Loading...
20130730150719346.pdfR FLOOR SPI.0 SITE PLAN SS, -- — ELED - - --------- As part of the Building Permit Submittal :R AS NELSON GEOTECHNICAL ASSOC., INC. OM OF shall provide a disclosure letter, stamped LAZING and signed addressing the provisions of THAN ECDC 23.80 for geologically hazardous BACK UP - INTCONNECTION areas and include the following language: 1E ENERGY INFORMATION- WALL As part of the Building Permit Submittal PLANE J.C. MCDONNELL, ENGINEERING, PC A5.2 shall provide a disclosure letter, stamped 3 SHALL and signed addressing the provisions of ECDC 23.80 for geologically hazardous areas and include the following language: LLOWS: AN IANUAL VG OF 1.5 )F 4 SQ. 1000 BN ,LOSER T INLET. N ALL )WING E .I. )NS �c4 WA4 S �123�IZ 6215 OYAL�' ewes e In her/his judgment the plans and specifications prepared by the structural engineer cmform to the recommendations in the geoteelmleal report. e That the risk of damage to the proposed development, or to adjacent properties, from soil Instability will be minimized subject to the conditions set forth in the report and that the Proposed development will not increase the potential for soil movement. Mtnimized shall mean that the applicant has utilised best available science and commonly accepted -.engineering and architectural practice to minimize, to the extent possible, the risks .associated with development oftheproperty. • The statement shall include, as a condition, an evaluation setting forth the statistical probability (percentage) of earth movement within a 25 year period, the susceptibility of the risk, or hazard to correction, by on-site improvements and the measures taken- to - mitigate the risk or hazard. • The geotechnical engineer shall review the erosion and sediment control plan and provide a statement about the adequacy of the plan with respect to site conditions and report findings. • From the guidelines in the 2007 Landau Summary Report; an identification of landslide hazards applicable to the site, the on-site measures taken to correct or reduce the hazards, as applicable, and, measures taken to mitigate potential impacts from the remaining hazards. • For sites where the hazards are not mitigated or where the risks from deep-seated or large-scale earth movement cannot be practically reduced by individual lot owners, the statement shall identify what hazards could not be addressed by individual lot development. The statement shall specify any risks from earth movement that are not fully mitigated by design measures and render an opinion as to whether the site will be stable within the meaning of the ordinance following installation of all proposed improvements. Further recommendations, signed and sealed by the geotechnical engineer, shall be provided should there be additions or exceptions to the original recommendations based on the plans, site conditions or other supporting data. Mike Mitchell, Owner, Professional Engineer of Mitchell Engineering, Inc. Engineer of record : The snuctmal engineer of record shall submit a disclosure letter or include a drawings that includes the following language: • That he/she has reviewed the geotechnical reports, understands its recommendations, has explained or has had explained to the owner the risk of loss