APVD BLD BLD2025-0188+Structural_Plan+2.7.2025_8.43.07_AM+4750753ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE GENERAL ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION. SPECIFICATIONS AND STANDARDS MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. DESIGN LOADS CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION DEAD LOADS: OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. ROOF 13 PSF CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL LIVE LOADS: PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. ROOF (SNOW LOAD) 25 PSF CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL FOUNDATIONS: SPREAD FOOTINGS ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. SOILS REPORT: NOT AVAILABLE AT TIME OF DESIGN ALLOWABLE SOIL PRESSURE LATERAL EARTH PRESSURE: UNRESTRAINED: RESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 1500 PSF (ASSUMED) 35 PCF + ANY APPLICABLE SURCHARGE 50 PCF + ANY APPLICABLE SURCHARGE 300 PCF 0.35 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.2 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL GLUE -LAMINATED TIMBER GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE FOLLOWING MINIMUM STANDARDS: SPAN COMBINATION Fb SIMPLE SPAN BEAMS 24F-V4 2400 PSI EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. 1 WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO j 1 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. 1 1 REFER TO 2021 IRC R314 AND R315 FOR MORE 1 INFORMATION. i DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF FRAMING 1W I NATIVE SOIL iImImImImIr EXTENT OF FRAMING GRANULAR FILL COLUMNS STRUCTURAL STEEL COLUMN BEARING ON BEAM RATED SHEATHING P BEAM CONTINUOUS OVER SUPPORT SHEAR WALL SWX (SEE SCHEDULE) 0 CONCRETE WALL COLUMN MARK G� (SEE SCHEDULE) BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING HOLDOWN MARK STUD WALL (SEE SCHEDULE) HANGER MARK OX BEARING STUD SHEAR WALL (SEE SCHEDULE) FLAG NOTE NON -BEARING STUD SHEAR WALL (SEE PLAN NOTES) CMU WALL STEEL MOMENT FRAME CONN. ABBREVIATIONS (A) ABOVE AB ANCHOR BOLT ALT ALTERNATE ARCH ARCHITECT (B) BELOW HORIZ HORIZONTAL KP KING POST KSI MECH KIPS PER SQUARE INCH MECHANICAL MF MOMENT FRAME BLKG BLOCKING BEAM BOTTOM BETWEEN COMPLETE JOINT PENETRATION CLEAR NS OC NEAR SIDE BM ON CENTER BOT OPP OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH BTWN PL CJP PLCS PSI CLR CMU CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION PSF POUNDS PER SQUARE FOOT COL P/T POSTTENSIONED CONC PT PRESSURE TREATED CONN REINF REINFORCING CONT CONTINUOUS REQ'D REQUIRED DBL DOUBLE DET DETAIL SCHED SIM SCHEDULE SIMILAR DIM DIMENSION EACH SOG SLAB ON GRADE EA STD STANDARD ELEV ELEVATION SW TOC SHEAR WALL TOP OF CONCRETE EXIST EXISTING EXP EXPANSION TOS TOW TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE FLR FLOOR FDN FOUNDATION FOOTING FAR SIDE FULL HEIGHT GLUE -LAMINATED BEAM TYP LINO FTG FS VFY VIF VERIFY FH VERIFY IN FIELD GLB VERT VERTICAL City Of Edmonds Building Department Work ADD BEAM - REMOVE WALL Address 1026 WALNUT Owner STEELE Approved Date 2/14/2025 ----------------------- s-------- Building Official Permit Number BLD2025-0188 RECEIVED Feb 07 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 01/ 11/ 25 Y Q DESIGN: ZSH DRAWN: JCP CHECK: DMT JOB NO: 24443.10 DATE: 01 / 1 7/25 La w 0 w a� N Z 0 00 w rn D Q V) Z w J CY-Q V) �C1 w Z 0 w N :2 I— 0 0 V) T­ w SHEET: Simi V / w F_ 0 Z LL ZD U D V) ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 v O v N N N W Ll W of wasp �G v~i v~i N w w o IF I > VJP 45L'� sSI0 01/ 17/ 25 WALL TO BE REMOVED EXIST TRUSSES I I EXIST TRUSSES J @ 24" OC ml I @ 24" OC Q � I I ~ _I ~ 2 0 m x N 0m U m W Lu 0 d Ln W 4x6 HF#2 W/ ECCQ Q COLUMN CAP & ABW C BASE W/ 1/2"0 TITEN HD SCREW ANCHOR, TYP Y 2x4 BLOCKING W/ 8d FULL DEPTH BLOCKING TO Q NAILS @ 6" OC MATCH SLOPE OF ROOF DESIGN: ZSH DRAWN: JCP CHECK: DMT EXIST TRUSSES JOB NO: 24443.10 @ 24" OC DATE: 01 / 1 7/25 EXIST ROOF TRUSS �+ PER PLAN, TYP 16d NAILS @ 6" OC SIMPSON H2.5A Q TIE AT EA TRUSS BEAM PER PLAN W ROOF FRAMING PLAN SECTION 0 1 SCALE: 1/4" = V-0" Q TYPICAL ROOF FRAMING PLAN NOTES: 2'-0" 0 2'-0" 4'-0' 16 Z 1. COLUMNS AND BEARING WALLS SHOWN ON PLANS SHALL BE CONTINUED DOWN TO THE FOUNDATION. Q 2. WALLS SHOWN ON THE FRAMING PLANS ARE WALLS BELOW THE FRAMING LEVELS INDICATED. Ld Q w O w a� N Z (n 00 Z w O) D Q Q w J cy- Q V) LL. 0 w Z LL. Woo 0 w N :2 0 w V) o o SHEET: S2ml