SEE REV1 BLD FIR ENG RESUB 4-BLD2022-1329+Architectural_Plan+8.26.2024_12.31.54_PM+4462412City Of Edmonds
Building Department
Work 4 UNIT TOWNHOME
Address ; 306, 308, 310, 312 DALEY ST
___
Owner BUKOWSKI-310 DALEY TOWNHOMES
------ ----------
Approved Date 8/29/2024
Building Official ; 7)OW"VELK Vfk2«
Permit Number BLD2022-1325, 26, 27, 29
ABBREVIATIONS
@
AT
CENTERLINE
R
PROPERTY LINE
0
DIAMETER
#
POUND OR NUMBER
(E)
EXISTING
(N)
NEW
(X)
DEMOLISH
ABV
ABOVE
ACC
ACCESS
ACOUS ACOUSTICAL
................■.....■.......■.....■.....■....� AD AREA DRAIN
' The following documentation shall be available on ADJ ADJUSTABLE
site for the building inspector: - AFF ABOVE FINISHED FLOOR
' ■ AIB AIR INFILTRATION BARRIER
■ ' ALT ALTERNATE
x❑ ALUM ALUMINUM COE APPROVED ARCHITECTURAL PLAN SET APPROX APPROXIMATE
; ❑X COE APPROVED STRUCTURAL PLAN SET ARCH ARCHITECTURAL
❑ COE REVIEWED CALCULATION PACKET Bp BOARD
❑ ENERGY CREDIT WORKSHEET BLKG BLOCKING
BM BEAM
❑ SITE PLAN Bo BOTTOM OF
❑ CIVIL PLAN BOT BOTTOM
❑ CAB CABINET
' CB CATCH BASIN
■ ❑ - CEM CEMENT
■ CER CERAMIC
CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ CIP CAST -IN -PLACE
L ......... ■ ................... ■ . ■ ............... CJ CONTROL JOINT
CLG CEILING
APPROVED OBTAIN ELECTRICAL CLKG CAULKING
PLANS MUST BE PERMIT FROM CLO CLOSET
STATE LABOR & CLR CLEAR
ON JOB SITE INDUSTRIES CMU CONCRETE MASONRY UNIT
CNTR COUNTER
ALL WORK SUBJECT COL COLUMN
TO FIELD CONIC CONCRETE
INSPECTION FOR CONN CONNECTION
C
CODE COMPLIANCE T CONTINUOUS
CT CERAMIC TILE
CPT CARPET/CARPETED
CTR CENTER
■ Please obtain a separate Plumbing permit from the City of DBL DOUBLE
Edmonds. ■ DEMO DEMOLITION
OF DOUGLAS FIR
A deferred submittal is required for the exterior balconies. This i DIA DIAMETER
is to be submitted for review and approval by the City of DIM DIMENSION
Edmonds. ■
ON DOWN
��■�■�■�■�■�■�■�■�■� DO DOOR OPENING
■�■�■�■�■�■�■�■�■�■�■�� DR DOOR
' SPECIAL INSPECTION REPORT(SS) REQUIRED FOR THIS I DS DOWN SPOUT
PROJECT. PLEASE PROVIDE THE SI REPORT UPON REQUEST DTL DETAIL
,FROM THE BUILDING INSPECTOR. I DW DISHWASHER
I1. SOILS DWG DRAWING
E EAST
..�.�.�.�.�.�.�.�.�.�.�.�.�.�.�■ EA EACH
■ 1 EL ELEVATION
1 Building Envelope EF EXHAUST FAN
1)Pursuant to RCW 64.55, all applications for construction 1 ELEC ELECTRICAL
1 of multi -unit residential buildings must include building ELEV ELEVATOR
enclosure design documents that identify the building ENCL ENCLOSURE
• enclosure, including but not limited to, waterproofing, 1 EQ EQUAL
1 weather proofing and/or otherwise protected from water or EQUIP EQUIPMENT
■ 1 EST ESTIMATE
1 moisture intrusion. The building enclosure documents EXIST EXISTING
■ must contain a stamped statement by the person stamping 1 EXP EXPANDED/EXPANSION
the building enclosure design documents stating, in EXPO EXPOSED
1 EXT EXTERIOR
1 substantially the following form: "The undersigned has ■
provided building enclosure documents that in my 1 FD FLOOR DRAIN
■ professional judgment are appropriate to satisfy the FE FIRE EXTINGUISHER
1 requirements of RCW 64.55.005 through 64.55.090." FF FINISH FLOOR
■ 1 F-F FINISH TO FINISH
Additionally, all multi -unit residential buildings are required FIN FINISH
1 FLASH FLASHING
1 to have the building enclosure inspected by a qualified FLR FLOOR/FLOOR OPENING
building enclosure inspector during the course of 1 FLUOR FLUORESCENT
. construction. This inspection is to be completed by a third FOIC FURNISHED BY OWNER -
1 party, independent inspector. The City may not issue a INSTALLED BY CONTRACTOR
Certificate of Occupancy until the qualified, third art 1 FOC FACE OF CONCRETE
p y unq uaparty ■ FOM FACE OF MASONRY
■ independent inspector prepares a report and submits to 1 FOS FACE OF STUD
the building department a signed letter certifying that the FOF FACE OF FINISH
1 building enclosure has been inspected during the course of ! FIR FRAME
FIREPROOF
■ construction and that the construction is in substantial 1 F/P FIREPLACE
compliance with the building enclosure design documents. FT FOOT OR FEET
1 The requirement for third party inspection needs to be ■ FURR FURRING
specified on the plans. 1 FUT FUTURE
■ FW FULL WIDTH
1 Alternatively, a recorded "sale prohibition covenant" is GA GAUGE
required to be submitted for review. A "sale prohibition 1 GALV GALVANIZED
. covenant" is a recorded covenant that prohibits the sale or GC GENERAL CONTRACTOR
1 other disposition of individual dwelling units as or as part of GL GLASS
a condominium for five years or more from the date of first GLIJE-
GRAM GRADE LAMINATED
■ occupancy except as otherwise provided in section 10 of 1 GWB GYPSUM WALL BOARD
1 the act, a certified copy of which the developer shall submit '
to the appropriate building department; provided such ! HB HOSE BIB
■ covenant shall not apply to sales or dispositions listed in 1 HC HOLLOW CORE
RCW 64.34.400(2). The covenant shall be on a form HDO HIGH DENSITY OVERLAYHDR HEADER
1 provided by the City. ■ HDWD HARDWOOD
.�.�.�.�.�.�.�.�.�.�.�.�.�.�.�.� HDWR HARDWARE
HELOCK
APPROVED BY PLANNING HMM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
Sep 06 2024 HT HEIGHT
HTF HAMMER TO FIT
HVAC
s s o
HEATING/VENTILATION/
AIR CONDITIONING
HW
HOT WATER
ID
INSIDE DIAMETER
IN
INCH
IN UL
IN ULATI N
INT
INTERIOR
JB
JUNCTION BOX
JF. JT
JOINT FILLER, JOINT
LAM
LAMINATE/LAMINATED
LAV
LAVATORY
LF
LINEAR FEET
LOC
LOCATION
LP
LOW POINT
LT
LIGHT
MAS
MASONRY
MAX
MAXIMUM
MB
MACHINE BOLT
MC
MEDICINE CABINET
MOO
MEDIUM DENSITY OVERLAY
MECH
MECHANICAL
MEMB
MEMBRANE
MTL
METAL
MFR
MANUFACTURER
MIN
MINIMUM
MIR
MIRROR
MISC
MISCELLANEOUS
MTD
MOUNTED
MTRL
MATERIAL
MUL
MULLION
N
NORTH
N/A
NOT APPLICABLE
NIC
NOT IN CONTRACT
NO
NUMBER
NOM
NOMINAL
NR
NOISE REDUCTION
NITS
NOT TO SCALE
OA
OVERALL
OC
ON CENTER
OD
OUTSIDE DIAMETER
OFF
OFFICE
OH
OVERHEAD
OPNG
OPENING
OPP
OPPOSITE
PERF
PERFORATED
PERP
PERPENDICULAR
PL
PLATE
PLAM
PLASTIC LAMINATE
PLAS
PLASTER
PLYWD
PLYWOOD
PNL
PANEL
PR
PAIR
PRCST
PRE -CAST
PT
POINT
PTO
PAINTED
PTN
PARTITION
R
RISER
RA
RETURN AIR
RAD
RADIUS
RB
RUBBER BASE
RD
ROOF DRAIN
REF
REFERENCE
REFR
REFRIGERATOR
REINF
REINFORCED
REM
REMAINDER
REQ
REQUIRED
RESIL
RESILIENT
REV
REVISION/REVISED
RGSTR
REGISTER
RM
ROOM
RO
ROUGH OPENING
S
SOUTH
SAF
SELF -ADHERED FLASHING
SAM
SELF -ADHERED MEMBRANE
SC
SOLID CORE
SO
SMOKE DETECTOR
SCHED
SCHEDULE
SECT
SECTION
SF
SQUARE FEET
SG
SAFETY GLASS
SH
SHELF
SHT
SHEET
SHT MTL
SHEET METAL
SHTG
SHEATHING
SHWR
SHOWER
SIM
SIMILAR
SOG
SLAB ON GRADE
SPEC
SPECIFICATION
SI
SQUARE INCHES
SS
STAINLESS STEEL
STA
STATION
STD
STANDARD
STL
STEEL
STOR
STORAGE
STRUC
STRUCTURAL
SUSP
SUSPENDED
SYM
SYMBOL
T
TREAD
TB
TOWEL BAR
TIC
TOP OF CHORD
TEL
TELEPHONE
TER
TERRAZZO
T+G
TONGUE AND GROOVE
TG
TEMPERED GLASS
THK
THICK
TO
TOP OF
TOP
TOP OF PAVEMENT
TOS
TOP OF SLAB/STEEL
TPH
TOILET PAPER HOLDER
TYP
TYPICAL
111l104[■�ll0u*&1104[■ir:1Bill ra:1:17i919:
VB
VAPOR BARRIER
VCT
VINYL COMPOSITION TILE
VEN
VENEER
VERT
VERTICAL
VT
VINYL TILE
W
WEST
WC
WATER CLOSET
WD
WOOD
WF
WIDE FLANGE
WG
WIRED GLASS
WH
WATER HEATER
WL
WATER LINE
W/O
WITHOUT
WIN
WINDOW
WP
WATERPROOF
WR
WATER RESISTANT
WSG
WIRE SAFETY GLASS
WT
WEIGHT
SYMBOLS LEGEND
1: BUILDING ELEVATIONS
2: INTERIOR ELEVATIONS
0
A0.0 OR SECTIONS
3: ASSEMBLY REFERENCE W�
4: WALL SECTIONS/
DETAIL REFERENCE 0
Ao.O
AREA MAP
0
A0.0
BLD2022-1325 - 308 DALEY - LOT B
0 BLD2022-1326 - 310 DALEY - LOT C
y
BLD2022-1327 - 312 DALEY - LOT D
BLD2022-1329 - 306 DALEY - LOT A
L
uO
CD
BELLEVUE
1
aNTS
US-2
Approved
DFM ohrisswt
South County Fire
Date: 08/27/2024
08-27-2024
RESUB 4 PLAN REVIEW
NOTES: APPROVED WITH CONDITIONS:
1. A SEPARATE PERMIT SUBMITTAL IS
REQUIRED FOR EACH TOWNHOME
UNIT 13D SPRINKLER SYSTEM. A
RECOMMENDED FLOW -THROUGH
DESIGN WILL MEET SPECIFICATIONS
D EDUCE EQUIPMENT AND
CONTI UAIAS
MAINTENANCE
REQUIR . ROVIDE A MINIMUM
COMBINA ION WATER SERVICE OF
ONE I (1 ") METER A ONE AND
ON ALF (1 1/2") SERVICE LINE OR
OW THAT THE DOMESTIC AND FIRE
PROTECTIONS NEEDS CAN BE MET
WITH A SMALLER SERVICE.
2.4 INCH ADDRESS LETTER
CHARACTERS WITH 1/2 INCH STROKE
TO BE INSTALLED NEAR THE MAIN
ENTRANCE DOOR TO EACH
TOWNHOME. 6 INCH ADDRESS
NUMBER CHARACTORS WITH 1/2"
STROKE IN CONTRASING COLOR TO
THIER BACKGROUND AND VISIBLE
FROM THE STREET TO BE INSTALLED.
DFM BURT
VICINITY MAP a NTS
PUGET SOUND
PROJECT DIRECTORY
OWNER AND DEVELOPER
HBRE INVESTMENTS
1951 3RD AVENUE W
SEATTLE, WA 98119
DESIGNER AND APPLICANT
CITIZEN DESIGN
10 DRAVUS STREET
SEATTLE, WA 98109
CONTACT: JACOB YOUNG
TEL: 206.853.8055
EMAIL: JYOUNG@COLLABORATIVECO.COM
STRUCTURAL ENGINEER
BUILT ENGINEERING
534 BROADWAY #305
TACOMA, WA 98402
CONTACT: BRICE PARRISH
TEL: 253.985.5008
EMAIL: BRICE@BUILTSTRUCTURAL.COM
CIVIL ENGINEER
DAVIDO CONSULTING GROUP
15029 BOTHELL WAY NE #600
LAKE FOREST PARK, WA 98155
CONTACT: TIM GABELEIN, PE
TEL: 206.523.0024
EMAIL: TIM@DCGENGR.COM
SURVEY
CHADWICK + WINTERS
1422 NW 85TH STREET
SEATTLE, WA 98117
CONTACT: BRANDON WINTERS
TEL: 206.297.0996
EMAIL: BRANDONW@CHADWICKWINTERS.COM
LANDSCAPE ARCHITECT
CRAMER DESIGN CONSULTANTS
1909 242ND STREET SE
BOTHELL, WA 98021
CONTACT: GAYLE CRAMER
TEL: 425.241.6258
EMAIL: CDCLSA@FRONTIER.COM
ARBORIST
LAYTON TREE CONSULTING
PO BOX 572
SNOHOMISH, WA 98291
CONTACT: BOB LAYTON
TEL: 425.220.5711
EMAIL: BOB@LAYTONTREECONSULTING.COM
GENERAL CONTRACTOR
SEATTLE LUXURY HOMES, LLC
PO BOX 1478
EDMONDS, WA 98020
LIC. NO.: SEATTLH822JB
CONTACT: JOHNATHAN KURTH
T: 206.579.5272
E: JOHNATHAN.KURTH@GMAIL.COM
SHEET INDEX
ARCHITECTURAL
A0.0
PROJECT INFORMATION
A0.1
ARCHITECTURAL GENERAL NOTES
A0.2
ENERGY CODE ANALYSIS: UNITS A AND B
A0.3
ENERGY CODE ANALYSIS: UNITS C AND D
A0.4
ENERGY CODE COMPLIANCE: ALL UNITS
A0.5
ZONING SITE PLAN
A1.1
ARCHITECTURAL SITE PLAN
1 OF 1
SURVEY
A1.2
VICINITY MAP
A1.3
CONCEPTUAL LIGHTING PLAN
A2.1
FIRST FLOOR PLAN
A2.2
SECOND FLOOR PLAN
A2.3
THIRD FLOOR PLAN
A2.4
ROOF PLAN
A3.1
ELEVATIONS
A3.2
ELEVATIONS
A3.3
ELEVATIONS
A3.4
RENDERED ELEVATIONS
A3.5
RENDERINGS
A3.6
RENDERINGS
A4.1
SECTIONS AND ASSEMBLIES
A4.2
SECTIONS AND ASSEMBLIES
A4.3
SECTIONS AND ASSEMBLIES
A5.1
WALL SECTIONS
A5.2
DETAILS
A5.3
DETAILS
A5.4
DETAILS
STRUCTURAL
S1.0
GENERAL STRUCTURAL NOTES
S2.0
FOUNDATION PLAN
S2.1
SECOND FLOOR FRAMING PLAN
S2.2
THIRD FLOOR FRAMING PLAN
S2.3
ROOF FRAMING PLAN
S3.0
STRUCTURAL DETAILS
S3.1
STRUCTURAL DETAILS
S3.2
STRUCTURAL DETAILS
S4.0
STRUCTURAL DETAILS
PROJECT INFORMATION
SCOPE OF WORK
CONSTRUCT (4) TOWNHOUSES TOTAL. (2) TOWNHOUSES TO
CONTAIN 1774± SF LIVING AREA AND 383± SF GARAGE (EA.) AND
(2) TOWNHOUSES TO CONTAIN 1407± SF LIVING AREA AND 303± SF
GARAGE (EA.). CONSTRUCT SITE IMPROVEMENTS INCLUDING BUT
NOT LIMITED TO STORM DRAINAGE, WALKWAYS AND SITE STAIRS.
(E) DUPLEX TO BE DEMOLISHED UNDER SEPARATE PERMIT.
ESTABLISH USE AND OCCUPY, PER PLANS.
SITE ADDRESS
310 DALEY STREET
EDMONDS, WA 98020
ZONING AND LAND AREA
ZONING: BD-2
LOT AREA: 7500 SF
PARCEL MAP NUMBER
004342-026-001-01
LEGAL DESCRIPTION
LOTS 1, 2, 3, AND 4, BLOCK J, CITY OF EDMONDS, ACCORDING TO
THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 39,
RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
EXCEPT THE SOUTH 60 FEET THEREOF.
JURISDICTION
EDMONDS, SNOHOMISH COUNTY, WASHINGTON
BUILDING INFORMATION
OCCUPANCY: R-3 (TOWNHOUSES)
CONSTRUCTION: VB
FIRE SUPPRESSION: NFPA 13D THROUGHOUT
M
SEPA COMPLIANCE I
APPLICABLE SEPA THRESHOLD IS (4) DWELLING UNITS. THIS
PROJECT CONTAINS (4) DWELLING UNITS AND IS CATEGORICALLY
EXEMPT FROM ENVIRONMENTAL REVIEW M
PROJECT NUMBERS M
UNIT A BUILDING PERMIT (THIS PERMIT): BLD2022-1329
UNIT B BUILDING PERMIT: BLD2022-1325
UNIT C BUILDING PERMIT: BLD2022-1326
UNIT D BUILDING PERMIT: BLD2022-1327
DEMOLITION PERMIT: BLD2022-1328
PRELIMINARY SHORT PLAT: PLN2023-0069
A
RIGHT -OF -WAY CONSTRUCTION: ENG2023-0473
DEFERRED SUBMITTALS M
REVISED STRUCTURAL DRAWINGS WILL BE SUBMITTED AFTER
PERMIT APPROVAL PER MIKE CLUGSTON AND LEIF BJORBACK.
LANDSCAPE
L-1 LANDSCAPE PLAN
Y
CIVIL (UNDER SEPARATE PERMIT) BLD2024-0804
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W
O
o
N
City of EDMONDS
Permit Set
October 7, 2022
C01 COVER SHEET
CO2 TESC + DEMO PLAN
CO3 GRADING PLAN
Revision 1
10/21/22
C04 ALLEY PLAN AND PROFILE
C05 DRAINAGE PLAN
COb UTILITY PLAN
2
Revision 2
04/03/23
C07 FRONTAGE IMPROVEMENT PLAN
C08 DETAILS
Revision 3
09/15/23
C09 DETAILS
C10 DETAILS
Revision 4
02/05/24
C11 DETAILS
Revision 5
06/10/24
DOCUMENTS
Revision b
08/22/24
STRUCTURAL CALCULATIONS
DRAINAGE REPORT
ENGINEERING DIVISION
APPROVED AS NOTED
14 9/11 /2024
REFER TO APPROVED CIVIL
CONSTRUCTION PLANS FOR
ENGINEERING REQUIREMENTS.
FOR PLANNING DEPT USE ONLY
PROJECT
INFORMATION
SCALE: AS NOTED
A000
ARCHITECTURAL GENERAL NOTES
GARAGE NOTES
ELECTRICAL NOTES
MECHANICAL & ENERGY NOTES
1. ALL WORK SHALL BE IN CONFORMANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), 2018 WASHINGTON
STATE ENERGY CODE (WSEC), THE KING COUNTY SURFACE WATER DESIGN MANUAL (SWDM), EDMONDS COMMUNITY
DEVELOPMENT CODE (ELDC), WA. ADMINISTRATIVE CODE (WAC). UNIFORM PLUMBING CODE (UPC), AND WA VENT &
INDOOR AIR QUALITY CODE (VIAQ).
2. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS TO BE LEFT IN CLEAN (BROOM) CONDITIONS
AT ALL TIMES.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME FULLY AWARE OF ANY AND ALL CONDITIONS RELATED TO
THE SITE AND EXISTING CONDITIONS THAT MAY AFFECT THE COST OR SCHEDULING OF CONSTRUCTION ACTIVITIES
PRIOR TO SUBMITTING BID.
4. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE
INCLUDING, BUT NOT LIMITED TO. SOILS AND EXISTING UTILITIES AND SHALL BE RESPONSIBLE FOR THE SAME. ALL
DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT AND/OR DESIGNER & OWNER IMMEDIATELY.
5. THE CONTRACTOR IS TO VERIFY THE LOCATION OF ALL UTILITIES AND SERVICES TO THE SITE PRIOR TO BEGINNING
ANY SITE IMPROVEMENTS.
6. THERE SHALL BE NO DEVIATION WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S
AND/OR DESIGNER'S WRITTEN APPROVAL THEREOF, CHANGE ORDER OR CHANGE DIRECTIVE.
7. DO NOT SCALE DRAWINGS OR DETAILS - USE GIVEN DIMENSIONS, CHECK DETAILS FOR LOCATION OF ALL ITEMS NOT
DIMENSIONED ON PLANS, DOOR AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE SIX (6) INCHES FROM FACE
OF ADJACENT WALL OR CENTERED BETWEEN WALLS UNLESS NOTED OTHERWISE.
8. THE DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION
SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER.
