Loading...
BLD20171150 (2)Ali- .0of E Mo4,- N CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 - PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 08/25/201.7 r � � -- -- — - - -- - - - - Pemdt #: BLD20171150 BUILDING PERMIT I Expiration Date: 02/26/2018 _Project Address: 22924 102ND PL W, EDMONDS+ Parcel No: 00610700100500 Rel , y . . a , CHEEKS; LOT 3 MOORE FIRE PROTECTION MOORE FIRE PROTECTION C/O INVESTMENTS LLC HIGHPOINT C/O TRACY MOORE C/O TRACY MOORE 14915 102ND AVE NE 14401 ISSAQUAH HOBART RD SE ST 14401 ISSAQUAH HOBART RD SE ST BOTHELL, WA 98011 STE 201 STE 201 ISSAQUAH, WA 98027 ISSAQUAH, WA 98027 (425)271-5598 (425)271-5598 (425)271-5598 LICENSE #: MOOREFP 116NP E-XP:08/26/2019 FLOW TROUGH FIRE SPRINKLER FOR NEW SFR VALUATION: $0.00 PERMIT TYPE: Residential PERMIT GROUP: 30 - Fire Sprinkler GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: OTHER: ------- OTI-IER DESC: ?_ONE: NUMBER OF STORIES: 0 1 VESTED DATE: NUMBER OF DWELLING UNITS: 0 ILOT #: EMSTING AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 'O BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS:0 BATHROOMS:O BEDROOMS:0 BATHROOMS:0 FRONTSETBACK REQUIRED: PROPOSED: RLQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEMS COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. v Signature Print Name Date Releas d By Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC 110/ IRC 110. FIRE APPLICANT = ASSESSOR CITY 9 STATUS: ISSUED BLD20171150 • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which avariance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Seances are now scheduled online. If you FIRE (425) 775-7720 3. Then: Permits/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand corner) (425) 771-0220 RECYCLING (425) 2754801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Acceptance • F-F ire Final �- o _ DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT ._t APPLICATION Fst l ggo 121 5`h Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 2 Fax 425.771.0221 PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): 22924 102nd PI. W Edmonds, WA 98020 Parcel #: 00610700100500 Subdivision/Lot #: Lot 3 Project Valuation: $ $6,750 APPLICANT: Christine Carlson Phone: —T—Fax: 425-271-5598 Address (Street, City, State, Zip): 14401 Issaquah -Hobart Rd SE # 201, Issaquah, WA 98027 E-Mail Address: christine@moorefire.com PROPERTY OWNER: Highpoint Investments LLC Phone: Fax: Address (Street, City, State, Zip): 14915 102nd Ave NE, Bothell, WA, 98011 E-Mail Address: LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Moore Fire Protection Phone: 425-271-5598 Fax: Address (Street, City, State, Zip): 14401 Issaquah Hobart Rd SE #201 Issaquah, WA 98027 E-Mail Address: *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. Date: #MOOREFP116NP FityBusiness License #/Exp. Date: DETAIL THE SCOPE OF WORK: Installation of an Automatic Fire Sprinkler system in anew residence PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: s . ft. Select Basement Type: Finished LJ Unfinished 1" Floor: s . ft. Gara e/C ort: s . ft. 2 "d Floor: s . ft. Deck/Cvrd Porch/Patio: s . ft. Bedrooms # Full-3/4 Bath # Half -Bath # Other: s . ft. Fire Sprinklers: Yes LJ No LJ I Retaining Wall: Yes Ll No Lj Grading: Cut cu. yds. Fill cu.yds. I Cut/Fill in Critical Area: Yes LJ No I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: V SG Owner ❑ Agent/Other ❑ (specify): Signature: Date: FORM A LABuilding New Folder 201000NE & x-ferred to L-Building-New driveTorm A2014.docx Updated: 1/17/2014 CITY COSY W6 001141VF AUG 232017 APMENT SERVICES CTR. CITY OF EDMONDS FIREPROTECTION Cheeks Lot 3 2016 NFPA 13D 22924102nd PI W Edmonds, WA 98020 HYDRAULIC CALCULATIONS 14401 Issaquah -Hobart Rd. Suite 201(425) 271-5598 State Contractor's License Issaquah, WA 98027 Fax: (425) 295-7188 # MOOREFP116NP �QU a 0 1 � _/rs0 111 Hydraulic Overview Job Number: Cheeks Lot 3 P. —f no."i.,n.,m• Job Job Numbef D.Or Eeplme, Cheeks Lot 3 Anthony Baldonado Job Name: Cheeks Lot 3 Ph 425-271-5598 FAX 425-295-7188 Adbesa 1 22924 - 102nd PI W SWa Ca f iWM %e Number MOOREFP116NP Adds..] Edmonds, WA 98020 ANJ Edmonds Fire Marshal Ad&...3 Job sll ftAd" Cheeks Lot 3 System D—Ity Ant OIAppIlra4on 0.050gpm/ft= 512.00ft2 Moll D—AV Sp r**, De Nolo S.- 4.9 K-Factor 12.96 at 7.000 0.00 C—rar Per SP&M . Numbs Of SpROMn C.kNeled 256.00ft' 2 SY.—� Dem.m srn.mr D.e.ea 42.461 26.14 Total Dement 26.14 @ 42.461 Pm.wrte Rent +27.588 (39.4%) Supplies Check Point Gauges Node Name Flow Hose Flow(gpml Static(psi) Residual(psi) Identifier Pressure(psil K-Factor(K) F ow m 11 Water Supply 1292.00 70.100 0.000 tE1M1INOTON STATE MCAT! Or cOMKissm S Ei S•ItlM1IIIIatR EYS1111EEE4 TMY V. 8051 1-CO Leve1 S Fin ection t t AOOREF GNP t V�� Do% 11 t31 ...................... ...�/ ENG 20170811 Cheeks_Lot3 DWG working Water Supply at Node 11 (1292.00, 0.00, 70.100, 0.000) 100 _.1 E i E E 90 f l 80 t 70 Static Pressure 70.100 i E 60 11 \1—L i 50 i .14 42.461 2 40 a ystem demand curve 1 20 10 0 1292.00 0. PM'0 000 1500 2000 25M 7501 1250 1750 2250 Water flow, gpm lam, © M.E.P.CAD, Inc. LM AutoSPRINK®12 02.0.61.0 8/17/2017 11:06:18AM Page 1 1111Hydraulic Summary Job Number: Cheeks Lot 3 Report Description: Residential Job Job Number Design Engineer Cheeks Lot 3 Anthony Baldonado Jab Name: Cheeks Lot 3 State CeN&atloN icensa Number MOOREFP116NP Address E 22924 - 102nd PI W AHJ Edmonds Fire Marshal Address 2 Edmonds, WA 98020 Job SltelBuYding Cheeks Lot 3 Address 3 Orewlg Name ENG 20170811_Cheeks_Lot3 DWG_working System Remote Area(s) Mod Demerd;" Sprinkler Data O_pancy Job SURx 4.9 K-Factor 12.96 at 7.000 Residential Haseak-At Source Dendty Area&Appr Ib, 0.00 0.050gpm/ft2 512.00ft2 Addlllanel Hose Suppf Number Q Spd Aders Gel leted Coverage Per Svk m Node Flow m 2 256.00ft2 AutoPeak Resubs: Pr re For Remote Ares(s)Ad)aunt To Most Remote Area T.W Haee Streams :( r.yYr.