:
310 Daley Townhomes
310 Daley St
Edmonds, WA 98020
Architect:
Citizen Design
10 Dravus St
Seattle, WA 98109
Engineer:
Built Engineering
539 Broadway
Ste 305
Tacoma, WA 98402
BLD2022-1325
- 308 DALEY
- LOT B
BLD2022-1326
- 310 DALEY -
LOT C
BLD2022-1327
- 312 DALEY -
LOT D
BLD2022-1329
- 306 DALEY
- LOT A
RECEIVED
Nov 16 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
,.,.....,.
REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT.
BUILT engineering
CRITERIA
Gravity
roof
dead
asphalt shingles
2.5 live snow 25.0 psf
1/2" plywood
1.5
trusses @ 24" oc
4.2
R42 insulation
1.5
5/8" gyp. wallboard
2.8
miscellaneous
2.5 17%
15.0 psf
total
dead + snow
40.0 psf
floor
dead
vinyl flooring
1.0 live residential 40.0 psf
6" MPP panel
18.5
miscellaneous
1.5 7%
21.0 psf
total
dead + live
61.0 psf
walls
cement fiber siding
2.5
1/2" plywood
1.5
2x6 @ 16"oc
1.7
R21 insulation
0.8
1/2" gyp. wallboard
2.2
miscellaneous
1.3 13%
10.0 psf
Lateral
wind
wind importance factor
1.0
basic wind speed
110 mph
wind exposure
D
topographical factor (Kzt)
1.00
seismic
seismic importance factor
1.0
latitude
47.813 °
longitude
-122.377 °
mapped spectral response
1.288 g (from USGS)
accel. at short periods (Ss)
seismic design category
D
response modification factor (R)
6.5 (plywood shearwalls)
539 Broadway, #305
Tacoma, WA 98402 3/11/2022
tel - 253-985-5008 Page of
ROOF FRAMING
R4
0
u
AMA
R2
THIRD FRAMING
SECOND FRAMING
MPP ASD Reference Design Values
Major Strength Direction I Minor Strength Direction
F16-2
2
37
6.2
1,110
16
0.82
2,190
210
2.8
0.17
695
F16-3
3
37
9.3
1,870
51
1.23
2,190
355
9
0.26
695
F16-4
4
37
12.3
3,325
122
1.64
2,925
630
21
0.34
930
F16-5
5
37
15.4
5,200
238
2.05
3,650
985
42
0.43
1,160
F16-6
6
37
18.5
7,500
410
2.46
4,375
1,420
72
0.69
1,390
F16 F16-7
7
37
21.6
10,200
652
2.66
5,100
1,930
114
0.81
1,630
F16-8
8
37
24.7
13,325
973
3.04
5,825
2,525
170
0.91
1,860
F16-9
9
37
27.
16,850
1,385
3.42
6,575
3,200
242
1.04
2,090
F16-10
10
37
30.8
20,825
1,900
3.8
7,300
3,950
333
1.15
2,320
F16-11
11
37
33.9
25,175
2,529
4.18
8,025
4,775
443
2,550
0
J==JJ6M
F16-12
12
37
37.0
29,975
3,283
4.56
8,750
5,675
575
1.38
2,775
SIMPLE SPAN DESIGN - 6"MPP PANEL
L (ft) 19.5
W (plf) 61
W (live, plf) 40
El 4.10E+08 MAX
V 0.59475
M 2.89941
Vr
4.3 k
Mr
7.5 k-ft
defl (total)
0.48
L/
483 690.6386
defl (live)
0.32
L/
737
SIMPLE SPAN BEAM DESIGN - 6" MPP PANEL
12" strip minor streneth direction at stair openine
Beam Width
12
Beam Depth
6
L (ft)
5.5
W (plf)
549
W (live, plf)
360
El
7.20E+07
V 1.50975 Vr 4.3 k
M 2.07590625 Mr 7.5 k-ft
defl (total) 0.16
L/ 420 600.5826
defl (live) 0.10
L/ 641
USE 6" F16 MPP PANEL
USE 6" F16 MPP PANEL
aFORTE'CM
Roof, R1
1 piece(s) 4 x 10 DF No.1
PASSED
FBI
V'Jerall Length: 7 6
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3181 @ 1 1/2"
6563 (3.00")
Passed (48%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
2315 @ 1' 1/4"
4468
Passed (52%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
5573 @ 3' 9"
5740
Passed (97%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.083 @ 3' 9"
0.242
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.134 @ 3' 9"
0.363
Passed (L/648)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
1212
1969
3181
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
1212
1969
3181
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
7' 6" o/c
Bottom Edge (Lu)
7' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 76"
N/A
8.2
--
1 - Uniform (PSF)
0 to 7' 6"
21'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 2 / 12
aFORTE'CM
Roof, R2
1 piece(s) 4 x 10 DF No.1
PASSED
V'Jerall Length:
(. 8 9 i,
1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2258 @ 1 1/2"
6563 (3.00")
Passed (34%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
1760 @ 1' 1/4"
4468
Passed (39%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
4943 @ 4' 7 1/2"
5740
Passed (86%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.113 @ 4' 7 1/2"
0.300
Passed (L/957)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.184 @ 4' 7 1/2"
0.450
Passed (L/588)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
870
1388
2258
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
870
1388
2258
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
9' 3" o/c
Bottom Edge (Lu)
9' 3" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 9' 3"
N/A
8.2
--
1 - Uniform (PSF)
0 to 9' 3"
12'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes 911111111111111111
