Loading...
BLD20130482.pdft/ �OF ED11O Inc t8y° CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 05/16/2013 Expiration Date: 05/16/2015 Parcel No: 00513105800900 THOMAS MCDONOUGH 16115 75TH PL W EDMONDS, WA 98026-4525 CONSTRUCT NEW 288 SQ FT DECK VALUATION: $5,760.00 PERMIT TYPE: Residential GRADING: N CYD_SO RETAINING WALL ROCKERY: N FENC 0 X 0 FT.) OTHER: N ------OTHER DESC: NUMBER OF STORIES: 0 NUMBER OF DWELLING UNITS: 0 Permit #: BLD20130482. F_Tg2RM' elm THOMAS MCDONOUGH BRUCE FIARDY CONSTRUCTION & SERVICES 16115 75TH PL W 1005 NE 162ND ST EDMONDS, WA 98026-4525 SHORELINE, WA 98155(425) 772-0646 LICENSE #: BRUCEHC894JC EXP:04/03/2014 PERMIT GROUP: 22 - Deck/Porch/Patio Cover TYPE OF CONSTRUCTION: VB OCCUPANT GROUP: R-3 OCCUPANT LOAD: CODE: 09 ZONE: RS-20 VESTED DATE: LOT #: 2ND FLOOR: 0 BASEMENT: 0 BASEMENT: 0 lST FLOOR: 0 3RD FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 � REQUIRED: N 25 PROPOSED: 35 REQUIRED: W 25 PROPOSED: 62 UIRED: S 10 PROPOSED: 10 HEIGHT ALLOWED:25 PROPOSED:15 SETBACK NOTES: Deck replacement/ex ansion sides 10 min/35 total 1ST FLOOR: 0 2ND FLOOR: 0 ZAGE:0 DECK:84 OTHER:O E 25 PROPOSED: 25+ DS U.. • . ING THE I AGREE TO COMPLY WITH CITY AND STATECATION OF THE LABOR CODE OF THE STA E O WOSHINGTON RELATINGOO WORKMRIZED NBY, NO PER WILL BE EMPLOYED IN VIO COMPENSA"iION INSURANCE AND RCW 18:27. THIS APPLIC �TlfT APERMIT UNTIL SIGNED B/Y' THE%BULL BUILDING OFFICIAL OR HIS/HER DEPUTY AI>ip ALL FEES ARE l Y—v^s 'ice e a i'G �/ I1 LL1•P 7��/ rint Name Date Released By ATTENTION AS BEEN IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING CIO�R�CY TUHASB UNTIL A BEEN GRANTED. INSPECTION NSPEC IBCI I IRCI 10 MADE AND APPROVAL OR A CERTIFICATE OF OTHEq - ONLINE APPLICANT ASSESSOR I BLD20130482 STATUS: ISSUED dation design is conditional subject to inspection of existing site soil conditions. Approval of this foun Retaining Walls must be designed and constructed to resist the lateral pressure of the retained material. Provisions must be made for the control and drainageroyal must be granted by the Building Official prior to use or occupancy: of Final approval on a project or final occupancy approval PP the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. Any request for alternate design, modification, ien must ariance or other specifically requested administrative and be called out and identifed"variance") Processing adopted codes, ordinances or policies must b p cil and shall be paid upon submittal and are non-refundable. fees for such request shall be established by Coun code and for which a variance has not been PP A roval of any plat or plan containing provisions which do not comply with city specifically identified, requested and considered by theappropriate top cod al in accordance with the appropriate provision of city code or state law does not approve any items from the Sound/Noise originating from temporary construction sites as 0 � onit of weekdays�and 10 OOam and 6 OOpmction activity are t on Saturdays, e limits of ECC Chapter 5.30 only during the hours of ll other to 6.0 p excluding Sundays and Fe Holidays. At all a variance hasise be beginating from construction engranted pursuant t ECC 5 30e120 tivities must comply with the noise limits of Chapter 5.30,agrees to indemnify defend and hold Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of of this wha tever nature, arising directly or indirectly from the issuance for this pe itIssvua nth City's abirlity to enforce anyemed to .modify, waive or reduce any requirements of any City ordinance nor limitit shall not be y Y ordinance provision. ONLY. ANY ED. THIS WORK TO BE DONE ON PRIVATE PROPERTY THIS PERMIT AUTHORIZES ONLY THE WO URNS, 81D WALKS, DRINEWAYST COVERSMARQUEES, ETC) WILL REQUIRE SEPARATE PERMISSIONONSTRUCTION ON THE PUBLIC DOMAIN PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) 425) 771-0220 EXT. 1333 ENGEERING (425) 771-0220 EXT. 1326 FIRE (425).775-7720 IN BUILDING ( PRE-TREATMENT (425) 672-5755 RECYCLING (425) 275-4801 PUBLIC WORKS (425) 771-0235 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection bein re nested, Contact Name and Phone Number, Date Prefereed, and whether you refer mornin or afternoon. J B-Isolated Footings/Piers B-Framing B-Building Final �L APP It auhfl� ` of E D hj r.. a DEVELOPMENT SERVICES ESLHA BUILDING PERMIT go,APPLICATION FORM F F 90 121 5`h Avenue N, Edmonds, WA 98020 - � City of Edmonds Phone 4?,5.771.0220 2 Fax 425.771.0221 E REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PLEAS #: • �* I PROJECT ADDRESSr(�reet; mite # Parcel City State, Zip): .r;VQU goU Project Valuation: S of #: • ision/L -•�. Subdiv Fax: * 3 . APPLICANT; owif Q tfi v 6 _ ess: _ ' ddr E Mail A Address (Street, City, State, %f Phone: Rax: PROPERTY OfNER: / ` E-Mail Address: Add ress(Str City, J�te, Zip) b l / Phone: Fax:. LENDING AGENCY: E-Mail Address: Address (Street,State, Zi City, 1?): , Phone: Fax: CONTRACTOR:* ✓/Ca LG . if' cc %CLAY .5�� /1 ilG q' License #/Ex . Date: -,+- ,� �� Address (Street, City, State, Zip): 56 13p,LJM- J /�� 'Contractor Hors( have n valid Ciq� of E rnonds business license prior to doing work in the City Bu iness License #/Exp. ,ate: 775.2515 City. Contact the City Clerk's Office at 425. DETAIL SCOPE OF WORK: PROPOSED NEW SQUARE FOOTAGE FOR TffiS PROJECTc s . ft. Select Basement Type: ❑Finished 0 Unfinished Basement: s ft Garage ort: s ft. 1st Floor: Declr/Patio:' s . ft. s . ft. s ft 2" d Floor- Other: i Retaining Wall: ❑Yes ❑ No i i I declare tntder penalty of perjury Incas that the inform auatithorized V provided the p►�op colnplete, mid that I one el fl wrtyowiter to tbiidt n penidt npplic do t to the property owner or dull nut nget t the City of Edmonds. CONu weer ❑ Agent/Other (specify): Print Name: C -O% 3 Date: .2 Signature: (/ Updated: 9 l2010 _ _ _ n,,;,a; —TJew drive\ESLHAApp1ication.doc Inspection Comments PERMITTRAX BL D2 130482 22 - Deck/Porch/Patio Cover Applied: 05/08/2013 Issued: 05/16/2013 Expires: 05/16/2015 Address: 16115 75TH PL W, EDMONDS .INSPECTOR. 1114 - B-Isolated Footings/Piers *' 06/04/2013 LAWLER CMP Comment: K 1142 - B-Framing 07/12/2013 LAWLER CMP . Comment: L 1158 - B-Building Final 07/12/2013 LAWLER CMP Comment: 12/9/2013 12:31:49 PM 11 Page 1 of 1 v , no gal M (3eotechnical Engineering and Earth Sciences fi April15, 2013 STREET FILE Thomas and Monica McDonough 16115 75th Place West Edmonds, WA 98026 RECEIVED APR 2 6 2013 SUBJECT: GEOTECHNICAL ADDENDUM DEVELOPMENT SERVICES Proposed Deck Replacement COUNTER 16115 75th Place West Edmonds, Washington Project No. 12-130-02 Dear Thomas and Monica, We have previously performed a geotechnical evaluation for a proposed new garage on your property and we understand that you now propose to expand the scope of that project to include replacementof your existing deck on the west side of your residence. This addendum supplements our previous report dated 8/28/12 and our previous letter dated 11/12/12 and includes our evaluations and recommendations for foundations for support of the proposed new deck. Recommendations of our previous report and letter remain applicable. Our supplemental work was performed in accordance with the scope and conditions of our proposal dated March 29, 2013. Your builder, Rob Michel has provided us with a proposed deck replacement plan which we used as a reference for our site explorations and evaluations. Review of the plan indicates that the proposed new deck will be located within the previous deck site but will extend about 7 feet further to the south. For the purpose of our evaluation we have assumed that maximum deck column loads will be about 5 kips or less. If actual structural loads exceed this estimate our office should be notified. P.U. Box 276, Issaquah, WA 98027-0276 • Phone: (425) 397-4228 Fax (425) 391-4228 McDonough April 15, 2013 SCOPE OF WORK Our geotechnical reconnaissance included site reconnaissance, site explorations, review of data, engineering analyses and evaluations and the preparation of this report. The scope of work included the following specific tasks: o Reviewed our previous report and letter. o Performed a site reconnaissance to observe conditions the deck site. o Site. explorations were performed via hand auger borings. Two borings pits were drilled at locations near the proposed deck site (see Figure 5). Both of the borings extended to depths of 7.5 feet below the surface. .o Performed engineering evaluations of the surface and subsurface conditions observed. o Evaluated the subsurface conditions for foundation support. o Evaluated possible landslide hazard mitigation measures. o Prepared this geotechnical report summarizing our findings and recommendations for site development. DECK SITE CONDITIONS Our observations of the deck site were made on 4/8/12. The deck site is located on the west side of your existing residence at the northwest corner. Topography at the deck site is essentially flat at the lower house level, extending about 30 to 40 feet west of your existing house (see Figure 3 of our 8/28/12 report). We did not observe any evidence of current landslide activity such as ground cracks or fresh slide scarps or scars in the deck site area or on the property in general. Vegetation at the deck site included lawn grass and two nearby ornamental trees. Subsoils Shallow subsoils were explored with two hand auger borings excavated at the approximate locations shown in Figure 5. Logs of the hand auger borings are presented in Appendix A. Project No. 12-130-02 Page 2 McDonough April 15, 2013 Soils observed in the hand auger borings included about 1 foot of. topsoil and the underlying soils were generally classified as clayey silt with occasional sandy silt lenses. The subsoils were soft to firm at the surface but became firm to stiff at a depth of only about 1 foot and generally became more stiff with depth. Sandy silt lenses were encountered at the HA-1 location at about 4.5 to 5.5 feet and again at 6.5 feet. r Ground Water No surface seepage was observed at the deck site but we noted seepage in the lower pathway steps south of the residence at an elevation about 2 to 4 feet above the deck site. Ground water was measured in both borings at depths in the range of about 4 to 4.5 feet. Soils were classified as moist to very moist becoming very moist to wet with measured moisture contents ranging from about 28 to 44 percent of dry weight. SITE EVALUATIONS Deck Support Considerations In our opinion the subsoil conditions encountered in our explorations are suitable for spread footing foundations for support of the proposed new deck. Conventional spread footings/grade beams founded on undisturbed firm to stiff natural soils should provide adequate support -for the proposed deck with tolerable settlements. Large Ancient Landslide Hazard As indicated in our previous report, the site is located within the North Edmonds Earth Subsidence and Landslide Hazard Area (ESLHA) a hazard area established by the city of Edmonds due to an existing very large, deep seated ancient landslide area that affects your property and neighboring properties. The reader should refer to our previous report for our further evaluations of the ancient landslide stability. Local Stability Hazards The proposed deck site is within a flat lying area bordered on the west by a -gentle west facing slope that is only about 6 to 8 feet in height with slope gradients in the range of only about 8 to 14 percent based on the topographic map provided to us. The proposed deck will be set back about 20+ feet from the adjacent gentle slope. Considering the small height and gentle gradients of the slope, in our opinion the existing gentle slope west of the deck site has adequate static stability (Safety Factor exceeding 1.5) and the proposed deck site also has adequate stability. Also as indicated in our previous report the risk of slide debris impacting the property from a slide above the property is considered low and considering that the house is immediately upslope of the deck, the risk for the deck site is considered extremely low. Project No. 12-130-02 Page 3 McDonough April 15, 2013 ESLHA Hazard Mitigation Considering that the proposed new deck will be appurtenant to your existing residence which pre -dates the establishment of the ESLHA and that the new deck is a replacement for the existing deck, we understandthat an argument could be made that no special mitigation for possible future movements of the ancient landslide need be considered for the new deck. However, as indicated in our previous report, the ancient landslide does exist and you must be willing to accept the risk that the proposed replacement deck may be damaged by future movements of the landslide (just as the existing deck and residence could be damaged). If the new deck is to be designed to mitigate future landslide movements, in our opinion, the only reasonable method of mitigation against the risk of future movements is by providing a sufficiently stiff foundation system adequate to withstand differential displacements of the subgrade and minimize distress to the deck. For slide movement mitigation the foundation system should be designed to be capable of withstanding differential subgrade offsets that would result in loss of support under a portion of the new deck footprint. The differential subgrade offsets should be assumed to undermine 1/4 of the deck in the north -south (longitudinal) direction and the new deck supports should be assumed to potentially drop at least 1 foot relative