Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2025-0231_Other_2.14.2025_10.13.37_AM_4763122
Job Name: System Reference: Date: Indoor Unit SVZ-KP18NA Unit, ............................................................................ Outdoor Unit SUZ-KA18NAHZ ..................................................................... INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 In.WG (Tested per ASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (up or down) • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control • Built-in humidifier control, ERV control and auxiliary heat control • Optional downflow kit • Multiple control options available: o kumo cloud° smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • H2i® hyper heat performance offers 100% heating capacity at 5° F • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life • Built-in base pan heater • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal BTU/H 18,000 BTU/H 18,000 BTU/H 9,360 W 1,440 W 1,440 Pints/h 1.1 0.93 96.0 / 96.0 Sensible Heat Factor Power Factor [208V / 230V1 % Heating at 47°F' Maximum Capacity BTU/H 28,000 Rated Capacity BTU/H 21,600 Minimum Capacity BTU/H 8,800 Maximum Power Input W 3,140 Rated Power Input W 1,880 Power Factor [208V / 230V1 % 97.0 / 97.0 Heating at 17°F' Maximum Capacity BTU/H 21,600 Rated Capacity BTU/H 14,300 Maximum Power Input W 2,740 Rated Power Input W 1,810 Heating at 5°F4 Maximum Capacity BTU/H 21,600 Maximum Power Input W 3,600 Efficiency SEER I SEER2 18.4 1 18.7 EER' I EER2' 12.5 1 12.4 HSPF [IV] I HSPF2 [IV] 10.419.2 COP at 47°F2 3.3 COP at 17°F at Maximum Capacity' 2.31 COP at 5°F at Maximum Capacity4 1.75 Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 20 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 3.0 Fan Motor Full Load Amperage A 2.4 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 471-573-675 Airflow Rate at Heating, Dry CFM 471-573-675 Sound Pressure Level [Cooling] dB[A] 33-36-41 Sound Pressure Level [Heating] dB[A] 33-36-41 External Static Pressure in.WG 0.30-0.5-0.8 Drain Pipe Size In. [mm] 3/4 [19.05] Coating on Heat Exchanger — External Finish Color Hot -dip coated steel (ZAM) Unit Dimensions W x D x H: In. [mm] 17 x 21-5/8 x 39-13/16 [432 x 549 x 1,011] Package Dimensions W x D x H: In. [mm] 17 x 28-3/4 x 44-3/8 [460 x 730 x 1,011] Unit Weight Lbs. [kg] 93 [42] Package Weight Lbs. [kg] 106 [48] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 68 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB 159 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 'Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): * System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 17.0 A 31 Fan Motor Full Load Amperage A 1 Fan Motor Output W 60 Airflow Rate [Cooling / Heating] CFM 2,020 / 1,930 LEV Refrigerant Control Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 55 Sound Pressure Level, Heating2 dB(A) 55 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB220FQGMT Compressor Rated Load Amps A 13 Compressor Locked Rotor Amps A 16.0 Compressor Oil (Type // Charge] oz. FV50S // 23.7 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm] 33-1/16 x 13 x 34-5/8 [840 x 330 x 880] Package Dimensions W x D x H: In. [mm] 38-3/4 x 16-3/4 x 39 [980 x 420 x 990] Unit Weight Lbs. [kg] 131 [59.5] Package Weight Lbs. [kg] 150 [68] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock -out / Re -start Temperatures** °F -25 / -14 Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 3.0, 12.0 Maximum Pre -Charged Piping Length Ft. [m] 100.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0 [0] Piping Gas Pipe Size O.D. [Flared] In.