16007 MAD PDF 20170328 Permit Rev 01 Set.pdfREFERENCE SYMBOLS PIPING ELEMENTS/VALVING DUCTWORK SYMBOLS NEW DUCTWORK MATCHLINE ENLARGED PLAN BORDER 18x12 EXISTING MECHANICAL WORK TO BE DEMOLISHED EXISTING MECHANICAL WORK NEW MECHANICAL WORK SECTION IDENTIFIER1 MX.X MX.X 1 DETAIL OR DRAWING IDENTIFIER 1 INDICATES REVISION & NUMBER REVISION CLOUD INDICATES WHERE SECTION APPEARS FLAG NOTE1 AHU-XXX EQUIPMENT IDENTIFIER POINT OF CONNECTION NORTH ARROW MECHANICAL ACCESS PLUMBING LINE DESIGNATION SYMBOLS PC PUMPED CONDENSATE CWS CONDENSER WATER SUPPLY LL REFRIGERANT LIQUID LINE SL REFRIGERANT SUCTION LINE DOMESTIC COLD WATER (POTABLE) DOMESTIC HOT WATER (POTABLE) DOMESTIC HOT WATER CIRCULATING (POTABLE) SANITARY SEWER ABOVEGROUND VENT PIPING G LOW PRESSURE NATURAL GAS MPG MEDIUM PRESSURE NATURAL GAS A COMPRESSED AIR NPCW NON-POTABLE COLD WATER NPHW NON-POTABLE HOT WATER NPHWC NON-POTABLE HOT WATER CIRCULATING IRR IRRIGATION SANITARY SEWER UNDERGROUND GREASE WASTE ABOVEGROUND GREASE WASTE UNDERGROUND ACID RESISTANT (CHEMICAL) WASTE ABOVEGROUND ACID RESISTANT (CHEMICAL) WASTE UNDERGROUND ACID RESISTANT (CHEMICAL) VENT PIPING AW GW GW AW AV VAC VACUUM RWL RAIN WATER LEADER ORWL OVERFLOW RAIN WATER LEADER C CONDENSATE DRAIN HVAC LINE DESIGNATION SYMBOLS CLEAR INSIDE DUCT SIZE INTERNALLY LINED DUCTWORK MANUAL VOLUME DAMPER BACKDRAFT DAMPER MOTOR OPERATED DAMPER FIRE DAMPER SMOKE DAMPER COMBINATION FIRE/SMOKE DAMPER HORIZONTAL FIRE DAMPER HORIZONTAL SMOKE DAMPER HORIZONTAL COMBINATION FIRE/SMOKE DAMPER FLEXIBLE CONNECTION UC UNDERCUT DOOR SUPPLY AIR DUCT SECTION RETURN OR OUTSIDE AIR DUCT SECTION EXHAUST AIR DUCT SECTION RECTANGULAR DUCT UP RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN FLEXIBLE DUCTWORK VALVE CHECK VALVE BALANCING VALVE THREE WAY CONTROL VALVE TWO WAY CONTROL VALVE SOLENOID VALVE PRESSURE REDUCING VALVE (PRV) S TEMPERATURE/PRESSURE RELIEF VALVE RELIEF/SAFETY VALVE MANUAL AIR VALVE AAV AUTOMATIC AIR VENT (EXTEND DISCHARGE TO DRAIN) FLOW METER AUTOMATIC FLOW CONTROL VALVE DIRECTION OF FLOW STRAINER STRAINER WITH BLOW OFF VALVE UNION ANCHOR GUIDE PT/PS FS TT FLOW SWITCH TEMPERATURE TRANSMITTER PRESSURE GAUGE PRESSURE TRANSMITTER OR PRESSURE SWITCH THERMOMETER AQUASTAT GAUGE WITH GAUGE COCK & SIPHON (STEAM) GAS PRESSURE REGULATOR TEMPERATURE/PRESSURE TEST PORT BASKET STRAINER STEAM TRAP EXPANSION JOINT VACUUM BREAKERVB FLEXIBLE CONNECTORS SPRINKLER HEAD BACKFLOW PREVENTION DEVICE (REDUCED ZONE) BACKFLOW PREVENTION DEVICE (DOUBLE CHECK VALVE ASSEMBLY) WATER HAMMER ARRESTER HOSE BIBB ROOF DRAIN FLOOR DRAIN CLEANOUT (FLOOR)FCO CLEANOUTCO PIPE CONTINUES PIPE CAP VENT THRU ROOFVTR TRENCH DRAIN PIPE RISING UP PIPE DROPPING DOWN PIPE CONNECTION PIPE CONNECTION DOWN DIRECTION OF PITCH-RISE OR DROPRD BDD CONTROL SYMBOLS T S H CO2 VFD STR X XxXXø CFM CO DDC AIR DEVICE TAG SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE SIDEWALL GRILLE (SUPPLY), LOUVER (EXHAUST OR RETURN) SIDEWALL GRILLE (RETURN OR EXHAUST), LOUVER (OUTSIDE) LINEAR GRILLE ROUND DIFFUSER ROOM TEMPERATURE SENSOR "THERMOSTAT" ROOM SENSOR ROOM HUMIDITY SENSOR ROOM CARBON MONOXIDE SENSOR ROOM CARBON DIOXIDE SENSOR VARIABLE FREQUENCY DRIVE STARTER OR STARTER/DISCONNECT DIRECT DIGITAL CONTROL PANEL DIFFUSER, REGISTER, AND GRILLE SYMBOLS CONTROL WIRINGFDDRY FIRE SPRINKLER F FIRE SPRINKLER FIRE PROTECTION LINE DESIGNATION SYMBOLS DTR DUAL TEMPERATURE HEATING AND COOLING WATER RETURN DTS DUAL TEMPERATURE HEATING AND COOLING WATER SUPPLY MU MAKEUP WATER CLEANOUT (WALL)WCO DUCT SMOKE DETECTOR WATER METER PUMP WM DP DIFFERENTIAL PRESSURE TRANSMITTER $SWITCH P ROOM PRESSURE SENSOR OS OCCUPANCY SENSOR FM GAS METERGM FLOOR SINK MECHANICAL SHEET LIST M-001 MECHANICAL LEGEND M-002 MECHANICAL ABBREVIATIONS AND GENERAL NOTES M-003 MECHANICAL SCHEDULES M-004 MECHANICAL SCHEDULES M-005 MECHANICAL SCHEDULES M-006 MECHANICAL SCHEDULES