Response to Planning and Engineering.pdfM Engineering Jen Machuga and Jenifer Lambert City of Edmonds Development Services Department 1215th Avenue North Edmonds, WA 98020 RE: 18310 Sunset Way (Murata SP Lot 2) Plan Check #BLD20150992 Plan Review Comment Response RAM Job No. 15-025 Ms. Machuga and Ms. Lambert: �° rr mar J �w�d,�` �� �L SUB NOW () 3,� 21115 4BU i)IPV' G iii t ��V'ri�I E ��i Cq .�. ; 6F E_,5i'INiiOi'J'DS November 3, 2015 This letter outlines the revisions and corrections made per your plan review comments dated October 13, 2015 and October 15. Below is a list of the comment response documents addressing your comments and requests: M 1, Native Vegetation Plan: When the subject site was created through the recent short plat (File No. PLN20130059), it was subject to the native vegetation requirements of Edmonds Community Development Code (ECDC) 23.90.040.C. Please respond to the following comments regarding the Native Vegetation Plan: a. Correct the location of the native vegetation area as shown on the site plan to be consistent with the location of this area on the approved native vegetation plan. Revised native vegetation areas are proposed. The native vegetation areas correspond with proposed revised areas (under separate review). Your site plan indicates that the portions of the native vegetation area that are disturbed with the subject development will be replanted per the approved plan. Please indicate the anticipated level of disturbance to the native vegetation area. Do you only anticipate disturbance within the portion to the southwest of the proposed house where the proposed grading is located, or do you anticipate disturbance elsewhere within the native vegetation area? Do you anticipate the need to remove any vegetation that had existed on the site prior to the subdivision, or only the newer plants that were planted this past spring? Limited areas are proposed to be disturbed within the native vegetation area (NVA). Some of the existing vegetation and newly planted vegetation within the NVA will need to be replanted. Clearing limits, silt fence and notes have been added to the plans indicating these areas; see Site Development Plans, Sht. 1 of 2. c. Please note that any necessary replanting of the native vegetation area will be required prior to the issuance of a certificate of occupancy for the subject residence, and an inspection by the Planning Division will be required upon completion of the replanting. An occupancy note has been added to the plans; see Site Development Plans, Sht. 1 2. Clearing Limits: Indicate the proposed clearing limits on the plans. Clearing limits have been added; see Site Development Plans, Sht. 1 of 2. 3. Trees: Please indicate all existing trees on the subject site and indicate whether they are proposed to be retained or removed. Please also indicate all existing trees located adjacent to the subject site. Tree protection measures consistent with ECDC 18.45.050.1-1 must be indicated on the project plans for all trees that are to be retained on and adjacent to the site. Existing trees on-site and adjacent to the site have been shown on the plans. No current existing trees on-site are proposed to be removed at this time. Tree protection orange filter fabric fence, clearing limits, and tree protection measure notes have been added; see Site Development Plans, Sht. 1 of 2. FUM Engineering 1653113`hAve W,Suite A108 Lynnwood WA 98037 (425)678-6960 RAMenginerringinc.com 18310 Sunset Way (Murata SP Lot 2) Page 2 c f 4 Plan Check #BLD20150992 Plan Review Comment Response RAM Job No. 15-025 Engineering Comments: DE11O PLAN 1) Add a note that the sewer will be cut acrd capped at the property line. A note has been added to demo plan (see Sht. 1 of 1). 2) Note on the plans the water being cut and capped at the meter and that an A\'B will be installed. The old existing water meter to the house has been removed per the Murata SP plans. A new 1" water meter and 1- %2" service line has been extended to the lot 2; thus no cut and cap of an existing line is needed. 1) If the demo pennit is to be issued prior to the issuance of the single family residence. a separate erosion control plan trust be submitted, reviewed and approved to be issued with the demo permit. Demo permit will not be pulled prior to the issuance of the single family residence permit; demo permit shall implement the erosion control plan measures shown on the single family residence permit plan set. ***The building permit for the single family residence cannot be issued until the proposed impervious area is consistent with the allowable impervious area as shown on the recorded short plat document.'"** Okay; a revision to the recorded short plat documents are being processed. GENEKAL 1) Please add a note to the plans that state the existing utilities will be reproved and'or capped under the demolition pennit (BLD20150991). Notes have been added to demo plan (see Sht. 1 of 1). 2) Revise the plans to be consistent with the asbuilt drawings for the short plat. A revision of the allowable impervious areas on the recorded Murata short plat documents and a revision to the native vegetation plan are being processed to match the proposed site development plan. The existing utilities shown on the site development plan are to the best of our knowledge the correct existing locations. °' 0SI `` t " )V " O 1) Show all trees on the plans. Existing trees have been added to the plans; see Sht. 1 of 2, 2) Sho\v tree protection at the drip line of the trees. Tree protection orange filter fabric fence, clearing limits, and tree protection measure notes have been added; see Sht. 1 of 2. STORM 1) Show the irivert elevations for the storm stub. Storm invert elevations have been added; see Sht. 1 of 2, 2) Show the invert elevations at the house so that we can veri6, pipe slope and coverage. Storm invert elevations at the house has been added; see Sht. 1 of 2. RAM Engineering 1653113`hAve W,Suite A108 Lynnwood WA 98037 (425)678-6960 RAMenginerringinc.com 18310 Sunset Way (Murata SP Lot 2) Plan Check #BLD20150992 Plan Review Comment Response RAM Job No. 15-025 NVATER Page 3 of 4 1) It appears that a fire sprinkler system is required for this property. Typically if there is an existing water service line from the watennain to the meter it will not be the appropriate size and a new tap will be required. a. Please show the water service line from the meter to the house. Water service line from meter to the house has been added; see Sht. 1 of 2. b. Please add a note that a 1" meter is to be installed or has been installed. Existing 1" water meter call -out added; see Sht. 1 of 2. c. Please show a 1-1/2" line to be installed or note that it has been installed (as required for a combination fire and domestic service line). Existing 1- %" water service line call -out added; see Sht. 1 of 2. d. Please label the pipe material and note tracer wire to be installed on the water service line. Water pipe with tracer wire call -out has been added, 1- %" PE (200 PSI); see Sht. 1 of 2. SEVER 1) No Continents DRI' ITTILITIES 1) No Comments If there are any questions regarding the items above or the contents of the revised drawings please contact me at your earliest convenience; I can be reached at (425)678-6960 or RobL@RAMengineeringinc.com. We sincerely appreciate your time and assistance. Thank you, Rob Long, PE Principal cc: Kayla Clark, c/o Select Homes, Inc. RAM En&neeiring 165.31 1.3`x' Ave W, Suite A108 I...ynnwood WA 98037 (4715) 678-6960 RAk4en&(,rriru4, nc.com