Loading...
RVWD BLD BLD2025-0135+_Manufacturer_Specifications_and_Installation_Instructions_01-27-2025_15_43_14_MXZ-5C42NA4 (1)Job Name: System Reference: BLD2025-0135 Date: ............................................ RECEIVED REVIEWED Jan 29 2025 BY CITY OFEDMONDS CITY OF EDMONDS DEVELOPMENTSERVICES DEPARTMENTMENT BUILDING DEPARTMENT :..............................................: FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High-pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time perASTM B117 Standard Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Power Factor (208V, 230V) Maximum Capacity Rated Capacity BTU/H 43,000 // 41,000 // 39,000 41,000 // 39,000 BTU/H 40,500 // 38,950 // 37,400 38,450 // 36,400 BTU/H 12,600 // 12,600 // 12,600 14,850 // 17,100 W 4,775 // 4,683 // 4,590 4,683 // 4,590 W 4,403 // 4,258 // 4,112 14,224 // 4,045 % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 199.0, 99.0 // 99.0, 99.0 Heating at 47°F' (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) BTU/H 53,600 // 52,600 // 51,600147,300 // 41,000 BTU/H 45,000 // 43,000 // 41,000 43,000 // 41,000 Minimum Capacity BTU/H W 11,400 // 11,400 // 11,400 113,850 // 16,300 6,160 // 6,215 // 6,270 16,215 // 6,270 Maximum Power Input Rated Power Input W 3,575 // 3,519 // 3,46314,048 // 4,520 Power Factor (208V, 230V) % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 199.0, 99.0 // 99.0, 99.0 Heating at 17°F3 (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 30,500 // 29,800 // 29,1001 29,800 // 29,100 Rated Capacity BTU/H 24,400 // 23,700 // 23,000123,700 // 23,000 Maximum Power Input W 4,750 // 4,991 // 5,231 14,991 // 5,231 Rated Power Input W 2,943 // 2,906 // 2,8691 3,247 // 3,550 Heating at 5°F4 (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 25,000 // 25,000 // 25,000 25,000 // 25,000 Maximum Power Input W 5,000 // 5,200 H 5,4001 5,200 H 5,400 Efficiency (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) SEER2 19.7 // 17.45 H 15.2 1 17.45 // 15.2 EER2' 9.2H9.1H9.0 9.1//9.0 HSPF2 (IV) 9.2 // 9.1 // 9.0 18.75 // 8.3 COP at 47°F� 3.68 // 3.57 // 3.46 13.17 // 2.66 COP at 17°F at Maximum Capacity3 1.88 H 1.76 H 1.63 11.76 H 1.63 COP at 5°F at Maximum Capacity' 1.47 H 1.42 H 1.36 11.42 H 1.36 ENERGY STAR® Certified No // No H No 1 No H No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 2081230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 40 Recommended Wire Size (Indoor - Outdoor) AWG 14 Minimum Circuit Ampacity A 32.5 Maximum Overcurrent Protection A 40 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,150 12,550 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 56 Sound Pressure Level, Heating2 dB(A) 58 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model MNB33FBTMC Compressor Rated Load Amps A 20 Compressor Locked Rotor Amps A 28.8 Compressor Oil Type H Charge oz. FV50S // 37.2 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 41-17/64 [1,048] Package Dimensions W: In. [mm] 41-3/8 [1,050] D: In. [mm] 17-3/8 [440] H: In. [mm] 48-7/16 [1,230] Unit Weight Lbs.[kg] 189 [86] Package Weight Lbs.[kg] 218 [99] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'") °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.4 / 5 NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according to AHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trans HVAC US LLC. All rights reserved. • I 1 I SPECIFICATIONS: Type Refrigerant R410A Pre -Charged Refrigerant Amount Lbs, oz 8.0, 13.0 Maximum Pre -Charged Piping Length -Ef Ft. [m] 98.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] Indoor unit connection Maximum Number of Connected IDU 5 Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 51,000 Piping Liquid Pipe Size O.D.(Flared) In.[mm] A,B,C,D,E:1/4 [A,B,C,D,E:6.35] Gas Pipe Size O.D. (Flared) In.[mm] A: 112; B,C,D,E: 3/8 [A: 12.72; B,C,D,E: 9.52] Total Piping Length Ft. [m] 262 [80] Maximum Height Difference, ODU above IDU Ft. [m] 49 [15] Maximum Height Difference, ODU below IDU Ft. [m] 49 [15] Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends for IDU 80 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 'A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according to AHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Refrigeration Ball Valve - 1/2" ❑ PAC-SH96SG-E ❑ BV12FFSI2 Refrigeration Ball Valve - 1/4" ❑ BV14FFSI2 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Drain Socket Drain Socket ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-A1 M-NET Converter M-NET Converter ❑ PAC-IF01MNT-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW 164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW 164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ❑ ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD400P Optional Defrost Heater Optional Defrost Heater ❑ PAC-645BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adaptor Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801 M 4" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Rear Air Intake 2-13/16' 9 7/3 ' 2-1/32' 13/32' 3-13 6" 3-1/8' m Side Air Intake* Air Discharge 1.FREE SPACE E o E v E 3-15/16' or more ZZ i p 8 8 3-15/16' or more 13-25/32" or more 2.SERVICE SPACE of v or more 13-25/32 P orE more FORM# MXZ-5C42NA4 - 202311 2-U Shaped Notched Hale (Foundation Bolt 1110) 4 2-(15/32'x1-13/32) Oval Hole (Foundation Bolt 1110) Conduit plate Top Lo ..... Conduit plate Under Unit: inch (mm) 2-3/4' BIAS}Unit E LID }Unit D GASLIO 1/4'(06.35)FLARE GAS}Unit C GAS3/8'(09.52)FLARE GAS�Unit B LIO GAS }Unit A—LIO 1/4'(06.35)FLARE GAS1/2'(012.7 )FLARE nnector 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com a Eta Ds Intertek Specifications are subject to change without notice. O 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.