Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2025-0019_Fire_Alarm_Equipment_Specification_Sheets_3.3.2025_8.07.10_AM_4788001
Johnson * Controls Johnson Controls Fire Protection 12781 Gateway Drive Tukwila, WA 98168 Phone: 206-291-1400 www.JohnsonControls.com Building Systems Submittal Package Holy Rosary Parish FACP Replacement 760 Aloha St Edmonds, WA 98020 Project Description Fire Alarm System Revision Date: 2-26-25 Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Scope Replace existing 5808 Silent Knigh FACP with a new 6808 Silent Knight Fire Alarm Control Panel. All existing equipment and wiring to remain as is. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls Equipment List & Data Sheets Fire Alarm System Product ID Product Description 6808 Silent Knight Fire Alarm Control Panel with Communicator Equipment List Subject to Change. Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Johnson * Controls This Page Left Blank Intentionally Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World Intelligent Fire Alarm Control Panel with Communicator The 6808 features a built-in SLC circuit, four Flexput° circuits, dual -line DACT, powerful software features, and connectivity for up to 17 panels. The 6808 is the latest intelligent addressable FACP (Fire Alarm Control Panel) from Silent Knight and is a direct replacement for the 5808 FACP. The 6808 has one SLC (signaling line circuit) loop for connecting addressable detectors, which can support 99 System Sensor' SK sensors and 99 SK modules or 127 Hochiki° SD devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. The built-in digital alarm communicator/transmitter (DACT) is dualtechnology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication overthe public switched telephone line. Optional cellular reporting is available. The 6808 has four onboard Flexput° circuits that can be configured as notification outputs or auxiliary power. There are four types of Aux power available: door holder, constant power, resettable power and sounder sync power. The 6808 also has form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. The 6808 supports a variety of devices, including 6860, 5860, or 6855 remote annunciators, 5824 seriaVparallel printer interface modules (for printing system reports), 5895XL power modules, and SK, SWIFT° wireless, or SD devices. FEATURES AND BENEFITS • Complies with UL 86410th Edition • Built-in support for up to 99 IDP/SK detectors and 99 IDP/SK modules or 127 SD SLC devices • Four Flexput circuits (3 amps max) for NAC outputs or auxiliary power • Selectable strobe synchronization for Amseco°, System Sensor, Wheelock', and Gentex° devices • 250 software zones and 250 output groups for flexible design options • Built-in dual phone line, digital alarm communicator/transmitter(DACT) with IP and optional cellular technologies • Four line LCD displaywith 20 characters per line • Built-in USB interface for quick and easy programming • JumpStart® auto programming reduces installation time • 13 preset notification cadence patterns (including ANSI° 3.41) • Allows up to 20 SBUS devices • Two programmable relays and one fixed trouble relay • Convenient field-upgradeablefirmware • Supports up to four SWIFT wireless gateways which can foster up to 49 wireless devices each • Connectivity for up to 17 sites • Network card allows copper network connection with a multi -mode or single - mode fiber connection • Programmable date setting for Daylight Savings Time • History file with 1,000 event capacity • Can be surface or flush -mounted Honeywell SILENT' I MGHT USERINTERFACE LED INDICATORS • General Alarm (Red) • Supervisory (Yellow) • System Trouble (Yellow) • System Silenced (Yellow • System Power (Green) KEYPAD • 12-key numeric pad • Acknowledge • Alarm Silence • System Reset • F1-F4 Programmable Function Keys PROGRAMMING The 6808 system offers several options to simplify and expedite programming. JumpStart auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on -site access to current system programming. System programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6808: Addressable fire alarm control panel, red COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciatorwith four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 5860R: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator. red 5865-3: LED annunciators can display up to 30 LEDs (15 red and 15 yellow) 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED 1/0 module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: Serial/Parallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same system. Refer to the Device Compatibility Document and SLC Wiring Manual for more information. SK-ACCLIMATE: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detectorwith extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1351F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1901F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10:10- input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detectorwith remote test capability, white SK-PHOTO-T: Photoelectric smoke detectorwith fixed thermal heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detector with fixed thermal heat (1350F), white SK-PTI R-W: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module SK BASES B21OLP: 6" mounting base B501: 4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounder base B224RB: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same system. SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector SD505-DUCTR: Addressable Duct Detector housing with relay base Page 2 of 4 — 351608:C • 3/10/2022 SD505-H EAT: Absolute temperature heat detector. Trip point range from 1351F-1501F (01C-371C) SD500-LIM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-HEAT: Wireless, fixed heat detector (135°F) with B501W base WSK-HEAT-ROR: Wireless rate -of -rise heat detector and B501W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFTTools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.farenhyt.com SYSTEM EXPANDERS 5895XL: 6A power supply with six Flexput circuits and two Form C relays 5496: 6A NAC power expander with four power -limited output circuits OPTIONAL COMMUNICATORS HWF2A-COM: Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T HWF2V-COM: Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorALARM° receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6808 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet SK-SCK: Seismic compliance kit to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° -based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel's USB port using a flash drive. Requires a PC running Microsoft' Windows®. Page 3 of 4 — 351608:C • 3/10/2022 6808 TECHNICAL SPECIFICATIONS SYSTEM CAPACITY TEMPERATURE AND HUMIDITY Intelligent Signaling Line Circuits:1 Addressable device capacity:198 (SK) or 127 (SD) Programmable software zones: 250 Output circuits: 4 (expandable) SBUS Devices: 20 (12 annunciators, 8 LED modules) ELECTRICAL AC Power:120 VAC, 60 Hz, 3.3 A Standby Current:190 mA Alarm Current: 250 mA Flexput Circuits: Terminal block provides connections for (four Class B ortwo Class A) NACs or auxiliary power. Power -limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End -of -line resistor: 4.7k ohm,'/2 watt for Class B NACs Communication Loop: Supervised and power -limited, Class A or Class B, 32VDC, 150mA Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A C 27.4 VDC (resistive), Form C Battery: Cabinet holds maximum of two 18 AH batteries Battery Charger Capacity:17-55 AH PHYSICAL Dimensions:16.4" W x 26.4" H x 4.1" D (41.66cm W x 67.06cm H x 10.41cm D) Weight: 45 lbs. (20.4 kg.) Color: Red Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com RANGES This system meets NFPA requirements for operation at 0 — 49°C (32-1200F) and at a relative humidity 93%± 2% PH (non - condensing) at 320C ± 20C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 271C/60 — 80°F. NFPA STANDARDS The 6808 complies with the following NFPA 72 Fire Alarms Systems requirements: NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72 Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-0559:0502 FDNY: COA# 6246 FM Approved Seismic: (CA) VMA-45894-05C 351608 1 C 1 04-22 ©2022 Honeywell International Inc. Honeywell ®SILENT' KNIGHT Honeywell SILENT' IQVIGHT HONEYWELL SILENT KNIGHT 12 Clintonville Road Existing Detectors Northford, CT 06472 www.silentknight.com Addressable Detector and Sounder Base Compatibility Chart 1 1 1• l ,.Moun M. I .III' :,: SK White • Standard 0 SD505-PHOTO SD Ivory • • • s a Remote Test Capable SK-PHOTO-R-W SK White • • I • 1 • (for Duct Detectors) Thermal SK-PHOTO-T-W SK White • • • I • • • SK White • • • • • Fixed SD505-HEAT SD Ivory • • • • d x High Temperature SK-HEAT-HT-W SK White • • • Rate -of -Rise SK-HEAT-ROR-W SK White • • _ • R " Fire/CO SK-FIRE-CO-W SK White • • • • • c� Photo/ SK-PTIR-W SK White • • • 1 • • • 2 Thermal /IR Sounder Bases .III Series FACPs 0111160 5000 Series FACPs B20OS-WH SK White • • • • 1 • • Standard B20OS-IV SK Ivory • • • • • 1 SD505-6SB SD Ivory • • • • • B20OS-LF-WH SK White • • • • • • Low Frequency B20OS-LF-IV SK Ivory • • w • • • Notes on Protocols: The 5700, 5808, 5820XL, 5820XL-EVS, 6700, 6808, 6820 and 6820EVS FACPs support SK protocol or SD protocol SLC devices. The FACP must be programmed for either SK or SD protocol and all devices on the system must match the corresponding protocol. NOTE: FACPs must be programmed for only SK or SD mode of operation. Communication protocols cannot be split. Johnson * Controls This Page Left Blank Intentionally Fire, Security, Communications, Workforce Solutions, Sales Service Offices Representatives in Principle Cities throughout the World