Loading...
APPROVED BLD BLD2020-0914+Architectural_Plan+10.20.2020_9.40.15_AMGENERAL NOTES: GENERAL NOTES - PLUMBING: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE. 1. DO NOT SCALE DIMENSIONS FROM THIS DRAWING FOR CONSTRUCTION PURPOSES. VERIFY PLUMBING FIXTURE DIMENSIONS IN FIELD PRIOR 2. OWNER/CLIENT, AND/OR CONTRACTOR, IS RESPONSIBLE FOR ANY AND ALL PERMITS WHICH MAY BE TO INSTALLATION OF PIPING. FOR ANY OTHER REQUIRED REQUIRED FOR THE COMPLETION OF THIS PROJECT. DIMENSIONS SEE DESIGN DRAWINGS. 3. THIS SET OF DRAWINGS/DOCUMENTS IS A REPRESENTATION OF THE DESIGN INTENT AND DO NOT INDICATE 2• WALL COVERING OF SHOWER AND TUBS WITHIN SHOWERS SHALL BE "ALL" THE BUILDING CONDITIONS AND/OR BUILDING COMPONENTS REQUIRED FOR THE CONSTRUCTION OF OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF THE PROJECT. IT IS THE CONTRACTOR'S AND SUBCONTRACTOR'S RESPONSIBILITY TO THOROUGHLY REVIEW NOT LESS THAN 70" ABOVE DRAIN INLET. MATERIALS OTHER THAN THE DRAWINGS TO VERIFY ALL THE MATERIALS REQUIRED FOR THE CONSTRUCTION OF THE PROJECT. STRUCTURAL ELEMENTS SHALL BE MOISTURE RESISTANT. 4. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, 3. PROVIDE WATER SAVING WATER CLOSET WITH 1.28 G.P.F. LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THESE 4. ALL SHOWERS AND TUB -SHOWERS SHALL HAVE A PRESSURE DRAWINGS/DOCUMENTS. BALANCE THERMOSTATIC MIXING VALVE, OR A COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING TYPE VALVE. 5. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL CAREFULLY AND THOROUGHLY REVIEW THE DRAWINGS, SPECIFICATIONS AND OTHER CONSTRUCTION DOCUMENTS AND SHALL AGREE BEFORE SUBMITTING A BID OR 5. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO COMMENCING WITH CONSTRUCTION, THAT THEY HAVE FOUND THE DRAWINGS, SPECIFICATIONS AND OTHER THE WALL IN TWO PLACES. ONE IN THE UPPER 1/3 OF THE TANKS. CONSTRUCTION DOCUMENTS TO BE FREE FROM AMBIGUITIES AND SUFFICIENT FOR THE PURPOSES INTENDED. THE LOWER POINT SHALL BE A MIN. OF 4" ABOVE THE CONTROLS. 6. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR AND ALL SUBCONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT, TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND/OR DESIGNER VERBALLY AND IN WRITING. 7. ALL TRADES SHALL REFER TO THE DRAWINGS REGARDING LOCATION OF WORK TO BE INSTALLED. 8. ALL WORK INCIDENTAL TO THE CONTRACT AND NECESSARY TO COMPLETE THE PROJECT, ALTHOUGH NOT SPECIFICALLY REFERRED TO ON THE DRAWINGS OR SPECIFICATIONS, SHALL BE FURNISHED AND PERFORMED BY THE CONTRACTOR. 9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THESE DRAWINGS/DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 10. ALL CONSTRUCTION SHALL OBSERVE AND COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND CITY, LAWS, REGULATIONS, ORDINANCES, BUILDING CODES, SUBSEQUENT STATE, COUNTY, AND CITY AMENDMENTS TO THE CODES. 11. THE CONTRACTOR SHALL OBSERVE AND COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND CITY LAWS REQUIRED FOR THE PROTECTION OF PUBLIC HEALTH, SAFETY AND ENVIRONMENTAL QUALITY. 12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 13. THE CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. 14. THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 15. DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS. MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK. 16. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND/OR PROJECT SITE. 17. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 18. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY, AS WELL AS LIABILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT AND SHALL ESTABLISH AND MAINTAIN AT ALL TIMES, ALL PROTECTIVE MEASURES AS REQUIRED TO SAVE HIS EMPLOYEES, THE PUBLIC, AND ALL OTHERS FROM BODILY HARM OR DEATH RESULTING FROM OPERATIONS RESULTING FROM THE WORK UNDER THE CONTRACT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL PAY FOR ANY AND ALL CLAIMS RESULTING FROM ANY SUCH ACCIDENT WITHOUT LIABILITY TO THE OWNER OR THE DESIGNER. 19. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 20.ALL SUBCONTRACTORS ARE TO COMMUNICATE WITH THE DESIGNER THROUGH THE GENERAL CONTRACTOR WITH ALL QUESTIONS THEY MIGHT HAVE CONCERNING THESE DRAWINGS AND/OR SPECIFICATIONS. 21.THE DESIGNER HAS MADE EVERY EFFORT TO SET FORTH IN THESE DRAWINGS/DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE DESIGNER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 22.THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS. 23. THE CONTRACTOR SHALL PROVIDE OWNER WITH PROPER INSURANCE CERTIFICATES AND PROOF OF LICENSE(S). 6. VERIFY ENTERING POINTS AND METERING LOCATIONS BEFORE INSTALLATION. 7. ALL FITTINGS, VALVES AND CONTROLS TO BE FURNISHED BY PLUMBING CONTRACTOR. 8. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL PLUMBING PERMITS WHICH MAY BE REQUIRED. 9. MINIMUM PLUMBING DWV SLOPE = 1/4" PER FOOT. 10. MATERIALS, CONNECTION FOR PLUMBING PER APPROPRIATE UPC EDITION. PER FIELD VERIFICATION. City Of Edmonds Building Department Work INTERIOR REMODEL ------------------------------------------------ --------------------------------------------- Address; 23023 74TH AVE W -------------------------------------------- --------------------------------------------- Owner ; ZIPPER --------------------------------------- Approved Date 10/26/2020 Building Official: Dow-w-m W. X pIkaic r BLD2020-0914 Permit Number GENERAL NOTES - ELECTRICAL: 1. ALL ELECTRICAL PLANS INCLUDED IN THIS SET OF DRAWINGS ARE SCHEMATIC AND REFLECT DESIGN INTENT ONLY. 2. DO NOT SCALE DIMENSIONS FROM THIS DRAWING FOR CONSTRUCTION PURPOSES. VERIFY DIMENSIONS IN FIELD PRIOR TO INSTALLATION. 