BLD2025-0172_Manufacturer_Specifications_and_Installation_Instructions_2.4.2025_1.57.11_PM_4745413iaw UPFLOW/HORIZONTAL TWO -STAGE, VARIABLE SPEED Shtw(ard GAS -FIRED FURNACE HEATING & AIR C O N D I T I O N I N G 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o a o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O H0IE0��� g000�00��0DODO K0000000000 o000000000 fl K0000000000. o 0 0000000000DODO K0�0�0�00� li0000 �0��0H 0�00 0 0 0 0 0 0 0 � � 0 0 0 0 � 0 0 000� FREEDOM 80vs MODELS AUD2B060A9V3VB AUD2B080A9V3VB AUD2C080A9V4VB AU D2C080B9V4VA AUD2B100A9V3VB AUD2C100A9V5VB AU D2C100B9V5VA AUD2D120A9V5VB AUD2D120B9V5VB AUD2D140A9V5VB 0 2011 American Standard Heating & Air Conditioning PUB. NO. 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning • Upflow/Horizontal and • Power supply 115/1/60 • 2-stage gas valve • 2-speed venter • Variable speed blower motor • Silicon Nitride hot surface igniter with adaptive heat up • Integrated solid state control • Attractive color accents FREEDOM 80vs STANDARD EQUIPMENT • Alternate bottom/left/right return air • Slide out blower assembly • Hinged blower door • Perfect fit door catches • Insulated blower door • Gasketed blower door • Internal filter rack • Standard filter sizes • Two-tone color • Heavy gauge aluminized steel heat • Direct drive, variable speed motor exchanger • Integrated solid state control with • Multi -port In -shot burners self -diagnostics • Complete front service access • Common vent capability • Cleanable framed filters • Optional L. P. conversion kit • Left/right gas connection • Accessory hook-up capability • Selectable cooling fan off delay eliminates need for BAY24XO45 time delay kit • Enhanced cooling control FREEDOM 80vs OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling........................................................................................ TAYSTAT241 [ ] Thermostat, Mechanical Heating Only With Fan Switch............................................................................................. BAYSTAT303 [ ] Thermostat, Mechanical Heating Only....................................................................................................................... BAYSTAT388 [ l Thermostat, Heating/Cooling Single Stage (Mounts Horizontally).................................................................................AY28X092 [ ] Thermostat, Electronic Non -programmable 1-Stage Heating/1-Stage Cooling.......................................................... BAYSTAT370 [ ] Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling......................................................... BAYSTAT340 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically).................................................................................. BAYSTAT305 [ ] Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling............................................................... TAYSTAT302C [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling............................................................... TAYSTAT300C [ ] Propane Conversion Kit........................................................................................................................................... BAYLPKT210A [ l Electronic Air Filter, "Perfect Fit' High Efficiency (17-1/2" Wide Gas Furnace)........................................................ TFM175A9FR0 [ ] Electronic Air Filter, "Perfect Fit' High Efficiency (21" Wide Gas Furnace).............................................................. TFM210A9FR0 [ ] Electronic Air Filter, "Perfect Fit' High Efficiency (24-1/2" Wide Gas Furnace)........................................................TFM245A9FR0 [ ] Electronic Air Filter, "Perfect Fit' Standard Efficiency (17-1/2" Wide Gas Furnace) .................................................. TFP175A9FR0 [ ] Electronic Air Filter, "Perfect Fit' Standard Efficiency (21" Wide Gas Furnace)........................................................ TFP210A9FR0 [ ] Electronic Air Filter, "Perfect Fit' Standard Efficiency (24-1/2" Wide Gas Furnace)..................................................TFP245A9FR0 [ ] Coil Enclosure (17-1/2" Wide Cabinets)............................................................................................................ BAYCLE1 7A1 722A [ ] Coil Enclosure (21" Wide Cabinets)..................................................................................................................BAYCLE21A2130A [ l Coil Enclosure (24-1/2" Wide Cabinets)............................................................................................................ BAYCLE24A2430A [ l SideFilter Rack.......................................................................................................................................................... BAYFLTR200 [ l High Altitude Switch.................................................................................................................................................... BAYHALT249 [ l Masonry Chimney Vent Kit (Upflow models only).................................................................................................... BAYVENT800B [ ] Filter Rack Kit O.................................................................................................................................................... BAYRACK960A [ l O Available for models with 1800 CFM or greater which require an additional side return. FEATURES NATURAL GAS MODELS — Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American Na- tional Standards Institute standards. SAFE OPERATION —The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual sole- noid combination gas valve and regulator provide extra safety. QUICK HEATING — Durable, cycle tested, heavy gauge alu- minized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS — Multi -port In -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL — Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self -diagnostics for ease of service. Also contains connection points for E.A.C./ humidifier. AIR