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 3 / 12
aFORTE'CM
Roof, R3
2 piece(s) 2 x 8 HF No.2
PASSED
FBI
V'Jerall Length: 3 6
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
850 @ 1 1/2"
3645 (3.00")
Passed (23%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
435 @ 10 1/4"
2501
Passed (17%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
641 @ 1' 9"
2569
Passed (25%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.006 @ 1' 9"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
1 0.010 @ 1' 9"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
325
525
850
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
325
525
850
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
3' 6" o/c
Bottom Edge (Lu)
T 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 6"
N/A
5.5
--
1 - Uniform (PSF)
0 to 3' 6"
12'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 4 / 12
aFORTE'CM
Roof, R4
2 piece(s) 2 x 8 HF No.2
PASSED
FBI
V'Jerall Length: 6
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
621 @ 1 1/2"
3645 (3.00")
Passed (17%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
479 @ 10 1/4"
2501
Passed (19%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1087 @ 3' 9"
2569
Passed (42%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.050 @ 3' 9"
0.242
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.083 @ 3' 9"
0.313
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/5/16").
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
246
375
621
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
246
375
621
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
7' 6" o/c
Bottom Edge (Lu)
7' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 76"
N/A
5.5
--
1 - Uniform (PSF)
0 to 7' 6"
4'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 5 / 12
.I F O R T E M) MEMBER REPORT PASSED
Third, Tl
1 piece(s) 4 x 10 OF No.1
Overall Length: 7 6'
I
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3080 @ 1 1/2"
6563 (3.00")
Passed (47%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
2241 @ 1' 1/4"
4468
Passed (50%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-Ibs)
5396 @ 3' 9"
5740
Passed (94%)
1.15
1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)
0.074 @ 3' 9"
0.242
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.130 @ 3' 9"
0.363
Passed (L/669)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Available Required
Loads to Supports (Ibs)
Accessories
Floor Live
Snow
Total
1 - Trimmer - HF
3.00'.
3.00"
1.50"
1336
1200
1125
3661
None
2 - Trimmer - HF
3.00"
3.00"
1.50"
1336
1200
1125
3661
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
7' 6" o/c
Bottom Edge (Lu)
7' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 7' 6"
N/A
8.2
1 - Uniform (PSF)
0 to 7' 6"
8'
21.0
40.0
-
floor
2 - Uniform (PSF)
0 to 7' 6"
12'
15.0
-
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 6 / 12
aFORTE'CM
Third, T2
2 piece(s) 2 x 8 HF No.2
PASSED
V'reraiI Length:4 6
- 1 0
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
580 @ 4' 4 1/2"
3645 (3.00")
Passed (16%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
461 @ 10 1/4"
2501
Passed (18%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
862 @ 2'
2569
Passed (34%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.012 @ 2' 3 1/4"
0.142
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.020 @ 2' 3 1/4"
0.213
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
190
276
466
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
231
349
580
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
4' 6" o/c
Bottom Edge (Lu)
4' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Snow
Vertical Loads
Location
Tributary Width
(0.90)
(1.15)
Comments
0 - Self Weight (PLF)
0 to 4' 6"
N/A
5.5
1 - Point (lb)
2'
N/A
246
375
Linked from: R4,
Support 1
2 - Uniform (PSF)
2' to 4' 6"
4'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 7 / 12
aFORTE'CM
Third, T3
2 piece(s) 2 x 8 HF No.2
PASSED
FBI
V'rerall Length: 6 6
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
538 @ 1 1/2"
3645 (3.00")
Passed (15%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
397 @ 10 1/4"
2501
Passed (16%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
808 @ T 3"
2569
Passed (31%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.028 @ 3' 3"
0.208
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.046 @ 3' 3"
0.313
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
213
325
538