3. VERIFY ENTERING POINTS AND METERING LOCATIONS BEFORE INSTALLATION. 4. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND REQUIREMENTS. 5. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL ELECTRICAL PERMITS WHICH MAY BE REQUIRED - REFER TO GENERAL NOTES #2. City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE NOTE: DM7 DESIGN RECOMMENDS THAT ALL STRUCTURAL, ELECTRICAL, HVAC AND PLUMBING BE ENGINEERED BY A WASHINGTON LICENSED PROFESSIONAL AS NECESSARY. SYMBOL LEGEND SECTION ELEVATION • DETAIL OPARTITION/WALL TYPE Q REVISION ODOOR TYPE • KEYNOTE xx FIXTURE/FINISH/ MATERIAL GWB GYPSUM WALL BOARD TYP TYPICAL ,HFFT IKIF)FX ERAL NOTES C-1 .0 PARCEL PLAN A-0.1 FLOOR PLAN -EXISTING A-1 .0 DEMOLITION PLAN A-1 .1 CONSTRUCTION PLAN 1-1 .1 REFLECTED CEILING PLAN I ORS & WINDOWS 1-2.1 INTERIOR ELEVATIONS - KITCHEN 1-2.2 INTERIOR ELEVATIONS - KITCHEN 1-2.3 INTERIOR ELEVATIONS - MASTER BEDROOM & BATHROOMS 1-2.4 INTERIOR ELEVATIONS - LAUNDRY & SHOWER ROOM 1-3.0 FIREPLACE DETAILS 1-3.1 DETAILS - TYPICAL E-1 SCHEMATIC ELECTRICAL PLAN SS-1 STRUCTURAL BY SIDESWAY ENGINEERING SS-2 STRUCTURAL BY SIDESWAY ENGINEERING IDMc DQSIGN Darcy J. Mertz Krewson, RDI, an.c. AIA Ph (425) 610. 8015 F- (425) 512 0270 PO BOX 12845 Everett, WA 98258 iMe� , PROJECT INFORMATION: OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES w W V a- N w o Z In = rn LLJ YQ LU ti = o co 0 N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: TITLE SHEET & GENERAL NOTES SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: T-1 .0 (E) WOOD DECK 36 SQ.FT. PROPERTY LINE 147.86' S89' 48' 00" E— iPLE- - - — (E) WATER SERVICE — - \\ P \ (E) LANDSCAPING F Vv\ NEL o� IAY / \ \�2C 9 Q� ?s , S�0. Ck �\ I / I \ (N) 120 GAL PROPANE TANK, 10' MIN. SETBACK FROM STRUCTURE OR PER REGULATION (VERIFY LOCATION IN FIELE PERMITS BY CONTRACTOR -------- Owner/Applicant to obtain the proper permits ;prior to installation. : -------------------------------- e 6-/ r V II / / / / / / PROPERTY: 23023 74TH AVENUE W, EDMONDS, WA. 98026-8502 PARCEL NO.: #00488800200403 (R01) LEGAL DESCRIPTION: LAKE BALLINGER LAND CO SUBDIV 1 BLK 002 D-03 - BEG 296.03FT E OF NW COR IT 4 TPB TH S81 FT M/L TO A FENCE TH S89*48 OOE ALG FENCE LN 1 OOFT M/L TO INTERURBAN R/W TH NLY ALG SD R/W TO N IN IT 4 TH W ALG SD N IN TPB LOT SIZE: 0.26 ACRE(S) (NO CHANGE) ZONING: RS-8 OWNER / CONTACT: JOHN ZIPPER KATHY ZIPPER 23023 74TH AVENUE W EDMONDS, WA. 98026 STRUCTURAL ENGINEERING: SIDESWAY ENGINEERING CHRIS BERNARDS, PE, SE, LEED AP NOTE: • NO EXISTING OR PROPOSED SEPTIC TANKS, WELLS, DRAINFIELDS, OR RESERVE AREAS FOUND AT dave.snohd.org. • NO AREAS OF DISTURBANCE TO PROPERTY PROPOSED. PROPOSED WORK IS WITHIN THE EXISTING DWELLING. • NO NEW OR REPLACED HARD SURFACES, ROOF AREA, PAVEMENT, ETC. PROPOSED. ALL EXISTING HARD SURFACES, ROOF AREA, PAVEMENT, ETC. TO REMAIN. • NO EXPOSED SOILS ARE EXPECTED DURING THE COURSE OF CONSTRUCTION. • NO NEW STRUCTURES, DRIVEWAYS, PARKING AREAS, SIDEWALKS, OR PATIOS PROPOSED. • NO AREAS OF DISTURBANCE PROPOSED. PARCEL PLAN / AREA OF PROJECT 2436 SCALE: 1 "=10'-0" 11 A 7 SCALE: 1"=20'-O" NORTH Dmc DQSIGN Darcy J. Mertz Krewson, RDI, aos AIA Ph (425) 610. 8015 F— (425) 512 0270 PO BOX 12845 Everett, WA 98258 s�„ ,2,m. 1. PROJECT INFORMATION: W W la a_ CL N w CD v! = Z Or) LLJ Y Q vi Lu = o 0 N N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26I2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 0710112020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: PARCEL PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: C-1 .0 WINDOW 3°x5o FX DN 21tu4io 2ttx4io 3'-11" AFF 3'-11" AFF POWDER ROOM KITCHEN] j 2 2— " 2' 2•-44- 1 BOTTOM OArrERr I BEDROOM 2•_;I BEDROOM n iN N a AUNDRY N x� 6N2RY -81 #2 #3 I Hi. BOTTOM OF CENTER BEAM 1 N II ------- ELEC II ELEC METER I ^ PANEL UP I / II DINING I I 6'-• 2'-6" 2'-01• 2'-6"Ej ' AREA I I iV 5'-9• •-0• a- • BATH N HVAC O 2 —4"/ FAMILY I * io II UP O 4•-10• 2'-6" 3'-C4• 3'-4" ROOM II m BEDROOM II a L 1 #1 ` I LIVING II 5'—O• •_p• 4•-0" 4'-0- 12'-7' ROOM II I a —11k" 1 7-104" ±2'_9• 2t tx6o 3'-10" AFF I BO M OF CEIRI BEAM UP 54x48 1'-6" AFF FX 5hO FX 1 •-6" AFF 10•-0• UP 21'— 1" 2 DECK AS -BUILT FLOOR PLAN 2436 SCALE: 1 /4"=P-0" 11 A 7 SCALE: 1 /8"=1,0" DM- DQSI(;N Darcy I Mertz Krewson, RDI, an.c. AIA Ph (425) 610. 