Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2024-0109_Fire_Alarm_Equipment_Specification_Sheets_02-26-2025_13_56_20_37287353_-_North_Vista_Condos_CELL_2025-02-26_R1
FIRE ALARM COMMUNICATOR TRANSMISSION METHOD CHANGE SUBMITTAL NORTH VISTA CONDOS 645 BELL ST EDMONDS, WA 98020 AUTHORITY HAVING JURISDICTION CITY OF EDMONDS revision 1 - modify product documentation to reflect starlink cellular installation as AES signal strength was not compliant. 2025-02-26 by Performance Systems Prepared By: PERFORMANCE SYSTEMS INTEGRATION Pacific Northwest Puget Sound Portland Inland 301 Porter Way 7324 SW Durham Rd 4004 E Trent Ave Milton, WA 98354 Portland, OR 97224 Spokane, WA 99202 Licenses: 675521 (CA), CLE569 (OR), PERFOSI81250 (WA), PERFOSIS1850 (WA) Job #: 37287353 2024-10-18 TABLE OF CONTENTS 0. EQUIPMENT LIST 1. SCOPE OF WORK / INSTALLATION NOTES 2. SECONDARY POWER SUPPLY CALCULATIONS 3. TYPICAL CONFIGURATION 4. MANUFACTURER DATA SHEETS NICET REVIEW PRIMARY REVIEW/D.O.R ERIC HAMERSKI, 118193, EXPIRES 2027.12.01 SECONDARY REVIEW/LSSA WHEN APPLICABLE SCOTT LECLAIR, 118859, EXPIRES 2025.03.01. LSSA # 4623-LEA AS EMPLOYED BY PERFORMANCE SYSTEMS INTEGRATED, PORTLAND, OR. EQUIPMENT LIST AES INSTALLATION SUBJECT TO NFPA72 2019/2022ED 26.6.5.2 MANU/MODEL AES 7707 ELK TRG 1640 DURACELL SLA1212F2 CELLULAR INSTALLATION SUBJECT TO NFPA72 26.6.3 MANU/MODEL STARLINK SLE-MAX2-CFB-PS ELK TRG 1640 DURACELL SLA127F2 DESCRIPTION ONE WAY PRIVATE RADIO TRANSFORMER (OR EQUAL) BATTERY (OR EQUAL) DESCRIPTION DUAL PATH CELL COMMUNICATOR TRANSFORMER (OR EQUAL) BATTERY (OR EQUAL) 1. SCOPE OF WORK & INSTALLATION NOTES • NFPA72 2022 edition citations are more stringent than previous editions. Such citations comply with previous editions. • Install new fire alarm communicator adjacent to fire alarm control panel (FACP) in accordance with NFPA72 (2022ed) 26.6.5.2. • When applicable: provide connections to FACP onboard DACT (note: not all fire alarm panels employ a factory installed DACT) for full point annunciation. FACP DACT is not subject to the requirements of NFPA72 (2022ed) 26.6.4 (per 26.6.4.1.1) • Unless specifically codified in the subject jurisdictions municipal code, connections as a minimum to monitor general fire, general trouble, and when applicable general supervisory are optional and may be employed. • Communicator primary power supply shall be achieved via dedicated duplex receptacle with protective enclosure. Such AC circuit shall be dedicated, surge protected with a breaker lock. Typically, this receptacle is employed as an extension to existing FACP circuit. • Communicator shall not receive primary power from the FACP. • Secondary power supply shall be achieved via 12v battery. See additional calculation sheet. • Installation does not adversely affect FACP secondary power supply calculations. When applicable, an additional addressable input module may be employed to monitor trouble condition of communicator. • Installation does not modify existing/previously approved fire alarm system layout, components, design, or intent. • Installation does not modify the existing/previously approved sequence of operations. System will communicate if able, and trouble on the communicator shall generate local annunciation. • Any exterior antenna, when installed, shall be surge/lightning protected. 