20071212152113.pdfof Eby City of Edmonds r PLAN REVIEW COMMENTS BUILDING DIVISION Fsr i g90 (425) 771-0220 DATE. December 12, 2007 TO: Halil Moric 2251793 rd Place W Edmonds, WA 98020 FROM: Ann Bullis, Assistant Building Official 6v— RE: Plan Check # 2007-1176 Project: Fire Damage Repair Project Address: 22517 93`d Place W During review of the plans for the above noted project, it was found that the. following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Marie Harrison, Permit Coordinator. Many of these items were noted in the correction notice dated 11/2/07. 1. Clearly show on the plans specifically which areas will be repaired/altered. 2. Revise written scope of work to note the specific repairs to be made in each area of the house, garage and ADU. List all work to be done under this permit. 3. The plans you have submitted do not show the laundry room that was added within the garage. The City also does not have permits for this room addition within the garage area. Include it with this permit and provide construction details/information, or show on the plans that the room will be removed. 4. Note on the floor plans if the garage will be heated or unheated (per previous discussion in the field). If heated, provide energy calculations and provide window and overhead door U -values that comply with the energy calculation requirements. 5. The location of the furnace and water heater shown on the plans does not appear to be the actual location that they were installed. Revise plans. 6. Smoke detectors in the dwelling and accessory dwelling unit must be replaced. Note on the plans. NOTICE TO PERMITTEE AND/OR OWNER DO NOT REMOVE PARTIAL APPROVAL [ff CORRECTON REQUIRED F1 ENFORCEMENT VIOLATION Owner i l - Permit Number & - Job Address�� �1 q3 7 f 1r, W Site Contact hyt4 Ii ❑ WORK DESCRIBED BELOW HAS BEEN INSPECTED AND IS APPROVED ❑ APPROVED PLANS AND JOB CARD MUST BE AVAILABLE TO INSPECTOR ON SITE ❑ CORRECTIONS LISTED BELOW MUST BE MADE: BEFORE WORK CAN BE APPROVED AND/OR THE NEXT PHASE OF WORK IS STARTED 4713,"rt7 PJ Fri FT ❑ RECALL FOR INSPECTION ❑ $50 REINSPECTION FEE MUST BE PAID PRIORTO INSPECTION REQUEST ❑ STOP WORK -UNTIL AUTIIORIZED TO CONTINUE BY CITY INSPECTOR ❑ NO PERMIT -STOP WORK -REMOVE CONSTRUCTION OR OBTAIN PERMIT AND MAKE WORK COMPLY WITH ALL APPLICABLE CITY CODES • A building permit is required for repair of the fire damaged construction. Submit 2 sets of plans clearly showing what areas will be repaired. • Provide a details written scope of work of the specific repairs that will be made. • Provide a copy of the itemized bid authorized by the insurance company for the repair work. + Replace f -joists that were damaged (including those that are discolored), including nailing of the floor sheathing to the top of the new [-joists (minimum fastener spacing per Table R602.3(l)) and blocking; OR provide repair plans/details stamped and signed by a State licensed Professional Engineer, and the engineer must also determine which joists must be repaired per his/leer design. • Provide pressure test for existing gas line and repair as needed. • Replace burned or removed insulation. • Insulate exposed heat duct in garage with RS insulation. • Replace damaged or removed doors and windows. • Replace B -vent and connector for water heater and furnace from single wall to double wall and replace exposed fire damaged portion of vent in garage. • Replace sheetrock. amd provide required fire separation between garage and dwelling. • Obtain electrical permit for repairs from State Labor and Industries • The owner expressed interest in having the garage as a heated space. Clearly show this change on the repair plans, and submit energy worksheets and U -value information for overhead doors and windows showing.code compliance. + Remove window opening cut into wall between dwelling and garage. THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED TO BE CORRECTED WITHIN -30 CALENDAR DAYS OR PENALTIES MAY BE APPLIED_ FOR INSPECTION CALL 425-771-0220 XBuilding ❑ Planning ❑ Engineering White: Permit File Pink: Enforcement ❑ Fire ❑ Public Works x Date - Buff.- Applicant