APPROVED BLD RESUB 1 BLD2023-0434+Mechanical_Plan+5.4.2023_7.45.51_AM+3524112
i i � � i i i i � COMPRESSOR UNIT LESS THAN 36" TYP E i � . , ,' EL i i ' ,, i i i i i 19' i i i TYP TYP i i Q B � i i 1-HR i �` U1 i p GARAGE 201 Q i�9------------------------------�--------------------------------------------------------------= �_ _' � w 20�3�� i O i O i � i � i i i � WAG 427.4 i i 208/240 V 40 AMP i ELECTRICAL VEHICLE CHARGING i i i i i i i i � p i i , i i _ i N �----------------------------------------------------------------221�1-------------------------------- i --, i i i i i 1-HR i U10 o GARAGE 301 i � TYP TYP i C9----------------------------------- w ---------------- Q B i > • i O o i � 11' 52'6" 17'6" 7' 2'4" 2'3" 2'S" THRESHOLD PER IBC 1104; ICC A117.1-09, 402 1/2 BEVELED NO STEEPER THEN 1:2 <9 LO �------------ �9-MINiW/SELF � CLOSING HINGE & SMOY�E GASKET 4' � 2" I � 114 N `-� X � L ® 3068 X • � �� 2020 2020 it COMPRESSOR UNIT � � N � N �� LE85 THAN 36" O=-------------- X � N 90 MIN W/ SELF ----- -----------------_ _--- " " � � ' CLOSING HINGE _ _ _ _ - `� � - N -- -- � L � �' � - , __--- _ _ - i T3-1/2" 2'7-1/2' 4' - -- " � � WAC 427.4 i �1 208/240 V 40 AMP 1 HR MACHINE RM ELECTRICAL VEHICLE CHARGING 45 MIN W/ SELF � t\ � CLOSING HINGE � &SMOKE GASKET � _ N i � UNHEATED AREA ELECTRIC C�9 ---'" -� � - - O N HEAT 40 MIN. TEMP 1 WATT � PER SQ. FT. MAX _, - - - i - �i 1-H�----- AMBIENT AIR TEMPERATURE AND = '�, _—� � i HUMIDITY IN THE MACHINE ROOM - � =�, _---'� � T T"� � TO BE REGULATED VIA 50 CFM FAN � -'" LJ 1 � PER MFG RECOMMENTATION ��,; ""� �� GARAGE 202 i TYP TYP � �� �i F _•�_ .�'��• '�0 MIN W/ SELF♦— � CLOSING HINGE � &SMOKE GASKET ; � 7'5" p •� • ♦ i ��.���� ' AF I. I. I� it © � WAC 427.4 � 208/240 V 40 AMP � ELECTRICAL VEHICLE CHARGING i i i i i i i i i i - - - ---, N � � i i � i m i � i fi1'�� G �. 2020 2020 � 7'1 " 2'3" 12'4" 28' CV CV N N <9 STAIR CARPET i N � i �O N i � __ i � _ - - � 90 IN UU/ SELF - � � CLO ING, HINGE _ - � � i � � IN W/ ELF _ - � � � � ING HI GE TYP p� _ -_ -- �- � P i UKE G SKE � _ __ - J i T - _ -- 2� .� 1 WAG-427.4 - - N � � _ _ 208/240V 40 AMP � ELECTRICAL VEHICLE CHARGING co � � CV W TYP TYP O Q B '�, . _. HR EXIT H ��, -� P SSAGEWAY ' • �` �, 1-HR `� 90 IN W/ SELF � � CLO ING HINGE U1 o GARAGE 302 i N i _— �_ � 6� i �T - 60 MIN W/ SELF '�, NG CLOSING CV '- " " H NGE N & SM E GAS ET � � 3068 5'1/2" 10'9-1/2" 14'8 1/2�" T RESHOLD i PER IBC 1104; � SPRINKLER i ICC A117. -09, 402 RM i 1/2" BE ELED NO STEEPER THEN 1:2 COMPRESSOR UNIT �----- ----- -�ESSTHAN36" i 3068 � 2 5 �� � �� 111 � �� 6 7 � �� 2 3-1/2 � �� 14 8-1/2 � 25'6" 90 I CL SIN 61'9" SIGN ON DOOR "FIRE SYSTEM CONTROL" i i �_ i � � i � �I s Zone Corner Flag Setbacks: Required Actual Front Sides Rear Other Height � 2X6 @ 16" O.G. STUD WALL W/ R-21 INSUL. ® (2)2X4 @ 16" O.C.,1" AIR SPACE � 1 HR METAL STUD WALL (AFTER ELEV. INSTALL) 0 2X4 @ 16" O.C. � 2X6 @ 16" O.G. � WOOD COLUMN OA PROVIDE OUTSIDE AIR FOR FURN. &WATER HEATER (RELIEF MUST VENT TO OUTSIDE (NOT GARAGE) i`�,'i 22"X30" ATTIC ACCESS (30" MIN. VERT. CLEARANCE � �� � WEATHERSTRIP & INSUL. TO R-49 V_ _J � "NO EXIT' SIGN O 120V SMK DET W/BATT BACKUP (INTERCONNECTED) ■ FIRE DETECTOR INTERCONNECTED EMERGENCY LIGHTING W/BATT BACKUP '■�' INDICATES ILLUMINATED EXIT SIGNS Wl BATT BACKUP GONTORL JOINTS BARRIER FREE DIRECTIONAL SIGNAGE LOCATION FUTURE GRAB BARS: PROVIDE BLOCKING ® HORIZONTAL CENTERLINE POSTION = 35" FROM FLOOR PER ICC/ANSI 609.4 CARBON MONOXIDE DETECTOR PER IRC 315 ALL UNITS ARE TO BE TYf E "B" UNITIS f ER ICC-AN51 A117-1 SECTION 1004. INSTALL SOLID 2X BLOCKING FOR FURTURE GRAB BARS IN ALL BATHROOMS CLEAR FLOORS AREAS ARE INDICATED IN THE TYf E "B" BATHROOMS AND KITCHEN CERTIFICATE WILL BE POSTED IN FURNACE (OR OTHER APPROVED AREA) WITH THE FOLLOWING INFORMATION: R-VLAUNES, U-VALUES,RESULTS FROM DUCT SYSTEM TEST AIR LEAKAGE TESTING, RESULTS FROM BUIDLING ENCELOPE AIR LEAKAGE TESTING, TYPES AND EFFICIENCIES OF HEATING, COOLING ,AND SERVICE WATER HEATING EQUIPMENT PER R401.3 DUCTS ARE REQUIRED TO BE INSULATED TO A MINIMUM OF R-8 PER R403.3.1 THE DWELLING 15 REQUIRED TO BE TESTED &VERIFIED A5 HAVING AN AIR LEAKAGE RATE NOT EXCEEDING 3 AIR CHANGES PER HOUR PER R402.4.1 MECHANICAL DUCTS ARE REQUIRED TO BE SEAL TESTED IN ACCORDANCE WITH 403.3.2 TESTING TO COMPLY WITH WSU R5-33. EXTERIOR HEADERS ARE REQUIRED TO BE INSULATED WITH A MIN. OF R-10 INSULATION. CORNERS OF STUD WALLS ARE REQUIRED TO BE FULLY INSULATED. MECHANICAL SYSTEM PIPING ISOLATED MIN. R-6 PER R403.4 APPROVED BY PLANNING L s;�oea �y 'This plan sheet has been approved for the Mechanical permit only. Any other notes or 'details found on this plan sheet to be referred t the approved Building permit plan set. ■ City Of Edmonds Building Department Work MECHANICAL Address 554 PARADISE LN -------------------------------------------------------- Owner PARADISE HEIGHTS- BLDG C ---------------------------------------------------- Approved Date 5/10/2023 -------------------- Building Official l7 w. Permit Number BLD2023-0434 DATE REV1 REV2 REV3 REV4 REV5 REVISIONS PAGES CHANGES N ELEVATOR EQUIPMENT ROOM •135° HEAT DETECTOR @SPRINKLER HEADS •PROVIDE FRESH AIR THROUGH 4" DUCT •EXAUST FAN TO MAINTAIN A MAX. TEMP. OF 90° & VENT TO OUTSIDE AS REO'D BY MFG SPECS ELEVATOR NOTES •UNHEATED SPACE•CONTINOUS RIM @FLOORS. •INSTALLATION OF ADDITIONAL ELEVATOR DOORS SHALL NOT VIOLATE LISTINGS OF ELEVATOR (TYP) MECHANICAL CHASES •CONTINUOUS RIM @FLOOR. SPRINKLER ROOM •FIRE ALARM CONROL PANEL IN SPRINKLER ROOM W/ CENTRAL STATION SERVICE MONITORING •ANNUNCIATOR IN LOBBY STAIR NOTES •MAINTAIN REQ'D 1 HR STAIRS ENCLOUSURES &MIN 6'-8" HEADROOM @STAIRS •ELECTRIC HEAT 40 MIN.TEMP 1 WATT PER SQ. FT UNHEATED SPACE •STAIR BACKING FOR HAND RAIL •CONTINUOUS RIM @FLOOR. •BASEMENT STAIR: RISE = 6.81" RUN = 11" ALL OTHER STAIRS: RISE = 6.72" FIREPLACE NOTES •'D' CLEARANCE FIREPLACE W/ DIRECT VENT FACTORY BUILT FIREPLCE SHALL BE INSTALLED PER MANUFACTURER'S SPECS AND SHALL HAVE APPROAL LABEL ATTACHED 5/8" TYPE "X" GWB TO ROOF SHEATING FIREPLACES &STOVES MUST BE D.O.E CERTIFIED &LABELED AS SUITABLE FOR USE DURING A FIRST STAGE BURN BAN. IBC PROVIDE ONE OPENABLE ESCAPE WINDOW IN BASEMENT & IN EACH SLEEPING ROOM MEETING ALL THE FOLLOWING REQUIREMENTS: 1. AN OPENABLE AREA OF NOT LESS THEN 5.7 SO.FT. 2. A MIN. CLEAR HEIGHT OF 24" 3. A MIN. CLEAR WIDTH OF 20" 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FINISH FLOOR. 5. ALL WINDOWS TO INCLUDE FRESH AIR VENTS OR METERED FRESH AIR SUPPLY @FURNACE 6.ALL WINDOWS &DOORS HAVING ACCESS TO EXTERIOR OR UNHEATED TO BE SEALED PER SEC. 402.4.1.1(WAC) • RECESSED LIGHTING TO BE IC RATED • ALL TYPE "B" DECK SURFACES TO BE NO MORE THAN 4" BELOW INTERIOR FLOOR LEVEL •ALL TYPE "B" FRONT DOORS TO BE 2'-10" MIN. &ALL DOOR THRESHOLDS CANNOT EXCEED 1/2" PER 404 •ALL DWELLINGS MUST BE TYPE B ,OPT. B •ALL REQUIRED DOOR HARDWARE TO MEET IBC CHAPTER 11 & EXITING PER 1010.1.9.1 IMC TYPE B OR L VENT CONNECTORS REO'D ON FUEL -BURNING APPLIANCE IN UNHEATED SPACES HYDRONIC HEATING SYSTEM APPROVAL BY THE WATER SURVEYOR DOES NOT RELIEVE THE CUSTOMER OF THE RESPONSIBLITY TO COMPLY W/ THE REQUIREMENTS OF OTHER AGENCIES HAVING JURISDICTION. APPROVAL OF THIS PLAN DOES NOT VEST THE BUILDING OR PLUMBING SINGE FUTURE CHANGES IN THE CUSTOMERS WATER USE MAY INCREASE THE ASSESSMENT RISK &THE SURVEYORS PROTECTION REQUIREMENTS. IMC. CHAPTER 12 BUILDING INSPECTORS MUST OBSERVE A HYDROSTATIC TEST ON THE HOT WATER SUPPLY LINES &THE PANEL SYSTEM. •TEST:100 PSI WATER PRESSURE OR 1-1/2 TIMES THE OPERATING PRESSURE, WHICHEVER IS GREATER. MIN 30 MINUTES TEST. •PIPING EMBEDDED IN CONCRETE MUST BE PRESSURE TESTED PRIOR TO POURING OF CONCRETE AND BE MAINTAINED DURING PLACEMENT. • GARAGE HEADROOM TO BE MIN. OF 7'-0" CLEARANCE FROM ALL PIPES, SPRINKLER HEADS, DUCTS, BEAMS, & INSULATION, ETC. •MIN. HEADROOM CLEARANCE OF 7'-6" IS REO'D IN ALL HABITAL SPACES, & 7'-0" IS REO'D ELSEWHERE •LOCATION OF EMERGENCY LIGHTING SHALL BE APPROVED BY FIRE MARSHAL •REQ'D WHEEL STOP @ALL PARKING STALLS •EXHAUST OUTLETS TO BE A MIN. OF 3'-0" FROM BUILDING OPENINGS & 10'-0" FROM SUPPLY AIR INLETS (TYP). •DOUBLE GHEGK VALVE INSPECTION REQ'D BY CITY GROSS CONNECTION CONTROL SPECIALIST PRIOR TO HYDRO STATIC TEST OF FIRE