�E�,^.��r,,•,�� 0.00 .� y ut: .y_� 11, Sydem Flow Demand ed + • tt tJ` n•g { .jtf: • Totel W9tersWgWr�d4lip�utllnp,HonErfJlowance) Y 26.14 A 26.14 Meximam Preswre Unbela Loops ' ` 0.000 ? [Vti;. n'E r g Maximum VebcXyA . G41W. 10.79 between rVbdes 7 and 6 Maximum Vebdty UMer Greuallysu,.n ..:A 10.79 between odes'11'ah-00, Volume capacityof Wet Pipes �t. Jw� Vdume apdty of Dry pW A...-....- it 23.66ga1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin oc oe Node Name m (psi) psi) m si m (psi)(psi) 11 Water Su ply 70.100 0.000 1292.00 70.048 26.14 42.461 27.588 Contractor C. dor Number Moore Fire Pro Cortad Name Tracy V. Moore Goofed Title President Nome of Contredor: Moore Fire Protection Phone 425-271-5598 Exlemion Address I 14401 Issaquah -Hobart RD SE, Suite 201 FAX 425-295-7188 Address 2 Issaquah, WA 98027 Email tracyvmoore@gmail.com Address 3 W.bSite http://moorefire.com/ & @ M.E.P.CAD, Inc. 11 AutoSPRINK®12 02.0.61.0 8/17/2017 11:06:21AM Page 2 111 Hydraulic Graph Job Number: Cheeks Lot 3 Water Supply at Node 11 100 so 80 70 Static Pressure 70.100 60 50 Tn U) 42 a 14 42.461 40 30 Svstern demand curve 20 10 0 1292.00 0.000 0250 500 750 1000 1250 15M 1750 20� 2250 2500 Water flow, gpm Hy@sort Graph Water Supply at Node 11 static: Pressuro 70.100 Ra,4,1 1: Pressure 0.000 @ 1292.00 Ayailabk Pressure at Time of Test 70.048 @ 26.14 sy— oemmm 42.461 @ 26.14 swaa oem.ea Oamarg Ra.aAaaaree � sauce? 42.461 @ 26.14 & @ M.E.P.CAD, Inc. M AutoSPRINK®12 02.0.61.0 8/17/2017 11:06:22AM Page 3 �IljqSummary Of Outflowing Devices I Job Number: Cheeks Lot 3 & © M.E.P.CAD, Inc. f' l AutoSPRINM 12 02.0.61.0 8/17/2017 11:06:24AM Page 4 1111 Node Analysis Job Number: Cheeks Lot 3 Rennrt nasrrintinn• RnsidpntiA Node Elevation Foot Fittin s Pressure si Discharge m 11 2'-8'% S 42.461 26.14 101 18'-1 S r -7.000 7.000 12.96 102 18'-1 S r -7.234 7.234 13.18 1 18'-7 T 5'-0 , Tr 1'-0 7.805 2 9'-6 T 5'-0 , Tr 1'-0 13.382 3 9'-6 T 5'-0 17.559 4 4'-2%: T 3'-0 , f -0.000 , Tr 1'-0 20.561 5 3'-0% 21.426 6 V-11% BFP -5.244 27.297 7 V-0 T 2'-0 , Tr 0'-6 27.966 8 0'-6 GloV -0.000 28.195 9 -3'-0 E 9'-0 29.940 10 -2'-0 34.686 12 18'-7 T 5'-0 7.627 (,/_�j, © M.E.P.CAD, Inc. fil AutoSPRINK® 12 02.0.61.0 8/17/2017 11:06:25AM Page 5 IHydraulic N I Analysis D Job Number: Cheeks Lot 3 Report Description: Residential Pipe Tye Diameter Flow Velocity HWC Friction Loss ILength Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Len th Summary a•••••Route 1 -DR 1.1010 12.96 4.37 150 0.030510 20'-6 Pf 1.022 101 1 18'-1 18'-7 12.96 4.9 7.000 7.805 Sprinkler, E 7'-0 , Tr 1'-0 , T 5'-0 13'-0 33'-6 Pe Pv -0.217 BL 1.1010 17.68 5.96 150 0.054170 15'-3 Pf 1.639 1 2 18'-7 9'-6 4.72 7.805 13.382 Flow (q) from Route 2 3T 5'-0 16-0 30'-3 Pe Pv 3.938 BL 1.1010 26.14 8.81 150 0.111679 24'-5 Pf 4.177 2 3 9'-6 9'-6 8.46 13.382 17.559 Flow (q) from Route 3 E 7'-0 , Tr(V-0), T 5'-0 13'-0 37'-5 Pe Pv FR 1.1010 26.14 8.81 150 0.111679 5'-3'/ Pf 0.704 3 4 9'-6 4'-2'/z 17.559 20.561 f -0.000 , Tr 1'-0 V-0 6'-3Yz Pe Pv 2.299 BL 1.1010 26.14 8.81 150 0.111679 V-2 Pf 0.355 4 5 4'-2% 3'-0%: 20.561 21.426 2Tr 1'-0 2'-0 3'-2 Pe Pv 0.510 FR 1.1370 26.14 8.26 120 0.144279 V-1 Pf 5.401 5 6 3'-0'/ 1'-11Yn 21.426 27.297 BFP -5.244 V-1 Pe Pv 0.470 FR 0,9950 26.14 10.79 150 0.182842 0'-11 Pf 0.263 6 7 1'-11'/z 11-0 27.297 27.966 Tr O'-6 0'-6 V-5 Pe Pv 0.406 FR 1.5050 26.14 4.71 150 0.024371 0'-6 Pf 0.012 7 8 1'-0 0'-6 27.966 28.195 GloV -0.000 0' 6 Pe Pv 0.217 FR 1.5980 26.14 4.18 150 0.018199 3'-6 Pf 0.227 8 9 0'-6 4-0 28.195 29.940 E 9'-0 9'-0 12'-6 Pe Pv 1.517 UG 1.2630 26.14 6.69 150 0.057232 82'-6 Pf 5.180 9 10 -3'-0 -2'-0 29.940 34.686 2E 4'-0 8'-0 90'-6 Pe Pv -0.434 UG 0.9950 26.14 10.79 150 0.182842 23'-8 Pf 7.468 10 11 -2'-0 -2'-8Yz 34.686 42.461 3E(2'-O), WMV(-1.861), 2U(0'-6), S 7'-0 30'-8 Pe Pv 0.307 0.00 Hose Allowance At Source 11 26.14 sat • • Route 2 DR 1.1010 13.18 4.44 150 0.031451 7'-5 Pf 0.611 102 12 18'-1 18'-7 13.18 4.9 7.234 7.627 Sprinkler, E 7'-0 , T 5'-0 12'-0 19'-5 Pe Pv -0.217 BL 1.1010 4.72 1.59 150 0.004700 23'-10 Pf 0.178 12 1 18'-7 18'-7 7.627 7.805 T(5'-0) 2Tr 1'-0 , E 7'-0 14'-0 37'-10 Pe Pv w•••••Route 3••••• BL 1.1010 8.46 2.85 150 0.013857 85'-1'/2 Pf 1.817 12 2, 18'-7 9'-6 7.627 13.382 8Tr(1'-0), 6T(5'-0), E(7'-0), c I 1'-0 46'-0 13VAY2 Pe Pv 3.938 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 4.67 ) = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 © M.E.P.CAD, Inc. jfiAutoSPRINK®12 v12.0.61.0 8/17/2017 11:06:27AM Page 6 �@R lHydraulic Analysis I Job Number: Cheeks Lot 3 u®Eaas� Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Elevation Discharge K-Factor Pt Pn Fittings Eq. Length �Pres..rreDownstream Summa Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm -Over Diameter Inch ALV Alarm Valve SL Branch Line Elevation Foot AngV Angie Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Bacdlow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen -Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90° Elbow UG Underground pv Velocity pressure at a point in a pipe EE 45" Elbow Eel 11'/: Elbow Ee2 