9. BUILDING SYSTEMS AND COMPONENTS NOT SPECIFICALLY DETAILED SHALL BE INSTALLED, AS PER MINIMUM
MANUFACTURER'S RECOMMENDATIONS. NOTIFY THE ARCHITECT OF ANY RESULTING CONFLICTS.
10. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF ANY CONFLICT
WHEREIN THE METHODS OR STANDARDS OF INSTALLATION, OR THE MATERIALS SPECIFIED, DO NOT EQUAL OR
EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN.
11. INSTALL DUST BARRIERS AND OTHER PROTECTION AS REQUIRED TO PROTECT INSTALLED FINISHES AND FACILITIES.
12. PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO ARCHITECTURAL DRAWINGS, IT
SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK WITH THE ARCH. DRAWINGS BEFORE INSTALLATION
OF THEIR WORK. ANY DISCREPANCY BETWEEN ARCH. DRAWINGS AND THE CONSULTING ENGINEER(S) OR OTHER
SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE OWNER'S ATTENTION IN WRITING.
13. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL AND LOCAL GLAZING STANDARDS AND THE
GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE REQUIREMENTS, IF THE GLAZING
SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARDS, HE OR SHE
SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING.
14. ALL GLAZING IN HAZARDOUS LOCATIONS, DEFINED BY THE 2018 IRC R308.4, SHALL BE SAFETY GLAZING, INCLUDING
BUT NOT LIMITED TO THE SAFETY GLAZING IDENTIFIED IN THE CONSTRUCTION DOCUMENTS.
15. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR
FURRED AND FINISHED, UNLESS NOTED AS EXPOSED CONSTRUCTION TO THE DRAWINGS. OFFSET STUDS WHERE
REQUIRED, SO THAT FINISHED WALL SURFACE WILL BE FLUSH.
16. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL
ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS.
17. CARRY ALL FOOTINGS TO SOLID, UNDISTURBED ORIGINAL EARTH. REMOVE ALL UNSUITABLE MATERIAL UNDER
FOOTINGS AND SLAB AND REPLACE WITH CONCRETE OR WITH COMPACTED FILL AS DIRECTED BY A GEO-TECHNICAL
ENGINEER.
18. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF
THE 2018 IRC.
19. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR EXPOSED WEATHER SHALL BE PRESSURE TREATED WITH AN
APPROVED PRESERVATIVE UNLESS DECAY RESISTANT HEARTWOOD OF CEDAR OR REDWOOD IS USED, FASTENERS
FOR PRESSURE TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICONE, BRONZE
OR COPPER.
20. ALL WOOD LESS THAN 6 INCHES FROM THE GROUND OR 2 INCHES MEASURED VERTICALLY FROM EXTERIOR
CONCRETE STEPS, PORCH SLABS, PATIO SLABS, AND SIMILAR HORIZONTAL SURFACES EXPOSED TO WEATHER SHALL
BE A NATURALLY DURABLE WOOD OR PRESSURE TREATED WITH AN APPROVED PRESERVATIVE PER 2018 IRC R317.
21. PROVIDE FIRE -BLOCKING VERTICALLY AT CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT
EXCEEDING 10 FEET AND AS REQUIRED FOR CONCEALED SPACES UNDER 2018 IRC 502.13 & R602.8.
22. NAIL GYPSUM WALLBOARD TO ALL STUDS, TOP PLATES, BOTTOM PLATES AND BLOCKING WITH COOLER NAILS @ 7
INCHES O.C. MAXIMUM SPACING UNLESS SHOWN OTHERWISE. USE 5d FOR 1/2" WALLBOARD AND 6D FOR 5/8"
WALLBOARD.
23. PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS.
24. STRUCTURAL, ELECTRICAL, MECHANICAL AND ENERGY NOTES ARE LOCATED WITHIN THIS SET OF DRAWINGS.
25. NO MATERIALS FROM THE WORK ARE TO BE STOCK PILED ON THE PUBLIC RIGHTS -OF WAYS. ALL RUBBISH AND
DEBRIS IS TO BE REMOVED FROM THE SITE.
26. ADJACENT PROPERTIES. STREETS AND WALKS ARE TO BE PROTECTED FROM DAMAGE AT ALL TIMES.
27. ALL DOWNSPOUTS AND ROOF DRAINS ARE TO BE CONNECTED TO THE POINT OF DISCHARGE SPECIFIED ON THE
DRAINAGE PLAN AND/OR SITE PLAN BY TIGHTLINE UNLESS NOTED OTHERWISE IN CONSTRUCTION DOCUMENTS.
28. ALL DIMENSIONS ARE FACE OF STUD WALL, CENTER LINE OF COLUMN, OR FACE OF CONCRETE UNLESS NOTED
OTHERWISE.
29. THE CONTRACTOR SHALL SECURE PERMITS REQUIRED BY THE FIRE DEPARTMENT PRIOR TO BUILDING OCCUPATION.
30. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND
WORKERS AT ALL TIMES DURING THE COURSE OF THE PROJECT.
31. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN.
32. THE CONTRACTOR AND/OR THE SUB -CONTRACTOR SHALL APPLY FOR, OBTAIN AND PAY FOR ALL REQUIRED PERMITS
AND FEES EXCEPT FOR THE BUILDING PERMIT.
33. ALL STAIRWAYS MUST MEET THE REQUIREMENTS OF 2018 IRC R311.7.
34. ALL EMERGENCY ESCAPES AND RESCUE OPENINGS FOR BEDROOMS AND BASEMENTS MUST MEET THE
REQUIREMENTS OF 2018 IRC R310.
35. ROOF VENTILATION MUST MEET THE REQUIREMENTS OF 2018 IRC R806.
36. CRAWL SPACE VENTILATION MUST MEET THE REQUIREMENTS OF 2018 IRC R408.
37. ALL SIDING METHODS MUST HAVE A WEATHER RESISTIVE BARRIER THAT MEETS THE REQUIREMENTS OF 2018 IRC
R703.2. GENERAL WEATHER PROTECTION FOR THE ENTIRE PROJECT MUST MEET THE REQUIREMENTS OF 2018 IRC
R903.
38. ALL GUARDRAILS FOR DECKS, BALCONIES, AND OPEN RAILINGS MUST MEET THE REQUIREMENTS OF 2018 IRC 312.
39. ALL SKYLIGHTS AND SLOPED GLAZING MUST MEET THE REQUIREMENTS OF 2018 IRC 308.6.
40. ALL CEILING HEIGHTS MUST MEET THE REQUIREMENTS OF 2018 IRC R305.
41. ALL UNDER FLOOR AND CRAWL SPACE MUST BE ACCESSIBLE PER 2018 IRC R408.4.
42. ATTIC ACCESS MUST BE SIZED AND LOCATED ACCESSIBLY PER 2018 IRC R807.1.
43. ALL SHOWERS SHALL BE FINISHED WITH A SMOOTH, NOT-ABSORBANT SURFACE TO 72" ABOVE THE DRAIN PER 2018
IRC SEC. 307.2
44. THRESHOLDS AT EGRESS - LANDINGS OR FLOOR AT THE REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1 z "
LOWER THAN THE TOP OF THRESHOLD.
GRADING NOTES
1. CONSTRUCTION EROSION CONTROL MEASURES MUST BE IN PLACE AND APPROVED BY LOCAL MUNICIPALITY PRIOR TO
ANY EARTH DISTURBANCE. CALL THE LOCAL MUNICIPALITY TO SCHEDULE AN INSPECTION APPOINTMENT.
2. NO SEDIMENT SHALL BE TRACKED INTO THE SITE OR ONTO PAVED SURFACES. SEDIMENT SHALL BE REMOVED FROM
TRUCKS AND EQUIPMENT PRIOR TO LEAVING THE SITE. IN THE EVENT THERE IS A FAILURE OF AN EROSION CONTROL
SYSTEM RESULTING IN SEDIMENT BEING TRACKED ONTO PAVED SURFACES, THE CONTRACTOR SHALL IMMEDIATELY
IMPLEMENT MEASURES TO CORRECT THE SITUATION, AND STREET SWEEPING SHALL BE EMPLOYED ON AN
EMERGENCY BASIS. IF STREET SWEEPING VEHICLES ARE UTILIZED, THEY SHALL BE OF THE TYPE THAT ACTUALLY
REMOVES SEDIMENT FROM THE PAVEMENT.
3. FOR SITES WITHIN AN ENVIRONMENTALLY CRITICAL AREA (ECA), GRADING MUST BE STABILIZED BY OCTOBER 31 ST
AND NO EXCAVATION OR FILL PLACEMENT TO BE PERFORMED BETWEEN OCTOBER 31STAND APRIL 1ST.
1. GARAGE SEPARATION SHALL BE PER 2018 IRC TABLE R302.6. GARAGES SHALL BE SEPARATED FROM THE LIVING
AREA AND ITS ATTIC AREA BY NOT LESS THAN %" GWB APPLIED TO THE GARAGE SIDE. GARAGES SHALL BE
SEPARATED FROM HABITABLE ROOMS ABOVE BY NOT LESS THAN %" TYPE X GWB. WHERE THE SEPARATION IS A
FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT
LESS THAN %" TYPE X GWB OR EQUIV.
2. OPENINGS BETWEEN GARAGE AND LIVING SPACE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1
%" THICK, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 4" THICK, OR 20-MINUTE FIRE -RATED
DOORS, EQUIPPED WITH A SELF CLOSING DEVICE.
3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARATING THE DWELLING FROM THE
GARAGE SHALL BE CONSTRUCTED OF A MIN NO.26 GAUGE SHEET STEEL OR OTHER APPROVED MATERIALS AND
SHALL HAVE NO OPENINGS INTO THE GARAGE PER 2018 IMC 302.5.2
4. IN SEISMIC DESIGN CATEGORIES D1 & D2, WATER HEATERS SHALL BE ANCHORED TO RESIST HORZ. DISPLACEMENT
DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE @ POINTS WITHIN THE UPPER ONE THIRD AND LOWER ONE
THIRD PER 2018 IMC M1307.2.
5. PROVIDE OUTDOOR COMBUSTION AIR FOR WATER HEATER.
6. GARAGE FLOOR SURFACES SHALL BE APPROVED NONCOMBUSTIBLE MATERIAL AND THE AREA USED FOR THE
PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO
A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY 2018 IMC R309.1.
7. GAS APPLIANCES LOCATED IN A GARAGE SHALL BE RAISED 18" MIN. ABOVE FINISHED FLOOR. G2408.2 (305.3)
PROVIDE COMBUSTION AIR (SEE SEC. 702, 703, 704, 705, IMC) EITHER ALL OUTDOOR AIR (MOST COMMON) OR IN
GARAGE (ALL INSIDE AIR).
8. APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM DAMAGE FROM VEHICLES PER 2018
IRC M1307.3.1.
LIVING AREA NOTES
1. ALL INTERIOR WALLS TO BE 2x4 @ 16" O.C. (U.N.O.), EXCEPTING PLUMBING WALLS.
2. ALL EXTERIOR WALLS TO BE 2x6 @ 16" O.C. (U.N.O.)
3. HEADERS PER STRUCTURAL (U.N.0)
4. PROVIDE FIREBLOCKING AT ALL PLUMBING OPENINGS.
5. PROVIDE SOLID BLOCKING OVER SUPPORTS.
6. WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR -CEILING
ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1000
SF. DRAFT STOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS AND SHALL BE
OF%" GYP BOARD OR OTHER APPROVED MATERIALS INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS PER
LOCAL RESIDENTIAL CODE.
7. PROVIDE FIRE -BLOCKING TO CUT OFF ALL CONCEALED HORIZONTAL AND VERTICAL DRAFT OPENINGS AND TO
FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE.
FIRE -BLOCKING SHALL CONSIST OF NOT LESS THAN 2" NOMINAL LUMBER OR OTHER APPROVED MATERIAL / LOCAL
RESIDENTIAL CODE.
8. ASPHALT -SATURATED FELT FREE FROM HOLES OR BREAKS, WEIGHTING NOT LESS THAN 14 POUNDS PER 100 SF
AND COMPLYING WITH ASTM D 226 OR OTHER APPROVED WEATHER RESISTANT MATERIAL SHALL BE APPLIED
OVER SHEATHING OF ALL EXTERIOR WALLS. APPROVED ALTERNATE WEATHERPROOF MEMBRANES SHALL BE
USED FOR OPEN JOINT RAIN SCREEN SIDING. WEATHER RESISTANT MATERIALS SHALL BE APPLIED HORIZONTALLY
PER MANUFACTURERS RECOMMENDATIONS, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS
THAN 2 INCHES AND NOT LESS THAN 6" WHERE JOINTS OCCUR/ LOCAL RESIDENTIAL CODE.
9. APPROVED CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A
MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDINGS
SURFACE AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING THE EXTERIOR WALL ENVELOPE.
10. FLASHING SHALL BE INSTALLED BUT NOT LIMITED TO THE FOLLOWING LOCATIONS:
- THE TOP OF ALL EXTERIOR WINDOW & DOOR OPENINGS
- INTERSECTIONS OF FRAME WALLS AND MASONRY OR STUCCO
- UNDER MASONRY, WOOD OR METAL COPINGS AND SILLS
- CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM
- WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A HALF WALL
- AT WALL AND ROOF OR SOFFIT INTERSECTIONS
- AT BUILT-IN GUTTERS
ROOF NOTES
1. SHADED AREAS INDICATE OVERFRAMING, 2x6 @ 24" O.C. TYPICAL
2. SOFFIT, VENT, AND INSULATE ALL CANTILEVERED AREAS
3. PROVIDE SOLID BLOCKING OVER SUPPORTS
4. CIS - DOWNSPOUTS (4" SOLID PIPE TIGHTLINED INDEPENDENT OF FOOTING DRAIN)
5. ALL MANUFACTURED TRUSSES:
- SHALL HAVE DESIGN DETAILS AND DRAWINGS ON SITE FOR FRAMING INSPECTION
- SHALL BE INSTALLED AND BRACED TO MANUFACTURER'S SPECIFFICATIONS
- SHALL CARRY MANUFACTURER'S STAMP ON EACH TRUSSES
6. FLASHINGS SHALL BE INSTALLED IN SUCH A MANNER AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF
THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH
PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. METAL FLASHING SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.0019" / LOCAL RESIDENTIAL CODE.
7. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH
NO LESS THAN THE THICKNESS OF THE PARAPET WALL.
8. WHERE ROOF DRAINS ARE REQUIRED, OVERFLOW DRAINS HAVING THE SAME SIZE AS THE ROOF DRAINS SHALL BE
INSTALLED PER LOCAL RESIDENTIAL CODE & THE INTERNATIONAL PLUMBING CODE.
FRAMING NOTES
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE DRAWINGS, NOTES,
SPECIFICATIONS, AND ALL APPLICABLE CODES AND ORDINANCES.
2. ALL FRAME CONSTRUCTION SHALL CONFORM TO MIN STANDARDS OF IBC/IRC. FASTENING REQUIREMENTS TO BE IN
ACCORDANCE TO IBC. SEE STRUCTURAL DRAWINGS GENERAL NOTES AND SPECIFICATIONS FOR ANY OTHER NOTES
THAT MAY RELATE SPECIFICALLY TO GRADES AND SIZING OF ALL FRAMING MEMBER.
3. COLUMNS AND POSTS LOCATED ON CONCRETE OR MASONRY FLOORS OR DECKS EXPOSED TO THE WEATHER OR TO
WATER SPLASH OR IN BASEMENT AND WHICH SUPPORT PERMANENT STRUCTURES SHALL BE SUPPORTED BY
CONCRETE PIERS OR METAL PEDESTALS PROJECTING ABOVE FLOORS UNLESS APPROVED WOOD OR NATURAL
RESISTANCE TO DECAY OR TREATED WOOD IS USED. THE PEDESTALS SHALL PROJECT AT LEAST 6" ABOVE EXPOSED
EARTH AND AT LEAST 1" ABOVE SUCH FLOORS.
4. ALL WOOD OR WOOD PRODUCTS EXPOSED TO WEATHER OR IN DIRECT CONTACT WITH CONCRETE SHALL BE
PROTECTED AGAINST DECAY PER 2018 IRC R317.
5. MAINTAIN ALL INTEGRITY OF REQUIRED ONE HOUR SEPARATION BETWEEN DIFFERENT OCCUPANCYTYPES. SEE
DRAWINGS AND DETAILS FOR REQUIRED ONE AND TWO HOUR PARTY WALLS BETWEEN UNITS. - GARAGE/
DWELLING PER 2018 IRC R302.5 & 302. 6
6. WHERE INSTALLATION INCLUDES MANUFACTURED PRODUCTS, COMPLY WITH THE MANUFACTURER'S APPLICABLE
INSTRUCTIONS AND RECOMMENDATIONS FOR INSTALLATION. VERIFY ROUGH -IN DIMENSIONS FOR EQUIPMENT AND
PROVIDE BUCK -OUTS, BACKING AND JACKS AS REQUIRED.
7. ALL GUARDRAILS PER 2018 IRC R312 TO BE 36" HIGH MINIMUM FROM FINISHED FLOOR LINE. OPENINGS IN RAILING
ASSEMBLIES ARE NOT TO EXCEED 4" IN ONE DIRECTION. GUARDRAILS AND HANDRAILS TO WITHSTAND A 200 LB/SF
CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP. GUARD IN -FILL COMPONENTS
(ALL THOSE EXCEPT THE HANDRAIL), BALUSTERS AND PANEL FILLERS SHALL BE DESIGNED TO WITHSTAND A
HORIZONTALLY APPLIED NORMAL LOAD OF 50 LBS ON AN AREA EQUAL TO 1 SQ.FT. THIS LOAD NEEDS TO ASSUMED
TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD REQUIREMENTS. HANDRAILS TO BE BETWEEN 1-%" DIA. AND
2" DIA. WITH CLEARANCE OF 1-%' BETWEEN RAIL AND WALL SURFACE, MOUNT BETWEEN 34" AND 38" OFF STAIR
NOSING.
8. DECKING: ALL WOOD EXPOSED TO WEATHER, SUCH AS WOOD USED FOR DECK FRAMING INCLUDING DECKING,
RAILINGS, JOISTS, BEAMS, AND POSTS SHALL BE PRESSURE TREATED OR OF WOOD WITH NATURAL RESISTANCE
TO DECAY.
9. UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FACE OF STUDS, FACE OF FOUNDATION WALLS, CENTERLINE OF
COLUMNS, CENTERLINE OF DOORS AND WINDOWS. WHEN EXTERIOR WALLS ARE DIMENSIONED 6 THEY INCLUDE
%" SHEATHING OVER 2x6 STUDS @ 16" O.C.
1. ALL ELECTRICAL WORK IS TO BE DESIGNED BY THE SUBCONTRACTOR AND COMPLETED PER APPLICABLE CODES
AND ORDINANCES, INCLUDING BUT NOT LIMITED TO THE CODES REFERENCED IN ARCHITECTURAL GENERAL NOTE
#1.
2. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS RELATED TO THE PARTY'S SCOPE
OF WORK.
3. WIRING METHODS SHALL BE AS PERMITTED BY "CODE" AND INSTALLATION PER "NECA" STANDARDS.
4. USE OF ALUMINUM WIRE IS LIMITED TO SIZE #4 AND LARGER.
5. ALL DEVICES TO BE SPECIFICATION GRADE.
6. ALL NEW ELECTRICAL PANELS OR LOAD CENTERS TO BE PROTECTED ON LINE SIDE BY CURRENT LIMITING FUSES.
7. ALL RECEPTACLES SHALL BE AT LEAST 15 INCHES FROM FINISHED FLOOR TO BOTTOM OF BOX UNLESS NOTED
OTHERWISE.
8. ALL SWITCHES SHALL BE 42" FROM FINISHED FLOOR TO BOTTOM OF BOX UNLESS NOTED OTHERWISE.
9. LOCATE RECEPTACLES PER 2018 IRC SEC E3801.
10. VERIFY ALL RECEPTACLES, SWITCH, AND FIXTURE LOCATIONS WITH OWNER PRIOR TO INSTALLATION.
11. ALL EXTERIOR LIGHTING TO BE SHIELDED AND DIRECTED AWAY FROM ADJACENT PROPERTIES.
WHOLE -HOUSE VENTILATION SYSTEM
M1507.3.1 SYSTEM DESIGN.
EACH DWELLING UNIT OR GUEST ROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION
M1507.3.4, M1507.3.5, M1507.3.6, OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH
COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE.
M1507.3.2 CONTROL AND OPERATION.
1. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT.
2. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS. OR
OTHER APPROVED MEANS.
3. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS,
FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS.
CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER
ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE
HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)."
4. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING INTERMITTENTLY
AND CONTINUOUSLY. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN
SECTION M1507.3.3. THE SYSTEM SHALL BE DESIGNED TO OPERATE AUTOMATICALLY BASED ON THE TYPE OF
CONTROL TIMER INSTALLED. THE SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. THE
SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER.
AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE ACCORDING TO
THE SCHEDULE USED TO CALCULATE THE WHOLE HOUSE FAN SIZING. A LABEL SHALL BE AFFIXED TO THE
CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)."
M1507.3.2.1 OPERATING INSTRUCTIONS
INSTALLERS SHALL PROVIDE THE MANUFACTURER'S INSTALLATION, OPERATING INSTRUCTIONS, AND A
WHOLE -HOUSE VENTILATION SYSTEM OPERATION DESCRIPTION.
M1507.3.3 MECHANICAL VENTILATION RATE.
THE WHOLE HOUSE MECHANICAL VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR TO EACH HABITABLE SPACE AT A
CONTINUOUS RATE OF NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH TABLE Ml507.3.30).
TABLE M1507.3.30) - MINIMUM VENTILATION RATES (CONTINUOUSLY OPERATING SYSTEMS)
BEDROOMS
SQ FT 0-1 2-3 4-5 6-7 7+
<1500
30
45
60
75
90
1501-3000
45
60
75
90
105
3001-4500
60
75
90
105
120
4501-6000
75
90
105
120
135
6001-7500
90
105
120
135
150
>7501
105
120
135
150
165
M1507.3.3 INTERMITTENTLY OPERATING VENTILATION SYSTEMS.
