REVIEWED BLD BLD2024-1042+Energy_Calculations+8.9.2024_11.31.09_AM+4431930RECEIVED Aug 16 2024 WSU Code Compliance Calculator, WSEC 2021 CITY OFEDMONDS BLD2024-1042 Project Information DEPARTMENT Select Homes Plan 3167 Contact Information Nash Architects 8003 118th Ave NE Kirkland, WA 98033 (425)828-4117 Messages I Results * ••ti REVIEWED UA Reduction = 33.81, Proposed UA is better than baseline by 8 % BY CITY OF EDMONDS Vertical glazing area exceeds 15% of floor area. BUILDING DEPARTMENT: Whole House Mechanical Ventilation Airflow Rate: 80 CFM with Run Time Percent of 100%, Balanced, Distributed Maximum allowable total measured duct leakage: 253 CFM25 ' Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. PHIAL r 010 JCI Ur What code compliance pathway are you using? Total UA Alternative, Whole Building Trade Off Analysis Project Building Type? New Construction Occupancy Type? R3 Single family homes and duplexes Code Version? WSEC 2021 WSEC-R Rev: Oct. 2023, https://www.sbcc.wa.gov/sites/default/files/2023-12/C Classification: Medium Dwelling Unit -- 3167 sq. ft. Baseline Description: Code Baseline - Maximum baseline window area is 15 % of floor area. About Your Selection: No exempt window or door areas RESULTS - Comparison of Baseline and Pro Component Performance. R occupancies Doors U Overhead Glazing U Vertical Glazing U Flat/Vaulted Ceilings U Wall (above grade) U Floors over Crawlspace U = Slab on Grade F Below Grade Wall U = Below Grade Slab F = Baseline U ' Area UA 0.300 37 11.2 0.500 0 0.0 0.300 475 142.5 0.024 1,950 46.8 0.056 3,250 182.0 0.029 1,950 56.6 0.540 0 0.0 N/A 0 N/A 1 0 " Values trom I able K4Uz.l .Z (Uct ZUZ J) Baseline UA Total 439.1 Required Credits 8.0 Proposed Design U Area UA 0.280 37 10.5 0 0.0 0.250 495 123.8 0.024 1,950 46.8 0.054 3,250 175.5 0.025 1,950 48.8 0 0.0 0 0.0 0 0.0 Proposed UATotal 405.3 Proposed Credits 8.0 from Tables 406.2 and 406 UA Percent Reduction 7.7% UA Reduction 33.8 Table R406.2 Energy Equalization Credits IL -1L Fuel Normalization Energy Credits Total Credits System No. Full Description Select System T e Credits 406.2 (406.3) 406.2 & 406.3 For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat Variable Refrigerant Heat Pump or Air-to- 4 pump units that are configured to provide both heating and cooling and are rated in Water Heat Pump 3.0 5.0 8.0 accordance with AHRI 550/590 Table R406.3 Energy Credits Option No. Category Select Options Energy Credits Brief Description of Selected Options* 1 Efficient Building Envelope Not Selected 0.0 - Per Section R402.4.1.2 / 2.0 ACH50 / For R-2, 0.25 cfm per ft2 2 Air Leakage Control and Efficient Ventilation Option 2.1 1.0 at 50 Pa. / HRV with min SHR eff of 0.65 per IRC Section M1505.3 or IMC Section 403.8 Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 3.1 -3.10 High Efficiency HVAC Option 3.6 1.0 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. 3.11 High Efficiency HVAC: Smart Thermostat Not Selected 0.0 X:\Shared\Current\2024 File by Client\Select Homes 2024\98th SP-Edmonds\Lot 1- 3267-GRXWSEC WC72BM21 - Plan 3267.xism 7/10/2024 WSU Code Compliance Calculator, WSEC 2021 4 High Efficiency HVAC Distribution System Option 4.1 0.5 Ducts/distribution system in conditioned space per R403.3.2 Electric resistance, hydronic, ductless and gas fired systems < 80 % AFUE systems not permitted 5.1 Efficient Water Heating: Drain Heat Recovery 0.0 5.2 Efficient Water Heating: Compact Hot Water Distribution Option 5.2 0.5 Compact Hot Water Distribution System Max volume between heat source and fixture is 16 Oz per section R403.5.2, on demand circ. Pump may be required. 5.3-5.8 Efficient Water Heating Option 5.6 2.0 Electric heat pump water heater meeting NEEA Tier 3. 6 Renewable Electric Energy kWh 0.0 7 Appliance Package Not Selected 0.0 - Energy Credits 5.0 *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements THERMAL ENVELOPE DETAILS - Conditioned Floor Area. Pr000sed Desianl 3,167 ISO. ft Classification Medium Dwelling Unit Notes Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet I"`n Feet I"`n Area UA U=0.28 0.28 1 3 ° 8 ° 24 6.7 U=0.28 0.28 1 2 0 6 8 13 3.7 0 0.0 0 0.0 01 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Sum of Area and UA 37 10.5 Exterior Doors Area Weighted U 0.280 Overhead Glazing Plan ID Component Description Ref. Glazing U Qt. Width Height Area UA Feet I coon Feet""n Sum of Area and UAI 0.01 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 14 Plan Component Glazing Width Height Feet I"On Feet io"n ID Description Ref. U Qt. Area UA 1 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 