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
213
325
538
None
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
6' 6" o/c
Bottom Edge (Lu)
6' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 6' 6"
N/A
5.5
--
1 - Uniform (PSF)
0 to 6' 6"
4'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes 911111111111111111
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 8 / 12
aFORTE'CM
Third, T4
2 piece(s) 2 x 8 HF No.2
PASSED
FBI
V'rerall Length: 3 6
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
FBI
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
1480 @ 1 1/2"
3645 (3.00")
Passed (41%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
757 @ 10 1/4"
2501
Passed (30%)
1.15
1.0 D + 1.0 S (All Spans)
Moment (Ft-Ibs)
1116 @ 1' 9"
2569
Passed (43%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.011 @ 1' 9"
0.108
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.017 @ 1' 9"
0.162
Passed (L/999+)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.50"
561
919
1480
None
2 - Trimmer - HF 3.00"
3.00" 1
1.50"
561
919
1480
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
3' 6" o/c
Bottom Edge (Lu)
T 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 6"
N/A
5.5
--
1 - Uniform (PSF)
0 to 3' 6"
21'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 9 / 12
aFORTE'CM
Second, S1
1 piece(s) 5 1/8" x 10 1/2" 24F-V4 DF Glulam
PASSED
(,: 1' I
f
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
121 @ 1 1/2"
9994 (3.00")
Passed (1%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
93 @ 1' 1 1/2"
8556
Passed (1%)
0.90
1.0 D (All Spans)
Pos Moment (Ft-Ibs)
432 @ 8' 3"
16951
Passed (3%)
0.90
1.0 D (All Spans)
Live Load Defl. (in)
0.000 @ 0
0.542
Passed (2L/999+)
1.0 D (All Spans)
Total Load Defl. (in)
0.023 @ 8' 3"
0.813
Passed (L/999+)
1.0 D (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Trimmer - HF
3.00"
3.00"
1.50"
113
8
121
None
2 - Trimmer - HF
3.00"
3.00"
1.50"
108
-
108
None
Lateral Bracing sm
Bracing Intervals
Comments
Top Edge (Lu)
16' 6" o/c
Bottom Edge (Lu)
166" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF) 0 to 16' 6"
N/A
13.1
1 - Uniform (PSF) 0
4'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 10 / 12
.I F O R T E M) MEMBER REPORT PASSED
Second, S2
1 piece(s) 5 1/8" x 10 1/2" 24F-V4 DF Glulam
overall Length: 126'
1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
5988 @ 1 1/2"
9994 (3.00")
Passed (60%)
1.0 D + 1.0 S (All Spans)
Shear (Ibs)
4910 @ 1' 1 1/2"
10933
Passed (45%)
1.15
1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-Ibs)
17971 @ 6' 3"
21660
Passed (83%)
1.15
1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)
0.342 @ 6' 3"
0.408
Passed (L/430)
1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)
0.545 @ 6' 3"
0.613
Passed (L/269)
1.0 D + 1.0 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 12' 3".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Supports
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Snow
Total
1 - Trimmer - HF
3.00"
3.00"
1.80"
2238
3750
5988
None
2 - Trimmer - HF
3.00"
3.00"
1.80"
2238
3750
5988
None
Lateral Bracing sm
Bracing Intervals
Comments
Top Edge (Lu)
12' 6" o/c
Bottom Edge (Lu)
12' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Location
Tributary Width
Dead
(0.90)
Snow
(1.15)
Comments
0 - Self Weight (PLF) 0 to 12' 6"
N/A
13.1
1 - Uniform (PSF) 0 to 12' 6"
21'
15.0
25.0
roof
2 - Uniform (PSF) 0 to 12' 6"
3'
10.0
25.0
entry canopy
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 11 / 12
aFORTE'CM
Second, S3
2 piece(s) 2 x 8 HF No.2
PASSED
1
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2414 @ 1 1/2"
3645 (3.00")
Passed (66%)
1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (Ibs)
1204 @ 10 1/4"
2175
Passed (55%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
1775 @ 1' 9"
2234
Passed (79%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.016 @ 1' 9"
0.108
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)
0.028 @ 1' 9"
0.162
Passed (L/999+)
1.0 D + 0.75 L + 0.75 S (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Applicable calculations are based on NDS.
Bearing Length
Supports Available Required
Loads to Supports (Ibs)
Accessories
Dead
Floor Live
Snow
Total
1 - Trimmer - HF 3.00"
3.00"
F 1.99"
1023
1330
525
2878
None
2 - Trimmer - HF 3.00"
3.00" 1
1.99"
1023
1330
525
2878
None
Lateral Bracing
Bracing Intervals
comments
Top Edge (Lu)
3' 6" o/c
Bottom Edge (Lu)
3' 6" o/c
-Maximum allowable bracing intervals based on applied load.