M-007 MECHANICAL SCHEDULES M-101 MECHANICAL SITE PLAN M-121 FOUNDATION PLUMBING PLAN - ZONE A M-122 FOUNDATION PLUMBING PLAN - ZONE B M-123 FOUNDATION PLUMBING PLAN - ZONE C M-124 FOUNDATION PLUMBING PLAN - ZONE D M-221 FIRST FLOOR PLUMBING PLAN - ZONE A M-222 FIRST FLOOR PLUMBING PLAN - ZONE B M-223 FIRST FLOOR PLUMBING PLAN - ZONE C M-224 FIRST FLOOR PLUMBING PLAN - ZONE D M-231 MECHANICAL LEVEL PLUMBING PLAN M-311 FIRST FLOOR OVERALL HVAC FLOOR PLAN M-321 FIRST FLOOR HVAC PLAN - ZONE A M-322 FIRST FLOOR HVAC PLAN - ZONE B M-323 FIRST FLOOR HVAC PLAN - ZONE C M-324 FIRST FLOOR HVAC PLAN - ZONE D M-331 MECHANICAL LEVEL HVAC PLAN M-421 FIRST FLOOR HVAC PIPING PLAN - ZONE A M-422 FIRST FLOOR HVAC PIPING PLAN - ZONE B M-423 FIRST FLOOR HVAC PIPING PLAN - ZONE C M-424 FIRST FLOOR HVAC PIPING PLAN - ZONE D M-431 MECHANICAL LEVEL HVAC PIPING PLAN M-501 ENLARGED MECHANICAL PLAN - BOILER ROOM M-502 ENLARGED MECHANICAL PLAN - KITCHEN M-503 ENLARGED PLUMBING PLAN - ACTIVITIES RESTROOM M-504 MECHANICAL SECTIONS M-505 MECHANICAL SECTIONS M-601 MECHANICAL ROOF PLAN M-701 FIRST FLOOR FIRE SPRINKLER PLAN M-702 MECHANICAL LEVEL FIRE SPRINKLER PLAN M-801 HYDRONIC WATER PIPING RISER DIAGRAM M-802 GAS RISER DIAGRAM M-901 MECHANICAL DETAILS M-902 MECHANICAL DETAILS M-903 MECHANICAL DETAILS M-904 MECHANICAL DETAILS 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN 1/ 6 / 2 0 1 7 1 1 : 4 1 : 0 5 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 MECHANICAL LEGEND M-001 DNDN DNDN H1E1 D D T T T T T T T T T T TT T T T T T T TT T T T T T T T TT T T T T T T T T T T TT TT TT TT T T TT T T TTTT T TT T T TT T T T TCO2 TT T T LC (I) 407 LC (P) 603 LC (P) 301 LC (K) 203 LC (K) 208 LC (P) 403 LC (I) 305 LC (I) 607 LC (I) 505 LC (P) 501 MECH 504 MECH 606 MECH 206 KITCHEN 117 MECH 304 MECH 406 IDF 405A ELEC 405 ELEC 205 IDF 205A LIBRARY 131 CUSTODIAL / RECIEVING 126 BOILER/MECH 125 LC (DHH) 401 LC (DHH) 402 GYM 107 RISERS 107D MUSIC 122 ORCH 123 BAND 121 PRACTICE 124C PRACTICE 121B PRACTICE 121A MUSIC OFFICE / STOR 124D SERVERY 115A COMMONS 115 STAFF LOUNGE 101P PR O F . DE V E L O P M E N T 10 1 T WO R K RO O M 10 1 M P. O F F I C E 10 1 S A. P . O F F I C E 10 1 R DE A N O F ST U D E N T S 10 1 E COT ROOM 101D HE A L T H CL I N I C 10 1 B DH H R E C / IN T E R P R E T 10 1 Q RECEPTION OFFICE 101 HALLWAY GYM 100E HALLWAY GYM 100D DRY STOR 117B DH H O F F I C E 10 1 N DH H O F F I C E 10 1 L MECH STAIR S2 TLT 101DA OF F I C E MG R 10 1 C SCI PREP 136A IDF 303A ELEC 303 LC C I R C / ST O R A G E 30 1 A IDF 503A ELEC 503 TLT 101H TLT 101J LOBBY 100A HALLWAY ADMIN 101U HALLWAY LIBRARY 140 F. RISER 125A DEN 104 LEARNING SUPPORT 102 LC (DHH) 134 SM GROUP 134A TLT 104A TLT 106 COUNSELOR 103 HALLWAY DEN 100B CO N F E R E N C E 10 1 A IDF 101F CUST 101MA HA L L W A Y CO M M O N S 10 0 C HALLWAY MUSIC 120 LC CIRC 401C LC CIRC 601C LC CIRC 201C LC (M) 201 LC (M) 602 SECURITY ENTRANCE 100 LC C I R C / ST O R A G E 50 1 A OFFICE/ WORKROOM ELEC 128 SM GROUP 201A SM GROUP 201B LC (M) 202 SM GROUP 401B SM GROUP 401A SM GROUP 601B SM GROUP 601A LC (M) 601 SM GROUPSM GROUP SM GROUP SM GROUP SM GROUP SM GROUPSM GROUP SM GROUP SM GROUP SM GROUP SM GROUPSM GROUP SM GROUP SM GROUP SM GROUPSM GROUP LC (K) 207 LC (DHH PK/K) 204 IDF 605A ELEC 605LC C I R C / ST O R A G E 60 3 A SLP 108 OTPT 111 AUDIO / DHH SLP 110 DHH PSYCH / COUNS 109 ELEC 133A SM GROUP 207B SM GROUP 207A SM GROUP 203B SM GROUP 203A PE STORAGE 107B VESTIBULE COMMONS 100F LEARNING SUPPORT 102B BOOK STORAGE 131B MDF 133B ELEC 101G RE C O R D ST O R A G E 10 1 K TLT 105 GREEN ROOM 131C MECH 129 PA R E N T RO O M 13 2 LC CIRC / STORAGE 203D LC C I R C / ST O R A G E 40 3 A LC CIRC 205 K TLT 203C MIT OFFICE 132B TLT 132A LEARNING SUPPORT 102A KILN COMMONS STORAGE 127 GYM OFFICE 113 TLT 113A COMMUNITY STOR 114 TLT 135 LC (M SCI) 136 INST STOR 124 HALLWAY MUSIC 134LL