DELIVERY —The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING — Heavy gauge steel and "wrap -around" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION — The Freedom 80vs High Efficiency Gas Furnaces employ a Hot Surface Igni- tion system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning AUD-R9V PRODUCT SPECIFICATIONSO MODEL AUD2B060A9V3VB AUD2B080A9V3VB AUD2C080A9V4VB TYPE Upflow/ Horizontal Upflow/ Horizontal Upflow/ Horizontal RATINGS 1st Stage Input BTUH 39,000 52,000 52,000 1st Stage Capacity BTUH (ICS) O 31,200 41,600 41,600 2nd Stage Input BTUH 60,000 80,000 80,000 2nd Stage Capacity BTUH (ICS) ® 48,000 64,000 64,000 Temp. rise (Min. -Max.) IF. 30 - 60 30 - 60 30 - 60 BLOWER DRIVE Direct Direct Direct Diameter - Width (In.) 10 x 7 10 x 7 10 1000 No. Used 1 1 1 Speeds (No.) Variable Variable Variable CFM vs. in. w.g. See AirflowTable See Airflow Table See Airflow Table Motor HP 1/2 1/2 3/4 R.P.M. Variable Variable Variable Volts / Ph/Hz 115/1/60 115/1/60 115/1/60 COMBUSTION FAN -Type Centrifugal Centrifugal Centrifugal Drive - No. Speeds Direct - 2 Direct - 2 Direct - 2 Motor HP - RPM 1/50 - 3000 1/50 - 3000 1/50 - 3000 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 FLA 0.7 0.7 0.7 FILTER — Furnished? Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 -17x25 -1 in. 1 -17x25 -1 in. 1 - 20x25 - 1 in. VENT — Size (In.) 4 Round 4 Round 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Type 1 Alum. Steel -Type 1 Alum. Steel -Type 1 -Unfired Gauge (Fired) 20 20 20 ORIFICES — Main Nat. Gas. Oty. — Drill Size 3 — 45 4 — 45 4 — 45 L. R Gas Oty. — Drill Size 3 — 56 4 — 56 4 — 56 GAS VALVE Redundant - Two Stage Redundant - Two Stage Redundant -Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS —Type Multi -port In -shot Multi -port In -shot Multi -port In -shot Number 3 4 4 POWER CONN. —V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 Ampacity (In Amps) 10.5 10.5 12.9 Max. Overcurrent Protection (Amps) 15 15 20 PIPE CONN. SIZE (In.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Crated (In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 WEIGHT Shipping (Lbs.)/Net (Lbs.) 136 / 126 142 / 132 166 / 155 O Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 ® For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S. government standard tests. ® The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 3 PRODUCT DATA American Standard Heating & Air Conditioning AUD-R9V PRODUCT SPECIFICATIONSO MODEL AUD2C080B9V4VA © AUD2B100A9V3VB AUD2C100A9V5VB TYPE Upflow/ Horizontal Upflow/ Horizontal Upflow/ Horizontal RATINGS U 1st Stage Input BTUH 52,000 65,000 65,000 1st Stage Capacity BTUH (I CS) ® 41,600 52,000 52,000 2nd Stage Input BTUH 80,000 100,000 100,000 2nd Stage Capacity BTUH (ICS) ® 64,000 80,000 79,000 Temp. rise (Min. -Max.) °F. 30 - 60 40 - 70 35 - 65 BLOWER DRIVE Direct Direct Direct Diameter - Width (In.) 10 x 10 10 x 7 10 x 10 No. Used 1 1 1 Speeds (No.) Variable Variable Variable CFM vs. in. w.g. See Airflow Table See Airflow Table See AirflowTable Motor HP 3/4 1/2 1 R.P.M. Variable Variable Variable Volts / Ph / Hz 115/1/60 115/1/60 115/1/60 COMBUSTION FAN -Type Centrifugal Centrifugal Centrifugal Drive - No. Speeds Direct - 2 Direct - 2 Direct - 2 Motor HP - RPM 1/50 - 3000 1/50 - 3000 1/50 - 3000 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 FLA 0.7 0.87 0.87 FILTER — Furnished? Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 20x25 -1 in. 1 -17x25 -1 in. 1 - 20x25 -1 in. VENT — Size (In.) 4 Round 4 Round 4 Round HEAT EXCHANGER Type -Fired Alum. Steel - Type 1 Alum. Steel - Type 1 Alum. Steel - Type 1 -Unfired Gauge (Fired) 20 20 20 ORIFICES — Main Nat. Gas. Oty. — Drill Size 4 — 45 5 — 45 5 — 45 L. P. Gas Oty. — Drill Size 4 — 56 5 — 56 5 — 56 GAS VALVE Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS —Type Multi -port In -shot Multi -port In -shot Multi -port In -shot Number 4 5 5 POWER CONN. —V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 Ampacity (In Amps) 12.9 10.8 14.9 Max. Overcurrent Protection (Amps) 20 15 20 PIPE CONN. SIZE (In.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Crated (In.) 41-3/4 x 23 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 WEIGHT Shipping (Lbs.)/Net (Lbs.) 166 / 155 142 / 132 166 / 155 O Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 ® For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S. government standard tests. ® The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. © Model uses high efficiency blower. 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning AUD-R9V PRODUCT SPECIFICATIONSO MODEL AUD2C100B9V5VA © AUD2D120A9V5VB AUD2D120B9V5VB © AUD2D140A9V5VB TYPE Upflow/ Horizontal Upflow/ Horizontal Upflow/ Horizontal Upflow/ Horizontal RATINGS 1st Stage Input BTUH 65,000 78,000 78,000 91,000 1st Stage Capacity BTUH (ICS) ® 52,000 62,400 62,400 72,800 2nd Stage Input BTUH 100,000 120,000 120,000 140,000 2nd Stage Capacity BTUH (ICS) ® 79,000 97,000 97,000 111,000 Temp. rise (Min. -Max.) °F. 35 - 65 35 - 65 35 - 65 40 - 70 BLOWER DRIVE Direct Direct Direct Direct Diameter - Width (In.) 10 x 10 10 x 10 10 x 10 10 x 10 No. Used 1 1 1 1 Speeds (No.) Variable Variable Variable Variable CFM vs. in. w.g. See Airflow Table See Airflow Table See Airflow Table See Airflow Table Motor HP 1 1 1 1 R.P.M. Variable Variable Variable Variable Volts / Ph / Hz 115/1 /60 115/1 /60 115/1 /60 115/1 /60 COMBUSTION FAN -Type Centrifugal Centrifugal Centrifugal Centrifugal Drive - No. Speeds Direct - 2 Direct - 2 Direct - 2 Direct - 2 Motor HP - RPM 1/50 - 3000 1/50 - 3000 1/50 - 3000 1/50 - 3000 Volts/Ph/Hz 115/1 /60 115/1 /60 115/1 /60 115/1 /60 FLA 0.87 1.14 1.14 1.16 FILTER — Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel. (No.-Size-Thk.) 1 - 20x25 -1 in. 1 - 2425 -1 in. 1 - 2425 -1 in. 1 - 2425 -1 in. VENT — Size (In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type -Fired Alum. Steel -Type 1 Alum. Steel -Type 1 Alum. Steel -Type 1 Alum. Steel -Type 1 -Unfired Gauge (Fired) 20 20 20 20 ORIFICES — Main Nat. Gas. Qty. — Drill Size 5 — 45 6 — 45 6 — 45 7 — 45 L. P. Gas Qty. — Drill Size 5 — 56 6 — 56 6 — 56 7 — 56 GAS VALVE Redundant -Two Stage Redundant -Two Stage Redundant -Two Stage Redundant -Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS —Type Multi -port In -shot Multi -port In -shot Multi -port In -shot Multi -port In -shot Number 5 6 6 7 POWER CONN.