THE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM IS PERMITTED TO OPERATE INTERMITTENTLY WHERE THE
SYSTEM HAS CONTROLS THAT ENABLE OPERATION FOR NOT LESS THAN 25% OF EACH 4-HOUR SEGMENT AND THE
VENTILATION RATE PRESCRIBED IN TABLE M1507.3.30) IS MULTIPLIED BY THE FACTOR DETERMINED IN ACCORDANCE
WITH TABLE M1507.3.3(2).
TABLE M1507.3.3(2) - VENTILATION RATE FACTORS (INTERMITTENTLY OPERATING SYSTEM)
RUN TIME
(4HR SEGMENT) 25% 33% 50% 66% 75% 100%
FACTOR 4 3 2 1.5 1.3 1.0
VENTILATION CALC
IF RUN CONTINUOUSLY: 60 CFM
IF RUN INTERMITTENTLY: 25%: 240 CFM, 33%: 180 CFM, 50%: 120 CFM, 66%: 90 CFM, 75%: 78 CFM
PREFERRED WHOLE -HOUSE VENTILATION OPTION
M1507.3.4 WHOLE -HOUSE VENTILATION WITH EXHAUST FANS
THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR INTERMITTENT WHOLE HOUSE
VENTILATION SYSTEMS WITH EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION
SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE HOUSE VENTILATION SYSTEM.
CONTINUOUSLY OPERATING EXHAUST FAN WHOLE -HOUSE SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE
FOLLOWING RATES CALCULATED USING TABLES M1507.3.30) AND M1507.3.3(2):
60 CFM (CONTINUOUS)
INTERMITTENTLY OPERATING EXHAUST FAN WHOLE -HOUSE SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE
FOLLOWING RATES CALCULATED USING THE FACTOR TABLE (Ml507.3.3(2)):
EACH UNIT: 240 CFM (25%). 180 CFM (33%). 120 CFM (50%). 90 CFM (66%). 78 CFM (75%)
SEE FLOOR PLANS FOR FAN LOCATIONS. OUTDOOR AIR SHALL BE SUPPLIED TO EACH HABITABLE SPACE. WHERE
OUTDOOR AIR SUPPLY INTAKES ARE SEPARATED FROM EXHAUST VENTS BY DOORS, MEANS SHALL BE PROVIDED
TO ENSURE AIRFLOW TO ALL SEPARATED HABITABLE SPACES BY INSTALLING DISTRIBUTION DUCTS, INSTALLED
GRILLES, TRANSOMS, DOORS UNDERCUT TO A MINIMUM OF 2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR
COVERING, OR OTHER SIMILAR MEASURES WHERE PERMITTED BY THE INTERNATIONAL BUILDING CODE.
M1507.3.4.4 OUTDOOR AIR INLETS.
INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL.
OUTDOOR AIR INLETS SHALL BE LOCATED SO AS TO NOT TAKE AIR FROM THE FOLLOWING AREAS:
1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE
THE OUTDOOR AIR INLET.
2. WHERE IT WILL PICK-UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS.
3. A HAZARDOUS OR UNSANITARY LOCATION.
4. A ROOM OR SPACE HAVING ANY FUEL- BURNING APPLIANCES THEREIN.
5. CLOSER THAT 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT
OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET.
6. ATTIC, CRAWL SPACES OR GARAGES.
M1506.2 EXHAUST OPENINGS.
ALL EXHAUST OPENINGS SHALL COMPLY WITH 2O18 IRC SECTIONS R303.5.2 & R303.6.
1. ALL MECHANICAL WORK TO BE DESIGNED BY SUBCONTRACTOR AND SHALL COMPLY WITH ALL APPLICABLE CODES
AND ORDINANCES.
2. THE MECHANICAL WORK MUST ADHERE TO ALL REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS.
3. VENTILATION OF ALL AREAS SHALL BE IN CONFORMANCE WITH WAC 51-11 AND WAC 51-13, 20181RC, CHAPTER 15,
TABLES M1507.3.3(1) & M1507.3.3(2)
4. ALL EXTERIOR JOINTS AROUND WINDOWS AND DOORS, OPENINGS BETWEEN WALLS AND ROOF OR FOUNDATIONS,
OPENINGS AT PENETRATIONS AND ALL OTHER SUCH OPENINGS SHALL BE SEALED, CAULKED, OR HAVE A GASKET
OR WEATHER STRIPPING TO LIMIT AIR LEAKAGE PER THE 2018 WSEC.
2018 WSEC PRESCRIPTIVE REQUIREMENTS (ZONE 4C, PRESCRIPTIVE OPTION 3):
CREDITS REQUIRED: 6.0 CREDITS FOR MEDIUM DWELLING UNIT.
THE FOLLOWING CREDITS ARE PURSUED:
FUEL NORMALIZATION OPTION 2: DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM (1.0 CREDIT)
OPTION 1.3: EFFICIENT BUILDING ENVELOPE (0.5 CREDIT)
OPTION 2.1: REDUCED AIR LEAKAGE AND EFFICIENT VENTILATION (0.5 CREDIT)
OPTION 3.6: HIGH EFFICIENCY HVAC EQUIPMENT (2.0 CREDITS)
OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER (2.0 CREDITS)
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT PER 2018 WSEC TABLE R402.1.1
AND OPTION 1.3
FLOORS
R-38
CEILINGS (VAULTED)
R-38
CEILINGS
R-49 (R-38 ADV.)
EXTERIOR WALLS (FRAMED 16" O.C.)
R-21
BELOW GRADE WALLS, INT. INSUL.
R-21 + R-5 C.I.
SLAB ON AND BELOW GRADE
R-10 PERIMETER T.B. AND UNDER ENTIRE SLAB
GLAZING - VERTICAL
U-0.28 MAX.
GLAZING - OVERHEAD
U-0.50 MAX.
GLAZING AREA
UNLIMITED
DOORS*
0.30 MAX w/ 1 EXEMPT
DUCT INSULATION
R-8
HOT WATER PIPE
R-4
WINDOW AND DOOR HEADERS
R-10
*EXTERIOR DOORS ARE TO BE 1- 4" SOLID CORE WITH FULL WEATHER STRIP AND TRESHOLD. ALL GLAZING IN
EXTERIOR DOORS IS TO BE DOUBLE GLAZED WITH SAFETY GLASS.
5. CREDIT OPTION 2.1: REDUCE THE TESTED AIR LEAKAGE TO 3 AIR CHANGES PER HOUR MAX. VENTILATION TO BE
PROVIDED BY HIGH EFFICIENCY FANS (0.35W / CFM). VENTILATION FANS SHALL BE "WHISPERWARM DC" AS MFR'D
BY PANASONIC (0.11 W / CFM) OR APPROVED EQUAL.
6. CREDIT OPTION 3.6: DUCTLESS SPLIT SYSTEM HEAT PUMPS WITH NO ELECTRIC RESISTANCE HEATING. SPLIT HEAT
PUMP SYSTEMS SHALL BE DESIGN -BUILD AND HAVE A MIN. HSPF OF 10.
7. AN ALTERNATIVE HEATING SOURCE SIZED AT 0.5 WATTS / SF OR 500W, WHICHEVER IS LARGER, MAY BE INSTALLED
PURSUANT TO WSEC TABLE 406.3 FOOTNOTE 2.
8. CREDIT OPTION 5.5: WATER HEATING SYSTEM SHALL BE A HEAT PUMP WATER HEATER COMPLYING WITH TIER 3 OF
NEEA'S ADVANCED WATER HEATING SPECIFICATION. WATER HEATER SHALL BE PRESTIGE PROPH50-T2-RH350-DCB
AS MFR'D BY RHEEM OR APPROVED EQUAL.
9. SLAB ON GRADE FLOORS SHALL HAVE R-10 RIGID INSULATION UNDER THE ENTIRE SLAB WITH AN R-5 TAPERED
THERMAL BREAK AT ALL SLAB EDGES.
10. GLAZING AREA ALLOWED IS UNLIMITED, GROUP R-3 ONLY. ALL EXTERIOR GLAZING SHALL BE DOUBLE GLAZED
(MIN.).
11. ALL FURTHER CALCULATIONS ARE TO BE PROVIDED BY THE MECHANICAL CONTRACTOR PRIOR TO APPLYING FOR A
MECHANICAL PERMIT.
12. HEATING DESIGN TEMPERATURES: (PER WA STATE ENERGY CODE) HEATING: 70 DEGREES INSIDE AND 46 DEGREES
OUTSIDE.
13. PROVIDE DUCT INSULATION AS REQUIRED BY WSEC R403.2.1.
14. SOURCE SPECIFIC VENTILATION. VENTILATION (EXHAUST) SHALL BE PROVIDED IN BATHROOMS, KITCHENS,
LAUNDRY ROOMS, POOL ROOMS AS WELL AS IN OTHER ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR
ARE PRODUCED, AS REQUIRED BY THE 2018 IRC, CH.15. PER TABLE M1507.4.
15. A WHOLE HOUSE VENTILATION SYSTEM SHALL BE INSTALLED OF EITHER INTERMITTENT OR CONTINUOUS
OPERATION AS REQUIRED BY THE 2018 IRC, CH.15.
16. DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN
APPROVED FINAL INSPECTION PER WSEC 101.4.3.1 & 403.2 A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE
TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION.
17. A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH WSEC 401.3 IS REQUIRED TO BE COMPLETED
BY THE DESIGN PROFESSIONAL OR BUILDER AND PERMANENTLY POSTED WITHIN 3' OF THE ELECTRICAL PANEL
PRIOR TO FINAL INSPECTION.
18. INSULATION INSTALLERS SHALL PROVIDE A CERTIFICATION LISTING THE TYPE, MANUFACTURER AND R-VALUE OF
INSULATION INSTALLED IN EACH ELEMENT OF THE BUILDING THERMAL ENVELOPE (WSEC R303.1.1)
19. THE BUILDING OFFICIAL, UPON NOTIFICATION, SHALL MAKE A WALL INSULATION INSPECTION IN ADDITION TO
THOSE INSPECTIONS REQUIRED IN SECTION R109 OF THE IRC. THIS INSPECTION SHALL BE MADE AFTER ALL WALL
AND CAVITY INSULATION IS IN PLACE AND PRIOR TO COVER (WSEC R104.2.1)
20. A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT AND EAVE VENTS FOR AIR PERMEABLE INSULATIONS IN
VENTED ATTICS. (WSEC R402.2.3)
21. ACCESS HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED AND
INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES (WSEC R402.2.4)
22. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT
EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL COMPLY WITH SECTION R402.4.1.2 OF THE 2018 WSEC. TEST
RESULTS SHALL BE POSTED ON THE RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE (SEC 105.4)
23. EACH DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR THE
REGULATION OF TEMPERATURE PER 2018 WSEC 403.1.
24. MINIMUM 75% OF ALL INTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES.
25. ALL EXTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES.
26. PER 2018 WSEC R402.2.7 FLOOR INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE
UNDERSIDE OF THE SUB -FLOOR DECKING. INSULATION SUPPORTS SHALL BE INSTALLED SO SPACING IS NO MORE
THAN 24" ON CENTER. FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS BELOW THE
LOWER SURFACE OF THE FLOOR INSULATION.
27. U-FACTORS OF FENESTRATION PRODUCTS (WINDOWS, DOORS AND SKYLIGHTS) SHALL BE DETERMINED IN
ACCORDANCE WITH NFRC 100. PRODUCTS SHALL BE LABELED AND CERTIFIED BY THE MFR.
PLUMBING NOTES
1. ALL PLUMBING WORK IS TO BE DESIGNED BY SUBCONTRACTOR AND SHALL COMPLY WITH ALL APPLICABLE CODES
AND ORDINANCES.
2. PLUMBING CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS RELATED TO THE PARTY'S SCOPE
OF WORK.
3. PROVIDE PRESSURE RELIEF VALVE FOR HOT WATER TANK. DRAIN TO THE OUTSIDE OF THE BUILDING WITH DRAIN
END NOT MORE THAN TWO FEET NOR LESS THAN 6" ABOVE THE GROUND, POINTING DOWN.
4. HOT WATER TANKS HAVING FLEXIBLE PIPE CONNECTIONS AND OVER 4 FT TALL SHALL BE STRAPPED DOWN TO
PREVENT OVERTURN IN THE EVENT OF AN EARTHQUAKE.
5. HOT WATER HEATERS LOCATED IN GARAGES SHALL BE ELEVATED PER 2018 IRC P2801.6.
6. PROVIDE AN APPROVED BACK FLOW PREVENTION DEVICE AT ALL HOSE BIBS.
7. CONTRACTOR SHALL PROVIDE A DWV AND HOT WATER DISTRIBUTION RISER DIAGRAM FOR COUNTY AND
ARCHITECT REVIEW.
8. EACH HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL.
9. CONTRACTOR TO PROVIDE HORIZONTAL DRAINAGE PIPING THAT MEETS UPC FOR SLOPE REQUIREMENTS.
DRYWALL NOTES
1. PROVIDE%" GYPSUM WALL BOARD FOR NON -RATED ASSEMBLIES AND 4" TYPE X GWB FOR 1-HOUR RATED
ASSEMBLIES WITH ALL EXPOSED JOINTS AND FASTENER HEADS SMOOTH AND FLUSH WITH SURFACE OF
BOARDS, JOINTS TAPED AND PREPARED FOR APPLICATION OF FINISH, USE WATER-RESISTANT BOARD AT ALL
WET AREAS TO 4' AFF.
2. "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD LATEST EDITION,
AS PUBLISHED BY THE GYPSUM ASSOCIATION (ALSO PUBLISHED AS ANSI 97. 1 AND " USING GYPSUM BOARD AND
CEILING", LATEST EDITION).
3. WHEN GYPSUM BOARD IS USED AS A BASE FOR TILE OR WALL PANELS FOR TUB, SHOWER OR WATER CLOSET
COMPARTMENT WALLS, WATER RESISTANT GYPSUM BACKING BOARD SHALL BE USED PER IRC SECTION R702.4.2
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v
`W
v
O
=O
N
Z00
Z 0�
O�
O
Z
O
O
LU "'
J
w
aw
F-
LU
Oa
0
CD
CM M
City of EDMONDS
Permit Set
October 7, 2022
Revision 1
10/21 /22
Revision 2
04/03/23
Revision 3
09/15/23
Revision 4
02/05/24
Revision 5
06/10/24
b
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ARCHITECTURAL
GENERAL NOTES
SCALE: AS NOTED
AOO
UNIT
Window, Skylight and Door Schedule
Project Information
310 DALEY TOWNHOMES - UNIT A
310 DALEY STREET
EDMONDS, WA 98020
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description Ref. U-factor
1: AND-N-84-00899-00001
MFR.
0.27
2: AND-N-82-03683-00001
MFR.
0.28
10: AND-N-82-03683-00001
MFR.
0.28
11: AND-N-84-00899-00001
MFR.
0.27
12: AND-N-82-03683-00001
MFR.
0.28
11 AND-N-82-03683-00001
MFR.
0.28
26: AND-N-82-03683-00003
MFR.
0.28
2T AND-N-82-03683-00003
MFR.
0.28
28: AND-N-82-03683-00003
MFR.
0.28
29: AND-N-82-03683-00001
MFR.
0.28
44: AND-N-82-03683-00001
MFR.
0.28
45: AND-N-84-00899-00001
MFR.
0.27
46: AND-N-82-03683-00001
MFR.
0.28
4T AND-N-82-03683-00001
MFR.
0.28
48: AND-N-82-03683-00001
MFR.
0.28
49: AND-N-82-03683-00001
MFR.
0.28
50: AND-N-82-03683-00001
MFR.
0.28
51: AND-N-82-03683-00001
MFR.
0.28
52: AND-N-82-03683-00001
MFR.
0.28
51 AND-N-82-03683-00001
MFR.
0.28
A: Jeld-Wen Full-Lite w/ Low-E Glazing
MFR.
0.29
J: AND-N-100-01122-00001
MFR.
0.29
K: AND-N-100-01122-00001
1MFR.
0.29
Contact Information
CITIZEN DESIGN
10 DRAVUS SEATTLE, WA, 98109
206.535.7908
Width Height
Qt. Feet Inch Feet Inch
Width Height
Qt. Feet Inch Feet Inch
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
simple Heating system Size: Washington State
Area UA
11
111
11
111
Area UA
10.0
2.70
20.0
5.60
15.0
4.20
8.0
2.16
16.0
4.48
10.0
2.80
26.0
7.28
26.0
7.28
38.5
10.78
10.0
2.80
27.5
7.70
11.0
2.97
7.5
2.10
7.5
2.10
7.5
2.10
7.5
2.10
5.01
1.40
5.0
1.40
5.0
1.40
7.5
2.10
0.0
0.00
0.0
0.00
21.0
6.09
42.0
12.18
42.0
12.18
375.5 105.90
0.28
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Project Information
Contact Information
310 DALEY TOWNHOMES - UNIT A
CITIZEN DESIGN
310 DALEY STREET
10 DRAVUS, SEATTLE, WA 98109
EDMONDS, WA 98020
206.535.7908
Heating System Type: O All other Systems
O Heat Pump
To see detailed instructions for each section, place your cursor on the word "Instructions"
Design Temperature
Instructions
Edmonds
Design Temperature Difference (AT) 46
I
AT = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
1,774
Average Ceiling Height
Conditioned Volume
Instructions Average Ceiling Height (ft)
8.3 14,723
Glazing and Doors
U-Factor X Area = UA
Instructions
tou-0.28 ,
0.280 376 105.28
Skylights
Instructions
Insulation
U-Factor X Area = UA
0.50 01 ---
Attic
U-Factor
X
Area =
UA
Instructions
�Select R-Value �
No selection
0
---
Single Rafter or Joist Vaulted Ceilings J
U-Factor
X
Area
UA
Instructions R-38 Vented V
0.027
719
19.41
eeFlgurel) J
Above Grade WalJR-21
U-Factor
X
Area
UA
Instructions
Intermediate V
0.056
1, 956
109.54
Floors
U-Factor
X
Area
UA
_
Instructions R-38
0.025
1,446
36.15
Below Grade Walls (see Figure 1)
U-Factor
X
Area
UA
instructions
No Below Grade Walls in V
0.028
0�
this project.
L
Slab Below Grade (see Figure 1)
F-Factor
X
Length
UA
Instructions
0.303
0�
---
No Slab Below Grade in this project. V
Slab on Grade (see F urel
F-Factor
X
Length
UA
Instructions
0.360
73
26.40
R-10 R insulin -
Location of Ducts
Instructions 1
Duct Leakage Coefficient
NO Ducills V
1.00
Sum
of UA
296.77
Envelope Heat Load
13 652 Btu / Hour
Figure 1.
Above Grade
Sum of UA x AT
Air Leakage Heat Load 7,314 Btu / Hour
Volume x 0.6 x AT x 0.018
Building Design Heat Load 20,966 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 20,966 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 26,207 Btu / Hour
Buildinq and duct heat loss x 1.40 for forced air furnace
Buildinq and duct heat loss x 1.25 for heat pump
UNIT B
M
Window, Skylight and Door Schedule
Project Information Contact Information
310 DALEY TOWNHOMES - UNIT B CITIZEN DESIGN
310 DALEY STREET 10 DRAVUS SEATTLE, WA, 98109 M
EDMONDS, WA 98020 206.535.7908
M
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description Ref. U-factor
3: AND-N-82-03683-00001
MFR.
0.28
4: AND-N-84-00899-00001
MFR.
0.27
14: AND-N-82-03683-00001
MFR.
0.28
15: AND-N-82-03683-00001
MFR.
0.28
16: ND-N-84-00899-00001
MFR.
0.27
25: AND-N-82-03683-00003
MFR.
0.28
42: AND-N-82-03683-00001
MFR.
0.28
41 AND-N-84-00899-00001
MFR.
0.27
B: Jeld-Wen Full-Lite w/ Low-E Glazing
MFR.
0.29
L: AND-N-100-01122-00001
1MFR.
10.29
Width Height
Qt. Feet Inch Feet Inch
Width Height
Qt. Feet Inch Feet Inch
EMEEE
EEEME
EEEEE
EMEME
EEEEE
EEEME
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
EEEEE
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Area UA
11
111
11
111
I_�. �gy 1
16.0
4.48
8.0
2.16
12.0
3.36
16.0
4.48
8.01
2.16
15.8
4.41
27.5
7.70
11.0
2.97
0.0
0.00
0.0
0.00
0.0
0.00
21.0
6.09
42.0
12.18
177.3 49.99
0.28
Simple Heating System Size: wasnington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Project Information Contact Information
310 DALEY TOWNHOMES - UNIT B CITIZEN DESIGN
310 DALEY STREET 10 DRAVUS, SEATTLE, WA 98109
EDMONDS, WA 98020 206.535.7908
Heating System Type: o all other systems O Heat Pump
To see detailed instructions for each section, place your cursor on the word "Instructions"
Design Temperature
Instructions Design Temperature Difference (AT) 46
mond' AT = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
1,407
Average Ceiling Height
Conditioned Volume
Instructions Average Ceiling Height (ft)
8.3
11,717
Glazing and Doors
U-Factor
X
Area =
UA
Instructions 1
u-0z8 IV J
0.280
177
49.56
Skylights
U-Factor
X
Area =
UA
Instructions
0.50
---
Insulation
Attic
U-Factor
X
Area =
UA
Instructions Select R-Value .