Vertical Loads
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Snow
(1.15)
Comments
0 - Self Weight (PLF)
0 to 3' 6"
N/A
5.5
1 - Uniform (PSF)
0 to 3' 6"
9' 6"
21.0
40.0
second floor
2 - Uniform (PSF)
0 to 3' 6"
9' 6"
21.0
40.0
third floor
3 - Uniform (PSF)
0 to 3' 6"
12'
15.0
25.0
roof
System: Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
3/11/2022 9:06:19 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 12 / 12
aFORTE'CM
Second, S4
1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam
PASSED
Overall Length: 13 9'
o � o
18' 2'
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @ Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2569 @ 18' 7"
8181 (3.50")
Passed (31%)
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2557 @ 17' 8 1/2"
8745
Passed (29%)
1.00
1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-Ibs)
9122 @ 15'
14850
Passed (61%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.423 @ 10' 6 11/16"
0.614
Passed (L/523)
1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)
0.696 @ 10' 5 9/16"
0.921
Passed (L/318)
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Allowed moment does not reflect the adjustment for the beam stability factor.
• Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 18' 5".
• The effects of positive or negative camber have not been accounted for when calculating deflection.
• The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
• Applicable calculations are based on NDS.
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 - Stu�wall-
3.50"
3.50"
1.50"
317
389
706
Blocking
2 - Stud wall - SPF
3.50"
3.50"
1.50"
958
1611
2569
Blocking
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
18' 9" o/c
Bottom Edge (Lu)
18' 9" o/c
-Maximum allowable bracing intervals based on applied load.
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 - Self Weight (PLF)
0 to 18' 9"
N/A
12.0
--
1 - Point (lb)
15' (Top)
N/A
525
1000
25 sf trib second
floor and stair
2 - Point (lb)
15' (Front)
N/A
525
1000
25 sf trib third floor
and stair
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC
ForteWEB Software Operator
Job Notes
Brice Parrish
Built Engineering
(253) 985-5008
briceparrish@gmaii.com
5/23/2022 7:20:18 PM UTC
ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: 310 Daley
Page 1 / 1
310 Daley Townhomes
310 Daley St, Edmonds, WA 98020, USA
Latitude, Longitude: 47.8135949,-122.3773285
Sunset Beach
1
Brackett, s
Landirig North
Rory's of Edmonds
Google „
Date
Design Code Reference Document
Risk Category
Site Class
Edmonds Center
For the Arts
Z
faley St
Fd�
°na
SSA Sprague St
3/10/2022, 2:39:18 PM
ASCE7-16
11
D - Default (See Section 11.4.3)
OSH PD
Type
Value
Description
SS
1.288
MCER ground motion. (for 0.2 second period)
S,
0.453
MCER ground motion. (for 1.0s period)
SMS
1.545
Site -modified spectral acceleration value
SM9
null -See Section 11.4.8
Site -modified spectral acceleration value
SDS
1.03
Numeric seismic design value at 0.2 second SA
SDI
null -See Section 11.4.8
Numeric seismic design value at 1.0 second SA
Type
Value
Description
SDC
null -See Section 11.4.8
Seismic design category
Fa
1.2
Site amplification factor at 0.2 second
Fv
null -See Section 11.4.8
Site amplification factor at 1.0 second
PGA
0.548
MCEG peak ground acceleration
FPGA
1.2
Site amplification factor at PGA
PGAM
0.657
Site modified peak ground acceleration
T,
6
Long -period transition period in seconds
SsRT
1.288
Probabilistic risk -targeted ground motion. (0.2 second)
SsUH
1.415
Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration
SsD
2.174
Factored deterministic acceleration value. (0.2 second)
S1 RT
0.453
Probabilistic risk -targeted ground motion. (1.0 second)
S1 UH
0.506
Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration.
S1 D
0.883
Factored deterministic acceleration value. (1.0 second)
PGAd
0.767
Factored deterministic acceleration value. (Peak Ground Acceleration)
CRS
0.91
Mapped value of the risk coefficient at short periods
Daley St
..
Map data 02022
WIND CRITERIA ASCE7-16Ch.27DirectionalProcedure
V = 110 mph Kd = 0.85
Exposure = C G = 0.85
h = 30 ft KZt = 1.00
Roof Slope = 4 : 12 = 18 °
PRESSURE COEFFICIENTS (Cp)
Windward Wall = 0.8 Windward Roof = 0.2
Leeward Wall = -0.5 Leeward Roof = -0.5
PRESSURE (PSF) q = 0.00256KZKZtKdV2
Ht
Kz
qz
0.6xgzt
qh
PWW
PLW
PWALL
PROOF
0-15
0.85
22.4
13.4
9.1
6.6
15.7
15-20
0.90
23.7
14.2
9.7
6.6
16.2
20-25
0.94
24.7
14.8
10.1
6.6
16.7
25-30
0.98
25.8
15.5
15.5
10.5
6.6
17.1
9.2
30-35
1.02
26.9
16.1
11.0
6.6
17.5
35-40
1.04
27.4
16.4
11.2
6.6
17.8
40-45
1.07
28.2
16.9
11.5
6.6
18.1
45-50
1.09
1 28.7
1 17.2
1 11.7
1 6.6
1 18.3
Per IBC 2018 1605.3.1 Basic Load Combinations
BUILT engineering
SEISMIC DESIGN
ASCE 7-16
Equivalent Lateral Force Procedure
Occupancy Category
Seismic Design Category
Importance Factor
Site Class
Ss
S1
Fa
Fv
Ct
x
hn
SMs
= Fa*Ss
SM1
= Fv*S1
SDS
= (2/3)*SMs
SD1 =
(2/3)*SM1
Period Ta = Ct*hn"x
To
Ts
Sa
R
Do
Cd
Section 9.5.5 ok?
