APVD BLD PLN BLD2025-0135+Architectural_Plan+1.28.2025_10.08.13_PM+4734549Smoke detectors —
PROVIDE CO
DETECTOR OUTSITDE
OF SLEEPING AREAS
Bathroom
APPROVED
PLANS MUST BE
ON JOB SITE
City Of Edmonds
Building Department
Work —COD" REMODEL
Address 18730 94TH AVE W
Owner SMILEY
Approved Date --- 2/14/2025
Building Official V%4U�GL
Permit Number BLD2025-0135
Current basement layout (No layout change)
101811
Oo
u
o �
0 5'
r
13' 6"
19' 4"
STY
o
WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1
TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO
DETECTORS THROUGHOUT THE DWELLING IS REQUIRED.
1 1
REFER TO 2021 IRC R314 AND R315 FOR MORE 1
INFORMATION.
1
32"x12" mini split wall unit
6000 Btu
724"x24" mini split ceiling cassette
12000 btu
32"xl2" mini split wall unit
6000 Btu
32"x12" mini split wall unit
6000 Btu
2 40 gallon Water heaters under stairs (existing)
Exhaust fan, 80/110 cfm
Furnace (existing)
ALL WORK SUBJECT 32"x12" mini split wall unit
TO FIELD
INSPECTION FOR 6000 Btu; --------------------------------------- ---------------------------------------
i
CODE COMPLIANCE OBTAIN A SEPARATE ? OBTAIN ELECTRICAL
PLUMBING PERMIT PERMIT FROM
FROM THE CITY OF STATE LABOR &
...... EDMONDS. INDUSTRIES
1 '
1 STRUCTURAL REPAIR IS NOT INCLUDED IN THE SCOPE FOR THIS PERMIT. ....................................... ....................................•
IF IT IS FOUND THAT STRUCTURAL REPAIRS ARE NEEDED A SEPARATE 1
1 PERMIT MUST BE SUBMITTED TO THE CITY FOR APPROVAL, AND PLANS
MUST BE STAMPED AND SIGNED BY THE ENGINEER OF RECORD. 1
1
SMILEY
REMODEL
18730 94TH AVE W
PAGE 1
Current main floor layout
This wall is staying
Demo, non -load
Moving up 35, non- load
Master bed III I Living room
C� C)
FV
CCUdo
C)
v
®IO REF N
Kitchen
Bedroom nII
Office
Garage
p2
ump 1
Main entrance
SMILEY
REMODEL
18730 94TH AVE W
PAGE 2
5'11"
■
T
v cc
33
0
3 ce
0
T
co
z Storage
Master bedroom
N
0
Garage
Heatpump2
New main floor layout
Living room
PROVIDE CO
DETECTOR OUTSITDE
OF SLEEPING AREAS
24"x24" mini split ceiling sette
WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1
207-335 cfm, 12000 btu ' TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO
DETECTORS THROUGHOUT THE DWELLING IS REQUIRED.
1
REFER TO 2021 IRC R314 AND R315 FOR MORE 1
^� -INFORMATION.
- J� 1
-.
7
®L7eL
0 C� � 24"x24" mini split ceiling cassette
, 207-335 cfm, 24000 btu
KCabinets
Main entrance CO detector
)ke detector
Exhaust fan, 80/110 cfm
Blue walls=New
PROVIDE AND
SMOKE DETECTOR
OUTSITDE OF
Heatpump 1 SLEEPING AREAS
1 WHERE EXISTING EXTERIOR WALL CAVATIES ARE EXPOSED 1
DURING CONSTRUCTION, INSULATION MUST MEET THE
REQUIREMENTS OF 2021 WSEC R503.1.1(2): R-15 @ 2X4
WALLS AND R-21 @ 2X6 WALLS.
3271x12" mini split wall unit
134-381 cfm, 6000 btu
SMILEY
REMODEL
18730 94TH AVE W
PAGE 3
Roof framing layout
2x6, 16'long, 16" center
2xT 17' long, 16" center
2x6, 11' long, 16" center
2x6,14' long, 16" center
19' long, 16" center
SMILEY
REMODEL
18730 94TH AVE W
PAGE 4
ION
DOOR UNITS
BE HANGING
WALL.
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application ,regardless
of whether such building, structure or condition is
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate
enforcement action.
Zone RS-12 Corner N Flag N
Setbacks: Required
Actual
Front 25'
ex.
Sides 1W
ex.
Rear 25'
ex.
Other
Height 25'
ex.
knechanical.,opment>36- `I
high as installed must ab,dc by �s I
the setbacks of Title 16 ECDC.
-se g.neratetl by mechanical
equipment must meat th.
standards in ECC 5,30,
APPROVED By PLANNING
4�<y�
162252,
b
- 78� Lot line
I - 6„
Co ,
I
i .
i 1
Living room 1
! 1 421211
I 1
O u
® 1
KitchenCO
Cq
I 1
I ... 1
NI 1
M
I 1
>191 21
! Garage
741 411
I 1
��eatpa p 1
1
1
1
1
1
1
I
I 1'
1
� � 1
� /r1
M
I � /
I /
I /
I /
I /
M
i
1O1i
SMILEY
REMODEL
18730 94TH AVE W
PAGE 5
Mounting bracket
Maxwell Heavy Duty Universal Wall Mount Bracket for Ductless Air Conditioner Outdoor Unit WAFP24-R
Suitable for 24,000 to 48,000 BTU capacity units