No selection
0
---
Single Rafter or Joist Vaulted Ceilings
U-Factor
X
Area
UA
Instructions R-38Vented
0.027
570
15.39
Above Grade Walls (see Figure 1)
U-Factor
X
Area
UA
Instructions
R-21 Intermediate �
0.056
770
43.12
�
J
Floors
U-Factor
X
Area
UA
Instructions
�
0.025
1,140
28.50
R-38
Below Grade Walls (see Figure 1)
U-Factor
X
Area
UA
Instructions L
0.028
No Below Grade Walls in this project. J
Slab Below Grade (see Figure 1)
F-Factor
X
Length
UA
Instructions
0.303
0�
---
No Slab Below Grade in this project
Slab on Grade (see F ure1)
F-Factor
X
Length
UA
Instructions
�
0.360
66
23.58
R-10 Fully Insulated
Location of Ducts
Instructions 1
Duct Leakage Coefficient
No Ducts 1
1.00
Sum
of UA
160.15
Envelope Heat Load
7 367 Btu / Hour
Figure 1.
Above Grade
Sum of UA x AT
Air Leakage Heat Load 5,821 Btu / Hour
Volume x 0.6 x AT x 0.018
Building Design Heat Load 13,188 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 13,188 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 16,485 Btu / Hour
Buildinq and duct heat loss x 1.40 for forced air furnace
Buildinq and duct heat loss x 1.25 for heat pump
CITIZEN
DESIGN
RESUB
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v
`W
v
0
o
N
Zao
o�
0
O
Z
O
O
W "'
J w
Q w
H
w
O Q
CD
CM M
City of EDMONDS
Permit Set
October 7, 2022
ZN
Revision 1
10/21/22
ZL
Revision 2
04/03/23
Revision 3
09/15/23
Revision 4
02/05/24
Revision 5
06/10/24
A6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ENERGY CODE
ANALYSIS:
M UNITS AAND B
SCALE: AS NOTED
A002
UNIT
Window, Skylight and Door Schedule
Project Information
310 DALEY TOWNHOMES - UNIT C
310 DALEY STREET
EDMONDS, WA 98020
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description Ref. U-factor
5: ND-N-84-00899-00001
MFR.
0.27
6: AND-N-82-03683-00001
MFR.
0.28
17: ND-N-84-00899-00001
MFR.
0.27
18: AND-N-82-03683-00001
MFR.
0.28
19: AND-N-82-03683-00001
MFR.
0.28
24: AND-N-82-03683-00001
MFR.
0.28
40: AND-N-84-00899-00001
MFR.
0.27
41: AND-N-82-03683-00001
MFR.
0.28
C: Jeld-Wen Full-Lite w/ Low-E Glazing
MFR.
0.29
L: AND-N-100-01122-00001
1MFR.
0.29
Contact Information
CITIZEN DESIGN
10 DRAVUS SEATTLE, WA, 98109
206.535.7908
Width Height
Qt. Feet Inch Feet Inch
Width Height
Qt. Feet Inch Feet Inch
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Area UA
11
111
11
111
Area UA
8.0
2.16
16.0
4.48
8.0
2.16
16.0
4.48
12.01
3.36
15.8
4.41
11.0
2.97
27.5
7.70
0.0
0.00
0.0
0.00
0.0
0.00
21.01
6.09
42.01
12.18
177.3 49.99
0.28
Simple Heating System size: Washington state
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Project Information Contact Information
310 DALEY TOWNHOMES - UNIT C CITIZEN DESIGN
310 DALEY STREET 10 DRAVUS, SEATTLE, WA 98109
EDMONDS, WA 98020 206.535.7908
Heating System Type: O All Other Systems Heat Pump
To see detailed instructions for each section, place your cursor on the word 'Instructions"
Design Temperature
Instructions Design Temperature Difference (AT) 46
Edmonds V AT = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
1,407
Average Ceiling Height
Conditioned Volume
Instructions Average Ceiling Height (ft)
8.3
11,717
Glazing and Doors
U-Factor
X Area =
UA
Instructions
ILU-0.28
-
0.280
177
49.56
Skylights
U-Factor
X Area =
UA
Instructions
0.50
--
Insulation
Attic
U-Factor
X Area =
UA
Instructions L Select R-Value
.
No selection
0�
---
Single Rafter or Joist Vaulted Ceilings
U-Factor
X Area
UA
Inst uctio'7s I R-38Vented
0.027
570
15.39
Above Grade Walls (see Figure t)
J U-Factor
X Area
UA
Instructions IL R-21Intermediate
0.056
770
43.12
Floors
U-Factor
X Area
UA
Instructions
0.025
1,140
28.50
R-38
Below Grade Walls (see Figure 1)
U-Factor
X Area
UA
Instructions
0.028
0�
No Below Grade Walls in this project.
®
--------
Slab Below Grade (see Figure 1)
F-Factor
X Length
UA
Instructions
I
I
0.303
0�
---
No Slab Below Grade in this project.
I�
Slab on Grade (see Figure 1)
F-Factor
X Length
UA
Instructions
�
0.360
66
23.58R-10
Fully Insulated
�
Location of Ducts
Instructions y
Duct Leakage Coefficient
No Ducts
1.00
Sum of UA
160.15
Envelope Heat Load
7 367 Btu / Hour
Figure 1.
Above Grade
Sum of UA x AT
Air Leakage Heat Load 5,821 Btu / Hour
Volume x 0.6 x AT x 0.018
Building Design Heat Load 13,188 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 13,188 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 16,485 Btu / Hour
Buildinq and duct heat loss x 1.40 for forced air furnace
Buildinq and duct heat loss x 1.25 for heat pump
UNIT D
M
Window, Skylight and Door Schedule
Project Information Contact Information
310 DALEY TOWNHOMES - UNIT D CITIZEN DESIGN
310 DALEY STREET 10 DRAVUS SEATTLE, WA, 98109 M
EDMONDS, WA 98020 206.535.7908
M
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description Ref. U-factor
7: AND-N-82-03683-00001
MFR.
0.28
8: AND-N-84-00899-00001
MFR.
0.27
9: AND-N-82-03683-00001
MFR.
0.28
20: AND-N-82-03683-00001
MFR.
0.28
21: AND-N-82-03683-00003
MFR.
0.28
22: AND-N-82-03683-00003
MFR.
0.28
23: AND-N-82-03683-00003
MFR.
0.28
30: AND-N-84-00899-00001
MFR.
0.27
31: AND-N-82-03683-00001
MFR.
0.28
32: AND-N-82-03683-00001
MFR.
0.28
33: AND-N-82-03683-00001
MFR.
0.28
34: AND-N-82-03683-00001
MFR.
0.28
35: AND-N-82-03683-00001
MFR.
0.28
36: AND-N-82-03683-00001
MFR.
0.28
37: AND-N-82-03683-00001
MFR.
0.28
38: AND-N-84-00899-00001
MFR.
0.27
39: AND-N-82-03683-00001
MFR.
0.28
D: Jeld-Wen Full-Lite w/ Low-E Glazing
MFR.
0.29
I: AND-N-100-01122-00001
MFR.
0.29
N: AND-N-100-01122-00001
MFR.
0.29
Width Height
Qt. Feet Inch Feet Inch
1
Width Height
Qt. Feet Inch Feet Inch
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Area UA
11
111
11
111
Area UA
20.0
5.60
10.0
2.70
15.0
4.20
10.0
2.80
38.51
10.78
26.0
7.28
26.0
7.28
10.0
2.70
5.0
1.40
5.0
1.40
5.0
1.40
7.5
2.10
7.5
2.10
7.5
2.10
7.5
2.10
11.0
2.97
27.5
7.70
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
21.0
6.09
42.01
12.18
42.01
12.18
344.0 97.06
0.28
Simple Heating System Size: Washington state
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Project Information Contact Information
310 DALEY TOWNHOMES - UNIT D CITIZEN DESIGN
310 DALEY STREET 10 DRAVUS, SEATTLE, WA 98109
EDMONDS, WA 98020 206.535.7908
Heating System Type: O All Other Systems Heat Pump
To see detailed instructions for each section, place your cursor on the word 'Instructions"
Design Temperature
Instructions Design Temperature Difference (AT) 46
Edmonds i AT = Indoor (70 degrees) - Outdoor Design Temp
_ J
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
1,774
Average Ceiling Height
Conditioned Volume
instructions Average Ceiling Height (ft)
8.3
14,723
Glazing and Doors
U-Factor
X Area =
UA
Instructions
u-o.zs .
0.280
344
96.32
I
Skylights
U-Factor
X Area =
UA
Instructions
0.50
0�
---
Insulation
Attic
U-Factor
X Area =
UA
Instructions Select R-Value
No selection
0
---
Single Rafter or Joist Vaulted Ceilings
U-Factor
X Area
UA
Instructions 6[R-38 Vented
0.027
719
19.41
Above Grade Walls (See Figure 1)
U-Factor
X Area
UA
Instructions R-21Intermediate V 1
0.056
1,996
111.78
J
Floors
U-Factor
X Area
UA
Instructions
0.025
1,438
35.94
R-38 V
Below Grade Walls (see Figure 1)
U-Factor
X Area
UA
Instructions No in V
0.028
Below Grade Walls this project.
Slab Below Grade (see Figure 1)
F-Factor
X Length
UA
Instructions I
�
0.303
0�
---
1 No Slab Below Grade in this project.
Slab on Grade (see Figure 1)
F-Factor
X Length
UA
Instructions
�
0.360
73
26.40
6R-10 Fully Insulated
Location of Ducts
Instructions I
No Ducts J
Duct Leakage Coefficient
1.00
Sum
of UA
289.84
Envelope
Heat Load
13 333 Btu / Hour
Figure 1.
Sum of UA x AT
Air Leakage Heat Load 7,314 Btu / Hour
Volume x 0.6 x AT x 0.018
Building Design Heat Load 20,647 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 20,647 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 25,809 Btu / Hour
Buildinq and duct heat loss x 1.40 for forced air furnace
Buildinq and duct heat loss x 1.25 for heat pump
CITIZEN
DESIGN
RESUB
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v
`W
v
0
o
N
Zao
o�
0
0
Z
O
0
W "'
J w
Q W
H
W
CDQ
0
tI CD
CM M
City of EDMONDS
Permit Set
October 7, 2022
ZN
Revision 1
10/21/22
ZL
Revision 2
04/03/23
Revision 3
09/15/23
Revision 4
02/05/24
Revision 5
06/10/24
A6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ENERGY CODE
ANALYSIS:
M UNITS CAND D
SCALE: AS NOTED
A003
2018 Washmgton Stare Energy Code- Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Stngle Family - New &Additions (effective February 1, 2021) vttevcr
These requirements apply to all 1RC building types, including detached one- and two-famity
dwellings and multiple single-family dwellings (townhouses).
ct taftwmatka Contod kiforme0on
10 DW eV Townho-re5 (TYRALLUNITS) Jacob your
310 Daley St Edmaricls WA 96020 ivouno@co4aborawom.com
Instructions: This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values Iisted. based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant -
Provide all information from the blowing tables as budding permit drawiings: Table R402.1- Insulation and
Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 4106.3 - Energy Credits.
Aurhorited Represen-4ative I Deft
i
All Cli nat4 Zoom 11rable R402.1.1
ii-value •
N-FtlOW °
Fenestration U-;actor
nla
0,30
Skylight U-Facto► b
n/a
0-30
Glazed hvnestratlon SHGC °''
n/a
n/a
Calling'
49
0,026
Wood Frame Wag az
21 Int
0.056
Floor
30
0-029
Below Grade Wall `^
10/15/21 int • TO
0,042
Slab' R-Value & Dep th
10, 2 It
n/a
R-values are muu moms. U-factors and SW are mavenums When insulation is installed m a cavity that It less
a
than the label or design thickness of the insulaton, the compressed R-value of the Insulation Itom Appendix
Table A10L4 shall not be less than the R-value s cAied in the table_
b
TM fenestrat-on U-factor column excludes sit . hts-
"10/15/21 -STB' means R-10 conti-woos iniulation on the exterior of the wall, or R-15 continuous Insulation on
the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c
the interior of the baserneni wall. "10/1S/21 STB' shall be permitted to be met Frith R-13 cavrty insulation on
the interior of the basement war plus R-5 continuous insulation on the LWonor or extrrtor of the wal'. "STR'
meam R-S thermal break tietween floor slab and basement wall,
Q
R-10 continuous insulation is required under heater slab on giade floors See Section R402.2.9.1.
For wig4 rafter• or foiv.vaufted ceilings, the insulation may be reduced to Il-38 if the full insulation depth
e
extends over the top plate of the exteow wall
R-7.5 continuous insulation iistaliled over an existing &Wb is deemed to be equivalent to the required perimeter
f
slab insulation when applied to edsting stabs complying with Section RS01I.1. If foam plastic is used, it shall
meat the requirements for thermal barriers protecting foam plastics -
for 109 structures developed in compliance with Standard ICC 400, ictg walls shah meet the regtlireneents for
g
c-Nmtrte zone S of ICC 400.
lnt, (intermediate framinBI denotes fram=ng and insulation as described in Section A103,2.1 irtckKtttg s:anciard
h
framing 16 Inches on center. 78% of the will cavity insulated and headers insulated with a minimum of R-10
H%Oarron.
Preecrove Pool - sinyib Fetmov 2318'r wri, vVi SIPMa Erwgv Coder-R
20I8 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for AN Clinswe Zones In Washington
Single Ftitrtdty-New a Add1Vons,t %*'Februaty 1. 2WA
Each dwelling unit in o residential building shall comply with sufficient options from Table R406.2 (fuel
nofmatiratlon credits) and Table 406.3 (energy credits) to Achieve the following minimum number of
credits, To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested budding air leakage, and show the qualifying ventilation system and its controi sequence
of operation.
1- Small Dwelling Unit: 3 credits
Dwelling units less than L500 sf In conditioned floor area with less than 300 sf of fenestration area
Additions to existing building that are greater than 500 sf of heated floor area but Ifte. than 1,500 sf.
2. Medium Dwelling Unit: 6 credits
All dwelling units that are not included in M1 or 43
3 Larga Dwrlfing Unit; 7 orgies
Dwelling units exceeding 5,000 sf of conditioned floor area
4_ Additions less than 500 square feet: 1.5 vritl!s
All other additions %hall rr►ert 1-3 above
More seleel tg your credits on this Summary table, review the details In Table ,106.3 (Single Family(, on oMe 4
Summary of Table R406.2
Nest"
dm
Fuel Norn►arbation Descriptions
Credits - select ONE
heating op"on
User Notes
i
Combustion heating minimum NIAECA"
0.0
O
2
Heat punW
1.0
O
3
Electric resistance heat only - furnace or zonal
-1.0
O
4
DHP with zonal electric resistance per option 34
0.5
O
5
All other heating systems
-1.0
1 O
Esfww
Energy Credit Opt6oin Dewiptions
Credits - soMct ONE
energy option from each
catetory'
11
Efficlem 8utiding Enveiaoe
0,5
O
1.2
Effiicic%t 6urklmg Envriopc
1.0
O
1.1
Effitier►t buildrry. t Envelope
0.5
(D
1.4
Efficient Buikfing Envelope
1.0
O
1.S
Fffiicient Rurit ling Fnvi:lopc
1.0
O
1.6
Efficient Building Envelope
1.0
O
1.7
Efficient Building Envelope
OS
O
2.1
Air leakage Control and Efficient Ventilation
0.5
O
1.2
Air Leakap Control and Efficient Ventilation
1.0
O
2.3
AN I.Amikage Control dnd Efficient Ventilation
is
O
2.4
Air Leaks o Control and Efficient Ventilation
2,0
O
3.111
High Efflcieticy HVAC
1.0
O
2
High E>fid HVAC
1,0
O
3.10
Hlgh Efficiency HVAC
15
O
3.4
High Efficiency HVAC
I.S
O
3.5
High Efficiency HVAC
1.5
O
3.6'
High Elflclency HVAC
1.0
O
4.1
High Efficiency HVAC Dotnbution Systern
0.5
O
4.2
High Efficiency HVAC Distribution System
1,0
O
Pt6WX fiwPtdh-6ingiaFamiiy 2.31fl1'1'uere,VXr StW*ErW9yC0de-q
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for Afl Climate Zones in Washington
Single Family - Kew r6 Additions (aHective February 1, 2021)
Summary of Table R406.2 (coot.)
Energy
Optims
Energy Cmdit Option Descripbons (cunt-)
Credits - select ONE
energy option from
eacah eatemory'
Vsrr Notes
51r
Efrdent Water l4ealing
❑
O
O
O
0
O
5.2
Efficient Water Heating
D.5
51
Efficient Water Heating
1-0
5.4
Ffficient Water Heats
1.S
5.5
Effident Water Heats
2-0
5.5
Efficient Water Hearing 0
2.5
61'
Renowable Elw.ric Energy f.3 crrd,ti max)
1 A
7.1
Appliance Pack
0.5
rotat OedMts
E.0
1011illwouW I caw Form
a An alternative heating sauna sired at a maximum of 0 5 W/sf lequivaiont) of heateo fiocu area or SOD W.
whichever is bigger, may be installed in the dwelling unit
b. £qutpment listed in Table C403.3.214) or C403.3.215)
c. Equipment fisted in Table C403.3.211) or C403.3.212)
d, You cttmtot select more than one option from any category EXCEPT in category S. Option S.,1 may be combined
with options S-2 "wough S.6. See Table 406.3.
e. 1,0 credit for each 1.200 kWh of electrical generation provided annually, up to 3 credo. male
See the complete Table R406.2 for all requirements acid option descriptions
+ Use the sine rod o bwon n the upper -q t of t-ie second cokurtn ro deselect radiobuttot-s n that group
Please prIM cwd popm 1 through 3 of this worksheel for futftsiion to ywr- twilding official.
P'eucrV.1" Poo, - sillyle Fatnoo 2318'iVa9-itgiyt °,ip a Eriogy Code-R
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z o
00
o%
O
Z
Z
0
L U L1
J w
Q W
H
w
Q
C3
0
CM M
City of EDMONDS
Permit Set
October 7, 2022
ZN
Revision 1
10/21/22
ZL
Revision 2
04/03/23
Revision 3
09/15/23
Revision 4
02/05/24
Revision 5
06/10/24
�6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ENERGYCODE
' COMPLIANCE:
M ALL UNITS
L SCALE: AS NOTED
A004
TREE TABLES
EXISTING TREES
MARK
TRUNK 0
DRIP LINE 0
SPECIES
CONDITION
REMOVED?
NOTES
1
11"
10 FT
REDWOOD
FAIR
YES
POOR FORM, FORKED LOWER TRUNK
2
14"
20 FT
FLOWERING CHERRY
GOOD
YES
COMPROMISED BY CONSTRUCTION
3
7"
10 FT
NORWAY MAPLE
GOOD
NO
ON BOUNDARY LINE
PROPOSED TREES
MARK
TRUNK 0
SPECIES
A
1%"
PYRAMIDAL EUROPEAN HORNBEAM (CARPINUS BETULUS 'FASTIGIATA')
B
1%"
PYRAMIDAL EUROPEAN HORNBEAM (CARPINUS BETULUS 'FASTIGIATA')
C
1%"
PYRAMIDAL EUROPEAN HORNBEAM (CARPINUS BETULUS 'FASTIGIATA')
D
1%"
PYRAMIDAL EUROPEAN HORNBEAM (CARPINUS BETULUS 'FASTIGIATA')
E
1%"
PYRAMIDAL EUROPEAN HORNBEAM (CARPINUS BETULUS 'FASTIGIATA')
AVERAGE GRADE CALCULATION
(53.39') + (54.09') + (54.10 + (53.75')
4
215.39 = 53.85'
4
/
/ ya
408 3RD AVENUE N
APN:004342-119-038-00 / /4
ZONED: RS-6 �� 4",
A
/
Z
LU
w q
Q
S
0 ° 12 e CATCH BASIN
o4
z �/ •RIM=51.25'
M / O� j IE=48.45' (BTM)
IE=49.55' (8" W)
STORM MANHOLE
RIM=51.77' +
IE=46.62' (N-S)
q � / IE=48.97' (E)
TYP.
/ CATCH BASIN
3 RIM=51.58'
o� IE=49.38' (BTM) C
/ IE=49.78' (8" WP.
W w-WW
SANITARY MANHOLE
RIM=52.04'
IE=45.34' Vry�
CENTERLINE MONUMENT e a
FOUND EXISTING p '�
MONUMENT IN CASE ON
a a
a
JULY 27, 2021 ° D . V
N=300,639.0910 p
E=1,260,998.0680 o
a
3 a
a p
N W °
n j✓/
�A a
Doti h. , i
U
00
I I
00
a
a
4� cV
I
30'-0" HALF ROW
ZONING SITE PLAN
SCALE: 1 " = 10'
/ CO
OKI
Zone BD-2
Corner Flag _
Setbacks:
Required Actual
Front
of
------------------------
-------------
Sides
0f
------------' '--------
Rear
o'
Other
30' 29'
Height
FG = 54.95'±
20 \
� I
305 4TH AVENUE N
AP N : 004342-026-005-00
23 ZONED: BDI5
14
FG = 54.50'±
24'-0" BACKING DISTANCE -
303 4TH AVENUE N
APN:004342-026-009-01
ZONED: BD-5
CATCH BASIN
RIM=53.94'
IE UNAVAILABLE
(FILLED IN)
_4 ^ 24 TYP.
+ tilb A\'
n +� /
CATCH BASIN
RIM=53.71'
3 jIE=51.71' (BTM)
IE=51.81' 00" SW)
IE=51.21' (6" NE)
ti ti
P _�_ �K 4?
P _ _
TYP. P''
24 16-0" ALLEY' Z o
\ Z) a �n
O� I w CD
o m
N
26 =adz
M o
M o
(4, V 4,A �$L,
TRUE PROJECT
I r
0 5 10 20 Q
1 =10 ZL
ZL
KEYNOTES
1. (N) STREET FRONTAGE IMPROVEMENTS PER CIVIL.
(SHOWN FOR REF. ONLY)
2. (E) TREE TO REMAIN.
