Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1143_Manufacturer_Specifications_and_Installation_Instructions_9.11.2023_1.33.21_PM_3775723
wu..... ...t�, • New composite base pan — dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed • Improved tubing design — reduces vibration and stress, making unit quieter and reducing opportunity for leaks • Optimized defrost characteristics - decrease defrosting and provide better home comfort • Powder coat paint system — for a long lasting professional finish • Optimized reversing valve sizing — improves shifting perfor- mance for quieter unit operation and increased life of the system • Enhanced mufflers — help to dissipate vibration energy for quieter unit operation • Scroll compressor — a sound abating feature added to the com- pressor significantly reduces noise when system transitions in and out of defrost mode • Modern cabinet aesthetics — increased curb appeal with visu- ally appealing design • Curved louver panels — provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity • Optimized fan orifice — optimizes airflow and reduces unit sound • Rust resistant screws — confirmed through 1500-hour salt spray testing • PlusOneTm Expanded Valve Space — 3"-4"-5" service valve space — provides a minimum working area of 27-square inches for easier access RP15 Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] vy?_e/ a s `11 e&s LISTED "Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov." • Integrated heat pump lift receptacle — allows standard CPVC stands to be inserted into the base • PlusOneTm Triple Service Access — 15" wide, industry leading corner service access — makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly • Diagnostic service window with two -fastener opening — provides access to the TXV valves and the heat pump reversing valve before opening the unit. • External gauge port access — allows easy connection of "low -loss" gauge ports • Single -row condenser coil — makes unit lighter and allows thor- ough coil cleaning to maintain "out of the box" performance • 35% fewer cabinet fasteners and fastener -free base — allow for faster access to internal components and hassle -free panel removal • Service trays — hold fasteners or caps during service calls • QR code — provides technical information on demand for faster service calls • Fan motor harness with extra -long wires — allows unit top to be removed without disconnecting fan wire FORM NO. P22-807 REV. 11 Table of Contents RP15 Series Standard Feature Table............................................................................................3 AvailableSKUs........................................................................................................3 Features& Benefits..............................................................................................4-5 Model Number Identification................................................................................6-7 PhysicalData............................................................................................................8 ElectricalData..........................................................................................................8 Accessories..............................................................................................................9 WeightedSound Power............................................................................................9 UnitDimensions......................................................................................................10 Clearances..............................................................................................................11 WiringDiagrams....................................................................................................12 ApplicationGuidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-16 PerformanceData..................................................................................................17 GuideSpecifications..............................................................................................18 LimitedWarranty....................................................................................................19 Standard Feature Table/Available SKUs RP15 Series Standard Feature Table Feature 18 24 30 36 42 48 60 R-410a Refrigerant V J J J J J J Maximum SEER 15.0 15.0 15.0 15.0 15.0 15.0 15.0 Maximum EER 12.5 12.5 12.5 12.5 12.5 12.5 12.5 Maximum HSPF 9 9 9 9 9 9 9 Scroll Compressor J J J J ✓ J J Field Installed Filter Drier J J J J J J J Front Seating Service Valves J