22Yz° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90" FireLoc k(fM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FlreLoc k(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. G] AutoSPRINKO 12 vl2.0.61.0 8/17/2017 11:06:27AM Page 7 Cheeks Lot 3 MATERIAL SPECIFICATIONS tq a Fire Protection Products Worldwide www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are decorative, fast response, fusible solder sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover p►ate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: • wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Pro- tective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non -water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. NOTICE The Series LFII Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODY (1/2" NPT) CAP - SADDLE �- SUPPORT CUP WITH ROLL FORMED THREADS GUIDE I PIN j GUIDE PIN HOUSING / DEFLECTOR THREADINTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER I \ SOLDER LINK i i I ELEMENT _ _ _ _ DEFLECTOR (OPERATED -- - POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY RETAINER WITH THREAD -- DIMPLES SOLDER' COVER PLATE/RETAINER TAB ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) 2-1/2" DIA. (63,5 mm) 1/2" (12,7 mm) FACE OF 1/2" THREADED SPRINKLER NPT A ADJUSTMENT FITTING COVER- SPRINKLER - RETAINER SUPPORT CUP ASSEMBLY ASSEMBLY 1-7/8"t1/4" (47,6 mm t6,4 mm) ml MOUNTING SURFACE EJECTION SPRING COVER PLATE WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH SPRINKLER - SUPPORT Ot IP ASSEMBI OPERATE SPRINKLI COVER PLATE RETAINE L 7/8" (22,2 r 1-1/8" (28,6 T 3-3/16" DIA. / DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only Listed with the Series LFII Con- cealed Cover Plates having a factory -ap- plied finish. Cover Plates can be ordered by following the instructions in the Ordering Procedure section. Maximum Working Pressure 175 psi (12,1 bar) Discharge C fficient K=4.9 gpm/psis (70,6 Ipm/bars/2) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Body ......................... Brass Cap ......................... Bronze Saddle ....................... Brass Sealing Assembly....... Beryllium Nickel w/TEFLON Soldered Link Halves............ Nickel Lever ........................ Bronze Compression Screw ............. Brass Deflector ...................Copper or Brass Guide Pin Housing ............. Bronze Guide Pins ............. Stainless Steel or Bronze Support Cup ...................Steel Cover Plate .................. Copper Retainer ...................... Brass Cover Plate Ejection Spring.......... Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprinkler to activate and flow water. Design Criteria TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2613 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • the flow rates given in Tables A and B as a function of temperature rat- ing and the maximum allowable cov- erage area • a minimum discharge of 0.1 gpm/ft.2 over the design area comprised of the four (4) most hydraulically demanding sprinklers for actual coverage areas protected by the four (4) sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. TFP442 Page 3 of 6 Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure 2.3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area 160°F (71°C) Minimum Ft. x Ft. Ft. (m) Deflector to Installation Spacing Flow Pressure (m x m) Ceiling Type Ft. gpm Psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0 (4,9 x 4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in (2,4) 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm (Ipm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 gpmHt.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flowand Residual Pressure 2.3 Maximum Coverage Maximum S Ordinary Temp. Rating Area' pacing 160,F (71-C) Minimum Ft. x Ft. Ft. Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 15 9.4 (4,9 x 4,9) (4,9) (56,8) (0,65) 13R, or 13. Installed in (2,4) 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm (Ipm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.' over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Installation TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lbs.-ft. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate / Retainer Assembly by under - or over -tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler / Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet. drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non -factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. TFP442 Page 5 of 6 Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprinkler, P/N (specify): Ivory (RAL1015) ........... P/N 56-202-0-135 Beige (RAL1001)........... P/N 56-202-2-135 Pure White " (RAL9010) ..... P/N 56-202-3-135 Signal White " (RAL9003)... P/N 56-202-4-135 Grey White (RAL9002) ...... P/N 56-202-5-135 Brown (RAL8028).......... P/N 56-202-6-135 Black (RAL9005) .......... P/N 56-202-7-135 Brushed Brass............ P/N 56-202-8-135 Brushed Chrome .......... P/N 56-202-9-135 Custom Paint ............. P/N 56-202-X-135 Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tg/Cv TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqCU Fire &Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster 11 CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco® CPVC Pipe and Fittings pro- duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively for use in wet pipe automatic fire sprin- kler systems. The Tyco CPVC Pipe and Fittings are produced from Blaze - Master® CPVC compound that is a specially developed thermoplastic compound composed of post chlorin- ated polyvinyl chloride (CPVC) resin and state of the art additives. Tyco CPVC Pipe and Fittings are easier to install than traditional steel pipe sys- tems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to me- tallic piping. All female pipe thread adapters have brass inserts for dura- bility. Grooved adapters connect di- rectly to grooved end valves and me- tallic pipe, with flexible grooved end couplings. NOTICE Tyco® CPVC Pipe and Fittings pro- duced with BlazeMaster® CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards ofanyauthorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, C-UL, NSF, LPCB, MEA, and the City of Los Angeles. (Refer to In- stallation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material • Pipe: ASTM F442, SDR 13.5 • Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange Aff rapid response HOME FIRE SPRINKLER SYSTEM BlazeMaster® is a registered trademark of The Lubrizol Corporation Page 1 of 2 J U N E, 2008 TFP1915 Page 2 of 2 TFP1915 Installation Tyco® CPVC Pipe and Fittings pro- duced by Tyco Fire & Building Prod- ucts (TFBP) are to be installed in accordance with Installation Hand- book IH-1900 dated June 2008. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- ance with local requirements and/or national codes. NOTICE Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. 0 2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 he GG/B /C� stem Compati a Progra r t DD�t3DQGlfl 2. a (1 FLOwGI r Ii.OW PIPE& R7M? NOT A DROP OF DOUBT. www.flowguardgold.com (FCG ,"-BM=CZ SYSTEM COMPATIBLE Eliminate Questions About ! Chemical Compatibility y The FGGBM/CZ" System Compatible Program is designed to test and monitor ancillary products on an ongoing basis to ensure chemical compatibility with -�' FlowGuard Gold® and Corzan® water distribution systems and BlazeMaster® fire sprinkler systems, Over the last 50 i years, billions of feet of FlowGuard Gold®, Corzan® and ` BlazeMaster® pipe have been successfully installed in millions of homes, condominiums, apartments, hotels and • i high-rise buildings around the world without incident. Occasionally there have been instances where our piping systems were damaged when coming in contact with incompatible ancillary products such as thread sealants, leak detectors, firestops, etc. Thanks to this exclusive Program, installers can simply check the label for the new FGG/BM/CZ"" System Compatible mark. r FIRE SPRINKLER SYSTEMS www.blazemastercom This exclusive Program confirms chemical compatibility with our CPVC products: • FlowGuard Gold® pipe & fittings • BlazeMaster® pipe & fittings • Corzan® pipe & fittings Products are continually being added to the FGGBM/CZ' System Compatible program. Refer to www.flowguardgoid.com, www.blazemaster.com or www.corzancpvc.com for the most current list of compatible products. LEGAL DISCLAIMER: The FGG/BM/CrSystem Compatible Program only applies to RowGuard Gold*, BlazeMaster', Corzan• and BeafthGuard" CPVC.Other manufacturers and/or brands of CPVC piping products are not eligible and do not comply with this Program. CPVC products are made from compounds which may contain CPVC resins that have different molecular weights and different chlorine content and these factors can Impact the performance of the resulting products. Addibonatly, CPVC compounds contain performance addbes that affect the performance characteristics of the ancillary product. Thus, the FGGBWCZ System compatible program is only applicable to assess the chemical compat tility of products and materials with Lubrizol's FlowGuard Gold, BlazeMaster, Conan, and HeafthGuard CPVC and bears no liability for any failures that may occur l the products on the FGGIBM/CZ System Compatible Program are used with CPVC products other than FlowGuard Gold, BlazeMaster, Corzan and HealthGuard. cl PIPING SYSTEMS www.corzancpvc.com The FGG/BM/CZT°" System Compatible Products The following products meet the standards and are deemed to be System Compatible: Antimicrobial Coated Steel Fire Sprinkler Piping (Factory Applied) Wheatland llrbe Companys MIC SHIELD'"' Coating-.... www.wheatiand.com ('For steel pipe manufactured after 2122109, Antimicrobial Coating for Steel Fire Sprinkler Piping (After Market) Potter Pipe-ShieldT"".......................................................www.MIC-Test.com Cutting Oil Ace Transul-Kut 3200 Cutting Oil..................................www.lube-tech.com CL-Free PLUS Thread Oil............................................www.achemists.com FPPI - ThreadFit° Cutting Oil.....................................................www.fppi.com Lubsoil Lubscut 3462 Lite Oil...............................................www.tulco.com Ridgid' Fneura-Cleal-T"'........................................................www.ridgid.com Turf -Cut Clear Thread Cutting Oil.........................................www.tulco.com Whitlam Thread -Cut Plus.............................................www.jcwhitiam.com Leak Detectors megabubble ' Leak Detector........................................www.herchem.com Rectot-SealT"" Better Bubble'''.....................................www.rectorseal.com Firestop Sealants A/D FIREBARRIER Intumescent Sealant............................www.adfire.com A/D FIREBARRIER Silicone' (red & gray)............................www.adfire.com A/D FIREBARRIER