3. SURVEYED LOCATION OF (E) UTILITIES. SHOWN FOR REF. ONLY.
4. DEMOLISH (E) DUPLEX AND GARAGE UNDER SEPARATE PERMIT.
5. REMOVE (E) UTILITY POLE, GUY, AND OVERHEAD STRIKES.
6. (N) UTILITY POLE PER CIVIL. SHOWN FOR REF. ONLY.
7. (N) UNDERGROUND POWER SERVICE FOR NEIGHBORING LOT PER
CIVIL. SHOWN FOR REF. ONLY.
8. 2 FT MAX HT CONCRETE WALL PER STRUCTURAL.
9. 4 FT WIDE CONCRETE WALK PER CIVIL.
10. 4 FT WIDE SITE STAIRS (3R @ 6", 2T @12").
11. 8.5 FT x 16.5 FT PARKING SPACE.
12. (N) TREE PER LANDSCAPE. SHOWN FOR REF. ONLY.
13. LINE OF CANOPY (ABOVE).
14. REMOVE (E) TREE.
15. (N) LOT LINE ESTABLISHED UNDER PLN2023-0069.
16. (N) BIORETENTION PLANTER PER CIVIL. SHOWN FOR REF. ONLY.
17. (N) DETENTION VAULT PER CIVIL. SHOWN FOR REF. ONLY.
18. (N) UTILITIES PER CIVIL. SHOWN FOR REF. ONLY.
19. (E) ELECTRICAL METER TO REMAIN.
20. STREET -FACING PEDESTRIAN AREA (640± SF TOTAL)
21, AT -GRADE AMENITY AREA (309± SF TOTAL)
Q22. LINE OF BALCONY ABOVE
23. 3FT. BY 20.5FT. REFUSE STAGING AREA. (EIGHT 28"x35" BINS)
24. (E) OVERHEAD ELECTRICAL SERVICE TO NEIGHBORING PARCEL
TO REMAIN. REROUTE TO (N) UTILITY POLE.
25. (N) ENTRY WALKWAY AND STAIRS. REF. A2.1 FOR DETAILS.
26. REROUTE (E) OVERHEAD ELECTRICAL LINE TO (N) UTILITY POLE.
27. SHORT-TERM BICYCLE PARKING (CYCLESAFE U/2 OR EQUAL).
A4' 28. TRASH/RECYCLING STORAGE IN PRIVATE GARAGE.
EDMONDS DESIGN STANDARDS
CODE COMPLIANCE 2018 SRC / TYPE V-B / OCC. R3 / ZONED BD2
PERMITTED USES: ALLOWED: TOWNHOUSES, RENTAL,
(ECDC 16.43.020) OFFICE, RESTAURANTS
PROPOSED: TOWNHOUSES
LOT AREA: N/A: NO REQUIREMENT
(ECDC 16.43.030.A)
LOT WIDTH: N/A: NO REQUIREMENT
(ECDC 16.43.030.A)
SETBACKS: N/A: NO REQUIREMENT
(ECDC 16.43.030.A)
STRUCTURE HEIGHT: ALLOWED: 30 FT ABV AVG (E) GRADE
(ECDC 16.43.030.A) (REF. CALC, THIS SHEET)
53.85' + 30' = 83.85'
PROPOSED: 83.85'
(REF. A3.1-A3.3)
GROUND FLOOR HEIGHT: N/A: SITE NOT LOCATED IN
(ECDC 16.43.030.A) DESIGNATED FRONTAGE
GROUND FLOOR ELEV.: N/A: SITE NOT LOCATED IN
(ECDC 16.43.030.B.5) DESIGNATED FRONTAGE
GROUND FLOOR USES: N/A: SITE NOT LOCATED IN
(ECDC 16.43.030.B.7) DESIGNATED FRONTAGE
(ECDC 16.43.030.B.10.E)
OPEN SPACE: N/A: OPEN SPACE REQ'S
(ECDC 16.43.030.E) APPLY TO LOTS IN EXCESS
OF 12,000 SF AND TO BLGS
WITH STREET FRONTAGE
EXCEEDING 120 FT IN
WIDTH. NEITHER IS TRUE
OF THIS PROJECT.
DENSITY: N/A: NO LIMIT
(ECDC 16.43.030.F)
SCREENING: N/A: SITE IS NOT ADJACENT TO
(ECDC16.43.030.H) Q - _ R-ZONED PROPERTY
PARKING:
REQUIRED:
1 SPACE PER UNIT
(ECDC 17.50.010.C)
(4) UNITS x 1 = (4)
SPACES REQ'D
PROPOSED:
(6) SPACES PROVIDED
EXTERIOR MATERIALS:
REQUIRED:
EXTERIOR MATERIALS TO
(ORD. 4256 22.43.080.13)
BE STONE, WOOD, GLASS,
ARCH'L METAL AND/OR
BRICK. OTHER MATERIALS
WHICH REPLICATE THE
APPEARANCE OF THESE
MATERIALS MAY BE USED.
PROPOSED:
EXTERIOR MATERIALS
INCLUDE BRICK, CEDAR
LAP SIDING, VERT. PLANK
SIDING AND DETAIL
PANELS. REF. A3.1-A3.3
FOR DETAILS.
PRIVATE AMENITY SPACE:
REQUIRED:
AMENITY AREAS EQUAL
(ORD. 4256 22.43.080.C)
TO 10% OF LOT AREA
0.10*4641 =464SF
PROPOSED:
AT -GRADE: 309± SF
ROOF MODULATION:
(ORD. 4256 22.43.080.D)
PEDESTRIAN AREA:
(ORD. 4256 22.43.080.E)
rYCLE PARKINGD. 4277)
BALCONIES: 367± SF
TOTAL: 676± SF
REF. A2.2-A2.3 FOR /2
BALCONY LOCATIONS
REQUIRED:
ROOF MODULATION REQ'D
PROPOSED:
THE ROOF IS DIVIDED INTO
THREE SEGMENTS,
PROVIDING REQ'D
MODULATION. REF.
A3.1-A3.3 FOR DETAILS.
REQUIRED:
PEDESTRIAN AMENITY
AREA EQUAL TO 5% OF LOT
Q
AREA LOCATED ALONG
THE STREET.
0.05*4641 =232SF
PROPOSED: t
640± SF LANDSCAPED
AREA LOCATED BETWEEN
THE BUILDING AND THE
STREET.
REQUIRED:
1 SHORT-TERM SPACE
PER 10 UNITS. LONG-
TERM SPACES NOT REQ'D
PER TBL 17.120-2 NOTE 1.
PROPOSED:
(2) SHORT-TERM SPACES
SCOPE OF WORK
CONSTRUCT (4) TOWNHOUSES TOTAL. (2) TOWNHOUSES TO
CONTAIN 1774± SF LIVING AREA AND 383± SF GARAGE (EA.)
AND (2) TOWNHOUSES TO CONTAIN 1407± SF LIVING AREA
AND 303± SF GARAGE (EA.). CONSTRUCT SITE IMPROVEMENTS
INCLUDING BUT NOT LIMITED TO STORM DRAINAGE,
WALKWAYS AND SITE STAIRS.
(E) DUPLEX TO BE DEMOLISHED UNDER SEPARATE PERMIT.
ESTABLISH USE AND OCCUPY, PER PLANS.
PROJECT INFO.
SITE ADDRESS
310 DALEY STREET
EDMONDS, WA 98020
ZONING AND LAND AREA
ZONING: BD-2
LOT AREA: 4641 SF
PARCEL MAP NUMBER
004342-026-001-01
LEGAL DESCRIPTION
LOTS 1, 2.3. AND 4, BLOCK J, CITY OF EDMONDS, ACCORDING TO
THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE
39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
EXCEPT THE SOUTH 60 FEET THEREOF.
JURISDICTION
EDMONDS, SNOHOMISH COUNTY, WASHINGTON
BUILDING INFORMATION
OCCUPANCY: R-3 (TOWNHOUSES)
CONSTRUCTION: VB
FIRE SUPPRESSION: NFPA 13D THROUGHOUT
SEPA COMPLIANCE
APPLICABLE SEPA THRESHOLD IS (4) DWELLING UNITS.
THIS PROJECT CONTAINS (4) DWELLING UNITS AND IS
CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW
PROJECT NUMBERS
UNIT A BUILDING PERMIT (THIS PERMIT): BLD2022-1329
UNIT B BUILDING PERMIT: BLD2022-1325
UNIT C BUILDING PERMIT: BLD2022-1326
UNIT D BUILDING PERMIT: BLD2022-1327
DEMOLITION PERMIT: BLD2022-1328
PRELIMINARY SHORT PLAT: PLN2023-0069
RIGHT-OF-WAY CONSTRUCTION: BLD2023-0473
FILL/GRADE PERMIT BLD2024-0804
PROJECT DIRECTORY
OWNER AND DEVELOPER
HBRE INVESTMENTS
1951 3RD AVENUE W
SEATTLE, WA 98119
DESIGNER AND APPLICANT
CITIZEN DESIGN
10 DRAVUS STREET
SEATTLE, WA 98109
CONTACT: JACOB YOUNG
TEL: 206.853.8055
EMAIL:
JYOU NG@COLLABORATIVECO.COM
STRUCTURAL ENGINEER
BUILT ENGINEERING
534 BROADWAY #305
TACOMA, WA 98402
CONTACT: BRICE PARRISH
TEL: 253.985.5008
EMAIL: BRICE@BUILTSTRUCTURAL.COM
CIVIL ENGINEER
DAVIDO CONSULTING GROUP
15029 BOTHELL WAY NE #600
LAKE FOREST PARK, WA 98155
CONTACT: TIM GABELEIN, PE
TEL: 206.523.0024
EMAIL: TIM@DCGENGR.COM
SURVEY
CHADWICK + WINTERS
1422 NW 85TH STREET
SEATTLE, WA 98117
CONTACT: BRANDON WINTERS
TEL: 206.297.0996
EMAIL: BRANDONW@CHADWICKWINTERS.COM
LANDSCAPE ARCHITECT
CRAMER DESIGN CONSULTANTS
1909 242ND STREET SE
BOTHELL, WA 98021
CONTACT: GAYLE CRAMER
TEL: 425.241.6258
EMAIL: CDCLSA@FRONTIER.COM
ARBORIST
LAYTON TREE CONSULTING
PO BOX 572
SNOHOMISH, WA 98291
CONTACT: BOB LAYTON
TEL: 425.220.5711
EMAIL: BOB@LAYTONTREECONSULTING.COM
GENERAL CONTRACTOR
SEATTLE LUXURY HOMES, LLC
PO BOX 1478
EDMONDS, WA 98020
LIC. NO.: SEATTLH822JB
CONTACT: JOHNATHAN KURTH
T: 206.579.5272
E: JOHNATHAN.KURTH@GMAIL.COM
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
f
f
f
f
W
�
"' •
M 0
` =
o
N
fl Zo
00
`
f
O�1
z
Z
O
O
W
"'
J
W
aW
ul
ul
W
f
O
CM
O
M
r City of EDMONDS
r Permit Set
r October 7, 2022
ARevision 1
` z2 Revision 2
f
` 33 Revision 3
f
Revision 4
Revision 5
r A Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
ZONING
SITE PLAN
SCALE: AS NOTED
A005
/
/
/
408 3RD AVENUE N
APN:004342-119-038-00
ZONED: RS-6 / / QC O 55 _
O� `Po.
b,
�°k
CENTERLINE MONUMENT
FOUND EXISTING
MONUMENT IN CASE ON
JULY 27, 2021
N=300,639.0910
E=1,260,998.0680
30'-0" HALF ROW
ARCHITECTURAL SITE PLAN
SCALE: I" = 10'
24'-0" BACKING DISTANCE
c v
DSI7I v°
l v
vol
G
I
�. +I
v O
I� n L16
v. Io 1
00
I, v LO
v o _
I ; N
O
v M
t �
G
°
L`
°
I°
Q a
v
DS
a
° a
O °
° v ❑ W
24'-( FSD
Q
G
v_
0 3
Off, p1
i
25" ET 2
I \
I \
305 4TH AVENUE N
AP N : 004342-026-005-00
ZONED: BD-5
I
I
303 4TH AVENUE N
AP N : 004342-026-009-01
ZONED: BD-5
p
p1
\IhllllllFFF P
\ I
�P
O P�-
16'-0" ALLEY'
O% A
0 5 10 20 Q
CAN 14,A �$L, r 10. ZL
TRUE PROJECT ZL
KEYNOTES
1.
(N) STREET FRONTAGE IMPROVEMENTS PER CIVIL.
(SHOWN FOR REF. ONLY)
2.
(E) TREE TO REMAIN.
3.
(N) UTILITY POLE PER CIVIL. SHOWN FOR REF. ONLY.
4.
2 FT MAX HT CONCRETE WALL PER STRUCTURAL.
5.
4 FT WIDE CONCRETE WALK PER CIVIL.
6.
4 FT WIDE SITE STAIRS OR @ 6", 2T @12").
7.
8.5 FT x 16.5 FT PARKING SPACE.
8.
(N) TREE PER LANDSCAPE. SHOWN FOR REF. ONLY.
9.
LINE OF CANOPY (ABOVE).
10.
(N) BIORETENTION PLANTER PER CIVIL. SHOWN FOR REF. ONLY.
11.
(N) DETENTION VAULT PER CIVIL. SHOWN FOR REF. ONLY.
12.
CORNER OF BUILDING AT R.
13.
LINE OF BALCONY ABOVE
14.
(E) OVERHEAD ELEC'L AND PHONE SERVICES TO NEIGHBORING
PARCEL TO REMAIN. REROUTE TO (N) UTILITY POLE.
15.
(N) ENTRY WALKWAY AND STAIRS. REF. A2.1 FOR DETAILS.
16.
REROUTE (E) OVERHEAD ELECTRICAL LINE TO (N) UTILITY POLE.
17.
SHORT-TERM BICYCLE PARKING (CYCLESAFE U/2 OR EQUAL)
18.
PAVED AREA FOR TRASH STAGING PER CIVIL.
Z 19.
TRASH/RECYCLING STORAGE IN PRIVATE GARAGE.
SCOPE OF WORK
CONSTRUCT (4) TOWNHOUSES TOTAL. (2) TOWNHOUSES TO
CONTAIN 1774± SF LIVING AREA AND 383± SF GARAGE (EA.)
AND (2) TOWNHOUSES TO CONTAIN 1407± SF LIVING AREA
AND 303± SF GARAGE (EA.). CONSTRUCT SITE IMPROVEMENTS
INCLUDING BUT NOT LIMITED TO STORM DRAINAGE,
WALKWAYS AND SITE STAIRS.
(E) DUPLEX TO BE DEMOLISHED UNDER SEPARATE PERMIT.
ESTABLISH USE AND OCCUPY, PER PLANS.
PROJECT INFO.
SITE ADDRESS
310 DALEY STREET
EDMONDS, WA 98020
ZONING AND LAND AREA
ZONING: BD-2
LOT AREA: 4641 SF
PARCEL MAP NUMBER
004342-026-001-01
LEGAL DESCRIPTION
LOTS 1, 2.3. AND 4, BLOCK J, CITY OF EDMONDS, ACCORDING TO
THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE
39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
EXCEPT THE SOUTH 60 FEET THEREOF.
JURISDICTION
EDMONDS, SNOHOMISH COUNTY, WASHINGTON
BUILDING INFORMATION
OCCUPANCY: R-3 (TOWNHOUSES)
CONSTRUCTION: VB
FIRE SUPPRESSION: NFPA 13D THROUGHOUT
SEPA COMPLIANCE
APPLICABLE SEPA THRESHOLD IS (4) DWELLING UNITS.
THIS PROJECT CONTAINS (4) DWELLING UNITS AND IS
CATEGORICALLY EXEMPT FROM ENVIRONMENTAL REVIEW
PROJECT NUMBERS
UNIT A BUILDING PERMIT (THIS PERMIT): BLD2022-1329
UNIT B BUILDING PERMIT: BLD2022-1325
UNIT C BUILDING PERMIT: BLD2022-1326
UNIT D BUILDING PERMIT: BLD2022-1327
DEMOLITION PERMIT: BLD2022-1328
PRELIMINARY SHORT PLAT: PLN2023-0069
RIGHT-OF-WAY CONSTRUCTION: ENG2023-0473
PROJECT DIRECTORY
OWNER AND DEVELOPER
HBRE INVESTMENTS
1951 3RD AVENUE W
SEATTLE, WA 98119
DESIGNER AND APPLICANT
CITIZEN DESIGN
10 DRAVUS STREET
SEATTLE, WA 98109
CONTACT: JACOB YOUNG
TEL: 206.853.8055
EMAIL:
JYOU NG@COLLABORATIVECO.COM
STRUCTURAL ENGINEER
BUILT ENGINEERING
534 BROADWAY #305
TACOMA, WA 98402
CONTACT: BRICE PARRISH
TEL: 253.985.5008
EMAIL: BRICE@BUILTSTRUCTURAL.COM
CIVIL ENGINEER
DAVIDO CONSULTING GROUP
15029 BOTHELL WAY NE #600
LAKE FOREST PARK, WA 98155
CONTACT: TIM GABELEIN, PE
TEL: 206.523.0024
EMAIL: TIM@DCGENGR.COM
SURVEY
CHADWICK + WINTERS
1422 NW 85TH STREET
SEATTLE, WA 98117
CONTACT: BRANDON WINTERS
TEL: 206.297.0996
EMAIL: BRANDONW@CHADWICKWINTERS.COM
LANDSCAPE ARCHITECT
CRAMER DESIGN CONSULTANTS
1909 242ND STREET SE
BOTHELL, WA 98021
CONTACT: GAYLE CRAMER
TEL: 425.241.6258
EMAIL: CDCLSA@FRONTIER.COM
ARBORIST
LAYTON TREE CONSULTING
PO BOX 572
SNOHOMISH, WA 98291
CONTACT: BOB LAYTON
TEL: 425.220.5711
EMAIL: BOB@LAYTONTREECONSULTING.COM
GENERAL CONTRACTOR
SEATTLE LUXURY HOMES, LLC
PO BOX 1478
EDMONDS, WA 98020
LIC. NO.: SEATTLH822JB
CONTACT: JOHNATHAN KURTH
T: 206.579.5272
E: JOHNATHAN.KURTH@GMAIL.COM
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Zo
00
Z 0%
O
z
z
O
O
W "'
W J
aW
H
ul
O a
r C3
0
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
A2
Revision 2
04/03/23
ARevision
3
09/15/23
Revision 4
02/05/24
Revision 5
06/10/24
A6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ARCHITECTURAL
SITE PLAN
SCALE: AS NOTED
Al
■
407 3RD AVE N
405 3RD AVE N
388 3RD AVE N
411c
7A
A
BREAKWATER
CONDOS
NEIGHBORING PROJECT SITE
XE
304DALEY ST ——————————————————————————————
UNDER SEPARATE PERMIT y�i+
BELLA SOUL
HAIR DESIGN
303 BEACHWALK
303 EDMONDS STft
low , i ....
t MEOW'
234 2ND AVE N
228 2ND AVE N
-tom_
.;
LA F/
CONDOMINIU
VICINITY MAP
SCALE: NTS
HOCHBER(
HAMAR, PL
) 3RD AVENUE S
i
TON FAMILY
DICINE
rid
225 5TH AVE N
- T__A� -0
�e
l �..
r' • ' kay; ti
)MONDS MUNICIPAL
)URT
EDMONDS CENTER
FOR THE ARTS
416 DALEY ST
WIMBLEDON
411 6TH AVE N
318 DALEY ST
EDMONDS
APARTMENTS
PROJECT SITE EXTENTS
-i 310 DALEY ST
TOWNHOMES
EDMONDS
HEALTH CLINIC
233 5TH AVE N
CITIZEN
� DESIGN
M
RES U 6
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
f
w
M
O
O
N
Z00
p
z
z
0
o
W
w
3333333J
w
aw
M
o�
o0
w
M
�o
CM
M
r
City of EDMONDS
Permit
Set
October 7, 2022
M
Revision 1
10/21/22
` A�
Revision 2
04/03/23
f
` ZL
Revision 3
09/15/23
f
A
Revision 4
02/05/24
55
Revision 5
06/10/24
r A6
Reviginn A
nA/99/2L
FOR PLANNING DEPT USE ONLY
r
VICINITY MAP
SCALE: AS NOTED
Al
■
m
OIW
I' ol
_ ao' r
a
_s
-I '
M •
-�
r
�tl _-Ilmrm -409pm -qlwm _41110M
-411opm
_1110mm -quom -sopm
: t:T ! ==WT s =MS ! =IN!
-1 'a!
I =a-- ! =W— ! "W' /
•- �- �� - sTr s- •= s-- r=
�c- s
�c- �= s- t= s- •:
3z .als AddOM 401011M 408MBM
-ems --ems --� -•'`mac
4MMMMk=
--'`mac
. ass ..s/Cs aAdlks
- -•des •'�s - �
„
1 ^ • c
• ►iz
• .'Wi / •t f
f�t�t�♦�f�f�f�f ~� �
NWAM • 11111sm •ems 9111r6m
wap-s
ow-M wmp6m elp-i
M���MP# �aW
s •t- • r- ► W- • W- •
Mtg� : Mj 1 - 4kfdbW 4bfi�
Ir ►
. AkAdWM
w 0 or ► w •
psi 4949" . •aeltS
i P �� �
�i�
lqw - Asa one 1
r
A 1 1
JL
• � • • to • • � • •
�
mil _ ../f. r . 1 . , r
1 t
• I • to • •
w . -. • A
• w��
- i -- i
., a;
, 0-1 , f - t
W •
• i - i i
i
1
RiM
r
' Z
0
WE
LEGEND
0
PARTY WALL A
1-HR RATED PER IRC R302.2.2.1
0
2x6 FRAMED WALL
O
2x4 FRAMED WALL
SPOT ELEVATION
❑X
NOTE CALLOUT
OX
DOOR CALLOUT
OX
WINDOW CALLOUT
EG = EGRESS
SG = SAFETY GLAZING
SCUPPER
0DS
DOWNSPOUT
PLAN NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
3. SEE "S" SHEET SERIES FOR LATERAL INFORMATION AND ENGINEERING DETAILS.
4. ALL INTERIOR WALLS W4 AND 2x4 U.N.O.
5. ALL EXTERIOR WALLS W1 AND 2x6 U.N.O.
6. GIVEN WINDOW DIMENSIONS ARE TO ROUGH OPENINGS. FINISH OPENING PER MFR.
7. GIVEN DOOR DIMENSIONS ARE TO DOOR PANEL. ROUGH OPENINGS PER MFR.
8. ALL DOORS SHALL BE CENTERED ON WALL OR 3" FROM ADJACENT WALL U.N.O.
9. ALL OPERABLE WINDOWS SHALL HAVE SCREENS AND BE CONTROLLABLE AND
SECURABLE PER IRC M1507.3.4.4.