to the residence structure. Shallow Foundations Without Landslide Mitigation If the deck is not to be designed to mitigate possible future landslide movements, conventional spread footing pads founded on undisturbed firm to stiff natural soils should provide adequate support for the proposed deck. All footings should be founded at least 18 inches below the lowest adjacent final grade. Square footings should be at least 24 inches wide and continuous footings should be at least 1.8 inches wide. Footings may be designed based on an allowable vertical bearing pressure of 1000 psf. Where fill soils and/or unsuitable loose/medium dense natural are encountered, footings should be deepened as required to penetrate the fill and unsuitable soils to bear on undisturbed firm to stiff,natural soils. Settlement of spread footing foundations is expected to be within tolerable limits. for this structure. For example, the estimated settlement of a square footings carrying loads up to 5 kips, are expected to be on the order of .Y to '/ inch. Maximum differential settlement within the proposed deck is expected to be on the order of % inch. Settlements are expected to occur primarily during construction. For lateral design, resistance to lateral loads car`. be assumed to be provided by friction acting at the base of foundations and by passive earth pressure. A coefficient of friction of 0.3 may be assumed with the dead load forces in contact with onsite soils. An Project No. 12-130-02 Page A McDonough April 15, 2013 allowable static passive earth pressure of 150 psf per foot of depth may be used for the sides of footings poured against undisturbed natural soils. The bearing values indicated above are for the total dead load plus frequently applied live loads. If normal code requirements are applied for design, the vertical bearing values may be increased by 50% for short durations of loading which will include the effects of wind or seismic forces. Allowable lateral passive pressures may be increased by 33% for wind and seismic forces. Shallow Foundations - With Landslide Mitigation Properly designed shallow foundation system consisting of a continuous spread footing and stiff grade beam with low bearing pressure (1000 psf) is considered feasible foundation system that could minimize structure distortions due to differential subgrade offsets across the site (from landslide movements). It should be noted however that even a properly designed stiff foundation system cannot prevent all structure displacements and damage resulting from subgrade offsets under the site. All foundation systems should be designed by a qualified licensed structural engineer. For mitigation of potential landslide movements at the site, the deck foundation system should be designed to be capable of supporting the structure with differential subgrade offsets that would result in loss of support under portions of the deck. Two separate undermined conditions should be considered in structural design: 1) subgrade offsets undermining 1/4 of the deck in the north -south (longitudinal) direction and 2) subgrade offsets resulting in a drop of the new deck foundations of .at least 1 foot relative to the residence structure (east -west direction). When designing for the subgrade offset conditions the maximum foundation bearing pressures should not exceed 1500 psf. Shallow foundations should have a minimum width and depth of 18 inches and should be supported on undisturbed firm to stiff natural soils. If soft or otherwise unsuitable soils are exposed at minimum footing depth, the footing excavation should be deepened as required to expose.suitable bearing soils. Settlement of spread footing foundations is expected to be within tolerable limits for this structure. For example, the estimated settlement of a footing carrying a loads of 1 kip/ft is expected to be on the order of % to Y2 inch. Maximum differential settlement within the proposed deck is expected to be on the order of % inch. Settlements are expected to occur primarily during construction. For lateral design, resistance, to lateral loads car be assumed to be provided by friction acting at the base of foundations and by passive earth pressure. A coefficient of friction of 0.3 may be assumed with the dead _ load forces in contact with onsite soils. An allowable static passive earth pressure of 150 psf per foot of depth may be used for the sides of footings poured against undisturbed natural soils. Project No. 12-130-02 Page 5 McDonough