APPROVED PLN BLD BLD2025-0016+ARCH PLANS+1.6.2025_12.28.09_PM+469773817521 72nd Ave W Residence APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE Provide the special inspection report to the building inspector S241 101-IXR PROJECT INFORMATION CLIENT BRETT BELL 17521 72nd Ave W Edmonds, WA 98026 PROJECT ADDRESS 17521 72nd Ave W Edmonds, WA 98026 STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN 13150 91ST PL NE KIRKLAND, WA 98034 CONTACT: MANS THURFJELL, PE PHONE: (425)-636-3313 EMAIL: MTHURFJELL@Ll20ENGINEERING.COM CODES ENGINEERED PER: 2021 (IRC) INTERNATIONAL RESIDENTIAL CODE 2021 (IBC) INTERNATIONAL BUILDING CODE SHEET INDEX COVER SHEET .... S-0 STRUCTURAL GENERAL NOTES .... S-1 SITE & FOUNDATION PLAN .... S-2 FOUNDATION DETAILS .... SD-1.1 City Of Edmonds Building Department Work FOUNDATION STABILIZATION Address 17521 72ND AVE W Owner BELL ------------------ ------------------------------------------- Approved Date' 01/23/2025 ------------------------------------- Building Official Les K.resteL ----------------- Permit Number,BLD2025-0016 ----------------- SR. T HURL •• •� • �> fit• �y- • •. NA I. E�•' • ■ ■ oil • W C > (3 z o � W .6 _ > z ,R > _Z w z W z z Z O 0 w J REVISIONS 0 DESCRIPTION DATE BY BLD2025-0016 RECEIVED Jan 06 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NAME 17521 72nd Ave W Edmonds, WA 98026 PROJECT NUMBER S241101-1 XR DRAWN , I PAM CHECKED BY - M RT SHEET DATE 12/23/2024 SC) z o O i DC (n V W > w 0 O w ULU GENERAL STRUCTURAL NOTES HELICAL PILES DESIGN CRITERIA 1 CODE: 2021 IBC/IRC & AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY ROOF ........................................25 PSF SNOW (GROUND) 2 FLOORS RESIDENTIAL .....................40 PSF 3 BALCONY/DECK................60 PSF 4 GENERAL CONDITIONS 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL 5. ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY 6 DISCREPANCIES. 7. 3. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL 8 BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 9 4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE "GENERAL NOTES" AND/OR "STANDARD DETAILS". 5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE 10 SAME AS FOR SIMILAR WORK. 6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY 11 CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE DISTRESS TO THE STRUCTURE. 12 8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE 13 ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. 9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE 14 INTERNATIONAL BUILDING CODE, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK. 15 10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. 12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. 13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION. 14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE "INTERNATIONAL BUILDING CODE" (IBC), AND STANDARDS REFERENCED THEREIN. 15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES EXCAVATIONS, COLUMNS, EQUIPMENT LOADS, MATERIAL LOADS, AND OTHERS. OBSERVATIONS BY THE ENGINEER -OF -RECORD DO NOT INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. 16 16. PILE AND SOILS PARAMETERS PER GEOTECHNICAL REPORT DATED DECEMBER 18TH, 2024 BY COBALT GEOSCIENCES. ESTIMATED DEPTH TO END BEARING REFUSAL ............. 5'-0" to 10'-0" CONCRETEANCHORS 1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE, HILTI, OR EQUIVALENT. SPECIAL INSPECTIONS REQUIRED. STRUCTURAL AND MISC. STEEL 1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 2. MATERIALS: BOLTS - ASTM A307, UNLESS OTHERWISE NOTED WF BEAMS - ASTM A572-50 (Fy = 50,000 PSI) HSS ROUND COLUMNS - ASTM A500 Gr. B (Fy = 42,000 PSI) HSS RECTANGULAR COLUMNS - ASTM A500 Gr. B (Fy = 46,000 PSI) ALL OTHER STEEL - ASTM A36 (Fy = 36,000 PSI) STRUCTURAL STEEL WELDING 1. CONFORM TO THE AWS CODES D1.1 AND D1.3., AND USE ONLY CERTIFIED WELDERS. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. Fill! a111d!]1Fit 01� 1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST PAYMENT FOR REVIEW; CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL COST TO OWNER. JOBSITE SAFETY: 1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM HIS WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR, SUBCONTRACTORS, SUPPLIERS OR THEIR EMPLOYEES, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY ANY PERSON. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2021 INTERNATIONAL BUILDING CODE (IBC). HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING, INC., AND SHALL BE IN ACCORDANCE WITH ESR-5049 OR 3750 FOR TIEBACKS. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-5049. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF +/-1 DEGREE FROM VERTICAL PER ESR-5049. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O21 AND 2018 IBC SECTION 1705.9 MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: A. PRODUCT MANUFACTURER B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT USED, AND THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS E. ANTICIPATED AND ACTUAL PILING DEPTH F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. HELICAL PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2021 INTERNATIONAL BUILDING CODE (IBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. ABBREVIATIONS AB ANCHOR BOLT FTG FOOTING ABV ABOVE GA GAUGE AFF ABOVE FINISH FLOOR GALV GALVANIZED ALT ALTERNATE GLB GLULAM BEAM ALUM ALUMINUM GR GRADE APPROX APPROXIMATE GYP GYPSUM WALL BOARD AYC ALASKAN YELLOW CEDAR HDG HOT -DIPPED GALVANIZED BB BOX BEAM HDR HEADER BF BOTTOM FLUSH HF HEM FIR BLDG BUILDING HGT HEIGHT BLKG BLOCKING HT HEIGHT BM BEAM IN INCH BOT BOTTOM IT JOINT BP BOTTOM PLATE MAX MAXIMUM BRIG BEARING MIN MINIMUM BTWN BETWEEN MISC MISCELLANEOUS BSMT BASEMENT NB NON -BEARING B/W BOTTOM OF WALL NO NUMBER CANT CANTILEVER OC ON CENTER CJ CONTROL JOINT PSF POUNDS PER SQUARE FOOT CLG. CEILING PSI POUNDS PER SQUARE INCH CLI CEILING JOIST PT PRESSURE TREATED CLR CLEAR CMU CONCRETE MASONRY UNIT RAF RAFTER COL COLUMN REF REFERENCE CONC CONCRETE REINF REINFORCEMENT CONN CONNECTION REQD REQUIRED CONST CONSTRUCTION SF SQUARE FOOT CONT CONTINUOUS SIM SIMILAR CTR CENTER SPF SPRUCE PINE FIR DET DETAIL STD STANDARD DF DOUGLAS FIR (SOUTH) SYP SOUTHERN YELLOW PINE DFL DOUGLAS FIR LARCH T/ TOP OF DIM DIMENSION T/C TOP OF CONCRETE DJ DOUBLE JOIST T/P TOP OF PLATE DIA DIAMETER T/S TOP OF STEEL DN DOWN T/W TOP OF WALL DS DOWN SPOUT TF TOP FLUSH EA EACH TJ TRIPLE JOIST EF EACH FACE T/BM TOP OF BEAM EJ EXPANSION JOINT ELEV ELEVATION T/SLABTOP OF SLAB EN EDGE NAILING (PANEL) TP TOP PLATE EQ EQUAL TYP TYPICAL ES EACH SIDE UNO UNLESS NOTED OTHERWISE EW EACH WAY UPA UNDER POST ABOVE FB FLUSH BEAM UWA UNDER WALL ABOVE FIN FINISH VERT VERTICAL FL FLOOR VIF VERIFY IN FIELD FLSHG FLASHING W/ WITH FND FOUNDATION WC WESTERN CEDAR FP FIREPLACE WP WATERPROOF FT FOOT WWF WELDED WIRE FABRIC SPECIAL INSPECTIONS SCHEDULE SPECIAL INSPECTIONS TABLES PER THE 2018 IBC. ALL ITEMS NON -APPLICABLE ITEMS HAVE BEEN MARKED WITH A "-". ITEMS REQUIRING SPECIAL INSPECTION HAVE BEEN MARKED WITH AN "X". TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION CONTINUOUS PERIODIC SPECIAL REFERENCED IBC TYPE SPECIAL INSPECTION INSPECTION " STANDARD REFERENCE 1 Inspect reinforcement including prestressing ACI 318 Ch 20 25 2 tendons and verify placement - 25 3 26 5 1-26 5 3 cip_ 2 Reinforcing bar welding a Verity weldability of reinforcing bars other than AS-rM A 706, AWS D1 4 b. Inspect single -pass fillet welds maximum ACI 318 26 5 4 s/ --and 16 c Inspect all other welds 3 Inspect anchors cast in concrete - - ACI 318 17 8 2 - 4 Inspect anchors post -installed in hardened concrete members a Adhesive anchors installed in horizontally or upwardly inclined orientations to resist - - ACI 318 17-8-2 4 sustained tension loads b Idechanical anchors and adhesive anchors not defined in 4 a 5 Verity use of required design mix ACI 318 Ch- 19, 1904 1 1904 2 2643.2644 190821908' 6 Prior to concrete placement fabricate specimens ASTM C 172 for strength tests perform slump and air - ASTM C 31 1908 10 content tests and determine the temperature of ACI 318 26 4 5, 26 12 the concrete 7 Inspect concrete and shotcrete placement