II
Table 1-1
D
Table 11.6-1
1.00
Table 11.5-1
D
Table 20.3-1
128.80 %g
(from USGS Seismic Hazard Curves, 2008 data)
45.30 %g
(from USGS Seismic Hazard Curves, 2008 data)
1.20
Table 11.4-1
1.77
Table 11.4-2
0.02
Table 12.8-2
0.75
Table 12.8-2
27.00 feet
(height to highest level)
1.5456
Eq.11.4-1
0.8018
Eq.11.4-2
1.0304 g
Eq. 11.4-3
0.5345 g
Eq. 11.4-4
0.2369 s
Eq. 12.8-7
0.1038 s
per section 11.4.5
0.5188 s
per section 11.4.5
1.0304 g
per section 11.4.5
6.5
Table 12.2-1
3
Table 12.2-1
4
Table 12.2-1
Yes
Table 12.6-1
Equivalent Lateral Force Procedure (section 12.8)
Cs
W, weight
QE
0.1585 Eq.12.8-2
243,527 lb per table below
38,605lb Eq.12.8-1
Vertical Force Distribution (section 12.8.3)
k = 1.00
Floor
Floor
Floor
Wall
Wall
Total
Level
Hx
Area
Wt.
Wt.
psf
Wt.
Wt.
WxHx
(ft)
(ft2)
(psf)
(k)
(k)
(k)
(k-ft)
roof
27.00
2577
15
38.7
7.5
19.3
58.0
1565.5
third
16.50
2577
21
54.1
15
38.7
92.8
1530.7
second
8.00
2577
21
54.1
15
38.7
92.8
742.2
539 Broadway
Ste 305
Tacoma, WA 98406
tel. 253-985-5008
(LRFD) (ASD)
CVx
QE
0.7QE
(%)
(k)
(k)
40.8
15.75
11.02
39.9
15.40
10.78
19.3
7.46
5.23
243.5 3838.4 100.0 38.60 27.02
3/10/2022
Page of
ROOF LATERAL - SEISMIC IN ()
RHO = 1.0
PLATE = 8'
WIND=9.5*4'+4 * 16.7=105
' (7,(nv NN
O� C O 02 �
O (J7
' C) ;., (n co N N
(niCOG.)O
CO C11
O
N
F
r
Rxn 1.0(1.5)
Lwall 10.7
VPlf 93(140)
SW SW1
OT -(1.1)
HD CS16
H:W -
1.8(2.7)
38'
47(71)
SW1
THIRD LATERAL - SEISMIC IN ()
RHO = 1.0
PLATE = 8'
WIND=16.7X8.5'=142
N3pcn AA
cn - N N
6) cn O
O + V co
U) N A
CD
N q^
� O
O Op
Rxn
2.3(3.0)
4.2(5.4)
Lwall
31'
38
Vplf
74(97)
110(142)
SW
SW1
SW1
OT
()
.8(1.1)
HD
(DL>1.1)
H:W
r
II
�J
5
U)
W
U)
J CO
Co
Q �
�' II
W LO
Q 06
JC)00r
p II LO
z II W II
O Fp
IUOQz
U)R5�
1 4.7(10.8) 4.7(1"
133(137)
T t 1
Y
� o
(6 ZIn
CO M CO(
N
C,
Vh M�Co�
-i � >00�=
Rxn
4.7(10.8)
5.0(5.2)
4.7(10.8)
Lwall
8.5'
39'
26'
Vplf
552(1280)
128(133)
180(415)
SW
SW6
SW1
SW4
OT
3.0(7.0)
1.0(1.1)
1.4+1.4=2.8(3.3+1.9=5.2)
HD
HDU8
(dl=1.2k)
HDU4/HDU8 where accumulated
H:W
.75==>446 SW4 OK
Project Information 310 Daley Second Floor West shearwalls at end units
Code: Date:
Designer:
Client:
Project:
Wall Line:
Ll(ft)
V (lb)
Lol(ft) L2(ft)
P
x
c
L. N(ft)
Shear Wall Calculation Variables
VL
34001bf
Opening 1
Adj. Factor Method =1
21bs/I
Ll
3.75 ft
h.1
1.00 ftj
Wall Pier Aspect Ratio
Adj. Fai
L21
4.25 ft
ho
4.00 ft
Pl=ha L1= 1.07
N/A
hwau
8.00 ft
hb
3.00 ft
P2=hJL2= 0.94
N/A
Lwau
14.00 ft
Lol
6.00 ft
1. Hold-down forces: H = Vhwaii/Lwaii 1943 lbf
2. Unit shear above + below opening
First opening: val = vb1 = H/(ha+hb) = 486 pIf
3. Total boundary force above + below openings
First opening: 01=valx(Lol)= 2914 lbf
4. Corner forces
F1=01(Ll)/(L1+L2)= 1366 lbf
F2 = 01(L2)/(Ll+L2) = 1548 lbf
S. Tributary length of openings
T1 = (L1*Lol)/(Ll+L2) = 2.81 ft
T2 = (L2*Lol)/(Ll+L2) = 3.19 ft
6. Unit shear beside opening
v1= (V/L)(Ll+T1)/L1 =
425 pIf
v2 = (V/L)(T2+L2)/L2 =
425 pIf
Check vl*Ll+v2*L2=V?
