Loading...
ZZ-A.pdfZZA Zipper. Zeman Associates, Inc. Geotechnical and Environmental Consulting V-2 6% .28 60 A 1rerracon Company a ON MW �Yft MAI 2 5 2� VV��Vii5l7 C) LVIYIV4v�a 7 City of Edmonds Gov o Development Services Department 1215 th Avenue North Edmonds, Washington 98020 Attention: Ms. Theresa Umbaugh Subject: Geotechnical Review Proposed Bui Residence 16105 75th Place West Edmonds, Washington Plan Review Number: 05-564 J-2322 May 23, 2006 As requested by the City of Edmonds, Zipper Zeman Associates, Inc. (ZZA) has completed third -party geotechnical review for the above referenced project located within the Meadowdale landslide hazard area in Edmonds, Washington. Preliminary geotechnical review comments were provided by ZZA in a letter dated January 4, 2006- A response letter dated February 23, 2006 by LSI Adapt was provided to us. Based on our review of the provided response, we requested additional information regarding the soil strength parameters used in the slope stability analysis. LSI Adapt responded via email, which is attached to this letter. Overall, the LSI Adapt response letter adequately addresses the review comments, in our opinion. The items discussed below are listed in order of the provided response. Response Number 1: As requested, LST Adapt reviewed their report and the previous RLA and Geoengineers reports. LSI Adapt concluded that it was unwarranted to modify their analysis as they have performed site specific subsurface explorations and analyses. While the results of their analyses may differ from other investigators, their conclusions are based on site-specific information obtained by the project geotechnical engineers. In our opinion, the analyses provided by the . engineer are in accordance with requirements of the ECDC. Response Number 2: LSI Adapt provided firther detail on the stability analyses performed and provided further detail on the strength parameters used in the analyses. We requested additional information regarding the soil strength parameters used which can be found in the attached email correspondence. As discussed above, while their interpretations may differ from other investigators, their interpretations are based on site- specific information obtained by the project geotechnical engineers, and, in our opinion, are in accordance with the requirements of the ECDC. 18905 33r1 Avenue West #117, Lynnwood, WA 98036 425-771-3304 Fax: 425-771-3549 LZA Proposed Bui Residence — Edmonds, Washington Job No. 1-2322 May 23, 2006 mr.160m, Page 2 • Response Number 3: As requested, LSI Adapt provided a slope stability analysis for the. temporary slope excavations. While there is a reduction in the factor of safety, the minimum factor of safety calculated is above generally accepted geotechnical engineering standards. In addition, the critical failure surface calculated appears to remain within the subject property bounds. Based on this information, and the fact that LSI Adapt performed a site-specific analysis, the provided response complies with ECDC requirements, in our opinion. However, due to the nature of this project, we recommend that the project geotechnical engineer monitor the slope excavations during construction.. In addition, we recommend that excavation and grading activities should be limited to the generally accepted dry season (approximately November 1 to March 31). • Response Number 4: The response is acceptable. Based on our review and the provided responses by the project geotechnical engineer, it is our opinion that the geotechnical aspects of the project generally conform to the Edmonds Development Code with respect to the Meadowdale Earth Subsidence and Landslide Hazard code requirements. We trust that this letter meets your needs at this time. Should you have any questions regarding this project, please contact us at your convenience. Respectfully Submitted Zipper Zeman Associates, Inc. Kristopher T. Hauch, P.E. Project Engineer 6;70-4� 4 ? John E. Zipper, P Principal Enclosed: Email Correspondence (May 4, 2006) CC: LSI Adapt, Inc. — Mr. Rolf B. Hyllseth, P.E. . J-2322 Fina[ ReviewOS2306.doe UNRES 1 / 24 / r