Alder St-523_Michel_SFR_BLD20080474_3.pdf City of Edmonds BLD20080474 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments Permit Application :Date: # BLD20080474 12/03/08 Project Name/Address: 523 – Alder St Contact Person/Address, Fax or E-mail: Michel Construction Inc – michelbz@nwlink.com Reviewer: JENNIFER COLLINS Division: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.us under City Government / Development Services Department / Engineering Division then scroll down to Handouts: rd 3 Review – 12/03/08 nd 2 Review – 11/06/08 st 1 Review – 7/18/08 1)OK 2)OK 3)OK 4)OK 5)OK 6)OK 7)OK 8)OK 9)OK 10)OK DATE E-MAILED 12/03/08 PAGE() 1 City of Edmonds BLD20080474 TH 121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments 11) OK Comments completed by Jerry Shuster, City of Edmonds Stormwater Engineering Program Mgr 12) 12/03/08 - With the information provided it is still not clear whether any overflow from the portion of the trench along the west property line will impact the adjacent property. Also, the Trench Section detail on sheet P3 indicates the bottom of the trench is proposed to be 2 feet 4 inches below grade, but it is not clear based on this information alone whether the infiltrated water from the proposed trench will impact the property to the west. Please provide adequate topography and show the flow paths for both the overflow and the infiltrated water from the trench towards the west in relation to the adjacent property. The overflow water must not flow onto the neighboring property and pool or otherwise impact the property. You must show that the infiltrated water passes under the foundation of the neighbor to the west or otherwise does not impact the property. Adjust the drainage system as as necessary. The next submittal must clearly show that overflow and infiltrated water from the system will not impact the adjacent property to the west. There is also the option of discharging the detention tank to a new catch basin in the right-of-way and then connecting to the City storm system further west on Alder St. Also, the Trench Section detail on Sheet P3 shows a 2 foot-wide trench. The profile on Sheet P3 as well as the plan view on sheet P2 calls out a 2.5'x6' & 3' trench. It appears from sheet P2 that an L-shaped trench that is 6 feet long (2.5 feet wide) along the west property boundary and an additional 3 feet long (2.5 feet wide) along the southern site boundary is proposed. Please, revise the trench detail on sheet P3 to reflect a 2.5 foot wide trench bottom and a detail showing how the perforated pipe is going to be connected at a 90 degree angle within the L-shaped trench. 11/06/08 Previous Comment – Comment was partially addressed. Please provide a detail for the spreader trench (detail 3/P3 was referenced but not provided). Ensure that the discharge from the trench does not impact the adjacent property to the west. If you have any questions please contact Jerry Shuster, Stormwater Engineer Program Manager (425-771-0220 ext 1323) 7/18/08 Previous Comment: Please relocate spreader trench onto south property line so if system overflows the overflow will go into the right of way. Please resubmit 3 copies of the revised site drawings and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 ext 1321 or by e-mail at collinsj@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 12/03/08 PAGE() 2