10. ALL EXHAUSTS SHALL TERMINATE NOT LESS THAN 3 FT FROM PROPERTY LINES; 3 FT
FROM OPERABLE/NON-OPERABLE OPENINGS INTO BUILDING AND 10 FT FROM
MECHANICAL AIR INTAKES, EXCEPT WHERE OPENING IS 3 FT ABOVE AIR INTAKE PER
IRC M1506.3.
11. SEE DETAILS 3/A5.3 & 4/A5.3 FOR STAIR & RAILING REQUIREMENTS.
12. CASEWORK NOT IN CONTRACT. REFER TO CASEWORK SHOP DRAWINGS FOR
DIMENSIONS AND DETAILS.
13. SMOKE ALARMS/DETECTORS SHALL BE INSTALLED IN ALL SLEEPING ROOMS, IN THE
AREA OUTSIDE THE SLEEPING ROOM AND IN OTHER LOCATIONS PER IRC SECTION R314.
ELECTRICAL POWER AND INTERCONNECTION PER CODE.
SMOKE DETECTOR: so
14. CARBON MONOXIDE DETECTORS SHALL BE LOCATED OUTSIDE OF ALL SLEEPING
ROOMS AND ON EACH LEVEL.
CARBON MONOXIDE DETECTOR: co
COMBO SMOKE/CARBON MONOXIDE DETECTOR: g
15. INSTALL HEAT DETECTOR IN GARAGE. DETECTOR SHALL BE RATED FOR AMBIENT
TEMPERATURE AND HUMIDITY AND SHALL BE INSTALLED PER MANUFACTURER'S
INSTRUCTIONS. HEAT DETECTOR: Ho
16. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN EVERY
SLEEPING ROOM BELOW THE 4TH STORY PER 2018 IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
13. SAFETY GLAZING REQUIRED PER IRC 308.4.
14. WALLS AND SOFFITS OF ENCLOSED SPACES UNDER STAIRS SHALL BE PROTECTED ON
THE ENCLOSED SIDE WITH A MINIMUM OF)/2" GYPSUM BOARD AS REQUIRED BY IRC
R302.7.
15. MECHANICAL SYSTEM SHALL BE DESIGN -BUILD.
16. LOCAL EXHAUST FANS:
50 CFM (MIN) ON SWITCH A
QQ 100 CFM (MIN) ON TIMER (WHOLE HOUSE FAN, 66% RUNTIME MIN.)
Q 100 CFM (MIN) RANGE HOOD ON SWITCH
17. PER WASHINGTON STATE ENERGY CODE, RESIDENTIAL FOR MEDIUM RESIDENCE,
6.0 CREDITS ARE REQUIRED. THE FOLLOWING CREDITS ARE PURSUED:
• FUEL NORMALIZATION OPTION 2: DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM (1.0
CREDIT)
• OPTION 1.3: EFFICIENT BUILDING ENVELOPE (0.5 CREDIT)
• OPTION 2.1: REDUCED AIR LEAKAGE AND EFFICIENT VENTILATION (0.5 CREDIT)
Q• OPTION 3.6: HIGH EFFICIENCY HVAC EQUIPMENT (2.0 CREDITS)
.� • OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER (2.0 CREDITS)
t REF. MECHANICAL & ENERGY NOTES, A0.1. FOR DETAILS
22. BACKUP HEATERS MAY BE INSTALLED PURSUANT TO WSEC TABLE 406.3 NOTE 2.
TOTAL INSTALLED WATTAGE SHALL BE 0.5 WATTS PER SF OR 500W, WHICHEVER IS
LARGER.
23. ELECTRICAL PANEL LOCATION.
24. EXHAUST VENT TO EXTERIOR.
25. HEAT PUMP WATER HEATER PER MFR.
26. VENT EXHAUST THROUGH ROOF.
27. 8'-6"x16'-6" PARKING SPACE.
28. MINI -SPLIT HEAD.
29. MINI -SPLIT COMPRESSOR.
30. LINE OF CANOPY ABOVE PER DETAIL 5/A5.3.
31. DOORS BETWEEN GARAGE AND LIVING SPACES SHALL HAVE A 20 MINUTE FIRE
RESISTANCE RATING AND SHOULD BE EQUIPPED WITH A SELF CLOSING DEVICE.
32. DROPPED SOFFIT ABOVE.
33. LINE OF ROOF ABOVE.
34. BIORETENTION PLANTER PER C04.
35, GUTTER PER DETAIL 4/A5.4
Q36. LINE OF BALCONY ABOVE, BY OTHERS UNDER DEFERRED REVIEW
37. GUARDRAIL PER DETAIL 3/A5.4
38. LINE OF BALCONY BELOW, BY OTHERS UNDER DEFERRED REVIEW
39. "EV READY" PARKING SPACES SHALL BE PROVIDED WITH A FULLY WIRED CIRCUIT
WITH A LEVEL II OR LEVEL III ELECTRIC VEHICLE CHARGING RECEPTACLE OR
TERMINAL, INCLUDING CONDUIT, WIRING AND THE ELECTRICAL SERVICE CAPACITY
NECESSARY TO SERVE THE RECEPTACLE ALLOWING FUTURE INSTALLATION OF AN
A
ELECTRIC VEHICLE CHARGING STATION.
40. CONCRETE SITE STAIRS AND ENTRY WALKWAY
41. PROVIDE SOLID BALCONY ABOVE ENTRY DOOR PER DETAIL 3/A5.4
1'-6"
3'-6 1 /2"
FIRST FLOOR PLAN
SCALE: 1 /4" = 1 '-0"
UNIT
18'-11"
16'-0"
(D
16070
UNIT B
15'-0"
3
67'-10"
i
1
A3.2
12'-0" " 1'-6"1'-6",
------------- ----30
O T`
12070
53 I 1 U u5l �� 3 \k4)_ J L-- I
2630 (SG) 3070 i i 4040 30 2040 29 29 204(
I --- -J
- 2'4"-V-9"-/1'-3/- - 3'-0" 2'-8" 4'4" 2'4" 2'-1" i 2'-1" 2'-0
UNIT
15'-0"
12'-0"
12070
16-0"
O
16070
'-3;/- 4'4"
W
TRUE
1 '-6" iV-
0 2
00 A3.3
-1 29 1
L_ J
C..
PROJECT
0 2 4 8
1 /4" = 1 '-0"
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v I
,W
v I
0
o
N
Zo
00
0%
0
O
Z
O
O
LU "'
J W
Q w
ul
W
0 0
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ZN
Revision 1
10/21/22
Revision 2
04/03/23
Revision 3
09/15/23
Revision 4
02/05/24
A5
Revision 5
06/10/24
6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
FIRST
FLOOR PLAN
SCALE: AS NOTED
A201
LEGEND T
A4.2 A3.2
UNIT A 1 2 2 UNIT B 3 UNIT C 1 4 2
A4.2 A4.3 A4.3
0 PARTY WALL Q
1-HR RATED PER IRC R302.2.2.1)67'-10" -
0 2x6 FRAMED WALL 01 01 18'-11 " 15'-0" 15'-0" -
O 2x4 FRAMED WALL 5'-11" 9'-1" 9'-1" 5'-11" -
SPOT ELEVATION lo
�X NOTE CALLOUT 6'-0" V-7" 4'-0" T-11" 4'-0" - 1'-5"- 3'-11 �� 3'-6" Ty � 2'-7" -X- 2'-7" 3'-6" 3'-0" V-5" -
NDS � 6" GUTTER DS N
OX DOOR CALLOUT • _ _ - •
35
OX WINDOW CALLOUT - - -
EG = EGRESS
SG -SAFETY GLAZING A DS 4066 4066 I • DS , i �_ - _ 3646 = _ ,T� ,T� 3646 - , i DS •
•
SCUPPER PTRY I DW l l I PTRY
•DS
DOWNSPOUT Nil , I �11 i 11 1 DW
PLAN NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
3. SEE "S" SHEET SERIES FOR LATERAL INFORMATION AND ENGINEERING DETAILS.
4. ALL INTERIOR WALLS W4 AND 2x4 U.N.O.
5. ALL EXTERIOR WALLS W1 AND 2x6 U.N.O.
6. GIVEN WINDOW DIMENSIONS ARE TO ROUGH OPENINGS. FINISH OPENING PER MFR.
7. GIVEN DOOR DIMENSIONS ARE TO DOOR PANEL. ROUGH OPENINGS PER MFR.
8. ALL DOORS SHALL BE CENTERED ON WALL OR 3" FROM ADJACENT WALL U.N.O.
9. ALL OPERABLE WINDOWS SHALL HAVE SCREENS AND BE CONTROLLABLE AND
SECURABLE PER IRC M1507.3.4.4.
10. ALL EXHAUSTS SHALL TERMINATE NOT LESS THAN 3 FT FROM PROPERTY LINES; 3 FT
FROM OPERABLE/NON-OPERABLE OPENINGS INTO BUILDING AND 10 FT FROM
MECHANICAL AIR INTAKES, EXCEPT WHERE OPENING IS 3 FT ABOVE AIR INTAKE PER
IRC M1506.3.
11. SEE DETAILS 3/A5.3 & 4/A5.3 FOR STAIR & RAILING REQUIREMENTS.
12. CASEWORK NOT IN CONTRACT. REFER TO CASEWORK SHOP DRAWINGS FOR
DIMENSIONS AND DETAILS.
13. SMOKE ALARMS/DETECTORS SHALL BE INSTALLED IN ALL SLEEPING ROOMS, IN THE
AREA OUTSIDE THE SLEEPING ROOM AND IN OTHER LOCATIONS PER IRC SECTION R314.
ELECTRICAL POWER AND INTERCONNECTION PER CODE.
SMOKE DETECTOR: so
14. CARBON MONOXIDE DETECTORS SHALL BE LOCATED OUTSIDE OF ALL SLEEPING
ROOMS AND ON EACH LEVEL.
CARBON MONOXIDE DETECTOR: co
COMBO SMOKE/CARBON MONOXIDE DETECTOR: g
15. INSTALL HEAT DETECTOR IN GARAGE. DETECTOR SHALL BE RATED FOR AMBIENT
TEMPERATURE AND HUMIDITY AND SHALL BE INSTALLED PER MANUFACTURER'S
INSTRUCTIONS. HEAT DETECTOR: Ho
16. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN EVERY
SLEEPING ROOM BELOW THE 4TH STORY PER 2018 IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
13. SAFETY GLAZING REQUIRED PER IRC 308.4.
14. WALLS AND SOFFITS OF ENCLOSED SPACES UNDER STAIRS SHALL BE PROTECTED ON
THE ENCLOSED SIDE WITH A MINIMUM OF)/2" GYPSUM BOARD AS REQUIRED BY IRC
R302.7.
15. MECHANICAL SYSTEM SHALL BE DESIGN -BUILD.
16. LOCAL EXHAUST FANS:
50 CFM (MIN) ON SWITCH A
QQ 100 CFM (MIN) ON TIMER (WHOLE HOUSE FAN, 66% RUNTIME MIN.)
Q 100 CFM (MIN) RANGE HOOD ON SWITCH
17. PER WASHINGTON STATE ENERGY CODE, RESIDENTIAL FOR MEDIUM RESIDENCE,
6.0 CREDITS ARE REQUIRED. THE FOLLOWING CREDITS ARE PURSUED:
• FUEL NORMALIZATION OPTION 2: DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM (1.0
CREDIT)
• OPTION 1.3: EFFICIENT BUILDING ENVELOPE (0.5 CREDIT)
• OPTION 2.1: REDUCED AIR LEAKAGE AND EFFICIENT VENTILATION (0.5 CREDIT)
• OPTION 3.6: HIGH EFFICIENCY HVAC EQUIPMENT (2.0 CREDITS)
1 • OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER (2.0 CREDITS)
t REF. MECHANICAL & ENERGY NOTES, Ai FOR DETAILS
22. BACKUP HEATERS MAY BE INSTALLED PURSUANT TO WSEC TABLE 406.3 NOTE 2.
TOTAL INSTALLED WATTAGE SHALL BE 0.5 WATTS PER SF OR 500W, WHICHEVER IS
LARGER.
23. ELECTRICAL PANEL LOCATION.
24. EXHAUST VENT TO EXTERIOR.
25. HEAT PUMP WATER HEATER PER MFR.
26. VENT EXHAUST THROUGH ROOF.
27. 8'-6"x16'-6" PARKING SPACE.
28. MINI -SPLIT HEAD.
29. MINI -SPLIT COMPRESSOR.
30. LINE OF CANOPY ABOVE PER DETAIL 5/A5.3.
31. DOORS BETWEEN GARAGE AND LIVING SPACES SHALL HAVE A 20 MINUTE FIRE
RESISTANCE RATING AND SHOULD BE EQUIPPED WITH A SELF CLOSING DEVICE.
32. DROPPED SOFFIT ABOVE.
33. LINE OF ROOF ABOVE.
34. BIORETENTION PLANTER PER C04.
35. GUTTER PER DETAIL 4/A5.4
A
36. LINE OF BALCONY ABOVE, BY OTHERS UNDER DEFERRED REVIEW
37. GUARDRAIL PER DETAIL 3/A5.4
38. LINE OF BALCONY BELOW, BY OTHERS UNDER DEFERRED REVIEW
39. "EV READY" PARKING SPACES SHALL BE PROVIDED WITH A FULLY WIRED CIRCUIT
WITH A LEVEL II OR LEVEL III ELECTRIC VEHICLE CHARGING RECEPTACLE OR
TERMINAL, INCLUDING CONDUIT, WIRING AND THE ELECTRICAL SERVICE CAPACITY
NECESSARY TO SERVE THE RECEPTACLE ALLOWING FUTURE INSTALLATION OF AN
QELECTRIC VEHICLE CHARGING STATION.
40. CONCRETE SITE STAIRS AND ENTRY WALKWAY
41. PROVIDE SOLID BALCONY ABOVE ENTRY DOOR PER DETAIL 3/A5.4
SECOND FLOOR PLAN
SCALE: 1 /4" = 1 '-0"
6-II ?r
15'-0"
67' 10"
3
1
A3.1
15'-0"
UNIT D
18'-11"
TRUE
C..
PROJECT
0 2 4 8
1 /4" = 1 '-0"
0
co
M
2
A3.3
1
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v I
,W
v I
0
o
N
Zo
eo
0%
0
O
Z
O
O
LU "'
J W
Q w
ul
W
0 Q
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
ZL
Revision 2
04/03/23
ARevision
3
09/15/23
Revision 4
02/05/24
A5
Revision 5
06/10/24
6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
SECOND
FLOOR PLAN
SCALE: AS NOTED
A202
LEGEND
0 PARTY WALL A
1-HR RATED PER IRC R302.2.2.1
I 2x6 FRAMED WALL
O 2x4 FRAMED WALL
SPOT ELEVATION
❑X NOTE CALLOUT
ODOOR
CALLOUT
O
WINDOW CALLOUT
EG = EGRESS
SG = SAFETY GLAZING
SCUPPER
0DS DOWNSPOUT
PLAN NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
3. SEE "S" SHEET SERIES FOR LATERAL INFORMATION AND ENGINEERING DETAILS.
4. ALL INTERIOR WALLS W4 AND 2x4 U.N.O.
5. ALL EXTERIOR WALLS W1 AND 2x6 U.N.O.
6. GIVEN WINDOW DIMENSIONS ARE TO ROUGH OPENINGS. FINISH OPENING PER MFR.
7. GIVEN DOOR DIMENSIONS ARE TO DOOR PANEL. ROUGH OPENINGS PER MFR.
8. ALL DOORS SHALL BE CENTERED ON WALL OR 3" FROM ADJACENT WALL U.N.O.
9. ALL OPERABLE WINDOWS SHALL HAVE SCREENS AND BE CONTROLLABLE AND
SECURABLE PER IRC M1507.3.4.4.
10. ALL EXHAUSTS SHALL TERMINATE NOT LESS THAN 3 FT FROM PROPERTY LINES; 3 FT
FROM OPERABLE/NON-OPERABLE OPENINGS INTO BUILDING AND 10 FT FROM
MECHANICAL AIR INTAKES, EXCEPT WHERE OPENING IS 3 FT ABOVE AIR INTAKE PER
IRC M1506.3.
11. SEE DETAILS 3/A5.3 & 4/A5.3 FOR STAIR & RAILING REQUIREMENTS.
12. CASEWORK NOT IN CONTRACT. REFER TO CASEWORK SHOP DRAWINGS FOR
DIMENSIONS AND DETAILS.
13. SMOKE ALARMS/DETECTORS SHALL BE INSTALLED IN ALL SLEEPING ROOMS, IN THE
AREA OUTSIDE THE SLEEPING ROOM AND IN OTHER LOCATIONS PER IRC SECTION R314.
ELECTRICAL POWER AND INTERCONNECTION PER CODE.
SMOKE DETECTOR: @
14. CARBON MONOXIDE DETECTORS SHALL BE LOCATED OUTSIDE OF ALL SLEEPING
ROOMS AND ON EACH LEVEL.
CARBON MONOXIDE DETECTOR: co
COMBO SMOKE/CARBON MONOXIDE DETECTOR: CSC
15. INSTALL HEAT DETECTOR IN GARAGE. DETECTOR SHALL BE RATED FOR AMBIENT
TEMPERATURE AND HUMIDITY AND SHALL BE INSTALLED PER MANUFACTURER'S
INSTRUCTIONS. HEAT DETECTOR: H@
16. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN EVERY
SLEEPING ROOM BELOW THE 4TH STORY PER 2018 IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
13. SAFETY GLAZING REQUIRED PER IRC 308.4.
14. WALLS AND SOFFITS OF ENCLOSED SPACES UNDER STAIRS SHALL BE PROTECTED ON
THE ENCLOSED SIDE WITH A MINIMUM OF%" GYPSUM BOARD AS REQUIRED BY IRC
R302.7.
15. MECHANICAL SYSTEM SHALL BE DESIGN -BUILD.
16. LOCAL EXHAUST FANS:
50 CFM (MIN) ON SWITCH A
100 CFM (MIN) ON TIMER (WHOLE HOUSE FAN, 66% RUNTIME MIN.)
100 CFM (MIN) RANGE HOOD ON SWITCH
17. PER WASHINGTON STATE ENERGY CODE, RESIDENTIAL FOR MEDIUM RESIDENCE,
6.0 CREDITS ARE REQUIRED. THE FOLLOWING CREDITS ARE PURSUED:
• FUEL NORMALIZATION OPTION 2: DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM (1.0
CREDIT)
• OPTION 1.3: EFFICIENT BUILDING ENVELOPE (0.5 CREDIT)
• OPTION 2.1: REDUCED AIR LEAKAGE AND EFFICIENT VENTILATION (0.5 CREDIT)
• OPTION 3.6: HIGH EFFICIENCY HVAC EQUIPMENT (2.0 CREDITS)
1 OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER (2.0 CREDITS)
t REF. MECHANICAL & ENERGY NOTES, A0.1, FOR DETAILS
22. BACKUP HEATERS MAY BE INSTALLED PURSUANT TO WSEC TABLE 406.3 NOTE 2.
TOTAL INSTALLED WATTAGE SHALL BE 0.5 WATTS PER SF OR 500W, WHICHEVER IS
LARGER.
23. ELECTRICAL PANEL LOCATION.
24. EXHAUST VENT TO EXTERIOR.
25. HEAT PUMP WATER HEATER PER MFR.
26. VENT EXHAUST THROUGH ROOF.
27. 8'-6"x16'-6" PARKING SPACE.
28. MINI -SPLIT HEAD.
29. MINI -SPLIT COMPRESSOR.
30. LINE OF CANOPY ABOVE PER DETAIL 5/A5.3.
31. DOORS BETWEEN GARAGE AND LIVING SPACES SHALL HAVE A 20 MINUTE FIRE
RESISTANCE RATING AND SHOULD BE EQUIPPED WITH A SELF CLOSING DEVICE.
32. DROPPED SOFFIT ABOVE.
33. LINE OF ROOF ABOVE.
34. BIORETENTION PLANTER PER C04.
35, GUTTER PER DETAIL 4/A5.4
A
36. LINE OF BALCONY ABOVE, BY OTHERS UNDER DEFERRED REVIEW
37. GUARDRAIL PER DETAIL 3/A5.4
38. LINE OF BALCONY BELOW, BY OTHERS UNDER DEFERRED REVIEW
39. "EV READY" PARKING SPACES SHALL BE PROVIDED WITH A FULLY WIRED CIRCUIT
WITH A LEVEL II OR LEVEL III ELECTRIC VEHICLE CHARGING RECEPTACLE OR
TERMINAL, INCLUDING CONDUIT, WIRING AND THE ELECTRICAL SERVICE CAPACITY
NECESSARY TO SERVE THE RECEPTACLE ALLOWING FUTURE INSTALLATION OF AN
QELECTRIC VEHICLE CHARGING STATION.
