Loading...
12-0257 Plan Review Comments #2.pdfCITY OF EDMONDS • 121 5th AVENUE NORTH • EDMONDS, WA 98020 PHONE: 425.771.0220 • FAX: 425.771.0221 • WEB: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT: PLANNING • BUILDING May 8, 2012 Jeff Huffman ntocars@yahoo.com RE: PLAN REVIEW COMMENTS #2 FOR PLAN CHECK # 2012-0257 PORCH AT 23814 841H AVE. W Dear Mr. Huffman, I have again reviewed the above building permit application for the Planning Division. Before I can sign off on the permit, however, the following information needs to be clarified in a written response. The first comment was issued in response to the April 10 submittal. The other comments are based on the May 7 resub and come directly from Handout B61. If you need assistance with preparing drawings for resubmittal, please contact a Permit Coordinator here in our office: True and Accurate Plot Plan: While this building permit is only for replacing the front porch, a true and accurate site plan showing everything on the site is required — fences, sheds, decks, etc. Handout B61 describes what other information is required to be submitted as part of a complete application, including height calculations (http://www. edmondswa. gov/imagesICOEIGovernment/Departments/Development Services/Building Division/Forms Hondo uts/861-SFR REMODEL -ADD. pd. A critical area checklist has already been completed for the site (CRA-2003-0059) and does not have to be submitted again. 2. Show all the following information on the plot plan: a. Property owner's name, tax account parcel number and street address. b. North arrow designation, Scale 1"= 20' and property line dimensions. c. Streets, approaches, driveways, sidewalks, alleys, easements (public and private), paved areas, street dedications and adjacent City right-of-way (developed or undeveloped). d. Existing water courses of any size (i.e., streams, creeks, ponds, ditches, etc.). e. Dimension all buildings and structures (label them existing or proposed), indicate setback distances from property lines, call out lot area and lot coverage. f. Accessory structures and projections, decks, porches, hot tubs/pools, cantilevered structures, chimneys, eave lines, breezeways, patios, sheds, fences, etc. g. Building height calculations for additions. h. Impervious area calculations. Side sewer stub location and proposed sewer lines, water meter location, water service line location, gas, cable and phone lines, fire hydrants, telephone poles, utility transformers. 3. Show all of the following information on the elevation view: a. Front, rear, sides, average grade and finished floor and roof elevations. b. Roof overhangs, decks, porches, stairways, walkways, breezeways, cantilevered structures, chimneys, roof decks, guardrails, handrails, landings, stairs, siding, roof material, etc. c. Show location and size of windows, doors, sliders, skylights, etc. d. Show actual and maximum height of the residence taken from the average grade as determined by the height calculations. 4. Perform the height calculations as follows: a. Stake out the smallest rectangle within the boundaries of the site, that encompasses all four corners of the proposed building at original, undisturbed soil. Include decks when covered by a roof and projections such as bay windows. Chimneys and eaves are exempt if they project no more than 30 inches. Note, detached structures must have separate height calculations. b. Select a datum point to establish a starting mark to compute height calculations. The datum point must be a permanent point of reference and be located off site (i.e. top of a manhole cover, fire hydrant, or street monument). Reference the datum point at elevation +100. c. Calculate the difference in elevation at each building corner of the rectangle above or below the datum point mark of +100. d. Add the four corner elevations and average --this figure is the average grade. e. Add 25 feet to the average grade for a single family residence. This figure is the maximum height allowed at the proposed location. f. On the plot plan show the grade elevations at each corner of the building rectangle, the datum point grade, the original grade, the average grade, the actual height and the maximum building height. g. Height field verification shall be done by the applicant's agent/contractor and 'observed' by the building inspector. The agent/contractor shall set up the equipment; establish the datum point and the point of average grade. These items must be consistent with the approved plan. All referenced code sections are available at the following website: http://www.mrsc.org/mc/edmonds/Edmondsnt.html. Please submit three copies of your updated site plan (one being reduced size of 11 x17 or smaller) and two sets of any updated sheets of the building plans. Please make all submittals to a Permit Coordinator, Monday through Friday, 8:00 am to 4:30 pm. If you have any questions, please contact me at (425) 771-0220. Sincerely, Pak , Mike Clugston, AICP Associate Planner