AHU-03 1 1.1 2 2.3 4 6 83 5 7 119 1413 10 12 A D E F H L K G F.8 C.2 J B C A.3 D.5 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN B C1 C2 D1 D2 D3 A 1/ 6 / 2 0 1 7 1 1 : 4 1 : 3 3 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 FIRST FLOOR OVERALL HVAC FLOOR PLAN M-311 DNDN CO2 T T T T T T T T T T T T T T T T T T T T T T T T T T T CO2 T GYM 107 RISERS 107D MUSIC 122 STAFF LOUNGE 101P PR O F . DE V E L O P M E N T 10 1 T WO R K RO O M 10 1 M P. O F F I C E 10 1 S A. P . O F F I C E 10 1 R DE A N O F ST U D E N T S 10 1 E COT ROOM 101D HE A L T H CL I N I C 10 1 B DH H R E C / IN T E R P R E T 10 1 Q RECEPTION OFFICE 101 HALLWAY GYM 100E HALLWAY GYM 100D DH H O F F I C E 10 1 N DH H O F F I C E 10 1 L TLT 101DA OF F I C E MG R 10 1 C TLT 101H TLT 101J LOBBY 100A HALLWAY ADMIN 101U DEN 104 LEARNING SUPPORT 102 TLT 104A TLT 106 COUNSELOR 103 HALLWAY DEN 100B CO N F E R E N C E 10 1 A IDF 101F CUST 101MA HA L L W A Y CO M M O N S 10 0 C SECURITY ENTRANCE 100 SLP 108 OTPT 111 AUDIO / DHH SLP 110 DHH PSYCH / COUNS 109 PE STORAGE 107B VESTIBULE COMMONS 100F LEARNING SUPPORT 102B ELEC 101G RE C O R D ST O R A G E 10 1 K TLT 105 LEARNING SUPPORT 102A HALLWAY MUSIC 134LL L 8150 3 M-504 H 48"x60" 5800 (12" A.F.F.) UH-13 UH-15 1 1.1 2 2.3 3 K G F.8 D.5 SAC-07 SEE SHEET M-331 FOR MECH LEVEL PLAN 60"x20" 26"x14" 56 " x 2 4 " /1 M-322 UH-12 UH-14 VAV-165 VAV-164 VAV-147 VAV-146 VAV-163 VAV-162 H 48"x60" 5800 (18" A.F.F.) 24"x48" SEE SHEET M-331 FOR MECH LEVEL PLAN 1 M-505 VAV-167 12"x10" A 8"ø 210 (TYP 2) VAV-166 E 12"x12" 150 E 12"x12" 150 E 12"x12" 150 32"x16" 22 " x 1 4 " 14 " x 1 0 " 22"x14" 12"x8" 14"x14" VAV-152VAV-160 VAV-159 $1 2 36"x42" (TYP 4) A 12"ø 360 E 24"x12" 360 10"x10" A 12"ø 365 (TYP 2) E 24"x24" 730 16"x12" 14"x14" 20"x12"20"x20" 14"x14" A 12"ø 325 (TYP 2) 18 " x 1 4 " E 24"x24" 650 A 12"ø 355 E 24"x12" 355 E 24"x12" 320 A 10"ø 320 14"x14"E 24"x12" 235 A 10"ø 235 VAV-158 14"x12" (TYP 2) (TYP 2) 20"x18"30"x20" E 24"x12" 350 A 12"ø 350 (TYP 2) (TYP 2) VAV-157 14"x14" E 24"x12" 310 A 10"ø 310 VAV-156 12"x10" E 24"x12" 200 A 10"ø 310 (TYP 2) 22"x12" 42"x20" 10"x10" 12"x12" E 24"x12" 300 12"x12" 8"x8" A 10"ø 300 VAV-161 42"x20" E 24"x12" 200 8"x8" 20"x14" EXH UP TO EF-11R18"x12" 200 16"x12" 16"x12" E 12"x12" 150 E 12"x12" 150 10"x10" E 24"x12" 300 10"x10" A 10"ø 300 VAV-155 12"x10" E 24"x12" 200 8"x8" E 12"x12" 150 E 24"x12" 200 A 10"ø 300 VAV-154 12"x10" E 24"x12" 300 10"x10" 10"x18" UP U 32"ø 5700T32"ø 5700 E 24"x12" 360 18 " x 1 0 " A 12"ø 360 14"x14" VAV-153 K 10"ø 225 (TYP 2) (TYP 4) 8"x8" 10"x10" EXH UP TO EF-12 10"x10" E 24"x12" 330 A 12"ø 330 A 12"ø 350 (TYP 4) VAV-151 VAV-150 A 8"ø 165 E 24"x12" 165 VAV-148 VAV-149 A 12"ø 315 E 24"x24" 1260 E 24"x24" 700 (TYP 2) 16"x12" (TYP 2) A 8"ø 155 E 24"x12" 410 8"x8" 12"x12" 16"x12"22"x14" 30"x16" 12"x10" A 8"ø 150 K 10"ø 190 (TYP 12) 26"x14" E 24"x24" 950 E 24"x12" 150 8"x8" 12"x8" A 8"ø 145 E 24"x12" 145 8"x8" 8"x8" A 8"ø 135 12"x8" E 24"x12" 135 E 24"x12" 410 56"x24" 48"x18" E 24"x24" 590 12"x12" UP 32"ø 32"ø 3 3 SHEET NOTES 1. COORDINATE CLEAR AND MAINTAINABLE ACCESS TO ALL ABOVE CEILING EQUIPMENT. DASHED LINES REPRESENT MIN CLEAR AREA REQUIRED. 2. PROVIDE ACCESS DOORS IN DUCTWORK FOR ACCESS TO BACKDRAFT DAMPERS AND MOTORIZED DAMPERS AS REQUIRED. 3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF DIFFUSERS AND GRILLES. WHERE NOT SHOWN, COMPLY WITH THESE PLANS. 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF SIDEWALL GRILLES, THERMOSTATS AND CO2 SENSORS. 5. LOCATE VAV BOXES AT ELEVATIONS ACCESSIBLE VIA A- FRAME LADDER BELOW CEILING. 6. GENERAL EXHAUST OF SPACES 100 CFM OR LESS IS MADE UP VIA TRANSFER UNDER DOOR TO ADJACENT SPACE. COORDINATE MIN 1/2" UNDERCUT WITH GC. 7. PRIMARY AIR DUCT SIZE TO EACH SINGLE-DUCT AIR TERMINAL UNIT SHALL BE PER VAV SCHEDULES. PROVIDE TRANSITION AT TERMINAL UNIT INLET AS REQUIRED. 