Loading...
2013-1105 Swedish Parking Garage.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: November 18, 2013 TO: Scott Harris JRJ Architects Email: sharris@jrjarch.com FROM: Leif Bjorback, Building Official RE: Plan Check: 2013-1105 Project: Swedish Parking Garage th Project Address: 7324 216 St. SW During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.On the cover sheet please change the referenced codes from 2009 to 2012. Also, change “Washington Energy Efficiency Specialty Code” to read “Washington State Energy Code.” 2.The site address is incorrect in the title block of all pages except the cover sheet. Please th change the address to read “7324 216 St SW.” 3.Show the emergency lighting on the plans. IBC 1006.1 4.Show on the drawings emergency signs at the elevator call stations complying with IBC 3002.3. 5.At detail F1/A2.0 change “THIRD FLOOR LEVEL” to read “FIRST FLOOR LEVEL.” 6.On sheet A2.2, the position of the callout for D1/A4.2 suggests a cross-sectional view, however the view shown is an elevation view. Please either correct the callout reference, or provide a cross-sectional view, as appropriate. 7.A 36 inch wide access aisle is required for pedestrian access to the stairwell areas, most of which are immediately adjacent to parking stalls on both sides of these areas. When cars are parked in these stalls there is insufficient width to provide the minimum access. Please modify the plans to show a marked access aisle wherever this configuration occurs. IBC 1017.5 8.On sheet A6.2 revise the section details to show a 12 inch minimum top extension of the handrails at all stair runs. (Several details currently show 11 inch extensions.) IBC 1012.6 9.The construction of the parking structure, and resulting increase in the number of parking stalls on site, necessitates an increase in the number of accessible stalls on site per IBC 1106. It is understood that no accessible stalls will be required or provided within the structure itself, but that additional accessible stalls will be added elsewhere on the property to comply with code requirements. Please provide parking calculations showing the number of stalls on site, the number of required accessible stalls, and modify the site plan to show the locations and signage for the stalls. 10.Please respond to the structural review comments by Beck and Associates dated 10/13/2013. Your response should be addressed to me. 11.Special inspections have been identified for the project. Please complete and return the attached special inspection agreement forms—one for Soils and one for Structural. These may be submitted for review any time prior to the issuance of the building permit. Page 2 of 2