Specs and site plan.pdf�-, i RECEIVED TABULAR DATA SHEET APR 17 2019 LX SERIES SPLIT SYSTEM HEAT PUMPSBUILDING 14.0 SEER - R-410A -1 PHASE -1.5 THRU 5 NOMINAL TONS MODELS: TH4B18 THRU 60 PHYSICAL AND ELECTRICAL DATA MODEL TH4B1821S TH4B2421S TH4B3021S TH4B3521S I TH4B3621H TH4B4221H TH4B4822S TH4B6022S Unit Supply Voltage 208-230V, 1�, 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 12.0 15.4 18.1 20.5 19.7 25.5 30.8 31.7 Max. Overcurrent Device Amps 2 20 25 30 35 30 40 50 50 Min. Overcurrent Device Amps 3 15 20 20 25 20 30 35 35 Compressor Type Scroll Scroll Scroll Scroll Recip Recip Scroll Scroll Compressor Rated Load 9.0 11.7 13.4 15.4 14.7 19.4 23.6 24.3 Amps Locked Rotor 56.3 61.6 72.5 83.9 78.0 88.0 130.0 144.2 Crankcase Heater No No No No Yes Yes No No Factory External Discharge Muffler Yes Yes Yes Yes Yes Yes Yes Yes HS Kit Required with TXV4 No No No No Factory Installed Factory Installed No No Optional Start Kit: PN S1-2SA0674 21806 10106 10106 10106 10106 10106 Fan Diameter Inches 22 22 24 24 24 24 26 26 Rated HP 1/8 1/8 1/4 1/4 1/4 114 1/4 114 Fan Motor Rated Load Amps 0,80 0.80 1.30 1.30 1.30 1.30 1.30 1.30 Nominal RPM 1075 1075 850 850 850 850 850 850 Nominal CFM 2850 2850 2995 2995 3715 3715 4000 4100 Face Area Sq. Ft. 16.15 17.94 23.82 23.82 23.82 23.82 26.40 28.80 Coil Rows Deep 1 1 1 1 2 2 2 2 Fins / Inch 22 22 22 22 18 18 1 B 18 (Liquid Line Set OD (Field Installed) 3/8 3/8 318 3/8 3/8 318 3/8 3/8 Vapor Line Set OD (Field Installed)5 3/4 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8# Unit Charge (Lbs. - Oz.) 6 5-11 6-7 7-15 8-1 12-4 12-7 15-4 14-10 Charge Per Foot, Oz. 0.62 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 120 131 176 176 230 230 235 256 1. Rated In accordance with AHRI Standard 110-2012, utilization range "A". 2, Dual element fuses or HACR circuit breaker. Maximum allowable overcurrenl protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. Use S1-2SA067**- series kit. See Hard Start Kit Accessory Installation Manual. 5. For applications with non-standard vapor line sizes, see the "Applications & Accessories" section of this Technical Guide. 6. The Unit Charge is correct for the outdoor unit, smallest matched Indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in actual Iineset length (not the equivalent length) multiplied by the per foot value. DIMENSIONS Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A B C Liquid Vapor TH4B1821S 33-1/4 29-1/4 29-1/4 3!8 3/4 TH4B24215 36-1/4 29-1/4 29-1/4 TH4B3021S 39-1/2 35-1/4 31-3/4 TH4B3521S 39-1/2 35-1/4 31-3/4 TH4B3621H 39-1/2 35-114 31-3/4 TH4B4221H 39-112 35-1/4 31-314 718 TH4B4822S 39-1/2 38 34-1/4 TH4B6022S 42-3/4 38 34-1/4 7/8# # Adeplerfifgng must be field installed for the required 1-118' llne set. All dimensions are In Inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width Include screw heads. Johnson Controls Unitary Products 5452075-BTD-A-1117 SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit TH4B1821S TH4B2421S TH483021S TH483521S TH483621H TH484221H TH412114822S TH41216022S Required TXV 1.2 BA1 BA1 131311 or BE1 BE1 BF1 BF1 BC1 BG1 Defrost Jumper Pin Setting 2 2 2 3 3 2 4 2 Indoor Unit 3,4,S Additional Charge, oz AP18B 0 - - - - - - - AP24B 7 0 - - - - - - AP30B - 9 0 - - - - AP36B - - 0 - - - - - AP36C - - - - - - - - AP37C - - - - 8 - - - AP42C - - - - - - - - AP48(C,D) - - - - - - - - AP60(C,D) - - - - - - - - AE188 0 - - - - - - - AE24B 7- AE30B - 9 0 - - - - AE36(B,C) - - 0 0 - - - - AE42C - - 3 7 8 0 - - AE48(C,D) - - - - 8 0 0 - AE60C - - - - - 1 8 - AE60D - - - - - 2 AVC1813 0 - - - - - - - AVC248 7 0 - - - - - AVC30B - 9 0 - - - - - AVC36(B,C) - - 0 0 - - - - AVC42C - 3 7 8 0 - - AVC48(C,0I - - - 8 0 0 AVC60C - - - - - 1 8 - AVC60D - - - - - - - 2 CF/CM/CU18(A,8) 0 - - - - - - - CF/CM/GU24(A,B) 7 0 - - - - - - CF/CAA/CU30(A,B,C) - 9 - - - - - - CF/CM/CU36(A,B,C) - - 0 0 - - - - CF/CM/CU42(B,C,D) - - 3 8 - - - - CF/CM/CU46(C,D) - - - 7 8 0 0 - CF/CMiCU60(C,D) - - - - - 1 8 - CF/CM64D - - - - - - - 2 Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table. f=oU i NU ► ta: 1, For applications requiring a TXV, use S1-1TVM`•• series kit 2. A TXV kit must be used with these indoor units to obtain system performance. 3. Systems matched with furnaces or air handlers not equipped with blower -off delays may require blower Time Delay Kit Si-2FD06700224- 4 CF coils cannot be used in horizontal applications. 5. Charge adders shown above do not Indicate that coils are rated for every application Refer to Performance Data Tables for actual performance for specified system matches. Obtain certified system ratings from www.ahridirectory.org. CHARGING PROCEDURES: 1 Check the Factory Unit Charge listed on the unit data plate to verify the refrigerant charge for the outdoor unit, the smallest matched indoor unit, and the 15 feet of interconnecting lineset. 2. Verify the Indoor metering device and additional charge required for the specific matched indoor unit in the system using the above table 3. Add addltional charge for the amount of interconnecting lineset greater than 15 feet at the rate specified in the Physical and Electrical Data Table. 4. For installations requiring additional charge, weigh in refrigerant for the specific matching indoor unit and actual lineset length. 5. Once the charge adders for matched indoor unit and for Ilneset have been welghed In, vedfy the system operation against the temperatures and pressures In the Charging Chart for the outdoor unit. Locate Charging Charts on the outdoor unit and also in the Service Data Application Guide on www.upgnet.com. Follow the Subcool or the Superheat charging procedure In the Installation Manual according to the type of indoor metering device in the system, and allow ten minutes after each charge adjustment for the system operation to stabilize. Record the charge adjustment made to match the Charging Chart. 6- Permanently stamp the unit data plate with the TOTAL SYSTEM CHARGE defined as follows: TOTAL SYSTEM CHARGE = Base Charge (as shipped) + charge adder for matched indoor unit (+ or-) charge adder for actual lineset length + charge adjustments to match the Charging Chart. Subject to change without notice. Published in U.S.A. Copyright © 2017 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5452075-BTD-A-1117 Supersedes: 5121496-BTD-E-1016 8 ' s grimmat i •. � � ' ' S • "mow , — i . -s U Deck over the conc. Cone 168 s.f. 7 24 24 1 Wd Dk ! 4&0 e s I sFr (Upper) 1188 sf. Fr voFln DQ 0. D� V-t S . I � RECEIVED APR 17 2019 BUILDING _ 21 Fr G 525 s.f. 25 Ov. Lam.. Sanhweet -40 1 Google AL �. 1