J J J J J J High Pressure Switch J J J J J ✓ J Low Pressure Switch J J J J ✓ J ✓ Internal Pressure Relief Valve J J ✓ J J J J Internal Thermal Overload J J J J J J J Long Line capability J J J J J J J Low Ambient capability with Kit J J J J J J J 3-4-5 Service Valve Access J J J J J J J Composite Basepan J J J J J J J 2 Screw Control Box Access J J J J J J J 15" Access to Internal Components J J J J J J J Quick release louver panel design J J J J J J J No fasteners to remove along bottom J J J J J J J Optimized Venturi Airflow J J J J J J J Single row condenser coil J J J J J J J Powder coated paint J J J J J J J Rust resistant screws J J J J J J J OR code J J J J J J J External gauge ports J J J J J J J Service trays J J J J J J J ✓ = Standard Available SKUs Available Models Description RP1518BJ1 NA Achiever®1 1/2 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1518CJ1 NA Achiever®1 1/2 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1524BJ1 NA Achiever® 2 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1530BJ1 NA Achiever® 2 1/2 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1536AC1 NA Achiever® 3 ton 15 SEER Single -Stage Heat Pump-208/230/3/60 RP1536AJ1 NA Achiever® 3 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1542BC1 NA Achiever® 3 1/2 ton 15 SEER Single -Stage Heat Pump-208/230/3/60 RP1542BJ1 NA Achiever® 3 1/2 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1548AC1 NA Achiever® 4 ton 15 SEER Single -Stage Heat Pump-208/230/3/60 RP1548AJ1 NA Achiever® 4 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 RP1560AC1 NA Achiever® 5 ton 15 SEER Single -Stage Heat Pump-208/230/3/60 RP1560AJ1 NA Achiever® 5 ton 15 SEER Single -Stage Heat Pump-208/230/1/60 Features & Benefits RP15 Series Introduction to RP15 Heat Pump The RP15 is our 15 SEER heat pump and is part of the Ruud heat pump product line that extends from 14 to 20 SEER. This highly featured and reliable heat pump is designed for years of reliable, efficient operation when matched with Ruud indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base ( 1❑) reduces sound emission, elimi- nates rattles, significantly reduces fasteners, eliminates corrosion and has integrated brass compressor attachment inserts (❑2 ). Furthermore it has incorporated into the design, water manage- ment features, means for hand placement (❑s) for unit maneu- vering, screw trays (74) and inserts for lifting unit off pad. (0) 1❑ ❑ 2 a Is. 4 © ❑3 0 Service valves (©) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading installation ease. The minimum 27-square inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clear- ance for easy brazing of the suction and discharge lines to ser- vice valve outlets, easy access and hookup of low loss refriger- ant gauges (❑), and access to the service valve caps for opening. For applications with long -line lengths up to 250 feet total equivalent length, up to 200 feet heat pump above evapo- rator, or up to 80 feet evaporator above heat pump, the long -line instructions in the installation manual should be followed. M Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the industry's largest 15" wide and 14" tall control area (®). With all this room in the control area the high voltage electrical whip (❑s ) can easily be inserted through the right size opening in the bot- tom of the control area. Routing it leads directly to contractor lugs for connection. The low voltage control wires (10) are easily connected to units low voltage wiring. If contactor, defrost con- trol or capacitor (11) needs to be replaced there is more than adequate space to make the repair. Furthermore, the service window (12) can be removed to access the TXV and reversing valve by removing two screws or the entire corner can be removed providing ultimate access to the TXV or reversing valve. (18 ) ,t If in the rare event, greater access is needed to internal compo- nents, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprece- dented access to interior of the unit (14 ). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit (15 ). Outdoor coils heights range from as short as 25" to 45", aiding access to the compressor. Disassembly to this degree and com- plete reassembly only takes a first time service technician less than 10 minutes. (is ) 16 18 0 14 15 All units utilize strong formed louver panels which provide indus- try leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan (17 ). All RP15 units utilize single row coils (is) making cleaning easy and complete, restoring the performance of the heat pump back to out of the box perfor- mance levels year after year. 17 The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails. Each cabinet has optimized composite (is) fan orifice assuring efficient and quiet airflow. If in the rare event, greater access is needed to internal compo- nents, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprece- dented access to interior of the unit (14 ). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit (15 ). Outdoor coils heights range from as short as 25" to 45", aiding access to the compressor. Disassembly to this degree and com- plete reassembly only takes a first time service technician less than 10 minutes. (is ) 16 18 0 14 15 All units utilize strong formed louver panels which provide indus- try leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan (17 ). All RP15 units utilize single row coils (is) making cleaning easy and complete, restoring the performance of the heat pump back to out of the box perfor- mance levels year after year. 17 The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails. Each cabinet has optimized composite (is) fan orifice assuring efficient and quiet airflow. Features & Benefits RP15 Series The entire cabinet has powder post paint (20) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life. Scroll compressors with standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product. All RP15 Heat Pumps come standard with high and low pressure switches. Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system. i All cabinets have industry leading structural strength due to the composite base pan (21 ), interlocking corner post (22) formed curved louver panels (2s) and drawn top cover (24) making it the most durable cabinet on the market today. Each RP15 capacity has undergone rigorous psychro- metric testing to assure performance ratings of ut cUS NZ/capacity, SEER, EER and HSPF per AHRI Standard LISTED 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards Each unit has undergone specific strain and modal testing to assure tubing (25) is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation or shut down forces imposed by the compressor. All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A -weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 9). Each unit has been ran in cooling operation at 95°F and 47°F and sound ratings for the RP15 range from as low as 73 dBA to 79 dBA. All units have been ship tested to assure units meet stringent "over the road" shipping conditions. As manufactured all units in the RP15 family have cooling capa- bility to 55 'F. Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component utilization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled, each units' complete refrigerant system is helium leak tested. All units are fully charged from the factory for up to 15 feet of pip- ing. All units are factory run tested. The RP15 has a 10-year conditional compressor and parts warranty (registration required). Optional Accessories (Refer to accessory chart for model #) Compressor Crankcase Heater • Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover • Reinforced vinyl compressor cover containing a 11/2 inch thick batt of fiberglass insulation • Open edges are sealed with a one -inch wide hook and loop fastening tape Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor • In conditions such as low voltage, this kit may be required to increase the compressor starting torque Low Ambient Kit • Heat Pump operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls • Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode • Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 311/611/1 2" • Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture 0o -.1Q Nm_ R P 15 24 A J 1 N A c z CD z= m' Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Option N ,� Category BTU/HR Series** CodeCD Q Ruud P - Heat Pump 15 -15 SEER 18 - 18,000 [5.28 kW] A -1st Design J -1 ph, 208-230/60 1 - Single -stage C - Communicating A -1st Design N/A 24 - 24,000 [7.03 kW] B - 2nd Design C - 3ph, 208-230/60 V - Inverter N - Non -communicating B - 2nd Design 30 - 30,000 [8.79 kW] C - 3rd Design D - 3ph, 460/60 P - Piston. 