—V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity (In Amps) 14.9 15.3 15.3 15.3 Max. Overcurrent Protection (Amps) 20 20 20 20 PIPE CONN. SIZE (In.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated (In.) 41-3/4 x 23 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 WEIGHT Shipping (Lbs.)/Net (Lbs.) 166 / 155 193 / 181 193 / 181 197 / 185 O Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 ® For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S. government standard tests. ® The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. © Model uses high efficiency blower. 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 5 PRODUCT DATA American Standard Heating & Air Conditioning *UD2BO6OA9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP. RISE 49 48 47 48 48 WATTS 65 95 125 160 200 CFM 663 694 684 681 686 HEATING 1ST MEDIUM " ON OFF TEMP. RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP. RISE 55 54 54 53 53 WATTS 110 150 185 240 280 CFM 907 919 942 958 959 HEATING 2ND MEDIUM " ON OFF TEMP. RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP. RISE 43 42 41 41 41 WATTS 190 260 325 365 415 *UD2BO6OA9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW ON ON OFF ON CFM 499 537 520 520 500 (350 CFM/TON) WATTS 50 80 110 145 175 NORMAL ON ON OFF OFF CFM 605 610 610 597 593 1.5 (400 CFM/ TON) WATTS 60 80 120 155 180 HIGH ON ON ON OFF CFM 649 681 665 665 672 (450 CFM/TON) WATTS 75 110 145 180 220 LOW OFF ON OFF ON CFM 680 722 680 696 696 (350 CFM/TON) WATTS 80 125 150 190 225 NORMAL OFF ON OFF OFF CFM 798 804 809 823 818 2 (400 CFM/TON) WATTS 105 145 170 235 280 HIGH OFF ON ON OFF CFM 884 896 924 931 931 (450 CFM/TON) WATTS 145 180 240 280 330 LOW ON OFF OFF ON CFM 858 863 882 894 895 (350 CFM/TON) WATTS 125 175 220 275 320 NORMAL ON OFF OFF OFF CFM 984 1017 1038 1017 1017 2.5 (400 CFM/TON) WATTS 170 225 295 330 375 HIGH ON OFF ON OFF CFM 1125 1138 1150 1161 1161 (450 CFM/TON) WATTS 245 315 370 435 475 LOW OFF OFF OFF ON CFM 1035 1056 1076 1076 1076 (350 CFM/TON) WATTS 205 265 330 370 430 NORMAL** OFF OFF OFF OFF CFM 1208 1247 1268 1278 1200 3 ,. (400 CFM/TON) WATTS 300 360 440 485 490 HIGH OFF OFF ON OFF CFM 1380 1410 1402 1350 1235 (450 CFM/TON) WATTS 440 500 550 550 525 NOTES: 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning *UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 790 765 750 730 LOW ON ON TEMP. RISE 48 49 50 52 53 WATTS 100 135 155 200 230 CFM 910 890 875 860 820 HEATING 1ST MEDIUM " ON OFF TEMP. RISE 43 44 44 45 47 STAGE WATTS 130 170 210 240 280 CFM 1060 1020 1010 1010 1000 HIGH OFF OFF TEMP. RISE 37 38 39 39 39 WATTS 188 220 265 310 350 CFM 1110 1090 1090 1080 1065 LOW ON ON TEMP. RISE 54 55 55 55 56 WATTS 210 260 310 350 400 MEDIUM " ON OFF CFM TEMP. RISE 1245 48 1240 48 1240 48 1230 48 1215 49 HEATING 2ND STAGE WATTS 300 355 410 460 500 CFM 1415 1400 1400 1375 1320 HIGH OFF OFF TEMP. RISE 42 42 42 43 45 WATTS 1 410 1 470 1 530 1 580 1 590 *UD2B080A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW OFF ON OFF ON CFM 880 875 860 845 840 (350 CFM/TON) WATTS 120 155 190 225 245 NORMAL OFF ON OFF OFF CFM 1020 1000 990 980 960 2.5 (400 CFM/TON) WATTS 170 205 240 280 320 HIGH OFF ON ON OFF CFM 1110 110 1110 1100 1100 (450 CFM/TON) WATTS 210 260 320 350 385 LOW ON OFF OFF ON CFM 1040 1010 1000 1000 990 (350 CFM/TON) WATTS 190 220 260 310 340 NORMAL ON OFF OFF OFF CFM 1200 1200 1190 1190 1175 3.0 (400 CFM/TON) WATTS 250 320 370 415 450 HIGH ON OFF ON OFF CFM 1340 1340 1330 1320 1300 (450 CFM/TON) WATTS 355 425 475 530 570 LOW OFF OFF OFF ON CFM 1215 1210 1210 1200 1185 (350 CFM/TON) WATTS 265 330 375 430 465 NORMAL** OFF OFF OFF OFF CFM 1430 1415 1410 1385 1330 3.5 — (400 CFM/TON) WATTS 415 457 520 575 580 HIGH OFF OFF ON OFF CFM 1430 1415 1410 1385 1330 (450 CFM/TON) WATTS 415 475 520 575 580 NOTES: 1. " First Letter may be "A" or "T" 2. *' Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE PRODUCT DATA American Standard Heating & Air Conditioning *UD2C080A9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 782 762 751 748 737 LOW ON ON TEMP. RISE 49 51 51 51 52 WATTS 75 110 145 185 225 CFM 870 865 861 848 831 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 44 45 45 45 46 STAGE WATTS 90 125 175 215 255 CFM 962 974 963 938 914 HIGH OFF OFF TEMP. RISE 40 40 40 41 42 WATTS 110 155 200 245 290 CFM 1091 1092 1087 1092 1077 LOW ON ON TEMP. RISE 54 54 55 54 55 WATTS 145 190 245 305 355 CFM 1211 1243 1243 1244 1235 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 49 48 48 48 48 STAGE WATTS 190 255 310 370 430 CFM 1371 1388 1392 1385 1377 HIGH OFF OFF TEMP. RISE 43 43 43 43 43 WATTS 255 325 395 455 515 *UD2C080A9V4VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW ON ON OFF ON CFM 863 865 858 843 831 (350 CFM/TON) WATTS 90 130 175 220 255 NORMAL ON ON OFF OFF CFM 995 1005 989 973 956 2.5 (400 CFM/TON) WATTS 115 170 210 260 305 HIGH ON ON ON OFF CFM 1101 1112 1111 1107 1101 (450 CFM/TON) WATTS 150 200 255 305 360 LOW OFF ON OFF ON CFM 1031 1031 1026 1013 1003 (350 CFM/TON) WATTS 125 175 215 270 320 NORMAL OFF ON OFF OFF CFM 1163 1178 1188 1183 1178 3.0 (400 CFM/TON) WATTS 170 230 285 345 405 HIGH CFM 1319 1337 1344 1340 1336 (450 CFM/TON) OFF ON ON OFF WATTS 240 305 365 420 485 LOW ON OFF OFF ON CFM 1182 1206 1211 1211 1211 3.5 (350 CFM/TON) WATTS 200 240 295 350 420 NORMAL ON OFF OFF OFF CFM 1380 1401 1402 1402 1399 (400 CFM/TON) WATTS 255 325 390 460 515 HIGH ON OFF ON OFF CFM 1553 1566 1557 1558 1559 (450 CFM/TON) WATTS 350 425 500 560 645 LOW OFF OFF OFF ON CFM 1386 1401 1408 1402 1390 (350 CFM/TON) WATTS 255 330 395 460 520 NORMAL ** OFF OFF OFF OFF CFM 1590 1593 1591 1588 1576 4 ** (400 CFM/TON) WATTS 360 440 515 575 650 HIGH OFF OFF ON OFF CFM 1791 1808 1810 1808 1726 (450 