Loading...
APPROVED ENG2025-0089 ROW PERMITRIGHT OF WAY EUC PERMIT PERMIT City of Edmonds J :01 008 www.edmondswa.gov i Description: PUD - REPLACE 1 BO POLE ISSUED: 03/20/2025 Address: 180 2ND AVE S EDMONDS WA 98020 EXPIRES: 09/16/2025 rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 27032300409000 I 11-14111 a i i NAME TYPE NAME ADDRESS PHONE APPLICANT MOE MATTHEWS PO BOX 1107, EVERETT WA 98206 (425)783-1000 CONTACT SNOHOMISH COUNTY PUD PO BOX 1107, EVERETT WA 98206 (425)239-8210 CONTRACTOR SNOHOMISH COUNTY PUD PO BOX 1107, EVERETT WA 98206 (425)783-4353 OWNER WELLTOWER LANDLORD GROUP LLC 4500 DORR ST, TOLEDO OH 43615 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $49.00 $49.00 ENG - INSPECTIONS-1.1.25 $548.00 $548.00 ROW - STANDARD - 1.1.25 $411.00 $411.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 03/20/2025 Printed: Thursday, March 20, 2025 2:28:50 PM 1 of 2 RIGHT OF WAY EUC PERMIT PERMIT NUMBE3 City of Edmonds www.edmondswa.gov • • CONDITIONS CONDITION TYPE ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL** E-7 RESTOR LIMITS Printed: Thursday, March 20, 2025 2:28:50 PM 2 of 2 of EVAJC) RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal "'VC. i oo Requirements outlined in Right -of -Way permit Handout E6�. If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General Info Project Name REPLACE BAD ORDER POLE AND 1100 UG FEEDERS Site Address or if no site address use Property Address at NW corner of project area: Associated Permits: BLD PLN ENG Owner and Entity Holding•• •- Nameof Company SNOHOMISH COUNTY PUD Franchise Ordinance No: N/A Point of Contact ANDREW RIFE Title PROJECT MANAGER III Address 1802 75TH ST SW city EVERETT state WA zip 98203 Phone 425-783-8559 Email ASRIFE SNOPUD.COM Contractor and Authorized Agent of Owner (see note below) Name of Company S N O H O M I S H COUNTY PUD Contractor Contacts During Construction Primary Name Agent Name ANDREW RIFE Title Title PROJECT MANAGER III Mobile Address Email City EVERETT Stat WA I zip98023 Secondary Name Phone 425-783-8559 Title Email ASRIFE SNOPUD.COM& permits@snopud.com Mobile City of Edmonds Business License No: Email State License No: 313-005-741 x Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o.02o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 ❑ Utility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) PUD CREWS WILL SET UP FACING WEST TO REPLACE I -BAD ORDER POLE WITH THE WORK IS ESTIMATED TO TAKE 5 R1 ISINESS DAYS 40 HRS TO COMPI ETE NO TREE WORK AND THERE WILL BE TEMPORARY IMPACT TO PEDESTRIAN TRAFFIC Reapplying tor cancelled 1 1 RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF 5 DAY Alley 72 hours + LF JxJ F SF Parking 72 hours + LF JxJ LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable (power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. 1 Does the utility owner have existing overhead infrastructure in the area of work? Yes No 2. 1 Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? X 5. Does the work involve proposed additions to an aboveground utility system? If es: X Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? W Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more X than one lot or commercial development? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: X 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 3 How many are to be added? 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 1 What is the height of the existing poles? How many poles are to be removed? Are additionalpoles to be laced? NO How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? 1 1 1 What is the height of the poles after? 