2. SECONDARY POWER SUPPLY CALCULATIONS AES INSTALLATION AES 7707 QUICENT LOAD — 0.175A AES INTELLIPRO QUICENT LOAD — 0.165A TOTAL 0.340A AES 7707/PRO ALARM LOAD — 0.752A TOTAL 0.752A STANDBY REQUIRED — 24 HOURS ALARM REQUIRED — 15 MINUTES (0.25 HOURS) BATTERY DERATING — 1.25 CALCULATION: 0.340 x 24 = 8.16 amp/hr, 0.752 x 0.25 = 0.19 amp/hr 8.16+0.19=8.35amp/hr 8.35 x 1.25 = 10.44 amp/hr AS SUCH — 12V 12AH BATTERY, DURACELL DURA12-12F2 OR EQUAL TO BE FURNISHED AND INSTALLED CELLULAR INSTALLATION NAPCO STARLINK SLE QUICENT LOAD — 0.085A TOTAL 0.085A NAPCO STARLINK SLE ALARM LOAD — 0.085A TOTAL 0.085A STANDBY REQUIRED — 24 HOURS ALARM REQUIRED — 15 MINUTES (0.25 HOURS) BATTERY DERATING — 1.25 CALCULATION: 0.085 x 24 = 2.040 amp/hr, 0.752 x 0.25 = 0.022 amp/hr 2.04 + 0.022 = 2.062 amp/hr 8.35 x 1.25 = 2.578 amp/hr AS SUCH — 12V 5AH BATTERY, DURACELL DURA12-5F2 OR EQUAL TO BE FURNISHED AND INSTALLED WHILE NFPA72 (2022ed) 10.6.7.2.12 REQUIRES AS A MINIMUM 5 MINUTES ALARM, PERFORMANCE SYSTEMS SPECIFIES 15 MINUTESPERTHEAESBATTERY CAL CULATOR SUPPLIMENTALAI/AILABLEATWWWAES-CORPCOM. BATTERYDERATING IN ACCORDANCE WITH NFPA72 (2022ed) 10 6.7.214. 3. TYPICAL CONFIGURATION CONNECT TO DIALER TERMINALS (WHEN APPLICABLE) CONNECT TO FACP ONBOARD RELAYS FOR GENERAL TROUBLE, GENERAL FIRE, GENERAL SUPERVISORY (WHEN APPLICABLE) OPTIONAL CONFIGURATION SHOWN AES IS LISTED TO EMPLOY INTELLITAP MODULE WITHOUT ONBOARD POINTS. DOES NOT PRECLUDE VOLUNTARY CONNECTIONS FOR OTHER GENERAL SIGNALS AES 7707 DETAIL SCALE: NONE SLE-MAX2-FIRE PC Board POWER SUPPLY INPUT CONNECT TO FACP ONBOARD Ez RELAYS FOR GENERAL TROUBLE, GENERAL FIRE TO FACP DACT (_) ETHERNET OUT1 INS EGND NiO C For Dry TBL n O RLV move _ shun[ O OQ �O ww O TRBL MONITORING CONNECT TO FACP ONBOARD RELAY(S) FOR GENERAL SUPERVISORY, OPTIONAL POINTS NAPCO STARLINK DETAIL SCALE: NONE 4. EQUIPMENT DATA SHEETS DURACELL SLA Batteries ULTRA Duracell® Ultra SLA technology offers performs traditional lead acid batterie construction is designed for efficient c maintenance -free operation. Duracell' their high capacity with a design that is resistant to damage caused by deep discharge. Every Duracell° Ultra SLA battery is inspected to ensure the highest standards in materials and fabrication. 50-150 Cycles at 100% Discharge S P I LL PROOF GUARANTEE Features: General Purpose Backup and deep cycle applications • Duracell° Ultra SLA GEL batteries contain a proprietary grid alloy formula combined with advanced plate curing techniques to provide maximum performance. • Duracell° Ultra batteries contain a unique electrolyte formula with a special sub -colloid additive for higher reliability and longer life. • Will achieve more life cycles than standard AGM and Deep Cycle