Loading...
APPROVED BLD ENG BLD2025-0013+Civil_Plan+1.6.2025_10.56.43_AM+4697410The following documentation shall be available on site for the building inspector APPROVED BY PLANNING ■ = ❑ COE APPROVED ARCHITECTURAL PLAN SET ' F] COE APPROVED STRUCTURAL PLAN SET � Feb 07 2025 F-1 COE REVIEWED CALCULATION PACKET - ❑ ENERGY CREDIT WORKSHE T Nothing in the permit approval process shall be SITE PLAN • interpreted as allowing or permitting the maintenance � of any currently existing illegal, nonconforming or ■ ❑ CIVIL PLAN unpermitted building, structure or site condition which � is outside the scope of the permit application, regardless Geo report and structural design Fx I of whether such building, structure or condition is . shown on the site plan or drawing. Such building, ❑ structure or condition may be the subject of a separate / enf rcement action. ■ CJTY OF EDM7DS BUILDING DE j RTMENT 2021 \ I ALL WTO RK�UBJ/ECT FI LD / INS ECT�ON OR I COD COPLINC� i I PL I I SCHEDULE INSPECTION FOR NFILTRATION YSTEM. ITIE BA PIPI T I PROPOSE ON' REMOVE WALL AND RESTORE TO EXIST. GRADE I 00 0 231.: N N N I I I ALL POSED URFACES TO BE C VERED W THIN 2 DAYS I I I 1 I INO WORK I PERMITTED IN THE CITY RIGHT-OF-WAY. ALL STAGI G, EQUIPMENT, MATERIALS, C. SHALL BE LOCATED N PRIVATE PROPERTY. 1 1 I I I I 1 I I GRADING NOTES 1. NO TREES TO BE REMOVED WITHIN PROJECT ARItA. 2. STOCKPILES EXPOSED MORE THAN 24 HOURS SHALL I BE COVERED WITH PLASTIC SHEETING. I 3. SOILS EXPOSED FORE MORE THAN 24 HOURS SHALL BE COVERED WITH STRAW OR HOG FUEL. 4. FILTER FABRIC FENCE SHALL BE INSTALLED AS SHOWN ON THE PLANS. 5. NO ADDITIONAL SETBACKS FROM TOE AND TOP OF WALL ARE REQUIRED BY THE GEOTECHNICAL ENGINEER I I OF RECORD. 6. GRADING QUANTITIES: ± 72 CUBIC YARDS TO BE GRADED ON —SITE. 0 I 6 INO CH NGE TO THIS I WALL UNDER XIN H IGHT / 249.85 I GRASS N + +` AREA I / _ 248. — 48. 3 248.62 5y X245.07 — / � 1 REMOVE END °� �2.47 / OF WALL IN 2. 1 =DAI+I c2 1��24 . . _ I N N I ALL DISTURBED SOILS SHALL BE COMPOST AMENDED P R CITY OF E MONDS STANDARD DET IL SD-642 OR APPROVED EQUAL. I \ "WO CHANGE THIS WALL Ut ' IN HEIGHT I 1 Applicant shall repa r/replace all I damage to utilities r fronta e improvements in City right-of-way OWNE /CONl RACTOR I RESPONSIB I E FOR per city standards that is caused or EROSION CONTROL DRAINA�E occurs during the permuted project. ND 1 \ I I ' 1 � 1 DR 1 I 1 I 1 O NER/CONTRACTOR RESPONSIB E FOR LOCA NG ALL N SITE UTILITIES. TION REVISION TO ANY LITIES MAY REQ�ELOCA IRE A SEPE TE PERMIT. I I i 0• �' EMENT DTI LI EA �T PER P AFW 1146873 a 260.25 �1 N A N II I I I I I I ENGINEERING DI IS ON APPROVED S NOT D 1 /2�/202E ConstrucWon or Rec6nstru¢tion of ring walls s/PAII be under supervision of the Geo-Technical E gineer. All observatignireports in ccordance with ptese-p-lans and su orting documentation �"11 be submitted to the city inspector.. City Of Edmonds Building Department Work RETAINING WALLS Address 620 VIEW PL Owner HAILE Approved Date 01 /28/2025 Building Official Erl.(i Permit Number BLD2025-0013 Playfield EDMONDS Main St Dayton St U) Maple St L_ Yost Pa) (° Alder St Alder St a Walnut St Walnut St Q L Cedar St U) > St ro > Q U)Spruce Q a) > L (O Q L it 215�h Pine St Q (n a) L (o > Q 217th St U) co > Cf) > Fir St Q Q Q L > Q Q L_ U 00 rn \ co Elm St �04 VICINITY MAP 1 " = 2, 000' PROJECT DATA PROPERTY OWNER/APPLICANT: TESHOME A. HAILE & MENADIT A. MENGISTU 620 VIEW PL EDMONDS, WA 98020 (206) 859-8053 TESHABATE@YAH00.COM PROJECT CONTACT/PLAN PREPARER: PUGET SOUND PLANNING, LLC ATTN: LEE A. MICHAELIS 6100 219TH ST SW, SUITE 480 MOUNTLAKE TERRACE, WA 98043 (425) 830-1046 LEE.MICHAELIS@PUGETSOUNDPLANNING.COM GEOTECHNICAL ENGINEER: COBALT GEOSCIENCES, LLC ATTN: PHIL HABERMAN, PE P.O. BOX 1792 NORTH BEND, WA 98045 (206) 331-1097 PHILOCOBALTGEO.COM SITE/ZONING DATA SITE ADDRESS: PARCEL NUMBER: TOTAL LOT AREA: EXISTING ZONE: BUILDING SETBACK LINES MAXIMUM BUILDING HEIGHT: SCOPE OF WORK THIS PERMIT 620 VIEW PL 00606000000800 7,015 SF RS-6 FRONT: 20 FEET REAR: 15 FEET SIDE: 5 FEET 25 FEET REMOVE RETAINING WALLS THAT EXCEED 3 FEET WITHIN ZONING SETBACKS. RECONSTRUCT PORTIONS OF RETAINING WALLS PER GEOTECHNICAL ENGINEER RECOMMENDATIONS. REGRADE AREAS WITHIN SETBACKS SO THAT THE SLOPE DOES NOT EXCEED A 3:1 SLOPE. LEGAL DESCRIPTION LOT 8, VIEW MANOR, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 15 OF PLATS, PAGE 74, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. RETAINING WALL LEGEND C - - - - ::1 EXISTING WALL TO BE REMOVED EXISTING RETAINING WALL TO REMAIN EXISTING RETAINING WALL TO BE RE —CONSTRUCTED PER C-----� GEOTECHNICAL ENGINEER RECOMMENDATIONS x 244.18 SURVEY SPOT ELEVATIONS PRIOR TO RECONFIGURATION/REMOVAL OF WALLS. NEW TOW NEW WALL ELEVATIONS AFTER RECONSTRUCTION TO NEW BOW COMPLY WITH CITY REGULATIONS X SILT FENCE SCALE 1" = 10' 0' 5' 10' 20 30' W z O C/)w O � M 0 0 03 '4 rn v w¢� Iwo 7 0 2 w w v N � � � o�a� oz o 0 A. W N N C=2 _ C/, `o RECEIVED Jan 07 2025 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT cc Z w Q Z w U Q Z W C, O Z w .J m Q LLJ DRAWN DATE: 1213012024 DRAWN BY: LAM CHECKED BY: TL PSP PROJECT NO. 2024-29 SHEET NAME CIVIL PLAN SHEET NUMBER C-1 PRINT DATE: 12/30/2024