CFM/TON) WATTS 360 615 615 775 800 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning *UD2C080B9V4VA FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 974 968 949 925 906 LOW ON ON TEMP. RISE 49 49 50 51 52 WATTS 133 285 202 254 304 CFM 1102 1112 1103 1083 1066 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 43 43 43 44 45 STAGE WATTS 93 144 201 255 305 CFM 1194 1217 1215 1200 1182 HIGH OFF OFF TEMP. RISE 40 39 39 40 40 WATTS 119 180 243 304 362 CFM 1189 1210 1209 1193 1175 LOW ON ON TEMP. RISE 58 57 57 58 58 WATTS 142 209 276 341 404 CFM 1346 1388 1398 1390 1372 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 51 49 49 49 50 STAGE WATTS 141 207 274 339 401 CFM 1460 1516 1536 1533 1515 HIGH OFF OFF TEMP. RISE 47 45 45 45 45 WATTS 186 263 335 407 477 *UD2C080B9V4VA FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW ON ON OFF ON CFM 842 819 789 756 740 (350 CFM/TON) WATTS 71 114 163 207 249 NORMAL ON ON OFF OFF CFM 956 948 928 901 884 2.5 (400 CFM/TON) WATTS 90 140 196 248 298 HIGH ON ON ON OFF CFM 1071 1078 1067 1045 1028 (450 CFM/TON) WATTS 113 171 233 292 348 LOW OFF ON OFF ON CFM 1002 1000 983 958 942 (350 CFM/TON) WATTS 99 152 210 265 318 NORMAL OFF ON OFF OFF CFM 1140 1155 1150 1132 1114 3.0 (400 CFM/TON) WATTS 128 191 256 319 379 HIGH OFF ON ON OFF CFM 1278 1311 1316 1305 1287 (450 CFM/TON) WATTS 165 238 308 377 444 LOW CFM 1163 1181 1177 1161 1143 3.5 (350 CFM/TON) ON OFF OFF ON WATTS 134 199 265 328 389 NORMAL CFM 1324 1363 1372 1363 1345 (400 CFM/TON) ON OFF OFF OFF WATTS 179 255 326 397 466 HIGH ON OFF ON OFF CFM 1485 1544 1566 1565 1546 (450 CFM/TON) WATTS 234 319 396 472 550 LOW CFM 1324 1363 1372 1363 1345 (350 CFM/TON) OFF OFF OFF ON WATTS 179 255 326 397 466 NORMAL ** OFF OFF OFF OFF CFM 1508 1570 1594 1593 1575 4 — (400 CFM/TON) WATTS 243 329 407 483 562 HIGH CFM 1691 1777 1816 1824 1805 (450 CFM/TON) OFF OFF ON OFF WATTS 322 416 499 579 669 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE PRODUCT DATA American Standard Heating & Air Conditioning *UD213100A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 751 796 817 832 838 LOW ON ON TEMP. RISE 64 61 59 58 57 WATTS 86 132 175 218 263 CFM 862 921 953 967 954 HEATING 1ST MEDIUM " ON OFF TEMP. RISE 56 52 51 50 50 STAGE WATTS 121 185 233 285 322 CFM 959 1002 1036 1036 1003 HIGH OFF OFF TEMP. RISE 50 48 46 46 48 WATTS 148 210 280 325 355 CFM 1099 1124 1149 1157 1055 LOW ON ON TEMP. RISE 67 66 64 64 70 WATTS 227 287 355 415 395 CFM 1286 1321 1313 1215 1119 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 58 56 56 61 66 STAGE WATTS 365 450 455 475 450 CFM 1399 1419 1347 1265 1163 HIGH OFF OFF TEMP. RISE 53 52 55 59 64 WATTS 465 570 545 520 485 *UD2B100A9V3VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW ON ON OFF ON CFM 516 536 551 547 530 (350 CFM/TON) WATTS 50 75 105 135 165 NORMAL ON ON OFF OFF CFM 583 615 633 621 618 1.5 (400 CFM/TON) WATTS 59 92 127 157 18 HIGH ON ON ON OFF CFM 681 697 701 709 712 (450 CFM/TON) WATTS 70 110 140 180 215 LOW OFF ON OFF ON CFM 680 726 735 741 745 (350 CFM/TON) WATTS 75 120 150 190 230 NORMAL OFF ON OFF OFF CFM 769 819 843 858 865 2.0 (400 CFM/TON) WATTS 103 145 190 235 286 HIGH OFF ON ON OFF CFM 882 938 961 975 970 (450 CFM/TON) WATTS 130 190 245 300 345 LOW ON OFF OFF ON CFM 831 903 928 935 935 (350 CFM/TON) WATTS 180 180 230 275 320 NORMAL ON OFF OFF OFF CFM 979 1036 1053 1053 1015 2.5 (400 CFM/TON) WATTS 167 240 295 345 368 HIGH ON OFF ON OFF CFM 1121 1147 1176 1167 1055 (450 CFM/TON) WATTS 245 310 383 442 396 LOW OFF OFF OFF ON CFM 1061 1081 1095 1101 1032 (350 CFM/TON) WATTS 210 265 320 382 380 NORMAL ** OFF OFF OFF OFF CFM 1185 1223 1251 1205 1101 3.0** (400 CFM/TON) WATTS 278 364 435 455 426 HIGH OFF OFF ON j OFF j CFM j 1351 1372 1343 1248 1168 (450 CFM/TON) WATTS 425 503 535 505 1 480 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 10 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning *UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 900 890 870 850 835 LOW ON ON TEMP. RISE 53 54 55 57 58 WATTS 100 130 175 220 270 CFM 1125 1090 1060 1070 1070 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 43 44 46 45 45 STAGE WATTS 150 200 235 300 340 CFM 1300 1300 1320 1350 1340 HIGH OFF OFF TEMP. RISE 37 37 36 36 36 WATTS 220 290 365 430 490 CFM 1270 1290 1290 1290 1280 LOW ON ON TEMP RISE 59 58 58 58 58 WATTS 200 260 335 1 400 460 CFM 1575 1600 1610 1600 1580 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 47 46 46 46 47 STAGE WATTS 355 445 520 575 650 CFM 1870 1890 1860 1870 1730 HIGH OFF OFF TEMP. RISE 40 39 40 40 43 WATTS 560 665 710 830 760 *UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW CFM 1075 1055 1015 1000 990 (350 CFM/TON) ON ON OFF ON WATTS 135 185 220 265 325 NORMAL ON ON OFF OFF CFM 1220 1200 1210 1210 1210 3.0 (400 CFM/TON) WATTS 185 240 295 350 410 HIGH ON ON ON OFF CFM 1390 1390 1410 1410 1400 (450 CFM/TON) WATTS 245 320 391 470 510 LOW OFF ON OFF ON CFM 1214 1210 1215 1210 1210 (350 CFM/TON) WATTS 185 240 295 350 415 NORMAL OFF ON OFF OFF CFM 1430 1460 1470 1460 1440 3.5 (400 CFM/TON) WATTS 310 355 430 500 555 HIGH OFF ON ON OFF CFM 1640 1665 1650 1640 1610 (450 CFM/TON) WATTS 370 460 540 615 660 LOW ON OFF OFF ON CFM 1405 1430 1440 1440 1420 (350 CFM/TON) WATTS 270 310 375 480 550 NORMAL ON OFF OFF OFF CFM 1670 1675 1670 1655 1630 4.0 (400 CFM/TON) WATTS 395 490 550 630 700 HIGH CFM 1870 1880 1880 1845 1670 (450 CFM/TON) ON OFF ON OFF WATTS 540 635 730 800 640 LOW CFM 1775 1800 1820 1800 1680 (350 CFM/TON) OFF OFF OFF ON WATTS 480 580 680 750 740 NORMAL ** OFF OFF OFF OFF CFM 2065 2020 1945 1805 1623 5.0 '* (400 CFM/TON) WATTS 755 840 900 880 800 HIGH OFF OFF ON OFF CFM 2310 2100 2100 1965 1800 (450 CFM/TON) WATTS 1000 1000 950 890 825 NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 11 PRODUCT DATA American Standard Heating & Air Conditioning *UD2C100139V5VA FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 953 944 936 908 887 LOW ON ON TEMP. RISE 50 50 51 52 54 WATTS 93 146 193 243 292 CFM 1142 1141 1135 1112 1098 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 