8. PLENUMS LOCATED BEHIND LOUVERS SHALL BE SIZED TO MATCH LOUVER SIZE UNLESS OTHERWISE NOTED. 9. PROVIDE ACCESS DOOR IN AIR PLENUM OR DUCTWORK LOCATED BEHIND LOUVERS FOR MOTORIZED DAMPER ACCESS. PROVIDE 24x24 ACCESS DOOR UNLESS OTHERWISE NOTED. 10. SEAL MECHANICAL LEVEL FLOOR PENETRATIONS WATER TIGHT. 11. MAINTAIN MINIMUM 6'-8"x3'-0" CLEAR PATHWAY THROUGH MECHANICAL ROOMS. FLAG NOTES 1 230900 SHALL PROVIDE EMERGENCY VENTILATION SHUTOFF SWITCH. 4"DIA EXHAUST DOWN TO DRYER CONNECTION. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ROUTE UP TO PRE-FABRICATED SHEET METAL ROOF CAP (DRYERJACK WITH 4" COLLAR AND CURB OR APPROVED EQUAL). COORDINATE TERMINATION UP TO ROOF WITH ARCHITECT. TRANSITION SHEET METAL TO FLEXIBLE DIFFUSION OUTLET SYSTEM. PROVIDE HANGERS PER MANUFACTURER'S RECOMMENDATIONS. 2 3 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN B C1 C2 D1 D2 D3 A 1/ 6 / 2 0 1 7 1 1 : 4 1 : 4 4 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 FIRST FLOOR HVAC PLAN - ZONE A M-321SCALE: 1/8" = 1'-0"M-321 1 FIRST FLOOR HVAC PLAN - ZONE A S-WF1 S-WF1 Tectonic Copyright 2007 T T T T T T T TT H1E1 D D T T CO2 T T TT T T T T T T CO2 T T CO2 CO2 CO2 T T T T T T KITCHEN 117 LIBRARY 131 CUSTODIAL / RECIEVING 126 BOILER/MECH 125 MUSIC 122 ORCH 123 BAND 121 PRACTICE 121C PRACTICE 121B PRACTICE 121A MUSIC OFFICE / STOR 121D SERVERY 115A COMMONS 115 DRY STOR 117B MECH STAIR S2 SCI PREP 136A HALLWAY LIBRARY 140B F. RISER 125A LC (DHH) 134 HALLWAY MUSIC 120 OFFICE/ WORKROOM ELEC 128 PE STORAGE 107A VESTIBULE COMMONS 100F BOOK STORAGE 131B MDF 137GREEN ROOM 135 MECH 129 PA R E N T RO O M 13 2 MIT OFFICE 132B TLT 132A KILN COMMONS STORAGE 127 GYM OFFICE 113 TLT 113A COMMUNITY STOR 114 TLT 133 LC (M SCI) 136 RAMP 112A TLT 116B TLT 118B TLT 118A MUSIC STOR 122A GYM VESTIBULE 112 HALLWAY CUST 130 RISERS WALK-IN FREEZER 117A SM GROUP 131A HALLWAY VESTIBULE 140A SM GROUP 134A 2 M-505 L 8350 3 M-504 L 1000 EF-07 L 500 EF-03 UH-02 E 24"x24" 1500 H 48"x60" 5800 (12" A.F.F.) H 24"x36" 1500 UH-06 HRU-01 1 1.1 2 2.3 43 A D C.2 B C A.3 D.5 16x16 UP TO EF-01 ON ROOF SEE SHEET M-331 FOR MECH LEVEL PLAN 40"x30" 26"x14" 22"x14" 22"x14" 22 " x 1 4 " 22 " x 1 4 " 22 " x 1 4 " 22 " x 1 4 " 40"x16" SEE SHEET M-501 FOR ENLARGED BOILER ROOM PLAN SAC-01 H 24"x36" 1500 / 1 M-323 /1 M-321 3 M-506 E 12"x12" 150 VAV-105 VAV-104 E 24"x24" 1000 E 24"x24" 305 1 M-506 UH-03 UH-04 VAV-102 UH-12 E 24"x24" 750 (TYP 2) 36"x30" C 10"ø 175 C 10"ø 225 (TYP 6) (TYP 2) A 8"ø 200 E 24"x12" 200 A 8"ø 150 UH-05 48"x42" UP TO ROOF HOOD RFH-09 48"x42" UP TO ROOF HOOD RFH-10 UP TO ROOF HOOD RFH-11 L 1000 EF-10 $ 1 2 3 3 48"x54" UP TO ROOF HOOD RFH-12 E 24"x24" 1200 EXH UP TO EF-05 EXH UP TO EF-06 24"x12" L 150 WALL CAP 70"x16"50"x16" 60"x16" 54"x16" 12"x12" 16"x16" E 12"x12" 150 20"x14" A 10"ø 200 A 10"ø 200 42"x20"24"x14" 26 " x 2 0 " C 10"ø 210 E 24"x12" 130 8"x8" B 23"x23" 130 12"x4" 12"x10" B 36"x48" 505 20"x14" E 24"x12" 100 B 23"x23" 100 12"x8" 4"x12" 16 " x 1 2 " 12"x12" 2 M-506 E 24"x24" 1200 8"x8" E 24"x12" 140 30 " x 1 6 " E 24"x24" 1085 20"x14" 20"x14" 24"x12" E 24"x12" 115 8"x8" B 80"x52" 1085 12"x12" (TYP 7) 14"x12" 14 " x 1 2 " C 12"ø 360 H 36"x48" 1800 26"x14"E 24"x24" 900 (TYP 5) 36"x30" UP TO ROOF HOOD RFH-02 UP TO ROOF HOOD RFH-04 E 24"x12" (TYP 2) E 24"x12" 150 E 24"x24" 750 (TYP 2) 36"x30" UP TO ROOF HOOD RFH-03 E 24"x12" (TYP 4) A 8"ø 100 E 24"x12" 100 C 10"ø 225 (TYP 2) C 10"ø 175(TYP 6) A 12"ø 500 6"ø R 18"x12" 500 EXH UP 24"x12" (TYP 22) 22"x14" 22"x14" 32"ø 32"ø A 10"ø 200 E 24"x12" 200 (TYP 2) 50"x20" 48"x54" A 10"ø 300 (TYP 5) 16 " x 1 2 " 18"x12" 10"x10" 10"x10" L 1000 30"x24" 12"x12" UP TO EF- 08 12"x12" 5 (TYP 2) (TYP 2) 5 DS-01 DS-02 5 5 5 11 6 7 8 9 10 10 10 10 10 DS-10 DS-11 12 E 48"x24" 1925 30"x24"(TYP 4) (TYP 4) 20 " x 1 2 " 20 " x 1 2 " 16"x16" 14"x12" 16 " x 1 2 " 8"x8" A 8"ø 200 (TYP 2) E 