3400 lbf OK
7. Resistance to corner forces
R1=v1*L1=
15941bf
R2=v2*L2=
18061bf
8. Difference corner force + resistance
RI-F1= 2281bf
R2-F2= 2581bf
9. Unit shear in corner zones
vc1 = (RI-F1)/L1 = 61 pIf
vc2 = (R2-F2)/L2 = 61 pIf
Check Summary of Shear Values for One Opening
Line 1: vc1(ha+hb)+v1(ho)=H? 243 1700 1943 lbf
Line 2: va1(ha+hb)-vc1(ha+hb)-v1(ho)=0? 1943 243 1700 0
Line 3: va1(ha+hb)-vc2(ha+hb)-v1(hj=0? 1943 243 1700 0
Line 4: vc2(ha+hb)+v2(ho)=H? 243 1700 1943 lbf
Design Summary*
Req. Sheathing Capacity 486 plf SW4 4-Term Deflectionj 0.299 in. 3-Term Deflection 0.320 in.
Req. Strap Force 1548 lbf CS 1 6 4-Term Story Drift %1 0.012 % 3-Term Story Drift % 0.013 %
Req. HD Force (H) 1943 lbf (2)CS16
Req. Shear Wall Anchorage Force (vmj 243 pIf
.The Design Summary assumes that the shear wall is designed as blocked.
Project Information 310 Daley Second Floor West shearwalls at end units
Code: Date:
Client:
Wall Line:
Shear Wall Deflection Calculation Variables
Unfactored Shear Load V,,,,f—red: 5000 (Ibf)
Sheathing Type:
Grade:1
Gt Override:
G. Override:
Wood
Species:
E:j
Dimensions!j
A:
A Override:
End Post Values:
HF
1.30E+06 (psi)
City Stud Size
2 1 2x6
16.5 (in.')
(in .z )
Nail Type: 8d common
Pier 1
Nail Spacing:
HD Ca pacity:
HD Deflection:
(penny weight)
Pier 2
2
3410
0.1
(in.)
(Ibf)
(in.)
1 7/16 OSB
APA Rated Sheathing
Four -Term Equation Deflection Check
A s -i ° A t 0.75he,,* d, a (FEW 23-2A
Vunfnt—d:
E:
h:
A:
Gt:
Nail Spacing:
V,,:
e,,:
b:
HD Capacity:
HD Defl:
Pier 1-L
Pier 1-R
Pier 2-L
Pier 2-R
625
625
625
625
1.30E+06
1.30E+06
1.30E+06
1.30E+06
8.00
5.00
5.00
8.00
16.5
16.5
16.5
16.5
83,500
83,500
83,500
83,500
2
2
2
2
104
104
104
104
0.0056
0.0056
0.0056
0.0056
3.75
3.75
4.25
4.25
3410
3410
3410
3410
0.1
0.1
0.1
0.1
Check Total Deflection of Wall System
(plf)
(psi)
(ft)
(in 2)
(Ibf/in.)
(in.)
(plf)
(in.)
(ft)
(Ibf)
(in.)
Sheathing Type: 7/16 OSB APA Rated Sheathing
Nail Type: 8d common
Pier 1 (left)
Pier 1 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-1
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-2
0.032
0.060
1 0.034
0.313
0.008
0.037
0.021
0.122
Sum
0.438
Sum
0.188
Pier 2 (left)
Pier 2 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-1
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-2
0.007
0.037
1 0.021
0.108
0.028
0.060
0.034
0.276
Sum
0.173
Sum
0.398
Tota I
Defl.
0.299 (in.)