3 3 ° 6 ° 54.0 13.50 2 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 5.00 ° 5 ° 25.0 6.25 3 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 8 ° 2 ° 16.0 4.00 4 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 3 6 0 6 0 108.0 27.00 5 U=0.25 (2021 1.2; 2018 1.4) Table 406.21 0.25 1 8 ° 8 ° 64.0 16.00 6 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 1 8 01 4 ° 32.0 8.00 7 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 8 ° 2 ° 16.0 4.00 8 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 4 2 ° 2 ° 16.0 4.00 9 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 8 ° 4 ° 32.0 8.00 10 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 1 5 ° 2 01 10.0 2.50 111 1 U=0.25 (2021 1.2; 2018 1.4) Table 406.2 0.25 2 5 0 4 0 40.0 1 10.00 1 21 1 U=0.25 (2021 1.2; 2018 1.4) 1 Table 406.21 0.25 1 1 61 ° 4 s 27.0 6.75 X:\Shared\Current\2024 File by Client\Select Homes 2024\98th SP-Edmonds\Lot 1- 3267-GRXWSEC WC72BM21 - Plan 3267.xism 7/10/2024 WSU Code Compliance Calculator, WSEC 2021 13 U=0.25 2021 1.2; 2018 1.4 Table 406.2 0.25 2 3 5 30.0 7.50 14 U=0.25 2021 1.2; 2018 1.4 Table 406.2 0.25 1 5 ° 5 ° 25.0 Sum of Area and UA 495.0Ej Vertical Glazing Area Weighted U Vertical Glazing and Doors Area Weighted U FlatlVaulted Ceilings Plan ID Component Descri lion Ref. Attic U Area UA R60 blown Attic STD baffled 2021 Code Baseline 10-7 0.024 1,950 46.8 Sum of Area and UAI 1,9501 46.8 Walls (Above Grade Plan ID Component Description Ref. Wall U Net Area UA R21 cavity+RO foam INT 2X6W Lap (2018 Code Baselin 10-5 0.054 3,250 176 Sum of Area and UAI 3,2501 176 Floor over crawl or exterior Plan ID Component Description Ref. Floor U Area UA main R38 vented Joist 16oc 2021 1.2, 1,3; 2018 1.3-1.5 10-3 0.025 1,950 49 Sum of Area and UAI 1,9501 49 Slab on Grade less than 2 feet belowgrade) Plan ID Component Description Ref. Slab F Slab Perim FP No slab on grade NA 0 Sum of Perimeter and FP1 01 0 Below Grade Walls and Slabs Plan ID Component Description Slab Depth Ref. Wall U Wall Area Wall UA Slab F Slab Perim Slab UA Sum of Area, Length and UAI 01 0.01 01 0 Links to Download Forms, Checklists and Other Resources • Link Compliance Certificate Compliance Certificate Instructions Insulation Certificate for Residential New Construction Insulation Certificate Duct Testing Affadavits Existing Construction Affidavit, Existing New Construction Affidavit, New Prescriptive Checklist for 2018 WSEC Prescriptive Checklist Alterations (Remodel) Worksheet Worksheet Show Ventilation Calculator? I Show Ventilation Requirements X:\Shared\Current\2024 File by Client\Select Homes 2024\98th SP-Edmonds\Lot 1- 3267-GRXWSEC O C720M21 - Plan 3267.xism 7/10/2024 WSU Code Compliance Calculator, WSEC 2021 Conditioned Floor Area 3,167 sq. ft. Number of Bedrooms 5 Run -Time Percent in Each 4-Hour Segment 100 Is the system Balanced? Balanced Verify system meets definition of'Balanced Whole -House Ventilation' Is the system Distributed? Distributed Verify system meets definition of'Distributed Whole -House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 80 CFM Show Distribution System Calculator? I Show HVAC Thermal Distribution System Download RS-33 (2018) htt ://www.ener .wsu.edu/Documents/Duct % 2OTestin % 20Standards Is this a hydronic heating system? lNo Location of Ducts lConditioned Space Location of Air Handler lConditioned Space Is Duct Testing Required? Yes Maximum Duct Leakage: Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft. Maximum allowable total measured duct leakage 253 CFM25 A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. Show Heating System Sizing? Show Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: httos://befterbuiltnw.com/resources/hvac-sizing-tool Nearest Weather Station lEdmonds Indoor Design Temperature 70 F Outdoor Design Temperature 24 F Design Temperature Difference (AT) 46 F Conditioned Floor Area, Proposed Design Conditioned Volume Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Sum of UA Envelope Heat Load Sum of UA X AT Air Leakage Heat Load ((VolumeX 0.6)XAT)X.018)) Building Design Heat Load Air Leakage + Envelope Heat Loss 3,167 ft2 25,336 ft3 Heat Pump Conditioned Space 405 18,642 Btu / Hour 12,587 Btu / Hour 31,229 Btu / Hour Building and Duct Heat Load 31,229 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 39,036 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 11.4 kW Building and Duct Heat Loss X 1.40 for all other systems X:\Shared\Current\2024 File by Client\Select Homes 2024\98th SP-Edmonds\Lot 1- 3267-GRXWSEC 0 C720M21 - Plan 3267.xism 7/10/2024