24"x12" 200(TYP 2) 12"x12" 12"x12" 10"x10" 10"x10" (TYP 2) (TYP 2) 24"x12" 1 (TYP 2) (TYP 2) E 24"x12" (TYP 2) 12"x12" E 24"x12" 200 A 10"ø 200 B 23"x23" 140 12"x4" (TYP 2) E 24"x24" 20"x12" VAV-108 VAV-107 E 24"x12" 200 8"x8" 34"x16" 8"x8" 12"x4" B 23"x23" 120 (TYP 2) (TYP 2) 12"x10" E 24"x12" 240 B 80"x24" 400 16"x12" E 24"x24" 20"x12" 20"x18" 20"x12" B 56"x52" 800 18"x14" R 12"x12" 200 16"x12" R 24"x12" 12"ø B 72"x52" 950 14x14 UP TO EF-02 ON ROOF K 10"ø 185K10"ø 185K10"ø 180 E 12"x12" 150 (TYP 2) 8"x8" (TYP 18)12"x12" E 12"x12" 75 (TYP 14) E 12"x12" 100 E 12"x12" 100 (TYP 2) 4"ø 13 VAV-106 FCU-03 14 E 12"x12" 150 8"x8" 12"x8" (TYP 3) 15 4 12"x8" 8"x8" 12"x8" 12"x12" (TYP 2) 12"x12" (TYP 3) 8"x8" 12"x12"(TYP 2) 30"x24" 20"x14" (TYP 2) 12"x12" VAV-101 VAV-103 B 23"x23" 115 VAV-109 16 16 R 24"x12" R 24"x12" 17 17 $18 17 $18 24 " x 1 2 " 16 16 16 SHEET NOTES 1. COORDINATE CLEAR AND MAINTAINABLE ACCESS TO ALL ABOVE CEILING EQUIPMENT. DASHED LINES REPRESENT MIN CLEAR AREA REQUIRED. 2. PROVIDE ACCESS DOORS IN DUCTWORK FOR ACCESS TO BACKDRAFT DAMPERS AND MOTORIZED DAMPERS AS REQUIRED. 3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF DIFFUSERS AND GRILLES. WHERE NOT SHOWN, COMPLY WITH THESE PLANS. 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF SIDEWALL GRILLES, THERMOSTATS AND CO2 SENSORS. 5. LOCATE VAV BOXES AT ELEVATIONS ACCESSIBLE VIA A- FRAME LADDER BELOW CEILING. 6. GENERAL EXHAUST OF SPACES 100 CFM OR LESS IS MADE UP VIA TRANSFER UNDER DOOR TO ADJACENT SPACE. COORDINATE MIN 1/2" UNDERCUT WITH GC. 7. PRIMARY AIR DUCT SIZE TO EACH SINGLE-DUCT AIR TERMINAL UNIT SHALL BE PER VAV SCHEDULES. PROVIDE TRANSITION AT TERMINAL UNIT INLET AS REQUIRED. 8. PLENUMS LOCATED BEHIND LOUVERS SHALL BE SIZED TO MATCH LOUVER SIZE UNLESS OTHERWISE NOTED. 9. PROVIDE ACCESS DOOR IN AIR PLENUM OR DUCTWORK LOCATED BEHIND LOUVERS FOR MOTORIZED DAMPER ACCESS. PROVIDE 24x24 ACCESS DOOR UNLESS OTHERWISE NOTED. 10. SEAL MECHANICAL LEVEL FLOOR PENETRATIONS WATER TIGHT. 11. MAINTAIN MINIMUM 6'-8"x3'-0" CLEAR PATHWAY THROUGH MECHANICAL ROOMS. FLAG NOTES 1 MOTORIZED DAMPER TO CLOSE DURING MORNING WARM-UP. 230900 SHALL PROVIDE ZONE FLUSH OUT MUSHROOM TYPE PURGE SWITCH. LOCATE PER ARCHITECT. PROVIDE CONNECTIONS TO TYPE II KITCHEN HOOD AND DISHWASHER EXHAUST SUPPLIED BY OTHERS. SEE FOOD SERVICE DRAWINGS FOR ADDITIONAL INFORMATION. SS WELDED DISHWASHER EXHAUST DUCT SLOPED MIN 2% TOWARD HOOD. WRAP ALL DUCT OVER STAGE PLATFORM WITH 2 LB/SF DUCT LAGGING MATERIAL, SOUND SEAL B-20/QFA-3 OR EQUAL. CONSTRUCT DUCT OF MIN 20 GAUGE SHEET METAL FROM THE UNIT DOWNSTREAM FOR A MINIMUM OF 15 FT. CONSTRUCT DUCT OF MIN 20 GAUGE SHEET METAL FROM THE UNIT DOWNSTREAM TO DUCT SILENCER. CONSTRUCT DUCT OF MIN 20 GAUGE SHEET METAL FOR ALL DUCT ABOVE CORRIDOR. CONSTRUCT DUCT OF MIN 24 GAUGE SHEET METAL FOR ALL EXPOSED DUCT ABOVE COMMONS. CONSTRUCT DUCT OF MIN 20 GAUGE SHEET METAL FOR ALL DUCT MAINS IN COMMONS. WRAP DUCT FOR A MINIMUM OF 10FT WITHIN THE COMMONS WITH 2 LB/SF DUCT LAGGING MATERIAL, SOUND SEAL B- 20/QFA-3 OR EQUAL. CONSTRUCT ALL DUCT RUNNING OVER LC (DHH) OF MIN. 22 GUAGE SHEET METAL. 4"DIA EXHAUST DOWN TO DRYER CONNECTION. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE FINAL LOCATIONS OF SLOT DIFFUSERS LOCATED WITHIN WOOD SLAT CEILING WITH ARCHITECT PRIOR TO INSTALL. DIFFUSERS TO BE COORDINATED WITH LIGHTING FIXTURES & SPEAKERS AS NECESSARY. PROVIDE (2) 4"Ø SS WELDED DUCT TO FLAMMABLES CABINET PER MANUFACTURER REQUIREMENTS. TERMINATE AT ROOF. PROVIDE SCREENED OPENING. PROVIDE STAINLESS STEEL MOTORIZED DAMPER. 230900 SHALL PROVIDE SWITCH FOR FAN OPERATION. LOCATE PER ARCHITECT. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN B C1 C2 D1 D2 D3 A 3/ 2 8 / 2 0 1 7 1 0 : 0 1 : 4 4 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 FIRST FLOOR HVAC PLAN - ZONE B M-322 SCALE: 1/8" = 1'-0"M-322 1 FIRST FLOOR HVAC PLAN - ZONE B 03/28/2017 PERMIT REV 01 1 1 T T TT T T T T T T T T T T LC (P) 301 LC (I) 305 LC (I) 505 LC (P) 501 MECH 504MECH 304 IDF 303A ELEC 303 LC C I R C / ST O R A G E 30 1 A IDF 503A ELEC 503 LC C I R C / ST O R A G E 50 1 A SM GROUP SM GROUP SM GROUPSM GROUP SM GROUP SM GROUP SM GROUPSM GROUP 6 8 10 12 A D B C / 1 M-322 /1 M-324 SAC-02A SAC-02B SAC-03A SAC-03B L 106"x30" 4420 UH-08 40"x30" HRU-03 70"x16" H 80"x40" 4420H80"x40" 4420 70"x16" HRU-02 40"x30" UH-07 L 106"x30" 4420 30"x12" R 30"x12" 1105 VAV-117 B 48"x48" 735 30"x12" 36"x12" 26"x12" B 96"x12" 370 R 30"x12" 1105 30"x12" 24"x16" VAV-116 B 48"x48" 735 30"x12" 36"x12" 26"x12" 30"x14" 50"x20" E 24"x12" (TYP 2) 12"x12" E 12"x12" 150 E 12"x12" 100 E 12"x12" 150 10"x10" 8"x8" 26"x12" 36"x12"B 96"x12" 370B96"x12" 370 30"x12" B 48"x48" 735 VAV-115 26 " x 1 4 " 26 " x 1 4 " 24"x16"24"x16" R 30"x12" 1105 30"x12" 36"x12" 30"x12" B 48"x48" 735 VAV-114 B 96"x12" 370 R 30"x12" 1105 30"x12"30"x12" 1 1 12"x12" EXH UP TO EF-14 26"x12"26"x12" 36"x12" 30"x12" B 48"x48" 735 VAV-111 R 30"x12" 1105 30"x12" R 30"x12" 1105 VAV-110 50"x20" 30"x14" 26"x12" 36"x12" 30"x12" B 48"x48" 735 VAV-113 30"x12" R 30"x12" 1105 30"x12" R 30"x12" 1105 VAV-112 B 48"x48" 735 30"x12" 36"x12" 26"x12" E 12"x12" 150 E 12"x12" 100 E 12"x12" 150 26"x12" 36"x12" 12"x12" EXH UP TO EF-13 30"x12" SHEET NOTES 1. COORDINATE CLEAR AND MAINTAINABLE ACCESS TO ALL ABOVE CEILING EQUIPMENT. DASHED LINES REPRESENT MIN CLEAR AREA REQUIRED. 2. PROVIDE ACCESS DOORS IN DUCTWORK FOR ACCESS TO BACKDRAFT DAMPERS AND MOTORIZED DAMPERS AS REQUIRED. 3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF DIFFUSERS AND GRILLES. WHERE NOT SHOWN, COMPLY WITH THESE PLANS. 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF SIDEWALL GRILLES, THERMOSTATS AND CO2 SENSORS. 5. LOCATE VAV BOXES AT ELEVATIONS ACCESSIBLE VIA A- FRAME LADDER BELOW CEILING. 6. GENERAL EXHAUST OF SPACES 100 CFM OR LESS IS MADE UP VIA TRANSFER UNDER DOOR TO ADJACENT SPACE. COORDINATE MIN 1/2" UNDERCUT WITH GC. 7. PRIMARY AIR DUCT SIZE TO EACH SINGLE-DUCT AIR TERMINAL UNIT SHALL BE PER VAV SCHEDULES. PROVIDE TRANSITION AT TERMINAL UNIT INLET AS REQUIRED. 8. PLENUMS LOCATED BEHIND LOUVERS SHALL BE SIZED TO MATCH LOUVER SIZE UNLESS OTHERWISE NOTED. 9. PROVIDE ACCESS DOOR IN AIR PLENUM OR DUCTWORK LOCATED BEHIND LOUVERS FOR MOTORIZED DAMPER ACCESS. PROVIDE 24x24 ACCESS DOOR UNLESS OTHERWISE NOTED. 10. SEAL MECHANICAL LEVEL FLOOR PENETRATIONS WATER TIGHT. 11. MAINTAIN MINIMUM 6'-8"x3'-0" CLEAR PATHWAY THROUGH MECHANICAL ROOMS. FLAG NOTES 1 MOTORIZED DAMPER TO CLOSE DURING MORNING WARM- UP. 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN B C1 C2 D1 D2 D3 A 1/ 6 / 2 0 1 7 1 1 : 4 1 : 5 9 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 FIRST FLOOR HVAC PLAN - ZONE C M-323SCALE: 1/8" = 1'-0"M-323 1 FIRST FLOOR HVAC PLAN - ZONE C T T T T T T T TT T T TT T T T T T TT T TT T T TTTT T TT T T T T LC (I) 407 LC (P) 603 LC (K) 203 LC (K) 208 LC (P) 403 LC (I) 607 MECH 606 MECH 206 MECH 406 IDF 405A ELEC 405 ELEC 205 IDF 205A LC (DHH) 401 LC (DHH) 402 LC CIRC 401C LC CIRC 601C LC CIRC 201C LC (M) 201 LC (M) 602 SM GROUP 201A SM GROUP 201B LC (M) 202 SM GROUP 401B SM GROUP 401A SM GROUP 601B SM GROUP 601A LC (M) 601 SM GROUPSM GROUP SM GROUP SM GROUP SM GROUP SM GROUPSM GROUP SM GROUP LC (K) 207 LC (DHH PK/K) 204 IDF 605A ELEC 605 LC C I R C / ST O R A G E 60 3 A SM GROUP 207B SM GROUP 207A SM GROUP 203B SM GROUP 203A LC CIRC / STORAGE 203D LC C I R C / ST O R A G E 40 3 A LC CIRC 205 K TLT 203C 1 M-504 2 M-504 B 96"x12" 370 VAV-140 VAV-141 SAC-06A UH-11 H 80"x40" 6640 6 8 5 7 119 1413 10 12 E F H L J 40 " x 1 6 " E 24"x12" 105 E 24"x12" 105 SAC-04A / 1 M-321 /1 M-323 B 96"x12" 370 B 48"x48" 735 B 48"x48" 735 26"x14" 30"x12" 26"x12" 36"x12" VAV-145 VAV-144 30"x12" 36"x12" 26"x12" 8"x8" 10"x10" L 106"x30" 6640 