April 15, 2013 The bearing values indicated above are for the total dead load plus frequently applied live loads. If normal code requirements are applied for design, the vertical bearing values may be increased by 50% for short durations of loading which will include the effects of wind or seismic forces. Allowable lateral passive pressures may be increased by 33% for wind and seismic forces. _r Observations and Testing During Construction Recommendations presented in this report are based on the assumption that soil conditions exposed during construction will be observed by our office so that any necessary design changes or supplements may be made. All footing/grade beam excavations should be observed prior to placement of steel and concrete to see that they have penetrated into bearing soils and that excavations are free of loose and disturbed materials. CLOSURE - This letter was prepared for specific. application to this project and for the exclusive use of Thomas and Monica McDonough and their representatives. The findings and conclusions of this report were prepared with the skill and- care ordinarily exercised by members of the local geotechnical profession currently practicing under similar conditions. We make no other warranty, either express or implied. Variations may exist in site conditions between those described in this report and actual conditions encountered during construction. If conditions encountered during construction appear to be different from those indicated in this report, our office should be notified. Sincerely, GEOSPECTRUM CONSULTANTS, INC. c James A. Doolittle Principal Engineer attachments: Figure 5 Appendix A dist: 1/Addressee (via email) 2/Rob Michel Project No. 12-130-02 Page 6 r r < lm� \ s` m `` • N v CL •. . N E m Ca v t a + w + 08 ^. .i � t + D a� N CoMr- zv ._ N U, co, HA-1 -f. Ga _ HA-2 n a z go G U 0) Proposed n!% ni cV New Deck Co CU a o J< sC ---- O rs '� ;- �� a Cr r + � .-- cV 'a 0 + ` • 0 04 90 !!S + N sb i5 N .. 4-4 00 SITE DEVELOPMENT AND EXPLORATION PLAD GEOSPECTRUM CONSULTANTS, INC. Proposed Deck Replacement Ib �n• Y' 16115 75th Place West Edmonds, Washington Gaot®chn/co/ Eng/n�Nng and EoIth Sc/anoos Proj. No.12-130 Date 4/13 Figure 5 APPENDIX A FIELD EXPLORATION Our field exploration included a site reconnaissance and subsurface exploration program. During the site reconnaissance, the surface site conditions were noted, and the locations of the hand auger borings were approximately determined. The hand auger borings were approximately located using the existing structure as a reference. Elevations at the boring locations were estimated based on the topographic map provided to us (see Figure 5). The borings were advanced. using hand excavation tools. Soils were continuously logged and classified in the field by visual examination, in accordance with the ASTM Soil Classification system. Penetration tests were performed in the hand auger borings using a 1/2-inch diameter penetrometer and a 27.5-pound driving hammer falling 24 inches. Recorded blows for 12-inches of penetration are shown on the hand auger boring summary sheets. Logs of the hand auger borings are presented on the boring summary sheet A-1. The hand auger boring summaries include descriptions of the soils and pertinent field data. Soil consistency and moisture conditions indicated on the logs are interpretations based on the conditions observed in the field. Boundaries between soil strata indicated on the logs are approximate and actual transitions between strata may be gradual. HAND AUGER BORING NO. 1 Logged by JAD Date: 4/8/13 Depth Blows Class. Soil Description 0 OL Sod and topsoil 1 MI Clayey Silt 4 CL 3 4 4 ML Sandy Silt, very fine 5 5 Clayey Silt 6 7 4 ML Sandy Silt Maximum depth 7.5 Logged by JAD Date: 4/8%13 Depth Blows Class. Soil Description 0 OL Sod and topsoil 1 �L L Clayey Silt 2 3 3 4 3 5 4 6 Elevation: 74' Consistency Moisture Color W(%) Comments soft/ moist Bark noose o ve most rown firm It brown sotiff � c rag- 32.5 27.5 `1oist wet 35.1 wet 38.1 ro�i rec� rown Water at 53" after 45 min. IGER BORING NO. Elevation: 74' Consistency Moisture Color W(%) Comments soft/ I moist I dark firm t -- ra - grown sti & red- 35.2 - brown ................... very 40.3 - wet 44.1 7 10 stiff . Maximum depth 7.5 ft. Groundwater at 55" after 15 min. GEOSPECTRUM CONSULTANTS, INC. Proposed Deck Replacement 16115 75t' Place West Geotechnica! Engineering and Earth Sciences Edmonds, Washington Proj. No. 12-130 Date. 4/13 Figure A-1 G