batteries. • The unique construction and sealing techniques of these batteries are guaranteed to give you leak -proof operation. • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications, even after repeated over -discharges. • Quality Assurance Engineers monitor and control the entire production process. • Recycling of used SLA batteries available. • Delivery available. CASE on M❑C Quantities ❑❑❑❑ AVAILABLE ❑❑❑❑ Sealed Lead YEAR Acid Maintenance Free Spill Proof 1 Year Stringent Quality Design Warranty Control 0 batteriesplus.com 1-800-677-8278 DURACELL SLA Batteries ULTRA General Purpose AES - DURA12-12F2 STARLINK - DURA12-5F2 DURA12-0.8WL Volts 12V CapacityAh (20Hrs) 0.8 1.3 'a Dimensions (LxWxH Inches) 3.78 0.98 1 2.4 Terminal Type Group Size WL F1,T1 F1,T1 F1,T1 F1,T1 F1,T1 F1,T1 MT2 F1,T1 F1,T1 Weight (Lbs.) 0.77 1.37 DURA12-1.31' DURA12-2.31' DURA12-2.91' DURA12-3.31' DURA12-3.31`2 RAYA12-4F DURA12-51' DURA12-5F2 DURA12-5.1A 12V 3.82 1.69 2.28 12V 2.3 6.97 1.38 2.64 2.04 12V 2.9 3.11 2.2 3.9 2.36 12V 3.3 5.28 2.64 2.63 3.18 12V 3.3 - - 3.54 2.76 3.54 2.76 ® M 5.51 1.89 3.54 2.76 5.95 2.56 5.94 2.56 5.94 2.56 5.94 2.56 5.94 2.56 - - 12V 4 4.21 12V 5 4.21 M 1 M - 12V 5.1 4.21 4.6 DURA12-5.51' 12V 5.5 3.98 - RAYA12-7F DURA12-7F DURA12-71`2 DURA12-81' DURA12-81`2 DURA12-9NB DURA12-91`2 DURA12-10F2 12V 7 3.94 12V 7 3.94 F1,T1 12V 7 8 8 9 9 10 11 3.7 F2,T2 12V 3.94 F1,T1 12V 3.94 F2,T2 12V 5.95 2.56 3.9 3.94 NB,1 12V 5.95 2.56 F2,T2 - 12V 5.95 2.54 4.38 F2,T2 7.5 DURA12-11NB 12V 5.28 3.15 6.5 10.1 DLMA-1 =- DURA12-12F ■ ■ M ■ M - F1,T1 - 12V 12 5.94 3.86 3.86 - DURA12-14F2 12V 14 5.94 3.86 3.98 F2,T2 8.91 DURA12-181`2 12V 18 7.13 3.03 6.57 F2,T2 - DURA12-18NB 12V 18 7.13 3.03 6.57 NB,1 12.43 DURA12-26NB 12V 26 6.5 6.93 4.92 NB,1 20.7 DURA12-35C 12V 35 7.72 5.16 6.5 C 27.3 DURA12-44C/FR 12V 46 7.8 9.02 10.24 12.09 13.43 1.85 6.54 5.43 6.65 6.85 C 38 DURA12-55C/FR 12V 55 8.35 42.1 DURA12-80C/FR 12V 80 8.46 C - DURA12-100C/FR 12V 100 140 4.5 6.65 8.46 C 74.6 DURA12-140C/FR 12V 6.81 11.3 C 108 DURA4-4.5F2 4V 1.85 3.98 F2,T2 1.4 DURA6-1.3F 6V 1.3 3.82 0.94 2.28 F1,T1 0.715 DURA6-2ST DURA6-2.9F DURA6-3.3F 6V 2 1.69 1.45 1.46 2.99 ST 0.75 6V 2.9 3.3 4 5 2.6 3.82 F1,T1 1.26 6V 5.28 1.34 2.64 F1,T1 1.65 RAYA6-4F 6V 2.76 1.85 4.13 F1,T1 - DURA6-5SP 6V 2.6 2.6 4.53 SP 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 F1,T1 - DURA6-7.2F 6V 7.2 5.94 1.34 3.68 F1,T1 2.43 DURA6-8.2F 6V 8.2 3.9 2.24 4.53 F1,T1, 3.8 DURA6-1OF DURA6-12F DURA6-12F2 RAYA6-14T2 DURA6-14A DURA6-42F2 DURA6-42NB DURA6-200C DURA8-3.2F 6V 10 6V 12 6V 12 6V 14 6V 14 6V 42 6V 42 6V 200 8V 3.2 5.94 1.97 3.98 F1,T1 4.851 5.94 5.94 4.25 4.25 6.25 1.97 3.98 F1,T1 - 4.602 6.24 1.97 3.98 F2,T2 2.8 5.51 H 2.8 5.51 F1 () F2 (+), T1 (-) T2 (+), FP 6.16 3.37 6.37 F2,T2 16.64 6.34 3.43 6.42 NB,1 16.62 12.05 6.65 8.63 C - 1.65 5.28 1 1.44 1 2.48 1 F1,T1 Visit batteriesplus.com for warranty information Batteries-` Bulbs 0 2017 DURACELL, Bethel, CT 06801. Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved. • Easiest installation, powered by panel, NO extra power supply, NO extra conduit. (Excludes Metal Direct AC -Powered Model, shown below.) • Labor -Saving Supervision Features Save Time & Money - Uniquely including 4 supervised, programmable EOLR zone inputs; 2 Form C Relay outputs (no extra supervision modules to buy or install); plus, 2 Telephone style jacks for easy FACU-connection. Self -supervised on 4 wires. • Easy Account Management on www.napcocomnet.com365/2417&Easy-RepeatAccountTem plates - Save your typicaI account setup and reuse for goof -proof communicator programming Vast deployment. • Free StarLink FACU-SaverApp - Smartphone Pro sales tool for calculating/demonstratingaccount's cellular cost -savings _=- with dealer by number of lines & locations vs. copper POTs lines leased from phone co. FREE download on Apple Store or Google Play. • Pro Incentive Instant Rebate Program - Dealers save on new and retrofit installations, replacing POTS, old radios, sunset networks and even new installations. (Nothing to mail in/fill out; Service credit automatically applied upon valid plan activation.) • Supports Honeywell° CLSS • Over -the -Air Upgradeable Firmware • UL Listed & NFPA 72 Fire Code -Compliant, the Starl-ink Fire Max 2 Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal supportfor any brand 12V to 24Vfire alarm control panel (FACU), reporting in Contact ID and 4/2. UL-Listed from the UL 864 StarLink Fire Max 2 communicator, to Napco's NY UL 864 Network Operations Center (shown below in map), to any Central Station's UL Listed Receiver. (It is also backed by Disaster Recovery NOC in PA for immediate, mirrored emergencyswitchover.) Sta rLi n k Fi re MAX 2: SLE-MAX2-Series Dual SIM, Dual Path & Exclusive Super Dual'" • Dual SIM, Dual Path Universal full data 5G LTE-M cellular WorlP, or supervised dual cell (Super Dual'") commercial fire alarm reporting from any panel, virtually anywhere nationwide • One Model to Stock: Provides both Verizon® &AT&T" Cell Networks plus either sole or dual path cell/IP, -or- exclusive Super Duallm Supervised Dual Cell, Dual Channel Cell -Only Dual Path UL 864 reporting (Selectable by plan) • Auto -Network -Select by Site- Upon power up, the signal -strength provided by each cell carrier is analyzed at the site, and the unit will lock -in the best carrier automatically, ie.,AT&T orVerizon.Thereafter, it's periodically reviewed and dynamically swapped as needed. • EZ Cell -Network ID- Red or Blue Indicators - Inside the unit, the Carrier Indicators will light Blue for AT&Tor Red forVerizon connection (also test button indicates signal strength on each for manual check) • See/Set SIM Status Remotely - using a PC or smart device, the StarLink Network Operations Center(NOC), in Napco Headquarters, NY, can be accessed allowing you used to set parameters or view current status, Dual SIM status of accounts • Supports 12V-24V FACUs, No Panel Reprogramming with those that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup. • UL & NFPA Code -compliant, replaces 