42 42 42 43 43 STAGE WATTS 135 200 255 322 377 CFM 1258 1260 1256 1236 1227 HIGH OFF OFF TEMP. RISE 38 38 38 38 39 WATTS 169 240 302 378 437 CFM 1312 1317 1314 1294 1287 LOW ON ON TEMP. RISE 52 52 52 53 53 WATTS 188 261 326 1 406 468 CFM 1577 1592 1592 1597 1582 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 44 43 43 43 43 STAGE WATTS 301 387 468 563 644 CFM 1739 1761 1762 1753 1762 HIGH OFF OFF TEMP. RISE 39 39 39 39 39 WATTS 392 486 575 675 774 *UD2C100B9V5VA FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW ON ON OFF ON CFM 1056 1050 1044 1019 1002 (350 CFM/TON) WATTS 114 173 225 284 336 NORMAL ON ON OFF OFF CFM 1199 1199 1194 1172 1161 3.0 (400 CFM/TON) WATTS 151 219 277 349 405 HIGH ON ON ON OFF CFM 1342 1348 1345 1326 1320 (450 CFM/TON) WATTS 198 273 340 422 486 LOW CFM 1223 1224 1219 1198 1187 (350 CFM/TON) OFF ON OFF ON WATTS 158 227 287 361 418 NORMAL OFF ON OFF OFF CFM 1389 1397 1395 1377 1373 3.5 (400 CFM/TON) WATTS 217 294 363 449 515 HIGH CFM 1556 1570 1570 1556 1559 (450 CFM/TON) OFF ON ON OFF WATTS 291 376 455 549 629 LOW CFM 1389 1397 1395 1377 1373 (350 CFM/TON) ON OFF OFF ON WATTS 217 294 363 449 515 NORMAL ON OFF OFF OFF CFM 1580 1595 1595 1582 1585 4.0 (400 CFM/TON) WATTS 303 389 469 565 647 HIGH CFM 1770 1793 1795 1787 1797 (450 CFM/TON) ON OFF ON OFF WATTS 411 507 598 698 801 LOW CFM 1723 1744 1754 1735 1744 (350 CFM/TON) OFF OFF OFF ON WATTS 382 475 564 663 760 NORMAL** OFF OFF OFF OFF CFM 1961 1991 1996 1991 2010 5.0 " (400 CFM/TON) WATTS 546 652 751 850 981 HIGH OFF OFF ON OFF CFM 2199 2217 2217 2197 1987 (450 CFM/TON) WATTS 754 875 983 1067 943 NOTES: 1. * First letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning *UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 1007 1062 1084 1063 1063 LOW ON ON TEMP. RISE 57 54 53 54 54 WATTS 114 177 285 303 350 CFM 1154 1211 1211 1221 1212 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 50 48 48 47 48 STAGE WATTS 167 230 277 344 417 CFM 1288 1319 1310 1349 1358 HIGH OFF OFF TEMP. RISE 45 44 44 43 43 WATTS 208 273 330 410 460 CFM 1387 1421 1455 1488 1495 LOW ON ON TEMP. RISE 64 63 61 60 59 WATTS 250 320 400 460 540 CFM 1589 1637 1666 1678 1541 HEATING 2ND MEDIUM "" ON OFF TEMP. RISE 56 54 53 53 58 STAGE WATTS 350 440 535 600 575 CFM 1771 1788 1804 1751 1554 HIGH OFF OFF TEMP. RISE 50 50 49 51 57 WATTS 475 560 650 675 590 *UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW OFF ON OFF ON CFM 1195 1243 1235 1251 1251 (350 CFM/TON) WATTS 150 225 275 325 410 NORMAL OFF ON OFF OFF CFM 1353 1403 1417 1437 1458 3.5 (400 CFM/TON) WATTS 210 290 370 425 485 HIGH OFF ON ON OFF CFM 1554 1572 1615 1634 1567 (450 CFM/TON) WATTS 315 410 480 570 575 LOW ON OFF OFF ON CFM 1356 1391 1399 1433 1454 (350 CFM/TON) WATTS 200 280 370 420 510 4 NORMAL ON OFF OFF OFF CFM 1565 1584 1633 1639 1554 (400 CFM/TON) WATTS 320 410 475 560 575 HIGH ON OFF ON OFF CFM 1766 1799 1810 1784 1590 (450 CFM/TON) WATTS 450 550 650 685 600 LOW OFF OFF OFF ON CFM 1708 1758 1759 1775 1575 (350 CFM/TON) WATTS 420 530 585 675 585 NORMAL ** OFF OFF OFF OFF CFM 1994 2018 1971 1814 1618 5 ** (400 CFM/TON) WATTS 665 775 785 725 625 HIGH OFF OFF ON OFF CFM 2247 2152 2019 j 1861 j 1693 (450 CFM/TON) WATTS 975 925 860 765 680 NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 13 PRODUCT DATA American Standard Heating & Air Conditioning *UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING S4-3 S4-4 0.1 0.3 0.5 0.7 0.9 CFM 1050 1044 1035 1005 980 LOW ON ON TEMP. RISE 45 46 46 47 48 WATTS 99 146 208 252 310 CFM 1214 1216 1217 1192 1169 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 39 39 39 40 41 STAGE WATTS 129 188 262 252 310 CFM 1288 1293 1298 1275 1254 HIGH OFF OFF TEMP. RISE 37 37 37 37 38 WATTS 147 212 293 309 373 CFM 1429 1440 1453 1435 1416 LOW ON ON TEMP. RISE 48 48 47 48 48 WATTS 191 267 363 340 406 CFM 1672 1695 1722 1711 1697 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 41 40 40 40 40 STAGE WATTS 310 402 528 409 480 CFM 1782 1809 1890 1835 1871 HIGH OFF OFF TEMP. RISE 39 38 36 37 37 WATTS 385 480 623 565 644 *UD2D120B9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING S3-1 S3-2 S3-3 S3-4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW OFF ON OFF ON CFM 1208 1209 1210 1185 1162 (350 CFM/TON) WATTS 128 186 260 306 370 NORMAL OFF ON OFF OFF CFM 1343 1350 1358 1337 1317 3.5 (400 CFM/TON) WATTS 162 232 318 365 433 HIGH OFF ON ON OFF CFM 1477 1491 1507 1490 1472 (450 CFM/TON) WATTS 210 290 391 436 508 LOW ON OFF OFF ON CFM 1343 1350 1358 1337 1317 (350 CFM/TON) WATTS 162 232 318 365 433 NORMAL ON OFF OFF OFF CFM 1496 1511 1528 1511 1494 4.0 (400 CFM/TON) WATTS 218 300 403 447 520 HIGH ON OFF ON OFF CFM 1650 1671 1698 1686 1671 (450 CFM/TON) WATTS 296 387 511 548 626 LOW OFF OFF OFF ON CFM 1612 1631 1655 1642 1627 (350 CFM/TON) WATTS 274 363 482 521 598 NORMAL ** OFF OFF OFF OFF CFM 1858 1902 1907 1906 1871 5.0 *' (400 CFM/TON) WATTS 403 533 624 714 755 HIGH OFF OFF ON OFF CFM 1871 2126 2110 2098 2001 (450 CFM/TON) WATTS 585 711 797 888 953 NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 1. *FIRST LETTER MAY BE "A" OR "T" 2. **FACTORY SETTING. 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 14 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA American Standard Heating & Air Conditioning *UD2D140A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 1090 1100 1070 1080 1060 LOW ON ON TEMP. RISE 62 61 63 62 63 WATTS 130 175 215 255 290 CFM 1230 1265 1280 1300 1300 HEATING 1ST MEDIUM ** ON OFF TEMP. RISE 55 53 53 52 52 STAGE WATTS 180 235 315 380 455 CFM 1380 1405 1425 1430 1450 HIGH OFF OFF TEMP. RISE 49 48 47 47 47 WATTS 235 290 375 415 520 CFM 1545 1550 1560 1560 1575 LOW ON ON TEMP. RISE 67 67 67 67 66 WATTS 320 385 475 540 605 CFM 1760 1790 1810 1800 1725 HEATING 2ND MEDIUM ** ON OFF TEMP. RISE 59 58 58 58 60 STAGE WATTS 435 545 620 695 725 CFM 2000 2010 2000 1950 1800 HIGH OFF OFF TEMP. RISE 52 52 52 54 58 WATTS 615 715 790 820 775 *UD2D140A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) LOW OFF ON OFF ON CFM 1175 1165 1180 1170 1150 (350 CFM/TON) WATTS 165 200 