36 - 36,000 [10.55 kW] ° 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] ConditionersAir Reference) R A 14 24 A J 1 N A Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Code Category BTU/HR [kW] Ruud A - Air Conditioners 13 - 13 SEER 18 - 18,000 [5.28 kW] A - 1st Design J - 1 ph, 208-230/60 1 - Single -stage C - Communicating A - 1st Design N/A 14 - 14 SEER 24 - 24,000 [7.03 kW] B - 2nd Design C - 3ph, 208-230/60 2 - Two -stage N - Non -communicating B - 2nd Design 16 - 16 SEER 30 - 30,000 [8.79 kW] D - 3ph, 460/60 V - Inverter 17 - 17 SEER 36 - 36,000 [10.55 kW] 20 - 20 SEER 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] R C F 24 17 S T A M C A Brand Product Type Capacity Width Efficiency Metering Major Series* Orientation Casing Minor Series** Option Category BTU/HR Device Code Ruud C - Evap Coil F - Furn Coil 24 - 24,000 [7.03 kW] 14 - 14" S- Standard Eff. T-TXV A -1 st Design M - Multi -poise C - Cased A - 1 st Design N/A H - Air -Handler Coil 36 - 36,000 [10.55 kW] 17 - 17.5" M- Mid Eff. E-EEV U - Uncased B - 2nd Design 48 - 48,000 [14.07 kW] 21 - 21" H- High Eff. P-Piston 60 - 60,000 [17.58 kW] 24 - 24.5" [ ] Designates Metric Conversions U 96 V A Brand Series Motor Major Rev Ruud 92 - 92 AFUE V - Variable A - 1 st Design 95 - 95 AFUE speed B - 2nd Design 96 - 96 AFUE T - Constant 97 - 97 AFUE Torque 98 - 98 AFUE (X-1 3) 70 Input BTU/HR [kW] 040 - 42,000 [12.31 kW] 060 - 56,000 [16.41 kW] 070 - 70,000 [20.51 kW] 085 - 84,000 [24.62 kW] 100 - 98,000 [28.72 kW] 115 - 112,000 [32.82 kW] 2 3 17 M Stages Air Flow Cabinet Configuration Width 1 - Single -stage 3 - up to 3 ton 14 - 14" M - Multi -poise 2 - Two -stage 5 - 3 1/2 up to 5 ton 17 - 17.5" U - Upflow M- Modulating 21 - 21" K - Downflow 24 - 24.5" U 80 2 V A 075 3 17 M Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration BTU/HR [kW] Width Ruud 80 - 80+ AFUE 1 Single -stage V - Variable speed A - 1st Design 050 - 50,000 [15 kW] 3 - up to 3 ton 14 - 14" M - Multi 2 Two -stage T - Constant Torque (X-1 3) B - 2nd Design 075 - 75,000 [22 kW] 4 - 2 1/2 to 4 ton 17 - 17.5" D - Down 100 - 100,000 [29 kW] 5 - 3 1/2 up to 5 ton 21 - 21" Z - Down & 125 - 125,000 [37 kW] 24 - 24.5" zero clearance 150 - 150,000 [44 kW] down flow S A NOx Minor Rev X - Low NOx A - 1st Design S - Standard B - 2nd Design S A NOx Minor Rev X - Low NOx A - 1st S - Standard Design B - 2nd Design R H 1 T 36 17 S T A N A A 000 Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Series* Controls Voltage Minor Factory Option Category Airflow BTU/HR Device Series** Heat Cap Code Ruud H - Air Handler 1 - Single -stage V - Variable Speed 24 - 24,000 [7.03 kW] 14 - 14" S - Standard Efficiency T - TEV A -1st Design C - Communicating A - 1 ph, 115/60 A -1 st 00 - no N/A 2 - Two -stage T - Constant Torque 36 - 36,000 [10.55 kW] 17 - 17.5" M -Mid Efficiency E - EEV B - 2nd Design N - Non -communicating J - 1 ph, 208-240/60 Design factory M - Modulating P - PSC 48 - 48,000 [14.07 kW] 21 - 21" H - High Efficiency P - Piston D - 3ph, 480/60 B - 2nd heat with 60 - 60,000 [17.58 kW] 24 - 24.5" Design option code [ ] Designates Metric Conversions mg M O 1Q NN_ NZ m r_ m' =i N rr N z Q CD 7 c7 Physical Data/Electrical Data RP15 Series Physical Data ModelNo.# RP1518 RP1524 RP1530 RP1536 RP1542 RP1548 RP1560 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D. - in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant (R410A) furnished oz.' 123 105 116 118 192 188 217 Compressor Type Scroll Outdoor Coil Net face area - Outer Coil ft2 11.1 11.1 17.3 19.8 24.2 24.2 28.3 Net face area - Inner Coil - - - - - - - Tube diameter- in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 20 20 20 20 20 20 20 Outdoor Fan Diameter - in. 20 20 24 24 24 26 26 Number of blades 2 3 3 3 3 3 3 Motor hp 1/8 1/8 1/5 1/3 1/5 1/3 1/5 CFM 2478 2478 3850 3121 4900 4380 3655 RPM 1077 1075 825 910 825 870 850 watts 151 138 197 134 201 266 274 Shipping weight - Ibs. 159 159 198 206 264 264 285 Operating weight - Ibs. 152 152 191 199 257 257 278 Electrical Data Line Voltage Data (Volts -Phase -Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1 60 Maximum overcurrent protection (amps)2 20/20 25 25 35 45 40 50 Minimum circuit ampacity3 12/12 15 18 23 27 26 31 Compressor Rated load amps 1 9/9 1 10.9 1 12.8 15.4 18.6 18.5 23.7 Locked rotor amps 1 48.0 1 62.9 1 67.8 1 83.9 109 1 124 1 152.5 Condenser Fan Motor Full load amps 0.75 0.7 1 2.8 1 2.8 1 Locked rotor amps 1.3 1.3 - 1.2 - 2.3 Line Voltage Data (Volts -Phase -Hz) - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection (amps)2 71.2 25 31 30 35 Minimum circuit ampacity3 16 19 21 21 Compressor Rated load amps - - 10.4 12.5 1 13.8 1 15.9 Locked rotor amps 73 84 1 83.1 1 110 Condenser Fan Motor Full load amps - - 2.8 1 1 1 2.8 1 1 Locked rotor amps - - - 1 1.2 1 - 1 2.3 'Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 313efer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Accessories/Weighted Sound Power RP15 Series Accessories Model