FIR2025-0022_Fire_Alarm_Equipment_Specification_Sheets_3.7.2025_10.01.30_AM_4798143.. EXISTING FIRE ALARM CONTROL PANEL 5 "4,,A tA NAPCO OPERATING GUIDE MAGNUM FIRE ALERTTm 6000-SERIES FIRE ALARM CONTROL PANEL CONGRATULATIONS! on your purchase of a NAPCO fire alarm control panel. Your MAGNUM FIRE ALERT system has the comprehensive features and ease of opera- tion consistent with NAPGO's reputation for quality and value. Your new installation is a highly -sophisticated warning system with many available features. Your dealer will explain your system and show you how it works. Contact him should questions concerning system operation arise. This booklet contains important information concerning the operation of this system. There is a section of this pamphlet that covers the limitations of this system. Such limitations pertain to all fire alarm warning systems. Please read it carefully and keep it handy for future reference. Please be sure to complete and return the enclosed Warranty Registration Card promptly. 0 NAPCO 1987 NEW WIRELESSICOMMUNICATOR ES CORPORATION 7707 Fire Subscribers IntelliNet Feature Highlights • Offers flexible power and configuration options. Engineered for backward compatibility with legacy systems. Enables future ready capabilities. • Provides instant Subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button. Includes dual communication/multiple communication technology (reporting over RF and Im ❑8 v Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets, and PCs. Key Benefits Built upon the solid foundation of AES-IntelliNet° patented mesh radio technology for use in private licensed wireless networks. • Protects Subscriber units against unauthorized access and rogue activity with a password protected Dealer Code. • Makes programming and streamlined troubleshooting easy with user friendly interface. Adds integrated supervision of 7794A AES-IntelliPro full data module. • Provides versatile power options. Models l-- 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8-Zone with Multiple Communication Technologies (MCT), Red Enclosure i IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with 7707P 44 M Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-U LP-M with 7794A AES-IntelliPro and Integrated oOnboard Local Annunciator, plus Multiple Communication Technologies MCT, Red Enclosure Technical Specifications DIMENSIONS 13"H x 8.5"W x 4.5"D (33cm H x 21.5cm W x 11.4cm D) WEIGHT • 15.85 Ibs (7.2 kilograms) with 12Ah battery • 7 Ibs (3.2 kilograms) excluding battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB Tamper resistant antenna included POWER INPUT • 16.5V AC Class 2 Transformer Transformer not included • 24V DC External Regulated Power Supply • 24V DC Regulated Power Supply from FACP AUX Power ALARM SIGNAL INPUTS/ ZONES • 8 Individually programmable E.O.L. type zone inputs • 4x4 Option with 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs • Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile, and Modem Illa2 UL LISTINGS • UL 864 Standard for Control Units and Accessories for Fire Alarm Systems, Edition 10 • ULC 5559-04 Equipment for Fire Signal Receiving Centers and Systems, Edition 1 TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non -condensing PORTS • (1) Ethernet • (2) USBs ANNUNCIATOR Integrated Local Annunciator PROGRAMMING INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC POWER OUTPUT 2 or 5 Watts Contact AES for other options ENCLOSURE MATERIAL Metal with paint finish FINISH COLOR Red VISUAL INDICATORS • Front panel LCD (2 x 20 alphanumeric character backlit display) • Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) • Menu/ Silence button BATTERY CALCULATIONS 1) Select the AES model from the AES Model field. 2) Select if Intellipro is installed 3) Select if Ethernet Cable is installed during normal operation. (Only applies to 2.0 subscribers) 4) Select if 7762 is installed (Only applies to 7788F) 5) Enter the # of hours of backup time required. AES products are UL listed for 24 hours operation on battery backup. 6) The calculator will return the recommended minumum battery capacity and max primary input DC and AC current BACKUP BATTERY CALCULATIONS AES Model 7794A Ipro Ethernet Cable # Hours Backup Installed Installed Time 7177 Yes Yes No 24 Standby Current (Amps) Intellipro Current (Amps) Ethernet Current (Amps) 7762 Current (Amps) Total Standby Current (Amps) 0.175 + 0.165 + 0.015 + 0.000 = 0.355 # Hours Backup Standby Current Required Standby Time (Amps) Capacity (Amp -Hours) 24 x 0.355 = 8.52 Transmit/Alarm Required Alarm Required Alarm Current (Amps) Time (Hours) Capacity (Amp -Hours) 0.786 x 0.25 = 0.20 Required Standby Required Alarm Total Required Capacity Capacity Backup Capacity (Amp -Hours) (Amp -Hours) (Amp -Hours) 8.52 + 0.20 = 8.72 Total Required Recommended Backup Capacity *Recommended Minimum Battery (Amp -Hours) Safety Factor Capacity (Amp -Hours) *** 8.72 x 125% = 10.9 *** The battery requirements presented here are only AES recommendations. NEW WIRELESS COMMUNICATOR 6 COMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FS can augment or replace legacy Telco lines with reliable cellular signal reporting. AHJs know that the TG-7FS meets all UL and ULC standards, and works in virtually every installation. PRODUCT FEATURES f Powers directly from a 12 or 24VDC alarm panel — no electrician needed for an outlet. Or, for AC, use included plug-in adapter. F Operates on LTE-M networks, for 5G longevity, lower power consumption, and better in -building penetration. Interfaces with fire panels using a single DACT connection for universal compatibility. No DACT is no problem — just add a TG-PEM accessory to the TG-7FS. f American made, and backed by award -winning, U.S.-based tech support. This is the communicator dealers have loved for over a decade, updated with a more modern 5G LTE-M cellular radio, more efficient use of power, and more options. You're in control when setting up and installing the TG-7FS. Apply desired settings when you're in the office or on the road using the Telguard online dealer portal. Signals can be reported to your central station of choice. For the most current product specifications and UL Listings visit telguard.com/tg-7fs. In Canada, cellular data may be carried by Rogers, Bell, Telus or SaskTel. CHOOSE THE COMMUNICATOR THAT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. TG-7UB �I 800.229.2326 13225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA I telguard.com ©2021 Telguard I Telguard and the Telguard Logo are registered trademarks of Telular Corporation. I Telular is a business unit of AMETEK, Inc. All Rights Reserved. MWETEK BATTERY CALCULATIONS T E L G U A R D AMETEK` Device Status Time Frame Idle with Link Supervision 24 Hours (1440 minutes) Alarm Transmitting Mode 5 Minutes Subtotal: Add 25% for battery depletion: Battery Calculation Estimate: TG-7FS TG-7FS + TG-PEM J w Current Draw Current Draw Idle: 42mA Idle: 46mA Transmit:110mA Transmit:132mA Consumption (AH) Consumption (AH) 1,008mAH 1,104mAH 10mAH 11mAH 1,018mAH 1,11SmAH 255mAH 279mAH 1,273mAH 1,394mAH