40"x30" 30"x14" R 30"x12" 1105 30"x12" 26 " x 1 4 " R 30"x12" 1105 30"x12" E 24"x12" 12"x12" (TYP 2) E 24"x12" 30"x20" 26 " x 1 4 " VAV-142 VAV-143 SAC-06B HRU-06 70"x16"E 12"x12" 150 8"x8" E 12"x12" 100 E 12"x12" 150 50"x20" 24 " x 1 6 " 24 " x 1 6 " VAV-138 36"x12" R 18"x12" VAV-139 R 30"x12" 1105 R 30"x12" 1105 R 30"x12" 1005 R 30"x12" 100510"x10" E 12"x12" 150 E 12"x12" 100 8"x8" F 24"x6" 105F24"x6" 105 SAC-04B SAC-05A SAC-05B H 80"x40" 6640 70"x16" HRU-05 40"x30" UH-10 L 106"x30" 6640 UH-09 HRU-04 L 106"x30" 6050 H 80"x40" 6050 VAV-132 VAV-133 VAV-126 VAV-128VAV-129 VAV-122 VAV-123 VAV-124 VAV-119 VAV-118 VAV-125 VAV-120 VAV-121 12"x12" EXH UP TO EF-16 12"x12" EXH UP TO EF-17 30"x12" 26"x14" R 30"x12" 1105 50"x20" 30"x14" 26"x12" 36"x12" 30"x12" B 48"x48" 735 VAV-137 B 96"x12" 370 R 30"x12" 1105 30"x12" VAV-136 B 48"x48" 735 30"x12" 26"x12" 36"x12" E 12"x12" 150 E 12"x12" 100 E 12"x12" 150 40 " x 1 6 " VAV-135 B 96"x12" 370 30"x20" 26 " x 1 4 " 26"x12" 36"x12" 30"x12" 26"x12" 36"x12" 30"x12" 30"x12" 2 2 2 2 30"x12" B 288"x12" 1005 B 288"x12" 1005 30"x12" 30"x12" 10"x10" 12"x8" 12"x8" R 30"x12" 1105 30"x12" 24 " x 1 6 " B 288"x12" 1005 36"x12" VAV-131 R 18"x12" E 24"x12" R 30"x12" 1005 10"x10" 30"x12" B 288"x12" 1005 E 12"x12" 150 E 12"x12" 100 VAV-130 R 30"x12" 1005 30"x12" 10"x10" F 24"x6" 105E24"x12" 105 F 24"x6" 105 E 24"x12" 105 12"x8" 12"x8" 30"x12" R 30"x12" 1105 VAV-134 12"x12" E 24"x12" (TYP 2) 10"x10" 8"x8" VAV-127 26 " x 1 4 " E 24"x24" 1000 B 192"x12" 1000 30"x14" 50"x20" 36"x12" 26"x14" F 24"x6" 105 F 24"x6" 105 E 24"x12" 105 E 24"x12" 105 12"x8" 12"x8" 10"x10" E 12"x12" 150 E 12"x12" 100 E 12"x12" 150 12"x12" E 24"x12" (TYP 2) 10"x10" 8"x8" 30"x20" 26 " x 1 4 " VAV-126 E 24"x24" 1000 36"x12" B 192"x12" 1000 B 192"x12" 1000B192"x12" 1000 36"x12"36"x12"1 E 12"x12" 150 40"x16" 24 " x 1 6 " 24 " x 1 6 " B 288"x12" 1005 E 12"x12" 150 E 12"x12" 100 1 1 1 1 R 30"x12" 1000 30"x12" R 30"x12" 1000 30"x12" E 24"x12" 105 F 24"x6" 105 F 24"x6" 105 E 24"x12" 105 R 18"x12" 1105 E 24"x12" 500 R 30"x12" 1005 30"x12" R 30"x12" 1005 30"x12" E 24"x12" 105 F 24"x6" 105 E 24"x12" 105 F 24"x6" 105 10"x10" 12"x12" EXH UP TO EF-15 26"x12" B 96"x12" 370 36"x12" 30"x12" B 48"x48" 735 B 48"x48" 735 26"x12"B 96"x12" 370 B 96"x12" 370 36"x12" 30"x12" B 48"x48" 735 B 48"x48" 735 2 222 2 2 2 2 2 2 2 2 1 SHEET NOTES 1. COORDINATE CLEAR AND MAINTAINABLE ACCESS TO ALL ABOVE CEILING EQUIPMENT. DASHED LINES REPRESENT MIN CLEAR AREA REQUIRED. 2. PROVIDE ACCESS DOORS IN DUCTWORK FOR ACCESS TO BACKDRAFT DAMPERS AND MOTORIZED DAMPERS AS REQUIRED. 3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF DIFFUSERS AND GRILLES. WHERE NOT SHOWN, COMPLY WITH THESE PLANS. 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF SIDEWALL GRILLES, THERMOSTATS AND CO2 SENSORS. 5. LOCATE VAV BOXES AT ELEVATIONS ACCESSIBLE VIA A- FRAME LADDER BELOW CEILING. 6. GENERAL EXHAUST OF SPACES 100 CFM OR LESS IS MADE UP VIA TRANSFER UNDER DOOR TO ADJACENT SPACE. COORDINATE MIN 1/2" UNDERCUT WITH GC. 7. PRIMARY AIR DUCT SIZE TO EACH SINGLE-DUCT AIR TERMINAL UNIT SHALL BE PER VAV SCHEDULES. PROVIDE TRANSITION AT TERMINAL UNIT INLET AS REQUIRED. 8. PLENUMS LOCATED BEHIND LOUVERS SHALL BE SIZED TO MATCH LOUVER SIZE UNLESS OTHERWISE NOTED. 9. PROVIDE ACCESS DOOR IN AIR PLENUM OR DUCTWORK LOCATED BEHIND LOUVERS FOR MOTORIZED DAMPER ACCESS. PROVIDE 24x24 ACCESS DOOR UNLESS OTHERWISE NOTED. 10. SEAL MECHANICAL LEVEL FLOOR PENETRATIONS WATER TIGHT. 11. MAINTAIN MINIMUM 6'-8"x3'-0" CLEAR PATHWAY THROUGH MECHANICAL ROOMS. FLAG NOTES 1 MOTORIZED DAMPER TO CLOSE DURING MORNING WARM- UP. LOCATE RETURN AIR GRILLE FLUSH WITHIN SKYLIGHT WELL. COORDINATE WITH ARCHITECT FOR FINAL LOCATION. 