SPRINKLER SYSTEM. • ACCESS TO DOUBLE CHECK VALVE MUST BE WITHIN 5' ABOVE FINISHED FLOOR OR A 30"X30" MIN PLATFORM � MUST BE INSTALLED FOR ACCESS •WALLS SEPARATING DWELLING UNITS FROM COMMON AREAS (STAIR ENCLOSURES, ELEVATOR SHAFT, ETC) MUST HAVE AN STC OF 50 OR MORE •SMOKE &DRAFT -ASSEMBLIES IN LOBBY,1-HR AREAS & p ELEVATORS/ ENTRY LOCATIONS SHALL HAVE A FIRE PROTECTION RATING OF NOT LESS THAN 50 MIN. &BEAR AN APPROVED LABEL IDENTIFING THE RATING OF THE ASSEMBLY FOLLOWED BY THE LETTER "S". DOORS SHALL BE MAINTAINED SELF -CLOSING OR BE AUTOMATIC CLOSING BY ACTIVATION OF A SMOKE DETECTOR ADDITIONAL PLUMBING REQUIREMENTS: •MAIN BUILDING SHUT-OFF REO'D ON WATER SUPPLY LINE. •PRESSURE REDUCTION VALVE ON MAIN WATER SUPPLY LINE REO'D BY CITY CODE •EXPANSION TANK REQ'D ON EACH HOT WATER TANK. •VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO THE OUTSIDE •HOT WATER HEATER MUST BE SEISMICALLY ANCHORED OR STRAPPED @POINTS WITHIN THE UPPER 1/3 &LOWER 1/3 OF ITS VERTICAL DIMENSION. @THE LOWER POINT, A MIN. DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS W/ THE STRAPPING •PROIVIDE INDIVIDUAL SHUTOFFS FOR EACH UNIT •1" AIRGAP REQ'D ON DISHWAHSHER •ALL SHOWERS HEADS TO BE EQUIPPED WITH FLOW CONTROL DEVICE TO LIMIT FLOW T01.75 GPM •AIR SWITCH FOR DISPOSAL IN SINK •ALL HOTWATER PIPES MUST BE INSULATED WITH R-3 INSULATION PER 2015 WSEC SEC 403.5.3. SCALE: 1 / 4" =1'-0" GARAGE 201: 855.74 Q.FT. GARAGE 202: 501.02 SQ. FT. GARAGE 301: 647.97 SQ. FT. GARAGE 302: 530.89 SQ. FT. COMMON AREA: 678.45 SQ.FT. TOTAL 2,581.85 SQ. FT. RESUB May 04 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �S V � � N � o u M w� Cl� .o v , Ww Q 3 � o z° W �' I --I a AN �-7 V • � I� o W o 0 � � O�� � Q U�z O�Q �o �W ................ REVISIONS: 7.21.20 10.16.20 2.6.23 5.2.23 5.2.23 to N to N - - CV �' N 0 (V N O 13' � T 15'6" 4'6" 11' ., 3'2" 4'7" 4'7" 2'9" 2'9" 2'9" 2'9" m i DECK ELASTOMERIG �p0 � �� N � N ���n ���n V C9 CV � 3'11" U �' B O N � DEN UNIT 201 LpV � ° 0 1-HOUR FLOOR/CEILING OCCUPANCY o SEPARATION REQ'D ABOVE N WSEC CREDIT 5a (.5 credits) TRITON BOWE BY KOHLER (FAUCET) -800T70-4AKL-CP 1.0 GPM OPTION #1: INTERMITTENT WHOLE HOUSE VENTILATION 17' 4'7" 4'7" 3'11" DECK ELASTOMERIC GAS STUB N pj K) , 7'6" 4'6" 3' 1'6" 2'6" 1'1" 5' 7' ALL HABITABLE ROOMS WILL REQU RE OUTDOOR AIR3NLET5 (�j UNIT 2 0 2 DIN �"_11-" RUNTIME FACTOR2=50%RUN TIMEIN EACH 4-HOUR SEGMENT. N 1-HOUR FLOOR/ FILING OCCUPANCY CAI�RET � I I � o� ; DUCTLESS INDOOR � SEPARATIO REQ'D ABOVE � w i KIT o Z .� UNIT LOCATION WSEC CREDIT5a (.5 credits) ------- --- c - � J.-� -�� o � X I o • � 97 3 2 LIV - TRITON BOWE BY KOHLER (FAUCET) N K-800T70-4AKL-CP 1.0 GPM I .SD (n � � � � � I 3.12.4 �. -. ..� � � CAPRET � \ TYP "A" KITCHEN PER � TYP "B" KITCHEN PER KIT � �� CLEAR ICC 1003.12 � � LT � � I 1 4.1 HARDWOOD � SPACE � CLEAR I - 170 CFM WHOLE.I�Q�LQ,' - 8' 4' DW I � HOUSE FAN � � IS) TYP �9 I 4'11" 2'1" - � � � i I SPACE � � � ,' � � uro. � ac A - - _ - - - - - � � o O O � �• J..-• � ' • N DUCTLESS INDOOR I � � '_________ __ ______ ______ .v UNIT LOCATION \`\ I N I � �„_„_„_„_„� % CLEAR I. � _. I - - = 3068 4' '3" 4 - - � K� � � � WS C CREDIT 5c (1.5 credit) � � HE T PUMP HOTWATER TANK _ _ - J BED # 2 N � � J � CAPRET � ENTRY Q TILE - � I CLEAR II � �. � SPACE ENTRY CLOSET �- � �' ' I SPACE -------------------------------------------- ' � � ' - I � / 5068 � - - <9------------ ------ ----- �-------------------- ----- - - -- --CFM----------------------------' 3'7" 3'6-1/ 4' N ! 5'9-1/ cal T.O. 12'4-1/2" 50CFM ___ _____ ENTRY • V.T.O. E TILE � ELECTRIC IN WALL HEATER 1 00.22 ft '9-1/2" 5'1" N � • � N _ - . ' ., � � BATH TYf `� N � - TILE 0 p - _ I � ♦� ♦♦N � � ELECTRIC IN WALL HEATER (j C� N I ♦ � N i � � WSEC REDIT 5c (1.5 credit) HEAT PUMP HO ER TANK � � � �t = � 60 MIN. WITH SELF O � '5-1/2" � 2'3" ; CLOSING HINGE cq � BED # 2 � `♦ ,ram _ � � CAPRET J �0 N - ♦ ♦ �.. N N � O Lp CV ♦ ♦ t'n N - - - � � ,' � � ', I I �N � REMOVABLE VANITY � _ � I W I � = NO CAB. UNDER SINK � � � ELECTRIC IN WALL HEATER ..-.. ..-..