[mm] 1/2 [12.7] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 100 [30] Maximum Height Difference Ft. [m] Maximum Number of Bends 50 [15] 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17*F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Control Interface Airzone ZBS Wired Blueface Principal Controller White Airzone ZBS Wired Blueface Principal Controller White Airzone ZBS Wired Lite Controller White Airzone ZBS Wireless Lite Controller White Airzone ZBS Wireless Think Controller White BACnet® and Modbus® Interface CN24 Relay Kit Connector cable for remote display IT Extender kumo station® for kumo cloud® ❑ AZZBSBLUEFACECB ❑ AZZBSBLUEZEROCB ❑ AZZBSLITECB ❑ AZZBSLITERB ❑ AZZBSTHINKRB ❑ PAC-UKPRC001-CN-1 ❑ CN24RELAY-KIT-CM3 ❑ PAC-SA88HA-EP ❑ PAC-WHS011E-E ❑ PAC-WHS01 HC-E Remote Operation Adapter= ❑ PAC-SF40RM-E Thermostat Interface ❑ PAC-US444CN-1 Thermostat Interface ❑ PAC-US445CN-1 USNAP Adapter ❑ PAC-WHS01UP-E Wireless Interface for kumo cloud® ❑ PAC-USWHS002-WF-2 Flush Mount Remote Temperature Sensor ❑ PAC-USSEN002-FM-1 Flush Mount Temperature Sensor ❑ PAC-USSEN001-FM-1 Remote Sensor Remote Temperature Sensor ❑ PAC-SE41 TS-E Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert ❑ PAR40MAAU Simple Ductless Wired Remote Controller ❑ PAC-SDW01 RC-1 Wired Remote Controller Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch' RedLINK' Wireless Controller ❑ MHK2 Wireless Remote Controller Wireless MA Receiver ❑ PAR-FA32MA-W Wireless MA Remote Controller ❑ PAR-FL32MA-E Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H ❑ X86-003 Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H ❑ COMBI 20/2PR, 1 PR shielded + 1 PR plenum wire for Airzone, 100 Itreel ❑ CW2042S2-100 Control Wire 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel ❑ CW2042S2-500 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Downflow Kit Downflow Kit ❑ DFK-S Electric Heat Lockout Electric Heat Lockout ❑ ETC-211020-MIT 3kW Electric Heater ❑ EH03-SVZ-S Electric Kit Heats 5kW Electric Heater ❑ EH05-SVZ-S 8kW Electric Heater ❑ EHO8-SVZ-S 100' x 1/4" x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-100 15' x 1/4" x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-15 Lineset 30' x 1/4" x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-30 50' x 1/4" x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-50 65' x 1/4" x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-65 Terminal Block Separate Terminal Power Block ❑ SPTB1 NOTES: *PAC-SF40RM-E (Unable to use with wireless remote controller) Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide M- & P-Series Maintenance Tool Cable Set 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ MAC-886SG-E Control/Service Tool ❑ M21 EC0397 Mini -Split Wire ❑ S144-250 ❑ SW144-250 ❑ S144-50 ❑ SW144-50 ❑ S164-250 ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Mounting Pad Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Optional Defrost Heater Base Heater ❑ MAC-642BH-U1 18" Single Fan Stand ❑ QSMS1801 M 24" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. o26 Knockout Hole (Indoor / Outdoor unit connection) (Remote controller transmission) Left side view Unit:mm(in.) view o26 Knockout Hole 026 Knockout Hole for electrical heat wiring 2-o4.6 Burring Holes for electric heat installation IIL Secondary nining) 19.05(3/4) 3/4"FPT- left) Secontlary drain pipe Secondary drain pipe (oEm.ngency Craning) (Emergency draining) t 9.05(3/4) 3/4"FPT o19.05(3/4) 3/4"FPT (Horl—tal Right) Model Nominal Filter Size Duct Connection SVZ-KP12NA 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA 508 x 508 x 25.4 (20 x 20 x 1) 477 x 402 (18-13/16 x 15-7/8) SVZ-KP36NA Bottom Tr view ]J Prima�rr(vyv drain)pipe 019 0 (3/4) 374"FPT Control box "(Remove Blower Panel) Unit:mm(in.) Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. Right side view Model A B C D E F G H J Gas Pipe Liquid pipe SVZ-KP12NA 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1,010.8 (39-13/16) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) o 9.52 (3/8) o 6.35 (1/4) SVZ-KP18NA 0 12 7 (1/2) SVZ-KP24NA SVZ-KP30NA 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) o 15.88 (5/8) o 9.52 (3/8) SVZ-KP36NA Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 22 it v M FORM# SVZ-KP18NA & SUZ-KA18NAHZ - 202304 Unit: inch REQUIRED SPACE "1 20 in. (500 mm) or more when front U and sides of the unit are clear and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (09/12 KBTU/H) Refrigerant pipe (flared) o 1/2 (15/18 KBTU/H) 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com M - ; 0%."s Intertek Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.