No. RP1518 RP1524 RP1530 RP1536 RP1542 RP1548 RP1560 Compressor crankcase heater 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 Factory Standard Factory Standard Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al SK-Al Low pressure control' Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard High pressure control' Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Liquid Line Solenoid (24 VAC, 50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Bi-flow kit` KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Solenoid Coil 61-AMG120/240V 61 -AMG1 20/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Bi-flow kit` KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 KS30387 Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 Heat Pump Riser-6 inch 686020 686020 686020 686020 1 686020 686020 686020 'Bi-flow kits are required when installing a liquid line solenoid on a heat pump. Weighted Sound Power Level (dBA) Unit Size -Voltage, Series Standard Rating (dBA) TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 125 250 500 1000 2000 4000 8000 RP1518 76.4 53.7 61.8 66.2 66.8 62.9 58 52 RP1524 76.4 53.7 61.3 66.2 66.8 62.9 58 52 RP1530 75.3 53.2 55.4 64.3 65.6 63.1 59.2 57 RP1536 74.7 48.9 54.3 63.1 66.4 62.2 55.2 53.2 RP1542 73.0 49.3 55.3 65.1 60.6 57.9 55.2 48.3 RP1548 76.5 55.8 59 68.2 66.3 64.3 60.5 55.4 RP1560 73.9 58.9 55.7 63.4 63.3 61.5 58.6 56.4 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) Unit Dimensions R1315 Series Unit Dimensions MODEL NUMBER OPERATING SHIPPING H (Height) L (Length) W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RP1518 25 635 29.75 755 29.75 755 26.50 673 32.38 822 32.38 822 RP1524 25 635 29.75 755 29.75 755 26.50 673 32.38 822 32.38 822 RP1530 31 787 33.75 857 33.75 857 32.50 826 36.38 924 36.38 924 RP1536 35 889 33.75 857 33.75 857 36.50 927 36.38 924 36.38 924 RP1542 39 991 35.75 908 35.75 908 40.50 1029 38.38 975 38.38 975 RP1548 39 991 35.75 908 35.75 908 40.75 1035 38.38 975 38.38 975 RP1560 45 1143 35.75 908 35.75 908 46.75 1187 38.38 975 38.38 975 ALLOW 60" [1524 mm] OF CLEARANCE Z;E PANELS/ CONNECTIONS / HIGH & LOW GE ACCESS ✓ 24" [610 mm] OF CLEARANCE 6" [152 mm] MIN. OF CLEARANCE ALL SIDES 12" [305 mm] RECOMMENDED [ ] Designates Metric Conversions ST-A1226-02-00 CLEARANCES WALL 6" (152.4) 24° 12" (609.6) (304.8) Service 6" (152.4) WALL 12" (304.8) 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18" 24" 24" (457.2) (609.6) (609.6) 24" recommended 24" recommended 9" minimum 9" minimum NOTE: NUMBERS IN () = mm IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re -circulation of discharge air. M 0 � y Ln y ST-A1225-01-00 f!) z m ED' cn N Wiring Diagram/Application Guidelines RP15 Series Control Wiring FIGURE 4 CONTROL WIRING FOR AIR HANDLER WIRING INFORMATION Line Voltage -Field Installed— — — - -Factory Standard Heat Pump Thermostat TYPICAL THERMOSTAT: QQ O O Q Q HEAT PUMP H ELECTRIC HEAT Heat Pump -------y--r-' ' Outdoor Unit I" r -�- - r - - - - - - - - - - - Y r , r r l------- B ' C ' r r1 r r 1 D 1 - - - - - - - - - - - - - - - - - ' L. - - ' ' ' •-------------------------------- -, 1 NOTE: RED WIRE REQUIRED WITH RANCID DDL DEMAND DEFROST CONTROL. NOTES: 1. Jumper "E" to "W2" to transfer control of supplemental heat to 1 st stage when the emergency heat switch is on. 2. This wire turns on heat for defrost, omit for most economical operation. 3. Wire with colored tracing stripe. Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operation air temperature for cooling mode without low -ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory - supplied filter drier must be installed. Table 2A: Refrigerant Line Sizing Chart (English Units) 15 SEER Single -Stage Heat Pumps Unit Size Allowable Liquid Line Size Allowable Vapor Line Size Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Feet) < 25 26-50 51-75 76-100 1 101-125 1 126-150 1 151-175 176-200 201-225 226-250 (-)P15 Maximum Vertical Separation / Capacity Multiplier 1/4" 5/8" 98 25 / 1.00 50 / 0.99 62 / 0.98 43 / 0.98 24 / 0.97 5 / 0.97 N/R /R N/ N/R 5/16" 5/8" 78 25 / 1.00 50 / 0.99 75 / 0.98 98 / 0.98 93 / 0.97 88 / 0.97 83 / 0.96 78 / 0.96 73 / 0.95 68 / 0.94 1.5 Ton' 3/8" 5/8" 57 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96 100 / 0.95 100 / 0.94 SEE NOTE 3 1/4" 3/4"' 98 25 / 1.00 50 / 1.00 62 / 0.99 43 / 0.99 24 / 0.99 5 / 0.99 R N/R N/R N/R 5/16" 3/4"' 78 25 / 1.00 50 / 1.00 75 / 0.99 98 / 0.99 93 / 0.99 88 / 0.99 83 / 0.99 78 / 0.98 73 / 0.98 68 / 0.98 3/8" 3/4"" 57 25 / 1.00 50 / 1.00 75 / 1.00 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 