8015 F— (425) 512 0270 PO BOX 12845 Everett, WA 98258 i PROJECT INFORMATION: Lu L la - UJ 3 N w N CD z = rn LU LLJ Q I � Lu ti O 0 N N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26I2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/0t/2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: FLOOR PLAN EXISTING SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: A-0.1 (E) PLUMBING STACK TO BE RELOCATED AS NECESSARY TO ACCOMMODATE PROPOSED FLOOR PLAN POWDER R DYI� A. �W of NASHl�c OM ssrONAL 10/01/2020 REVIEWED FOR CONFORMANCE WITH STRUCTURAL CALCULATIONS DATED 08/19/20 �r-- Li UNDR� / i r-7 Imo__ rr � FIELD VERIFY RELOCATE STEP PER PROPOSED FLOOR PLAN •III II I FAMILY ROOM REMOVE GREENHOUSE • WINDOW ENTRY 36x5°FX TRIANGULAR 2 -g2 3'-2' 5')0" WINDOW ABOVE FIELD - DOOR TO BE VERIFY 1 -g REMOVED FIELD VERIFY �(N) OPENING FOR WINDOWS WITHIN LJ (E) WALL KITCHEN w� o� ❑� (E) SUPPORT POST TO REMAIN (TYR OF 2) REMOVE STEP TO LEVEL FLOOR • I r'C 1� N I I II REMOVE (E) FIREPLACE AND CHIMNEY. REFER TO I 1 STRUCTURAL SHEET SS-2. �C —7� ^ LIVING -I ROOM L TRIANGULAR WINDOWS o II ABOVE TO BE REPLACED REMOVE WINDOW REMOVE WINDOW � 10'-0" 54x48 FX 54x48 FX 1'-6" AFF 1'-6" AFF DECK REMOVE Ex410NDOW 3'-11" AFF ±3,_5.. VERIFY REMOZ1Ex41oNDOW 3'-11" AFF wa w v_ 4N) OPENING FOR WINDOW WITHIN (E) WALL lei o BEDROOM I �� BEDROOM M (N) OPENING FOR (N) #2 J #3 WINDOW WITHIN (E) WALL ------- (E) ELECTRICAL METER � (E) ELECTRICAL _Z: -0"_ 3" PANEL TO REMAIN J `CJI,T� -\\ FIELgD'I '�_V4E; VERIFY I o' (N) OPENING WITHIN (E) WALL D D BEDROOM Q m� #1 DEMOLITION PLAN 24x36 SCALE: 1/4"=V-0" LEGEND T __ T EXISTING FIXTURE TO BE REMOVED L J / EXISTING DOOR TO BE / RELOCATED AND/OR REMOVED / EXISTING WALL TO BE REMOVED EXISTING EXTERIOR WALL TO REMAIN EXISTING INTERIOR WALL TO REMAIN ____ EXISTING WINDOW TO — --� BE REMOVED NOTES: • DEMOLISH WALL AS SHOWN. •DEMOLISH DOORS AND/OR WINDOWS AS SHOWN. • EXISTING TO REMAIN. •EXISTING HVAC EQUIPMENT TO BE REMOVED. D m DESIGN 7 Darcy J. Mertz Krewson, Ph: RDI(4?§�oc. AIA10. Fax: (425) 512. 0270 PtYFsI`fi 1'f, WA. 98958 PROJECT INFORMATION: 0� W U w Z U N c��l Lu CD �/ m 2 LLJ Y _ C/) Lu Zz O ICJ ­3 64 W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 1� CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: DEMOLITION PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: A-1.0 1015 DOOR & WINDOW SCHEDULE: MODEL / FRAME KEYNOTE MATERIAL MATERIAL AND MATERIAL AND NO. DESCRIPTION MANUFACTURER NUMBER FINISH FINISH DIMENSIONS NOTES 30x70 SLIDING D101 SLIDING GLASS MARVIN ESSENTIAL TBD TBD 30 FIXED PANEL (4) HORIZONTAL MULLIONS, DIVIDED EQUALLY COLLECTION TOTAL 6FT WIDE D102 ENTRY DOOR FRANK LUMBER TRADITIONAL, 1 -CITE, 1 -PANEL WOOD WOOD 3ox7o WITH 20 SIDELITE F-6701 o (1) 34x7o D103 PASSAGE DOOR WOOD WOOD (1) 2 x7 D104 SLIDING POCKET WOOD WOOD (2) 3ox7o DOOR W101 FIXED PICTURE MARVIN ESSENTIAL TBD TBD (3) 3ox36 (2) HORIZONTAL MULLIONS, DIVIDED EQUALLY WINDOW COLLECTION ESSENTIAL VARIES - REFER TO W102 TRIANGLE MARVIN SPECIALITY TBD TBD SHEET-2.0 SHAPE (3) 2x4 ALL: (2) HORIZONTAL MULLIONS, DIVIDED EQUALLY. W103 CASEMENT MARVIN ESSENTIAL COLLECTION TBD TBD (1) 30x4,o KITCHEN: (2) OPERATIONAL WITH FIXED CENTER (1) 3ox2o PANEL W104 GLIDER, MARVIN ESSENTIAL TBD TBD (3) 3ox1s TO BE INSTALLED BELOW W101 TO ACHIEVE LOOK HORIZONTAL COLLECTION OF SINGLE WINDOW. REFER TO SHEET 1-2.0. LAUNDR FURR-OUT INTERIOR OF WALL AS NECESSARY TO ACCOMMODATE PLUMBING &/OR INSULATION EXISTING WINDOW TO REMAIN (TYP.) FRAME -IN (E) DOOR OPENING (TYP) (E) BEAM (TYP. ABOVE), ALIGN (N) WALL BELOW, FIELD VERIFY. RELOCATED STEP EXISTING WINDOW TO REMAIN (TYP.) A. �W OF WAsHl�� zN L ti SSIONAL 10/01/2020 REVIEWED FOR CONFORMANCE WITH STRUCTURAL CALCULATIONS DATED 08/19/20 FRAME -IN (E) DOOR OPENING (TYR) i IVA ii tR FURR-OUT INTERIOR OF WALL AS NECESSARY TO • ACCOMMODATE (N)N) � > INSULATION W103 (N)(3�OWIINODOWS 3'-5" AFF, - SUPPORT POST ENGINEER ENTRY KITCHEN I • N a D102 0 BOTTOM OF • RAFTER a o, N BOTTOM OF CENTFER BEAM a (E) BEAM (TYP. ABOVE) DINING b AREA FAMILY ROOM �w LIVINGII og ROOM (N) WINDOWS ®32' ABOVE FINISHED FLOOR TYP. OF 3)• o o - a W101 W104 W102(N) 6' SLIDING GLASS LL (ABOVE) DOOR TO REPLACE (E) • • D101 11,3'-0" 3'-0"L L 3'-0" 1, (E) DECK W/RAILING (TO REMAIN) •CENTER TO POST & BEAM (ABOVE) INFILL WALL ABOVE DOOR WHERE WINDOW HAS BEEN REMOVED (N) WINDOW 21140 Y-11" AFF t3'-4" L 5'-0" MASTER BEDROOM 00 SHOWER NICHE STRUCTURAL LEGEND: T x6 DF#2 FOR SPANS OF LESS THAN 6' qMFTYPICAL REFER TO SHEET SS-2. EXISTING EXTERIOR WALL TO REMAIN •HDR 4x6 DF#2 W/(1) JACK, (1) KING STUD. REFER TO SHEET SS-2. EXISTING INTERIOR WALL TO REMAIN •(3) 2x4 DF STUD FULL HEIGHT W/A35 EA SIDE @ ALL PLATES. REFER TO SHEET SS-2. NEW FULL HEIGHT WALLS - •46 DF#2 OR 48 DF#2 RIPPED TO WIDTH CONSTRUCTION TO MATCH EXISTING OF THE ROUGH SAWN BEAM FULL HEIGHT TO OR PER STRUCTURAL ENGINEERING. RIDGE BEAM. REFER TO SHEET SS-2. NOTE: •(3) 2x6 DF STUD OR 46 DF#2 FULL HEIGHT BETWEEN WINDOWS/DOOR W/A35 EA SIDE @ • STRUCTURAL ENGINEERING TAKES PRECEDENCE. ALL PLATES. REFER TO SHEET SS-2. • EXISTING 6x6 DF POST (TO REMAIN). • 2x FRAMING OR PER ENGINEERING AS APPLICABLE. SPACE LEFT BY CHIMNEY REMOVAL •INFILL WITH 2x FRAMING TO MATCH. REFER TO SHEET SS-2. • RAISE FLOOR TO ALIGN WITH EXISTING. •USE WATER RESISTANT GYPSUM BACKING BOARD ATTACHED WITH SCREWS SPACED NO MORE THAN 8"O.C. BEHIND ALL SINKS, SHOWER, BATH TUB & RESTROOM FIXTURES. 2'- 2'-6" 3•_0" DOOR 241 I MASTER BATHROOM 000"•• FURR-OUT INTERIOR OF 2 -5 WALL AS NECESSARY TO ACCOMMODATE PLUMBING &/OR INSULATION �U 2._4„ (E) o BEDROOM �7 FAMILY EXISTING WINDOW 69"• TO REMAIN (TYP.) •USE WATERPROOFING MEMBRANE AT SHOWER FLOOR AND BASE AREA, AND ON SHOWER WALLS AND BATH TUB SURROUNDS. WATERPROOFING MEMBRANE: MAPEI MAPELASTIC AQUA DEFENSE OR EQUAL. •AVOID USE OF ORGANIC (MASTIC TYPE) ADHESIVES IN SHOWER AND OTHER WET AREAS. 