265 320 400 NORMAL OFF ON OFF OFF CFM 1345 1370 1400 1405 1380 3.5 (400 CFM/TON) WATTS 225 285 360 440 490 HIGH OFF ON ON OFF CFM 1525 1565 1585 1575 1530 (450 CFM/TON) WATTS 295 390 470 515 585 LOW ON OFF OFF ON CFM 1320 1330 1335 1300 1240 (350 CFM/TON) WATTS 220 275 355 435 490 NORMAL ON OFF OFF OFF CFM 1550 1580 1590 1555 1460 4.0 (400 CFM/TON) WATTS 310 400 475 540 610 HIGH ON OFF ON OFF CFM 1735 1735 1710 1670 1590 (450 CFM/TON) WATTS 430 510 600 675 710 LOW OFF OFF OFF ON CFM 1700 1725 1730 1725 1690 (350 CFM/TON) WATTS 415 470 560 640 700 NORMAL** OFF OFF OFF OFF CFM 1980 1980 1950 1885 1735 5.0 ** (400 CFM/TON) WATTS 616 710 770 780 735 HIGH OFF OFF ON OFF CFM 2190 2150 2075 1905 1735 (450 CFM/TON) WATTS 835 870 890 800 735 NOTES: 1. * First Letter may be "A" or "T" 2. ** Factory setting 3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 15 PRODUCT DATA WIRING DIAGRAM JUNCTION BOX c= GR- ,sa oN¢ GND H LBK- •WH•-+ -BK/2-1r -WH- - -BK/3 •-•WH• ' L WH/1 L - - -- J SEE NOTE 4 RIPORTANT: INTEGRATED CONTROL IS POLARITY SENSITIVE. HOT LEG OF 120V POWER SUPPLY MUST BE CONNECTED TO THE BLACK POWER LEAD AS INDICATED ON WIRING DIAGRAM. r BK BK/6- ORrto n PRESSURE GR MOTOR RD RD/6- SWITCH #} WH 3 WH/6- YL _ I IST STAGE GND OR YL ' PRESSURE _ SWITCH OR/I I 2ND STAGE \ Ba LIMIT SWITCH } TCO-A2NDSTAGE IBL/I VE GAS L RD/1 REDUNDANT DC>—MOo]�c7 _ MANUAL RESET FLAME r I ROLLOUT SWITCH � I _ J MANUAL RESET FLAME YL/4 J FRS ROLLOUT SWITCH FRS BK/5 WH - - - - - - FLAME - 2 WH/5 SENSOR HSI BURNER COMPARTMENT DOOR SWITCH �� SEE NOTE 13 BLOWER COMPARTMENT BK{� _ BK/I BK/2 _ LC % B K/ 3--��--I �•• B K/ 8 WH/1 ICM GR/BK INDOOR _ FAN WIRE BUNDLE r r s I MOTOR R JUMP e' ■ I I Q Q Q Q I Q O GND YL/BK TO ICM FAN DIP SWITCHES W2 DELAY S7-I, 57-2 S7-1 S7-2 TIME OFF OFF OFF- ON OFF 10 MINUTES OFF ON AUTO ON ON 20 MINUTES HEAT OFF DELAY S7-3, S7-4 S7-3 S7-4 TIME OFF OFF 90 SECS - OFF ON 120 SECS ON OFF 150 SECS ON ON 180 SECS HEAT PUMP S5-1 ON HEAT/COOL$ OFF HEAT PUMP DEHUMIDIFIER S5-2 ON INOT INSTAL OFF I INSTALL . FACTORY SETTING PIN I (BLUEPIN 9 (ORANGE) PIN 8--A SPIN 16 VIEW A -A DETAIL OF POLARIZED PLUG CONNECTIONS TO LED LIGHTS TERMINAL END TO TO 'M u � EW RN *0 EX CPC xw CONTROL ■ ' S7 WH/5 IGN-N ■ 1 ® WH/6 ND-N RD/6 IND-LO OFF ON BK/6 IND-HI ■ 6K/5 IGN-H ' S5 ■ _® _TNS BK/4�� ' OFF ON 120V 241 ■ S6 WH/4 ' LAST O " - ERROR INTEGRATED FURNACE RD RD ■ CONTROL (IFC) BL/I 8L SEE ���1i�� GR DIAGNOSTIC �`oa��ma��— r ,• ® ® LOW VOLTAGE TERMINAL • 1 --OR/I 1■11■11■11■11■1►� ►� ►� 1■1 �� DHUM m TO "G" i THERMOSTAT YLO Y W W2 R G C 0 SEE NOTES 2,3,5,6,7,8,9,10 ' TCO-B ■ ' REVERSE FLOW SWITCH ' r YL/3--o-_ YL/5 ■ OR BL IL WH BR OR/I I MVH 5 TH 9 TR 2 PS2 6 HLI 10 GND 3 FP 7 MVL II HLO 4 N/A 8 MV COM 12 PSI From Dwg. D344249PO2 16 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 SCHEMATIC DIAGRAMS PRODUCT DATA 115 VOLT 60 HZ. I PH POWER SUPPLY PER LOCAL CODE 1_1 'H �GR�6GND DOOR SWITCH BK ' IFC �N WH/I I LINE-H BK/I LC Y CI RC H 18K/1,�--� I SEE WH/1 ICM NOTE #4 rGR/BK FD NOR I I EACH 1 BK/2 MO fOR JUMP I HUM-H BK/3 �j YL/BK I XMFR-H I-BK/4::� TO ICM FAN CIR -N WH/1 CONTROL LINE N WH/I I XMFR-N WH/4 EAC-N I JE:120 24V: I HUM-N 1 I IND-HI 2 BK/6 I BK VENT m IND-LO 3 IRD16 RD MOTOR WH WW IND-N q WH/6 IGN-H 118K/5 IGN-N 5 WH/5 HSI I TR 9 BL TH 5 RD FLAME FP 3 tWH SENSOR GND 10 GR r HLO 11 t, L157 0 YLI3E>-�YL/4 J INOT USED 4 1 TCO-BB PSI FRS TCO-A FRS PSI 12 OR:::::: r� YL/I r�I Y L / 2 HL 1 6 YL L _ J PS2 2 t BR PS2 MVH 1 RIBR/I I MV COM 8 BL/I — ' r 3 HI I MVL 1 RD/I GAS 2 C VALVE I L----L _ PM. 1 I IBK/TWIN W2W1 R G B/C Y YLO0 1 1 1 I I 1 I I TO ICM I 1 1 1 1 I I I I r— FAN MOTOJ W2 WI R G BIC Y YLO 0 THERMOSTAT I U D L n V _\ SEE NOTES 2,3,5,6,7,8,9,10 TABLE W MODELS •UD2606OA9V3V•- •UD2608OA9V3V•- •UD2CO8OA9V4V•- •UD2CO8OB9V4V•• •UD2BIOOA9V3V•- •UD2CIOOA9V5V•• •UD2CIOOB9V5V•• •UD2D120A9VSV•• •UD2D12OB9V5V•- •UD2D14OA9V5V•- • PREFIX MAY BE "A' OR "T" • SUFFIX MAY BE "A" THROUGH "Z' WARNING HAZARDOUS VOLTAGE: DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ®CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EOUIPMENT. dAGNOSTIC CODES RED LED FLASH: I FLASH : FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 2 FLASHES: 3 FLASHES: PRESSURE SWITCH STUCK CLOSED IST-STAGE PRESSURE SWITCH STUCK OPEN/ NOT CLOSING 4 FLASHES: OPEN THERMAL LIMIT OR INTEGRATED FURNACE CONTROL OPEN ROLLOUT REPLACE WITH PART CNT06015 OR EQUIVALENT 5 FLASHES: 6 FLASHES: OPEN LOW VOLTAGE FUSE IST STAGE PRESSURE SWITCH ELECTRICAL RATING OPENED 5 TIMES WITHIN ONE CYCLE INPUT: 25 VAC, 60 HZ. --I HOUR LOCKOUT XFMR SEC. CURRENT: 450 MA. T FLASHES: SYSTEM LOCKOUT (RET RYI MV IST STAGE OUTPUT: I.5 A @ 24 VAC 8 FLASHES: SYSTEM LOCKOUT (RECYCLEI MV 2ND STAGE OUTPUT: 0.5 A @ 24 VAC 9 FLASHES: REVERSE POLARITY IND OUTPUT: 2.2 FLA, 3.5 LRA @ 120 VAC 10 FLASHES:GAS OR POOR GROUNDING VALVE ENERGIZED CIRC. BLOWER OUTPUT: 14.5 FLA, WITH NO CALL FOR HEAT 25 LRA @ 120 VAC 12 FLASHES:IGNITOR RELAY FAILURE INTERNAL HUMIDIFER & AIR CLEANER IN BOARD. REPLACE 'IFC' MAX. LOAD: 1.0 A @ 120 VAC SOLID :GAS VALVE RELAY FAILURE INTERNAL IGNITER OUTPUT: 2.0 A @ 120 VAC 3 DOUBLE: IN BOARD. REPLACE 'IFC' 2ND STAGE PRESSURE SWITCH OPEN TIMINGS REVERTS TO IST STAGE HEAT IGN WARMUP: 20 SEC. AMBER LED FLASHM RETRIES: 2 RECYCLES: 10 1 FLASH : IST STAGE CALL FOR HEAT HEAT ON DELAY: 45 SEC. 2 FLASHES: 2ND STAGE CALL FOR HEAT COOL ON DELAY: 2 SEC. 3 FLASHES: W2 CALL PRESENT WITH NO WI 4 FLASHES: Y PRESENT WITH NO G CALL RAPID : LOW FLAME SENSE CURRENT GREEN LED FLASH: I FLASH: STANDBY MODE OF CALL FOR COOLING 0-7 TCO THERMAL CUT OUT LINE BK BLACK GR GREEN )FACTORY 24 V J WIRING WH WHITE �131 BR BROWN o�o PS PRESSURE _ _ .LINE YL �OR YELLOW RD RED SWITCH l FIELD ORANGE BLUE 2q y f WIRING FRS FLAME ROLLOUT WIRE COLOR SWITCH •• INTERNAL THERMAL BK/I PROTECTION LNUMBER ID (IF ANY) Q- FP FLAME SENSOR p y/ CHASSIS GROUND 1 OR L LINE CF CAPACIT 'f` N HE TH TR 24 VAC (HOT) 24 VAC (COMMON) V V HSI HOT SURFACE 0 GND GROUND MV MAIN GAS VALVE IGNITER p BIC COMMON TNS TRANSFORMER r COIL HLO HIGH LIMIT OUTPUT o O DOOR SWITCH b HLI HIGH LIMIT INPUT NOTES: I. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105 C. 2. THERMOSTAT HEAT ANTICIPATOR SETTING: FIRST STAGE.38 AMPS, SECOND STAGE 13 AMPS. IF SETTING IS NOT FIXED ON THERMOSTAT, FOR SINGLE STAGE HEATING THERMOSTAT SET AT .51 AMPS. 3. FOR PROPER OPERATION OF COOLING SPEED, "Y' TERMINAL MUST BE CONNECTED TO THE ROOM THERMOSTAT. 4. THESE LEADS PROVIDE 120V POWER CONNECTIONS FOR ELECTRONIC AIR CLEANER (EAC) AND HUMIDIFIER (HUM). MAX. LOAD: 1.0 AMPS EACH. 5. WHEN USING A SINGLE STAGE HEATING THERMOSTAT, THE 2ND STAGE HEAT DELAY IS CONTROLLED BY S1-I & S1-2. REFERENCE THE SERVICE FACTS FOR DIP SWITCH CONFIGURATIONS. 6. GREEN LIGHT (CFMI FLASHES ONCE PER 100 CFM COMMAND. 1. FOR HEAT PUMP SYSTEMS Y AND 0 MUST BE CONNECTED TO THE LOW -VOLTAGE TERMINAL BOARD. 8. FOR TWO COMPRESSOR SYSTEMS, USE 'YLO" FOR LOW SPEED AND "Y' FOR HIGH SPEED CONNECTION TO THE LOW -VOLTAGE TERMAINL BOARD. FOR TWO STEP SCROLL SYSTEM, USE "Y' FOR LOW SPEED AND 'BK" FOR HIGH SPEED CONNECTIONS ON THE LOW VOLTAGE TERMINAL BOARD. PLACE A JUMPER BETWEEN 'R" AND '0" AND MOVE 'S5-2' TO THE 'OFF' POSITION. 9. OPTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN 'R" & ..BK". DO N07 CUT ANY JUMPERS ON THIS BOARD.SWITCH'S5-2'MUST BE SET IN THE'OFF'POSITION IF HUMIDISTAT IS USED. THE 'S5-2' SWITCH MUST ALSO BE TURNED TO 'OFF' WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO "BK'. THE "BK' TERMINAL MUST BE USED WHEN APPLYING A HUMIDISTAT, A 402 THERMOSTAT (WITH "BK" ENABLED), A TWO STEP SCROLL COMPRESSOR OR RESIDENTIAL ZONING SYSTEM. 10. A JUMPER MUST BE PLACED BETWEEN "R" & "0' TO ENABLE THE "BK" CIRCUIT OR ENHANCED MODE (COMFORT R). THIS "R" TO "0" JUMPER MUST BE IN PLACE FOR HUMIDISTAT DEHUMIDIFICATION AND PROPER BLOWER OPERATION WITH A TWO STEP SCROLL COMPRESSOR. II. SEE INDOOR MOTOR AIRFLOW SELECTION CHART, LOCATED IN THE FURNACE FOR DIP SWITCH SETTINGS TO SET AIRFLOW AND COOLING OFF DELAYS. 12. POWER MUST BE OFF WHEN DIP SWITCHES ARE SET. 13. USED ON ALL DOWNFLOW VARIABLE SPEED MODELS EXCEPT FOR •DD2BO6OA9V3V•• AND •DD2BO80A9V3V••. From Dwg. D344249PO2 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 17 PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY NOTES: I. BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATEISI I GROUND I 2. LOW VOLTAGE124 V. WIRING) TO BE NO. 18 A.W.G. MIN. SCREW 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. FURNACE 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. II BK JUNCTION 5. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC 1 I I AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH. I r J 1 BOX I G. WHEN A SINGLE STAGE HEATING THERMOSTAT WITHOUT FAN SWITCH LH BK r IS USED, NO WIRING ON "G" TERMINAL IS USED. Toll' , W`i/I 7 SECOND STAGE HEAT AND W2 MUST BE JW IILLEREBEGIN�0 MINUTES FOR AFTER PROPER FIRSTRSTAGE. 60 HZ.POWER I I SUPPLY PER 1 J 1 8. SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS LOCAL CODES LN WH L TO SET AIRFLOW AND INDOOR FAN OFF DELAYS. B1/3 9. CONTINOUS FAN AIRFLOW CAN BE INCREASED BY ADDING THIS JUMPER. riJ I WH 1 HUM SEE NOTE BK L FURNACE INTER -COMPONENT WIRING BI�/2 WH I r J 1 24 V' FACTORY EACSEE Jr -----LINE V.}WIRING NOTE 5 L BK --� DIP SWITCH 24 V. � FIELD I I LINE V. WRING INTEGRATED FURNACE oNl I FACTORY CONTROL 0�00 0�00 INSTALLED THERMOSTAT TERMINALS oFF JUMPER _ SINGLE STAGE HEATING 6 I THERMOSTAT WITH FAN I G W2 W1 R o Y YLo RN R I SWITCH TERMINALS. FIELD ADDED JUMPER SEE NOTE SEE NOTE 9 I I SEE NOTE 6 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING GROUND SCREW -- BK ) 1 rJ I I 1 LH BK O115 V 1 PH., Toll ' W�1/I 60 HZ.POWER , 1 r J SUPPLY PER L N WH 1 L LOCAL CODES Bj/3 r WH r J j HUM SEE J NOTE 5 1L BK B112 EAC SEE rJ I BK NOTE 5 � BK L L --� I From Dwg. 21 B341127 Rev. 0 NOTES: FURNACE BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE(S) JUNCTION 2. LOW VOLTAGE(24 V. WIRING) TO BE NO. 18 A.W.G. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. B 0 X 1 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH. 1 6. SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS TO SET AIRFLOW AND INDOOR FAN OFF DELAYS. 7. CONTINOUS FAN AIRFLOW CAN BE INCREASED BY ADDING THIS JUMPER. I I INTER -COMPONENT WIRING ____________24 V. ---- R NG FACTORY FURNACE -LINE V. 24 V. FIELD DIP SWITCH LINE V.1 WRING INTEGRATED FURNACE ON CONTROL DON THERMOSTAT TERMINALS SEE Ir NOTE ) I T1 1 I FACTORY INSTALLED JUMPER 2 STAGE HEATING THERMOSTAT WITH FAN SWITCH TERMINALS. From Dwg. 21 B341126 Rev. 0 18 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) ------------------ GROUND scREw FURNACE i SK i�JUNCT ION BOX LH BK WH/I' i0 IIS V I PH., fi0 HZ. POWER SUPPLY PER LOCAL CODES LN WH B$/3 r WM HUM SEE 1 BR r r III NOTE 5 L r WB EAC SEE I BH ' NOTE 5 L n I DIP SWITCH NTEGRATED o" 000 0 000 FURNACE CONTROL POWER THERMOSTAT TERMINALS 6.,X- SUPPLY G W2 MI B D Y YLO BK R rI"h I i}r8 o NOTES: I. BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE(S) 12. LOW VOLTAGE (24 V. WIRING) TO BE NO. 18 A.W.G. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. ,4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 15. THESE LEADS PROVIDE III V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD I.0 AMPS EACH. I6. THIS WIRE IS ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL. 7. THE "Y" TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE "Y" TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING. I8. SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS TO SET AIRFLOW AND INDOOR FAN OFF DELAYS. 19. OPTIONAL HUMIDISTAT I$ TO BE CONNECTED BETWEEN R AND BK. FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED. THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BK INPUT SUCH AS WITH THE VARIABLE SPEED, SINGLE -ZONE AND MULTI -ZONE SYSTEM CONTROLLERS, ON SINGLE SPEED COOLING ONLY/NON-HEAT PUMP SYSTEMS, JUMPER Y TO 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUMIDISTAT. FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS, JUMPER YLO TO 0. INTER -COMPONENT WIRING —24 V. FACTORY —LINE V.