0.0125 %drift
Project Information 310 Daley Second Floor West shearwalls at end units
Code:
Designer:
Client:
Project:
Wall Line:
Shear Wall Deflection Calculation Variables
Date:
Unfactored Shear Load V„nf--d: 5000 (Ibf)
Wood End Post Values:
Sheathi ng Type: 1 7/16 OSB Species: HF Nail Type: Sd common (pennyweight)
Grade:1 APA Rated Sheathing E:l 130E+06 (psi)
City Stud Size Pier 1 Pier 2
GtOverride: Diniensions!l 2 2x6 Nail Spacing:
G. Override: A: 16.5 (in•z) HD Capacity:
A Override: in .2) HD Deflection:
Three -Term Equation Deflection Check
,x:, p k )
E ' 1 INN b
Vunfnt—d:
E:
h:
A:
G,:
b:
HD Capacity:
HD Defl:
Pier 1-L
Pier 1-11
1 Pier 2-L
Pier 2-R
625
625
625
625
130E+06
130E+06
130E+06
130E+06
8.00
5.00
5.00
8.00
16.5
16.5
16.5
16.5
42.0
42.0
42.0
42.0
3.75
3.75
4.25
4.25
3410
3410
3410
3410
0.1
0.1
0.1
0.1
rl—k T—I nofl—i— of tN�ll r--
A
psi)
ft)
in?)
,kips/in.)
ft)
Ibf)
in.)
2
2
3410
3410
0.1
0.1
Sheathing Type: 7/16 OSB APA Rated Sheathing
Nail Type: 8d common
Pier 1 (left)
Pier 1 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 1
Bending
Term 2
Shear
Term 3
Fastener
0.032
0.119
0.313
0.008
1 0.074
0.122
Sum
0.464
Sum
0.204
Pier 2 (left)
Pier 2 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 1
Bending
Term 2
Shear
Term 3
Fastener
0.007
0.074
0.108
0.028
1 0.119
0.276
Sum
0.189
Sum
0.423
Tota I
Defl.
0320 (in.)
0.0133 %drift
Comment: The 3-term equation is calibrated to be approximately equal to 4-term equation at 1.4*ASD capacity.
(in.)
(Ibf)
(in.)
Project Information 310 Daley Second Floor West shearwalls at center units
Code: Date:
Designer:
Client:
Project:
Wall Line:
Ll(ft)
V (lb)
Lol(ft) L2(ft)
P
x
c
L. N(ft)
Shear Wall Calculation Variables
VL
20001bf
Opening 1
Adj. Factor Meth
Ll
2.67 ft
ha
1.00 ftj
Wall Pier Aspect Rat!
L21
2.00 ft
ho
4.00 ft
Pl=h L1= 1.50
h..,,8.00
ft
hb
3.00 ft
P2=hJL2= 2.00
Lwau
10.67 ft
Lol
6.00 ft
1. Hold-down forces: H = Vhw,ii/L„„ ii 1500 lbf
2. Unit shear above + below opening
First opening: val = vb1 = H/(ha+hb) = 375 plf
3. Total boundary force above + below openings
First opening: 01=valx(Lol)= 2249 lbf
4. Corner forces
F1=01(Ll)/(L1+L2)= 1286 lbf
F2 = 01(L2)/(Ll+L2) = 963 lbf
S. Tributary length of openings
T1 = (L1*Lol)/(Ll+L2) = 3.43 ft
T2 = (L2*Lol)/(Ll+L2) = 2.57 ft
6. Unit shear beside opening
N/A
v1= (V/L)(Ll+T1)/L1 =
428 plf
v2 = (V/L)(T2+L2)/L2 =
428 alf
Check vl*Ll+v2*L2=V?
2000 lbf OK
7. Resistance to corner forces
R1=v1*L1= 1143 lbf
R2=v2*L2= 8571bf
8. Difference corner force + resistance
RI-F1= -143 lbf
R2-F2= -107 lbf
9. Unit shear in corner zones
vc1 = (RI-F1)/L1 = -53 plf
vc2 = (R2-F2)/L2 = -53 plf
Check Summary of Shear Values for One Opening
Line 1: vc1(h,+hb)+v1(ho)=H? -214 1713 1500 lbf
Line 2: va1(h,+hb)-vc1(h,+hb)-v1(ho)=0? 1500 -214 1713 0
Line 3: va1(h,+hb)-vc2(h,+hb)-v1(hj=0? 1500 -214 1713 0
Line 4: vc2(ha+hb)+v2(h,)=H? -214 1713 1500 lbf
Design Summary*
Req. Sheathing Capacity
428 plf
SW4 4-Term Deflectionj
0.516 in.
3-Term Deflection
0.523 in.