103 \L x ¢ • SHOWER PAN SLOPE TO BE 1 /4" PER FOOT TO FLOOR DRAIN. o •PROVIDE ADDITIONAL SUPPORT AS NECESSARY AT ALL BATH TUB AND SHOWER LOCATIONS. FLOOR STRUCTURE SHOULD BE CAPABLE OF CARRYING THE WEIGHT OF THE BATH TUB WHEN FILLED TO CAPACITY. (N) OPENING WITHIN (E) WALL • VERIFY WATER HEATER CAPACITY IS RELOCATED ATTIC SUFFICIENT FOR PROPOSED USAGE. ACCESS HATCH IN CEILING - EXACT LOCATION TBD IN FILED PROVIDE BLOCKING IN WALLS AS NECESSARY FRAME -IN (E) DOOR OPENING (TYR) FOR FUTURE GRAB BARS TO SUPPORT A MIN. OF 200LBS - 300LBS OF PULL. APPLY (N) SIDING OVER EXISTING SIDING CONSTRUCTION PLAN D 24x36 SCALE: 1/4"=1'-O" 11x17 SCAT F: 1 /8"=1'-O" GENERAL NOTES: a. NEW CONSTRUCTION TO MATCH EXISTING OR BETTER. b. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. c. ALL CONSTRUCTION SHALL OBSERVE AND COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND CITY, LAWS, REGULATIONS, ORDINANCES, BUILDING CODES, SUBSEQUENT STATE, COUNTY, AND CITY AMENDMENTS TO THE CODES. d. ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE AND ANY APPLICABLE STATE, COUNTY, OR LOCAL REGULATIONS. e. CAULK OR WEATHERSTRIP ALL JOINTS AND PENETRATIONS TO HEATED SPACES. f. ALL GLAZING TO COMPLY WITH WSEC 2015. D M DESIGN 7 Darcy J. Mertz Krewson, Ph: RDI(4?§�oc. A1610. Fax: (425) 512, 0270 f" fit'f, WA. 98958 PROJECT INFORMATION: 0� W U w W � N w 04 CD m U) 2 LLJ YQ _ W Lu ti z o O ICJ 04 W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 1 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 1� CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: CONSTRUCTION PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: A-1.1 1015 (LOCAL EXHAUST FANS SHALL BE PROVIDED IN ! ,EACH KITCHEN, BATHROOM, WATER CLOSET, ■ !LAUNDRY ROOM, INDOOR SWIMMING POOL, SPA,( ■AND OTHER ROOMS WHERE WATER VAPOR OR • !COOKING ODOR IS PRODUCED. IRC 1507.4 CENTER SINK TO WINDOWS \' \ I 11 I II � \ r—-- oW I III o I LAUNDRY/ SHOWER ROO, 1. 2'-11' i. t2'-6' li. 3'-10" i. f4'-5" 1. W Q 3 0 36"x36" W/H KITCHEN( = r / UNDER II COUNTER REFRIG. II / < J o r- I � � II L II D I I I t3" FAMILY ROOM I I I 90(N) DOUBLE -SIDED FIREPLACE TO REPLACE (E) I I (E) DECK W/RAILING (TO REMAIN) -]!I, �`I0/01/2020 REVIEWED FOR CONFORMANCE WITH STRUCTURAL CALCULATIONS DATED 08/19/20 MASTER ENTRY UP '� BATHR00 HDINING 141 AREA II II LIVING II ROOM II II II II I 6 c I II ---- L —-J- 1 •\ a I I — m MASTER w BEDROOM -7 i 3._5.. / 0 SHOWER NICHE (E) ELEC. V CORNER BENCH PANEL a a / STORAGE (N) LINEN \ CABINET • TO CEILING \1 J o NEW STEP TO o (E) DECK AT SLIDING DOOR, t 12"H TOTAL • NLo o I • Q� o BEDROOM LL M W (N) BATH TUB TO REPLACE (E)-]�l UP PROPOSED FLOOR PLAN D 24x36 SCALE: 1/4"=1'-O" 11x17 SCAI F: 1 /8"=1'—O" NOTE: • USE WATER RESISTANT GYPSUM BACKING BOARD ATTACHED WITH SCREWS SPACED NO MORE THAT 8" O.C. BEHIND ALL SINKS AND WET AREAS. •FINAL CABINETRY DESIGN, SIZES AND CONFIGURATION TO BE FINALIZED BY HOMEOWNER AND CABINET MANUFACTURER AND MAY VARY SLIGHTLY FROM DESIGN INTENT SHOWN IN THIS SET OF DRAWINGS. REFER TO CABINETRY SHOP DRAWINGS. •FOR CABINET INFORMATION, REFER TO ELEVATION SHEETS 1-2.1, 1-2.2, 1-2.3, 1-2.4. • NEW HARDWOOD FLOORING THROUGHOUT, •NEW WINDOWS, REFER TO ELEVATIONS SHEET 1-2.0. •NEW WINDOWS & SLIDING DOOR PER STRUCTURAL ENGINEERING AS APPLICABLE. SEE ELEVATION SHEET 1-2.0. STRUCTURAL 46 DF#2 FOR SPANS OF LESS THAN 6' TYPICAL. REFER TO SHEET SS-2. •HDR 4x6 DF#2 W/(1) JACK, (1) KING STUD. REFER TO SHEET SS-2. •(3) 2x4 DF STUD FULL HEIGHT W/A35 EA SIDE @ ALL PLATES. REFER TO SHEET SS-2. •4x6 DF#2 OR 4x8 DF#2 RIPPED TO WIDTH OF THE ROUGH SAWN BEAM FULL HEIGHT TO RIDGE BEAM. REFER TO SHEET SS-2. •(3) 2x6 DF STUD OR 4x6 DF#2 FULL HEIGHT BETWEEN WINDOWS/DOOR W/A35 EA SIDE @ ALL PLATES. REFER TO SHEET SS-2. • EXISTING 6x6 DF POST (TO REMAIN). •INFILL SPACE LEFT BY CHIMNEY REMOVAL WITH 2x FRAMING TO MATCH. REFER TO SHEET SS-2. D m DESIGN 7 Darcy J. Mertz Krewson, Ph: RDI(4?§�oc. A1610. Fax: (425) 512, 0270 PVVI`€-, f, WA. 98958 PROJECT INFORMATION: W 0� U w w N W N CD m U) = W Y Z W 06 Zz W r` = o N ­3 N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 &D ENGINEERING ADDED 08/20/2020 E HI SCHEMATIC ADDED 09/03/2020 1� CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: FLOOR PLAN PROPOSED SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-1.0 1015 NOTE BATHROOM VENTILATION FANS SHALL BE UL LISTED FOR CEILING MOUNT AND TUB/SHOWER ENCLOSURE WHEN GFCI PROTECTED. FANS SHALL COMPLY WITH WA VENTILATION CODE. FANS SHALL ALSO BE ENERGY STAR® CERTIFIED WITH A BUILT—IN SPEED SELECTOR, CHOOSE FROM 50-80-110 CFM. KITCHEN HOOD VENT CFM®0.1" S.P.: SINGLE BLOWER, 4 SPEED: 204-625 CFM DUAL BLOWER, 4 SPEED: 420-1015 CFM KITCHEN HOOD VENT LAUNDRY/ SHOWER ROOM FAMILY ROOM • o0 t10'-7• ------------- KITCHEN \\ ENTRY I I 1 MCI i _�— *� a� 0I sl M -H� ZII y I I \1 L 11 11� OPTIONAL• FOR GENERAL LIGHTING, --� MOUNT TRACK FIXTURE AT CEILING (E) VAULTED CEILING ALIGNED WITH BEAM, DIRECT TO REMAIN LAMPS TO HIGHLIGHT FLOOR AREA / I LIVING - I I II — — ROOMUL ' DININGI �I ' AREA ° 1 ll9 ULy 44 I I I FIELD - ----------L I\ VERIFY O O �a On mZ �0- (E) EXPOSED CEILING RAFTER (TYP - VERIFY IN FILED) — MASTER —>(E) CEILING TO REMAIN BATHROOM 3 I \ MASTER BEDROOM 1 I I I I I I I ABOVE COUNTERTOP ` \/ 3 Z(E) LIGHTING TO ATTIC REMAIN •Qj ACCESS STORAGE CEILING TO REMAIN (E) BEDROOM ®®A (E)LIGHTING TO REMAIN ;7 REFLECTED CEILING PLAN NOT TO SCALE LEGEND: CEILING MOUNTED VENTILATION FAN 50-80-110 CFM. SWITCH I3 SWITCH 3—WAY O.C. ON CENTER NOTE: ALL CONSTRUCTION SHALL OBSERVE AND COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND CITY, LAWS, REGULATIONS, ORDINANCES, BUILDING CODES, SUBSEQUENT STATE, COUNTY, AND CITY AMENDMENTS TO THE CODES. GENERAL CONTRACTOR TO CONFIRM & PLACE ALL SWITCHING PER HOME OWNER. isEXISTING LIGHT FIXTURE LOCATIONS TO BE VERIFIED IN FIELD. REMOVE OR RELOCATED EXISTING LIGHT FIXTURES AS NECESSARY TO ACCOMMODATE NEW SPACES. •TIE INTO EXISTING SWITCHING & WIRING AS NECESSARY TO ACCOMMODATE NEW OR RELOCATED LIGHTING. •KITCHEN HOOD WITH INTEGRATED LIGHTING TO HAVE 2700K CCT LAMPS. KITCHEN HOOD WITH REPLACEABLE LAMPS IS PREFERRED SO THAT THE CORRECT CCT LAMPS CAN BE PURCHASED AND INSTALLED AT ANY TIME. •RECESSED FIXTURES AT SHOWERS TO HAVE WET RATED TRIM KITS. •LOCATE BATTERY POWERED SMOKE/ CARBON —MONOXIDE DETECTORS PER 2015 WASHINGTON STATE ENERGY CODE SECTIONS R314 & R315. LIGHTING CONSULTANT LEGEND: a = SCONCE = FLUSHMOUNT FIXTURE = SEMI—FLUSHMOUNT FIXTURE s f� = HANGING PENDANT Y = RECESSED CAN (% . INCH APERTURE) ADJUSTABLE RECESSED CAN g = STEP LIGHT = SECURITY FLOODLIGHT 0 0 0 = BATHROOM WALL —FIXTURE — — — = LED TAPE FIXTURE, UNDER CABINET/SHELF+ C� = LINEAR TUBE FIXTURE = TRACK FIXTURE p = MONOPOINT FIXTURE * FOR UNDER SHELF FIXTURE: ROUTE OUT 3/8' DEEP CHANNEL 1- FROM FRONT OF SHELF FOR FIXTURE, 12v LEAD TO RUN WITHIN HOLLOW AND CONNECT WITH REST OF THE FIXTURES/TRANSFORMERS. SEE LIGHTING SPECIFICATIONS FOR FIXTURE INFORMATION. LIGHTING CONSULTANT: IDM� DESIGN Darcy J. Mertz Krewson, RDI, ass AIA Ph (425) 610. 8015 F­ (425) 512 0270 PO BOX 12845 Everett, WA 98258 9, o 'o, oM, �.9' ° M ° ; ,m, ,. o °err; Lzc zo PROJECT INFORMATION: W W LPL CL W N w 0 0c) = Lu rs Lu = NY L1� 0 W z 0O a- = o c� a IN , N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/i6/2020 C REVS PER COMMENTS 0710112020 �D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: REFLECTED CEILING PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: -1 . l STRUCTURAL T x6 DF#2 FOR SPANS OF LESS THAN 6' TYPICAL. REFER TO SHEET SS-2. •HDR 4x6 DF#2 W/(1) JACK, (1) KING STUD. REFER TO SHEET SS-2. •(3) 2x4 DF STUD FULL HEIGHT W/A35 EA SIDE @ ALL PLATES. REFER TO SHEET SS-2. •4x6 DF#2 OR 48 DF#2 RIPPED TO WIDTH OF THE ROUGH SAWN BEAM FULL HEIGHT TO RIDGE BEAM. REFER TO SHEET SS-2. •(3) 2x6 DF STUD OR 46 DF#2 FULL HEIGHT BETWEEN WINDOWS/DOOR W/A35 EA SIDE @ ALL PLATES. REFER TO SHEET SS-2. • EXISTING 6x6 DF POST (TO REMAIN). f4'-1" (E) STRUCTURAL BEAM 6'-0" ® Y 10/ 1512020 REVIEWED FOR CONFORMANCE WITH STRUCTURAL CALCULATIONS DATED 08/19/20 STRUCTURAL SUPPORT• POST (BEYOND) f5'-1" I 1, I I --— — — — — — — II --— — — — — — — II F I � 0 M Kloij 15'-2" FIELD VERIFY I I I I I I I I I I ENTRY DOOR WITH • D102 SIDELITE TO REPLACE EXISTING DOUBLE DOORS i N O ROOF SUPPORT STRUCTURE (BEYOND) MINI —SPLIT UNIT, WALL MOUNTED. FINAL LOCATION TO BE VERIFIED IN FIELD. 5'-9„ FIELD VERIFY f1'-11" 2'-10" f1'-4" INTERIOR ELEVATION - f AOTEFARA,TM-0C it 11 x17 SCALE: 1 4 =1 -0 11 QD RAISE FLOOR TO ALIGN WITH (E) KITCHEN FLOOR LEVEL f 13" (FIELD VERIFY) "O INTERIOR ELEVATI Calx3c ��I�TI--�'2, ��,t� 1 x1 SCALE: 1 =1 - 7 0 6' -1 " SLIDING DOOR NOTES: REFER TO DOOR & WINDOW SCHEDULE ON SHEET A-1.1 FOR KEYNOTE NUMBER. MINI -SPLIT UNIT, WALL MOUNTED. FINAL 3'-6" LOCATION TO BE VERIFIED IN FIELD. o •i W103 V CLOSET CABINETRY 0 I m o INTERIOR ELEVATION-2Qx,��TFRLEBE,��'OP 11 x17 SCALE: 1 4 =1 -0 (E) STRUCTURAL BEAM ol 3'-01, 3'-0"Ool 3'-0" ol ALIGN WITH ALIGN WITH ALIGN WITH WINDOW BELOW WINDOW BELOW WINDOW BELOW STRUCTURAL SUPPORT,* POST (BEYOND) ROOF SUPPORT r � STRUCTURE (BEYOND) I � I I �I I I / I I • CENTER TO BEAM (ABOVE) 1'-0" •(TYPICAL) o I 3'-0" INTERIOR ELEVATI Mx3c SS E Tj42'WA-L x1 L _ -0 Q0 DES I GN Darcy J. M ertz Krewson, Ph: RDI(4255 oc. A1910. Fax: (425) 512. 0270 P1 n htsp, d 1�o'E�1,Q $'u sed Without Express Agreement. © pyn t 1 2 `bS, �j Design /Mertz Design & PVtiehtf, WA_ 982,9 i PROJECT INFORMATION: W U w n Z W N N 0 w >_ D c) U) = Z rn LU � Q Ise L.L 06 w ti Z z O 0-= N (Z)— O M o N N w STAMP: SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A B AS -BUILT REV. LAYOUTS 03/26/2020 04/16/2020 C REVS PER COMMENTS 07/01/2020 �D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 10 CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: NTER OR ELEVATIONS DOORS 8c SCALE: � `n /DESIGN1=1 v v DATE ISSUED: 07/13/2020 SHEET NUMBER: 2�0 3015 WALL CAP - MATCH COUNTERTOP rBACKSPLASH COUNTERTOP (E) EXPOSED RAFTERS (E) STRUCTURAL OPEN CEILING MINI -SPLIT UNIT, WALL TILE n(ANGLED - TYP) (BEAM (ANGLED - TYP) FMOU E VERIFl DL ILOTION FIELD• W� �Q o� w� ao f xx� W U L 7 O / \ �El i o / OPEN o o SHELVING /� �\ HALLWAY TO 0 W iv BEDROOMS FULL 14" DEEE EIGHT PANTRY I (BEYOND) ma3 CAB ETS 4'-ie 6'-8" ,�• FLOATING SHELVING r MENT HOOD L ®STOVE _ I Ld I I I I I I I I // I I I / I I I I E_E�r =5 1/DRAWER SICABINETE DISHEIR o a KITCHEN / DINING AREA ELEVATION - B 24"x36" SCALE: 1/2"=1'-0" 11 "x17" SCALE: 1 /4"=1'-0" (E) STRUCTURAL BEAM 7r-- , WALL LOCATION IN FIELD. LE L-CORNER CABINET TO FIT* W/PULL—OUT SHELVING KITCHEN ELEVATION -A 24"x36" SCALE: 1/2"=1'-0' 11 "x17" SCALE: 