-.. lid - N = J BED # 3 I � � - �. �o cFM` � CAPRET N � � 14 \ � Q WSEC CREDIT 5a (.5 credits) � � �. GROHE 2611700 FAIRBORN SHOWER HEAD 1.75 GPM � � I r - - PARALLEL;' I-..Lp,P�O,,c,E�1 � IFLOORS.PACEI TRITON BOWE 13Y KOHLER (FAUCET) K-SOOT70-4AKL-GP 1.0 GPM �,_ D I ° � � AT o I ' -1/2" 2' " 8'4" '31/2" 2' � � AVARTORY -1/2" j N 3068 3068 � � -- � I NO CAB. UNDER SINK W.I.C. I ALLOWING FOR A - i FORWARD APPROACH I N � I I o H• � W.I.C. � CAPRET (�j � I I I I � I I i I I 'MBED � I I CAPRET - I I I I (i7 Q Ci7 U I I I I � � I 2468 P D. I �z � � - - N MBA' O N TILE �' 44" MAX 51LL HEI HT � 0 4 4 5050 SLIDER I 7 7 6 1' 5' 1 1 ' TYPE "B" ' BATHROOM PER ICC 1004.11.3 ONE BATHING FACILITY THAT IS ON AN ACCE551BLE ROUTE 15 REQUIRED TO COMFY WITH OPTION "B" PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS WATER CLOSET, LAVATORY, AND BATHTUB U � � � N = ALLOWING FORA � 1�0 CFM Hb�•E••-••�.• • � N N � FORWARD APPROACH I IHouSE �''�_1/2" � 0 � � 3'2-1/2" � 8'5-1/2" 4'6" I I � U.T.O. - N I . I, � I r � _ ,I I U I � 3068 � � N I I ', ' ', L_.._.._.I � -----CV ------ _ -. .. N DUCTLE55 INDOOR � cal J =. }.. Q I �Q��.� o I J � H � I ���` = o Z ¢ > I � N ST R CAPRET � UNIT LOCATION N o l � � � �_J I p IC y �. [`C� � OPTION #1: INTERMITTENT WHOLE HOUSE VENTILATION U51NG EXHAUST FANS &FRESH AIR INLETS. IMC 403.8.E z • .� v RUN T MBET FACTOR 02M 50°°/LRUN TIME INO EAC �4--HOUR SEGMENT /A� Q Bl �.'r�„-„-„ c° 1 � ILE � � 3068 50 CFM 'X4' SHOW � � VTO 50 CFM V.T.O. 2468 PD. 1/2" 11'8"� I N �; W N � � � - O N ' 4' SH W N `� , I MBED �_ CAPRET � / \ i I1 44" MAX SILL HEIGHT I I I I I I I I I I I ----------- -----------I 6' 1'8-1/2' 4'3-1/2" 6'6" '6" 8' 2' 6' 1 10' 68' WSEC CREDIT 5a (.5 credits) TYPE "B" GROHE 2611700 FAIRBORN BATHROOM PER ICC 1004.11.3 SHOWER HEAD 1.75 GPM ONE BATHING FACILITY THAT TRITON BOWE BY KOHLER (FAUCET) IS ON AN ACCESSIBLE ROUTE K-SOOT70-4AKL-GP 1.0 GPM 15 REQUIRED TO COMFY WITH OPTION "B" PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS WATER CLOSET, LAVATORY, AND BATHTUB 7' N o� Z�` <9 � 2X6 @ 16" O.G. STUD WALL W/ R-21 INSUL. ® (2)2X4 @ 16" O.C.,1" AIR SPACE � 1 HR METAL STUD WALL (AFTER ELEV. INSTALL) 0 2X4 @ 16" O.C. � 2X6 @ 16" O.G. � WOOD COLUMN OA PROVIDE OUTSIDE AIR FOR FURN. &WATER HEATER (RELIEF MUST VENT TO OUTSIDE (NOT GARAGE) I`�,'I 22"X30" ATTIC ACCESS (30" MIN. VERT. CLEARANCE I �� I WEATHERSTRIP & INSUL. TO R-49 V_ _J � "NO EXIT' SIGN O 120V SMK DET W/BATT BACKUP (INTERCONNECTED) ■ FIRE DETECTOR INTERCONNECTED EMERGENCY LIGHTING W/BATT BACKUP '■�' INDICATES ILLUMINATED EXIT SIGNS Wl BATT BACKUP GONTORL JOINTS BARRIER FREE DIRECTIONAL SIGNAGE LOCATION FUTURE GRAB BARS: PROVIDE BLOCKING ® HORIZONTAL CENTERLINE POSTION = 35" FROM FLOOR PER ICC/ANSI 609.4 CARBON MONOXIDE DETECTOR PER IRC 315 ALL UNITS ARE TO BE TYPE "B" UNITIS PER ICC-AN51 A117-1 SECTION 1004. INSTALL 50LID 2X BLOCKING FOR FURTURE GRAB BARS IN ALL BATHROOMS CLEAR FLOORS AREAS ARE INDICATED IN THE TYPE "B" BATHROOMS AND KITCHEN CERTIFICATE WILL BE P05TED IN FURNACE (OR OTHER APPROVED AREA) WITH THE FOLLOWING INFORMATION: R-VLAUNES, U-VALUES,RESULTS FROM DUCT SYSTEM TEST AIR LEAKAGE TESTING, RESULTS FROM BUIDLING ENCELOPE AIR LEAKAGE TESTING, TYPES AND EFFICIENCIES OF HEATING, COOLING ,AND SERVICE WATER HEATING EQUIPMENT PER R401.3 DUCTS ARE REQUIRED TO BE INSULATED TO A MINIMUM OF R-8 PER R403.3.1 THE DWELLING 15 REQUIRED TO BE TESTED &VERIFIED A5 HAVING AN AIR LEAKAGE RATE NOT EXCEEDING 3 AIR CHANGES PER HOUR PER R402.4.1 MECHANICAL DUCTS ARE REQUIRED TO BE SEAL TESTED IN ACCORDANCE WITH 403.3.2 TESTING TO COMPLY WITH WSU R5-33. EXTERIOR HEADERS ARE REQUIRED TO BE INSULATED WITH A MIN. OF R-10 INSULATION. CORNERS OF STUD WALLS ARE REQUIRED TO BE FULLY INSULATED. MECHANICAL SYSTEM PIPING ISOLATED MIN. R-6 PER R403.4 'This plan sheet has been approved for the Mechanical permit only. Any other notes or 'details found on this plan sheet to be referred to the approved Building permit plan set. ■ I ■ M H i �� N ELEVATOR EQUIPMENT ROOM •135° HEAT DETECTOR @SPRINKLER HEADS •PROVIDE FRESH AIR THROUGH 4" DUCT •EXAUST FAN TO MAINTAIN A MAX. TEMP. OF 90° & VENT TO OUTSIDE AS REO'D BY MFG SPECS ELEVATOR NOTES •UNHEATED SPACE•CONTINOUS RIM @FLOORS. •INSTALLATION OF ADDITIONAL ELEVATOR DOORS SHALL NOT VIOLATE LISTINGS OF ELEVATOR (TYP) MECHANICAL CHASES •CONTINUOUS RIM @FLOOR. SPRINKLER ROOM •FIRE ALARM CONROL PANEL IN SPRINKLER ROOM W/ CENTRAL STATION SERVICE MONITORING •ANNUNCIATOR IN LOBBY STAIR NOTES •MAINTAIN REO'D 1 HR STAIRS ENCLOUSURES &MIN 6'-8" HEADROOM @STAIRS •ELECTRIC HEAT 40 MIN.TEMP 1 WATT PER 50. FT UNHEATED SPACE •STAIR BACKING FOR HAND RAIL •CONTINUOUS RIM @FLOOR. •BASEMENT STAIR: RISE = 6.81" RUN = 11" ALL OTHER STAIRS: RISE = 6.72" FIREPLACE NOTES •'D' CLEARANCE FIREPLACE W/ DIRECT VENT FACTORY BUILT FIREPLCE SHALL BE INSTALLED PER MANUFACTURER'S SPECS AND SHALL HAVE APPROAL LABEL ATTACHED 5/8" TYPE "X" GWB TO ROOF SHEATING FIREPLACES &STOVES MUST BE D.O.E CERTIFIED &LABELED AS SUITABLE FOR USE DURING A FIRST STAGE BURN BAN. IBC PROVIDE ONE OPENABLE ESCAPE WINDOW IN BASEMENT & IN EACH SLEEPING ROOM MEETING ALL THE FOLLOWING REQUIREMENTS: 1. AN OPENABLE AREA OF NOT LESS THEN 5.7 SQ.FT. 2. A MIN. CLEAR HEIGHT OF 24" 3. A MIN. CLEAR WIDTH OF 20" 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FINISH FLOOR. 5. ALL WINDOWS TO INCLUDE FRESH AIR VENTS OR METERED FRESH AIR SUPPLY @FURNACE 6.ALL WINDOWS &DOORS HAVING ACCESS TO EXTERIOR OR UNHEATED TO BE SEALED PER SEC. 402.4.1.1(WAC) • RECESSED LIGHTING TO BE IC RATED • ALL TYPE "B" DECK SURFACES TO BE NO MORE THAN 4" BELOW INTERIOR FLOOR LEVEL •ALL TYPE "B" FRONT DOORS TO BE 2'-10" MIN. &ALL DOOR THRESHOLDS CANNOT EXCEED 1/2" PER 404 •ALL DWELLINGS MUST BE TYPE B ,OPT. B •ALL REQUIRED DOOR HARDWARE TO MEET IBC CHAPTER 11 & EXITING PER 1010.1.9.1 IMC TYPE B OR L VENT CONNECTORS REQ'D ON FUEL -BURNING APPLIANCE IN UNHEATED SPACES HYDRONIC HEATING SYSTEM APPROVAL BY THE WATER SURVEYOR DOES NOT RELIEVE THE CUSTOMER OF THE RESPONSIBLITY TO COMPLY W/ THE REQUIREMENTS OF OTHER AGENCIES HAVING JURISDICTION. APPROVAL OF TH15 PLAN DOES NOT VEST THE BUILDING OR PLUMBING SINCE FUTURE CHANGES IN THE CUSTOMERS WATER USE MAY INCREASE THE ASSE55MENT RISK &THE SURVEYORS PROTECTION REQUIREMENTS. IMC. CHAPTER 12 BUILDING INSPECTORS MUST OBSERVE A HYDROSTATIC TEST ON THE HOT WATER SUPPLY LINES &THE PANEL SYSTEM. •TEST:100 PSI WATER PRESSURE OR 1-1/2 TIMES THE OPERATING PRESSURE, WHICHEVER IS GREATER. MIN 30 MINUTES TEST. •PIPING EMBEDDED IN CONCRETE MUST BE PRESSURE TESTED PRIOR TO POURING OF CONCRETE AND BE MAINTAINED DURING PLACEMENT. • GARAGE HEADROOM TO BE MIN. OF 7'-0" CLEARANCE FROM ALL PIPES, SPRINKLER HEADS, DUCTS, BEAMS, & INSULATION, ETC. •MIN. HEADROOM CLEARANCE OF 7'-6" IS REQ'D IN ALL HABITAL SPACES, & 7'-0" IS REQ'D ELSEWHERE •LOCATION OF EMERGENCY LIGHTING SHALL BE APPROVED BY FIRE MARSHAL •REQ'D WHEEL STOP @ALL PARKING STALLS •EXHAUST OUTLETS TO BE A MIN. OF 3'-0" FROM BUILDING OPENINGS & 10'-0" FROM SUPPLY AIR INLETS (TYP). •DOUBLE GHEGK VALVE INSPECTION REQ'D BY CITY GROSS CONNECTION CONTROL SPECIALIST PRIOR TO HYDRO STATIC TEST OF FIRE SPRINKLER SYSTEM. • ACCESS TO DOUBLE CHECK VALVE MUST BE WITHIN 5' ABOVE FINISHED FLOOR OR A 30"X30" MIN PLATFORM MUST BE INSTALLED FOR ACCESS •WALLS SEPARATING DWELLING UNITS FROM COMMON AREAS (STAIR ENCLOSURES, ELEVATOR SHAFT, ETC) MUST HAVE AN STC OF 50 OR MORE •SMOKE &DRAFT -ASSEMBLIES IN LOBBY,1-HR AREAS & ELEVATORS/ ENTRY LOCATIONS SHALL HAVE A FIRE PROTECTION RATING OF NOT LESS THAN 50 MIN. &BEAR AN APPROVED LABEL IDENTIFING THE RATING OF THE ASSEMBLY FOLLOWED BY THE LETTER "S". DOORS SHALL BE MAINTAINED SELF -CLOSING OR BE AUTOMATIC CLOSING BY ACTIVATION OF A SMOKE DETECTOR ADDITIONAL PLUMBING REQUIREMENTS: •MAIN BUILDING SHUT-OFF REO'D ON WATER SUPPLY LINE. •PRESSURE REDUCTION VALVE ON MAIN WATER SUPPLY LINE REO'D BY CITY CODE •EXPANSION TANK REQ'D ON EACH HOT WATER TANK. •VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO THE OUTSIDE •HOT WATER HEATER MUST BE SEISMICALLY ANCHORED OR STRAPPED @POINTS WITHIN THE UPPER 1/3 &LOWER 1/3 OF ITS VERTICAL DIMENSION. @THE LOWER POINT, A MIN. DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS W/ THE STRAPPING •PROIVIDE INDIVIDUAL SHUTOFFS FOR EACH UNIT •1" AIRGAP REQ'D ON DISHWAHSHER •ALL SHOWERS HEADS TO BE EQUIPPED WITH FLOW CONTROL DEVICE TO LIMIT FLOW T01.75 GPM •AIR SWITCH FOR DISPOSAL IN SINK •ALL HOTWATER PIPES MUST BE INSULATED WITH R-3 INSULATION PER 2015 WSEC SEC 403.5.3. SCALE: 1 / 4" =1'-0" 201: LIV=1,800.75 SQ. FT. DECK=175.88 SQ. FT. 202: LIV=1,456.32 SQ. FT. DECK=114.25 SQ. FT. COMMON AREA: 206.55 SQ. FT. TOTAL = 3,463.62 SQ. FT. r� z V � � N a F-I w CA ,o v , Ww Q 3 � o z° � � A ,� N �-7 V •� ,� o W o 0 � � O�� Q Q v�o O�Q �W ................ REVISIONS: 7.21.20 10.16.20 2.6.23 5.2.23 1 5.2.23 1 10' 11' 1' 15'6" 4'6" 11' .� 3�2�� 4���� 4���� 2�9�� 2�9�� 2�9�� 2�9�� ---- ---- ----- ------ ----- ----,I O I I I I I _ __ _____ ___DECK ELASTOMEI�IG_---__,' I , � I N I � I V � I - N cal II 1T ��6�� 4�6�� 3' 1�6�� � _ I � I � � - I � 3„�1�� 4���� 4���� 3'11" 3�9�� 3�9�� � I R � ------------------- -�� B I III DECK III �` N I DIN UNIT 301 LIV � � ___ �LASTo�rE�z�c_ __________ ____ �, I CAPRET GAPRET ` GAS STUB N 1-HOUR FLOOR/CEILING OCCUPANCY SEPARATION REQ'D ABOVE � � � � II WSEC CREDIT 5a (.5 credits) - V TRITON BOWE BY KOHLER (FAUCET) N B R I I K-8OOT7O-4'AKL-CP 1.O GPM OPTION #1: INTERMITTENT WHOLE HOUSE VENTILATION � , � I I USING EXHAUST FANS &FRESH AIR INLETS. IMC 403.8.E � � � � � 0 � , N _ I 2'1" 4'6" 6'6" ALL HABITABLE ROOMS WILL REQUIRE OUTDOOR AIR INLETS N ['C� I RUN TIME FACTOR 2 = 50% RUN TIME IN EACH 4-HOUR SEGMENT. F N I 1-HOUR FLOOR/CEILI G OCCUPANCY I ' �"-"-"� N SEPARATION R Q'D ABOVE CAPRET I II I I DUCTLESS INDOOR � I N - _ = UNIT LOCATION WSEC CREDIt 5a (.5 credits) I ; I � Q v I � gl�l� 3�211 � LIV TRITON BOWE BY KOHLER (FAUCET) I � = K-800T70-4AKL-CP 1.0 GPM I_ _ _ _ _ _ I I W �.. � TYP "B" KITCHEN PER _ N I II O � � � � ICC 1004.12 r.,-„-,•� 0 � CAPRET I � TYP "B" KITCHEN PER KIT I I � I,.„_„_,� \ � I � � 4. HARDWOOD I 0 �W � I I �„ I„_„_„_„� : U � � I _ �' 170 CFM WHOLE I 'Q _ I 8 4 N I \ � ,CLEAR � � � I HOUSE FAN � � � � I , „ , „ I _ I - -I `� I_ .i SPACE � � � ,' ; - V.to. I QL I � A � � o � I 411 21 I � - -I I \ � �". � Lam..-..-.� � N O I / / � I � I � � DUCTLESS INDOOR � I I _______ CFM �v I UNIT LOCATION � \ II •0• � - � � CLEAR II I. _ I � � I CLEAR � �. SPACE .. .. I � --I � j I ENTRY CLOSET SPACE � \ � I I _ �� � I - - - ! 3068 � - I � / � ------------------------------------------- I � 4' �3�� 4 _ - 5068 � I �_�,_„_,�_„_,. � �" i - II � I � = I I � � � - <9 ______ ____________ _ _C_F_M----------I I ' W EC CREDIT 5c (1.5 credit) 3'7" 3'6-1/ ' 4' N 5'9-1/ " cN TYP I � I � IlO HAT PUMP�HOTWATER TANK EL TOR r.o. I � E N I = - i �i I � J BED # 2 N � � 12 4-1/2 I � 50 CFM I CV X CAPRET � N � � ENTRY � �T.o. ° WSEC CREDIT 5a .5 credits � � TILE - TRITON BOWE BY KOHLER (FAUCET)) I ELECTRIC IN WALL HEATER C9 <0 I cV K-800T70-4AKL-CP 1.0 GPM I o _ - �, � _,� _ � � BATH I � � N N � � • ' � TILE 42• GROHE 2611700 FAIRBORN I I O O _ � � �� �, N SHOWER HEAD 1.75 GPM I � N �q� ♦ �J = I I � � • � WSE CREDIT 5c 1.5 credit HEAT PUMP HO TER TANK _ I � „ 60 MIN. WITH SELF � ( ) ELECTRIC IN WALL HEATER � 0 5 5-1/2 2 3 ; CLOSING HINGE � � BED # 2 = J I � N _ �� �r� N <9 ° CAPRET J I - O� N J �,♦ ,,♦ �.. � � N � I N � O � � 5O CFM � � • - _ • I W I � N � REMOVABLE VANITY � I ' - I O = NO CAB. UNDER SINK = I � r � ELECTRIC IN WALL HEATER N HOLE U N �. _ � ••-•• ••-••-••� 'H(7U5E N � �-I� _ � � = ALLOWING FORA �- I � _ � N cp FORWARD APPROACH I N J BED # 3 I �,. i - ,..� I �..-..�. N 0 _ �9 3�6�� � 3'2-1/2" 0 8'5-1/2" 4�6�� - - - - - -II � � \ I - - - _ CAPRET N I �.-..-�. °� II REMOVABLE\ � - _____________ ______� I w 3068 ;' r Q WSEC CREDIT 5a (.5 credits) � / V,%N ICY- -- I � • l\ I I U N II - -� � GROHE 2611700 FAIRBORN � � PARALLEL I `I -1/2" 2' � ° ° = SHOWER HEAD 1.75 GPM � �- .Lp,P�O.,c,E�1 N ---- - I � _ _ _ _ _ � _ _ _ _ _ _ �- �, � � I �t `� I 30"X48��"" I i--`----- ----' L-..-..-.! N I � TRITON BOWE BY KOHLER (FAUCET) •FLOORSPACE� K-SOOT70-4AKL-GP 1.0 GPM � �_- D � ° N r� �_ o -.