100 / 0.98 100 / 0.98 1/4" 5/8" N/A 25 / 0.99 50 / 0.98 21 / 0.97 N N/R N/R N/R N/R N/R N/R 5/16" 5/8" 123 25 / 0.99 50 / 0.98 75 / 0.97 87 / 0.96 77 / 0.95 69 / 0.94 61 / 0.93 53 / 0.92 45 / 0.91 37 / 0.90 2 Ton 3/8" 5/8" 82 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 98 / 0.93 95 / 0.92 93 / 0.91 90 / 0.90 1/4" 3/4" N/A 25 /1.00 50 / 1.00 21 / 0.99 N/R N/R N/R N/R N/R N/R N/R 5/16" 3/4" 123 25 /1.00 50 / 1.00 75 / 0.99 87 / 0.99 77 / 0.98 69 / 0.98 61 / 0.98 53 / 0.97 45 / 0.97 37 / 0.96 3/8" 3/4" 82 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.98 100 / 0.98 98 / 0.98 95 / 0.97 93 / 0.97 90 / 0.96 5/16" 5/8" 103 25 / 0.99 50 / 0.98 75 / 0.96 70 / 0.94 59 / 0.93 48 / 0.91 36 / 0.90 N/R N/R N/R 2.5 Ton 3/8" 5/8" 68 25 / 0.99 50 / 0.98 75 / 0.96 100 / 0.94 98 / 0.93 94 / 0.91 90 / 0.90 N/R N/R N/R 5/16" 3/4" 103 25 / 1.00 50 / 0.99 75 / 0.99 70 / 0.98 59 / 0.98 48 / 0.97 36 / 0.96 25 / 0.96 13 / 0.95 N/R 3/8" 3/4" 68 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 98 / 0.98 94 / 0.97 90 / 0.96 86 / 0.96 82 / 0.95 78 / 0.95 5/16" 5/8" 98 25 / 0.99 50 / 0.97 66 / 0.94 49 / 0.92 32 / 0.90 N/R N/R N/R N/R N/R 3/8" 5/8" 65 25 / 0.99 50 / 0.97 75 / 0.94 95 / 0.92 89 / 0.90 N/R N/R N/R N/R N/R 5/16" 3/4" 98 25 / 1.00 50 / 0.99 66 / 0.98 49 / 0.98 32 / 0.97 15 / 0.96 N/R N/R N/R N/R 3 Ton 3/8" 3/4" 65 25 / 1.00 50 / 0.99 75 / 0.98 95 / 0.98 89 / 0.97 84 / 0.96 78 / 0.95 72 / 0.94 67 / 0.93 61 / 0.93 1 /2" 3/4" 33 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.98 100 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.93 100 / 0.93 5/16" 7/8" 98 25 / 1.00 50 / 1.00 66 / 1.00 49 / 0.99 32 / 0.99 15 / 0.99 r N/R N/R N/R N/R 3/8" 7/8" 65 25 / 1.00 50 / 1.00 75 / 1.00 95 / 0.99 89 / 0.99 84 / 0.99 78 / 0.98 72 / 0.98 67 / 0.98 61 / 0.97 1/2" 7/8" 33 25 / 1.00 50 / 1.00 1 75 / 1.00 100 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 1 100 / 0.98 100 / 0.98 100 / 0.97 3/8" 3/4" 93 25 / 0.99 50 / 0.98 75 / 0.97 88 / 0.96 80 / 0.95 72 / 0.94 65 / 0.92 57 / 0.91 49 / 0.90 N/R Ton 1 /2" 3/4" 47 25 / 0.99 50 / 0.98 75 / 0.97 100 / 0.96 100 / 0.95 100 / 0.94 100 / 0.92 100 / 0.91 100 / 0.90 N/R 3.5 3/8" 7/8" 93 25 / 1.00 50 / 1.00 75 / 0.99 88 / 0.99 80 / 0.99 72 / 0.98 65 / 0.97 57 / 0.97 49 / 0.96 42 / 0.96 1 /2" 7/8" 47 25 / 1.00 50 / 1.00 75 / 0.99 100 / 0.99 100 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96 Notes: 1) Do not exceed 200 ft linear line length. 2) Do not exceed 100 ft vertical separation between indoor and outdoor units. 3) `3/4" vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction line pressure drop. vCD I3 cn (8. mw CD m m Table 2A: Refrigerant Line Sizing Chart (English Units) (con't.) 15 SEER Single -Stage Heat Pumps Unit Size Allowable Liquid Line Size Allowable Vapor Line Size Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Feet) <25 26-50 51-75 76-100 1 101-125 1 126-150 1 151-175 1 176-200 201-225 1 226-250 ( )P15 Maximum Vertical Separation / Capacity Multiplier 3/8" 3/4" 0 25 / 0.99 50 / 0.98 75 / 0.96 77 / 0.95 67 / 0.93 57 / 0.92 46 / 0.91 N/R N/R N/R 4 Ton 1/2" 3/4" 0 25 / 0.99 50 / 0.98 75 / 0.96 100 / 0.95 100 / 0.93 100 / 0.92 100 / 0.91 N/R N/R N/R 3/8" 7/8" 0 25 / 1.00 50 / 0.99 75 / 0.99 77 / 0.98 67 / 0.97 57 / 0.97 46 / 0.96 36 / 0.96 26 / 0.95 15 / 0.95 1/2" 7/8" 0 25 / 1.00 50 / 0.99 75 / 0.99 100 / 0.98 100 / 0.97 100 / 0.97 100 / 0.96 100 / 0.96 99 / 0.95 97 / 0.95 3/8" 3/4" 0 25 / 0.99 50 / 0.97 75 / 0.94 61 / 0.92 46 / 0.90 N/R N/R N/R N/R N/R 1/2" 3/4" 0 25 / 0.99 50 / 0.97 75 / 0.94 100 / 0.92 100 / 0.90 k N/R N/R N/R N/R N/R 5 Ton 3/8" 7/8" 0 25 / 1.00 50 / 0.99 75 / 0.98 61 / 0.97 46 / 0.96 32 / 0.95 18 / 0.94 N/R N/R N/R 1/2" 7/8" 0 25 / 1.00 50 / 0.99 75 / 0.98 100 / 0.97 100 /0.96 100 / 0.95 97 / 0.94 95 / 0.94 92 / 0.93 89 / 0.92 3/8" 1-1 /8" 0 25 / 1.01 50 / 1.01 75 / 1.00 61 / 1.00 46 / 0.99 32 / 0.99 18 / 0.99 N/R N/R N/R 1/2" 1-1 /8" 0 25 / 1.01 50 / 1.01 75 / 1.00 100 /1.00 100 / 0.99 100/0.99 97 / 0.99 95 / 0.99 92 / 0.99 89 / 0.98 Notes: 1) Do not exceed 200 ft linear line length. 2) Do not exceed 100 ft vertical separation between indoor and outdoor units. 