Loading...
BLD2025-0264_Structural_Calculations_2.24.2025_10.59.47_AM_4776129ID TYPICAL INITIAL CONDUCTOR FINAL CONDUCTOR CONDUCTOR CONDUIT # OF CURRENT -CARRYING CONDUIT OCPD EGC TEMP. CORR. CONDUIT CONT. MAX. BASE DERATED LENGTH VOTAGE LOCATION LOCATION PARALLEL CONDUCTORSIN FILL FACTOR FILL CURRENT CURRENT AMP. AMP. DROP CIRCUITS CIRCUIT PERCENT FACTOR 1 1 ARRAY JUNCTION BOX 12 AWG Q CABLE - - 1 2 N/A N/A 6 AWG BARE 0.82 (48°C) N/A 9.68A 12AA N/A N/A 30FT 0.30% COPPER 2 1 JUNCTION BOX IQ COMBINER BOX 4 10 AWG THWN 2 COPPER MIN 0.75" DIA 1 2 14.26 % 20A 8 AWG THWN-2 1 (26°C) 1 9.68A 12AA 35A 35.00A 35FT 0.36% EMT COPPER 3 1 IQ COMBINER BOX 4 NON FUSED AC 10 AWG THWN 2 COPPER MIN 0.75" DIA 1 3 18.01% N/A 8 AWG THWN-2 1 (26"C) 1 9.68A 12.1A 35A 35.00A 5FT 0.05% DISCONNECT EMT I COPPER 4 1 NON FUSED AC MSP 10 AWG THWN 2 COPPER MIN 0.75" DIA 1 3 1&01% 20A 8 AWG THWN-2 1 (26°C) 1 9.68A 12AA 35A 35.00A 5FT 0.05% DISCONNECT EMT I COPPER BRANCH 1 08- LONGI LR5-54HABB 395M (HI -MO 5) MODULES JUNCTION BOX Q CABLE 1 600 V, NEMA 3R, ILL LISTED 0 FL I — — — — — — — — — — — — --� -- (08) ENPHASE IQ8PLUS-72-2-US (240) MICROINVERTERS PEAK OUTPUT POWER 300VA TERMINATOR CAPS INSTALLED ON END OF CABLE METER NO#: 1000600699 SCALE: NTS PRODUCTION CT'S GATEWAY 0 (N) AC DISCONNECT: �240V, 30A NON -FUSED 3 / NEMA 3R, UL LISTED N L-------$�— — ---z— — c 2 (N) ENPHASE IQ COMBINER BOX 4C (X-I Q-AM 1-240-4 C) WIRELESS COM KIT CELL MODEM INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 20A = 220A BUSS RATING X 120% 225A x 120% = 270A TO UTILITY GRID O(N) BI-DIRECTIONAL UTILITY o METER# 1000600699 1 -PH, 3-W, 120V/240V (N) MAIN BREAKER TO HOUSE 240 V, 20OAl2P (N) MAIN SERVICE PANEL, 225A RATED, 1-PH,3-W,240V z � N BACK FEED BREAKER AT 4 THE OPPOSITE END OF THE MAIN BREAKER L J EXISTING GROUND ELECTRODE CONDUCTOR SYSTEM RATING 3.160 kWDC 2.400 kWAC SERVICE INFO UTILITY PROVIDER: SNOHOMISH COUNTY PUBLIC UTILITY DISTRICT AHJ NAME: SNOHOMISH COUNTY MAIN SERVICE VOLTAGE: 240V MAIN SERVICE PANEL: 225 A MAIN BREAKER RATING: 200 A SERVICE FEED SOURCE: OVERHEAD SOLAR Al ARIZONA, USA PH# : (480) 524-1278 SYSTEM INFO (8) LONGI LR5-54HABB-395M (8) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE' 3 160 kWDC AC SYSTEM SIZE_ 2.400 kWAC METER: 1000600699 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS �O � U O N 00 J Q O N O U O7 0 > ao � Q W (n 0 p Z J cD O CV 0 W Z_ � 2i p LL Q p O Z J W J Z J p LU O F elf O — J_ Q n (') Lo 75 W DATE:2/10/2025 SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 I SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL LONGI LR5-54HABB-395M VMP 30.7 V IMP 12.87 A VOC 36.81 V ISC 13.65 A TEMP. COEFF. VOC -0.27%/K PTC RATING 369.3 W MODULE DIMENSION 67.79"(L) x 44.64"(W) PANEL WATTAGE 1395 W INVERTER SPECIFICATIONS MANUFACTURER / MODEL ENPHASE IQ8PLUS-72-2-US (240V) MAX DC SHORT CIRCUIT CURRENT 15 A CONTINUOUS OUTPUT CURRENT 1.21 A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -5°C AMBIENT TEMP (HIGH TEMP 2%) 26°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 48°C CONDUCTOR TEMPERATURE RATE 90°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX FOR BRANCH CIRCUIT #1 OF 8 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.30% VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4 VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 8) X (0.00129 OHMS/FT) X (35 FT X 2) = 9.68 AMPS X 0.00129 OHMS/FT) X 70 FT = 0.87 VOLTS %VRISE = 0.87 VOLTS - 240 VOLTS = 0.36% THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4 IS 0.36% VOLTAGE RISE FROM THE IQ COMBINER BOX 4 TO THE NON FUSED AC DISCONNECT VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 8) X (0.00129 OHMS/FT) X (5 FT X 2) = 9.68 AMPS X 0.00129 OHMS/FT) X 10 FT = 0.12 VOLTS %VRISE = 0.12 VOLTS = 240 VOLTS = 0.05% THE VOLTAGE RISE FROM THE IQ COMBINER BOX 4 TO THE NON FUSED AC DISCONNECT IS 0.05% VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) = (1.21 AMP X 8) X (0.00129 OHMS/FT) X (5 FT X 2) = 9.68 AMPS X 0.00129 OHMS/FT) X 10 FT = 0.12 VOLTS %VRISE = 0.12 VOLTS - 240 VOLTS = 0.05% THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.05% TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0.3% + 0.36% + 0.05% + 0.05% = 0.76% SOLAR Al ARIZONA, USA PH# : (480) 524-1278 SYSTEM INFO (8) LONGI LR5-54HABB-395M (8) ENPHASE IQ8PLUS-72-2-US (240V) DC SYSTEM SIZE 3 160 kWDC AC SYSTEM SIZE_ 2.400 kWAC METER: 1000600699 I REVISIONS DESCRIPTION I DATE I REV PROJECT NAME & ADDRESS Q :E U7 O � U O J 0 Q N O rn 19 0 L(D Qw J CD (n p z � N O o w 2 Q z z_ � p p J W z z J J O � p = of - d LL J_ O Q co75 Lo W DATE: 2/10/2025 SHEET NAME SPECIFICATIONS & NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8