REVIEWED BLD2023-0640+Energy_Calculations+5.23.2023_2.08.21_PM+3564456BLD2023-0640 RECEIVED I I n 7 Simple heating System Size: wasnington State Wu� This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA CITY Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling IODMELO Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. _023 AONDS SERVICES ENT Project Information Contact Information :..........................................•••• REVIEWED Michael Koh Beng Chye & Yvette Sylvia Ann Xavier Nazim Nice BY 15604 75th PI W, Edmonds, WA 98026 13104 Western Ave, #107, Seattle, WA 98121 CITY OF EDMONDS 616-634-1293, michael.yvette@gmail.com 206-204-0490, nazim@motion-space.com € ........BUILDING DEPARTMENT: Heating System Type: O All Other Systems O Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT=Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,690 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 13.8 50,922 Glazing and Doors U-Factor X Area = UA Instructions 0.280 1,636 458.08 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instructions R 49 I 0.026 J 56 1.46 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-49Advanced I 0.020 J F 3,634 72.68 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Intermediate I 0.056 l 2,113 118.33 Floors U-Factor X Area UA Instructions � I 0.025 3,690 92.25 R-38 1 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. I 0.028 00 Slab Below Grade see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this 0.303 I 0� --- project. Slab on Grade (see Fi ure 1) F-Factor X Length UA Instructions R-10 Fully Insulated � I 0.360 J 213 76.68 Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 819.47 Figure 1. Above Grade 46 Envelope Heat Load 37,696 Btu / Hour Sum of UA x AT Air Leakage Heat Load 25,298 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 62,994 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 62,994 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 78,742 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07101113)