Silicone SL' (red & gray)........................www.adfire.com BioStop` 350i & 500+............................................www.biofireshield.com BioStopr BP 150......................................................www.biofireshield.com BlazeMasler" Caulk & Walk.....................................www.blazemaster.com Hilti`' CP 601 S Elastic Firestop Sealant'..........................www.us.hilti.com Hilti CP 604 Self -Leveling Firestop Sealant'.......................www.us.hilti.com Hilti" FS-One.....................................................................www.us.hilti.com Metacaulk' 350i & 1000..............................................www.rectorseal.com Metacaulk" MC 150+..............................................www.rectorseal.com STI PENSIL" 300.........................................................www.stifirestop.com STI SpecSeal=' LCI Intumescent Firestop Sealant .........www.stifirestop.com STI SpecSeal" Series SIL300......................................www.stifirestop.com STI WF300 Firestop Caulk.........................................www.stifirestop.com Tremco Pyre-Caulk.............................................www.tremcofirestop.com TREMstopT"I Fyre-Sil..........................................www.tremcofirestop.com TREMstopT" Fyre-Sil SL....................................www.tremcofirestop.com TREMstopT"' IA.................................................www.tremcofirestop.com TREMstopT"' IA+................................................www.tremcofirestop.com 3M Fire Barrier Water Tight Sealant 1000 NIS' ............www.3m.com/firestop 3M Fire Barrier Water Tight Sealant 1003 SI-' ............www.3m.com/firestop 3M IC 15 WB+ Firestop............................................www.3m.com/firestop 3M 3000 WT Firestop.............................................www.3m.com/firestop /'Silicone based Firestop) Firestop Wraps BioStopT'•' Wrap Strip............................................www.biofireshield.com Hilo`-CP 648-S / CP 648-E.................................................www.us.hilti.com Metacaulk" Wrap Strip................................................www.rectorseal.com Firestop Cast -In Devices Bio Fireshied1m Cast -In -Place Firestop Device .......www.biofireshield.com Hilti' 'CP 680-N / CP 680-P.................................................www.us.hilti.com Hiltil Top Seal Plug.............................................................www.us.hilti.com Hiltil Water Barrier Module.................................................www.us.hilti.com IVletacaulk'" Cast -In -Place Firestop Device..................www.rectorseal.com Presealed Systems° Hydro Flame...............www.presealedsystems.com Presealed Systems HydroPreseal...............www.presealedsystems.com ProSet Systems White ProSeal Plug....................www.prosetsystems.com STI SpecSeal Cast -In Firestop Device..........................www.stifirestop.com Firestop Collars BiostopT"I Pipe Collar............................................www.biofireshield.com Hilti" CP 643N..................................................................www.us.hilti.com Ivletacaulk" Pipe Collar...............................................www.rectorseal.com Termiticide / Insecticide Bora-Care'.................................................................www.nisuscorp.com Thread Sealants Anti -Seize lechnology Sllckon'"' GTS Gold-" ................www.antiseize.com Black Swan's Big White Pipe Joint Compound .....www.blackswanmfg.com FPPI° PipeFO......................................................................www.fppi.com IPS' Blue Seal...................................................................www.ipscorp.com IPS" White Seal Plus..........................................................www.ipscorp.com Jet-Lube' TFWT"^..........................................................www.jetlube.com LA -CO"' Leak -Titer Blue.........................................................www.laco.com LA -CO` Slic-Tile" Paste.......................................................www.laco.com Lyrical ProSeal Plus............................................................www.lyncar.com Oatey` Great White'.............................................................www.oatey.com Permabond" LHO56.................................................www.permabond.com pro dope"' Thread Sealant.........................................www.herchem.com RectorSealI"' T Plus 2.................................................www.rectorseal.com Whitlam Power Seal Plus.............................................www.jcwhitiam.com Freeze Protection FireFightel"GL - Ready-To-Use'............................www.noblecompany.com FSS ProTect GL - Pre-Mix'.....................................www.huguenotiabs.com ("Gly(,erin for fire sprinklers) Insulation* ArcticFlex'"...............................................www.nomacoinsulation.com Econotherm=..............................................www.nomacoinsulation.com Ecoshielrh'.................................................www.nomacoinsulation.com Frost King.....................................................www.nomacoinsulation.com Imcol-ock'.....................................................www.nomacoinsulation.com Imcoshield"..............................................www.nomacoinsulation.com Nomagar&..................................................www.nomacoinsulation.com Nomalock"...............................................www.nomacoinsulation.com