Loading...
20110721160002991.pdfRIPTION Page Number_ Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercia[/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada of ., QESIgb EO (F) CSA 2.6b ANSI Z83.8b Reznor® V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial] industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 ® heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, mufti -try direct spark ignition with 100% lookout, pres- sure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuli board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look —both Inside and out Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled comer to know you have a genuine Reznor unit by Thomas & Betts. FEATURES • Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commercialfindustriai heating application ° 82-83% Thermal efficient — TOP In its classl . 50-60°F Rise range • TcoREz® titanium stabilized aluminized steel heat exchanger • Patented" TcoRE20 single burner combustion system including a one-piece burner assembly e 115/1/60 Supply voltage ® 115 Vott open fan motor with irternal overload protection ° Transformer for 24 -volt controls • Integrated circuit board with diagnostic indicator lights • Multi -try direct spark ignition with 100% lockout ° Fan relay (included on the circuit board) ® Single -stage natural gas valve (field adjustable for operation to 9,000 ft. elevation) • Vibration/noise isolated fan and venter motors — designed for low noise operation a 2 -pt and 4 -pt Suspension — standard on all sizes • External terminal strip for 24 -volt wiring o External gas connection o Full fan guard — engineered for safety e Improved cabinet design with teas visible hardware and a NEW Reznor appearance . FEATURES - o Single -stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation) INSTALLED ® 7Wo-stage natural gas or propane gas valve - Sizes 60.400 a 409 or 316 Stainless steel heat exchangers ° 208 or 230 Single phase voltage e Totally enclosed fan motor (Sizes 30-250, 115V only) e Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) " U.S. Patent No. 6,889,686 (Version H) Page 8 Page Number of OPTIONAL FEATURES - e Ventcap FIELD INSTALLED a Thermostat e Thermostat guard with locking cover e Vertical louvers - new design e Downturn nozzle kits - new design e Gas conversion kits (natural and propane) e Master/Slave controls for zoning up to six units e Ceiling suspension kit - Sizes 30-125 e Hanger kits for 1" pipe e Stepdown transformer (for 230/3 and 460/3 supply voltage) e Manual shutoff valves TECHNICAL DATA Model UDAP Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 BTUH 30,000 45,000 60,000 75,000 105000 120000 150000 175000 200,000 225,000 250,000 300,000 350,000 400,000 Input Heating Capacity 1 1h 8.8 13.2 176 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency (%) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating I BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 Capacity_" kW/h 7.2 11.0 14.6 18.3 25.6 29.2 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection Natural 1/2 12 1/2 1/2 1/2 12 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 (inches) a Pro ane 12 12 1/2 1/2 1/2 12 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 _ Vent Connection Size c (inches 4 4 4 4 4 4 5 5 5 5 5 6 6 6 diameter) Control Am 24 volt 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Am 115 volt 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maxi urn Over Current Protection 15 15 15 15 15 15 15 15 15 15 15 20 0 20 20 Normal Power Consumption 109 1555 155 217 276 354 392 392 491 747 747 1086 1086 1086 watts Discharge Air Temperature Rise 50 55 60 60 60 60 60 60 60 60 60 60 60 60 °F CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 Air Volume MI/minute 12.9 17.8 21,8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening tt' 0.96 0.96 1.26 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 Area Mz 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 022n 0.02 0.03 0.03 0.06 1/30 120 1/6 1/6 1/6 114 114 1/2 12 1/2 Fan Motor HPE Endosed 0.06 0.06 006 0.06 114 1/4 1/4 1/4 114 114 114 112 1/2 12 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter inches 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dB5 @ ft 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net lbs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 Weight k 24 27 30 33 44 1 46 78 85 85 92 98 122 133 139 Approximate Ship Ibs 61 66 74 79 118Wei 123 204 219 219 245 257 321 346 358 ght k 27 30 33 36 54 56 93 100 100 111 117 146 157 163 CSA rating for attitudes to 2000 ft. ° Size shown Is for gas connecrlon to a singre stage gas valve, not supply line size. ° Smaller or larger vent pipe diameters maybe allowed; refer to the venting Installation Manual, Form I -V -PV. M vert dla motor Is dllferentfrom vent connection, reducedenlargem will be field -required. ° MODP= 2.25 x (largest motor FLA)+ smallest motor FLA. Answer is rounded to the nearest oommercalry available circuit breaker. ° All other Information In this table Is based on a heater equipped with s standard 115 volt open fan motor. Form RZ-C-UH (Version H) Page 9 Page Number of ENSI®NS :I UDAP ;' (2mm) 175, 1 20 1/8 138 3/16 1 16 1 23 1 42 1 35 318 1 6 112 1 8 114 1 5 7/16 1 6 12 125 11/16 1 1 318 18 3/16 122 3116 116 3/8 350, 134 1/8 I 4 1 130 I 23 I 42 135 318 117 11161 9 Ill 13/161 7 5116 127 111161 1318 1 8 3116 122 3116 1 16 3116 5 , 175, (511) (970) (406) (584) (1,067) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 00 22ii 250 664 970 559 584 1067 699 332 224 229 165 652 35 208 564 397 0 (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) mansions 1� X350, 0 oz -125 lic N M t 150-400 R - Hanger Dimension for 3/8"-16 Female Thread I •tni 2;pt SuCombuspension - all suspension points P flan Air gid. `• ," ` � � *7 'Suspend the hesteir so Utat the bottom to a m4ohm m o/ 5'(1.5" above the floor, (Version H) Page 10 Hanger 1'0-� T tio mansions 1� • 0 oz -125 lic for 4. -pt t 150-400 •' o 3/8"-16 Female Thread I - all suspension points Ik+ i V ri Line Voltage K jxterna Vent Connection Inlet (connects I (see Technical at circuit board) Connection gid. `• ," ` � � *7 'Suspend the hesteir so Utat the bottom to a m4ohm m o/ 5'(1.5" above the floor, (Version H) Page 10