APPROVED BLD BLD2025-0136+Structural_Analysis_or_Calculations+1.28.2025_6.28.04_PM+4734397CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2021 INTERNATIONAL BUILDING CODE. 2. DESIGN LOADING CRITERIA: EARTHQUAKE ... ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE LATERAL SYSTEM: LIGHT FRAMED WOOD SHEAR WALLS SITE CLASS=D, Ss=1.281, Sds=1.000, S1=0.451, SDI=0.556 Cs=0.154, SDC D, le=1.0, R=6.5 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 4. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-02 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION" 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. ALL TYPICAL AND NOTES SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL SHALL BE USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR SHALL SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION AND FIELD USE. RENOVATION 6. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 7. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 8. CONTRACTOR SHALL CHECK FOR DRYROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. ANCHORAGE 9. EXPANSION BOLTS INTO CONCRETE SHALL BE STRONG BOLT 2 WEDGE ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICC-ES REPORT NUMBER ESR-3037, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. 10. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) INTO CONCRETE SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET-3G" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON STRONG, TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-4057. MINIMUM BASE MATERIAL TEMPERATURE IS 40 DEGREES, F. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDDED BAR TYPE AND DIMENSIONS, LOCATION, ADHESIVE IDENTIFICATION AND EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT, AND ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL AND OVERHEAD INSTALLATIONS. 11. CONCRETE SCREW ANCHORS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE TITEN HD HEAVY DUTY SCREW ANCHOR AS MANUFACTURED BY THE SIMPSON STRONG -TIE CORP., INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2713 (CONCRETE), NO. ESR-1056 (CMU), INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SCREW ANCHORS INTO CONCRETE MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICBO, OR ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. WOOD 12. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: ALL STRUCTURAL WOOD DOUGLAS-FIR-LARCH OR HEM -FIR NO. 2 13. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 14. ALL WOOD INDIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. General Structural Notes THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS 15. PRESSURE TREATED WOOD (INCLUDES PRESERVATIVE AND FIRE TREATED)SHALL BE TREATED PER AWPA STANDARD. PRESSURE TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO RETENTION OF 0.25 PCF. WOOD IN CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO A RETENTION OF 0.40 PCF. WOOD FOR USE IN PERMANENT FOUNDATIONS SHALL BE TREATED TO A RETENTION OF 0.60 PCF. SODIUM BORATE (SBX) TREATED WOOD SHALL NOT BE USED WHERE EXPOSED TO WEATHER. FASTENERS AND TIMBER CONNECTORS WITHOUT AMMONIA IN DIRECT CONTACT WITH ACQ-A (UP TO A RETENTION LEVEL OF 0.40 PCF), CBA-A (UP TO A RETENTION LEVEL OF 0.41 PCF), CA-B (UP TO A RETENTION LEVEL OF 0.21 PCF), OR SBX TREATED WOOD SHALL BE G185 OR A185 HOT DIPPED OR CONTINUOUS HOT -GALVANIZED PER ASTM A653. FASTENERS AND TIMBER CONNECTORS WITH AMMONIA IN DIRECT CONTACT WITH ACQ-A (OVER A RETENTION LEVEL OF 0.40 PCF), CBA-A (OVER A RETENTION LEVEL OF 0.41 PCF), CA-B (OVER A RETENTION LEVEL OF 0.21 PCF), OR WITH ACZA TREATED WOOD SHALL BE TYPE 304 OR 316 STAINLESS STEEL. 16. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-2011. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR MAXIMUM LOAD CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. 17, WOOD FASTENERS A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6d 2" 0.113" 8d 2-112" 0.131" 10d 3" 0.148" 16d 3-1/2" 0.135" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. PARCEL: 27043000205400 LEGAL: SEC 30 TWP 27 RGE 04RT-4-) W 185FT OF N 70FT OF S1/2 NW1/4 NW1/4 GOVT LOT 2 LESS RIDS L WORK SUBJECT TO FIELD B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASH S INSPECTION FOR UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WO D. CODE COMPLIANCE INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DES N SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 T 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" SMALLER LAG SCREWS. 18. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTE THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE "TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DE SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, UNLESS OTHER' NOTED, SHALL CONFORM TO IBC TABLE 2304.9.1. COORDINATE THE SIZE LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWING; B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WE ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHAL PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AN BEAM OR HEADER BEARING LOCATIONS. ALL NEW WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP P END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP P WITH 16d @ 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d N APPROVED PLANS MUST BE ON JOB SITE ASCE® AMERI CAN SOCIETY OF CIVIL ENGINEERS Address: 21611 92nd Ave W Cit Of Edmon y w uE Building Department T�llork T SEISMIC RETROFIT IaN sAddress 21611 92ND AVE W VD Owner OONG AApproved Date 02/11 /2025 Building Official E1rl.C/ -T�ermit Number BLD2025-013 @ 4" O.C. EACH SIDE JOINT. ALL NEW STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO ROWS OF 16d NAILS @ 12" ON -CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON -CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16d @12" ON -CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON -CENTER. end Retrofit Plan Scale: 3/16" = 1'-0" INDICATES AREA OF SEISMIC RETROFIT UPGRADE Seismic ASCE Hazards Report Standard: ASCE/SEl7-16 Latitude: 47.802659 Risk Category: II Longitude:-122.355877 Soil Class: D - Default (see Elevation: 412.6774176544958 ft Section 11.4.3) (NAVD 88) -av gar»r h� r Site Soil Class: D - Default (see Section 11.4.3) Results: Ss : 1.281 SDI : N/A S, 0.451 TI 6 Fa 1.2 PGA: 0.545 F N/A PGA M : 0.654 SMs : 1.538 FIDGA 1.2 SM1 N/A le 1 SIDS : 1.025 C 1.356 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Fri Jan 24 2025 Date Source: USGS Seismic Design Maps Seismic Retrofit (IBC 2021 /ASCE 7-16 Seismic Criteria: OCCUPANCY CATEGORY: II NO. STORIES ABV. GR. 1.5 IMPORTANCE FACTOR: 1.0 SITE CLASS D (Default) SDS= 1.000 R = 6.5 SDI= 0.556 h = 20 ft Period, T= 0.189 Ss = 1.281 Cs= 0.154 51 = U.45 I Lsmax= U.452 Fa = 1.2 Csmin= 0.010 F = 1.849 Controlling Cs= 0.154 Buildina Weiaht Floor DL (psf) A (sq.ft.) W (Ibs) Roof 20 2050 41000 1.5 22 104 2288 1st 17 1764 29988 0 Surn=1 73276 Wall Seismic Loadin Section 12.8.1.3 Exceptions Regular Structure** <_ 5 Stories above grade Yes Yes T <_ 0.5s P = 1.0 Yes Yes Not Site Class E or F Yes Risk Category I or II Yes If all exceptions are met, SDS may be taken as 1, but not less than 0.7*(Calculated SDs) **Regular Structure