50 Describe the modification rebuild: LIKE FOR LIKE SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: 4/v2�:)4— "" DATE: 03/03/25 APPLICANT PRINTED NAME: ANDREW RIFE APPLICANT TITLE: PROJECT MANAGER III NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM PUBLIC UTILITY DISTRICT NO.1 OF SNOHOMISH COUNTY LOCATION 180 2nd AVE S LYNNWOODAREA POLE NO. 345 SE1/4S 23 T 27 R 04 DATE 03/27/22 ORDER 100092672 REASON FOR WORK REPLACE BAD ORDER POLE FOR ENGINEER A. RIFE OPERATION 0030 PUD PRI-5 1100 FEEDER POLE DRAFTER U.G. NO. SCALE 1" =100' APPROVED & DATE PRINTED DATE WORK COMPLETED FOREMAN FEES REQ'D o YES ■ NO PRIMARY OVERHEAD O RESIDENTIAL O COMMERCIAL LEO NO. 'as '-i SECONDARY OVERHEAD NESC VIOLATIONS BASIC FEE S ■ NO O YES (SEE NOTES) 'as '=i PERMITS (DATE GRANTED) METER/CONY. POLE = 0 TREE TRIM PRIMARY UNDERGROUND O STATE O RESIDENTIAL O COUNTY DATE SUBSTATION MPL CIRCUIT NO. 12-343 PHASE 123 ENGR'S TEL. • 425-783-8559 ENGR'S CELL • 425-239-8210 OCOMMERCIAL RESTORATION LIMITS TO BE DETERMINED BY CITY ENGINEERING INSPECTOR LEU NO. 'as '=i O REQUIRED ■ NOT REQUIRED SECONDARY UNDERGROUND BASIC FEE S DATE RELEASED 'as 'MS UNDERGROUND PLAT FOREIGN CONTACTS • JPN• 100092672 BASIC FEE S Ct FT.0 'MS O JOINT TRENCH ZIPLY & CATV OJOINT BORE ZIPLY & CATV STREET LIGHTING O q FT.ft 'MS POLE STENCILINGFROM WORK IN RIGHT OF WAY TO O PRIMARY TAKE OFF POLE O SECONDARY PRE-CONST. REQUIRMENTS O TREE TRIM O PUD LOCATOR q FTA% =i MISCELLANEOUS FEES O BACKHOE ■ FLAGGING VAULT S ■ ONE CALL DATE PERMIT S No. f STREET LIGHTING O YES ■ NO = f M&R AS -BUILT S GIS TOTAL DUE S DATE PAID GIS OC M&R GIS Ph JOINT USE RECEIPT NO. LOCATION MAP PAGE 454E-6 SERVICE ORDER NO. CONSTRUCTION NOTES: A LOC A: MAKE 3'X3' CONCRETE CUT AROUND EXISTING POLE PLI-345. SET NEW 50FT CL-1 WOOD POLE IN PLACE FRAME POLE PER CS-12U314A TRANSFER OVHD PRI CONDUCTORS (3)336.4AAC PRI & (1)3/0 NEUT TRANSFER OVHD SEC SVC AND CONNECT TO 1" CUSTOMER OWNED SEC SVC TRANSFER SL-101969-A BUILD NEW 6" PRI/RISER ON W. SIDE OF NEW POLE INTERCEPT EXISTING 6" PVC AT BASE OF POLE FOR 15KV 1100 PRI CONDCUTOR REPLACEMENT. SEE UG*1997-41 AND S2 DRAWINGS ATTACHED! MAKE 3'X3' CONCRETE CUT 20FT W OF NEW POLE FOR ANCHOR SET. INSTL 1-1/2" PRI & 1-1/2" NEUT DG G0114 INSTL 1-12" SINGLE HELIX ANC L=20FT W A0102 RMV POLE 45FT CL-2 WOOD POLE FROM SYSTEM B LOC B: PLI-344 CUT IN DEAD-END INSULATORS 7FT WEST OF ALLEY ARM INSTALL 3-336.4 PRI JUMPERS TO CUT IN AIRBRAKES TO TEMP V) DE -ENERGIZE OH LINE AND U FEED TO WEST. WHEN WORK COMPLETE RMV AIRBRAKES AND SLEEVE EXT 336.6 AAC PRI LLJ Q OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE LEGEND: OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING 0 EXISTING POLE ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY 0 EXISTING POLE -TO BE REMOVED UTILITIES MAY REQUIRE A SEPERATE PERMIT. • NEW POLE )1( NEW POLE TO REPLACE EXISTING POLE (N 65-65-65/12 I 321 I 6 300-319233 O E 43439 SL-129788-A 120609 SL-130538-A 251533 SW 12-1788 SL-10 69-A 45 ---------------- ---------------- ---- -� N.O. SW 12-2678 i n SW 12-2160 A 1963 `1 --------------- -------------- -- ISTA-374657 MPL 2500-16--------7------- -- , I -- - - - --,� A-17626 11 1 x SW 12-,577 1 1 --8 -- T -- ----- � I EV-5747 ' T ! FU150------- 2-67� 250015 SW 12-2676 A-17627-------+----------- A 176 9 1' ! FU150 11-10 6 I 110-M d' E-24976 `----T-� O N.O. SW 12-2674 3 N.O. SW 12-2673_________ 00 �- SW 12-2672 A-11113 = Applicant shall repair/replace all ENGINEERING DIVISION damage to utilities or frontage APPROVED AS NOTED SHEET OF improvements in City right-of-way per city standards that is caused or occurs during the permitted project. JA W41,1,44z 03/20/2025 VV ob IR N 40 N 0 0 is N M 3� siW J~ 4C SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LANE