3)'3/4" vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction line pressure drop. L,t. rn m m CD m m Table 213: Refrigerant Line Sizing Chart (Metric Units) 15 SEER Single -Stage Heat Pumps Unit Size Allowable Liquid Line Size mm [in.] Allowable Vapor Line Size man [in] Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters) < 8 8-15 16-23 24-30 31-38 1 39-46 47-53 54-61 62-69 70-76 ()P15 Maximum Vertical Separation / Capacity Multiplier 6.35 [1/4] 15.88 [5/8] 30 8 / 1.00 15 / 0.99 19 / 0.98 13 / 0.98 7 / 0.97 2 / 0.97 RWIR N/R N/R N/R 5.3 kW 7.94 [5/16] 15.88 [5/8] 24 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 28 / 0.97 27 / 0.97 25/0.96 24/0.96 22 / 0.95 21 / 0.94 [1.5 Ton] 9.53 [3/8] 15.88 [5/8] 17 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30 / 0.97 30/0.96 30/0.96 30 / 0.95 30 / 0.94 *SEE 6.35 [1/4] 19.05 [3/4]" 30 8 / 1.00 15 / 1.00 19 / 0.99 13 / 0.99 7 / 0.99 2 / 0.99 N/R N/R N/ N/R NOTE 3 7.94 [5/16] 19.05 [3/4]" 24 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 28 / 0.99 27 / 0.99 25 / 0.99 24 / 0.98 22 / 0.98 21 / 0.98 9.53 [3/8] 19.05 [3/4]" 17 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 6.35 [1/4] 15.88 [5/8] N/A 8 / 0.99 15 / 0.98 6 / 0.97 N/R N/R N/R N/R N/R N/R N/R 7.94 [5/16] 15.88 [5/8] 37 8 / 0.99 15 / 0.98 23 / 0.97 27 / 0.96 23 / 0.95 21 / 0.94 19 / 0.93 16 / 0.92 14 / 0.91 11 / 0.90 7.0 kW 9.53 [3/8] 15.88 [5/8] 25 8 / 0.99 15 / 0.98 23 / 0.97 30/0.96 30 / 0.95 30 / 0.94 30 / 0.93 29 / 0.92 28 / 0.91 27 / 0.90 [2 Ton] 6.35 [1/4] 19.05 [3/4] N/A 8 / 1.00 15 / 1.00 6 / 0.99 66 N/R jL N/R N/R N/R N/R N/R N/R 7.94 [5/16] 19.05 [3/4] 37 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 23 / 0.98 21 / 0.98 19 / 0.98 16 / 0.97 14 / 0.97 11 / 0.96 9.53 [3/8] 19.05 [3/4] 25 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 29 / 0.97 28 / 0.97 27 / 0.96 7.94 [5/16] 15.88 [5/8] 31 8 / 0.99 15 / 0.98 23 / 0.96 21 / 0.94 18 / 0.93 15 / 0.91 11 / 0.90 N/R N/R N/R 8.8 kW 9.53 [3/8] 15.88 [5/8] 21 8 / 0.99 15 / 0.98 23 / 0.96 30 / 0.94 30 / 0.93 29 / 0.91 27 / 0.90 N/R N/R N/R [2.5 Ton] 7.94 [5/16] 19.05 [3/4] 31 8 / 1.00 15 / 0.99 23 / 0.99 21 / 0.98 18 / 0.98 15 / 0.97 11 / 0.96 8/0.96 4 / 0.95 N/R 9.53 [3/8] 19.05 [3/4] 21 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.98 29 / 0.97 27 / 0.96 26/0.96 25 / 0.95 24 / 0.95 7.94 [5/16] 15.88 [5/8] 30 8 / 0.99 15 / 0.97 20 / 0.94 15 / 0.92 10 / 0.90 N/R N/R N/R N/R N/R 9.53 [3/8] 15.88 [5/8] 20 8 / 0.99 15 / 0.97 23 / 0.94 29 / 0.92 27 / 0.90 N/R N/R N/R N/R N/R 7.94 [5/16] 19.05 [3/4] 30 8 / 1.00 15 / 0.99 20 / 0.98 15 / 0.98 10 / 0.97 5/0.96 N/R N/R N/R N/R 10.6 kW 9.53 [3/8] 19.05 [3/4] 20 8 / 1.00 15 / 0.99 23 / 0.98 29 / 0.98 27 / 0.97 26 / 0.96 24 / 0.95 22 / 0.94 20 / 0.93 19 / 0.93 [3 Ton] 12.7 [1/2) 19.05 [3/4] 10 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.98 30 / 0.97 30/0.96 30 / 0.95 30 / 0.94 30 / 0.93 30 / 0.93 7.94 [5/16] 22.23 [7/8] 30 8 / 1.00 15 / 1.00 20 / 1.00 15 / 0.99 10 / 0.99 5 / 0.99 N/R N/R N/R N/R 9.53 [3/8] 22.23 [7/8] 20 8 / 1.00 15 / 1.00 23 / 1.00 29 / 0.99 27 / 0.99 26 / 0.99 24 / 0.98 22 / 0.98 20 / 0.98 19 / 0.97 1/2 [12.7] 22.23 [7/8] 10 8 / 1.00 15 / 1.00 23 / 1.00 30 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.98 30 / 0.98 30 / 0.97 9.53 [3/8] 19.05 [3/4] 28 8 / 0.99 15 / 0.98 23 / 0.97 27 / 0.96 24 / 0.95 22 / 0.94 20 / 0.92 17 / 0.91 15 / 0.90 N/R 12.3 kW 12.7 [1/2] 19.05 [3/4] 14 8 / 0.99 15 / 0.98 23 / 0.97 30/0.96 30 / 0.95 30 / 0.94 30 / 0.92 30 / 0.91 30 / 0.90 N/R [3.5 Ton] 9.53 [3/8] 22.23 [7/8] 28 8 / 1.00 15 / 1.00 23 / 0.99 27 / 0.99 24 / 0.99 22 / 0.98 20 / 0.97 17 / 0.97 15 / 0.96 13 / 0.96 12.7 [1/2] 22.23 [7/8] 14 8 / 1.00 15 / 1.00 23 / 0.99 30 / 0.99 30 / 0.99 30 / 0.98 30 / 0.97 30 / 0.97 30/0.96 30 / 0.96 Notes: 1) Do not exceed 61 meters linear line length. 2) Do not exceed 30 meters vertical separation between indoor and outdoor units. 3) *19.05mm [3/4 in.] vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction line pressure drop. wCD CD a) m'Ir m m Table 213: Refrigerant Line Sizing Chart (Metric Units) (con't.) 15 SEER Single -Stage Heat Pumps Unit Size Allowable Liquid Line Size mm [in.] Allowable Vapor Line Size mm [in] Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters) < 8 8-15 16-23 24-30 31-38 1 39-46 47-53 54-61 62-69 70-76 (-)P14-F Maximum Vertical Separation / Capacity Multiplier 9.53 [3/8] 19.05 [3/4] 0 8 / 0.99 15 / 0.98 23 / 0.96 24 / 0.95 20 / 0.93 17 / 0.92 14 / 0.91 N/R N/R N/R 14.1 kW 12.7 [1/2] 19.05 [3/4] 0 8 / 0.99 15 / 0.98 23 / 0.96 30 / 0.95 30 / 0.93 30 / 0.92 30 / 0.91 N/R N/R N/R [4 Ton] 9.53 [3/8] 22.23 [7/8] 0 8 / 1.00 15 / 0.99 23 / 0.99 24 / 0.98 20 / 0.97 17 / 0.97 14 / 0.96 11 / 0.96 8 / 0.95 5 / 0.95 12.7 [1/2] 22.23 [7/8] 0 8 / 1.00 15 / 0.99 23 / 0.99 30 / 0.98 30 / 0.97 30 / 0.97 30 / 0.96 30 / 0.96 30 / 0.95 30 / 0.95 9.53 [3/8] 19.05 [3/4] 0 8 / 0.99 15 / 0.97 23 / 0.94 19 / 0.92 14 / 0.9070.99 /R N/R N/R N/R N/R 12.7 [1/2] 19.05 [3/4] 0 8 / 0.99 15 / 0.97 23 / 0.94 30 / 0.92 30 / 0.90/R N/R N/R N/R N/R 17.6 kW 9.53 [3/8] 22.23 [7/8] 0 8 / 1.00 15 / 0.99 23 / 0.98 19 / 0.97 14 / 0.96 0.95 5 / 0.94 N/R N/R N/R [5 Ton] 12.7 [1/2] 22.23 [7/8] 0 8 / 1.00 15 / 0.99 23 / 0.98 30 / 0.97 30 /0.96 0.95 30 / 0.94 29 / 0.94 28 / 0.93 27 / 0.92 9.53 [3/8] 28.58 [1-1/8] 0 8 / 1.01 15 / 1.01 23 / 1.00 19 / 1.00 14 / 0.99 0.99 5 / 0.99 N/R N/R N/R 12.7 [1/2] 28.58 [1-1/8] 0 8 / 1.01 15 / 1.01 23 / 1.00 30 / 1.00 30 / 0.99 30 / 0.99 29 / 0.99 28 / 0.99 27 / 0.98 Notes: 1) Do not exceed 61 meters linear line length. 