Loading...
07-0699 Plan Review Comments.pdf CE th ITY OF DMONDS • 1215 AN•E,WA98020 VENUE ORTH DMONDS P: 425.771.0220 • F: 425.771.0221 • W: www.ci.edmonds.wa.us HONEAXEB DSD: P•E•B EVELOPMENT ERVICES EPARTMENTLANNING NGINEERING UILDING August 27, 2007 Joe Molina Email: jmolina@tgbarchitects.com RE: PLAN REVIEW COMMENTS FOR PLAN CHECK # 2007-0699 KNUTSON SFR AT 18720 SOUND VIEW PLACE Dear Mr. Molina: I have reviewed the above building permit application for the Planning Division. Before I can sign off on the permit, however, the following information needs to be clarified: Side Setbacks: 1. As you are aware, the side setbacks in the RS-12 zone are 10’. The site plan shows a 10’ BSBL. The front and rear elevation drawings seem to indicate that the outer porch posts do not meet the requirement. While this may be an error generated during reproduction of the plans, please make absolutely certain that all structures (except the roof eves and chimneys) meet the 10’ side setback requirement. Walkway: 2. In order for the garage to be considered attached to the main house, the walkway between the two must have a floor and a roof which is integrated into the main house and garage. Datum Point: 3.Please indicate what datum point was used to perform the height calculations on the site plan along with its elevation. Lot Coverage: 4. It is difficult to determine how the structural lot coverage was calculated. Lot coverage is defined as “the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point 2.5 feet in from the outside edge of a cantilevered roof, whichever covers the greatest area.” As a result, the lot coverage calculations should include the total footprint of the proposed house, garage, as well as the covered porch and patio. Please provide the appropriate proposed lot coverage square footages and the final calculation as a percentage of the total area of the lot. Maximum coverage is 35%. SEPA Review: 5.Please provide the total quantities of cut and fill. If the total amount of cut or fill is proposed to exceed 500 cubic yards, SEPA review will be required and an environmental checklist and the associated fee must be submitted. Garage Interior: 6. Please submit building plans for the garage structure. Accessory Dwelling Unit: 7. If it is the homeowner’s intent to establish the space over the garage as an accessory dwelling unit at the present time, an application for an ADU must be submitted to the City along with the associated fee. In lieu of that review, the City will require a statement be recorded at the County indicating that the homeowner is aware that an ADU permit would be needed to allow that use in the future. Geotechnical Report: 8.The geotechnical report submitted by Otto Rosenau & Associate, Inc. appears to address the requirements of ECDC Sections 23.40 and 23.80 (Environmentally Critical Areas – General Provisions and Geologically Hazardous Areas, respectively) regarding the subject site. The report indicates that the 66-foot setback from the property line (79 foot setback from the top of the steep slope) is appropriate for the proposed development. The setbacks listed on the site plan do not match those mentioned in the geotech report. Please update the site plan to show the setback recommendations of the geotechnical engineer’s report. Please submit three copies of your updated site plan (one of which must be 8.5” by 14” inches or smaller) and two sets of any updated pages of the building plans.Please make all submittals to Marie Harrison, your Development Services Permit Coordinator, Monday through Friday, 9:00 am to noon or 1:00 pm to 4:00 pm. If you have any questions, please contact me at (425) 771- 0220, ext. 1330. Sincerely, Mike Clugston Planner, Development Services Department