} WIRING 24 V. FIELD FURNACE LINE v. I WRING SINGLE STAGE HEATING / COOLING ,THERMOSTAT WITH FAN SWITCH TERMINALS. Q Q QQI00 I J I FIELD ADDED JUMPER ` SEE _ L_-_-_-J iSEE NOTE 6 NOTE 7 LOW VOLTAGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER From Dwg. 21 B341125 Rev. 1 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) I I GROUND SCREW FURNACE i�pJUNCTION Box III 8K Wy/I' r0 IS v xZ., I POWER SUPPLY PER LOCAL CODES LN WH %/3I WH HUM SEE BK r NOTE 5 L fK/�1 WH EAC SEE BN + NOTE 5 � POWER SUPPLY I Y J l J LOW VOLTAGE AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER INTEGRATED oFF L FURNACE CONTROL THERMOSTAT TERMINALS G W2 11 B G ®Y SEE NOTE NOTES: _ I. BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE(S) 2. LOW VOLTAGE(24 V. WIRING) TO BE N0. I8 A,W.G. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH. 6. THIS WIRE IS ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL. I7. THE "Y" TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE "Y" TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING. I8. SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS TO SET AIRFLOW AND INDOOR FAN OFF DELAYS. 9. OPTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN R AND BK. FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED. THE ON MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE 8K INPUT SUCH AS WITH THE VARIABLE SPEED,SINGLE-ZONE AND MULTI -ZONE SYSTEM CONTROLLERS, ON SINGLE SPEED COOLING ONLY/NON-HEAT PUMP S VS TEMS, JUMPER Y TO 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUMIDISTAT. FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS, JUMPER YLO TO 0. INTER -COMPONENT WIRING -24 V. FARCTORY - - _ _ _ - - - -LINE V.} DIP SWITCH e FURNACE 241 LINE V. FIELD WRING 000 0000 1j�F 2 STAGE HEATING SINGLE pEpieo STAGE COOLING THERMOSTAT WITH YLO fin K " FAN SWITCH TERMINALS. ®® SEE \NOTE 6 R v 6 rl wz G i j From Dwg. 21 B341124 Rev. 1 12-1095-09 DATA SUBJECT TO CHANGE WITHOUT NOTICE 19 PRODUCT DATA FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) I GROUND SCREW ®� FUR NACE �I I BIK JUNCTION rJ j BOX LH BK W /I TO 115 V 1 PH., I 60 HZ., POWER J SUPPLY PER LOCAL CODES LN WH L BK/3 I WH J HUM SEE NOTE 5 [:B:IK l BIK /2 WH r J EAC SEE NOTE 5 BK --� DIP SWITCH POWER SUPPLY 1 1 I 1 a _UNIT INTEGRATED oFF 00�0 00�0 FURNACE CONTROL I B L y� POWER SUPPLY I I THERMOSTAT TERMINALS FACTORY 0 W2 WI B 0 Y YLO BK R-JUMPER E UNIT 2 B SEE NOTE 7 L _Y_T I LOW VOLTAGE -- -- AIR CONDITIONING OUTDOOR SECTION WITHOUT TRANSFORMER I I I 1SEE �NDTE INTER -COMPONENT WIRING ------------24 V -----LINE 24 V L INE FURNACE FACTORY V, WIRING V}FIELD WRING 2 STAGE HEATING TWO STAGE COOLING THERMOSTAT WITH FAN SWITCH TERMINALS. NOTES: I. BE SURE POWER AGREES WITH EQUIPMENT NAMEPLATE(S) 2. LOW VOLTAGE(24 V. WIRING) TO BE NO. 18 A.W.G. MIN. 3. GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. SET THERMOSTAT HEAT ANTICIPATOR PER UNIT WIRING DIAGRAM. 5. THESE LEADS PROVIDE 115 V. POWER FOR CONNECTION OF ELECTRONIC AIR CLEANER AND HUMIDIFIER MAX. LOAD 1.0 AMPS EACH. 6. THIS WIRE IS ONLY FOR THERMOSTATS REQUIRING CONNECTION TO TRANSFORMER COMMON TERMINAL. 7.THE "Y2" TERMINAL FROM THE THERMOSTAT MUST BE WIRED TO THE "Y" TERMINAL OF THE FURNACE CONTROL FOR PROPER BLOWER OPERATION DURING COOLING. 8. SET DIP SWITCHES WITH POWER OFF PER INSTALLATION INSTRUCTIONS TO SET AIRFLOW AND INDOOR FAN OFF DELAYS. 9. OPTIONAL HUMIDISTAT IS TO BE CONNECTED BETWEEN R AND BK. FACTORY INSTALLED JUMPER R TO BK ON THE CIRCUIT BOARD MUST BE CUT IF OPTIONAL HUMIDISTAT IS USED. THE JUMPER MUST ALSO BE CUT WHEN APPLYING AN AIRFLOW COMMAND SIGNAL TO THE BK INPUT SUCH AS WITH THE VARIABLE SPEED SINGLE -ZONE AND MULTI -ZONE SYSTEM CONTROLLERS, ON SINGLE SPEED COOLING ONLY/NON-HEAT PUMP SYSTEMS, JUMPER Y TO 0 FOR PROPER OPERATION OF THE DELAY PROFILES AND THE HUM IDISTAT. FOR TWO COMPRESSOR OR TWO SPEED SYSTEMS, JUMPER YLO TO 0. From Dwg. 21 B341128 Rev. 0 20 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-09 S °a a N AUD-9V OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) 04 DIAMETER a FLUE CONNECT OUTLET DIM C" A R MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS DIM "B- 0 7/8 KNOCK OUT UPFLOW CLOSET ELECTRICAL CONNECTION LEFT SIDE 0 IN. FRONT 3 IN. (SEE NOTE I) (ALTERNATE) RIGHT SIDE +0 IN. BACK IN. 19-5/8 3-31/32 FLUE #6 IN. TOP I IN. I -------------------- OUT HORIZONTAL CLOSET (SEE NOTE2) 5/8 TOP +2 IN. BACK 3 IN. 7/8 HOLE 3-IS/16 (ALTERNATE) FLUE #6 IN. SIDES 1 IN. FRONT 18 IN. (SEE NOTE I) ELECTRICAL CONNECTION ' � I/2 5 5/I6 -------------------------------------------------- HORIZONTAL ALCOVE ISEE NOTE 2) TOP +1 IN. BACK 0 IN. - /2 HOLE 2-1/I6 FLUE #6 IN. SIDES 0 IN. FRONT 18 IN. . GAS CONNECTION q q g q q q 2-I/16 ------ ------------------------------------------- # - MAY BE I" WHEN TYPE B-1 VENT IS USED ° + - FOR 14-1/2" CABINETS 3" WHEN SINGLE WALL VENT PIPE IS USED. WHEN 14-1/2" CABINETS (ALL *UD040C-, - - *UD060ORI AND *UD060ARE ° 2-I/8 —"—"—"—' ^ ^ ^ ^ INSTALR-, NVENT INCHND A ' o PIPOENISLUSEDD,POSITION6 SNNGIE WALLLED CLEARANCE MUST BE SUPPLIED BETWEEN -5/I6 0 30-5/8 32 • THE VENT PIPE AND COMBUSTIBLE FLOORING. NOTES28-I/4 28-I/4 ° 1) MINIMUM CLEARANCE TO FRONT ON *UD140R960AND *UD140C960 IS 6INCHES. SIDE 22-1/2 S I D E TALLEDONCOMBUSTIBLE14 2) MAY BEINSRETURN 7/8 L0l I FLOOR WHEN TYPE B-VENT IS USED. o� RETURN14-7/8 AIR 1° -..-..-..-..--..-..-..-..-4 °1 AIR I-9/II 6 �16 DIM "A" 23-3/4 1-5/I6 23-3/4 1/2 28-1/2 BOTTOM DIM "D" RETURN AIR MODEL A B C D *UD2B060A9V3V** 17-1/2" 9-5/8" 16-1/4" 16" *UD2B080A9V3V** *UD2B100A9V3V** *UD2C080A9V4V** *UD2C100A9V5V** 21" 13-1/16" 19-3/4" 19-1/2" *UD2C080B9V4V** *UD2C100B9V5V** *UD2D120A9V5V** 24 1/2" 15 5/16" 23 1/4" 23" *UD2D14OA9V5V** *UD2D12OB9V5V** First Letter May Be "A" or "T" Suffix Letters May Be "K" (0 Through 9) From Dwg. C341699 va n PRODUCT DATA ,¢merf600 S*odard HEATING & AIR C O N D I T I O N I N G Since the manufacturer has a policy of continuous product and product data improvement, it rese rves the right to change the design and specifications without notice. Technical Literature - Printed in U.S.A. American Standard Heating & Air Coditioning 6200 Troup Highway Tyler, TX 75707 \NIERTFR CM C US G/STEO