20090514143532.pdfDATE: 5/14109 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Beeler 515 Seamont Lane Edmonds, WA 98020 RE: Plan Check: BLD20090259 Project: Addition Project Address: 515 Seamont Lane During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a Permit Coordinator. 1. Provide a building section. This would be similar to a detail, except it will need to show from the bottom of the foundation to the top of the roof sheathing. This should include the following: a. Dimensions on floor plan, details, etc b. Foundation reinforcement: i. min.l# 4 bar in footing with 3" clear to earth ii. 144 bar within the top 14" of the stem wall. iii. 144 standard vertical hook at 48" o.c. c. Minimum 18" footing depth below grade for frost protection d. Pressure preservative treated wood in contact with the concrete (mudsill) e. Minimum %2"x10" anchor bolts @ 6' max. o.c., and at least 3-1/2" , but no more than 12" from the ends of the mudsill. f. Stud species, grade, size and spacing e.g. 2x6 #2 DFL@16" o.c. g. Insulation type and R value in wall and ceiling. h. Wall sheathing: material and fastening i. Vapor barrier/ house wrap material j. Roof sheathing: material and fastening 2. Exterior wall panel lengths used as brace panels (typically at the corners of the addition) that are not at least 48" in length will need to be built as an alienate brace panels. Attached to this memo is a typical brace wall panel drawing, which we accept in the City of Edmonds. 3. The roof framing drawing is missing some information: a. Is the ceiling flat or vaulted? b. Are rafter ties, collar ties to be used? If so, at what height -plate line or above? c. If the ceiling is proposed to be a full vault, then a ridge beam, e.g. 4x12 #2 DFL, and would normally be framed with 2x12s to allow room for the required R-30 in a vaulted ceiling. d. Provide a rafter detail at the top of the wall to see the required bearing (birdsmouth cut) and connection ( Simpson H2.5 or equal, min.) 4. Header species, size, grade and locations, e.g. 4x10 #2 DFL at all bearing openings, unless noted otherwise. 5. The stem wall at the area adjacent to the entry stoop is required to have a footing inder it, minimum 12" wide, 18" below grade, with the typical rebar requirements. If you propose to saw cut the width of the stem wall, then excavate for the required depth and width, form up for the stem wall on top of the existing slab, indicate so on the plans and have the detail show it. Pat Lawler patrick.lawler@cl.edmonds.wa.us Plans Examiner 425 7710220 x1703 Page 2 of 2 1 -story Structure (IRC R602.10.6) NOTE: This panel may be used in place of a braced wall panel required by IRC R602.10.4. For all other wall bracing that does not meet R602.10 lateral calculations stamped and signed by a Washington State Licensed Professional Engineer must be provided. #4 rebar top an L:\tamplbuildlnpandoutVane0abwp.vsd — 8104 Minimum 318" thick plywood sheathing nailed with 8d common or galvanized box nails at 6" o.c. edges and 12"o.c. field. ,wn with min. . uplift Y " anchor bolts embedded spaced at panel quarter nstalled per IRC R403.1.6 Continuous Foundation ATTACHMENT F1