40. CONCRETE SITE STAIRS AND ENTRY WALKWAY
41. PROVIDE SOLID BALCONY ABOVE ENTRY DOOR PER DETAIL 3/A5.4
THIRD FLOOR PLAN
SCALE: 1 /4" = 1 '-0"
PROJECT
0 2 4 8
1 /4" 1 '-0"
2
A3.3
1
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v
`W
v
0
o
N
Zao
Z 0�
0
Z
O
O
W "'
J
w
aw
F-
LU
0 Q
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
2�
Revision 2
04/03/23
ARevision
3
09/15/23
Revision 4
02/05/24
ARevision
5
06/10/24
66
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
THIRD
FLOOR PLAN
SCALE: AS NOTED
A203
ROOF LEGEND
I ROOF
C WALL BELOW
C = ROOF VENT
NOTE CALLOUT
0DS DOWNSPOUT
ROOF NOTES
PROVIDE SOLID BLOCKING OVER SUPPORTS
2.
FLASHING SHALL BE INSTALLED IN SUCH A MANNER AS TO PREVENT MOISTURE
ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH
MOISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET
WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. METAL
FLASHING SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS
THAN 0.0019 INCH PER IRC.
3.
EXHAUST VENT TYP., PER DETAIL 8/A5.4.
A
4,
5.
12" 0 TURBINE VENT (EMPIRE TV12G OR EQUAL), PER DETAIL 12/A5.4.
PROVIDE FIRE -RETARDANT -TREATED SHEATHING FOR 4'-0" EACH SIDE OF PARTY
WALL. REF. 7/A5.3 FOR DETAILS.
ROOF VENT CALCULATIONS
MIN. OF 1" CLEAR VENT SPACE REQ'D ABOVE CEILING INSULATION TO PROVIDE
ADEQUATE CROSS VENTILATION.
(2) OUTER UNIT ROOFS
ROOF AREA: 718.83 SF
REQ'D VENT AREA: 718.83 SF / 300 = 2.4 SF REQ'D = 345.6 SI REQ'D
38 LF CONT. ZERO-EAVE VENT (COR-A-VENT S-400 SOFFIT VENT OR EQUAL):
38 LF x 10 SI/LF = 380 SI
(2) TURBINE VENTILATORS (EMPIRE TV12G OR EQUAL);
2x(6x6x3.14)=226.08S1
TOTAL VENT AREA: 606.08 SI
(2) INNER UNIT ROOFS
ROOF AREA: 570 SF
REQ'D VENT AREA: 570 SF / 300 = 1.9 SF REQ'D = 273.6 SI REQ'D
30 LF CONT. SOFFIT VENT (COR-A-VENT S-400 SOFFIT VENT OR EQUAL):
30 LF x 10 SI/LF = 300 SI
(1) TURBINE VENTILATOR (EMPIRE TV12G OR EQUAL);
(6x6x3.14)=113.04S1
TOTAL VENT AREA: 413.04 SI
ROOF PLAN
SCALE: 1 /4" = 1 '-0"
UNIT
UNIT B
UNIT C
UNIT D
C..
PROJECT
0 2 4 8
1 /4" = 1 '-0"
A2A
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v I
,W
v I
0
N
Zo
eo
Z 0%
0
I- O
Z
O
O
LU "'
J W
Q W
ul
W
0 Q
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
ARevision
2
04/03/23
ARevision
3
09/15/23
A4
Revision 4
02/05/24
A5
Revision 5
06/10/24
6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ROOF PLAN
SCALE: AS NOTED
ELEVATION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4. REF. FLOOR PLANS, A2 SERIES, FOR EXTERIOR DOOR SIZES.
5. WINDOWS MARKED "EG" ARE EGRESS WINDOWS AND SHALL COMPLY WITH THE
FOLLOWING PER IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
6. WINDOWS AND DOORS MARKED "SG" SHALL BE PROVIDED WITH SAFETY GLAZING
PER IRC R308.4.
7. WINDOWS SHALL BE ANDERSON 100 SERIES (OR APPROVED EQUAL).
8. ELEVATIONS ARE ORIENTED TOWARD PROJECT NORTH. SEE Al AND A2 SHEETS FOR
REFERENCE.
9. OVERHANGING EAVE ATTACHMENT AND FABRICATION BY OTHERS.
10. LINE OF SITE STAIRS (WITHIN).
211. DISTANCE FROM BUILDING TO PROPERTY LINE VARIES. SEE All FOR DETAILS..
12, GUARDRAIL PER 3/A5.4
13. GUTTER AND DOWNSPOUT NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
14. BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
15. BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
0
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17'-0" (71.85'±)
SECOND SUBFLOOR
8'-6" (63.354)
SLAB ON GRADE
U-0" (54.85'±)
AVERAGE GRADE
4-12" (53.85'±)
0
0
M
1'-0"
�0
00
�o
bD
MATERIAL NOTES
DOORS
SPECIALTY
D-1
FRONT DOOR- BLACK FIBERGLASS
SP-1
WOOD CANOPY - CHARCOAL
SP-2
BIORETENTION PLANTER - STEEL PLATE
D-2
GARAGE DOOR - BLACK FIBERGLASS
SP-3
BOLT -ON BALCONY - BLACK
D-3
SLIDER DOOR - BLACK FIBERGLASS
SP-4
5" PLASTER LINTEL PER 3/A5.2
ROOFING
WINDOWS
R-1
STANDING SEAM METAL ROOF - BLACK
W-1
FIBERGLASS WINDOWS - BLACK
R-2
HARDIE SOFFIT, LIGHT GRAY
DOWNSPOUT
SIDING
DS-1
METAL DOWNSPOUT - BLACK
S-1
FIBER CEMENT 6" T+G VERTICAL SIDING - OLIVE GREEN
S-2
FIBER CEMENT 3" T+G VERTICAL SIDING - WHITE
GUTTER
S-3
BRICK VENEER SIDING - EARTH TONES
G-1
GUTTER - BLACK
S-4
2xl2 TRIM - WHITE
S-5
FIBER CEMENT PANEL - CHARCOAL
MECHANICAL
S-6
FIBER CEMENT PANEL - WHITE
M-1
MINI -SPLIT EXTERIOR UNIT
S-7
CEDAR T+G SIDING HORIZONTAL - NATURAL STAIN
M-2
VENT COVER -MATCH ADJACENT SIDING COLOR
S-8
6" FASCIA - CHARCOAL
S-9
CONCRETE
LIGHTING
S-10
PLASTER PLINTH
L-1
WALL SCONCE - BLACK
L-2
STEP LIGHT - BLACK
L-3
FLOOD LIGHT - BLACK
WEST ELEVATION
SCALE: 1 /4" = 1 '-0"
a
�0
0 2 4 8
1 /4" = 1 '-0"
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v I
tLU
v I
0
CD
N
Z0�
0
I- O
Z
O
O
W "'
J
w
a0-1
w
o�
w
0
�o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
22
Revision 2
04/03/23
ARevision
3
09/15/23
ARevision
4
02/05/24
ARevision
5
06/10/24
66
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ELEVATIONS
SCALE: AS NOTED
A301
ELEVATION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4. REF. FLOOR PLANS, A2 SERIES, FOR EXTERIOR DOOR SIZES.
5. WINDOWS MARKED "EG" ARE EGRESS WINDOWS AND SHALL COMPLY WITH THE
FOLLOWING PER IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
6. WINDOWS AND DOORS MARKED "SG" SHALL BE PROVIDED WITH SAFETY GLAZING
PER IRC R308.4.
7. WINDOWS SHALL BE ANDERSON 100 SERIES (OR APPROVED EQUAL).
8. ELEVATIONS ARE ORIENTED TOWARD PROJECT NORTH. SEE Al AND A2 SHEETS FOR
REFERENCE.
9. OVERHANGING EAVE ATTACHMENT AND FABRICATION BY OTHERS.
10. LINE OF SITE STAIRS (WITHIN).
211. DISTANCE FROM BUILDING TO PROPERTY LINE VARIES. SEE All FOR DETAILS..
12, GUARDRAIL PER 3/A5.4
13. GUTTER AND DOWNSPOUT NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
14. BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
15. BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
0
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17'-0" (71.85'±)
SECOND SUBFLOOR
8'-6" (63.354)
SLAB ON GRADE
U-0" (54.85'±)
AVERAGE GRADE
4-12" (53.85'±)
0
0
M
1'-0"
�0
00
�o
bD
MATERIAL NOTES
DOORS
SPECIALTY
D-1
FRONT DOOR- BLACK FIBERGLASS
SP-1
WOOD CANOPY - CHARCOAL
SP-2
BIORETENTION PLANTER - STEEL PLATE
D-2
GARAGE DOOR - BLACK FIBERGLASS
SP-3
BOLT -ON BALCONY - BLACK
D-3
SLIDER DOOR - BLACK FIBERGLASS
SP-4
5" PLASTER LINTEL PER 3/A5.2
ROOFING
WINDOWS
R-1
STANDING SEAM METAL ROOF - BLACK
W-1
FIBERGLASS WINDOWS - BLACK
R-2
HARDIE SOFFIT, LIGHT GRAY
DOWNSPOUT
SIDING
DS-1
METAL DOWNSPOUT - BLACK
S-1
FIBER CEMENT 6" T+G VERTICAL SIDING - OLIVE GREEN
S-2
FIBER CEMENT 3" T+G VERTICAL SIDING - WHITE
GUTTER
S-3
BRICK VENEER SIDING - EARTH TONES
G-1
GUTTER - BLACK
S-4
2xl2 TRIM - WHITE
S-5
FIBER CEMENT PANEL - CHARCOAL
MECHANICAL
S-6
FIBER CEMENT PANEL - WHITE
M-1
MINI -SPLIT EXTERIOR UNIT
S-7
CEDAR T+G SIDING HORIZONTAL - NATURAL STAIN
M-2
VENT COVER -MATCH ADJACENT SIDING COLOR
S-8
6" FASCIA - CHARCOAL
S-9
CONCRETE
LIGHTING
S-10
PLASTER PLINTH
L-1
WALL SCONCE - BLACK
L-2
STEP LIGHT - BLACK
L-3
FLOOD LIGHT - BLACK
N
EAST ELEVATION
SCALE: 1 /4" = 1 '-0"
0 2 4 8
1 /4" = 1 '-0"
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
U)
w
0
_CD
N
Z0�
0�
I- O
Z
O
O
W "'
J
w
a0-1
w
o�
w
0
�o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
22
Revision 2
04/03/23
ARevision
3
09/15/23
ARevision
4
02/05/24
ARevision
5
06/10/24
66
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ELEVATIONS
SCALE: AS NOTED
A302
ELEVATION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3. SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4. REF. FLOOR PLANS, A2 SERIES, FOR EXTERIOR DOOR SIZES.
5. WINDOWS MARKED "EG" ARE EGRESS WINDOWS AND SHALL COMPLY WITH THE
FOLLOWING PER IRC R310.
• MIN. 5.7 SF NET CLR OPENABLE AREA
• MIN. 24" NET CLR OPENABLE HEIGHT
• MIN. 20" NET CLR OPENABLE WIDTH
• MAX. 44" FINISHED SILL HEIGHT
• OPENABLE W/O KEYS OR SPECIAL TOOLS
6. WINDOWS AND DOORS MARKED "SG" SHALL BE PROVIDED WITH SAFETY GLAZING
PER IRC R308.4.
7. WINDOWS SHALL BE ANDERSON 100 SERIES (OR APPROVED EQUAL).
8. ELEVATIONS ARE ORIENTED TOWARD PROJECT NORTH. SEE Al AND A2 SHEETS FOR
REFERENCE.
9. OVERHANGING EAVE ATTACHMENT AND FABRICATION BY OTHERS.
10. LINE OF SITE STAIRS (WITHIN).
211. DISTANCE FROM BUILDING TO PROPERTY LINE VARIES. SEE All FOR DETAILS..
12, GUARDRAIL PER 3/A5.4
13. GUTTER AND DOWNSPOUT NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
14. BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. AO.5 FOR DTLS.
15. BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
0
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17'-0" (71.85'±)
SECOND SUBFLOOR
8'-6" (63.35'±)
SLAB ON GRADE
0'-0" (54.85'±)
AVERAGE GRADE
-0'-12"(53.85'±)
MATERIAL NOTES
DOORS
SPECIALTY
D-1
FRONT DOOR- BLACK FIBERGLASS
SP-1
WOOD CANOPY - CHARCOAL
SP-2
BIORETENTION PLANTER - STEEL PLATE
D-2
GARAGE DOOR - BLACK FIBERGLASS
SP-3
BOLT -ON BALCONY - BLACK
D-3
SLIDER DOOR - BLACK FIBERGLASS
SP-4
5" PLASTER LINTEL PER 3/A5.2
ROOFING
WINDOWS
R-1
STANDING SEAM METAL ROOF - BLACK
W-1
FIBERGLASS WINDOWS - BLACK
R-2
HARDIE SOFFIT, LIGHT GRAY
DOWNSPOUT
SIDING
DS-1
METAL DOWNSPOUT - BLACK
S-1
FIBER CEMENT 6" T+G VERTICAL SIDING - OLIVE GREEN
S-2
FIBER CEMENT 3" T+G VERTICAL SIDING - WHITE
GUTTER
S-3
BRICK VENEER SIDING - EARTH TONES
G-1
GUTTER - BLACK
S-4
2xl2 TRIM - WHITE
S-5
FIBER CEMENT PANEL - CHARCOAL
MECHANICAL
S-6
FIBER CEMENT PANEL - WHITE
M-1
MINI -SPLIT EXTERIOR UNIT
S-7
CEDAR T+G SIDING HORIZONTAL - NATURAL STAIN
M-2
VENT COVER -MATCH ADJACENT SIDING COLOR
S-8
6" FASCIA - CHARCOAL
S-9
CONCRETE
LIGHTING
S-10
PLASTER PLINTH
L-1
WALL SCONCE - BLACK
L-2
STEP LIGHT - BLACK
L-3
FLOOD LIGHT - BLACK
NORTH ELEVATION
SCALE: 1 /4" = 1 '-0"
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
0 2 4 8
1 /4" = 1 '-0"
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
v I
tUJI
v I
0
=O
N
ZO
0�
0
O
Z
O
O
W "'
J
w
a0-1
w
o�
w
0
�o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
22
Revision 2
04/03/23
ARevision
3
09/15/23
ARevision
4
02/05/24
ARevision
5
06/10/24
66
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
ELEVATIONS
SCALE: AS NOTED
A303
R-1: STANDING SEAM
METAL ROOF (BLACK)
D-3: SLIDER DOOR
(BLACK FIBERGLASS)
SP-3: BOLT -ON
BALCONY (BLACK)
S-5: FIBER CEMENT
PANEL (CHARCOAL)
SP-1: WOOD CANOPY
(CHARCOAL)
D-1: FRONT DOOR
(BLACK FIBERGLASS)
R-1: STANDING SEAM
METAL ROOF (BLACK)
S-1: FIBER CEMENT 3" T+G
VERTICAL SIDING (WHITE)
S-1: FIBER CEMENT 6" T+G
VERTICAL SIDING (OLIVE
GREEN)
W-1: FIBERGLASS
WINDOWS (BLACK)
SP-1: WOOD CANOPY
(CHARCOAL)
L-1: SCONCE
D-2: GARAGE DOOR
(BLACK)
WEST ELEVATION
SCALE: 1 /8" = 1
EAST E L EVAT I O N
SCALE: 1 /8" = 1
S-1: FIBER CEMENT 6" T+G
VERTICAL SIDING (OLIVE
GREEN)
D-3: SLIDER DOOR
(BLACK FIBERGLASS)
SP-3: BOLT -ON
BALCONY (BLACK)
S-3: BRICK VENEER
SIDING (EARTH TONES
W-1: FIBERGLASS
WINDOWS (BLACK)
S-1: FIBER CEMENT 6" T+G
VERTICAL SIDING (WHITE)
D-3: SLIDER DOOR
(BLACK FIBERGLASS)
SP-1: WOOD CANOPY
(CHARCOAL)
S-3: BRICK VENEER
SIDING (EARTH TONES)
SP-4: PLASTER LINTEL
S-10: PLASTER PLINTH
SOUTH ELEVATION
SCALE: 1 /8" = 1 '
NORTH E L EVAT I O N
SCALE: 1 /8" = 1
i
R-1: STANDING SEAM
METAL ROOF (BLACK)
S-1: FIBER CEMENT 3" T+G
VERTICAL SIDING (WHITE)
W-1: FIBERGLASS
WINDOWS (BLACK)
SP-1: WOOD CANOPY
(CHARCOAL)
M
- S-3 BRICKVENEER
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SIDING (EARTH TONES
M
M
M
M
M
C
R-1: STANDING SEAM
METAL ROOF (BLACK)
F
y
� J
_CD
N
ZCD
0�
o
W
�
�z
z
0
w
o
J
w
Qw
O
w a
0
M M
City of EDMONDS
Permit Set
M October 7, 2022
S-1: FIBER CEMENT 3" T+G
VERTICAL SIDING (WHITE)
1� Revision 1
2� Revision 2
ARevision 3
A4 Revision 4
A5 Revision 5
z Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
RENDERED
ELEVATIONS
SCALE: AS NOTED
A304
e
TOWNHOMES VIEWED FROM NORTHWEST
SCALE: NTS
TOWNHOMES VIEWED FROM NORTH
SCALE: NTS
�
1
1
CITIZEN
� I1E516N
M
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
UJI
M 0
=o
N
Z�
M �0�
0
�z
Z
0
M �o
Ww
J
U
o�
Oo
w
M �o
CM
M
r City of EDMONDS
Permit Set
October 7, 2022
` A Revision 1
f
` 22 Revision 2
f
` A Revision 3
f
A Revision 4
55 Revision 5
f 66 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
RENDERINGS
SCALE: AS NOTED
A305
e
TOWNHOMES VIEWED FROM NORTH
SCALE: NTS
TOWNHOMES VIEWED FROM MOTOR COURT
SCALE: NTS
4
CITIZEN
� I1E516N
M
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
UJI
M 0
` =
O
N
fl Z�
0�
0
In
z
Z
O
O
W
"'
J
U
o�
Oo
w
M �o
CM
M
r City of EDMONDS
Permit Set
October 7, 2022
` A Revision 1
f
` A� Revision 2
f
` ZL Revision 3
f
A Revision 4
55 Revision 5
f 66 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
r
RENDERINGS
SCALE: AS NOTED
A306
0
SECTION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2.
DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3.
SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4.
GUTTER PER PLAN.
5.
ROOF OVERFRAMING PER TRUSS MFR.
6.
PROVIDE (1) LAYER %" TYPE X GWB AT UNDERSIDE OF STAIRS.
7.
SEE 3/A5.3 & 4/A5.3 FOR STAIR AND RAILING DETAILS.
8.
CANOPY PER DETAIL 5/A5.3.
9.
PARTY WALLS SHALL EXTEND THROUGH ATTIC AND BE TIGHT TO
2
UNDERSIDE OF ROOF SHEATHING
10.
BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. A0.5
FOR DTLS.
11.
BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
12.
BIORETENTION PLANTER PER CIVIL. SHOWN FOR REF. ONLY.
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17'-0" (71.85'±)
SECOND SUBFLOOR JIIII
8'-6" (63.35'±)
SLAB ON GRADE
0'-0" (54.85'±)
AVERAGE GRADE JIIII
4-12" (53.85'±)
0
WALL ASSEMBLIES
WALL: TYP. EXTERIOR
17
W1 SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
Z" GWB
RESERVED
W2
A
WALL: 1-HR PARTY WALL
W3 REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUCTURAL
3 z" FIBERGLASS BATT
%" TYPE X GWB
WALL: TYP. INTERIOR
W4 %"GWB
FRAMING PER PLAN
2" GWB
`r
TRANSVERSE SECTION
SCALE: 1 /4" = 1 '-0"
FLOOR ASSEMBLIES
WALL: INSULATED INTERIOR
FLOOR: TYP. MASS TIMBER
W5
F1
%" GWB
MASS TIMBER SLAB PER STRUCTURAL
2x6 FRAMING PER PLAN
R-21 MIN. BATT INSULATION
%" GWB
FLOOR: INSULATED SLAB ON GRADE
F2
CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION UNDER
WALL: UNINSULATED EXTERIOR
ENTIRE SLAB
W6
4" COMPACTED GRAVEL
W1 ASSEMBLY, EXCEPT:
NO INSULATION
FLOOR: INSULATED MASS TIMBER
F3
WALL: FURRING WALL
MASS TIMBER SLAB PER STRUCTURAL
W7
R-30 MIN. RIGID INSULATION
2x FRAMING PER PLAN
6" XPS OR EQUAL
IF GWB
EXTERIOR SLAB ON GRADE
D1 CONCRETE SLAB PER STRUCTURAL
ROOF/CEILING ASSEMBLIES
ROOF: TYPICAL FRAMED
R1 STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
1 2 1 2
A4.2 T
A4.2 3 A4.3 4 A4.3 5
I I
CEILING, TYPICAL
C1 5 GWB
CEILING: GARAGE
C2 %" TYPE X GWB
CEILING: EXTERIOR SOFFIT
C3 4"FIBERCEMENTT+G
CEILING: DROPPED SOFFIT
C4 2x6 FRAMING
%" GWB
CITIZEN
ESIGH
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
_ I
,uUJI
_ I
D
0
o
N
Zo
eo
Z 0%
0
0
Z
O
O
W "'
J W
Q W
0ul
W
O a
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision
1
10/21/22
ARevision
2
04/03/23
ARevision
3
09/15/23
A4
Revision 4
02/05/24
Z&
Revision 5
06/10/24
6
Revision 6
08/22/24
FOR PLANNING DEPT USE ONLY
SECTIONS
AND ASSEMBLIES
SCALE: AS NOTED
1 /4" = 1 '-0"
A401
0
SECTION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2.
DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3.
SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4.
GUTTER PER PLAN.
5.
ROOF OVERFRAMING PER TRUSS MFR.
6.