2) Do not exceed 30 meters vertical separation between indoor and outdoor units. 3)'19.05mm [3/4 in.] vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) Always use the smallest liquid line allowable to minimize refrigerant charge. 5) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction line pressure drop. L,t. mCD m 'm CD m m Performance Data @ AHRI Standard Conditions - Heat Pump Designated Tested Combination (DTC) Outdoor Unit Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] 47 Degree Heating Capacity BTU/H [kW] 47 Degree COP 17 Degree Heating Capacity BTU/H [kW] 17 Degree COP Region IV HSPF RP1518CJ1 RH1T2417STAN 18000 [5.27] 14400 [4.22] 3600 [1.0] 15.00 12.50 650 [305.0] 15700 [4.60] 3.60 9100 [2.7] 2.40 8.20 RP1524BJ1 RH1T2417STAN 24000 [7.0] 16900 [5.0] 7100 [2.1] 15.50 13.00 800 [376.0] 22000 [6.4] 3.70 13500 [4.0] 2.50 9.00 RP153013J1 RH1T3617STAN 29400 [8.6] 20800 [6.1] 8600 [2.5] 15.50 13.00 1025 [481.8] 27000 [7.9] 3.70 16600 [4.9] 2.40 9.00 RP1536AJ1 RH1T3617STAN 35600 [10.4] 25100 [7.4] 10500 [3.1] 15.00 12.50 1175 [552.3] 33800 [9.9] 3.66 22200 [6.5] 2.66 9.00 RP1542AC1 RH1T4821STAN 42500 [12.5] 30000 [8.8] 12500 [3.7] 15.00 12.50 1350 [634.5] 40000 [11.7] 3.76 25600 [7.5] 2.60 9.00 RP1542AJ1 RH1T4821STAN 42500 [12.5] 30000 [8.8] 12500 [3.7] 15.00 12.50 1350 [634.5] 40000 [11.7] 3.76 25600 [7.5] 2.60 9.00 RP1548AC1 RH1T4821STAN 47000 [13.8] 33200 [9.7] 13800 [4.0] 15.00 12.50 1500 [705.0] 44500 [13.0] 3.66 28800 [8.4] 2.60 9.00 RP1548AJ1 RH1T4821STAN 47000 [13.8] 33200 [9.7] 13800 [4.0] 15.00 12.50 1500 [705.0] 44500 [13.0] 3.66 28800 [8.4] 2.60 9.00 RP1560AC1 RH1T6024STAN 58000 [17.0] 41000 [12.0] 17000 [5.0] 15.00 12.50 1775 [834.3] 56000 [16.4] 3.76 35600 [10.4] 2.66 9.00 RP1560AJ1 RH1T6024STAN 58000 [17.0] 41000 [12.0] 17000 [5.0] 15.00 12.50 1775 [834.3] 56000 [16.4] 3.76 35600 [10.4] 2.66 9.00 Note: Additional ratings and system match ups can be accessed on My.Ruud.com at: hftps:Hmy.ruud.com/static/private/ahriresidential.html Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org [ ] Designates Metric Conversions My vCD �3 cn o En m a) m o N CD Guide Specifications RP15 Series GUIDE SPECIFICATIONS General System Description Outdoor -mounted, air-cooled, split -system heat pump unit suit- able for ground or rooftop installation. Unit consists of a hermetic compressor, composite basepan, an air-cooled coil, propeller - type condenser fan, suction and liquid line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding ASTM B117 1000- hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. Products Equipment Factory assembled, single piece, air-cooled heat pump unit. Con- tained within the unit enclosure is all factory wiring, piping, con- trols, compressor, refrigerant charge R-410A, and special fea- tures required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonder- ized, and coated with a powder coat paint. — All units constructed with louver coil protection and corner post. Louver can be removed by removing one fastener per louver panel. AIR-COOLED, SPLIT -SYSTEM HEAT PUMP RP15 1-1/2 TO 5 NOMINAL TONS Fans — Condenser fan will be direct -drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes. Refrigeration Components — Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of R-410A refrigerant, and compressor oil. — Unit will be equipped with filter drier for R-410A refrigerant for field installation. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evap- orator at °F/°C wet bulb and °F/°C dry bulb, and air entering the unit at °F/°C. — The system will have a SEER of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Nominal unit electrical characteristics will be _ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Limited Warranty RP15 Series GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts (Registration Required) Ten (10) Years In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating 5600 Old Greenwood Road Ruud Canada • 125 Edgeware Road, Unit 1 Fort Smith, Arkansas 72908 www.ruud.com Brampton, Ontario • L6Y OP5 PRINTED IN U.S.A. 4/20 QG FORM NO. P22-807 REV. 11