Req. Strap Force
1286 lbf
CS 16 4-Term Story Drift %1
0.021 %
3-Term Story Drift %1
0.022
Req. HD Force (H)
1500 lbf
(2)CS16
Req. Shear Wall Anchorage Force (vma,)
187 plf
no hd req'd at party walls
*The Design Summary assumes that the shear wall is designed as blocked.
Project Information 310 Daley Second Floor West shearwalls at center units
Code: Date:
Client:
Wall Line:
Shear Wall Deflection Calculation Variables
Unfactored Shear Load V,,,,f—red: 2857 (Ibf)
Sheathing Type:
Grade:1
Gt Override:
G. Override:
Wood
Species:
E:j
Dimensions!j
A:
A Override:
End Post Values:
HF
1.30E+06 (psi)
City Stud Size
2 1 2x6
16.5 (in.')
(in .z )
Nail Type: 8d common
Pier 1
Nail Spacing:
HD Ca pacity:
HD Deflection:
(penny weight)
Pier 2
3
3410
0.1
(in.)
(Ibf)
(in.)
1 7/16 OSB
APA Rated Sheathing
Four -Term Equation Deflection Check
A s -i ° A t 0.75he,,* d, ft (FEW 23-2A
Vunfnt—d:
E:
h:
A:
Gt:
Nail Spacing:
V,,:
en:
b:
HD Capacity:
HD Defl:
Pier 1-L
Pier 1-R
Pier 2-L
Pier 2-R
612
612
612
612
1.30E+06
1.30E+06
1.30E+06
1.30E+06
8.00
5.00
5.00
8.00
16.5
16.5
16.5
16.5
83,500
83,500
83,500
83,500
3
3
3
3
153
153
153
153
0.0179
0.0179
0.0179
0.0179
2.67
2.67
2.00
2.00
3410
3410
3410
3410
0.1
0.1
0.1
0.1
Check Total Deflection of Wall System
(plf)
(psi)
(ft)
(in?)
(Ibf/in.)
(in.)
(plf)
(in.)
(ft)
(Ibf)
(in.)
Sheathing Type: 7/16 OSB APA Rated Sheathing
Nail Type: 8d common
Pier 1 (left)
Pier 1 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-1
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-2
0.044
0.059
1 0.107
0.430
0.011
0.037
0.067
0.168
Sum
0.640
Sum
0.282
Pier 2 (left)
Pier 2 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-1
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 4
HD-2
0.014
0.037
1 0.067
0.224
0.058
0.059
0.107
0.574
Sum
0.342
Sum
0.799
Tota I
Defl.
0.516 (in.)
0.0215 %drift
Project Information 310 Daley Second Floor West shearwalls at center units
Code: Date:
Designer:
Client:
Project:
Wall Line:
Shear Wall Deflection Calculation Variables
Unfactored Shear Load V„nf--d: 2857 (1bf)
Wood End Post Values:
Sheathi ng Type: 1 7/16 OSB Species: HF Nail Type: Sd common (pennyweight)
Grade:l APA Rated Sheathing E:l 130E+06 (psi)
City Stud Size Pier 1 Pier 2
GtOverride: Diniensions!l 2 2x6 Nail Spacing:
G. Override: A: 16.5 (in•z) HD Capacity:
A Override: in .2) HD Deflection:
Three -Term Equation Deflection Check
,x:, p �k )
E ' I INNAb
Vunfnt.red:
E:
h:
A:
G,:
b:
HD Capacity:
HD Defl:
Pier 1-L
Pier 1-11
1 Pier 2-L
Pier 2-R
612
612
612
612
130E+06
130E+06
130E+06
130E+06
8.00
5.00
5.00
8.00
16.5
16.5
16.5
16.5
28.0
28.0
28.0
28.0
2.67
2.67
2.00
2.00
3410
3410
3410
3410
0.1
0.1
0.1
0.1
rl—k T—I nofl—i— of tN�ll r--
PIS
psi)
ft)
in 2)
,kips/in.)
ft)
Ibf)
in.)
3
3
3410
3410
0.1
0.1
Sheathing Type: 7/16 OSB APA Rated Sheathing
Nail Type: 8d common
Pier 1 (left)
Pier 1 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 1
Bending
Term 2
Shear
Term 3
Fastener
0.044
0.175
0.430
0.011
1 0.109
0.168
Sum
0.649
Sum
0.288
Pier 2 (left)
Pier 2 (right)
Term 1
Bending
Term 2
Shear
Term 3
Fastener
Term 1
Bending
Term 2
Shear
Term 3
Fastener
0.014
0.109
0.224
0.058
0.175
0.574
Sum
0.348
Sum
0.807
Tota I
Defl.
0.523 (in.)
0.0218 %drift
Comment: The 3-term equation is calibrated to be approximately equal to 4-term equation at 1.4*ASD capacity.
(in.)
(lbf)
(in.)