for ACI 318 26 4 5 1908 6 1908 7, proper a lication techniques 19088 8 Verity maintenance of specified curing - - ACI 318 26 4 7-26 4 9 19089 temperature and techniques 9 Inspect prestressed concrete for a Application of prestressing forces and - ACI 318 26 9 2 1 - b Grouting of bonded prestressing tendons - - ACI 318- 26 9 2-3 10 Inspect erection of precast concrete members - ACI 318 Ch 26 8 11 Verify in -situ concrete strength prior to stressing of tendons in post -tensioned concrete and - - ACI 318 26 10 2 prior to removal of shores and forms from beams and structural slabs 12 Inspect formwork for shape location and dimensions of the concrete member being - ACI 318: 26.10.1(b) formed TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1 Verify element materials sizes and lengths comply with the requirements - 2 Determine capacities of test elements and conduct - additional load tests as required 3 Inspect driving operations and maintain complete and _ accurate records for each element 4 Verify placement locations and plumbness confirm type and size of hammer, record number of blows per foot of penetration determine required penetrations to - achieve design capacity record tip and butt elevations and document any dama a to foundation element 5 For steel elements perform additional special inspections in accordance with Section "0.`_, -j 6 For concrete elements and concrete -filled elements. perform tests and additional special inspections in - - accordance with Section 1705 3. 7 For specialty elements perform additional inspections as determined by the registered design professional in - responsible charge ,• �.TH(! F ASHR ✓ '. �-10 . ♦ F � I�•t���T '• NA�•' 0 W z o W .6 _ > Z LU LU Z W z Zz O 10 w REVISIONS 0 DESCRIPTION DATE BY BLD2025-0016 RECEIVED Jan 06 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ---SECT NAME 17521 72nd Ave W Edmonds, WA 98026 PROJECT NUMBER S241101-1 XR DRAWN , I PAM CHECKED BY - M RT SHEET DATE 12/23/2024 SC U) LU z L.L D U D (10 O � U) LU V z I LU Ur W w APPROVED BY PLANNING -''' ` • ♦ �'' ` Feb 06 2025 --•'�' •` SITE PLAN NOTES - - � - - •` 1. VERIFY EXISTING STRUCTURES AND ALL DIMENSIONS ON SITE. • 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL • PER R&R FOUNDATION SPECIALIST (R&R) LEVEL SURVEY. • 3. REFER TO STRUCTURAL CALCULATIONS PACKAGE BY L120 DATED DEC 23, • 2024, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND R�� LNN� .1'' 25'-0" * 18'-0" * REQUIREMENTS. ''' `. 4. LEVEL SURVEY PER R&R PROPOSAL DATED OCT 26, 2024. REFER TO QROP�. - -' �41\ `• STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND �. �'' - x• ADDITIONAL REQUIREMENTS FOR LEVEL SURVEY. �. �' �• 5. PARCEL DIMENSIONS APPROXIMATED BY SNOHOMISH COUNTY ASSESSOR ' GIs MAPPING TOOLS & TAXSIFTER INCLUDING THE SELECTED PARCEL. �'' * \ PROPERTY DIMENSIONS ARE APPROXIMATE FOR REPRESENTATIVE • - -''' ♦ ADDITION C •\• PURPOSES ONLY. NOT TO SCALE. NOT TO BE USED FOR LEGAL PURPOSES -' � \ OR IN PLACE OF A FIELD SURVEY. - - •\ 6. SITE FEATURES AND SOME EXISTING STRUCTURES ON ADJACENT PARCELS - • -'' •� NOT SHOWN FOR CLARITY. - - •� 7. GEOTECH SPECIAL INSPECTOR SHALL BE CONTINUOUSLY PRESENT DURING - - � o' ♦ 1 j•�• = HELICAL PILE INSTALLATION AND TESTING. � - ' - �-0 '- S•`* •� (3) PILES CENTERED ON SUPPORT °0�� O..• `• � � `• � 1 2 3 � •� (E) RESIDENCE • 17521 72nd Ave W o -' " \\ `• ` Edmonds, WA 98026 "' t -' \ • `•� � ` \ ` \ • 4 5 6 • • \• (3) PILES CENTERED ON SUPPORT \• (E) STRUCTURE \• � DETTACHED GARAGE `� \% • SITE PLAN LEGEND \ • • EXISTING RESIDENCE STRUCTURE ...:•;::: * .....:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::... � ::::::......:.:.:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::......::::::::::::::::. \ 11 :.. ...:.:::::.. - - I , r................................................................................................................. I I EXI TIN AD A ENT TR T RE :::.. I S G J C S UC U :::::::: --- :::ca:::: • --- I \ I I I I AREA OF PROPOSED WORK I - I I • • 2 I • �' o PROPERTY LINE o- 0 .::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::..::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::.. APPROXIMATE DIMENSION .........................................................................................................................................................................:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::.. o- HELICAL PILE 1 .::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::.. ..................... ....................................................................................................................................................................... :::::::::::::::::: :::......:::::::::::::::::::::::::::::::......::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::......::::::::::::. ................ � :•::::::::•::::....:::::::::::::::::::::::::::::::::::::::::::::......::::::::::::::::::::::::::::::::::::::::::::::::::::::......::::::::::::::::::::::::::::::::::::::::::......::::::: • .............. .� E R V N 0 P E - ::::: ...::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: . P R ..:::::::.:::::::::::::::::::::::::::::::::::::::::::::::::::::... .0 ....:....::::::::}.::::::::::::::::::::::::::::::::::::::::::......::. - 1 :....: �4 ?t............. ♦ -♦- -' i ' • ' 00 • -�i ♦i' �� • ''' -' • ♦� .- `. ♦ 00 NOTES: 2�, - � - - ♦ a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE � �— - MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING A SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM INSTALLATION TORQUE RATING OF 6,843FT*LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.217 INCH SHAFT WALL THICKNESS PER ESR-5049. b. HELICAL ASSEMBLIES AS MANUFACTURED BY PRECISION PIERS, INC., IN ACCORDANCE WITH ESR-5049. c. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY. d. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. PILE SPACING & LOAD REQUIRMENTS TABLE MIN O.C. SPACING. R MIN VERTICAL CAPACITY. kips PROOF TESTING LOAD. kips PILE » PILE TYPE BTWN PILES END OFFSET ALLOWABLE LOADING 200% MIN VERTICAL CAPACITY LOCATION (MIN ULTIMATE CAPACITY) • - 8 0 kip 16 0 kip INTERIOR LEGAL DESCRIPTION Section 08 Township 27 Range 04 MEADOWDALE BEACH BLK 000 D-03 - S 91 FT OF N 182FT OF S 302FT OF W 148FT OF TR 143 EXC W 1 OFT THOF TO CITY OF ED PER AUD FILE NO 7702180265 1079/685 - AKA LOT B ASDELINEATED ON SKETCH CITY ED SP NO S-46-76 REC AFN 8004020198 TGW VAC W 1OFT BEING A PTN OF 72ND AVE W ORD NO 2257 AF NO 8201260100 VOL 1736 PG 141 OWNER NAME & ADDRESS BELL BRETT T/DIANA L 17521 72nd Ave W Edmonds, WA 98026 R&R LEVEL SURVEY SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS SITE PLAN NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. NOTE: L120'S SCOPE IS LIMITED TO THE PERIMETER SUPPORT SYSTEMICONTINUOUS FOOTINGS. THE INTERIOR CRAWL SPACE SUPPORTED SYSTEM FOR THE FIRST FLOOR SHALL BE INSTALLED PER R&R. • 0 5 S a f * 1S ' T HU'y . "� "� *F4., ✓ �- f Z� .� s:r„r F� . a� < . o �. • � q, �� . . F r �. �� . �.� �QNALE �• ....• ui po z U) z 0 . W .6 z r� w V � Zwz z z O Q w J 1� REVISIONS 0 DESCRIPTION DATE BY BLD2025-0016 RECEIVED Jan 06 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NAME 17521 72nd Ave W Edmonds WA 98026 PROJECT NUMBER S241101-1 XR DRAWN Bl PAM CHECKED BY - M RT SHEET DATE 12/23/2024 SU Z RI Q N a- 0- I u w o w w = Ln II II II �- (.D uj CQ O O LL I I I I I (E) SUPPORT I (E) CONCRETE FOOTING I d d ° T/SOIL = FIELD VERIFY 1111-IIII-IIII-IIII Hill 111-1111=1 PRECISION PIERS H E L I CAL PILE & REPAIR BRACKET ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-5049 NOTES: 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123. 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT CORROSION. HELICAL PILE INSTALLATION DETAIL 2 NOT USED 3 NOT USED 4 NOT USED 5 NOT USED 6 NOT USED SR' T NUR •• •' '. • '•• NA1., , ■ ■ a • W 0 0 z ZLU o W z o w z W z Z(D w O 0 z REVISIONS Q DESCRIPTION DATE BY BLD2025-0016 RECEIVED Jan 06 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NAME 17521 72nd Ave W Edmonds, WA 98026 PROJECT NUMBER S241101-1 XR DRAWL �,, PAM CHECKED BY - M RT SHEET DATE 12/23/2024 SCl J Q Lu 0 z 0 I o Q 0 0 U) z V U) w 0 w ILL Lu U)