2 POTs lines per FACU saves thousands of dollars per year over the leased landlines. (Show accounts savings - Free Sales Tool/Calculator App) • Proven StarLink Reliability & Best 5G LTE-M Performance - Works where others can't - Signal Boost" Circuitry & unique dual -diversity twin antennas, maximizing signal acquisition and eliminating the multiphase -effect signal-clash/drop-outs single -antenna units are prone to. tnA,a.,,a °o�eaMod<fio�<Pam One Dual SIM Dual Path Model is Both Verizon and AT&T and Sole or Dual Path with Cellular + Internet Option. Starl-ink Fire provides full data reporting, in sole & dual path, as a primary or backup, to any central station of your choice, w/o requiring any special equipment. Super Dual- Exclusive Supervised Dual Cell, Dual Path Plan Option (w/o using IP) Industry's 1st UL 864 Listed Supervised Dual Sim, Dual Path Communications - Uses 2 cell networks; both carrier channels are supervised. If one network is down, the other will be on. UL 864 Listed Dual Supervised, Dual Cell Channels, avoids use of IP forAHJ/regions' dual path requirement. A selectable plan option on NapcoComnet.com Easy, Universal Installation at Every Application. Starl-ink Fire Communicators are easily connected to any 12Vto 24V panel or Fire Alarm Control Panel (FACU) using easy Quick -Connect FACP modularjacks. Starl-ink Fire Max 2 Series comes in standard,ABS plastic Panel -Powered Technology" (powered by the panel), models, or in metal housings w/ or w/o & choice of power options, i.e., direct -connect 120VAC or Plug-in transformer. StarLink Fire is End -to -End UL 864 Listed to protect signal reliability, speed & performance for critical life and safety alarm reports for maximum life safety & liability protection. STARLINK: ALL SIGNALS, ALWAYS IN THE USA StarLink UL Listed End to End: UL 864 Listed Starl-ink Fire Communicator ►► UL 864 Napco NY NOC w/ PA Failover: SOC "Any Central Station's UL Receiver • Dual SIM models auto -select optimal cell carrier- "„asM, and Red or Blue LED Indicators inside signal °"' Verizon or AT&T respectively, shown right. H • LED Status /Trouble Indicators 3 Radio Status LED Indicators (visible from outside standard model housin )-Green, Si nal Strength; Amber- Busy/Activation; Red-Troub e. (Additions internal LEDs, not visible with cover closed, i.e., for troubleshooting and for AT&TorVerizon network selection, status). Power LED indicator viewable on outer metal enclosure models. • Sole or Dual Path 5G LTE-M Cell Commercial Fire Alarm Communicator in One -Simply select Cell or Cell/IP or Super Dual' Service Plan & check -in period: 5 minutes, 60 minutes, 6 hours or 24 hours. • Signal Boost and Patented Dual Diversity Antenna for maximum signal acquisition & null/signal-clash avoidance, receiving signals on both antennas (2 Antennas supplied, nothing extra to buy.) • "Return Receipt" Fully -Supervised Communication Path between premise & central station, keeping channel open until kiss -off is received from Central Station Receiver