1 /4"=1' 0" NOTE: •FINAL CABINETRY DESIGN, SIZES AND CONFIGURATION TO BE FINALIZED BY HOMEOWNER AND CABINET MANUFACTURER AND MAY VARY SLIGHTLY FROM DESIGN INTENT SHOWN IN THIS SET OF DRAWINGS. REFER TO CABINETRY SHOP DRAWINGS. ®ALL APPLIANCES TO BE INSTALLED PER MANUFACTURERS INSTRUCTIONS, PROVIDE REQUIRED CLEARANCES AS NECESSARY. IDM- DQSI(;N Darcy I Mertz Krewson, RDI, aos AIA Ph 14251610.8015 F� 14251512 0270 PO BOX 12845 Everett, WA 98258 iMe� , PROJECT INFORMATION: W W a_ CL N w CD v! = or) LLJ YQ v� Lu = O Co N L1J STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/0V2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: INTERIOR ELEVATIONS KITCHEN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-2.1 COU (E) EXPOSED CEILING RAFTERS DECORATIVE 2x TRIM — DESIGN/BUILD BY GC IN THE FIELD, FASTEN TO (E) SUPPORT POST & BOTTOM OF RAFTERS AT WALLS • 6'-1" V-2" 2'-2" 2'-0" V-2" " 3'-9" 7'-10" 4'-8" 7'-10" \/IF\A/ A \/IF\A/ '2 \/IF\A/ 7 w o: RAISED AREA OF F FILED VERIFY FIELD VERIFY (E) STRUCTURAL SUPPORT POST WALL CAP — MATCH COUNTERTOP ISLAND COUNTERTOP SUPPORT POST I "sac+ w I I I 3'-4" L V-2" 6-1 \/IF\A/ 1 C1Q:�IS'>l6f�li�:y KITCHEN ISLAND ELEVATIONS 24"x36" SCALE: 1/2" 1 0' 11 "xl 7" SCALE: 1 /4"=1'-0" � NOTE: •FINAL CABINETRY DESIGN, SIZES AND CONFIGURATION TO BE FINALIZED BY HOMEOWNER AND CABINET MANUFACTURER AND MAY VARY SLIGHTLY FROM DESIGN INTENT SHOWN IN THIS SET OF DRAWINGS. REFER TO CABINETRY SHOP DRAWINGS. ALL APPLIANCES TO BE INSTALLED PER MANUFACTURERS INSTRUCTIONS, PROVIDE REQUIRED CLEARANCES AS NECESSARY. (E) EXPOSED RAFTERS (E) STRUCTURAL OPEN CEILING rDECORATIVE 2x TRIM AT ZT (ANGLED - TYP) BEAM (ANGLED - TYP) / BOTTOM OF RAFTER AT WALL t4" L -b OPEN SHELVING OPEN SHELVING I OPENING TO co FAMILY ROOM I (BEYOND) o U R CABINET ,24"I EEP MICROWAVE — DRAWERS INET EP�E E IG. EEP I ® OPEN SHELVING (2) .....��. VENT HOOD ®STOVE L _ — — — — _ - 0 'ii OPEN SHELVING (2) COUNTE BACKSP I o "n H o o fO I 0 1 CONTINUOUS WOOD BEAM MANTEL • CAI I SIDED FIREPLACE • I CA[DOUBLE ET DRAWERS CORNER CABINET o I I I I _OOR 4'-6" YFEENNURNME l'-2" 3'-8" V-2" I L 4'-6" DOCKING DRAWER I. 2" MIN 36" REFRIG. COUNTER—DEPT Z" MIN t15'-11" 30" RANGE 2'-0" • 2TOP ASH TILE KITCHEN / LIVING AREA ELEVATION - C 24"x36" SCALE: 1 /2"=P-0" 11 "xl 7" SCALE: 1 /4"=1' O" IDM- DQSI(;N Darcy I Mertz Krewson, RDI, an— AIA Ph (425) 610. 8015 Fax (425) 512 0270 PO BOX 12845 Everett, WA 98258 i PROJECT INFORMATION: w W a- CL N w CD V ! 1 or) LLJ YQ v) Luo C" N Co W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/0V2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ I CITY REVIEW COMMENTS1 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: INTERIOR ELEVATIONS KITCHEN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-2.2 NOTE: •FINAL CABINETRY DESIGN, SIZES AND CONFIGURATION TO BE FINALIZED BY HOMEOWNER AND CABINET MANUFACTURER AND MAY VARY SLIGHTLY FROM DESIGN INTENT SHOWN IN THIS SET OF DRAWINGS. REFER TO CABINETRY SHOP DRAWINGS. •REFER TO DOOR & WINDOW SCHEDULE ON SHEET A-1.1 FOR KEYNOTE NUMBER. TILE WAINSCOTING -TOWEL BAR rHANGING BAR ADJUSTABLE HANGING BAR ISHELVING SHELF OPEN / COUNTER ADJUSTABLE SHELVING 0 DOORS REMOVED MASTER BATHROOM (BEYOND) D104 3'-0" I. 6'-5" W" MASTER BEDROOM ELEVATION - F 24"x36" SCALE: 1 /2"=1' 0" 11 "xl 7" SCALE: 1 /4"=1' O" 0 TILE BACKSPLASH COUNTERTOP 1 & WAINSCOTING -� rc m� .H • ELEVATION J MASTER CLOSET ELEVATION - H 24"x36" SCALE: 1 /2"=1' 0" 11 "xl 7" SCALE: 1 /4"=P-0" 1'-4" 1'-0" MIN t� riul ® _ 1 o ill------------- y 1-------01:=�_==_=fly _=_1 1-_-- 3'-0- 9" V-3" I \\4—, I n ELEVATION I FAMILY BEDROOM ELEVATIONS EQ. t EQ. 24"x36" SCALE: 1 /2"=l'-O" 11 "xl 7" SCALE: 1 /4"=l'-O" KEY PLAN: • 9 LL CLOSET CABINETRY D103 � M 2" 3'-9" 3'-5" 3'-0" B'-9" 2'-0" 21'-9" U W104 0 I 0 n J -H i 2'-0" 1'-7" 2'-8- 4'-5" MASTER BATHROOM & BEDROOM ELEVATION - G MINI -SPLIT UNIT, WALL MOUNTED. FINAL LOCATION TO BE VERIFIED IN FIELD.--\BACKSPLASH TILE COUNTERTOP 24"x36" SCALE: 1 /2"=1'-0" 11 "xl 7" SCALE: 1 /4"=1'-0" CENTER TOWER W/ADJUSTABLE SHELVING `w '> • o � CLOSET CABINETRY o W104 I * I I 'ODn m SINK E T.ET SINK E — E 2,_0" 12,_0" 7'-4- MASTER BATHROOM ELEVATION - E MASTER BEDROOM & BATHROOM ELEVATION - D 24"x36" SCALE: 1 /2"=1' 0" 24"x36" SCALE: 1 /2"=1' 0" 11 "xl 7" SCALE: 1 /4"=1' O" 11 "xl 7" SCALE: 1 /4"=1' O" DMc DQSIGN Darcy J. Mertz Krewson, RDI, an.c. AIA Ph (425) 610. 8015 Fax (425) 512 0270 PO BOX 12845 Everett, WA 98258 A1 11- 2,.Ma. "„o "xa w„"i „ A,2,m."1, °�9e PROJECT INFORMATION: W W a- CL N w CD v! = or) LLJ YQ 06 Lu Co 0 O Co 0 N ) W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/0V2020 ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: INTERIOR ELEVATIONS MASTER BEDROOM & BATHROOMS SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-2.3 ZHEN & ' LIVING ROOM w (BEYOND) DOUBLE SIDED FIREPLACE I I I 6'-0" V-3" 3'-6" 4'-11' ELEVATION R COUNTERTOP `w >o �w M� i•> c OO OO c 5'-2" ELEVATION P -H LAUNDRY /SHOWER LOUVERED DOOR TO WATER PROVIDEHEATER TO ROOM (BEYOND) REQUIRED AIRCIRCULATION—\ io c m � D104 • 3'-4" 1. 