20070723094446.pdfDATE: July 23, 2007 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Tiffany Bui FAX: 425-640-5830 FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit #2006-0556 Project: Bui — Single Family Residence Project Address: 16105 75th Place West During review of the revised plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Theresa Umbaugh, Permit Coordinator. 1. Site Plan: a. The revised site plan cannot contain less information than the original approved site plan. Many items have been grayed out and did not print clearly on the revised plans, or are missing entirely (such as labels throughout the plan, property lines, finished grades, driveway, setback lines, easement lines, etc.). Relabel "existing rock retaining wall" as "new" (rather than existing). b. Clearly show original and proposed grades. c. Provide bottom wall elevations on the plans for the new rockeries. 2. Structural calculations are required for the rockery. Rockery construction detail and calculations must be stamped and signed by the Structural Engineer of Record. Details must be cross- referenced to the site plans. 3. Submit Special Inspection Reports from the Geotechnical Engineer of Record for rockery construction. 4. Submit revised Civil and Landscaping plan sheets addressing the changes made to the approved plans.