PROVIDE (1) LAYER %" TYPE X GWB AT UNDERSIDE OF STAIRS.
7.
SEE 3/A5.3 & 4/A5.3 FOR STAIR AND RAILING DETAILS.
8.
CANOPY PER DETAIL 5/A5.3.
9.
PARTY WALLS SHALL EXTEND THROUGH ATTIC AND BE TIGHT TO
2
UNDERSIDE OF ROOF SHEATHING
10.
BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. A0.5
FOR DTLS.
11.
BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
12.
BIORETENTION PLANTER PER CIVIL. SHOWN FOR REF. ONLY.
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17-0" (71.85'±)
SECOND SUBFLOOR JIIII
8'-6" (63.35'±)
SLAB ON GRADE JIIII
0'-0" (54.85'±)
AVERAGE GRADE JIIII
4-12" (53.85'±)
a
WALL ASSEMBLIES
WALL: TYP. EXTERIOR
17
W1 SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
Z" GWB
RESERVED
W2
A
WALL: 1-HR PARTY WALL
W3 REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUCTURAL
3 z" FIBERGLASS BATT
%" TYPE X GWB
WALL: TYP. INTERIOR
W4 %"GWB
FRAMING PER PLAN
2" GWB
A2
LONGITUDINAL SECTION: UNIT A
SCALE: 1 /4" = 1 '-0"
WALL: INSULATED INTERIOR
W5 i GWB
2x6 FRAMING PER PLAN
R-21 MIN. BATT INSULATION
%" GWB
WALL: UNINSULATED EXTERIOR
W6 W1 ASSEMBLY, EXCEPT:
NO INSULATION
WALL: FURRING WALL
W7 2x FRAMING PER PLAN
IF GWB
FLOOR ASSEMBLIES
FLOOR: TYP. MASS TIMBER
F1 MASS TIMBER SLAB PER STRUCTURAL
FLOOR: INSULATED SLAB ON GRADE
F2 CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION UNDER
ENTIRE SLAB
4" COMPACTED GRAVEL
FLOOR: INSULATED MASS TIMBER
F3 MASS TIMBER SLAB PER STRUCTURAL
R-30 MIN. RIGID INSULATION
6" XPS OR EQUAL
EXTERIOR SLAB ON GRADE
D1 CONCRETE SLAB PER STRUCTURAL
ROOF/CEILING ASSEMBLIES
ROOF: TYPICAL FRAMED
R1 STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
CEILING, TYPICAL
C1 5 GWB
CEILING: GARAGE
C2 %" TYPE X GWB
CEILING: EXTERIOR SOFFIT
C3 4"FIBERCEMENTT+G
CEILING: DROPPED SOFFIT
C4 2x6 FRAMING
%" GWB
1
TB A4.1 A
LONGITUDINAL SECTION: UNIT B
SCALE: 1 /4" = 1 '-0"
CITIZEN
ESIGH
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Ul
W
0
D
0
o
N
Zo
eo
0%
0
O
Z
O
O
W "'
J W
Q W
0ul
W
O a
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision 1
ARevision 2
ARevision 3
A4 Revision 4
Z& Revision 5
6 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
SECTIONS
AND ASSEMBLIES
SCALE: AS NOTED
1 /4" = 1 '-0"
A402
0
SECTION NOTES
1❑ ALL DIMENSIONS ARE TO FACE OF FRAMING OR FOUNDATION (U.N.O.)
2.
DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS.
3.
SEE SHEET A0.1 FOR GENERAL ARCHITECTURAL NOTES.
4.
GUTTER PER PLAN.
5.
ROOF OVERFRAMING PER TRUSS MFR.
6.
PROVIDE (1) LAYER %" TYPE X GWB AT UNDERSIDE OF STAIRS.
7.
SEE 3/A5.3 & 4/A5.3 FOR STAIR AND RAILING DETAILS.
8.
CANOPY PER DETAIL 5/A5.3.
9.
PARTY WALLS SHALL EXTEND THROUGH ATTIC AND BE TIGHT TO
2
UNDERSIDE OF ROOF SHEATHING
10.
BALCONY/CANOPY NOT IN PLANE WITH PROPERTY LINE. REF. A0.5
FOR DTLS.
11.
BALCONY BY OTHERS UNDER DEFERRED SUBMITTAL.
12.
BIORETENTION PLANTER PER CIVIL. SHOWN FOR REF. ONLY.
HEIGHT LIMIT
29'-0"" (83.85'±)
TOP OF ROOF
29'-0" (83.85'±)
THIRD SUBFLOOR
17'-0" (71.85'±)
SECOND SUBFLOOR JIIII
8'-6" (63.35'±)
SLAB ON GRADE JIIII
0'-0" (54.85'±)
AVERAGE GRADE JIIII
4-12" (53.85'±) IV
WALL ASSEMBLIES
WALL: TYP. EXTERIOR
17
W1 SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
Z" GWB
RESERVED
W2
A
WALL: 1-HR PARTY WALL
W3 REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUCTURAL
3 z" FIBERGLASS BATT
%" TYPE X GWB
WALL: TYP. INTERIOR
W4 %"GWB
FRAMING PER PLAN
2" GWB
1
TB A4.1
1
LONGITUDINAL SECTION: UNIT 3
SCALE: 1 /4" = 1 '-0"
WALL: INSULATED INTERIOR
W5 i GWB
2x6 FRAMING PER PLAN
R-21 MIN. BATT INSULATION
%" GWB
WALL: UNINSULATED EXTERIOR
W6 W1 ASSEMBLY, EXCEPT:
NO INSULATION
WALL: FURRING WALL
W7 2x FRAMING PER PLAN
IF GWB
FLOOR ASSEMBLIES
FLOOR: TYP. MASS TIMBER
F1 MASS TIMBER SLAB PER STRUCTURAL
FLOOR: INSULATED SLAB ON GRADE
F2 CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION UNDER
ENTIRE SLAB
4" COMPACTED GRAVEL
FLOOR: INSULATED MASS TIMBER
F3 MASS TIMBER SLAB PER STRUCTURAL
R-30 MIN. RIGID INSULATION
6" XPS OR EQUAL
EXTERIOR SLAB ON GRADE
D1 CONCRETE SLAB PER STRUCTURAL
R
T I o
ROOF/CEILING ASSEMBLIES
ROOF: TYPICAL FRAMED
R1 STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
1
A4.1
LONGITUDINAL SECTION: UNIT
SCALE: 1 /4" = 1 '-0"
CEILING, TYPICAL
C1 5,GWB
CEILING: GARAGE
C2 %" TYPE X GWB
CEILING: EXTERIOR SOFFIT
C3 4"FIBERCEMENTT+G
CEILING: DROPPED SOFFIT
C4 2x6 FRAMING
%" GWB
T
CITIZEN
ESIGH
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Zo
eo
0%
0
0
Z
O
O
W "'
J W
Q W
0ul
W
O a
� o
CM M
City of EDMONDS
Permit Set
October 7, 2022
ARevision 1
ARevision 2
ARevision 3
A4 Revision 4
Z& Revision 5
6 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
SECTIONS
AND ASSEMBLIES
SCALE: AS NOTED
1 /4" = 1 '-0"
A403
ROOF (R1)
STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
TYPICAL EXTERIOR WALL (W1)
SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
%" GWB
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
(bA52
r �
DA53
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
I
l I
9
A5.3
r
TYP. EXTERIOR WALL
SCALE: 1 /2" = 1 '-0"
INSULATED SLAB ON GRADE (F2)
CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION
UNDER ENTIRE SLAB
4" COMPACTED GRAVEL
ROOF (R1)
STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
TYPICAL EXTERIOR WALL (W1)
SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
%" GWB
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
TYPICAL EXTERIOR WALL (W1)
SIDING PER ELEVATION
INFILTRATION BARRIER (TYVEK OR EQUIV.)
PLYWOOD SHEATHING PER STRUCTURAL
2x FRAMING PER STRUCTURAL
R-21 MIN. BATT INSULATION
%" GWB
INSULATED SLAB ON GRADE (F2)
CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION
UNDER ENTIRE SLAB
4" COMPACTED GRAVEL
J
NOTE:
SIDING MATERIALS AND TRIM
OFFSET FOR CLARITY. DO NOT
CROSS THE PROPERTY LINE
WITHOUT APPROVAL OF THE
CITY OF EDMONDS.
TYP. EXTERIOR WALL
SCALE: 1 /2" = 1 '-0"
0
—MO
ROOF (R1)
STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
8" GWB
PAINT PER OWNER
7
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
TYPICAL FLOOR (F1)
7 MASS TIMBER SLAB PER
A5.2 STRUCTURAL
1
JI
8
4A5.2
r 1
JI
=ENi►
INSULATED SLAB ON GRADE (F2)
CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION
UNDER ENTIRE SLAB
4" COMPACTED GRAVEL
ROOF (R1)
STANDING SEAM METAL ROOFING PER OWNER
30# FELT UNDERLAYMENT
ICE + WATER SHIELD @ EAVES, HALF -LAPPED
EXTENDS 24" ABOVE WALL LINE
SHEATHING PER STRUCTURAL
OVERFRAMING WHERE OCCURS
TRUSSES PER STRUCTURAL
1" MIN. AIR GAP
R-49 MIN. BATT INSULATION
%" GWB
PAINT PER OWNER
7
CITIZEN
DESIGN
�� II II II II II
II II II II II II
�� II II II II II
TYPICAL PARTY WALL (W3)
REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUC'L
3%" FIBERGLASS BATT
%" TYPE X GWB
11
TYP.
A5.2
TYPICAL PARTY WALL (W3)
REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUC'L
3%" FIBERGLASS BATT
%" TYPE X GWB
\\ \\ \\ \\ \\ \\ \\ \\
/\ //
NOTE:
ALL ASSEMBLIES
TYP. OF BOTH SIDES
PARTY WALL AT ROOF INTERSECTION
SCALE: 1 /2" = 1 '-0"
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
TYPICAL PARTY WALL (W3)
REFERENCE ASSEMBLY: GA FILE NO. WP 5513 (STC 45)
%" TYPE X GWB
SHEATHING PER STRUCTURAL (WHERE OCCURS)
2x4 STAGGERED FRAMING ON 2x6 PLATES PER STRUC'L
3%" FIBERGLASS BATT
%" TYPE X GWB
TYPICAL FLOOR (F1)
MASS TIMBER SLAB PER
STRUCTURAL
`
f
M
M �
w
M �
M 0
` = O
N
fl Z00
0o
`
f
0 to
O
Z
O
O
w
UJI
TYPICAL FLOOR (F1)
11 MASS TIMBER SLAB PER
TYP' A5,2 STRUCTURAL
` w
f Lu
r
w
,....
o
*Am I mooCM
�
M
A
Cit of EDMONDS
r y
I
Permit Set
'
October 7, 2022
EA]
NOTE:
ALL ASSEMBLIES
TYP. OF BOTH SIDES
TYP. PARTY WALL
SCALE: 1 /2" = 1 '-0"
INSULATED SLAB ON GRADE (F2)
CONCRETE SLAB PER STRUCTURAL
6 MIL MIN. VAPOR BARRIER
R-10 (2" XPS MIN.) RIGID INSULATION
UNDER ENTIRE SLAB
4" COMPACTED GRAVEL
` A Revision 1
f
` 22 Revision 2
f
` Revision 3
f
Revision 4
Revision 5
f 6� Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
f
WALL SECTIONS
SCALE: AS NOTED
A501
INFILTRATION BARRIER
SIDING PER ELEVATION
FLEXIBLE FLASHING
METAL FLASHING
TYPICAL WINDOW HEADER
SCALE: 3" = V-0"
FLEXIBLE FLASHING
INFILTRATION BARRIER
SIDING PER ELEVATION
IJ
TYPICAL WINDOW SILL
SCALE: 3" = V-0"
CONCRETE FLOOR SLAB
PER STRUCTURAL
6 MIL (MIN) VAPOR
BARRIER
2" FOAM INSULATION
4" COMPACTED GRAVEL
CONCRETE FOUNDATION
WALL PER STRUCTURAL
SLAB AT GARAGE DOOR
SCALE: 3" = V-0"
R-10 MIN. RIGID
INSULATION
HEADER PER
STRUCTURAL
%" GWB
BACKER ROD AND
SEALANT
WINDOW PER PLAN
WINDOW PER PLAN
SEALANT
FLEXIBLE FLASHING
WOOD SILL
z" GWB
"""""ETE COLD JOINT
ETE DRIVEWAY
/IL
WINDOW PER PLAN
FLEXIBLE FLASHING
INFILTRATION BARRIER
SIDING PER ELEVATION
FLEXIBLE FLASHING
%" GWB
WINDOWSILL
TYPICAL WINDOW JAMB.
SCALE: 3" = V-0"
HARDIE OUTSIDE CORNER
SCALE: 3" = V-0"
PLYWOOD SHEATHING
SIDING PER ELEVATION
GROUT PER MFR.
CEMENT BACKER BOARD
INFILTRATION BARRIER
SHEET METAL DRIP
EDGE FLASHING
GARAG E CU RB
SCALE: 3" = V-0"
�i11:L1�
BRICK VENEER
PER ELE
INFILTRATION B,
METAL FLi
WRAP LATH AND
PLASTER AROUND
LEDGER
2x4 P.T. LEDGER w/ TOP
EDGE RIPPED TO SLOPE
PLASTER PER ELE
WIRE MES
CEMENT BACKER
BRICK TO PLASTER TRANSITION
SCALE: 3" = F-0"
HARDIE SIDING PER ELEVATION
INFILTRATION BARRIER
HARDIE TRIM PER ELEVATION
BACKER ROD AND SEALANT
CEMENT BACKER BOARD
BRICK VENEER SIDING
PER ELEVATION
SF
PANEL JOINT PER
6" MPP PER
PROVIDES 1-1-1I
PER IBC 2:
TABLE 601
BRICK TO HARDIE TRANSITION
SCALE: 3" = F-0"
H SIDE
FIRE RATING AT FLOOR/PARTY WALL
SCALE: 3" = 1 '-0"
SWINGING DOOR SILL @ CONC.
SCALE: 3" = V-0"
WHITE WOOD TRIM
FINISH PER OWNER
ch Z \
J U
mw
LUL
wn
Ln w
<a
TYP. SIDING BASE
SCALE: 3" = V-0"
J
-IING
JOINT
PLYWOOD SHEATHING
SIDING PER ELEVATION
GROUT PER MFR.
CEMENT BACKER BOARD
INFILTRATION BARRIER
SHEET METAL DRIP
EDGE FLASHING
1/2" MIN.
z
co
SLOPE
2%
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
f
f
f
W
`
f
M 0
` =
o
N
fl
Z00
00
O�
0
to
z
Z
O
W
"'
J
w
aw
M oU')
Oo
w
M �o
M
M
r City of EDMONDS
Permit Set
October 7, 2022
Revision 1
f
` 22 Revision 2
f
` A Revision 3
f
A Revision 4
Revision 5
f 66 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
f
DETAILS
SCALE: AS NOTED
A502
SIDING PER ELEVATION
SIDING PER ELEVATION
RUN INFILTRATION BARRIER
CONTINUOUS BEHIND BRACKET
FLEXIBLE FLASHING
BRACKET, CLEVIS AND
CONNECTION PER 8/S3.1
METAL FLASHING
METAL ROOF
BRACKET, CLEVIS AND
CONNECTION PER 8/S3.1
METAL FLASHING
GUTTER + DOWNSPOUT
PER PLAN
1 x FASCIA. PAINT TO
MATCH SIDING
BEAM PER STRUCTURAL
T&G HARDIE SOFFIT
2x SOFFIT FURRING
FRAMING PER STRUC'L
RIPPED TO SLOPE
ENTRY CANOPY
SCALE: 1 " = 1 '-0"
RAISED S
GRADE W/
AND ENTR`
_OOR
CONCRETE W/
STRU
ENTRY WALKWAY
SCALE: I" = 1 '-0"
NOTE:
HANDRAIL ENDS SHALL RETURN TO
THE WALL OR TERMINATE IN NEWEL
POSTS OR SAFETY TERMINALS.
2 z"0 x%" S.S. PLATE
CONNECT WITH 2 BOLTS
AND CINCH ANCHORS PER
PLATE FASTENED TO
WALL, MAX 3'-0" O.C. (TYP.)
TYP. HANDRAIL
�.3SCALE: I" = 1 '-0"
4'-0" MIN. EACH SIDE
FIRE -RETARDANT TREATED
SHEATHING PER STRUCTURAL
STANDING SEAM METAL ROOFING
30# FELT UNDERLAYMENT
II ��
II ��
II ��
i
(1) LAYER %" GWB J
ASSEMBLY W3 PER SECTION
I
ASSEMBLY R1 PER SECTION
(2) LAYERS TYPE X GWB
CONTINUOUS TO UNDERSIDE
OF ROOF SHEATHING
BETWEEN TWO INTERIOR UNITS
TYP. PARTY WALL TERMINATION
SCALE: 3/4"=1 '-0"
4"0 STEEL DOWNSPOUT
CLEANOUT
FINISHED GRADE
4"0 TO 6"0 ADAPTER
6"0 CONC% BEND
TIGHTLINE TO BMP PER A1.4
- t7� - — - N
SECTION A SECTION B
FINISHED FLOOR
ROOF PENETRATION
PER 8/A5.4
ROUTE VENTS AND DUCTS TO
AVOID PENETRATIONS
THROUGH ROOF WITHIN 4'-0"
OF PARTY WALL
BUILDING WALL
STORM DRAIN
WYE
TYP. DOWNSPOUT CONNECTION
SCALE: I" = 1 '-0"
TYP. STAIR
SCALE: 1 " = 1 '-0"
11
4'-0" MIN. EACH SIDE
X�
TRUSSES AND CONNECTION
PER STRUCTURAL
(2) LAYERS TYPE X GWB
CONTINUOUS TO UNDERSIDE
OF ROOF SHEATHING
FIRE -RETARDANT TREATED
SHEATHING PER STRUC.
ASSEMBLY R1 PER SECTION
(1) LAYER %" GWB
ASSEMBLY W3 PER SECTION
BETWEEN AN INTERIOR UNIT AND AN EXTERIOR UNIT
NOTE:
EXTERIOR WALL NOT
SHOWN FOR CLARITY
EXTERIOR FLOOR SLAB
(WHERE OCCURS)
GRAVEL BACKFILL FOR DRAINS PER
WSDOT 9-03.12(4)
WRAP WITH FILTER FABRIC.
FABRIC SHALL BE SUPAC SNP
OR APPROVED EQUAL
4" OR 6" SDR 35 PVC PERF. PIPE.
TIGHTLINE TO SD CONVEYANCE
SYSTEM PER A1.4
EXPANSION JOINT
6" MIN.
,2 TYP. FOOTING DRAIN
SCALE: 1 " = 1 '-0"
INTERIOR SLAB F3
(WHERE OCCURS)
FOOTING AND STEM
WALL PER STRUC'L
F
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
f
f
f
f
W
`
f
M O
` =
o
N
fl Z00
ao
`
f
O0
O
Z
O
O
W
"'
J
w
aw
M oU')
C)
w
o
�
CM
o
M
r City of EDMONDS
Permit Set
October 7, 2022
`
Revision 1
f
` 22
Revision 2
f
` A
Revision 3
f
Revision 4
f A
Revision 5
f / 6 \
RaviSinn A
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
DETAILS
SCALE: AS NOTED
A503
Al
NOTE:
TIEBACKS AND WALL CONNECTION
SIMILAR TO 5/A5.3
METAL RAIL PER MFR
METAL INTERMEDIATE
MEMBER PER MFR
METAL GRATE
DECKING PER MFR
BASE PLATE
CONNECTION PER MFR
STEEL CHANNEL
---
— — — —
-------
FRAME PER MFR
L
STANDOFF TO PROVIDE DECKING
HARDIE SOFFIT
SLOPE (WHERE OCCURS)
(WHERE OCCURS)
WEATHER -RESISTANT
WEATHER -RESISTANT
CORRUGATED METAL DECKING
HAT CHANNEL. MATCH
PER MFR (WHERE OCCURS)
SPACER DEPTH.
(WHERE OCCURS)
TYP. BALCONY AND GUARDRAIL
SCALE: 1 " = F-0"
w.v 1\ YrMI IV= W 111\ t1 Mr.\ 1
0
MAINTAIN 1" MIN. CLEAR
AIRSPACE ABOVE
INSULATION FOR
CROSS -VENTILATION
2x BLOCKING PER STRUCT
COR-A-VENT S400 OR
APPROVED EQUAL.
FLEXIBLE FLASHING
METAL FLASHING
GUTTER + DOWNSPOUT
PER PLAN
1 x FASCIA. PAINT TO
MATCH SIDING
TYP. EAVE AND GUTTER
SCALE: 1 " = F-0"
EXHAUST VENT
SCALE: I" = 1 '-0"
TURBINE VENTILATOR
SCALE: I" = 1 '-0"
EXHAUST VENT
FLEXIBLE FLASHING
WRAP WEATHER BARRIER UP
SIDE OF EXHAUST VENT
METAL COLLAR
TURBINE VENT AND
BASE PER MFR
FLEXIBLE FLASHING
WRAP WEATHER BARRIER UP
SIDE OF VENTILATOR
METAL COLLAR
CITIZEN
DESIGN
RES U B
Aug 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
f
f
W
`
f
M O
` =
O
N
fl
Z
00
0�
OIn
z
Z
O
O
W
"'
J
w
aw
M o�
o0
w
M �o
CM
M
r City of EDMONDS
Permit Set
October 7, 2022
` A Revision 1
f
` 22 Revision 2
f
` A Revision 3
f
A Revision 4
55 Revision 5
f 66 Revision 6
10/21 /22
04/03/23
09/15/23
02/05/24
06/10/24
08/22/24
FOR PLANNING DEPT USE ONLY
DETAILS
SCALE: AS NOTED
A504