Loading...
Doc0006.pdfRESUB Cit v of Edmonds AUG 18 2016 r,311.11LIDNEPARTA O SMT PLAN REVEEW COMMENTS 01-�Y OF", OWN= BUILDfNG DIVISION (425) 771-0220 DATE. August 5, 2016 4J bIG �2 T TO- Roil Johnson, Architect 46V FROM: Chuck Miller, Plans Examiner RE: Plan Che& BLD2015-1559 Protect Addres,sM '16our 404 75Place W k"ITY' COPY Project: Abbott SFR Scope: Construct single-family residence w/attached garage — R - 3/U occupancy group — V-13 construction - sprinkler system required— mechanical ,md plumbing included Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Plarming, Engineering, or Fire, may result in additional comments, that require attention beyond the scope of this letter. Items that recurr on this list appear in italics. A complete review cannot be perfortned until the revised, P111ans/documents, including a written res Manse in itemized letter format Indic tin where the.'clouded' or otherwis highlighted changes can be found on the revised plan , have been submitted to a Permit Coordinator. Resubmittals rilust be made at the Development Services Departnient on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from earn-4:30prn and froni 8:30am-12lain on Wednesdays. General Review Notes: I . Provide as part of a complete submittal structural calculations prepared and 'stamped' by an 0 .-, engineer supporting the design, of the temporary soldier pile walls represented oil sheets 'l, and '2' of tile submitted 'Grading Plan' and sheets 'At, 'AT, and 'AY of the architecturallstructural plans for the proposed structures to be constructed under this permit and permit 131.132015-1602. On the Site plan: ((' < � j s AtL '�'t a' Indicate on the plans whether the 'conc. block walls' on the north pro erty line an `ecology block wall' and the `con o k wall' alongthe south ro ert -line are existing' S, Lould`p All construction proposed as part of the scope of work under this permsed'. be referenced in the various reports/documents-required per ECDC 19.10 -and have - detailed architectural and.structural plans with structural calculations and specifications incorporating the design parameters established by the geotechnical engineer. On sheet S2 — Main Floor Framing: am Floor Framing Plan 2r Clarify on the plans the callout for the east -most (3)1-3/4x14 LVIJ to be used to support the point load below the 5-114x11-718 PSLs over the south end of the `Kitchen'. tt a b overs anned and de ects b and that ermined er.IRC Table 8301.7. The represented placement is also one foot west of that anticipated by t e work indicated on sheet `S3'. NOW ��ftloa lv SAJ a `Z 1-15:5. b Clarify on the plans the callout for detail `TYP/S6' at the three no -south interior `SW2' shear walls. An applicable detail xeflecting that anticipated by the represented construction could not be found. On sheets S3 and S4: �_�ndzcateon the plans the required, construction of shear walls to transfer lateral loads to resistive elements below when adjacent to floor openings. Typically, `balloon -framed' walls are used in areas such as those to the north and the east of the `Loft area'. The shear walls must not. exceed the maximum shear wail aspect ratios per American Forest & Paper Association `Special Design Provisions for Wind and Seismic' (AF&PA SDPWS) Table 00 T� 4.3.4. Of particular concern are the walls in the northeast corner of the structure, along wall lines `AB' and 7'. The response to the plan review comment states: "See revised plan,". No changes appear tohave been made to the resubmitted plans. On sheet S3 — Upper Floor Framing: Upper Floor Framing'Plan .,� a. Indicate on the plans the minimum required post to support the loads below`each end of the north -south oriented hip girder truss over the bedrooms. b. Clarify the note on the plans "The 3-1/2" x 11-718" PSL sits below the 5-1/2.x 11- y 718" PSL". The north -south PSL appears to have been changed on the plans and now both•beams are 5-112x11-7/8 PSI -s. On sheet S4 -- Roof Framing Plan: It 10 �a. oof Framing Plan Clarify the callout for a shear wall adjacent to the floor opening and over the door A 0 opening in the north wall of the 'Office. The response to the plan review comment Y v states: "See revised plan.". No changes appear to have been made to the ft resubmitted plans. Page 2 of 3 c ! Indicate on the plans the minimum required post to support the loads below each end of the girder truss over the stairs and `Loft Area. The `typical' 44 post appears to be undersized for the noted loads. The response to the plan review comment states: "See note added to plans.". A note does not appear to have been added to the resubmitted plans. On sheet S5 — Section Details: Section 5 — West Wall Detail _ Provide as part of a complete submittal structural calculations prepared. and `stamped' by an engineer supporting: the design of the grade beam/foundation wall. The response to the plan review comment states: "See enclosed calculations.": Tlie calculations appear to support the design of a grade beam_ different than at specified on thel;knnss.��} f' CAT&_ (41 4 On sheet S7 — Detatis: �8_ Detail 4 - Indicate on the plans the required placement of reinforcement to connect the retaining wall footing to the pile cap/leveling footing below. The response to the plan review j comment states: "See revised plans.". Nd.cbanges regarding the connection of the retaining �11V' wall footing to the pile cap/leveling footing below appear to have been made to the resubmitted plans. F C - Page 3 -of 3