APPROVED BLD ENG BLD2025-0013+Civil_Plan+1.6.2025_10.56.43_AM+4697410The following documentation shall be available on
site for the building inspector
APPROVED BY PLANNING
■
= ❑ COE APPROVED ARCHITECTURAL PLAN SET '
F] COE APPROVED STRUCTURAL PLAN SET
� Feb 07 2025
F-1 COE REVIEWED CALCULATION PACKET
-
❑
ENERGY CREDIT WORKSHE T
Nothing in the permit approval process shall be
SITE PLAN
•
interpreted as allowing or permitting the maintenance
�
of any currently existing illegal, nonconforming or
■
❑
CIVIL PLAN
unpermitted building, structure or site condition which
�
is outside the scope of the permit application, regardless
Geo report and structural design
Fx I
of whether such building, structure or condition is
.
shown on the site plan or drawing. Such building,
❑
structure or condition may be the subject of a separate
/
enf rcement action.
■ CJTY OF EDM7DS BUILDING DE
j RTMENT 2021 \
I
ALL WTO
RK�UBJ/ECT
FI LD /
INS ECT�ON OR I
COD COPLINC�
i I
PL
I
I
SCHEDULE
INSPECTION FOR
NFILTRATION
YSTEM.
ITIE BA
PIPI T
I
PROPOSE ON'
REMOVE WALL
AND RESTORE
TO EXIST. GRADE
I
00 0 231.:
N N N
I
I
I
ALL POSED URFACES TO
BE C VERED W THIN 2 DAYS
I
I
I
1
I
INO WORK I PERMITTED IN THE CITY RIGHT-OF-WAY.
ALL STAGI G, EQUIPMENT, MATERIALS, C. SHALL BE
LOCATED N PRIVATE PROPERTY.
1 1
I I I
I 1
I
I
GRADING NOTES
1. NO TREES TO BE REMOVED WITHIN PROJECT ARItA.
2. STOCKPILES EXPOSED MORE THAN 24 HOURS SHALL I
BE COVERED WITH PLASTIC SHEETING. I
3. SOILS EXPOSED FORE MORE THAN 24 HOURS SHALL
BE COVERED WITH STRAW OR HOG FUEL.
4. FILTER FABRIC FENCE SHALL BE INSTALLED AS SHOWN
ON THE PLANS.
5. NO ADDITIONAL SETBACKS FROM TOE AND TOP OF
WALL ARE REQUIRED BY THE GEOTECHNICAL ENGINEER I I
OF RECORD.
6. GRADING QUANTITIES: ± 72 CUBIC YARDS TO BE
GRADED ON —SITE. 0
I 6
INO CH NGE
TO THIS I WALL
UNDER XIN H IGHT
/ 249.85
I
GRASS
N + +` AREA
I / _
248. —
48. 3
248.62
5y X245.07
— / �
1 REMOVE END °� �2.47 /
OF WALL IN 2.
1 =DAI+I c2 1��24 . . _ I
N N
I
ALL DISTURBED SOILS SHALL BE
COMPOST AMENDED P R CITY OF
E MONDS STANDARD DET IL SD-642 OR
APPROVED EQUAL.
I \ "WO CHANGE
THIS WALL Ut
' IN HEIGHT
I
1
Applicant shall repa r/replace all I
damage to utilities r fronta e
improvements in City right-of-way OWNE /CONl RACTOR I RESPONSIB I E FOR
per city standards that is caused or EROSION CONTROL DRAINA�E occurs during the permuted project. ND
1 \ I
I '
1
� 1
DR 1
I
1
I
1
O NER/CONTRACTOR RESPONSIB E FOR LOCA NG
ALL N SITE UTILITIES. TION REVISION TO ANY
LITIES MAY REQ�ELOCA
IRE A SEPE TE PERMIT. I
I i 0• �' EMENT
DTI LI EA �T
PER P
AFW 1146873
a 260.25
�1 N A N
II
I
I
I
I
I
I
ENGINEERING DI IS ON
APPROVED S NOT D
1 /2�/202E
ConstrucWon or Rec6nstru¢tion of
ring walls s/PAII be under supervision
of the Geo-Technical E gineer. All
observatignireports in ccordance with
ptese-p-lans and su orting
documentation �"11 be submitted to the
city inspector..