8" 3'-0" 3'-10" 2'-7" ELEVATION Q rFAMILY ROOM / (BEYOND) 1:;7 D104 3 -3" V-O" 3 -0" 1 -0" 2 -9" FAMILY ROOM ELEVATIONS 24"x36" SCALE: 1 /2"=1' 0" 11 "x17" SCALE: 1 /4"=1' 0" BENCH WITH HOOKSSTORAGE & S I STORAGE MIN I I I I I / 1'-6" 3'-5" 3'-0" FIELD VERIFY ELEVATION O ELEVATION N KEY PLAN: NOTE: •FINAL CABINETRY DESIGN, SIZES AND CONFIGURATION TO BE FINALIZED BY HOMEOWNER AND CABINET MANUFACTURER AND MAY VARY SLIGHTLY FROM DESIGN INTENT SHOWN IN THIS SET OF DRAWINGS. REFER TO CABINETRY SHOP DRAWINGS. ®ALL APPLIANCES TO BE INSTALLED PER MANUFACTURERS INSTRUCTIONS, PROVIDE REQUIRED CLEARANCES AS NECESSARY. ®REFER TO DOOR & WINDOW SCHEDULE ON SHEET A-1.1 FOR KEYNOTE NUMBER. BENCH WITH 4'-0" HOOKS & STORAGE i i REC SED �� ti b b b b b ' II o w 1 SIN o w CAB ET I I�i 2'-9" 2'-7" 3'—B" 4'-6" I. FIELD ELEVATION M LAUNDRY / SHOWER ROOM ELEVATIONS 24"x36" SCALE: 1 /2"=P-0" 11 "x17" SCALE: 1 /4"=1' 0" D Mc DESIGN Darcy J. Mertz Krewson, RDI, aos AIA Ph (425) 610. 8015 Fax (425) 512 0270 PO BOX 12845 Everett, WA 98258 -�oz s iMe� , PROJECT INFORMATION: w w - w 3 N w CD U) = Z � LLJ YQ 06 Lu ti G OCo N ) N W STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 0710112020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 1 CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: INTERIOR ELEVATIONS LAUNDRY & SHOWER ROOM SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-2.4 6._O. (E) CEILING (E) BEAM— (E) CEILING ADJUSTABLE ADJUSTABLE SHELVING &/OR SHELVING &/OR TV SPACE TV SPACE m V 1I N I \II CABINET W/ADJUSTABLE SHELVING &/OR .I 6 TV SPACE M I I I I I I I� CABINET W/ADJUSTABLE SHELVING &/OR TV SPACE CABINETRY 12" MIN 3'-8" (45.257 12" MIN CABINETRY REQUIRED REQUIRED O LTO FAMILY ROOM FIREPLACE ELEVATION - LIVING ROOM (FAMILY ROOM SIMILAR) 24"x36" SCALE: 3/4"=1'-0" 11 "x17" SCALE: 3/8"=1'-0" NOTE: FIREPLACE MANUFACTURERS INSTALLATION REQUIREMENTS: • MANTEL HEIGHT ABOVE BASE OF FIREPLACE (TOP OF HEARTH) MUST BE A MINIMUM OF 42" WITH A MINIMUM DEPTH OF 8" (TO ALLOW HEAT TO DISSIPATE) • MANTEL MUST BE A MINIMUM OF 1" THICK. REFER TO MANUFACTURES INSTALLATION INSTRUCTIONS FOR COMPLETE DETAILS. SEE DETAIL 1 ON SHEET I-3.1. STRUCTURAL NOTE: INFILL SPACE LEFT BY CHIMNEY REMOVAL WITH 2x FRAMING TO MATCH. REFER TO SHEET SS-2. PROPOSED FIREPLACE PLAN 2436 SCALE: 1-1 /2"=1'-0" 1 1 x17 SCALE: 3/4"=1'-0" jDr/i DQSIGN Darcy J. Mertz Krewson, RDI, ass AIA Pk (425) 610. 8015 F- 14251512 0270 PO BOX 12845 Everett, WA 98258 -:o: .., gel°i„ . ).� s ..."1. PROJECT INFORMATION: CL LJ.J L u LJJ i�, —,, N w LEI O = Z 0-) LU pwY Q LL_ _ C Lu ti Z CDQro CI IN ) N w STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVSPERCOMMENTS 07/01/2020 /D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: FIREPLACE DETAILS SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-3.0 EN 0 NOTE: HDR 4x6 DF#2 FOR SPANS OF LESS THAN 6' TYPICAL. R TO SHEET SS-2. CEILING 2 - 12d OR 16d NAILS ® 16" O.C. 1/2" OR 5/8" GWB EACH SIDE (TYPICAL) 2 - 12d OR 16d NAILS ® 16" O.C. WOOD SUB -FLOOR FLOORCOVERING TYPICAL WALL O NOT TO SCALE NEW INDOOR GAS FIREPLACE DOUBLE -SIDED UNIT W/HEAT EXCHANGE.- C Travis Industries Ibs. Kg. 18.25• 413mm TYPICAL DOOR FRAMING O NOT TO SCALE e4• 1828mm aTare• sz4mm 45-1/4" 1lsgmm 2 zsmm NOTE: Thefra marked "SERVICE SIDDE•. 1328mm' dudes the requisite cleamrce to fmmlrD (0.625" 16mm to mead.) 4415HO ST EO TYPICAL WINDOW FRAMING NOT TO SCALE BUILDING SIDING VAPOR BARRIER FLASHING DRIP -CAP WRAPPING TYPICAL EXTERIOR WINDOW FLASHING 0 NOT TO SCALE Installation (for qualified installers only) Fireplace Placement Requirements ❑ Fireplace must be installed on a level surface capable of supporting the fireplace and vent ❑ Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) ❑ Fireplace should be located out of traffic and away from fumiture and draperies. ❑ Fireplace must be placed so the gaps below and above the glass frame do not become blocked. Clearances (a) Clearance to Side of Fireplace 5/8" (16mm). Do not place insulation in this space. NOTE: Drywall (or other combustible) may contact the first %" of the sides of the fireplace. (b) When installed, walls in front of the fireplace must be a minimum 3" (77mm) to the side of the fireplace. Raised Fireplaces ❑ The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace and vent. ❑ The base of the fireplace must be a minimum 64" (1626mm) below the room ceiling. SHEET ROCK BASE MOULDING (E) LOWER FLOOR NOTES: NEW FINAL FINISHED FLOOR TO ALIGN WITH FINISHED FLOOR OF EXISTING - EXACT HEIGHT TO BE VERIFIED IN FIELD. PROVIDE BLOCKING TO FLOOR SUPPORT FRAMING APPROX. EVERY 4' AS NECESSARY. STUD WALL PLYWOOD SUB -STRAIGHT PROVIDE SOLID BLOCKING AT HIGH LOAD AREAS 2x6 OR 2x8 FLOOR SUPPORT FRAMING (FIELD VERIFY) TYPICAL RAISED FLOOR FRAMING NOT TO SCALE NOTE: REFER TO FIREPLACE MANUFACTURER SHOP DRAWINGS & INSTALLATION INSTRUCTION FOR COMPLETE STUD WALL INFORMATION. OBSERVE ALL CLEARANCES AND AREAS TO BE NON-COMBUSTIBLE FRAMING WARNING: Depending upon vent configuration, framing above the fireplace may be placed fiat to the wall (or notched) to allow proper clearances to the vent. Minimum 64"°(1626mm) Fireplace Enclosure Helahl (e4 F�Ocs Rapt S, 1626mm NOTE ON GAS INLET: You may need to notch the framing for the let(see"Gas Line 821328mm1/4" Basin Location" for tletails. 78-7/4"(473mm) TYPICAL FIREPLACE INSTALLATION NOT TO SCALE jDr/i DQSIGN Darcy J. Mertz Krewson, RDI, assoc. AIA Pk (425) 610. 