� I I _ I� � H I I � -1/2" 2' " 8'4" � � I AVARTORY ° ST R N DUCTLESS INDOOR OO N o � j � � = o Z ¢; �,i � � I = y CAPRET � � UNIT LOCATION N o � � � � �_� �`I O IC � � � N 3068 3068 � � � � \ e THT j = I II LO � OPTION#1: INTERMITTENT WHOLE HOUSE VENTILATION � �� Bl �TT'��"-"-" I _ I � �• I • C • I ALLOWING FORA ALL HABITABLE ROOMS WILL REQUIRE OUTDOOR AIR INLETS cp 30ro8 �- TILE ,�' I � - C9 ------------ - N B. UNDER SINK USING EXHAUST FANS&FRESH AIR INLET6.IMC 403.8.E I I P RUN TIME FACTOR 2 - 50% RUN TIME IN EACH 4-HOUR SEGMENT. �.. _�.i [� I I FORWARD APPROACH I � � X4 SHOW N I I I A � � 50 CFM I o I � _ � V�%LC. CAPRET � • � . ' 4' SH W V.T.O. II I N _ N MBED � � � II � I � � " :- O I I � r- � I----------- ----' C� I 'MBED � i i � CAPRET � j II CAPRET o � I I � U I I 50 CFM TYP I� �I I I I � ' 2468 PD. I 24681'D. • , I------------------ ----JI � � z - -1/2" 1�8�� I _ I n �� - 44" MAX SILL HEIGHT I N I N � N I � N _ I o � III � MBATH � III I II N TILE I I-------- --- ----� I - �O N II � �- I N TYP ° � � I -- G � . , 44" MAX SILL HEIG T �- I N I ' - - - - - - - - -I 6' 6' 1'8-1/2' 4'3-1/2" 6'6" '6" 8' 2' 2' 2' 2' 1 1 6' 1 10' 7' 68' WSEC CREDIT 5a (.5 credits) TY " " TYPE "B" GROHE 2611700 FAIRBORN BATHROOM PER ICC 1004.11.3 SHOWER HEAD 1.75 GPM ONE BATHING FACILITY THAT IS ON AN ACCESSIBLE ROUTE 15 REQUIRED TO COMFY WITH OPTION "B" PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS WATER CLOSET, LAVATORY, AND BATHTUB TRITON BOWE BY KOHLER (FAUCET) K-SOOT70-4AKL-GP 1.0 GPM PE B BATHROOM PER ICC 1004.11.3 ONE BATHING FACILITY THAT IS ON AN ACCESSIBLE ROUTE IS REQUIRED TO COMFY WITH OPTION "B" PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS WATER CLOSET, LAVATORY, AND BATHTUB � 2X6 @ 16" O.G. STUD WALL W/ R-21 INSUL. ® (2)2X4 @ 16" O.C.,1" AIR SPACE � 1 HR METAL STUD WALL (AFTER ELEV. INSTALL) 0 2X4 @ 16" O.C. � 2X6 @ 16" O.G. � WOOD COLUMN OA PROVIDE OUTSIDE AIR FOR FURN. &WATER HEATER (RELIEF MUST VENT TO OUTSIDE (NOT GARAGE) I`�,'I 22"X30" ATTIC ACCESS (30" MIN. VERT. CLEARANCE I �� I WEATHERSTRIP & INSUL. TO R-49 V_ _J � "NO EXIT' SIGN O 120V SMK DET W/BATT BACKUP (INTERCONNECTED) ■ FIRE DETECTOR INTERCONNECTED EMERGENCY LIGHTING W/BATT BACKUP '■�' INDICATES ILLUMINATED EXIT SIGNS Wl BATT BACKUP GONTORL JOINTS BARRIER FREE DIRECTIONAL 51GNAGE LOCATION FUTURE GRAB BARS: PROVIDE BLOCKING ® HORIZONTAL CENTERLINE POSTION = 35" FROM FLOOR PER ICC/ANSI 609.4 CARBON MONOXIDE DETECTOR PER IRC 315 ALL UNITS ARE TO BE TYPE "B" UNITIS PER ICC-ANSI A117-1 SECTION 1004. INSTALL SOLID 2X BLOCKING FOR FURTURE GRAB BARS IN ALL BATHROOMS CLEAR FLOORS AREAS ARE INDICATED IN THE TYPE "B" BATHROOMS AND KITCHEN CERTIFICATE WILL BE POSTED IN FURNACE (OR OTHER APPROVED AREA) WITH THE FOLLOWING INFORMATION: R-VLAUNES, U-VALUES,RESULTS FROM DUCT SYSTEM TEST AIR LEAKAGE TESTING, RESULTS FROM BUIDLING ENCELOPE AIR LEAKAGE TESTING, TYPES AND EFFICIENCIES OF HEATING, COOLING ,AND SERVICE WATER HEATING EQUIPMENT PER R401.3 DUCTS ARE REQUIRED TO BE INSULATED TO A MINIMUM OF R-8 PER R403.3.1 THE DWELLING 15 REQUIRED TO BE TESTED &VERIFIED A5 HAVING AN AIR LEAKAGE RATE NOT EXCEEDING 3 AIR CHANGES PER HOUR PER R402.4.1 MECHANICAL DUCTS ARE REQUIRED TO BE SEAL TESTED IN ACCORDANCE WITH 403.3.2 TESTING TO COMPLY WITH WSU R5-33. EXTERIOR HEADERS ARE REQUIRED TO BE INSULATED WITH A MIN. OF R-10 INSULATION. CORNERS OF STUD WALLS ARE REQUIRED TO BE FULLY INSULATED. MECHANICAL SYSTEM PIPING ISOLATED MIN. R-6 PER R403.4 t ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ , I � 'This plan sheet has been approved for the Mechanical permit only. Any other notes or 'details found on this plan sheet to be referred to the approved Building permit plan set. ■ ELEVATOR EQUIPMENT ROOM •135° HEAT DETECTOR @SPRINKLER HEADS •PROVIDE FRESH AIR THROUGH 4" DUCT •EXAUST FAN TO MAINTAIN A MAX. TEMP. OF 90° & VENT TO OUTSIDE A5 REO'D BY MFG SPECS ELEVATOR NOTES •UNHEATED SPACE•CONTINOUS RIM @FLOORS. •INSTALLATION OF ADDITIONAL ELEVATOR DOORS SHALL NOT VIOLATE LISTINGS OF ELEVATOR (TYP) MECHANICAL CHASES •CONTINUOUS RIM @FLOOR. SPRINKLER ROOM •FIRE ALARM CONROL PANEL IN SPRINKLER ROOM W/ CENTRAL STATION SERVICE MONITORING •ANNUNCIATOR IN LOBBY STAIR NOTES •MAINTAIN REO'D 1 HR STAIRS ENCLOU5URE5 &MIN 6'-8" HEADROOM @STAIRS •ELECTRIC HEAT 40 MIN.TEMP 1 WATT PER 50. FT UNHEATED SPACE •STAIR BACKING FOR HAND RAIL •CONTINUOUS