City Of Edmonds
Building Department
Work RETAINING WALLS
Address 620 VIEW PL
Owner HAILE
Approved Date 01 /28/2025
Building Official Erl.(i
Permit Number BLD2025-0013
Playfield
EDMONDS
Main St
Dayton St
U)
Maple St
L_
Yost Pa)
(° Alder St
Alder St
a Walnut St
Walnut St
Q
L
Cedar St
U)
>
St
ro
> Q
U)Spruce
Q
a)
>
L
(O
Q
L
it
215�h
Pine St
Q
(n
a)
L
(o
>
Q
217th St
U)
co
>
Cf) > Fir St
Q
Q
Q
L
> Q
Q
L_
U
00
rn
\ co Elm St
�04
VICINITY MAP
1 " = 2, 000'
PROJECT DATA
PROPERTY OWNER/APPLICANT:
TESHOME A. HAILE & MENADIT A. MENGISTU
620 VIEW PL
EDMONDS, WA 98020
(206) 859-8053
TESHABATE@YAH00.COM
PROJECT CONTACT/PLAN PREPARER:
PUGET SOUND PLANNING, LLC
ATTN: LEE A. MICHAELIS
6100 219TH ST SW, SUITE 480
MOUNTLAKE TERRACE, WA 98043
(425) 830-1046
LEE.MICHAELIS@PUGETSOUNDPLANNING.COM
GEOTECHNICAL ENGINEER:
COBALT GEOSCIENCES, LLC
ATTN: PHIL HABERMAN, PE
P.O. BOX 1792
NORTH BEND, WA 98045
(206) 331-1097
PHILOCOBALTGEO.COM
SITE/ZONING DATA
SITE ADDRESS:
PARCEL NUMBER:
TOTAL LOT AREA:
EXISTING ZONE:
BUILDING SETBACK LINES
MAXIMUM BUILDING HEIGHT:
SCOPE OF WORK THIS PERMIT
620 VIEW PL
00606000000800
7,015 SF
RS-6
FRONT: 20 FEET
REAR: 15 FEET
SIDE: 5 FEET
25 FEET
REMOVE RETAINING WALLS THAT EXCEED 3 FEET WITHIN ZONING
SETBACKS. RECONSTRUCT PORTIONS OF RETAINING WALLS PER
GEOTECHNICAL ENGINEER RECOMMENDATIONS. REGRADE AREAS WITHIN
SETBACKS SO THAT THE SLOPE DOES NOT EXCEED A 3:1 SLOPE.
LEGAL DESCRIPTION
LOT 8, VIEW MANOR, ACCORDING TO THE PLAT THEREOF RECORDED IN
VOLUME 15 OF PLATS, PAGE 74, RECORDS OF SNOHOMISH COUNTY,
WASHINGTON.
SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON.
RETAINING WALL LEGEND
C - - - - ::1 EXISTING WALL TO BE REMOVED
EXISTING RETAINING WALL TO REMAIN
EXISTING RETAINING WALL TO BE RE —CONSTRUCTED PER
C-----� GEOTECHNICAL ENGINEER RECOMMENDATIONS
x 244.18 SURVEY SPOT ELEVATIONS PRIOR TO
RECONFIGURATION/REMOVAL OF WALLS.
NEW TOW NEW WALL ELEVATIONS AFTER RECONSTRUCTION TO
NEW BOW COMPLY WITH CITY REGULATIONS
X SILT FENCE
SCALE 1" = 10'
0' 5' 10' 20 30'
W
z
O
C/)w
O
�
M
0 0
03
'4 rn v
w¢�
Iwo
7
0
2 w w v
N � � �
o�a�
oz o
0
A.
W N N
C=2 _
C/, `o
RECEIVED
Jan
07 2025
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
cc
Z
w Q
Z
w
U
Q
Z
W
C, O Z
w
.J
m
Q
LLJ
DRAWN DATE:
1213012024
DRAWN BY:
LAM
CHECKED BY:
TL
PSP PROJECT NO.
2024-29
SHEET NAME
CIVIL
PLAN
SHEET NUMBER
C-1
PRINT DATE: 12/30/2024