2 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN B C1 C2 D1 D2 D3 A 1/ 6 / 2 0 1 7 1 1 : 4 2 : 0 6 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 FIRST FLOOR HVAC PLAN - ZONE D M-324 SCALE: 1/8" = 1'-0"M-324 1 FIRST FLOOR HVAC PLAN - ZONE D DN OPEN TO GYM BELOW 3 M-504 30 " x 2 0 " 36 " x 1 4 " 14"x12"14"x22" 22"x14" 26"x14" 12"x12" 8"x8" 66"x24" H 48"x60" 5800 AHU-07 AHU-05 AHU-06 AHU-08 AHU-01 16"x12" 14"x12" FCU-01 22"x14" AHU-02 22"x14" 22"x14"FCU-02 22"x14" AHU-03 22"x14" 60"x20" 2 G C.2 AHU-04 EF-04 8"x8" 8"x8" 46 " x 2 4 " L 126"x48" 11010 L 90"x60" 11010 66"x24" 30"x56" L 154"x60" 19100 16"x16" UP TO ROOF HOOD RFH-01 56"x34" 32"ø (TYP 2) 56"x34" 48"x48" 90"x60" 126"x48" 16"x12" 16"x12" 22"x14" UP TO ROOF HOOD RFH-01 CC-01 SHEET NOTES 1. COORDINATE CLEAR AND MAINTAINABLE ACCESS TO ALL ABOVE CEILING EQUIPMENT. DASHED LINES REPRESENT MIN CLEAR AREA REQUIRED. 2. PROVIDE ACCESS DOORS IN DUCTWORK FOR ACCESS TO BACKDRAFT DAMPERS AND MOTORIZED DAMPERS AS REQUIRED. 3. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF DIFFUSERS AND GRILLES. WHERE NOT SHOWN, COMPLY WITH THESE PLANS. 4. SEE ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATIONS OF SIDEWALL GRILLES, THERMOSTATS AND CO2 SENSORS. 5. LOCATE VAV BOXES AT ELEVATIONS ACCESSIBLE VIA A- FRAME LADDER BELOW CEILING. 6. GENERAL EXHAUST OF SPACES 100 CFM OR LESS IS MADE UP VIA TRANSFER UNDER DOOR TO ADJACENT SPACE. COORDINATE MIN 1/2" UNDERCUT WITH GC. 7. PRIMARY AIR DUCT SIZE TO EACH SINGLE-DUCT AIR TERMINAL UNIT SHALL BE PER VAV SCHEDULES. PROVIDE TRANSITION AT TERMINAL UNIT INLET AS REQUIRED. 8. PLENUMS LOCATED BEHIND LOUVERS SHALL BE SIZED TO MATCH LOUVER SIZE UNLESS OTHERWISE NOTED. 9. PROVIDE ACCESS DOOR IN AIR PLENUM OR DUCTWORK LOCATED BEHIND LOUVERS FOR MOTORIZED DAMPER ACCESS. PROVIDE 24x24 ACCESS DOOR UNLESS OTHERWISE NOTED. 10. SEAL MECHANICAL LEVEL FLOOR PENETRATIONS WATER TIGHT. 11. MAINTAIN MINIMUM 6'-8"x3'-0" CLEAR PATHWAY THROUGH MECHANICAL ROOMS. 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN 1/ 6 / 2 0 1 7 1 1 : 4 2 : 1 1 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 Checker Author BUILDING PERMIT 09 JANUARY 2017 MECHANICAL LEVEL HVAC PLAN M-331 SCALE: 1/8" = 1'-0"M-331 1 MECHANICAL LEVEL HVAC PLAN LEVEL 01.2 100' - 0" TOP PLATE 110' - 0" LEVEL 01 98' - 0" 2 M-504 141312 HRU-06 L 6640 LEVEL 01.2 100' - 0" TOP PLATE 110' - 0" LEVEL 01 98' - 0" 1 M-504 E F H LJ SCU-06 EF-17 HRU-06 LEVEL 01.2 100' - 0" GYM ROOF 130' - 0" TOP PLATE 110' - 0" LEVEL 01 98' - 0" LEVEL 02 109' - 6" GYM CLERESTORY 118' - 0" KGC.2A.3 AHU-03 AHU-05 AHU-06 AHU-07 AHU-08 RFH-01 EF-02 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN 1/ 6 / 2 0 1 7 1 1 : 4 2 : 1 7 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 BB EO BUILDING PERMIT 09 JANUARY 2017 MECHANICAL SECTIONS M-504 SCALE: 1/8" = 1'-0"M-504 1 TYP CLASSROOM MECH ROOM SECTION - LOOKING EAST SCALE: 1/8" = 1'-0"M-504 2 TYP CLASSROOM MECH ROOM SECTION - LOOKING SOUTH SCALE: 1/8" = 1'-0"M-504 3 MECH LEVEL SECTION - LOOKING SOUTH LEVEL 01.2 100' - 0" TOP PLATE 110' - 0" LEVEL 01 98' - 0" LEVEL 02 109' - 6" GYM CLERESTORY 118' - 0" 3 M-50411.1 2 LEVEL 01.2 100' - 0" GYM ROOF 130' - 0" TOP PLATE 110' - 0" LEVEL 01 98' - 0" LEVEL 02 109' - 6" GYM CLERESTORY 118' - 0" DKGF.8 C.2 A.3D.5 1 M-505 725 POWELL AVE SW SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com NORTH 1 2 3 4 5 6 D C B A 1 2 3 4 5 6 D C B A COPYRIGHT MAHLUM ARCHITECTS, INC. 2011 ORIGINAL SHEET SIZE: 30"x42" ISSUE: PROJECT NO: DRAWN BY: CHECKED BY: ISSUE DATE: EE MARK DATE DESCRIPTION ZONE KEYPLAN 1/ 6 / 2 0 1 7 1 1 : 4 2 : 2 3 A M C: \ U s e r s \ o l s m a c k \ D o c u m e n t s \ _ R e v i t F i le s \ 1 6 M A D M e c h C e n t r a l _ E r i k O . r v t MADRONA SCHOOL (ESD) 9300 236TH ST. SW, EDMONDS, WA 98020 EDMONDS SCHOOL DISTRICT 2015913.00 Checker Author BUILDING PERMIT 09 JANUARY 2017 MECHANICAL SECTIONS M-505 SCALE: 1/8" = 1'-0"M-505 1 GYM SECTION - LOOKING EAST SCALE: 1/8" = 1'-0"M-505 2 HALLWAY COMMONS - LOOKING NORTH