due to slides on the site. • That he/she has incorporatedinto the design the recommendations of the report and established measures to reduce the potential risk of injury or damage that might be caused by any earth movement predicted in the report. • Note any risks, hazards, potential problems from earth movement that are not fully mitigated by design measures. James Thomas, Owner, Architect of Architectural Design Assoc., PS is hereby Designated as the LEAD DESIGN PROFESSIONAL Who has reviewed the geotechnical report, understands its' recommendations and has incorporated into the design the establish measures to reduce the risk of injury or damage form any earth movement predicted in the report. PROJECT LEGEND: IRECTION OF CUT ETAIL DESIGNATION BUILDING SECTION ANNOTATION X. SHEET /-DETAIL DESIGNATION SPI.0 SITE PLAN DETAIL ANNOTATION FRONT & REAR ELEVATIONS SHEET ® SOLID BEARING TO FOUNDATION @ MAIN FLOOR PLAN GIRDER TRUSSES, HIP MASTERS, UPPER FLOOR PLAN BEAMS AND HEADERS (MIN. 2 STUDS) FOUNDATION PLAN 110V SMOKE DETECTOR w/ BATTARY MAIN FLOOR FRAMING PLAN BACK UP - INTCONNECTION Fl 50 C.F.M. CEILING FAN V.T.O. SHEET INDEX: T1.0 TITLE SHEET SPI.0 SITE PLAN A1.0 FRONT & REAR ELEVATIONS A1.1 RIGHT AND LEFT SIDE ELEVATI A2.0 MAIN FLOOR PLAN A2.1 UPPER FLOOR PLAN A3.0 FOUNDATION PLAN A3.1 MAIN FLOOR FRAMING PLAN A3.3 ROOF FRAMING PLAN A5.0 ENERGY INFORMATION- WALL SECTIONS A5.1 CONSTRUCTION DETAILS A5.2 CONSTRUCTION DETAILS S-1.0 STRCUTURAL NOTES AND DETA S-1.1 STRUCTURAL NOTES AND DETA F2 105 C.F.M. WHOLE HOUSE FAN V.T.O. - PROJECT DATA: TAX PARCEL NUMBER: PROJECT TEAM: ZONIN00000103 ZONING OWNERS/CLIENT: RS -12 GEORGE AND GINGER OLSON PROPERTY ADDRESS 3528 102ND PL SE EVERETT WA98208 r 15500 75TH PL W., EDMONDS, WA. 98206 425-337-5046. ARCHITECT: JAMES THOMAS, ARCHITECT ARCHITECTURAL DESIGN ASSOCIATES, PS 2221 EVERETT AVENUE #101 EVERETT WA. 98201 Ph: 48-259-0661 Email: jthomas@arch-design.net STRUCTURAL ENGINEER MIKE MITCHELL, P.E. MITCHELL ENGINEERING, INC. 7821 168TH AVE. NE REDMOND WA. 98052 Ph: 425-%47-1500 Fax: 425-747-5403 Email: mitchellengineering@comcast.net GEOTECHNICAL ENGINEER NELSON GEOTECHNICAL ASSOC., INC. 17311 135TH AVE NE A-500 WOODINVILLE, WA. 98072 Ph: 425-486-1659 Fax: 425-481-2510 khals@nelsongeotech.com CML ENGINEER JOHN MCDONNELL, P.E. JC MCDONNELL ENGINEERING, PC PO BOX 13199 MILL CREEK, WA. 98043 Ph: 425-7440916 Fax: 425-744-0946 Email: jcmcdon2@frontier.com LANDSCAPE ARCHITECT. ARBORIST KEVIN TEAGUE, RLA HARMSEN AND ASSOCIATES, INC 16778 146TH ST SE STE. 104 MONROE, WA. 98272 Ph: 360-794-7811 Fax: 360-805-9732 Email: kevint@harmsen.com CONSTRUCTION TYPE: TYPE VB SPRINKLER SYSTEM: N/A OCCUPANCY: R-3 LEGAL DESCRIPTION:( PARTIAL DESCRIPT SW 1/4 NW 1/4 SEC.05 T 27N R 4E W.M. SEE SHT. Cl FOR COMPLETE DESCRIPTION GOVERNING CODES 2009 INTERNATIONAL RESIDENTIAL CODE WAC 51-51 2009 INTERNATIONAL FIRE CODE W/ WAC 51-54 2009 UNIFORM PLUMBING CODE W/ WAC 51-56, 51-57 2006 INTERNATIONAL MECHANICAL CODE WASHINGTON STATE AMENDMENTS 2009 WASHINGTON STATE ENERGY CODE WAC 51-11 2008 NATIONAL ELECTRIC CODE CITY of Edmonds DESIGN & CONSTRUCTR STANDARDS & SPECIFICATIONS LAND SURVEYOR TOM BARRY, PLS METRON AND ASSOCIATES, INC 307 N. OLYMPIC AVE. STE. 205 ARLINGTON , WA. 98223 Ph: 360-435-3777 Fax- 360-435-4822