8015 Fox 14251512 0270 PO BOX 12845 Everett, WA 98258 „ m mem. zez , a, 9' /1- 9 PROJECT INFORMATION: CL LJJ L U CL CL uJ ^� 1 �l 0j w .�I O LO = Z 0-) LU pWY Q j�: LL_ _ Cn LUro ti z 2i CD pro a IN , N w STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 �D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 as CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: DETAILS - TYPICAL SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: 1-3.1 ABOVE (TYP IN ABOVE COUNTERTOP I HGFI I I I I � � I LAUNDRY/ SHOWER ROOM I I iII FF RELOCATED WATER HEATER CONNECTION FAMILY ROOM WITHIN SHELVING FOR TV AS • DISP--- J i • ----------------------- KITCHEN I I T � I I I I of I I of UI -� REFRIGERATOR OUTLET g 11 NI I = I ❑I I I I ---� = I L J L- I UNDER COUNTER OUTLET ®ISLAND UNDER-COUN1 REFRIGERATOR (TYP OF 2) OUTLET \\I -ABOVE COUNTERTOP (TYP IN KITCHEN) MICROWAVE OVEN OUTLET WITHIN CABINET C (E) CEILING TO REMAIN ENTRY MASTER BEDROOM DINING AREA o" LIVING o�T°E� ROOM OUTLET TO ALLOW FOR TABLE OR FLOOR LAMPS AT SEATING ABOVE COUNTERTOP I II II II -\ II u ABOVE COUNTERTOP / I / I I1 I ABOVE ------------ MASTER \\�� BATHROOM------------- \� (E) ELEC PANEL i AWIC ACC6SS k STORAGE / \ L / I \ II cFi (E) BEDROOM I FAMILY BATHROOM CEILING TO REMAIN MSU —1• • HP (N) 120 GAL PROPANE TANK, 10' MIN. SETBACK FROM STRUCTURE OR PER REGULATION (VERIFY LOCATION IN FIELD) PERMITS BY CONTRACTOR C( SCHEMATIC ELECTRICAL PLAN NOT TO SCALE LEGEND: @F= ELECTRICAL OUTLET Ew GROUND FAULT INTERRUPTER OUTLET O.C. ON CENTER HP EXTERIOR HEAT PUMP MSU —1 MINI SPLIT WALL MOUNTED UNIT NOTE: isALL CONSTRUCTION SHALL OBSERVE AND COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND CITY, LAWS, REGULATIONS, ORDINANCES, BUILDING CODES, SUBSEQUENT STATE, COUNTY, AND CITY AMENDMENTS TO THE CODES. •GENERAL CONTRACTOR TO CONFIRM FINAL OUTLET LOCATIONS IN THE FIELD AND WITH HOME OWNER. •VERIFY AND TIE INTO EXISTING WIRING AS NECESSARY TO ACCOMMODATE NEW CONFIGURATION. •FINAL LOCATION TO BE VERIFIED IN FIELD. CONTRACTOR TO SECURE ALL NECESSARY PERMITS. D Mc DCSIGN Darcy J. Mertz Krewson, RDI, aos AIA Ph (425) 610. 8015 F­ (425) 512 0270 PO BOX 12845 Everett, WA 98258 iMe� , PROJECT INFORMATION: w W a- CL N w CD 00 U) = Z on ULj LL Y Q Luo ti O Co 0 N LLJ STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN W/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/0V2020 &D ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27t202O DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: SCHEMATIC ELECTRICAL PLAN SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: E-1 a rn m G) GWLv i 54" : ''c4" I h y� r- r•irl F� BEI �'i r.* B C'11 Oran %A I I , y e,-jo, I 1 P J" L Z D(D.vi — r� � —1T F'. F U 'Bud "' S hho� ���t = nr�bltJ�I��►wG .1' 17f :FF FF OD OD P03 Cry 0 0 DM- DQSI(;N Darcy J. Mertz Krewson, RDI, assoc. AIA Ph (425) 610. 8015 Fox (425) 512 0270 PO BOX 12845 Everett, WA 98258 ,. r�reemen� PROJECT INFORMATION: w CL C) w LL LL w CI N w o v) = L or) Q Q Lu r z Ci r� O iV G o N CN w STAMP: RES U 6 Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03126/2020 B REV. LAYOUTS 04/16/2020 C REVS PER COMMENTS 07/01/2020 AD ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09103/2020 Qi I CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: STRUCTURAL BY SIDESWAY ENGINEERING SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: SS-1 CJ m m Z� G'] Z IT! IT! x Z G') N a tD 20 CD Ln Z$ rF Q)L'(Gl gift %%)AW P a Nab- �3�1G CIL 0VT() g-&1LW(k ti k 0 Q 03 n as a 0 0 0 (Vzy-q bP STuP ft/u- NT v/ A35 EA SIDE (? ALL FcAr6s "\ WUNCP.Y/ SHOWER �ODr+f,� FuRR-cvr miew Or 1Nm- it NT GAW o f 2- -o cor flQfL ok Stfwcruemu. �, q�xG PFJ'2- FVu. HT F.vwrIn fl nr SLP�;� =G37 {ny IMY?t:+1 MiH7+1`. I 1 .�_`P+) r r r t f ''�"` Sli;• rr dlPO'dl nl?R-0:T I1irsce 014 AS NIEI�Lry TO ACL.'.TR ouj E PLLPYU G 4 Imo' TD mm 0 "Qf; AKITCHEN kCF �.�Lar[h �C�JA�I wr p1m3 G Cn"Iy^ {+Yv? - +WAIN (T ",- MWE-W +q oast 0"?40G RA') --- 'ES WN L+1P" ARDIQ — Aww m (FYI; — ruRa-alr F.71E*" 7F WdLL AS limm►Fr :[• L��ull{iFoll f Ami _Y n n r faf r9pi lIJ& LAA:o oFF� D k CqW)61. iN 1,?c Fes'' 10G t � � f'—I r Ii0PO4 N ! i � II 1-4 I LIEN rIYP. A9W r-r• I I DINING ARF A I fYiI�G I I 1 _ ROCMTI � j __ If d! (N: Mha+%!; Ott' �9,7YE W: L' SLI7RG Gild � YC• T I � _ v Ns, J C�H 777 , MTMk ! rNl UOCR 21 • 7 ACCm F�1 N �--' 'S Loca. TBr IK XE.- r vExx FRAF[-IY Gast I a­'NNe Tr) .97 '� FUifllw�� rJf!EFII`R M+rlL I+K7"Il115�"-EI'UCE Sr'Jr AR] _FDEP.UYhETFi S 'i1 4AtAIIY-AT+-D 0&4 i_Cos-Tw W1137K 4 m,63 � TC P. mm, iT,P.; 1-0) +V-1 (A_v. FV' FA+GPIFFF I I -I' �Fy{ C--4n n � � &Df Srvb m qx� D F �2 v+u. KT aTw)v WI Nbw. y&)0x_ Ear - StvC, (a ALL f ps �K fist DF PaST DM DESIGN Darcy J. Mertz Krewson, RDI, n.c. AIA PI, (425) 610. 8015 F- 14251512 0270 PO BOX 12845 Everett, WA 98258 9 PROJECT INFORMATION: clL W W 2f ui N w LEI O = w 0-) Y Q C) Lu ti Z i= o0 Qro CI N , N w STAMP: RESUB Oct 20 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEMATIC DESIGN 03/26/2020 REVISIONS: NO. DESCRIPTION DATE A AS -BUILT 03/26/2020 B REV. LAYOUTS 04/16/2020 C REVSPERCOMMENTS 07/01/2020 ENGINEERING ADDED 08/20/2020 E HVAC SCHEMATIC ADDED 09/03/2020 iQ CITY REVIEW COMMENTS 09/27/2020 DRAWN BY: DJMK APPROVED BY: DJMK SHEET TITLE: STRUCTURAL BY SIDESWAY ENGINEERING SCALE: AS NOTED DESIGN DRAWINGS DATE ISSUED: 07/13/2020 SHEET NUMBER: SS-2