lherma-cel')...................................................www.nomacoinsulation.com Tundra......................................................................www.tundrafoam.com Tundra Plus..............................................................www.tundrafoam.com Tundra Seal..............................................................www.tundrafoam.com (Insulation products listed are made of polvolefin) Seismic / Expansion Devices Loos & Co. - Seismic Wire Rope/ CableTm Bracing ................................... www.earthquakebrace.com Metraflex"Fireloop" Expansion Joint for Fire Sprinkler Systems ...................................... www.fireloop.info System Accessories FlexIdead" Fire Sprinkler Connections...........................www.flexhead.com Sioux Chief CPVC llarsition Fittings..........................www.siouxchief.com Gasket & Gasket Lubricant FPPP LubeFiF Gasket Lubricant............................................www.fppi.com Garlock- Stress Saver' XP Gasket....................................www.garlock.com LA -CO` Lubli-Joint"; Water Dispersible Gasket Lubricant ........www.laco.com Phoenix'' 27-A Water Dispersible Pipe ,Joint Lubricant...........................................www.itmproductsinc.net Whitlam Quick Slip Plus..................................................www.joinpipe.com Detergents Alconox"..............................................................www.alconox.com LEGAL DISCLAIMER: The FGG/BM/CP` System Compatible Program only applies to FlowGuard Gold', BlazeMastW, Corzan° and HealthGuard'" CPVC. Other manufacturers and/or brands of CPVC piping products are not eligible and do not comply with this Program. CPVC products are made from compounds which may contain CPVC resins that have different molecular weights and different chlorine content and these factors can impact the performance of the resulting products. Addwnall;, G°Vl, co.11ro I ms rrq(•+r Onorl olre addinres [hat ahnc'. We pedo^nancr. of J N an th" pnduct. Thus, tha S}s'em .,o -pa'ibl oingr:m is.9nly arp6nanle to aster iha Lhei' r amd , t and r .lerinls ,,,it I m ol s Flox6ua :. Golaoen. ain HeallhGaaio G"Vs aid bears no Ilaod ly'or anv [a lures ;a;t n a, ac:u I the p,:dbc's on :he F�al/BtJV System Lomoat bte Prcmam ae usao ue- C"VC oiaducis otnei nai FI_nuuam wid Bate .L:=1e , Lc/an and HealtaGuaid v P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - eE" 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL a Eas FASTENERS PER NFPA 13 - See table. term FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. aE- MOUNTING FASTENERS Pipe Wood Steel- Mia. to GA. CPVC #905 or #IO xl SMS #14 or 1/4 Tek Copper #905 or #10 xl SMS #14 or 1/4 Tek SMS = Sheet Metal Screw Tek—Tek Screw AFCON#905 screw - custom 5/16" hex head. Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or Profit, when non AFCON products have been. or are used. 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET HANGER & RESTRAINER CPVC - COPPER - STEEL SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil: Galvanized. LISTING/APPROVAL - "ul ts. 203 - EX 4231, EX 2551 ze 3/4 -1 1/4: Fastener )acing fits on wood 2 x 4 Installation - Backing Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastene PATENT - No. 6,648,278. FUNCTION - Hanger for support of CPVC or copper pipe. Hanger for steel pipe at 15' spacing per NFPA 13. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. Hanger/ INSTALLATION - Per these instructions Restraine including NFPA 13, 13R, 13D and CPVC manufacturers. Snap over pipe then squeeze strap back allowing pipe to slide freely. When fastener threads are exposed through wood, install backing nut - See drawing. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL c@as FASTENERS PER NFPA 13 - See table. uarra FEATURES * 1 1/211 Offset * Common center -line for 3/4" and 1". * Offset edge eliminates abrasion. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. °Oa- MOUNTING FASTENERS Pipe Wood Wood - Thru 5i8- Gyp Steel - Min.18 GA. CPVC #905 or #10 x1 SMS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 x] 1/2 SMS or 1/4 xl 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS - Shect Metal Screw Ls — Lag Scrcw Gyp= Gypsum Board Tek=Tek Screw AFCON #905 screw - custom 5/16" hex head. Hanger/Restrainer Hanger/Restrainer bilize Specific AFCONproducts are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured m sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER/RESTRAINER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - °(E)at 203 - EX 4231, EX 2551 UMD ALTERNATIVE FOR #500 Pipe Strap 510 Fastener SIZE Dim. (I-Q 3/4 2.125 1 2.312 1 114 3.170 1 1/2 3.400 4.010 2 1/2 4.320 3 1 5.320 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Hanger for steel pipe at 15' spacing per NFPA 13. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL @a: FASTENERS PER NFPA 13 - See table. LIM FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. Han; r©- MOUNTING FASTENERS Pipe Wood Wood — Th. 5/e- cyp Steel - Mln. to CA. CPVC #905 or #10 xi SMS #14 x 1 1/2 SMS or 1/4 x 2 LS #14or1/4Tek Steel/Copper #14 xl 1/2 SMS or 1/4 xl 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS - Sheet Metal sercw LS = Lag Screw Td--T& S Board AFCON #905 screw - custom 5/16" hex head. Tek=Tek Scrcw Restraint Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCONproducts have been, or are used. ibilize 1/16 Model DC4A & DCLF4A DOUBLE CHECK VALVES JA Mi. �� valve STANDARD OR LEAD FREE* Job Name: Contractor: Job Location: P.O. Number: Engineer: Representative: Tag: Wholesale Distributor: DESCRIPTION The Apollo® Model DC4A Double Check Valves and DCLF4A Lead Free* Double Check Valves prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are objectionable to the potable water supply, but non -health hazards. The top accessed modular check valve cartridges provide captured springs, replaceable seats and reversible silicone seat discs. This Made in America assembly features Apollo® ball valves with stainless steel handles and nuts as standard and carries the five-year Apollo® factory warranty. FEATURES • Low pressure loss documented by independent approval agencies • Easily removable modular check valve cartridge • Captured stainless steel springs • Apollo® ball valves w/ SS handles & nuts standard • Top -mounted test cocks for easy testing • No special tools required • Chloramine-resistant elastomers • Designed, cast, machined, assembled and tested IN THE USA OR[ 4AX �N INFORMATION —XXFXX OPTIONS (Blank) - Standard SS Handle ❑ LR - Locking Round (1/2"— 1 ") ❑ LL - Locking Lever (1 '/4" — 2") (Blank) - NPT Testcock (NA for LF* %" — 1 ") ❑ F - SAE Testcock (NA for LF* 1 '/," — 2") ❑ T1 - Less ball valves ❑ T2 - With ball valves (Standard) ❑ T4 - With union -end ball valves SIZE ❑3—'/2" ❑5-1" ❑7-1'/2" ❑4—%" ❑6-1'/:' ❑8-2" Y-STRAINER ❑ 0 — None (Standard) ❑ 1 — With Y-Strainer MATERIAL (Blank) - Standard material ❑ LF - Lead Free' APPROVALS ASSE 1015 - Horizontal and Vertical Flow Up ('/2'-2") CSA 13.64.5 - Horizontal and Vertical Flow Up ('/2"-2") k4+ PERFORMANCE RATING fit— ISO 9001:2008 Maximum Working Pressure 175 psi REGISTERED Temperature Range 33 * F —180 * F iN usP - zzq �rf fL i hr - DIMENSIONS (in.) /"'VI B A -- -- Ordering No. Size A B C D Wt. 4A103T2 '/2" 11 7 % 3'/4 2'/2 4.4 4A104T2 %11 12 % 8 % 3 % 3 6.0 4A105T2 1" 14 % 9'/2 4 3'/4 10.0 4A106T2 1 Y4" 18 % 11 % 4 Y2 4 % 14.0 4A107T2 1 Y2" 18 % 11 % 4 % 4 % 1 17.0 4A108T2 2" 21 % 12 % 5 5 % 25.4 MATERIAL SPECIFICATIONS Part Name Material Body, Caps, Ball Valve Shutoffs, Test cocks Bronze C84400 or C89836 (Lead Free' Check Valve Cartridges Glass -Filled PPO Springs 300 Series Stainless Steel Seat Discs Chloramine-resistant Silicone 0-rings Chloramine-resistant EPDM " Lead Free per section 116875 of the California Health & Safety Code Conbraco Industries, Inc. 701 Matthews Mint Hill Rd. Matthews NC 28105 USA; www.apollovalves.com; 704-841-6000 This specification is provided for reference only. Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. SS1034 ©4/10 Page 1 of 2 Model DC4A & DCLF4A DOUBLE CHECK VALVES to OVA STANDARD OR LEAD FREE* �. ... FLOW CURVES, Curves developed from independent approval agencies actual tests — Consult factory for details. ■ indicates rated flow as determined by approval agencies, 7.5 ft/sec is the typical maximum Plumbing system flow rate. DC4A 7.5 fps 1/2" pipe 7.5 fps 3/4" pipe ■ indicates rated flow 12 11 IL 10 y 9 O 8 J 7 W � 6 rn 5 W � 4 a 3 2 0 5 10 15 20 25 30 35 40 RATE OF FLOW (GPM) 000 3/4" 1/2", � i DC4A 7.5 fps 1" pipe 7.5 fps 1 1/4" pipe ■ indicates rated flow 12 11 a 10 rn 9 0) 8 O J 7 W � 6 N 5 w 4 a 3 2 0 10 20 30 40 50 60 70 80 90 100 RATE OF FLOW (GPM) 12 11 a 10 � 9 N 8 O J 7 W Q' 6 N 5 w 4 IL 3 2 , , DC4A inrliro}nc r�}n.l anu. i.5 tps i vz- pipe i.a ips r pipe 1 1/2" i 2" 0 20 40 60 80 100 120 140 160 180 RATE OF FLOW (GPM) * Lead Free per section 116875 of the California Health & Safety Code Conbraco Industries, Inc. 701 Matthews Mint Hill Rd. Matthews NC 28105 USA; www.aoollovalves.com; 704-841-6000 This specification is provided for reference only. Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. SS1034 ©4/10 Page 2 of 2 (DPOTTER The Symbol of Protection The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard® CPVC pipe and Spears& CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/ test valve. The VSR-SG flow switch is equipped with union connection to facilitate the installation and removal of the switch in confined spaces. Installation 1. Using appropriate fittings connect the main water supply to the bottom of the riser and the drain connection to an adecquate drain location capable of handling the drain discharge. The riser can be mounted in the horizontal or vertical position. Direction offlow is indicated in Fig. 1. The waterflow switch must be located on the top or on the side of the pipe when installed in the horizontal position. This will prevent debris from entering the throat of the waterflow switch which could interfere with proper operation. The V NPT adaptor coupling is shipped loose and may be used to case installation. 2. Following CPVC manufacturer's instructions for preparation and gluing of CPVC piping systems, glue the main riser to the main supply line for the sprinkler heads. Note: All glued connections must be completed and cured before the flowswitch is installed. Threaded Connections A thread sealant shall be used in making threaded connections. Teflon® thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC. For other types of thread sealants, which have been specifically investigated and confirmed to be "System Compatible", refer to www. spearsmfg.com. Attach gauge to riser. Apply Teflon® tape to male fitting of gauge only. See Fig 1. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) Install the flow switch to the RD 13 Riser. Verify that the o-ring is properly positioned in its groove. Hand tighten the nut to the union after orienting RD13 RISER UL, CUL, CSFM listed, and CE Marked Service Pressure: 175 PSI (12,07 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 MPS) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250V AC 2.0 Amps at 30V DC Resistive 10 in Amps min. at 24V DC Conduit Entrances: Two knockouts provided for 1/2" conduit. Environmental Specifications: Temperature range: 40°F - 120°F (4.5°C - 49°C) - UL Replacement VSR-SG: Stock number 1144460 Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 British Standard BS9251 Optional: Cover Tamper Switch Kit, stock number 0090148 Replaceable Components: Retard/Switch Assembly, stock number 1029030 Gauge and flow switch shipped loose in box. Models: V RD13 Riser PN 1119067 1 1/4" RD13 Riser PN H19077 1 1/2" RD13 Riser PN 1119087 2" RD13 Riser PN 1119097 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. the flow switch in the appropriate direction to detect waterflow. The paddle must not rub the inside of the Tee or bind in any way. The stem should move freely when operated by hand. See Fig. 1. Note: Do not leave switch cover off for an extended period of time. Orientation 6. Side of flow switch must be perpendicular with the riser piping. See Fig. 3. Inspection and Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system, should be in accordance with applicable .Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) If provided, the inspector's test valve (usually located at the end of the most remote branch line) should be used for test purposes. If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the V drain line valve, or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve. The drain valve can be used to test the operation of the VSR-SG switch. A minimum flow of 10 GPM (38 LPM) is required to activate this switch. An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Maintenance CAUTI/� UT� O The VSR-SG waterflow switch should provide years of trouble -free ON service. The retard and switch assembly are easily field replaceable. In the Do not over -tighten the union nut, hand tighten only. Use of a wrench may unlikely event that either component does not perform properly, please order cause damage to the union nut. replacement retard switch assembly stock number 1029030. There is no maintenance required, only periodic testing and inspection. PotterElectric Signal Company, LLC • St. Louis, MO • Cust Service: 866-572-3005 • Tech Support: 866-956-0988 • Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401152 - REV J PAGE 1 OF 2 02/12 (E)POTTER ® The Symbol of Protection RD13 RISER Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced • Turn off electrical power to the detector, then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Fig. 1 OPTIONALCOVER Retard Adjustment TAMPER SWITCH The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the DO NOT LEAVE COVER minimum required to prevent false alarms. RETARD OFF FOR EXTENDED ADJUSTING PERIOD OF TIME KNOB--�� DIRECTION OF WATERFLOW A \ � \ ]"MALE FITTW O ON ALL SIZES-1 O 0 RISER MAY BE 1". 1 114", DWG. �11063-3 1 12", OR 2" Important: The paddles have raised lettering that show the pipe size and the TEE they are to be used with. The proper paddle must be used. DIRmanufacturer WATERFILFLOW OF E The paddle must be properly attached and the screw that holds the paddle must be securely tightened. Fig. 2 Dimensions *(See Chart Below) 1T VSR-SG FLOW SWITCH I NPT ADAPTER GAUGE I"NPT DRAIN VALVE - I"NPT COUPLING (SHIPPED LOOSE) DWG# 1152-2 Fig. 3 Orientation DWG# 1152-3 Plow switch must be properly orientated. Side of cover must be perpendicular with the pipe. Improper orientation could delay or prevent *RD13 Risers (ASSEMBLED DIMENSIONS) Riser Size Model Number Part Number Dimension "A" Dimension 'B" Dimension "C" Dimension "D" (in) (MM) (in) (mnl.) (in.) (n:m) (in) (mm.) 1" RD13-100-1 1119067 16 406 15 3/4 400 12 1/4 311 10 1/2 267 1 1/4" RD13-125-1 1119077 16 5/8 422 16 1/2 419 12 1/2 318 10 5/8 270 1 1/2" RD13-150-1 1119087 N/A N/A 16 3/4 425 12 3/4 324 10 3/4 273 2" RD13-200-1 1119097 1 N/A I N/A r 18 1/4 1 464 1 13 3/8 1 340 1 11 1/8 283 PRINTED IN USA MFG. #5401152 - REV J PAGE 2 OF 2 02/12 (E)POTTER The Symbol of Protection These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. BELLS PBA-AC & MBA -DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150OF (-340 to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC MBA126 1750070 .12A 85 76 8 (200) 12VDC MBA128 1750080 .12A 90 77 10 (250) 12VDC MBA1210 1750060 .12A 92 78 6 (150) 24VDC MBA246 1750100 .06A 87 77 8 (200) 24VDC MBA248 1750110 .06A 91 79 10 (250) 24VDC MBA2410 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC - 2081 Craig Road, St. Louis, MO, 63146-4161- Phone: 800-325-3936/Canada 888-882-1833 - www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y PAGE 1 OF 2 5/08 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA -DC Bells Dimensions Inches (mm) Fig. 1 10" (250) - 8 �— (200) 6„ I (150) I �� I I 2 I1/16" (68) D\VG# 776-1 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance o 5 3/4" _ 3 3/8' 5" (146) (86) (127) 3 3/8" 15/8" (86) (41) 4 1/4" (108) D\VG# 77&2 Wiring (rear view) Fig. 3 A.C. BELLS WHITE (IN) N HITE (OUT) 0 FROM CONTROL PANELOR PRECEDING BELL BLACK (IN) BLACK (OUT) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. FND-OF-LrNE RESISTOR IS NOT REQUIRED ONAC BELLS. Installation 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y PAGE 2 OF 2 5/08