RIM @FLOOR. •BASEMENT STAIR: RISE = 6.81" RUN = 11" ALL OTHER STAIRS: RISE = 6.72" FIREPLACE NOTES •'D' CLEARANCE FIREPLACE W/ DIRECT VENT FACTORY BUILT FIREPLCE SHALL BE INSTALLED PER MANUFACTURER'S SPECS AND SHALL HAVE APPROAL LABEL ATTACHED 15/8" TYPE "X" GWB TO ROOF SHEATING FIREPLACES &STOVES MUST BE D.O.E CERTIFIED &LABELED AS SUITABLE FOR USE DURING A FIRST STAGE BURN BAN. (Tj« PROVIDE ONE OPENABLE ESCAPE WINDOW IN BASEMENT & IN EACH SLEEPING ROOM MEETING ALL THE FOLLOWING REQUIREMENTS: 1. AN OPENABLE AREA OF NOT LESS THEN 5.7 SO.FT. 2. A MIN. CLEAR HEIGHT OF 24" 3. A MIN. CLEAR WIDTH OF 20" 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FINISH FLOOR. 5. ALL WINDOWS TO INCLUDE FRESH AIR VENTS OR METERED FRESH AIR SUPPLY @FURNACE 6.ALL WINDOWS &DOORS HAVING ACCESS TO EXTERIOR OR UNHEATED TO BE SEALED PER SEC. 402.4.1.1(WAC) • RECESSED LIGHTING TO BE IC RATED • ALL TYPE "B" DECK SURFACES TO BE NO MORE THAN 4" BELOW INTERIOR FLOOR LEVEL •ALL TYPE "B" FRONT DOORS TO BE 2'-10" MIN. &ALL DOOR THRESHOLDS CANNOT EXCEED 1/2" PER 404 •ALL DWELLINGS MUST BE TYPE B ,OPT. B •ALL REQUIRED DOOR HARDWARE TO MEET IBC CHAPTER 11 & EXITING PER 1010.1.9.1 IMC TYPE B OR L VENT CONNECTORS REO'D ON FUEL -BURNING APPLIANCE IN UNHEATED SPACES HYDRONIC HEATING SYSTEM APPROVAL BY THE WATER SURVEYOR DOES NOT RELIEVE THE CUSTOMER OF THE RESPONSIBLITY TO COMPLY W/ THE REQUIREMENTS OF OTHER AGENCIES HAVING JURISDICTION. APPROVAL OF TH15 PLAN DOES NOT VEST THE BUILDING OR PLUMBING SINCE FUTURE CHANGES IN THE CUSTOMERS WATER USE MAY INCREASE THE ASSE55MENT RISK &THE SURVEYORS PROTECTION REQUIREMENTS. IMC. CHAPTER 12 BUILDING INSPECTORS MUST OBSERVE A HYDROSTATIC TEST ON THE HOT WATER SUPPLY LINES &THE PANEL SYSTEM. •TEST:100 PSI WATER PRESSURE OR 1-1/2 TIMES THE OPERATING PRESSURE, WHICHEVER IS GREATER. MIN 30 MINUTES TEST. •PIPING EMBEDDED IN CONCRETE MUST BE PRESSURE TESTED PRIOR TO POURING OF CONCRETE AND BE MAINTAINED DURING PLACEMENT. • GARAGE HEADROOM TO BE MIN. OF 7'-0" CLEARANCE FROM ALL PIPES, SPRINKLER HEADS, DUCTS, BEAMS, & INSULATION, ETC. •MIN. HEADROOM CLEARANCE OF 7'-6" IS REQ'D IN ALL HABITAL SPACES, & 7'-0" IS REO'D ELSEWHERE •LOCATION OF EMERGENCY LIGHTING SHALL BE APPROVED BY FIRE MARSHAL •REQ'D WHEEL STOP @ALL PARKING STALLS •EXHAUST OUTLETS TO BE A MIN. OF 3'-0" FROM BUILDING OPENINGS & 10'-0" FROM SUPPLY AIR INLETS (TYP). •DOUBLE GHEGK VALVE INSPECTION REO'D BY CITY CROSS CONNECTION CONTROL SPECIALIST PRIOR TO HYDRO STATIC TEST OF FIRE SPRINKLER SYSTEM. • ACCESS TO DOUBLE CHECK VALVE MUST BE WITHIN 5' ABOVE FINISHED FLOOR OR A 30"X30" MIN PLATFORM MUST BE INSTALLED FOR ACCESS •WALLS SEPARATING DWELLING UNITS FROM COMMON AREAS (STAIR ENCLOSURES, ELEVATOR SHAFT, ETC) MUST HAVE AN STC OF 50 OR MORE •SMOKE &DRAFT -ASSEMBLIES IN LOBBY,1-HR AREAS & ELEVATORS/ ENTRY LOCATIONS SHALL HAVE A FIRE PROTECTION RATING OF NOT LESS THAN 50 MIN. &BEAR AN APPROVED LABEL IDENTIFING THE RATING OF THE ASSEMBLY FOLLOWED BY THE LETTER "S". DOORS SHALL BE MAINTAINED SELF -CLOSING OR BE AUTOMATIC CLOSING BY ACTIVATION OF A SMOKE DETECTOR ADDITIONAL PLUMBING REQUIREMENTS: •MAIN BUILDING SHUT-OFF REO'D ON WATER SUPPLY LINE. •PRESSURE REDUCTION VALVE ON MAIN WATER SUPPLY LINE REO'D BY CITY CODE •EXPANSION TANK REQ'D ON EACH HOT WATER TANK. •VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO THE OUTSIDE •HOT WATER HEATER MUST BE 5E15MIGALLY ANCHORED OR STRAPPED @POINTS WITHIN THE UPPER 1/3 &LOWER 1/3 OF ITS VERTICAL DIMENSION. @THE LOWER POINT, A MIN. DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS W/ THE STRAPPING •PROIVIDE INDIVIDUAL SHUTOFFS FOR EACH UNIT •1" AIRGAP REQ'D ON DISHWAHSHER •ALL SHOWERS HEADS TO BE EQUIPPED WITH FLOW CONTROL DEVICE TO LIMIT FLOW T01.75 GPM •AIR SWITCH FOR DISPOSAL IN SINK •ALL HOTWATER PIPES MUST BE INSULATED WITH R-3 INSULATION PER 2015 WSEC SEC 403.5.3. SCALE: 1 /4" =1'-0" 301: LIV=1,795.08 SQ. FT. DECK=175.88SQ. FT. 302: LIV=1,442.75 SQ. FT. DECK=114.25 SQ. FT COMMON AREA: 215.79 SQ. FT. TOTAL = 3,453.62 z c� W Q z 0 u 0 a i z� 0 �� �� W� �Q �z 0 �Q �W ................ REVISIONS: 7.21.20 10.16.20 2.6.23 5.2.23 5.2.23