SHIFT ON A TWO—WAY -1 ROAD 7CE WORK AHEAD TER X W20-5MOD LANE CLOSED AH\ EA� X N J m <X� (OPTIONAL) (OPTIONAL) (OPTIONAL) THREE —LANE, ROAD N J N J SIGN SPACING = X FREEWAYS & EXPRESSWAYS 55-70 MPH 1500'± RURAL HIGHWAYS 60-65 MPH 800'± RURAL ROADS 45-55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35-40 MPH 350'± RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 25-30 MPH 200'± (2) URBAN STREETS 1 25 MPH OR LESS 100'± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS ROADWAY CONDITIONS. INTERCHANGE TO FIT TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET' a (OPTIONAL) x \1-4L i N \\\LLL\\\111 J x CENTER i LANE W20-5MOD CLOSED X / \\EAD ROAD i WORK AHEAD W20-1 MINIMUM LANE CLOSURE TAPER LENGTH = L (FEET) LANE WIDTH POSTED SPEED (MPH) (FEET) 25 30 35 1 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 245 320 540 600 660 720 780 840 GENERAL NOTES: 1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD. 2. NOTIFY LOCAL EMERGENCY SERVICES OF CLOSURE TIMES AND DATES (OPTIONAL). 3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD CONDITIONS. 4. PROTECTIVE VEHICLE RECOMMENDED -MAY BE A WORK TRUCK. 5. ALL SIGNS MINIMUM 48" X 48", UNLESS OTHERWISE SPECIFIED. 6. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES. SEE TABLE 1 FOR SPACING DISTANCES. 7. ALL SPACING MAY BE ADJUSTED TO ACCOMODATE AT -GRADE INTERSECTIONS AND/OR DRIVEWAYS. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 1 30 35 40 45 50 55 60 65 1 70 LENGTH (FEET)l 155 1 200 1 250 1 305 360 1 425 1 495 570 1 645 1 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 LBS. HOST VEHICLE WEIGHT > 22,000 LBS. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 1 172' 1 74' 1 100' 1 150' TABLE 1 CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50-70 40 80 35-45 30 60 25-30 1 20 40 PROJECT - LOCATION ENGINEER PHONE CELLULAR LEGEND: CHANNELIZING DEVICE i PORTABLE SIGN AND SUPPORT ®® WORK VEHICLE WITH FLASHING LIGHT WORK AREA DATE ORDER ENGINEERING DIVISION APPROVED AS NOTED %I/ Ul j,1, I44i 03/20/2025 CITY OF EDMONDS M BuildingPermit.com Right -of -Way Application #1621723 - WO 100092672 Applicant First Name Last Name Company Name Moe Matthews Snohomish County PUD Number Street Apartment or Suite Number E-mail Address PO Box 1107 permits@snopud.com City State Zip Phone Number Extension Everett WA 98206 (425) 783-1000 Contractor Company Name Owner Number Street Apartment or Suite Number City State Zip Phone Number Extension State License Number License Expiration Date UBI # E-mail Address Project Location Number Street Floor Number Suite or Room Number 180 2ND AVE S City Zip Code County Parcel Number EDMONDS 98020 27032300409000 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name WELLTOWER LANDLORD GROUP LLC Number Street Apartment or Suite Number 4500 DORR ST City State Zip TOLEDO OH 43615 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 3/4/2025 Submitted By: Moe Matthews Page 1 of 2 i CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1621723 - WO 100092672 Project Contact Company Name: Snohomish County PUD Name: Andy Rife Email: asrife@snopud.com Address: PO Box 1107 Phone #: (425) 239-8210 Everett WA 98206 Project Type Utility Purveyor Activity Type Utility Work Scope of Work Disturbance of Surface Project Name: WO 100092672 WO 100092672: Reapplying for cancelled ENG2022-0143. PUD crews to replace a BO pole Description of (45' to 50', same material) and UG feeder cables. Work to take 5 days @ 40 hours total. Work: There will be two small concrete cuts to replace pole and anchor. No tree trimming or pedestrian impact. Project Details Project Information Job Number WO 100092672 Page 2 of 2