per Section 12.3.2 Redundancy Factor, p = 1.0 Base Shear, VBASE = 11273 Ibs VASD = •7VBase = 7891 Ibs Wall V (Ibs) Wall (ft) v (Ibs/ft) North Exterior 3946 16.0 247 South Exterior 3946 16.0 247 West Exterior 3946 16.0 247 East Exterior 3946 16.0 247 Sill Plate Bolting: Maximum Anchor Spacing For Various Retrofit Anchor Options Wall 1/2" Dia Titen HD URFP FRFP SDWS Option @ Rim North Exterior 32 in oc 48 in oc 72 in oc 8 in oc South Exterior 32 in oc 48 in oc 72 in oc 8 in oc West Exterior 32 in oc 48 in oc 72 in oc 8 in oc East Exterior 32 in oc 48 in oc 72 in oc 8 in oc Pony Wall Retrofit: Wall North Exterior South Exterior West Exterior East Exterior Hw (ft) Edge Nailing A35 Uplift (Ibs) Trib Di. (Ibs) Net Uplift (Ibs) Holdown Min. Lw w/ no HD 4.7 8d@4 16 in oc 1 151 600 791 HDU2 N/A 0.0 8d@4 16 in oc 0 0 0 None N/A 0.0 8d@4 16 in oc 0 0 0 None N/A 0.0 8d@4 16 in oc 0 0 0 None N/A CLIENT: Sound Seismic 7543 15th Ave NW Seattle, WA 98117 PH 2O6.352.5644 A 11515th Ave E, Ste B 206-734-3946 Seattle, WA 98112 radial-engineering.com Copyright 2025 Radial Engineering - All Rights Reserved REVISIONS: DESIGNED BY: GJS APPROVED BY: RJA PROJECT: Oong Residence 21611 92nd Ave W Edmonds, WA 98020 JURISDICTION STAMP: ISSUE: 01-27-24 RECEIVED Jan 29 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Permit SHEET TITLE: Structural Notes Plan & Calculations SCALE: 1 /4'' = 1'-0" U. N. O DATE: 01 /27/2025 PROJECT No: 1013-0003-25 SHEET NO: Sill HDUx HOLDOWN TO DBL. END STUD, REF. DETAIL SHEET S2.1 PROVIDE 12" WIDE/2" CDX (E) WALL ABOVE PLYWOOD PRENAILED TO LEDGER W/ 8d @ 4"oc ASSUMED (E) NAILING (E) 2x CAR DECKING, FIELD VERIFY a (E) PARTIALLY EMBEDDED ° 2x SILL PLATE CV a NAIL PLYWOOD TO (E) CAR 41 DECKING W/ (3) ROWS 6d x 2" COMMON NAILS @ 31oc (E) FOUNDATION WALL PROVIDE P.T. 2x12 LEDGER W/2"O TITEN HD CONC. SCREWS @ 32"oc (312" conc. embed) ALL FASTENERS INTO PRESSURE TREATED WOOD SHALL BE GALV. OR STAINLESS STEEL PER GENERAL STRUCTURAL NOTES Retrofit Detail PROVIDE A35 CLIPS @ 16"oc, INSTALL W/ PALM NAILER PROVIDE 2x SHIM PLATE x 2'-8" W/(6)SDWS SCREWS, EMBED (E) WALL ABOVE — 22" INTO (E) SILL PLATE @ NEW FRFP LOCATIONS ASSUMED (E) NAILING 1311 1311 3 " 3 " 3 " 11311 11311 3 " VERIFY (E) 2x RIM OR FULL -DEPTH BLKG, I I (E) 2x SILL PLATE Lf— —0J (E) FOUNDATION WALL (E) JOISTS & SHEATHING 4 ° PROVIDE FRFP @ 72"oc W/ (5)SDS25212 SCREWS & (2) 2"!l0 TITEN HD CONC SCREWS (3)/2" CONC. EMBED) Retrofit Detail 2 (E)WALL ABOVE ASSUMED (E)NAILING AT (E)RIM (E)JOISTS & SHEATHING VERIFY (E)2x RIM OR FULL -DEPTH BLKG, PROVIDE2" CDX PLYWOOD, SDWS22600 SCREWS @ BLOCK EDGES & NAIL W/ 8d @ 8"oc THRU T.P. INTO RIM 4"oc EDGES, 12"oc FIELD (E) SILL PLATE W/ NEW 12`0 HDU2-SDS2.5 W/ (6)SDS25212 TITEN HD CONC. SCREWS @ SCREWS TO DOUBLE STUDS 32"oc (3%" conc. embed) (where occurs) PROVIDE%"x3"x3" STEEL PLATE WASHER @ NEW SILL PLATE EPDXY GROUT %">D THREADED ROD I I. ANCHORAGE �I I 8"(min.) INTO (E) CONCRETE @ NEW HD LOCATIONS, INSTALL @ SLIGHT ANGLE 23/4" LJ TO ACHIEVE EDGE DISTANCE min. ° a (E) FOUNDATION WALL Retrofit Detail 3 CLIENT: Sound Seismic 7543 15th Ave NW Seattle, WA 98117 PH 2O6.352.5644 11515th Ave E, Ste B 206-734-3946 Seattle, WA 98112 radial-engineering.com Copyright 2025 Radial Engineering - All Rights Reserved REVISIONS: 01-27-24 DESIGNED BY: GJS APPROVED BY: RJA PROJECT: oong Residence 21611 92nd Ave W Edmonds, WA 98020 JURISDICTION STAMP: RECEIVED Jan 29 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ISSUE: Permit SHEET TITLE: Retrofit Details SCALE: 3/4'' = 1 '-0" U . N . O DATE: 01 /27/2025 PROJECT NO: 1013-0003-25 SHEET NO: S2,1