SPECIFICATIONS: (Apply to all modelsstated) SLE-MAX2-FIRE & SLE-MAX2-CFB: Electrical Ratings for +12V/ 24V(Models w/o Power Supply) • Input Voltage:10-24VDC regulated (power -limited output from ULCertified FACU/panel AuxlRemote Fire Power). • Input Current: 24VDC standby: 85mA SLE-MAX2-CFBPS: • Input Current: 200mA maximum • Maximum Charging Current: 200mA Electrical Ratings Fire Input 1: • InputVoltage: 9-25VDC • Max Input Current: Up to 2mAfrom FACU NAC circuit Electrical Ratings for Inputs 2 to 5 (Class B): • Maximum Loop Current:1.2mA(metal models);1.7mA(plastic) • End of Line Resistor (EOLR) Value: 10K Electrical Ratings for P6M3 Output: • Open Collector Output: MaxVoltage 3V when active; 25V max. when not. • PGM Max Sink Current: 50mA(up to 15VDC), 25mA (15.lVDC-25VDC) • Plastic Housing: 8 x 51/2 x 11/2 "(WHD) + antennas (tea, supplied) 81/4" H • Metal Housing:111/2 x 91/2 x 31/2"(WHD) + antennas (tea, supplied) 81/4" H • Housings: 2 Keyholes forwall mount • Operating Temp. 32 to 1201, 93% Humidity Max. COMPLIANCES: NFPA72 Ed,:- Qii J& QJJ Jill IWO; UL2610, UL985, UL1023, UL86410th Ed., CSFM, NYC FD, LAFD N0FL 11UMVIR VFCICLIUI13 LVIRCI(NOC) UL 86410th Ed.,UL 1610, UL 1635 Napco's Exclusive Super aua1TM The Industry's 15tSupervised Cell, Dual Path W Uses Dual Cell Networks, Verizon +AT&T, With Both Carrier Channels Supervised Super Reliability - If One Network Goes Down, the Other Will be On. Super Easy Labor -Saving Option Anywhere Dual Path is Required, e.g., NYC, L.A., Chicagoland, Denver, IN, etc. t UL Listed 864 Dual Cell Performance Satisfies Spec w/ 2 Supervised Cell Carrier Paths Reporting, But Without Requiring IP & the Associated IT -Hassles & Time Easy Upgrade to any StarLink Fire MAX 2 on Napcocomnet.com - Just Select "SUPER DUAL" Plan StarUnk FIRE MRM W SLE-WIFI-MODULE: Optionally connects supported dual path models to Internet via WiFi, eliminating Ethernet cable connection. Requires 7AH battery. (see WI2191) SLE-ANTEXT30: StarLink Omni-X Optional Extended Range Marine -Grade Complete Antenna Kit, wl 30' of ultra low -noise LIAR 300 cable, all hardware & ground fault isolator plate. TRF12: Plug in AC Transformer, used w/ SLE-MAX2-CFBPS model, (use subject to local code). SLE-FMBB: Opt.Metal Cable Management Backbox for surface mounting plastic Starl-ink communicator models adjacentto FACUs on same plane. Radio easily snaps in on 4 stand-offs, no rewiring. Red metal enclosure wl3/4" cable knockouts; 2 Connectors & 4" Conduit, supplied. Addressable, Conventional Fire Alarm Systems & Leading Commercial Fire Cellular Communications tFor Compliance, Always Consult with AHJ &Tech Docs by Model, i.e., SLE-MAX2-FIRE (Plastic) W12609LF; SLE-MAX2-CFBPS,-CFB (Dual Path Metal) W12642LF. Starl-ink, StarLinkMAX Fire & Super Dual" are trademarks of NAPCO Security Technologies, Inc. Other marks remain intellectual property of their respective companies. For Pro Incentive Promo see detai Is on ine. Preliminary data & promotions subject to change without notice.© NAPCO 2024.4 A852A