Loading...
1622450_Manufacturer_Specifications_and_Installation_Instructions_03-05-2025_14_21_10_MSZGS15NA_MUZGS15NAHZJob Name: System Reference: Date: Indoor Unit MSZ-GS15NA Unit, ........................................................................... Outdoor Unit.................................................................... MUZ-GS15NAHZ ( .�a011111111Illlllllllllllli��, r�MffLfI IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIi 'Illllllllllliilllllllllllllll!!U' � �'''�i�Illlllllllllluu�'''� _ INDOOR UNIT FEATURES • Slim wall -mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: o Back -lit screen handheld remote controller (provided with the unit) o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Hyper -heating performance offers 100% heating capacity at 5°F • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet outdoor unit operation • Built-in base pan heater • Innovative DC fan motor leads to high efficiency and reliability • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTM B117 Standard Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal BTU/H 18,200 BTU/H 14,000 BTU/H 3,100 W 2,020 W 1,100 Pints/h 2.5 Sensible Heat Factor 0.80 93.0 / 93.0 Power Factor [208V / 230V1 % Heating at 47°F' Maximum Capacity BTU/H 2O,900 Rated Capacity BTU/H 14,000 Minimum Capacity BTU/H 4,800 Maximum Power Input W 2,030 Rated Power Input W 1,140 Power Factor [208V / 230V1 % 95.0 / 95.0 Heating at 17°F' Maximum Capacity BTU/H 16,800 Rated Capacity BTU/H 8,700 Maximum Power Input W 2,020 Rated Power Input W 950 Heating at 5°F4 Maximum Capacity BTU/H 14,000 Maximum Power Input W 2,150 Heating at -5°F' Maximum Capacity BTU/H 11,910 Heating at -13°F7 Maximum Capacity BTU/H 9,820 Efficiency SEER2 21.0 EER2' 12.75 HSPF2 [IV] 9.4 COP at 47°F2 3.6 COP at 17°F at Maximum Capacity' 2.44 COP at 5°F at Maximum Capacity4 1.91 COP at -5°F at Maximum Capacity' 1.62 COP at -13°F at Maximum Capacity? 1.33 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 15 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.75 Fan Motor Output W 30 Airflow Rate at Cooling, Dry CFM 191-253-316-400-504 Airflow Rate at Cooling, Wet CFM 172-228-285-360-454 Airflow Rate at Heating, Dry CFM 191-231-285-348-437 Sound Pressure Level [Cooling] dB[A] 26-32-38-44-49 Sound Pressure Level [Heating] dB[A] 26-30-35-40-46 Drain Pipe Size In. [mm] 5/8 [15.881 Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H: In. [mm] 31-7/16 x 9-1/8 x 11-5/8 [798 x 232 x 295] Package Dimensions W x D x H: In. [mm] 33-1/2 x 12 x 14 [850 x 300 x 3501 Unit Weight Lbs. [kg] 23 [10.4] Package Weight Lbs. [kg] 26 [11.5] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 10.0 A 15 Fan Motor Full Load Amperage A 0.5 1166 / 1152 Airflow Rate [Cooling / Heating] CFM Refrigerant Control LEV Reverse Cycle Defrost Method Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC inverter driven Twin Rotary Compressor Model SNB140FQUMT Compressor Rated Load Amps A 7.4 Compressor Locked Rotor Amps A 9.2 Compressor Oil [Type // Charge] oz. FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550] Package Dimensions W x D x H: In. [mm] 37 x 15 x 24-1/2 [940 x 380 x 630] Unit Weight Lbs. [kg] 85 [38] Package Weight Lbs. [kg] 92 [42] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -4 / 0 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock -out / Re -start Temperatures** °F -22 / -14 Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 2.0, 9.0 Maximum Pre -Charged Piping Length Ft. [m] 25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 1.08 [20] Piping Gas Pipe Size O.D. [Flared] In.[mm] 1/2 [12.70] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 65 [20] Maximum Height Difference Ft. [m] 40 [12] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47*F (Indoor // Outdoor) *F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5*F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): * System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Control Interface CN24 Relay Kit IT Extender kumo station® for kumo cloud® Procon BACnet® and Modbus® Interface System Control Interface USNAP Adapter Wireless Interface for kumo cloud® Wired Remote Sensor ❑ CN24RELAY-KIT-CM3 ❑ PAC-WHS011E-E ❑ PAC-WHS01 HC-E ❑ PAC-UKPRC001-CN-1 ❑ MAC-334IF-E ❑ PAC-WHS01UP-E ❑ PAC-USWHS002-WF-2 ❑ M21 EAA307 Remote Sensor Wireless temperature and humidity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert ❑ PAR-40MAAU Simple Ductless Wired Remote Controller ❑ PAC-SDW01 RC-1 Wired Remote Controller Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch' RedLINK'° Wireless Controller ❑ MHK2 Wireless Remote Controller Lockdown bracket for remote controller ❑ RCMKP1CB Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor ❑ X87-835 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Blue Diamond MultiTank— collection tank for use with multiple pumps ❑ C21-014 Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Sauermann Condensate Pump ❑ S130-230 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Anti -allergy Enzyme Filter ❑ MAC-408FT-E Filter Microparticle (PM2.5) Filter ❑ MAC-EMF515FT-E NOTES: $PAC-SF40RM-E (Unable to use with wireless remote controller) Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Lineset Mounting Pad Stand 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) Condensing Unit Mounting Pad: 24" x 42" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket - Stainless Steel Finish Outdoor Unit Stand —12" High ❑ MLS143812T-15 ❑ MLS143812T-30 ❑ MLS143812T-50 ❑ MLS143812T-65 ❑ ULTRILITE2 ❑ DSD-400P ❑ QSMS1801M ❑ QSMS2401M ❑ QSWBSS ❑ QSMS1201M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. t VL. !!...■Ell 9-I/8 3/16 Indoor u 1-3/4 1-15/16 u 24-3/8 1.5-1/8J 2-3/� II • \ • e � M 2-3/16 IS/16 I-3/16 Wireless remote controller Unit: inch Air Insulation o1 - 9/16 O.D c Liquid line o1/4 19 - 11/16 (Flared connection o1/4) a Gas line o3/8 16 - 15/16 (Flared connection: o3/8 (GSO6/09/12NA), o1/2 (GS15NA)) Drain hose Insulation o1-1/8 O.D Connected part o5/8 O.D Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch REQUIRED SPACE *1 4 in. or more when front and sides of the unit are clear a) ore 6 shore III AIM Air in Drain hole 01-21/32 (09/12/15 Btu/h) e Air in 0 ...... 01- 11101-e C3 e A 00.9; *2 When any 2 sides of left, right 1-9/16 � and rear of the unit are clear Air out 2-holes 3/8X13/16 FORM# MSZ-GS15NA& MUZ-GS15NAHZ - 202306 Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint �Ili Refrigerant pipe (flared) o 3/8 (09/12 KBTU/H) Lnj I IIIIIIIl ',KV 11 1 o 1/2 (15 KBTU/H) 6MEVA91PA 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com 0%. " s Intertek Specifications are subject to change without notice. @ 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.